Ethernet PHY Power Down
I have run into an issue with a KSZ9031 Gigabit Ethernet PHY on an IMX6 module.
After booting into Linux and rebooting the ethernet fails consistently.
With a bit of investigation I found that the power-down bit in the PHY control register is being set on reboot.
=> dhcp
BOOTP broadcast 1
BOOTP broadcast 2
BOOTP broadcast 3
BOOTP broadcast 4
BOOTP broadcast 5
.
.
Abort
=> mii dump 1 0
0. (1940) -- PHY control register --
(8000:0000) 0.15 = 0 reset (4000:0000) 0.14 = 0 loopback (2040:0040) 0. 6,13 = b10 speed selection = 1000 Mbps (1000:1000) 0.12 = 1 A/N enable (0800:0800) 0.11 = 1 power-down (0400:0000) 0.10 = 0 isolate (0200:0000) 0. 9 = 0 restart A/N (0100:0100) 0. 8 = 1 duplex = full (0080:0000) 0. 7 = 0 collision test enable (003f:0000) 0. 5- 0 = 0 (reserved)
When I manually toggle the power down bit it starts to work again.
=> mii write 1 0 1140
=> dhcp
FEC Waiting for PHY auto negotiation to complete........ done BOOTP broadcast 1
DHCP client bound to address 192.168.0.12 (62 ms)
I tried performing the above steps in the PHY driver code with little luck. When I toggle the bit in the code the first dhcp always fails but then it works on subsequent attempts.
Any ideas?