Add vNVDIMM support for Xen
Hi,
The following document describes the design of adding vNVDIMM support for Xen. Any comments are welcome.
Thanks,
Haozhong
Content
=======
1. Background
1.1 Access Mechanisms: Persistent Memory and Block Window 1.2 ACPI Support
1.2.1 NFIT
1.2.2 _DSM and _FIT
1.3 Namespace
1.4 clwb/clflushopt/pcommit
2. NVDIMM/vNVDIMM Support in Linux Kernel/KVM/QEMU 2.1 NVDIMM Driver in Linux Kernel
2.2 vNVDIMM Implementation in KVM/QEMU
3. Design of vNVDIMM in Xen
3.1 Guest clwb/clflushopt/pcommit Enabling
3.2 Address Mapping
3.2.1 My Design
3.2.2 Alternative Design
3.3 Guest ACPI Emulation
3.3.1 My Design
3.3.2 Alternative Design 1: switching to QEMU 3.3.3 Alternative Design 2: keeping in Xen
References
Non-Volatile DIMM or NVDIMM is a type of RAM device that provides persistent storage and retains data across reboot and even power failures. This document describes the design to support virtual NVDIMM devices or vNVDIMM in Xen.
The rest of this document is organized as below.
- Section 1 briefly introduces the background knowledge of NVDIMM hardware, which is used by other parts of this document.
- Section 2 briefly introduces the current/future NVDIMM/vNVDIMM support in Linux kernel/KVM/QEMU. They will affect the vNVDIMM design in Xen.
- Section 3 proposes design details of vNVDIMM in Xen. Several alternatives are also listed in this section.
1. Background
1.1 Access Mechanisms: Persistent Memory and Block Window
NVDIMM provides two access mechanisms: byte-addressable persistent memory (pmem) and block window (pblk). An NVDIMM can contain multiple ranges and each range can be accessed through either pmem or pblk (but not both).
Byte-addressable persistent memory mechanism (pmem) maps NVDIMM or ranges of NVDIMM into the system physical address (SPA) space, so that software can access NVDIMM via normal memory loads and stores. If the virtual address is used, then MMU will translate it to the physical address.
In the virtualization circumstance, we can pass through a pmem range or partial of it to a guest by mapping it in EPT (i.e. mapping guest vNVDIMM physical address to host NVDIMM physical address), so that guest accesses are applied directly to the host NVDIMM device without hypervisor's interceptions.
Block window mechanism (pblk) provides one or multiple block windows (BW). Each BW is composed of a command register, a status register and a 8 Kbytes aperture register. Software fills the direction of the transfer (read/write), the start address (LBA) and size on NVDIMM it is going to transfer. If nothing goes wrong, the transferred data can be read/write via the aperture register. The status and errors of the transfer can be got from the status register. Other vendor-specific commands and status can be implemented for BW as well. Details of the block window access mechanism can be found in [3].
In the virtualization circumstance, different pblk regions on a single NVDIMM device may be accessed by different guests, so the hypervisor needs to emulate BW, which would introduce a high overhead for I/O intensive workload.
Therefore, we are going to only implement pmem for vNVDIMM. The rest of this document will mostly concentrate on pmem.
1.2 ACPI Support
ACPI provides two factors of support for NVDIMM. First, NVDIMM devices are described by firmware (BIOS/EFI) to OS via ACPI-defined NVDIMM Firmware Interface Table (NFIT). Second, several functions of NVDIMM, including operations on namespace labels, S.M.A.R.T and hotplug, are provided by ACPI methods (_DSM and _FIT).
1.2.1 NFIT
NFIT is a new system description table added in ACPI v6 with signature "NFIT". It contains a set of structures.
- System Physical Address Range Structure
(SPA Range Structure)
SPA range structure describes system physical address ranges occupied by NVDIMMs and types of regions.
If Address Range Type GUID field of a SPA range structure is "Byte Addressable Persistent Memory (PM) Region", then the structure describes a NVDIMM region that is accessed via pmem. The System Physical Address Range Base and Length fields describe the start system physical address and the length that is occupied by that NVDIMM region.
A SPA range structure is identified by a non-zero SPA range structure index.
Note: [1] reserves E820 type 7: OSPM must comprehend this memory as
having non-volatile attributes and handle distinct from conventional volatile memory (in Table 15-312 of [1]). The memory region supports byte-addressable non-volatility. E820 type 12 (OEM defined) may be also used for legacy NVDIMM prior to ACPI v6.
Note: Besides OS, EFI firmware may also parse NFIT for booting
drives (Section 9.3.6.9 of [5]).
- Memory Device to System Physical Address Range Mapping Structure (Range Mapping Structure)
An NVDIMM region described by a SPA range structure can be interleaved across multiple NVDIMM devices. A range mapping structure is used to describe the single mapping on each NVDIMM device. It describes the size and the offset in a SPA range that an NVDIMM device occupies. It may refer to an Interleave Structure that contains details of the entire interleave set. Those information is used in pblk by the NVDIMM driver for address translation.
The NVDIMM device described by the range mapping structure is identified by an unique NFIT Device Handle.
Details of NFIT and other structures can be found in Section 5.25 in [1].
1.2.2 _DSM and _FIT
The ACPI namespace device uses _HID of ACPI0012 to identify the root NVDIMM interface device. An ACPI namespace device is also present under the root device For each NVDIMM device. Above ACPI namespace devices are defined in SSDT.
_DSM methods are present under the root device and each NVDIMM device. _DSM methods are used by drivers to access the label storage area, get health information, perform vendor-specific commands, etc. Details of all _DSM methods can be found in [4].
_FIT method is under the root device and evaluated by OSPM to get NFIT of hotplugged NVDIMM. The hotplugged NVDIMM is indicated to OS using ACPI Namespace device with PNPID of PNP0C80 and the device object notification value is 0x80. Details of NVDIMM hotplug can be found in Section 9.20 of [1].
1.3 Namespace
[2] describes a mechanism to sub-divide NVDIMMs into namespaces, which are logic units of storage similar to SCSI LUNs and NVM Express namespaces.
The namespace information is describes by namespace labels stored in the persistent label storage area on each NVDIMM device. The label storage area is excluded from the the range mapped by the SPA range structure and can only be accessed via _DSM methods.
There are two types of namespaces defined in [2]: the persistent memory namespace and the block namespaces. Persistent memory namespaces is built for only pmem NVDIMM regions, while block namespaces only for pblk. Only one persistent memory namespace is allowed for a pmem NVDIMM region.
Besides being accessed via _DSM, namespaces are managed and interpreted by software. OS vendors may decide to not follow [2] and store other types of information in the label storage area.
1.4 clwb/clflushopt/pcommit
Writes to NVDIMM may be cached by caches, so certain flushing operations should be performed to make them persistent on NVDIMM. clwb is used in favor of clflushopt and clflush to flush writes from caches to memory. Then a following pcommit makes them finally persistent (power failure protected) on NVDIMM.
Details of clwb/clflushopt/pcommit can be found in Chapter 10 of [6].
2. NVDIMM/vNVDIMM Support in Linux Kernel/KVM/QEMU
2.1 NVDIMM Driver in Linux Kernel
Linux kernel since 4.2 has added support for ACPI-defined NVDIMM devices.
NVDIMM driver in Linux probes NVDIMM devices through ACPI (i.e. NFIT and _FIT). It is also responsible to parse the namsepace labels on each NVDIMM devices, recover namespace after power failure (as described in [2]) and handle NVDIMM hotplug. There are also some vendor drivers to perform vendor-specific operations on NVDIMMs (e.g. via _DSM).
Compared to the ordinary ram, NVDIMM is used more like a persistent storage drive for its persistent aspect. For each persistent memory namespace, or a label-less pmem NVDIMM range, NVDIMM driver implements a block device interface (/dev/pmemX) for it.
Userspace applications can mmap(2) the whole pmem into its own virtual address space. Linux kernel maps the system physical address space range occupied by pmem into the virtual address space, so that every normal memory loads/writes with proper flushing instructions are applied to the underlying pmem NVDIMM regions.
Alternatively, a DAX file system can be made on /dev/pmemX. Files on that file system can be used in the same way as above. As Linux kernel maps the system address space range occupied by those files on NVDIMM to the virtual address space, reads/writes on those files are applied to the underlying NVDIMM regions as well.
2.2 vNVDIMM Implementation in KVM/QEMU
An overview of vNVDIMM implementation in KVM (Linux kernel v4.2) / QEMU (commit 70d1fb9 and patches in-review/future) is showed by the following figure.
+---------------------------------+
Guest GPA | | /dev/pmem0 |
+---------------------------------+
parse evaluate ^ ^
ACPI _DSM | |
| | | |
-------------|------------|--------------------------------|------------|----
V V | |
+-------+ +-------+ | |
QEMU | vACPI | | v_DSM | | |
+-------+ +-------+ | |
^ | |
| Read/Write | |
V | |
+...+--------------------+...+-----------+ | |
VA | | Label Storage Area | | buf | KVM_SET_USER_MEMORY_REGION(buf)
+...+--------------------+...+-----------+ | |
^ mmap(2) ^ | |
--------------------------------------|-----------|--------|------------|----
| +--------~------------+
| | |
Linux/KVM +--------------------+ |
| |
+....+------------+
SPA | | /dev/pmem0 |
+....+------------+
^
|
Host NVDIMM Driver
-------------------------------------------------------------------|---------
|
HW +------------+
| NVDIMM |
+------------+A part not put in above figure is enabling guest clwb/clflushopt/pcommit which exposes those instructions to guest via guest cpuid.
Besides instruction enabling, there are two primary parts of vNVDIMM implementation in KVM/QEMU.
(1) Address Mapping
As described before, the host Linux NVDIMM driver provides a block device interface (/dev/pmem0 at the bottom) for a pmem NVDIMM region. QEMU can than mmap(2) that device into its virtual address space (buf). QEMU is responsible to find a proper guest physical address space range that is large enough to hold /dev/pmem0. Then QEMU passes the virtual address of mmapped buf to a KVM API KVM_SET_USER_MEMORY_REGION that maps in EPT the host physical address range of buf to the guest physical address space range where the virtual pmem device will be.
In this way, all guest writes/reads on the virtual pmem device is applied directly to the host one.
Besides, above implementation also allows to back a virtual pmem device by a mmapped regular file or a piece of ordinary ram.
(2) Guest ACPI Emulation
As guest system physical address and the size of the virtual pmem device are determined by QEMU, QEMU is responsible to emulate the guest NFIT and SSDT. Basically, it builds the guest NFIT and its sub-structures that describes the virtual NVDIMM topology, and a guest SSDT that defines ACPI namespace devices of virtual NVDIMM in guest SSDT.
As a portion of host pmem device or a regular file/ordinary file can be used to back the guest pmem device, the label storage area on host pmem cannot always be passed through to guest. Therefore, the guest reads/writes on the label storage area is emulated by QEMU. As described before, _DSM method is utilized by OSPM to access the label storage area, and therefore it is emulated by QEMU. The _DSM buffer is registered as MMIO, and its guest physical address and size are described in the guest ACPI. Every command/status read/write from guest is trapped and emulated by QEMU.
Guest _FIT method will be implemented similarly in the future.
3. Design of vNVDIMM in Xen
Similarly to that in KVM/QEMU, enabling vNVDIMM in Xen is composed of three parts:
(1) Guest clwb/clflushopt/pcommit enabling,
(2) Memory mapping, and
(3) Guest ACPI emulation.
The rest of this section present the design of each part respectively. The basic design principle to reuse existing code in Linux NVDIMM driver and QEMU as much as possible. As recent discussions in the both Xen and QEMU mailing lists for the v1 patch series, alternative designs are also listed below.
3.1 Guest clwb/clflushopt/pcommit Enabling
The instruction enabling is simple and we do the same work as in KVM/QEMU.
- All three instructions are exposed to guest via guest cpuid.
- L1 guest pcommit is never intercepted by Xen.
- L1 hypervisor is allowed to intercept L2 guest pcommit.
3.2 Address Mapping
3.2.1 My Design
The overview of this design is shown in the following figure.
Dom0 | DomU
|
|
QEMU |
+...+--------------------+...+-----+ |
VA | | Label Storage Area | | buf | |
+...+--------------------+...+-----+ |
^ ^ ^ |
| | | |
V | | |
+-------+ +-------+ mmap(2) |
| vACPI | | v_DSM | | | | +----+------------+
+-------+ +-------+ | | | SPA | | /dev/pmem0 |
^ ^ +------+ | | +----+------------+
--------|-----------|-----|------------|-- | ^ ^
| | | | | | |
| +------+ +------------~-----~-------------+ |
| | | | | XEN_DOMCTL_memory_mapping
| | | +-----~--------------------------+
| | | | |
| | +----+------------+ |
Linux | | SPA | | /dev/pmem0 | | +------+ +------+
| | +----+------------+ | | ACPI | | _DSM |
| | ^ | +------+ +------+
| | | | | |
| | Dom0 Driver | hvmloader/xl |
--------|----|-------------------|---------------------|----------|---------------
| +-------------------~---------------------~----------+
Xen | | |
+------------------------~---------------------+
---------------------------------|------------------------------------------------
+----------------+
|
+-------------+
HW | NVDIMM |
+-------------+ This design treats host NVDIMM devices as ordinary MMIO devices:
(1) Dom0 Linux NVDIMM driver is responsible to detect (through NFIT) and drive host NVDIMM devices (implementing block device interface). Namespaces and file systems on host NVDIMM devices are handled by Dom0 Linux as well.
(2) QEMU mmap(2) the pmem NVDIMM devices (/dev/pmem0) into its virtual address space (buf).
(3) QEMU gets the host physical address of buf, i.e. the host system physical address that is occupied by /dev/pmem0, and calls Xen hypercall XEN_DOMCTL_memory_mapping to map it to a DomU.
(ACPI part is described in Section 3.3 later)
Above (1)(2) have already been done in current QEMU. Only (3) is needed to implement in QEMU. No change is needed in Xen for address mapping in this design.
