Skip to contentSkip to conversation

Read from the first device when an area is resyncing

PATCH In review Goldwyn Rodrigues 1 participant 1 message Dec 18, 2014 MD RAID

lore
Share & tools
lore
#0 lore raw

PATCH 23/24 Read from the first device when an area is resyncing

set choose_first true for cluster read in read balance when the area is resyncing.

---
 drivers/md/raid1.c | 8 +++++++-
 1 file changed, 7 insertions(+), 1 deletion(-)
drivers/md/raid1.c +7 -1
index eb8fd2e..4dcbaae 100644
@@ -540,7 +540,13 @@ static int read_balance(struct r1conf *conf, struct r1bio *r1_bio, int *max_sect
 	has_nonrot_disk = 0;
 	choose_next_idle = 0;
 
-	choose_first = (conf->mddev->recovery_cp < this_sector + sectors);
+	if ((conf->mddev->recovery_cp < this_sector + sectors) ||
+	    (mddev_is_clustered(conf->mddev) &&
+	    md_cluster_ops->area_resyncing(conf->mddev, this_sector,
+		    this_sector + sectors)))
+		choose_first = 1;
+	else
+		choose_first = 0;
 
 	for (disk = 0 ; disk < conf->raid_disks * 2 ; disk++) {
 		sector_t dist;
Signature · 1 line
2.1.2