Open: It seems no system call/ioctl is provided by Linux kernel to
get the physical address from a virtual address. /proc/<qemu_pid>/pagemap provides information of mapping from VA to PA. Is it an acceptable solution to let QEMU parse this file to get the physical address?
Open: For a large pmem, mmap(2) is very possible to not map all SPA
occupied by pmem at the beginning, i.e. QEMU may not be able to get all SPA of pmem from buf (in virtual address space) when calling XEN_DOMCTL_memory_mapping.
Can mmap flag MAP_LOCKED or mlock(2) be used to enforce the entire pmem being mmaped?
3.2.2 Alternative Design
Jan Beulich's comments [7] on my question "why must pmem resource management and partition be done in hypervisor":
| Because that's where memory management belongs. And PMEM, | other than PBLK, is just another form of RAM. | ... | The main issue is that this would imo be a layering violation
George Dunlap's comments [8]:
| This is not the case for PMEM. The whole point of PMEM (correct me if
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ used as fungible ram
| I'm wrong) is to be used for long-term storage that survives over | reboot. It matters very much that a guest be given the same PRAM | after the host is rebooted that it was given before. It doesn't make | any sense to manage it the way Xen currently manages RAM (i.e., that | you request a page and get whatever Xen happens to give you). | | So if Xen is going to use PMEM, it will have to invent an entirely new | interface for guests, and it will have to keep track of those | resources across host reboots. In other words, it will have to | duplicate all the work that Linux already does. What do we gain from | that duplication? Why not just leverage what's already implemented in | dom0? and [9]: | Oh, right -- yes, if the usage model of PRAM is just "cheap slow RAM", | then you're right -- it is just another form of RAM, that should be | treated no differently than say, lowmem: a fungible resource that can be | requested by setting a flag.
However, pmem is used more as persistent storage than fungible ram, and my design is for the former usage. I would like to leave the detection, driver and partition (either through namespace or file systems) of NVDIMM in Dom0 Linux kernel.
I notice that current XEN_DOMCTL_memory_mapping does not make santiy check for the physical address and size passed from caller (QEMU). Can QEMU be always trusted? If not, we would need to make Xen aware of the SPA range of pmem so that it can refuse map physical address in neither the normal ram nor pmem.
Instead of duplicating the detection code (parsing NFIT and evaluating _FIT) in Dom0 Linux kernel, we decide to patch Dom0 Linux kernel to pass parameters of host pmem NVDIMM devices to Xen hypervisor:
(1) Add a global
struct rangeset pmem_rangeset
in Xen hypervisor to record all SPA ranges of detected pmem devices. Each range in pmem_rangeset corresponds to a pmem device.
(2) Add a hypercall
XEN_SYSCTL_add_pmem_range
(should it be a sysctl or a platform op?)
that receives a pair of parameters (addr: starting SPA of pmem region, len: size of pmem region) and add a range (addr, addr + len - 1) in nvdimm_rangset.
(3) Add a hypercall
XEN_DOMCTL_pmem_mapping
that takes the same parameters as XEN_DOMCTL_memory_mapping and maps a given host pmem range to guest. It checks whether the given host pmem range is in the pmem_rangeset before making the actual mapping.
(4) Patch Linux NVDIMM driver to call XEN_SYSCTL_add_pmem_range whenever it detects a pmem device.
(5) Patch QEMU to use XEN_DOMCTL_pmem_mapping for mapping host pmem devices.
3.3 Guest ACPI Emulation
3.3.1 My Design
Guest ACPI emulation is composed of two parts: building guest NFIT and SSDT that defines ACPI namespace devices for NVDIMM, and emulating guest _DSM.
(1) Building Guest ACPI Tables
This design reuses and extends hvmloader's existing mechanism that loads passthrough ACPI tables from binary files to load NFIT and SSDT tables built by QEMU:
1) Because the current QEMU does not building any ACPI tables when it runs as the Xen device model, this design needs to patch QEMU to build NFIT and SSDT (so far only NFIT and SSDT) in this case.
2) QEMU copies NFIT and SSDT to the end of guest memory below 4G. The guest address and size of those tables are written into xenstore (/local/domain/domid/hvmloader/dm-acpi/{address,length}).
3) hvmloader is patched to probe and load device model passthrough ACPI tables from above xenstore keys. The detected ACPI tables are then appended to the end of existing guest ACPI tables just like what current construct_passthrough_tables() does.
Reasons for this design are listed below:
- NFIT and SSDT in question are quite self-contained, i.e. they do not refer to other ACPI tables and not conflict with existing guest ACPI tables in Xen. Therefore, it is safe to copy them from QEMU and append to existing guest ACPI tables.
- A primary portion of current and future vNVDIMM implementation is about building ACPI tables. And this design also leave the emulation of _DSM to QEMU which needs to keep consistency with NFIT and SSDT itself builds. Therefore, reusing NFIT and SSDT from QEMU can ease the maintenance.
- Anthony's work to pass ACPI tables from the toolstack to hvmloader does not move building SSDT (and NFIT) to toolstack, so this design can still put them in hvmloader.
(2) Emulating Guest _DSM
Because the same NFIT and SSDT are used, we can leave the emulation of guest _DSM to QEMU. Just as what it does with KVM, QEMU registers the _DSM buffer as MMIO region with Xen and then all guest evaluations of _DSM are trapped and emulated by QEMU.
3.3.2 Alternative Design 1: switching to QEMU
Stefano Stabellini's comments [10]:
| I don't think it is wise to have two components which both think are | in control of generating ACPI tables, hvmloader (soon to be the | toolstack with Anthony's work) and QEMU. From an architectural | perspective, it doesn't look robust to me. | | Could we take this opportunity to switch to QEMU generating the whole | set of ACPI tables?
So an alternative design could be switching to QEMU to generate the whole set of guest ACPI tables. In this way, no controversy would happen between multiple agents QEMU and hvmloader. (is this what Stefano Stabellini mean by 'robust'?)
However, looking at the code building ACPI tables in QEMU and hvmloader, they are quite different. As ACPI tables are important for OS to boot and operate device, it's critical to ensure ACPI tables built by QEMU would not break existing guests on Xen. Though I believe it could be done after a thorough investigation and adjustment, it may take quite a lot of work and tests and should be another project besides enabling vNVDIMM in Xen.
3.3.3 Alternative Design 2: keeping in Xen
Alternative to switching to QEMU, another design would be building NFIT and SSDT in hvmloader or toolstack.
The amount and parameters of sub-structures in guest NFIT vary according to different vNVDIMM configurations that can not be decided at compile-time. In contrast, current hvmloader and toolstack can only build static ACPI tables, i.e. their contents are decided statically at compile-time and independent from the guest configuration. In order to build guest NFIT at runtime, this design may take following steps:
(1) xl converts NVDIMM configurations in xl.cfg to corresponding QEMU options,
(2) QEMU accepts above options, figures out the start SPA range address/size/NVDIMM device handles/..., and writes them in xenstore. No ACPI table is built by QEMU.
(3) Either xl or hvmloader reads above parameters from xenstore and builds the NFIT table.
For guest SSDT, it would take more work. The ACPI namespace devices are defined in SSDT by AML, so an AML builder would be needed to generate those definitions at runtime.
This alternative design still needs more work than the first design.
References:
[1] ACPI Specification v6,
http://www.uefi.org/sites/default/files/resources/ACPI_6.0.pdf
[2] NVDIMM Namespace Specification,
http://pmem.io/documents/NVDIMM_Namespace_Spec.pdf
[3] NVDIMM Block Window Driver Writer's Guide,
http://pmem.io/documents/NVDIMM_Driver_Writers_Guide.pdf
[4] NVDIMM DSM Interface Example,
http://pmem.io/documents/NVDIMM_DSM_Interface_Example.pdf
[5] UEFI Specification v2.6,
http://www.uefi.org/sites/default/files/resources/UEFI%20Spec%202_6.pdf [6] Intel Architecture Instruction Set Extensions Programming Reference, https://software.intel.com/sites/default/files/managed/07/b7/319433-023.pdf
[7] http://www.gossamer-threads.com/lists/xen/devel/414945#414945
[8] http://www.gossamer-threads.com/lists/xen/devel/415658#415658
[9] http://www.gossamer-threads.com/lists/xen/devel/415681#415681
[10] http://lists.xenproject.org/archives/html/xen-devel/2016-01/msg00271.html
Quoted 7 lines · Haozhong Zhang
Hi,
The following document describes the design of adding vNVDIMM support for Xen. Any comments are welcome.
Thanks,
Haozhong
Thankyou for doing this. It is a very comprehensive document, and a fantastic example for future similar situations.
To start with however, I would like to clear up my confusion over the the usecases of pmem vs pblk.
pblk, using indirect access, is less efficient than pmem. NVDIMMs themselves are slower (and presumably more expensive) than equivalent RAM, and presumably still has a finite number of write cycles, so I don't buy an argument suggesting that they are a plausible replacement for real RAM.
I presume therefore that a system would only choose to use pblk mode in situations where the host physical address space is a limiting factor. Are there other situations which I have overlooked?
Secondly, I presume that pmem vs pblk will be a firmware decision and fixed from the point of view of the Operating System?
Thanks,
~Andrew
Quoted 6 lines
From: Andrew Cooper [mailto:[email protected]]
Sent: Tuesday, February 02, 2016 2:25 AMQuoted 2 lines · Haozhong Zhang
Hi,
Quoted 8 lines
Quoted 5 lines
The following document describes the design of adding vNVDIMM support for Xen. Any comments are welcome.
Thanks,
HaozhongThankyou for doing this. It is a very comprehensive document, and a fantastic example for future similar situations.
Agree. It's a very good doc to help following discussions.
Quoted 10 lines
To start with however, I would like to clear up my confusion over the the usecases of pmem vs pblk.
pblk, using indirect access, is less efficient than pmem. NVDIMMs themselves are slower (and presumably more expensive) than equivalent RAM, and presumably still has a finite number of write cycles, so I don't buy an argument suggesting that they are a plausible replacement for real RAM.
for pblk, I think it's more meaningful to compare with today's SSD.
Quoted 4 lines
I presume therefore that a system would only choose to use pblk mode in situations where the host physical address space is a limiting factor. Are there other situations which I have overlooked?
I think you more mean RAM size limitation here. Today 48bit physical address space is not limiting yet. :-)
Quoted 4 lines
Secondly, I presume that pmem vs pblk will be a firmware decision and fixed from the point of view of the Operating System?
Yes from the description of ACPI manner.
Thanks
Kevin
Quoted 22 lines · Andrew Cooper
Quoted 7 lines · Haozhong Zhang
Hi,
The following document describes the design of adding vNVDIMM support for Xen. Any comments are welcome.
Thanks,
HaozhongThankyou for doing this. It is a very comprehensive document, and a fantastic example for future similar situations.
To start with however, I would like to clear up my confusion over the the usecases of pmem vs pblk.
pblk, using indirect access, is less efficient than pmem. NVDIMMs themselves are slower (and presumably more expensive) than equivalent RAM, and presumably still has a finite number of write cycles, so I don't buy an argument suggesting that they are a plausible replacement for real RAM.
Quoted 4 lines
I presume therefore that a system would only choose to use pblk mode in situations where the host physical address space is a limiting factor. Are there other situations which I have overlooked?
Limited physical address space is one concern. Another concern is that pblk can be used by drivers to provide better RAS, like better error detection and power-fail write atomicity. See Section "NVDIMM Driver" in Chapter 1 of [3] for more details.
Quoted 3 lines
Secondly, I presume that pmem vs pblk will be a firmware decision and fixed from the point of view of the Operating System?
Specifications on my hands [1-4] do not mention which one is in charge for partitioning NVDIMM into pmem and pblk. However, as NFIT uses separated SPA range structures for pmem and pblk regions, I also presume that firmware (BIOS/EFI, or firmware on NVDIMM devices) determines the partition.
In addition, some NVDIMM vendors may provide specific _DSM commands to allow software (OS/drivers) to reconfigure the pmem/pblk partition, but those changes only take effect after reboot. If OS/drivers or system administrators decide to do so, IMO they should make sure no users are currently using those NVDIMMs and data on NVDIMMs is already properly handled.
Haozhong
Quoted 22 lines · Haozhong Zhang
Quoted 21 lines · Andrew Cooper
Quoted 7 lines · Haozhong Zhang
Hi,
The following document describes the design of adding vNVDIMM support for Xen. Any comments are welcome.
Thanks,
HaozhongThankyou for doing this. It is a very comprehensive document, and a fantastic example for future similar situations.
To start with however, I would like to clear up my confusion over the the usecases of pmem vs pblk.
pblk, using indirect access, is less efficient than pmem. NVDIMMs themselves are slower (and presumably more expensive) than equivalent RAM, and presumably still has a finite number of write cycles, so I don't buy an argument suggesting that they are a plausible replacement for real RAM.
Quoted 8 lines
Quoted 4 lines
I presume therefore that a system would only choose to use pblk mode in situations where the host physical address space is a limiting factor. Are there other situations which I have overlooked?
Limited physical address space is one concern. Another concern is that pblk can be used by drivers to provide better RAS, like better error detection and power-fail write atomicity. See Section "NVDIMM Driver" in Chapter 1 of [3] for more details.
Ah ok. So even with no limiting factors to consider, it would be a plausible design choice to use it in pblk mode.
Quoted 10 lines
Quoted 4 lines
Secondly, I presume that pmem vs pblk will be a firmware decision and fixed from the point of view of the Operating System?
Specifications on my hands [1-4] do not mention which one is in charge for partitioning NVDIMM into pmem and pblk. However, as NFIT uses separated SPA range structures for pmem and pblk regions, I also presume that firmware (BIOS/EFI, or firmware on NVDIMM devices) determines the partition.
Quoted 6 lines
In addition, some NVDIMM vendors may provide specific
_DSMcommands to allow software (OS/drivers) to reconfigure the pmem/pblk partition, but those changes only take effect after reboot. If OS/drivers or system administrators decide to do so, IMO they should make sure no users are currently using those NVDIMMs and data on NVDIMMs is already properly handled.
Ok. Either way, it is going to be an administrator decision, and the layout is not going to change under the feet of a running operating system.
~Andrew
Quoted 3 lines
From: Zhang, Haozhong
Sent: Monday, February 01, 2016 1:44 PM
[...]
Quoted 9 lines
1.2 ACPI Support
ACPI provides two factors of support for NVDIMM. First, NVDIMM devices are described by firmware (BIOS/EFI) to OS via ACPI-defined NVDIMM Firmware Interface Table (NFIT). Second, several functions of NVDIMM, including operations on namespace labels, S.M.A.R.T and hotplug, are provided by ACPI methods (
_DSMand_FIT).
Quoted 4 lines
1.2.1 NFIT
NFIT is a new system description table added in ACPI v6 with signature "NFIT". It contains a set of structures.
Can I consider only NFIT as a minimal requirement, while other stuff (_DSM and _FIT) are optional?
Quoted 6 lines
2. NVDIMM/vNVDIMM Support in Linux Kernel/KVM/QEMU
2.1 NVDIMM Driver in Linux Kernel
[...]
Quoted 7 lines
Userspace applications can mmap(2) the whole pmem into its own virtual address space. Linux kernel maps the system physical address space range occupied by pmem into the virtual address space, so that every normal memory loads/writes with proper flushing instructions are applied to the underlying pmem NVDIMM regions.
Quoted 5 lines
Alternatively, a DAX file system can be made on
/dev/pmemX. Files on that file system can be used in the same way as above. As Linux kernel maps the system address space range occupied by those files on NVDIMM to the virtual address space, reads/writes on those files are applied to the underlying NVDIMM regions as well.
Does it mean only file-based interface is supported by Linux today, and pmem aware application cannot use normal memory allocation interface like malloc for the purpose?
Quoted 15 lines
2.2 vNVDIMM Implementation in KVM/QEMU
(1) Address Mapping
As described before, the host Linux NVDIMM driver provides a block device interface (
/dev/pmem0at the bottom) for a pmem NVDIMM region. QEMU can than mmap(2) that device into its virtual address space (buf). QEMU is responsible to find a proper guest physical address space range that is large enough to hold/dev/pmem0. Then QEMU passes the virtual address of mmapped buf to a KVM APIKVM_SET_USER_MEMORY_REGIONthat maps in EPT the host physical address range of buf to the guest physical address space range where the virtual pmem device will be.
Quoted 5 lines
In this way, all guest writes/reads on the virtual pmem device is applied directly to the host one.
Besides, above implementation also allows to back a virtual pmem device by a mmapped regular file or a piece of ordinary ram.
What's the point of backing pmem with ordinary ram? I can buy-in the value of file-backed option which although slower does sustain the persistency attribute. However with ram-backed method there's no persistency so violates guest expectation.
btw, how is persistency guaranteed in KVM/QEMU, cross guest power off/on? I guess since Qemu process is killed the allocated pmem will be freed so you may switch to file-backed method to keep persistency (however copy would take time for large pmem trunk). Or will you find some way to keep pmem managed separated from qemu qemu life-cycle (then pmem is not efficiently reused)?
Quoted 34 lines
3. Design of vNVDIMM in Xen
3.2 Address Mapping
3.2.2 Alternative Design
Jan Beulich's comments [7] on my question "why must pmem resource management and partition be done in hypervisor":
| Because that's where memory management belongs. And PMEM, | other than PBLK, is just another form of RAM. | ... | The main issue is that this would imo be a layering violationGeorge Dunlap's comments [8]:
| This is not the case for PMEM. The whole point of PMEM (correct me if
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ used as fungible ram| I'm wrong) is to be used for long-term storage that survives over | reboot. It matters very much that a guest be given the same PRAM | after the host is rebooted that it was given before. It doesn't make | any sense to manage it the way Xen currently manages RAM (i.e., that | you request a page and get whatever Xen happens to give you). | | So if Xen is going to use PMEM, it will have to invent an entirely new | interface for guests, and it will have to keep track of those | resources across host reboots. In other words, it will have to | duplicate all the work that Linux already does. What do we gain from | that duplication? Why not just leverage what's already implemented in | dom0? and [9]: | Oh, right -- yes, if the usage model of PRAM is just "cheap slow RAM", | then you're right -- it is just another form of RAM, that should be | treated no differently than say, lowmem: a fungible resource that can be | requested by setting a flag.
Quoted 4 lines
However, pmem is used more as persistent storage than fungible ram, and my design is for the former usage. I would like to leave the detection, driver and partition (either through namespace or file systems) of NVDIMM in Dom0 Linux kernel.
After reading the whole introduction I vote for this option too. One immediate reason why a resource should be managed in Xen, is whether Xen itself also uses it, e.g. normal RAM. In that case Xen has to control the whole resource to protect itself from Dom0 and other user VMs. Given a resource not used by Xen completely, it's reasonable to leave it to Dom0 which reduces code duplication and unnecessary maintenance burden in Xen side, as we have done for whole PCI sub-system and other I/O peripherals. I'm not sure whether there's future value to use pmem in Xen itself, at least for now the primary requirement is about exposing pmem to guest. From that angle reusing NVDIMM driver in Dom0 looks the better choice with less enabling effort to catch up with KVM.
Thanks
Kevin
Hi Kevin,
Thanks for your review!
Quoted 13 lines · Kevin
Quoted 3 lines
From: Zhang, Haozhong
Sent: Monday, February 01, 2016 1:44 PM[...]
Quoted 9 lines
1.2 ACPI Support
ACPI provides two factors of support for NVDIMM. First, NVDIMM devices are described by firmware (BIOS/EFI) to OS via ACPI-defined NVDIMM Firmware Interface Table (NFIT). Second, several functions of NVDIMM, including operations on namespace labels, S.M.A.R.T and hotplug, are provided by ACPI methods (
_DSMand_FIT).
Quoted 8 lines
Quoted 4 lines
1.2.1 NFIT
NFIT is a new system description table added in ACPI v6 with signature "NFIT". It contains a set of structures.
Can I consider only NFIT as a minimal requirement, while other stuff (
_DSMand_FIT) are optional?
No. ACPI namespace devices for NVDIMM should also be present. However, _DSM under those ACPI namespace device can be implemented to support no functions. _FIT is optional and is used for NVDIMM hotplug.
Quoted 20 lines
Quoted 6 lines
2. NVDIMM/vNVDIMM Support in Linux Kernel/KVM/QEMU
2.1 NVDIMM Driver in Linux Kernel
[...]
Quoted 7 lines
Userspace applications can mmap(2) the whole pmem into its own virtual address space. Linux kernel maps the system physical address space range occupied by pmem into the virtual address space, so that every normal memory loads/writes with proper flushing instructions are applied to the underlying pmem NVDIMM regions.
Quoted 5 lines
Alternatively, a DAX file system can be made on
/dev/pmemX. Files on that file system can be used in the same way as above. As Linux kernel maps the system address space range occupied by those files on NVDIMM to the virtual address space, reads/writes on those files are applied to the underlying NVDIMM regions as well.
Quoted 4 lines
Does it mean only file-based interface is supported by Linux today, and pmem aware application cannot use normal memory allocation interface like malloc for the purpose?
right
Quoted 18 lines
Quoted 18 lines
2.2 vNVDIMM Implementation in KVM/QEMU
(1) Address Mapping
As described before, the host Linux NVDIMM driver provides a block device interface (
/dev/pmem0at the bottom) for a pmem NVDIMM region. QEMU can than mmap(2) that device into its virtual address space (buf). QEMU is responsible to find a proper guest physical address space range that is large enough to hold/dev/pmem0. Then QEMU passes the virtual address of mmapped buf to a KVM APIKVM_SET_USER_MEMORY_REGIONthat maps in EPT the host physical address range of buf to the guest physical address space range where the virtual pmem device will be.In this way, all guest writes/reads on the virtual pmem device is applied directly to the host one.
Quoted 8 lines
Quoted 2 lines
Besides, above implementation also allows to back a virtual pmem device by a mmapped regular file or a piece of ordinary ram.
What's the point of backing pmem with ordinary ram? I can buy-in the value of file-backed option which although slower does sustain the persistency attribute. However with ram-backed method there's no persistency so violates guest expectation.
Well, it is not a necessity. The current vNVDIMM implementation in QEMU uses dimm in QEMU that happens to support ram backend. A possible usage is for debugging vNVDIMM on machines without NVDIMM.
Quoted 7 lines
btw, how is persistency guaranteed in KVM/QEMU, cross guest power off/on? I guess since Qemu process is killed the allocated pmem will be freed so you may switch to file-backed method to keep persistency (however copy would take time for large pmem trunk). Or will you find some way to keep pmem managed separated from qemu qemu life-cycle (then pmem is not efficiently reused)?
It all depends on guests themselves. clwb/clflushopt/pcommit instructions are exposed to guest that are used by guests to make writes to pmem persistent.
Haozhong
Quoted 52 lines
Quoted 34 lines
3. Design of vNVDIMM in Xen
3.2 Address Mapping
3.2.2 Alternative Design
Jan Beulich's comments [7] on my question "why must pmem resource management and partition be done in hypervisor":
| Because that's where memory management belongs. And PMEM, | other than PBLK, is just another form of RAM. | ... | The main issue is that this would imo be a layering violationGeorge Dunlap's comments [8]:
| This is not the case for PMEM. The whole point of PMEM (correct me if
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ used as fungible ram| I'm wrong) is to be used for long-term storage that survives over | reboot. It matters very much that a guest be given the same PRAM | after the host is rebooted that it was given before. It doesn't make | any sense to manage it the way Xen currently manages RAM (i.e., that | you request a page and get whatever Xen happens to give you). | | So if Xen is going to use PMEM, it will have to invent an entirely new | interface for guests, and it will have to keep track of those | resources across host reboots. In other words, it will have to | duplicate all the work that Linux already does. What do we gain from | that duplication? Why not just leverage what's already implemented in | dom0? and [9]: | Oh, right -- yes, if the usage model of PRAM is just "cheap slow RAM", | then you're right -- it is just another form of RAM, that should be | treated no differently than say, lowmem: a fungible resource that can be | requested by setting a flag.Quoted 4 lines
However, pmem is used more as persistent storage than fungible ram, and my design is for the former usage. I would like to leave the detection, driver and partition (either through namespace or file systems) of NVDIMM in Dom0 Linux kernel.
After reading the whole introduction I vote for this option too. One immediate reason why a resource should be managed in Xen, is whether Xen itself also uses it, e.g. normal RAM. In that case Xen has to control the whole resource to protect itself from Dom0 and other user VMs. Given a resource not used by Xen completely, it's reasonable to leave it to Dom0 which reduces code duplication and unnecessary maintenance burden in Xen side, as we have done for whole PCI sub-system and other I/O peripherals. I'm not sure whether there's future value to use pmem in Xen itself, at least for now the primary requirement is about exposing pmem to guest. From that angle reusing NVDIMM driver in Dom0 looks the better choice with less enabling effort to catch up with KVM.
Thanks
Kevin
Quoted 11 lines
From: Zhang, Haozhong
Sent: Tuesday, February 02, 2016 3:39 PMQuoted 7 lines
btw, how is persistency guaranteed in KVM/QEMU, cross guest power off/on? I guess since Qemu process is killed the allocated pmem will be freed so you may switch to file-backed method to keep persistency (however copy would take time for large pmem trunk). Or will you find some way to keep pmem managed separated from qemu qemu life-cycle (then pmem is not efficiently reused)?
Quoted 4 lines
It all depends on guests themselves. clwb/clflushopt/pcommit instructions are exposed to guest that are used by guests to make writes to pmem persistent.
I meant from guest p.o.v, a range of pmem should be persistent cross VM power on/off, i.e. the content needs to be maintained somewhere so guest can get it at next power on...
Thanks
Kevin
Quoted 16 lines · Kevin
Quoted 11 lines
From: Zhang, Haozhong
Sent: Tuesday, February 02, 2016 3:39 PMQuoted 7 lines
btw, how is persistency guaranteed in KVM/QEMU, cross guest power off/on? I guess since Qemu process is killed the allocated pmem will be freed so you may switch to file-backed method to keep persistency (however copy would take time for large pmem trunk). Or will you find some way to keep pmem managed separated from qemu qemu life-cycle (then pmem is not efficiently reused)?
Quoted 4 lines
It all depends on guests themselves. clwb/clflushopt/pcommit instructions are exposed to guest that are used by guests to make writes to pmem persistent.
Quoted 6 lines
I meant from guest p.o.v, a range of pmem should be persistent cross VM power on/off, i.e. the content needs to be maintained somewhere so guest can get it at next power on...
Thanks
Kevin
It's just like what we do for guest disk: as long as we always assign the same host pmem device or the same files on file systems on a host pmem device to the guest, the guest can find its last data on pmem.
Haozhong
Quoted 24 lines
From: Zhang, Haozhong
Sent: Tuesday, February 02, 2016 3:53 PMQuoted 20 lines · Kevin
Quoted 11 lines
From: Zhang, Haozhong
Sent: Tuesday, February 02, 2016 3:39 PMQuoted 7 lines
btw, how is persistency guaranteed in KVM/QEMU, cross guest power off/on? I guess since Qemu process is killed the allocated pmem will be freed so you may switch to file-backed method to keep persistency (however copy would take time for large pmem trunk). Or will you find some way to keep pmem managed separated from qemu qemu life-cycle (then pmem is not efficiently reused)?
Quoted 4 lines
It all depends on guests themselves. clwb/clflushopt/pcommit instructions are exposed to guest that are used by guests to make writes to pmem persistent.
I meant from guest p.o.v, a range of pmem should be persistent cross VM power on/off, i.e. the content needs to be maintained somewhere so guest can get it at next power on...
Quoted 8 lines
Quoted 2 lines
Thanks
KevinIt's just like what we do for guest disk: as long as we always assign the same host pmem device or the same files on file systems on a host pmem device to the guest, the guest can find its last data on pmem.
Haozhong
This is the detail which I'd like to learn. If it's Qemu to request host pmem and then free when exit, the very pmem may be allocated to another process later. How do you achieve the 'as long as'?
Thanks
Kevin
Quoted 31 lines · Kevin
Quoted 31 lines
From: Zhang, Haozhong
Sent: Tuesday, February 02, 2016 3:53 PMQuoted 16 lines · Kevin
Quoted 11 lines
From: Zhang, Haozhong
Sent: Tuesday, February 02, 2016 3:39 PMQuoted 7 lines
btw, how is persistency guaranteed in KVM/QEMU, cross guest power off/on? I guess since Qemu process is killed the allocated pmem will be freed so you may switch to file-backed method to keep persistency (however copy would take time for large pmem trunk). Or will you find some way to keep pmem managed separated from qemu qemu life-cycle (then pmem is not efficiently reused)?
Quoted 4 lines
It all depends on guests themselves. clwb/clflushopt/pcommit instructions are exposed to guest that are used by guests to make writes to pmem persistent.
Quoted 6 lines
I meant from guest p.o.v, a range of pmem should be persistent cross VM power on/off, i.e. the content needs to be maintained somewhere so guest can get it at next power on...
Thanks
KevinIt's just like what we do for guest disk: as long as we always assign the same host pmem device or the same files on file systems on a host pmem device to the guest, the guest can find its last data on pmem.
Quoted 7 lines
Quoted 1 line
Haozhong
This is the detail which I'd like to learn. If it's Qemu to request host pmem and then free when exit, the very pmem may be allocated to another process later. How do you achieve the 'as long as'?
QEMU receives following parameters
-object memory-backend-file,id=mem1,share,mem-path=/dev/pmem0,size=10G \
-device nvdimm,memdev=mem1,id=nv1that configs a vNVDIMM device backed by the host pmem device /dev/pmem0. It can also be replaced by files on the file system on /dev/pmem0. The system address space range occupied by /dev/pmem0 or files on /dev/pmem0 are then mapped into the guest physical address space, and all accesses from guest are then directly applied on the host device without any interception of QEMU.
If we always provide the same vNVDIMM parameters (specially mem-path and size), the guest can observe the same vNVDIMM devices across boot.
In Xen, I'll implement the similar configuration options in xl.cfg, e.g.
nvdimms = [ '/dev/pmem0', '/dev/pmem1', '/mnt/pmem2/file_on_pmem2' ]
Haozhong
Quoted 17 lines
Quoted 17 lines
2.2 vNVDIMM Implementation in KVM/QEMU
(1) Address Mapping
As described before, the host Linux NVDIMM driver provides a block device interface (
/dev/pmem0at the bottom) for a pmem NVDIMM region. QEMU can than mmap(2) that device into its virtual address space (buf). QEMU is responsible to find a proper guest physical address space range that is large enough to hold/dev/pmem0. Then QEMU passes the virtual address of mmapped buf to a KVM APIKVM_SET_USER_MEMORY_REGIONthat maps in EPT the host physical address range of buf to the guest physical address space range where the virtual pmem device will be.In this way, all guest writes/reads on the virtual pmem device is applied directly to the host one.
Quoted 7 lines
Quoted 2 lines
Besides, above implementation also allows to back a virtual pmem device by a mmapped regular file or a piece of ordinary ram.
What's the point of backing pmem with ordinary ram? I can buy-in the value of file-backed option which although slower does sustain the persistency attribute. However with ram-backed method there's no persistency so violates guest expectation.
Containers - like the Intel Clear Containers? You can use this work to stitch an exploded initramfs on a tmpfs right in the guest. And you could do that for multiple guests.
Granted this has nothing to do with pmem, but this work would allow one to setup containers this way.
Haozhong, thanks for your work!
Quoted 50 lines · Haozhong Zhang
3.2 Address Mapping
3.2.1 My Design
The overview of this design is shown in the following figure.
Dom0 | DomU | | QEMU | +...+--------------------+...+-----+ | VA | | Label Storage Area | | buf | | +...+--------------------+...+-----+ | ^ ^ ^ | | | | | V | | | +-------+ +-------+ mmap(2) | | vACPI | | v_DSM | | | | +----+------------+ +-------+ +-------+ | | | SPA | | /dev/pmem0 | ^ ^ +------+ | | +----+------------+ --------|-----------|-----|------------|-- | ^ ^ | | | | | | | | +------+ +------------~-----~-------------+ | | | | | | XEN_DOMCTL_memory_mapping | | | +-----~--------------------------+ | | | | | | | +----+------------+ | Linux | | SPA | | /dev/pmem0 | | +------+ +------+ | | +----+------------+ | | ACPI | | _DSM | | | ^ | +------+ +------+ | | | | | | | | Dom0 Driver | hvmloader/xl | --------|----|-------------------|---------------------|----------|--------------- | +-------------------~---------------------~----------+ Xen | | | +------------------------~---------------------+ ---------------------------------|------------------------------------------------ +----------------+ | +-------------+ HW | NVDIMM | +-------------+This design treats host NVDIMM devices as ordinary MMIO devices:
(1) Dom0 Linux NVDIMM driver is responsible to detect (through NFIT) and drive host NVDIMM devices (implementing block device interface). Namespaces and file systems on host NVDIMM devices are handled by Dom0 Linux as well.
Quoted 6 lines
(2) QEMU mmap(2) the pmem NVDIMM devices (
/dev/pmem0) into its virtual address space (buf).(3) QEMU gets the host physical address of buf, i.e. the host system physical address that is occupied by
/dev/pmem0, and calls Xen hypercallXEN_DOMCTL_memory_mappingto map it to a DomU.
How is this going to work from a security perspective? Is it going to require running QEMU as root in Dom0, which will prevent NVDIMM from working by default on Xen? If so, what's the plan?
Quoted 11 lines
(ACPI part is described in Section 3.3 later)
Above (1)(2) have already been done in current QEMU. Only (3) is needed to implement in QEMU. No change is needed in Xen for address mapping in this design.
Open: It seems no system call/ioctl is provided by Linux kernel to
get the physical address from a virtual address. /proc/<qemu_pid>/pagemap provides information of mapping from VA to PA. Is it an acceptable solution to let QEMU parse this file to get the physical address?
Does it work in a non-root scenario?
Quoted 6 lines
Open: For a large pmem, mmap(2) is very possible to not map all SPA
occupied by pmem at the beginning, i.e. QEMU may not be able to get all SPA of pmem from buf (in virtual address space) when callingXEN_DOMCTL_memory_mapping.
Can mmap flagMAP_LOCKEDor mlock(2) be used to enforce the entire pmem being mmaped?
Ditto
Quoted 35 lines
3.2.2 Alternative Design
Jan Beulich's comments [7] on my question "why must pmem resource management and partition be done in hypervisor":
| Because that's where memory management belongs. And PMEM, | other than PBLK, is just another form of RAM. | ... | The main issue is that this would imo be a layering violationGeorge Dunlap's comments [8]:
| This is not the case for PMEM. The whole point of PMEM (correct me if
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ used as fungible ram| I'm wrong) is to be used for long-term storage that survives over | reboot. It matters very much that a guest be given the same PRAM | after the host is rebooted that it was given before. It doesn't make | any sense to manage it the way Xen currently manages RAM (i.e., that | you request a page and get whatever Xen happens to give you). | | So if Xen is going to use PMEM, it will have to invent an entirely new | interface for guests, and it will have to keep track of those | resources across host reboots. In other words, it will have to | duplicate all the work that Linux already does. What do we gain from | that duplication? Why not just leverage what's already implemented in | dom0? and [9]: | Oh, right -- yes, if the usage model of PRAM is just "cheap slow RAM", | then you're right -- it is just another form of RAM, that should be | treated no differently than say, lowmem: a fungible resource that can be | requested by setting a flag.However, pmem is used more as persistent storage than fungible ram, and my design is for the former usage. I would like to leave the detection, driver and partition (either through namespace or file systems) of NVDIMM in Dom0 Linux kernel.
Quoted 5 lines
I notice that current
XEN_DOMCTL_memory_mappingdoes not make santiy check for the physical address and size passed from caller (QEMU). Can QEMU be always trusted? If not, we would need to make Xen aware of the SPA range of pmem so that it can refuse map physical address in neither the normal ram nor pmem.
Indeed
Quoted 68 lines
Instead of duplicating the detection code (parsing NFIT and evaluating
_FIT) in Dom0 Linux kernel, we decide to patch Dom0 Linux kernel to pass parameters of host pmem NVDIMM devices to Xen hypervisor:
(1) Add a global
struct rangesetpmem_rangeset
in Xen hypervisor to record all SPA ranges of detected pmem devices. Each range inpmem_rangesetcorresponds to a pmem device.(2) Add a hypercall
XEN_SYSCTL_add_pmem_range
(should it be a sysctl or a platform op?)
that receives a pair of parameters (addr: starting SPA of pmem region, len: size of pmem region) and add a range (addr, addr + len - 1) innvdimm_rangset.(3) Add a hypercall
XEN_DOMCTL_pmem_mapping
that takes the same parameters asXEN_DOMCTL_memory_mappingand maps a given host pmem range to guest. It checks whether the given host pmem range is in thepmem_rangesetbefore making the actual mapping.(4) Patch Linux NVDIMM driver to call
XEN_SYSCTL_add_pmem_rangewhenever it detects a pmem device.(5) Patch QEMU to use
XEN_DOMCTL_pmem_mappingfor mapping host pmem devices.3.3 Guest ACPI Emulation
3.3.1 My Design
Guest ACPI emulation is composed of two parts: building guest NFIT and SSDT that defines ACPI namespace devices for NVDIMM, and emulating guest
_DSM.(1) Building Guest ACPI Tables
This design reuses and extends hvmloader's existing mechanism that loads passthrough ACPI tables from binary files to load NFIT and SSDT tables built by QEMU:
1) Because the current QEMU does not building any ACPI tables when it runs as the Xen device model, this design needs to patch QEMU to build NFIT and SSDT (so far only NFIT and SSDT) in this case.2) QEMU copies NFIT and SSDT to the end of guest memory below 4G. The guest address and size of those tables are written into xenstore (/local/domain/domid/hvmloader/dm-acpi/{address,length}).
3) hvmloader is patched to probe and load device model passthrough ACPI tables from above xenstore keys. The detected ACPI tables are then appended to the end of existing guest ACPI tables just like what current
construct_passthrough_tables()does.Reasons for this design are listed below:
- NFIT and SSDT in question are quite self-contained, i.e. they do not refer to other ACPI tables and not conflict with existing guest ACPI tables in Xen. Therefore, it is safe to copy them from QEMU and append to existing guest ACPI tables.- A primary portion of current and future vNVDIMM implementation is about building ACPI tables. And this design also leave the emulation of
_DSMto QEMU which needs to keep consistency with NFIT and SSDT itself builds. Therefore, reusing NFIT and SSDT from QEMU can ease the maintenance.
Quoted 3 lines
- Anthony's work to pass ACPI tables from the toolstack to hvmloader does not move building SSDT (and NFIT) to toolstack, so this design can still put them in hvmloader.
If we start asking QEMU to build ACPI tables, why should we stop at NFIT and SSDT? Once upon a time somebody made the decision that ACPI tables on Xen should be static and included in hvmloader. That might have been a bad decision but at least it was coherent. Loading only *some* tables from QEMU, but not others, it feels like an incomplete design to me.
For example, QEMU is currently in charge of emulating the PCI bus, why shouldn't it be QEMU that generates the PRT and MCFG?
Quoted 18 lines
(2) Emulating Guest
_DSMBecause the same NFIT and SSDT are used, we can leave the emulation of guest
_DSMto QEMU. Just as what it does with KVM, QEMU registers the_DSMbuffer as MMIO region with Xen and then all guest evaluations of_DSMare trapped and emulated by QEMU.3.3.2 Alternative Design 1: switching to QEMU
Stefano Stabellini's comments [10]:
| I don't think it is wise to have two components which both think are | in control of generating ACPI tables, hvmloader (soon to be the | toolstack with Anthony's work) and QEMU. From an architectural | perspective, it doesn't look robust to me. | | Could we take this opportunity to switch to QEMU generating the whole | set of ACPI tables?
Quoted 4 lines
So an alternative design could be switching to QEMU to generate the whole set of guest ACPI tables. In this way, no controversy would happen between multiple agents QEMU and hvmloader. (is this what Stefano Stabellini mean by 'robust'?)
Right
Quoted 27 lines
However, looking at the code building ACPI tables in QEMU and hvmloader, they are quite different. As ACPI tables are important for OS to boot and operate device, it's critical to ensure ACPI tables built by QEMU would not break existing guests on Xen. Though I believe it could be done after a thorough investigation and adjustment, it may take quite a lot of work and tests and should be another project besides enabling vNVDIMM in Xen.
3.3.3 Alternative Design 2: keeping in Xen
Alternative to switching to QEMU, another design would be building NFIT and SSDT in hvmloader or toolstack.
The amount and parameters of sub-structures in guest NFIT vary according to different vNVDIMM configurations that can not be decided at compile-time. In contrast, current hvmloader and toolstack can only build static ACPI tables, i.e. their contents are decided statically at compile-time and independent from the guest configuration. In order to build guest NFIT at runtime, this design may take following steps:
(1) xl converts NVDIMM configurations in xl.cfg to corresponding QEMU options,(2) QEMU accepts above options, figures out the start SPA range address/size/NVDIMM device handles/..., and writes them in xenstore. No ACPI table is built by QEMU.
Quoted 8 lines
(3) Either xl or hvmloader reads above parameters from xenstore and builds the NFIT table.
For guest SSDT, it would take more work. The ACPI namespace devices are defined in SSDT by AML, so an AML builder would be needed to generate those definitions at runtime.
This alternative design still needs more work than the first design.
I prefer switching to QEMU building all ACPI tables for devices that it is emulating. However this alternative is good too because it is coherent with the current design.
Quoted 18 lines
References:
[1] ACPI Specification v6,
http://www.uefi.org/sites/default/files/resources/ACPI_6.0.pdf
[2] NVDIMM Namespace Specification,
http://pmem.io/documents/NVDIMM_Namespace_Spec.pdf
[3] NVDIMM Block Window Driver Writer's Guide,
http://pmem.io/documents/NVDIMM_Driver_Writers_Guide.pdf
[4] NVDIMM DSM Interface Example,
http://pmem.io/documents/NVDIMM_DSM_Interface_Example.pdf
[5] UEFI Specification v2.6,http://www.uefi.org/sites/default/files/resources/UEFI%20Spec%202_6.pdf [6] Intel Architecture Instruction Set Extensions Programming Reference, https://software.intel.com/sites/default/files/managed/07/b7/319433-023.pdf[7] http://www.gossamer-threads.com/lists/xen/devel/414945#414945
[8] http://www.gossamer-threads.com/lists/xen/devel/415658#415658
[9] http://www.gossamer-threads.com/lists/xen/devel/415681#415681
[10] http://lists.xenproject.org/archives/html/xen-devel/2016-01/msg00271.html
Quoted 56 lines · Stefano Stabellini
Haozhong, thanks for your work!
Quoted 53 lines · Haozhong Zhang
3.2 Address Mapping
3.2.1 My Design
The overview of this design is shown in the following figure.
Dom0 | DomU | | QEMU | +...+--------------------+...+-----+ | VA | | Label Storage Area | | buf | | +...+--------------------+...+-----+ | ^ ^ ^ | | | | | V | | | +-------+ +-------+ mmap(2) | | vACPI | | v_DSM | | | | +----+------------+ +-------+ +-------+ | | | SPA | | /dev/pmem0 | ^ ^ +------+ | | +----+------------+ --------|-----------|-----|------------|-- | ^ ^ | | | | | | | | +------+ +------------~-----~-------------+ | | | | | | XEN_DOMCTL_memory_mapping | | | +-----~--------------------------+ | | | | | | | +----+------------+ | Linux | | SPA | | /dev/pmem0 | | +------+ +------+ | | +----+------------+ | | ACPI | | _DSM | | | ^ | +------+ +------+ | | | | | | | | Dom0 Driver | hvmloader/xl | --------|----|-------------------|---------------------|----------|--------------- | +-------------------~---------------------~----------+ Xen | | | +------------------------~---------------------+ ---------------------------------|------------------------------------------------ +----------------+ | +-------------+ HW | NVDIMM | +-------------+This design treats host NVDIMM devices as ordinary MMIO devices:
(1) Dom0 Linux NVDIMM driver is responsible to detect (through NFIT) and drive host NVDIMM devices (implementing block device interface). Namespaces and file systems on host NVDIMM devices are handled by Dom0 Linux as well.(2) QEMU mmap(2) the pmem NVDIMM devices (
/dev/pmem0) into its virtual address space (buf).
Quoted 8 lines
Quoted 3 lines
(3) QEMU gets the host physical address of buf, i.e. the host system physical address that is occupied by
/dev/pmem0, and calls Xen hypercallXEN_DOMCTL_memory_mappingto map it to a DomU.How is this going to work from a security perspective? Is it going to require running QEMU as root in Dom0, which will prevent NVDIMM from working by default on Xen? If so, what's the plan?
Oh, I forgot to address the non-root qemu issues in this design ...
The default user:group of /dev/pmem0 is root:disk, and its permission is rw-rw----. We could lift the others permission to rw, so that non-root QEMU can mmap /dev/pmem0. But it looks too risky.
Or, we can make a file system on /dev/pmem0, create files on it, set the owner of those files to xen-qemuuser-domid$domid, and then pass those files to QEMU. In this way, non-root QEMU should be able to mmap those files.
Quoted 8 lines
Quoted 8 lines
(ACPI part is described in Section 3.3 later)
Above (1)(2) have already been done in current QEMU. Only (3) is needed to implement in QEMU. No change is needed in Xen for address mapping in this design.
Quoted 8 lines
Quoted 5 lines
Open: It seems no system call/ioctl is provided by Linux kernel to
get the physical address from a virtual address. /proc/<qemu_pid>/pagemap provides information of mapping from VA to PA. Is it an acceptable solution to let QEMU parse this file to get the physical address?Does it work in a non-root scenario?
Seemingly no, according to Documentation/vm/pagemap.txt in Linux kernel:
| Since Linux 4.0 only users with the CAP_SYS_ADMIN capability can get PFNs. | In 4.0 and 4.1 opens by unprivileged fail with -EPERM. Starting from | 4.2 the PFN field is zeroed if the user does not have CAP_SYS_ADMIN. | Reason: information about PFNs helps in exploiting Rowhammer vulnerability.
A possible alternative is to add a new hypercall similar to XEN_DOMCTL_memory_mapping but receiving virtual address as the address parameter and translating to machine address in the hypervisor.
Quoted 10 lines
Quoted 7 lines
Open: For a large pmem, mmap(2) is very possible to not map all SPA
occupied by pmem at the beginning, i.e. QEMU may not be able to get all SPA of pmem from buf (in virtual address space) when callingXEN_DOMCTL_memory_mapping.
Can mmap flagMAP_LOCKEDor mlock(2) be used to enforce the entire pmem being mmaped?Ditto
No. If I take the above alternative for the first open, maybe the new hypercall above can inject page faults into dom0 for the unmapped virtual address so as to enforce dom0 Linux to create the page mapping.
Quoted 45 lines
Quoted 36 lines
3.2.2 Alternative Design
Jan Beulich's comments [7] on my question "why must pmem resource management and partition be done in hypervisor":
| Because that's where memory management belongs. And PMEM, | other than PBLK, is just another form of RAM. | ... | The main issue is that this would imo be a layering violationGeorge Dunlap's comments [8]:
| This is not the case for PMEM. The whole point of PMEM (correct me if
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ used as fungible ram| I'm wrong) is to be used for long-term storage that survives over | reboot. It matters very much that a guest be given the same PRAM | after the host is rebooted that it was given before. It doesn't make | any sense to manage it the way Xen currently manages RAM (i.e., that | you request a page and get whatever Xen happens to give you). | | So if Xen is going to use PMEM, it will have to invent an entirely new | interface for guests, and it will have to keep track of those | resources across host reboots. In other words, it will have to | duplicate all the work that Linux already does. What do we gain from | that duplication? Why not just leverage what's already implemented in | dom0? and [9]: | Oh, right -- yes, if the usage model of PRAM is just "cheap slow RAM", | then you're right -- it is just another form of RAM, that should be | treated no differently than say, lowmem: a fungible resource that can be | requested by setting a flag.However, pmem is used more as persistent storage than fungible ram, and my design is for the former usage. I would like to leave the detection, driver and partition (either through namespace or file systems) of NVDIMM in Dom0 Linux kernel.
Quoted 5 lines
I notice that current
XEN_DOMCTL_memory_mappingdoes not make santiy check for the physical address and size passed from caller (QEMU). Can QEMU be always trusted? If not, we would need to make Xen aware of the SPA range of pmem so that it can refuse map physical address in neither the normal ram nor pmem.Indeed
[...]
Quoted 40 lines
Quoted 40 lines
3.3 Guest ACPI Emulation
3.3.1 My Design
Guest ACPI emulation is composed of two parts: building guest NFIT and SSDT that defines ACPI namespace devices for NVDIMM, and emulating guest
_DSM.(1) Building Guest ACPI Tables
This design reuses and extends hvmloader's existing mechanism that loads passthrough ACPI tables from binary files to load NFIT and SSDT tables built by QEMU:
1) Because the current QEMU does not building any ACPI tables when it runs as the Xen device model, this design needs to patch QEMU to build NFIT and SSDT (so far only NFIT and SSDT) in this case.2) QEMU copies NFIT and SSDT to the end of guest memory below 4G. The guest address and size of those tables are written into xenstore (/local/domain/domid/hvmloader/dm-acpi/{address,length}).
3) hvmloader is patched to probe and load device model passthrough ACPI tables from above xenstore keys. The detected ACPI tables are then appended to the end of existing guest ACPI tables just like what current
construct_passthrough_tables()does.Reasons for this design are listed below:
- NFIT and SSDT in question are quite self-contained, i.e. they do not refer to other ACPI tables and not conflict with existing guest ACPI tables in Xen. Therefore, it is safe to copy them from QEMU and append to existing guest ACPI tables.- A primary portion of current and future vNVDIMM implementation is about building ACPI tables. And this design also leave the emulation of
_DSMto QEMU which needs to keep consistency with NFIT and SSDT itself builds. Therefore, reusing NFIT and SSDT from QEMU can ease the maintenance.
Quoted 6 lines
Quoted 3 lines
- Anthony's work to pass ACPI tables from the toolstack to hvmloader does not move building SSDT (and NFIT) to toolstack, so this design can still put them in hvmloader.
If we start asking QEMU to build ACPI tables, why should we stop at NFIT and SSDT?
for easing my development of supporting vNVDIMM in Xen ... I mean NFIT and SSDT are the only two tables needed for this purpose and I'm afraid to break exiting guests if I completely switch to QEMU for guest ACPI tables.
Quoted 8 lines
Once upon a time somebody made the decision that ACPI tables on Xen should be static and included in hvmloader. That might have been a bad decision but at least it was coherent. Loading only *some* tables from QEMU, but not others, it feels like an incomplete design to me.
For example, QEMU is currently in charge of emulating the PCI bus, why shouldn't it be QEMU that generates the PRT and MCFG?
To Keir, Jan and Andrew:
Are there anything related to ACPI that must be done (or are better to be done) in hvmloader?
Quoted 19 lines
Quoted 19 lines
(2) Emulating Guest
_DSMBecause the same NFIT and SSDT are used, we can leave the emulation of guest
_DSMto QEMU. Just as what it does with KVM, QEMU registers the_DSMbuffer as MMIO region with Xen and then all guest evaluations of_DSMare trapped and emulated by QEMU.3.3.2 Alternative Design 1: switching to QEMU
Stefano Stabellini's comments [10]:
| I don't think it is wise to have two components which both think are | in control of generating ACPI tables, hvmloader (soon to be the | toolstack with Anthony's work) and QEMU. From an architectural | perspective, it doesn't look robust to me. | | Could we take this opportunity to switch to QEMU generating the whole | set of ACPI tables?
Quoted 7 lines
Quoted 4 lines
So an alternative design could be switching to QEMU to generate the whole set of guest ACPI tables. In this way, no controversy would happen between multiple agents QEMU and hvmloader. (is this what Stefano Stabellini mean by 'robust'?)
Right
I understand that switching to QEMU for all guest ACPI tables would probably ease the maintenance for guest ACPI tables. However, in general, is it true that we currently need to fix regressions introduced by qemu-xen whenever we upgrade it to the upstream? If yes, is it reasonable to turn to QEMU for only NVDIMM ACPI tables and fix regressions/controversy whenever upgraded qemu-xen changes NVDIMM ACPI tables?
Quoted 35 lines
Quoted 35 lines
However, looking at the code building ACPI tables in QEMU and hvmloader, they are quite different. As ACPI tables are important for OS to boot and operate device, it's critical to ensure ACPI tables built by QEMU would not break existing guests on Xen. Though I believe it could be done after a thorough investigation and adjustment, it may take quite a lot of work and tests and should be another project besides enabling vNVDIMM in Xen.
3.3.3 Alternative Design 2: keeping in Xen
Alternative to switching to QEMU, another design would be building NFIT and SSDT in hvmloader or toolstack.
The amount and parameters of sub-structures in guest NFIT vary according to different vNVDIMM configurations that can not be decided at compile-time. In contrast, current hvmloader and toolstack can only build static ACPI tables, i.e. their contents are decided statically at compile-time and independent from the guest configuration. In order to build guest NFIT at runtime, this design may take following steps:
(1) xl converts NVDIMM configurations in xl.cfg to corresponding QEMU options,(2) QEMU accepts above options, figures out the start SPA range address/size/NVDIMM device handles/..., and writes them in xenstore. No ACPI table is built by QEMU.
(3) Either xl or hvmloader reads above parameters from xenstore and builds the NFIT table.
For guest SSDT, it would take more work. The ACPI namespace devices are defined in SSDT by AML, so an AML builder would be needed to generate those definitions at runtime.
Quoted 6 lines
Quoted 1 line
This alternative design still needs more work than the first design.
I prefer switching to QEMU building all ACPI tables for devices that it is emulating. However this alternative is good too because it is coherent with the current design.
I would prefer to this one if the final conclusion is that only one agent should be allowed to build guest ACPI. As I said above, it looks like a big change to switch to QEMU for all ACPI tables and I'm afraid it would break some existing guests.
Thanks,
Haozhong
Quoted 19 lines
Quoted 19 lines
References:
[1] ACPI Specification v6,
http://www.uefi.org/sites/default/files/resources/ACPI_6.0.pdf
[2] NVDIMM Namespace Specification,
http://pmem.io/documents/NVDIMM_Namespace_Spec.pdf
[3] NVDIMM Block Window Driver Writer's Guide,
http://pmem.io/documents/NVDIMM_Driver_Writers_Guide.pdf
[4] NVDIMM DSM Interface Example,
http://pmem.io/documents/NVDIMM_DSM_Interface_Example.pdf
[5] UEFI Specification v2.6,http://www.uefi.org/sites/default/files/resources/UEFI%20Spec%202_6.pdf [6] Intel Architecture Instruction Set Extensions Programming Reference, https://software.intel.com/sites/default/files/managed/07/b7/319433-023.pdf[7] http://www.gossamer-threads.com/lists/xen/devel/414945#414945
[8] http://www.gossamer-threads.com/lists/xen/devel/415658#415658
[9] http://www.gossamer-threads.com/lists/xen/devel/415681#415681
[10] http://lists.xenproject.org/archives/html/xen-devel/2016-01/msg00271.html
Quoted 7 lines
Quoted 1 line
Quoted 1 line · On 03.02.16 at 08:00, <[email protected]> wrote:
Quoted 5 lines · Stefano Stabellini
Once upon a time somebody made the decision that ACPI tables on Xen should be static and included in hvmloader. That might have been a bad decision but at least it was coherent. Loading only *some* tables from QEMU, but not others, it feels like an incomplete design to me.
Quoted 8 lines
Quoted 3 lines
For example, QEMU is currently in charge of emulating the PCI bus, why shouldn't it be QEMU that generates the PRT and MCFG?
To Keir, Jan and Andrew:
Are there anything related to ACPI that must be done (or are better to be done) in hvmloader?
Some of the static tables (FADT and HPET come to mind) likely would better continue to live in hvmloader. MCFG (for example) coming from qemu, otoh, would be quite natural (and would finally allow MMCFG support for guests in the first place). I.e. ...
Quoted 8 lines
Quoted 3 lines
I prefer switching to QEMU building all ACPI tables for devices that it is emulating. However this alternative is good too because it is coherent with the current design.
I would prefer to this one if the final conclusion is that only one agent should be allowed to build guest ACPI. As I said above, it looks like a big change to switch to QEMU for all ACPI tables and I'm afraid it would break some existing guests.
... I indeed think that tables should come from qemu for components living in qemu, and from hvmloader for components coming from Xen.
Jan
Quoted 22 lines · Jan Beulich
Quoted 7 lines
Quoted 1 line
Quoted 1 line · On 03.02.16 at 08:00, <[email protected]> wrote:
Quoted 5 lines · Stefano Stabellini
Once upon a time somebody made the decision that ACPI tables on Xen should be static and included in hvmloader. That might have been a bad decision but at least it was coherent. Loading only *some* tables from QEMU, but not others, it feels like an incomplete design to me.
Quoted 7 lines
Quoted 3 lines
For example, QEMU is currently in charge of emulating the PCI bus, why shouldn't it be QEMU that generates the PRT and MCFG?
To Keir, Jan and Andrew:
Are there anything related to ACPI that must be done (or are better to be done) in hvmloader?
Some of the static tables (FADT and HPET come to mind) likely would better continue to live in hvmloader. MCFG (for example) coming from qemu, otoh, would be quite natural (and would finally allow MMCFG support for guests in the first place). I.e. ...
Quoted 3 lines
Quoted 3 lines
I prefer switching to QEMU building all ACPI tables for devices that it is emulating. However this alternative is good too because it is coherent with the current design.
Quoted 6 lines
Quoted 4 lines
I would prefer to this one if the final conclusion is that only one agent should be allowed to build guest ACPI. As I said above, it looks like a big change to switch to QEMU for all ACPI tables and I'm afraid it would break some existing guests.
... I indeed think that tables should come from qemu for components living in qemu, and from hvmloader for components coming from Xen.
I agree.
There has to be a single entity responsible for collating the eventual ACPI handed to the guest, and this is definitely HVMLoader.
However, it is correct that Qemu create the ACPI tables for the devices it emulates for the guest.
We need to agree on a mechanism whereby each entity can provide their own subset of the ACPI tables to HVMLoader, and have HVMLoader present the final set properly to the VM.
There is an existing usecase of passing the Host SLIC table to a VM, for OEM Versions of Windows. I believe this is achieved with HVM_XS_ACPI_PT_{ADDRESS,LENGTH}, but that mechanism is a little inflexible and could probably do with being made a little more generic.
~Andrew
Quoted 38 lines · Andrew Cooper
Quoted 22 lines · Jan Beulich
Quoted 7 lines
Quoted 1 line
Quoted 1 line · On 03.02.16 at 08:00, <[email protected]> wrote:
Quoted 5 lines · Stefano Stabellini
Once upon a time somebody made the decision that ACPI tables on Xen should be static and included in hvmloader. That might have been a bad decision but at least it was coherent. Loading only *some* tables from QEMU, but not others, it feels like an incomplete design to me.
Quoted 7 lines
Quoted 3 lines
For example, QEMU is currently in charge of emulating the PCI bus, why shouldn't it be QEMU that generates the PRT and MCFG?
To Keir, Jan and Andrew:
Are there anything related to ACPI that must be done (or are better to be done) in hvmloader?
Some of the static tables (FADT and HPET come to mind) likely would better continue to live in hvmloader. MCFG (for example) coming from qemu, otoh, would be quite natural (and would finally allow MMCFG support for guests in the first place). I.e. ...
Quoted 3 lines
Quoted 3 lines
I prefer switching to QEMU building all ACPI tables for devices that it is emulating. However this alternative is good too because it is coherent with the current design.
Quoted 6 lines
Quoted 4 lines
I would prefer to this one if the final conclusion is that only one agent should be allowed to build guest ACPI. As I said above, it looks like a big change to switch to QEMU for all ACPI tables and I'm afraid it would break some existing guests.
... I indeed think that tables should come from qemu for components living in qemu, and from hvmloader for components coming from Xen.
I agree.
There has to be a single entity responsible for collating the eventual ACPI handed to the guest, and this is definitely HVMLoader.
However, it is correct that Qemu create the ACPI tables for the devices it emulates for the guest.
Quoted 9 lines
We need to agree on a mechanism whereby each entity can provide their own subset of the ACPI tables to HVMLoader, and have HVMLoader present the final set properly to the VM.
There is an existing usecase of passing the Host SLIC table to a VM, for OEM Versions of Windows. I believe this is achieved with HVM_XS_ACPI_PT_{ADDRESS,LENGTH}, but that mechanism is a little inflexible and could probably do with being made a little more generic.
Yes, that is what one of my v1 patches does
([PATCH 4/4] hvmloader: add support to load extra ACPI tables from qemu).
It extends the existing construct_passthrough_tables() to get the address and size of acpi tables from its parameters (a pair of xenstore keys) rather than the hardcoded ones.
Quoted 38 lines · Andrew Cooper
Quoted 22 lines · Jan Beulich
Quoted 7 lines
Quoted 1 line
Quoted 1 line · On 03.02.16 at 08:00, <[email protected]> wrote:
Quoted 5 lines · Stefano Stabellini
Once upon a time somebody made the decision that ACPI tables on Xen should be static and included in hvmloader. That might have been a bad decision but at least it was coherent. Loading only *some* tables from QEMU, but not others, it feels like an incomplete design to me.
Quoted 7 lines
Quoted 3 lines
For example, QEMU is currently in charge of emulating the PCI bus, why shouldn't it be QEMU that generates the PRT and MCFG?
To Keir, Jan and Andrew:
Are there anything related to ACPI that must be done (or are better to be done) in hvmloader?
Some of the static tables (FADT and HPET come to mind) likely would better continue to live in hvmloader. MCFG (for example) coming from qemu, otoh, would be quite natural (and would finally allow MMCFG support for guests in the first place). I.e. ...
Quoted 3 lines
Quoted 3 lines
I prefer switching to QEMU building all ACPI tables for devices that it is emulating. However this alternative is good too because it is coherent with the current design.
Quoted 6 lines
Quoted 4 lines
I would prefer to this one if the final conclusion is that only one agent should be allowed to build guest ACPI. As I said above, it looks like a big change to switch to QEMU for all ACPI tables and I'm afraid it would break some existing guests.
... I indeed think that tables should come from qemu for components living in qemu, and from hvmloader for components coming from Xen.
I agree.
There has to be a single entity responsible for collating the eventual ACPI handed to the guest, and this is definitely HVMLoader.
However, it is correct that Qemu create the ACPI tables for the devices it emulates for the guest.
Quoted 8 lines
We need to agree on a mechanism whereby each entity can provide their own subset of the ACPI tables to HVMLoader, and have HVMLoader present the final set properly to the VM.
There is an existing usecase of passing the Host SLIC table to a VM, for OEM Versions of Windows. I believe this is achieved with HVM_XS_ACPI_PT_{ADDRESS,LENGTH}, but that mechanism is a little inflexible and could probably do with being made a little more generic.
A while back I added a generic mechanism to load extra ACPI tables into a guest, configurable at runtime. It looks like the functionality is still present. That might be an option.
Also, following the thread, it wasn't clear if some of the tables like the SSDT for the NVDIMM device and it's _FIT/_DSM methods were something that could be statically created at build time. If it is something that needs to be generated at runtime (e.g. platform specific), I have a library that can generate any AML on the fly and create SSDTs.
Anyway just FYI in case this is helpful.
Quoted 8 lines
~Andrew
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Signature · 1 line
Ross Philipson
Quoted 1 line · Ross Philipson
On 02/03/2016 09:09 AM, Andrew Cooper wrote:
[...]
Quoted 21 lines
Quoted 8 lines
I agree.
There has to be a single entity responsible for collating the eventual ACPI handed to the guest, and this is definitely HVMLoader.
However, it is correct that Qemu create the ACPI tables for the devices it emulates for the guest.
Quoted 8 lines
We need to agree on a mechanism whereby each entity can provide their own subset of the ACPI tables to HVMLoader, and have HVMLoader present the final set properly to the VM.
There is an existing usecase of passing the Host SLIC table to a VM, for OEM Versions of Windows. I believe this is achieved with HVM_XS_ACPI_PT_{ADDRESS,LENGTH}, but that mechanism is a little inflexible and could probably do with being made a little more generic.
A while back I added a generic mechanism to load extra ACPI tables into a guest, configurable at runtime. It looks like the functionality is still present. That might be an option.
Quoted 8 lines
Also, following the thread, it wasn't clear if some of the tables like the SSDT for the NVDIMM device and it's _FIT/_DSM methods were something that could be statically created at build time. If it is something that needs to be generated at runtime (e.g. platform specific), I have a library that can generate any AML on the fly and create SSDTs.
Anyway just FYI in case this is helpful.
Hi Ross,
Thanks for the information!
SSDT for NVDIMM devices can not be created statically, because the number of some items in it can not be determined at build time. For example, the number of NVDIMM ACPI namespace devices (_DSM is under it) defined in SSDT is determined by the number of vNVDIMM devices in domain configuration. FYI, a sample SSDT for NVDIMM looks like
Scope (\_SB){
Device (NVDR) // NVDIMM Root device
{
Name (_HID, “ACPI0012”)
Method (_STA) {...}
Method (_FIT) {...}
Method (_DSM, ...) {
...
}
} Device (NVD0) // 1st NVDIMM Device
{
Name(_ADR, h0)
Method (_DSM, ...) {
...
}
}
Device (NVD1) // 2nd NVDIMM Device
{
Name(_ADR, h1)
Method (_DSM, ...) {
...
}
}
...}
I had ported QEMU's AML builder code as well as NVDIMM ACPI building code to hvmloader and it did work, but then there was too much duplicated code for vNVDIMM between QEMU and hvmloader for vNVDIMM. Therefore, I prefer to let QEMU that emulates vNVDIMM devices to build those tables, as in Andrew and Jan's replies.
Thanks,
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 71 lines · Haozhong Zhang
Quoted 1 line · Ross Philipson
On 02/03/2016 09:09 AM, Andrew Cooper wrote:
[...]
Quoted 21 lines
Quoted 8 lines
I agree.
There has to be a single entity responsible for collating the eventual ACPI handed to the guest, and this is definitely HVMLoader.
However, it is correct that Qemu create the ACPI tables for the devices it emulates for the guest.
Quoted 8 lines
We need to agree on a mechanism whereby each entity can provide their own subset of the ACPI tables to HVMLoader, and have HVMLoader present the final set properly to the VM.
There is an existing usecase of passing the Host SLIC table to a VM, for OEM Versions of Windows. I believe this is achieved with HVM_XS_ACPI_PT_{ADDRESS,LENGTH}, but that mechanism is a little inflexible and could probably do with being made a little more generic.
A while back I added a generic mechanism to load extra ACPI tables into a guest, configurable at runtime. It looks like the functionality is still present. That might be an option.
Quoted 8 lines
Also, following the thread, it wasn't clear if some of the tables like the SSDT for the NVDIMM device and it's _FIT/_DSM methods were something that could be statically created at build time. If it is something that needs to be generated at runtime (e.g. platform specific), I have a library that can generate any AML on the fly and create SSDTs.
Anyway just FYI in case this is helpful.
Hi Ross,
Thanks for the information!
SSDT for NVDIMM devices can not be created statically, because the number of some items in it can not be determined at build time. For example, the number of NVDIMM ACPI namespace devices (
_DSMis under it) defined in SSDT is determined by the number of vNVDIMM devices in domain configuration. FYI, a sample SSDT for NVDIMM looks likeScope (\_SB){ Device (NVDR) // NVDIMM Root device { Name (_HID, “ACPI0012”) Method (_STA) {...} Method (_FIT) {...} Method (_DSM, ...) { ... } }Device (NVD0) // 1st NVDIMM Device { Name(_ADR, h0) Method (_DSM, ...) { ... } } Device (NVD1) // 2nd NVDIMM Device { Name(_ADR, h1) Method (_DSM, ...) { ... } } ...
Quoted 1 line
}
Makes sense.
Quoted 6 lines
I had ported QEMU's AML builder code as well as NVDIMM ACPI building code to hvmloader and it did work, but then there was too much duplicated code for vNVDIMM between QEMU and hvmloader for vNVDIMM. Therefore, I prefer to let QEMU that emulates vNVDIMM devices to build those tables, as in Andrew and Jan's replies.
Yea it looks like QEUM's AML generating code is quite complete nowadays. Back when I wrote my library there wasn't really much out there. Anyway this is where it is if there is something that I might generate that is missing:
https://github.com/OpenXT/xctools/tree/master/libxenacpi
Quoted 4 lines
Thanks,
Haozhong
Signature · 1 line
Ross Philipson
Quoted 66 lines · Haozhong Zhang
Quoted 56 lines · Stefano Stabellini
Haozhong, thanks for your work!
Quoted 53 lines · Haozhong Zhang
3.2 Address Mapping
3.2.1 My Design
The overview of this design is shown in the following figure.
Dom0 | DomU | | QEMU | +...+--------------------+...+-----+ | VA | | Label Storage Area | | buf | | +...+--------------------+...+-----+ | ^ ^ ^ | | | | | V | | | +-------+ +-------+ mmap(2) | | vACPI | | v_DSM | | | | +----+------------+ +-------+ +-------+ | | | SPA | | /dev/pmem0 | ^ ^ +------+ | | +----+------------+ --------|-----------|-----|------------|-- | ^ ^ | | | | | | | | +------+ +------------~-----~-------------+ | | | | | | XEN_DOMCTL_memory_mapping | | | +-----~--------------------------+ | | | | | | | +----+------------+ | Linux | | SPA | | /dev/pmem0 | | +------+ +------+ | | +----+------------+ | | ACPI | | _DSM | | | ^ | +------+ +------+ | | | | | | | | Dom0 Driver | hvmloader/xl | --------|----|-------------------|---------------------|----------|--------------- | +-------------------~---------------------~----------+ Xen | | | +------------------------~---------------------+ ---------------------------------|------------------------------------------------ +----------------+ | +-------------+ HW | NVDIMM | +-------------+This design treats host NVDIMM devices as ordinary MMIO devices:
(1) Dom0 Linux NVDIMM driver is responsible to detect (through NFIT) and drive host NVDIMM devices (implementing block device interface). Namespaces and file systems on host NVDIMM devices are handled by Dom0 Linux as well.(2) QEMU mmap(2) the pmem NVDIMM devices (
/dev/pmem0) into its virtual address space (buf).Quoted 8 lines
Quoted 3 lines
(3) QEMU gets the host physical address of buf, i.e. the host system physical address that is occupied by
/dev/pmem0, and calls Xen hypercallXEN_DOMCTL_memory_mappingto map it to a DomU.How is this going to work from a security perspective? Is it going to require running QEMU as root in Dom0, which will prevent NVDIMM from working by default on Xen? If so, what's the plan?
Quoted 5 lines
Oh, I forgot to address the non-root qemu issues in this design ...
The default user:group of
/dev/pmem0is root:disk, and its permission is rw-rw----. We could lift the others permission to rw, so that non-root QEMU can mmap/dev/pmem0. But it looks too risky.
Yep, too risky.
Quoted 4 lines
Or, we can make a file system on
/dev/pmem0, create files on it, set the owner of those files to xen-qemuuser-domid$domid, and then pass those files to QEMU. In this way, non-root QEMU should be able to mmap those files.
Maybe that would work. Worth adding it to the design, I would like to read more details on it.
Also note that QEMU initially runs as root but drops privileges to xen-qemuuser-domid$domid before the guest is started. Initially QEMU *could* mmap /dev/pmem0 while is still running as root, but then it wouldn't work for any devices that need to be mmap'ed at run time (hotplug scenario).
Quoted 16 lines
Quoted 6 lines
Quoted 6 lines
(ACPI part is described in Section 3.3 later)
Above (1)(2) have already been done in current QEMU. Only (3) is needed to implement in QEMU. No change is needed in Xen for address mapping in this design.
Quoted 8 lines
Quoted 5 lines
Open: It seems no system call/ioctl is provided by Linux kernel to
get the physical address from a virtual address. /proc/<qemu_pid>/pagemap provides information of mapping from VA to PA. Is it an acceptable solution to let QEMU parse this file to get the physical address?Does it work in a non-root scenario?
Seemingly no, according to
Documentation/vm/pagemap.txtin Linux kernel:
Quoted 8 lines
| Since Linux 4.0 only users with the CAP_SYS_ADMIN capability can get PFNs. | In 4.0 and 4.1 opens by unprivileged fail with -EPERM. Starting from | 4.2 the PFN field is zeroed if the user does not have CAP_SYS_ADMIN. | Reason: information about PFNs helps in exploiting Rowhammer vulnerability.A possible alternative is to add a new hypercall similar to
XEN_DOMCTL_memory_mappingbut receiving virtual address as the address parameter and translating to machine address in the hypervisor.
That might work.
Quoted 7 lines
Quoted 7 lines
Quoted 6 lines
Open: For a large pmem, mmap(2) is very possible to not map all SPA
occupied by pmem at the beginning, i.e. QEMU may not be able to get all SPA of pmem from buf (in virtual address space) when callingXEN_DOMCTL_memory_mapping.
Can mmap flagMAP_LOCKEDor mlock(2) be used to enforce the entire pmem being mmaped?
Quoted 7 lines
Quoted 2 lines
Ditto
No. If I take the above alternative for the first open, maybe the new hypercall above can inject page faults into dom0 for the unmapped virtual address so as to enforce dom0 Linux to create the page mapping.
Otherwise you need to use something like the mapcache in QEMU (xen-mapcache.c), which admittedly, given its complexity, would be best to avoid.
Quoted 89 lines
Quoted 44 lines
Quoted 35 lines
3.2.2 Alternative Design
Jan Beulich's comments [7] on my question "why must pmem resource management and partition be done in hypervisor":
| Because that's where memory management belongs. And PMEM, | other than PBLK, is just another form of RAM. | ... | The main issue is that this would imo be a layering violationGeorge Dunlap's comments [8]:
| This is not the case for PMEM. The whole point of PMEM (correct me if
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ used as fungible ram| I'm wrong) is to be used for long-term storage that survives over | reboot. It matters very much that a guest be given the same PRAM | after the host is rebooted that it was given before. It doesn't make | any sense to manage it the way Xen currently manages RAM (i.e., that | you request a page and get whatever Xen happens to give you). | | So if Xen is going to use PMEM, it will have to invent an entirely new | interface for guests, and it will have to keep track of those | resources across host reboots. In other words, it will have to | duplicate all the work that Linux already does. What do we gain from | that duplication? Why not just leverage what's already implemented in | dom0? and [9]: | Oh, right -- yes, if the usage model of PRAM is just "cheap slow RAM", | then you're right -- it is just another form of RAM, that should be | treated no differently than say, lowmem: a fungible resource that can be | requested by setting a flag.However, pmem is used more as persistent storage than fungible ram, and my design is for the former usage. I would like to leave the detection, driver and partition (either through namespace or file systems) of NVDIMM in Dom0 Linux kernel.
Quoted 5 lines
I notice that current
XEN_DOMCTL_memory_mappingdoes not make santiy check for the physical address and size passed from caller (QEMU). Can QEMU be always trusted? If not, we would need to make Xen aware of the SPA range of pmem so that it can refuse map physical address in neither the normal ram nor pmem.Indeed
[...]
Quoted 44 lines
Quoted 43 lines
3.3 Guest ACPI Emulation
3.3.1 My Design
Guest ACPI emulation is composed of two parts: building guest NFIT and SSDT that defines ACPI namespace devices for NVDIMM, and emulating guest
_DSM.(1) Building Guest ACPI Tables
This design reuses and extends hvmloader's existing mechanism that loads passthrough ACPI tables from binary files to load NFIT and SSDT tables built by QEMU:
1) Because the current QEMU does not building any ACPI tables when it runs as the Xen device model, this design needs to patch QEMU to build NFIT and SSDT (so far only NFIT and SSDT) in this case.2) QEMU copies NFIT and SSDT to the end of guest memory below 4G. The guest address and size of those tables are written into xenstore (/local/domain/domid/hvmloader/dm-acpi/{address,length}).
3) hvmloader is patched to probe and load device model passthrough ACPI tables from above xenstore keys. The detected ACPI tables are then appended to the end of existing guest ACPI tables just like what current
construct_passthrough_tables()does.Reasons for this design are listed below:
- NFIT and SSDT in question are quite self-contained, i.e. they do not refer to other ACPI tables and not conflict with existing guest ACPI tables in Xen. Therefore, it is safe to copy them from QEMU and append to existing guest ACPI tables.- A primary portion of current and future vNVDIMM implementation is about building ACPI tables. And this design also leave the emulation of
_DSMto QEMU which needs to keep consistency with NFIT and SSDT itself builds. Therefore, reusing NFIT and SSDT from QEMU can ease the maintenance.- Anthony's work to pass ACPI tables from the toolstack to hvmloader does not move building SSDT (and NFIT) to toolstack, so this design can still put them in hvmloader.
Quoted 7 lines
Quoted 2 lines
If we start asking QEMU to build ACPI tables, why should we stop at NFIT and SSDT?
for easing my development of supporting vNVDIMM in Xen ... I mean NFIT and SSDT are the only two tables needed for this purpose and I'm afraid to break exiting guests if I completely switch to QEMU for guest ACPI tables.
I realize that my words have been a bit confusing. Not /all/ ACPI tables, just all the tables regarding devices for which QEMU is in charge (the PCI bus and all devices behind it). Anything related to cpus and memory (FADT, MADT, etc) would still be left to hvmloader.
Quoted 3 lines · Stefano Stabellini
Quoted 2 lines · Haozhong Zhang
Quoted 1 line · Stefano Stabellini
On Mon, 1 Feb 2016, Haozhong Zhang wrote:
[...]
Quoted 32 lines
Quoted 18 lines
Quoted 9 lines
Quoted 9 lines
This design treats host NVDIMM devices as ordinary MMIO devices:
(1) Dom0 Linux NVDIMM driver is responsible to detect (through NFIT) and drive host NVDIMM devices (implementing block device interface). Namespaces and file systems on host NVDIMM devices are handled by Dom0 Linux as well.(2) QEMU mmap(2) the pmem NVDIMM devices (
/dev/pmem0) into its virtual address space (buf).Quoted 8 lines
Quoted 3 lines
(3) QEMU gets the host physical address of buf, i.e. the host system physical address that is occupied by
/dev/pmem0, and calls Xen hypercallXEN_DOMCTL_memory_mappingto map it to a DomU.How is this going to work from a security perspective? Is it going to require running QEMU as root in Dom0, which will prevent NVDIMM from working by default on Xen? If so, what's the plan?
Quoted 5 lines
Oh, I forgot to address the non-root qemu issues in this design ...
The default user:group of
/dev/pmem0is root:disk, and its permission is rw-rw----. We could lift the others permission to rw, so that non-root QEMU can mmap/dev/pmem0. But it looks too risky.Yep, too risky.
Quoted 4 lines
Or, we can make a file system on
/dev/pmem0, create files on it, set the owner of those files to xen-qemuuser-domid$domid, and then pass those files to QEMU. In this way, non-root QEMU should be able to mmap those files.
Quoted 9 lines
Maybe that would work. Worth adding it to the design, I would like to read more details on it.
Also note that QEMU initially runs as root but drops privileges to xen-qemuuser-domid$domid before the guest is started. Initially QEMU *could* mmap
/dev/pmem0while is still running as root, but then it wouldn't work for any devices that need to be mmap'ed at run time (hotplug scenario).
Thanks for this information. I'll test some experimental code and then post a design to address the non-root qemu issue.
Quoted 39 lines
Quoted 17 lines
Quoted 7 lines
Quoted 7 lines
(ACPI part is described in Section 3.3 later)
Above (1)(2) have already been done in current QEMU. Only (3) is needed to implement in QEMU. No change is needed in Xen for address mapping in this design.
Quoted 8 lines
Quoted 5 lines
Open: It seems no system call/ioctl is provided by Linux kernel to
get the physical address from a virtual address. /proc/<qemu_pid>/pagemap provides information of mapping from VA to PA. Is it an acceptable solution to let QEMU parse this file to get the physical address?Does it work in a non-root scenario?
Seemingly no, according to
Documentation/vm/pagemap.txtin Linux kernel:Quoted 8 lines
| Since Linux 4.0 only users with the CAP_SYS_ADMIN capability can get PFNs. | In 4.0 and 4.1 opens by unprivileged fail with -EPERM. Starting from | 4.2 the PFN field is zeroed if the user does not have CAP_SYS_ADMIN. | Reason: information about PFNs helps in exploiting Rowhammer vulnerability.A possible alternative is to add a new hypercall similar to
XEN_DOMCTL_memory_mappingbut receiving virtual address as the address parameter and translating to machine address in the hypervisor.That might work.
Quoted 10 lines
Quoted 9 lines
Quoted 6 lines
Open: For a large pmem, mmap(2) is very possible to not map all SPA
occupied by pmem at the beginning, i.e. QEMU may not be able to get all SPA of pmem from buf (in virtual address space) when callingXEN_DOMCTL_memory_mapping.
Can mmap flagMAP_LOCKEDor mlock(2) be used to enforce the entire pmem being mmaped?Ditto
Quoted 9 lines
Quoted 4 lines
No. If I take the above alternative for the first open, maybe the new hypercall above can inject page faults into dom0 for the unmapped virtual address so as to enforce dom0 Linux to create the page mapping.
Otherwise you need to use something like the mapcache in QEMU (
xen-mapcache.c), which admittedly, given its complexity, would be best to avoid.
Definitely not mapcache like things. What I want is something similar to what emulate_gva_to_mfn() in Xen does.
[...]
Quoted 8 lines
Quoted 7 lines
Quoted 2 lines
If we start asking QEMU to build ACPI tables, why should we stop at NFIT and SSDT?
for easing my development of supporting vNVDIMM in Xen ... I mean NFIT and SSDT are the only two tables needed for this purpose and I'm afraid to break exiting guests if I completely switch to QEMU for guest ACPI tables.
Quoted 4 lines
I realize that my words have been a bit confusing. Not /all/ ACPI tables, just all the tables regarding devices for which QEMU is in charge (the PCI bus and all devices behind it). Anything related to cpus and memory (FADT, MADT, etc) would still be left to hvmloader.
OK, then it's clear for me. From Jan's reply, at least MCFG is from QEMU. I'll look at whether other PCI related tables are also from QEMU or similar to those in QEMU. If yes, then it looks reasonable to let QEMU generate them.
Thanks,
Haozhong
Quoted 82 lines · Haozhong Zhang
Quoted 3 lines · Stefano Stabellini
Quoted 2 lines · Haozhong Zhang
Quoted 1 line · Stefano Stabellini
On Mon, 1 Feb 2016, Haozhong Zhang wrote:
[...]
Quoted 28 lines
Quoted 16 lines
Quoted 9 lines
Quoted 9 lines
This design treats host NVDIMM devices as ordinary MMIO devices:
(1) Dom0 Linux NVDIMM driver is responsible to detect (through NFIT) and drive host NVDIMM devices (implementing block device interface). Namespaces and file systems on host NVDIMM devices are handled by Dom0 Linux as well.(2) QEMU mmap(2) the pmem NVDIMM devices (
/dev/pmem0) into its virtual address space (buf).Quoted 7 lines
Quoted 3 lines
(3) QEMU gets the host physical address of buf, i.e. the host system physical address that is occupied by
/dev/pmem0, and calls Xen hypercallXEN_DOMCTL_memory_mappingto map it to a DomU.How is this going to work from a security perspective? Is it going to require running QEMU as root in Dom0, which will prevent NVDIMM from working by default on Xen? If so, what's the plan?
Quoted 5 lines
Oh, I forgot to address the non-root qemu issues in this design ...
The default user:group of
/dev/pmem0is root:disk, and its permission is rw-rw----. We could lift the others permission to rw, so that non-root QEMU can mmap/dev/pmem0. But it looks too risky.Yep, too risky.
Quoted 4 lines
Or, we can make a file system on
/dev/pmem0, create files on it, set the owner of those files to xen-qemuuser-domid$domid, and then pass those files to QEMU. In this way, non-root QEMU should be able to mmap those files.Quoted 9 lines
Maybe that would work. Worth adding it to the design, I would like to read more details on it.
Also note that QEMU initially runs as root but drops privileges to xen-qemuuser-domid$domid before the guest is started. Initially QEMU *could* mmap
/dev/pmem0while is still running as root, but then it wouldn't work for any devices that need to be mmap'ed at run time (hotplug scenario).Thanks for this information. I'll test some experimental code and then post a design to address the non-root qemu issue.
Quoted 37 lines
Quoted 14 lines
Quoted 6 lines
Quoted 6 lines
(ACPI part is described in Section 3.3 later)
Above (1)(2) have already been done in current QEMU. Only (3) is needed to implement in QEMU. No change is needed in Xen for address mapping in this design.
Quoted 7 lines
Quoted 5 lines
Open: It seems no system call/ioctl is provided by Linux kernel to
get the physical address from a virtual address. /proc/<qemu_pid>/pagemap provides information of mapping from VA to PA. Is it an acceptable solution to let QEMU parse this file to get the physical address?Does it work in a non-root scenario?
Seemingly no, according to
Documentation/vm/pagemap.txtin Linux kernel:Quoted 8 lines
| Since Linux 4.0 only users with the CAP_SYS_ADMIN capability can get PFNs. | In 4.0 and 4.1 opens by unprivileged fail with -EPERM. Starting from | 4.2 the PFN field is zeroed if the user does not have CAP_SYS_ADMIN. | Reason: information about PFNs helps in exploiting Rowhammer vulnerability.A possible alternative is to add a new hypercall similar to
XEN_DOMCTL_memory_mappingbut receiving virtual address as the address parameter and translating to machine address in the hypervisor.That might work.
Quoted 12 lines
Quoted 8 lines
Quoted 6 lines
Open: For a large pmem, mmap(2) is very possible to not map all SPA
occupied by pmem at the beginning, i.e. QEMU may not be able to get all SPA of pmem from buf (in virtual address space) when callingXEN_DOMCTL_memory_mapping.
Can mmap flagMAP_LOCKEDor mlock(2) be used to enforce the entire pmem being mmaped?Ditto
No. If I take the above alternative for the first open, maybe the new hypercall above can inject page faults into dom0 for the unmapped virtual address so as to enforce dom0 Linux to create the page mapping.
Quoted 6 lines
Quoted 4 lines
Otherwise you need to use something like the mapcache in QEMU (
xen-mapcache.c), which admittedly, given its complexity, would be best to avoid.Definitely not mapcache like things. What I want is something similar to what
emulate_gva_to_mfn()in Xen does.
Please not quite like that. It would restrict this to only working in a PV dom0.
MFNs are an implementation detail. Interfaces should take GFNs which are consistent logical meaning between PV and HVM domains.
As an introduction,
http://xenbits.xen.org/gitweb/?p=xen.git;a=blob;f=xen/include/xen/mm.h;h=a795dd6001eff7c5dd942bbaf153e3efa5202318;hb=refs/heads/staging#l8
We also need to consider the Xen side security. Currently a domain may be given privilege to map an MMIO range. IIRC, this allows the emulator domain to make mappings for the guest, and for the guest to make mappings itself. With PMEM, we can't allow a domain to make mappings itself because it could end up mapping resources which belong to another domain. We probably need an intermediate level which only permits an emulator to make the mappings.
Quoted 8 lines
[...]
Quoted 6 lines
Quoted 6 lines
Quoted 2 lines
If we start asking QEMU to build ACPI tables, why should we stop at NFIT and SSDT?
for easing my development of supporting vNVDIMM in Xen ... I mean NFIT and SSDT are the only two tables needed for this purpose and I'm afraid to break exiting guests if I completely switch to QEMU for guest ACPI tables.
Quoted 8 lines
Quoted 4 lines
I realize that my words have been a bit confusing. Not /all/ ACPI tables, just all the tables regarding devices for which QEMU is in charge (the PCI bus and all devices behind it). Anything related to cpus and memory (FADT, MADT, etc) would still be left to hvmloader.
OK, then it's clear for me. From Jan's reply, at least MCFG is from QEMU. I'll look at whether other PCI related tables are also from QEMU or similar to those in QEMU. If yes, then it looks reasonable to let QEMU generate them.
It is entirely likely that the current split of sources of APCI tables is incorrect. We should also see what can be done about fixing that.
~Andrew
Quoted 41 lines · Andrew Cooper
Quoted 41 lines
Quoted 41 lines
Quoted 14 lines
Quoted 6 lines
Quoted 6 lines
(ACPI part is described in Section 3.3 later)
Above (1)(2) have already been done in current QEMU. Only (3) is needed to implement in QEMU. No change is needed in Xen for address mapping in this design.
Quoted 7 lines
Quoted 5 lines
Open: It seems no system call/ioctl is provided by Linux kernel to
get the physical address from a virtual address. /proc/<qemu_pid>/pagemap provides information of mapping from VA to PA. Is it an acceptable solution to let QEMU parse this file to get the physical address?Does it work in a non-root scenario?
Seemingly no, according to
Documentation/vm/pagemap.txtin Linux kernel:Quoted 8 lines
| Since Linux 4.0 only users with the CAP_SYS_ADMIN capability can get PFNs. | In 4.0 and 4.1 opens by unprivileged fail with -EPERM. Starting from | 4.2 the PFN field is zeroed if the user does not have CAP_SYS_ADMIN. | Reason: information about PFNs helps in exploiting Rowhammer vulnerability.A possible alternative is to add a new hypercall similar to
XEN_DOMCTL_memory_mappingbut receiving virtual address as the address parameter and translating to machine address in the hypervisor.That might work.
Quoted 6 lines
Quoted 6 lines
Quoted 6 lines
Open: For a large pmem, mmap(2) is very possible to not map all SPA
occupied by pmem at the beginning, i.e. QEMU may not be able to get all SPA of pmem from buf (in virtual address space) when callingXEN_DOMCTL_memory_mapping.
Can mmap flagMAP_LOCKEDor mlock(2) be used to enforce the entire pmem being mmaped?Quoted 6 lines
Quoted 2 lines
Ditto
No. If I take the above alternative for the first open, maybe the new hypercall above can inject page faults into dom0 for the unmapped virtual address so as to enforce dom0 Linux to create the page mapping.
Otherwise you need to use something like the mapcache in QEMU (
xen-mapcache.c), which admittedly, given its complexity, would be best to avoid.
Quoted 7 lines
Quoted 2 lines
Definitely not mapcache like things. What I want is something similar to what
emulate_gva_to_mfn()in Xen does.Please not quite like that. It would restrict this to only working in a PV dom0.
MFNs are an implementation detail.
I don't get this point.
What do you mean by 'implementation detail'? Architectural differences?
Quoted 6 lines
Interfaces should take GFNs which
are consistent logical meaning between PV and HVM domains.As an introduction,
http://xenbits.xen.org/gitweb/?p=xen.git;a=blob;f=xen/include/xen/mm.h;h=a795dd6001eff7c5dd942bbaf153e3efa5202318;hb=refs/heads/staging#l8
Quoted 8 lines
We also need to consider the Xen side security. Currently a domain may be given privilege to map an MMIO range. IIRC, this allows the emulator domain to make mappings for the guest, and for the guest to make mappings itself. With PMEM, we can't allow a domain to make mappings itself because it could end up mapping resources which belong to another domain. We probably need an intermediate level which only permits an emulator to make the mappings.
agree, this hypercall should not be called by arbitrary domains. Any existing mechanism in Xen to restrict callers of hypercalls?
Quoted 12 lines
Quoted 12 lines
[...]
Quoted 10 lines
Quoted 6 lines
Quoted 2 lines
If we start asking QEMU to build ACPI tables, why should we stop at NFIT and SSDT?
for easing my development of supporting vNVDIMM in Xen ... I mean NFIT and SSDT are the only two tables needed for this purpose and I'm afraid to break exiting guests if I completely switch to QEMU for guest ACPI tables.
I realize that my words have been a bit confusing. Not /all/ ACPI tables, just all the tables regarding devices for which QEMU is in charge (the PCI bus and all devices behind it). Anything related to cpus and memory (FADT, MADT, etc) would still be left to hvmloader.
Quoted 8 lines
Quoted 4 lines
OK, then it's clear for me. From Jan's reply, at least MCFG is from QEMU. I'll look at whether other PCI related tables are also from QEMU or similar to those in QEMU. If yes, then it looks reasonable to let QEMU generate them.
It is entirely likely that the current split of sources of APCI tables is incorrect. We should also see what can be done about fixing that.
How about Jan's comment
| tables should come from qemu for components living in qemu, and from | hvmloader for components coming from Xen
Thanks,
Haozhong
Quoted 6 lines · Stefano Stabellini
Quoted 4 lines · Haozhong Zhang
Or, we can make a file system on
/dev/pmem0, create files on it, set the owner of those files to xen-qemuuser-domid$domid, and then pass those files to QEMU. In this way, non-root QEMU should be able to mmap those files.
Quoted 8 lines
Maybe that would work. Worth adding it to the design, I would like to read more details on it.
Also note that QEMU initially runs as root but drops privileges to xen-qemuuser-domid$domid before the guest is started. Initially QEMU *could* mmap
/dev/pmem0while is still running as root, but then it wouldn't work for any devices that need to be mmap'ed at run time (hotplug scenario).
This is basically the same problem we have for a bunch of other things, right? Having xl open a file and then pass it via qmp to qemu should work in theory, right?
-George
Quoted 16 lines · George Dunlap
Quoted 6 lines · Stefano Stabellini
Quoted 4 lines · Haozhong Zhang
Or, we can make a file system on
/dev/pmem0, create files on it, set the owner of those files to xen-qemuuser-domid$domid, and then pass those files to QEMU. In this way, non-root QEMU should be able to mmap those files.Quoted 8 lines
Maybe that would work. Worth adding it to the design, I would like to read more details on it.
Also note that QEMU initially runs as root but drops privileges to xen-qemuuser-domid$domid before the guest is started. Initially QEMU *could* mmap
/dev/pmem0while is still running as root, but then it wouldn't work for any devices that need to be mmap'ed at run time (hotplug scenario).
Quoted 3 lines
This is basically the same problem we have for a bunch of other things, right? Having xl open a file and then pass it via qmp to qemu should work in theory, right?
Is there one /dev/pmem? per assignable region? Otherwise it wouldn't be safe.
Quoted 17 lines · Stefano Stabellini
Quoted 16 lines · George Dunlap
Quoted 14 lines · Stefano Stabellini
Quoted 4 lines · Haozhong Zhang
Or, we can make a file system on
/dev/pmem0, create files on it, set the owner of those files to xen-qemuuser-domid$domid, and then pass those files to QEMU. In this way, non-root QEMU should be able to mmap those files.Maybe that would work. Worth adding it to the design, I would like to read more details on it.
Also note that QEMU initially runs as root but drops privileges to xen-qemuuser-domid$domid before the guest is started. Initially QEMU *could* mmap
/dev/pmem0while is still running as root, but then it wouldn't work for any devices that need to be mmap'ed at run time (hotplug scenario).
Quoted 6 lines
Quoted 3 lines
This is basically the same problem we have for a bunch of other things, right? Having xl open a file and then pass it via qmp to qemu should work in theory, right?
Is there one
/dev/pmem? per assignable region? Otherwise it wouldn't be safe.
Can be - which may be interleaved on multiple NVDIMMs. But we would operate on files (on the /dev/pmem which has an DAX enabled filesystem).
Quoted 17 lines · Stefano Stabellini
Quoted 16 lines · George Dunlap
Quoted 14 lines · Stefano Stabellini
Quoted 4 lines · Haozhong Zhang
Or, we can make a file system on
/dev/pmem0, create files on it, set the owner of those files to xen-qemuuser-domid$domid, and then pass those files to QEMU. In this way, non-root QEMU should be able to mmap those files.Maybe that would work. Worth adding it to the design, I would like to read more details on it.
Also note that QEMU initially runs as root but drops privileges to xen-qemuuser-domid$domid before the guest is started. Initially QEMU *could* mmap
/dev/pmem0while is still running as root, but then it wouldn't work for any devices that need to be mmap'ed at run time (hotplug scenario).
Quoted 6 lines
Quoted 3 lines
This is basically the same problem we have for a bunch of other things, right? Having xl open a file and then pass it via qmp to qemu should work in theory, right?
Is there one
/dev/pmem? per assignable region? Otherwise it wouldn't be safe.
If I understood Haozhong's description right, you'd be passing through the entirety of one thing that Linux gave you. At the moment that'sone /dev/pmemX, which at the moment corresponds to one region as specified in the ACPI tables. I understood his design going forward to mean that it would rely on Linux to do any further partitioning within regions if that was desired; in which case there would again be a single file that qemu would have access to.
-George
Quoted 17 lines · Stefano Stabellini
Quoted 16 lines · George Dunlap
Quoted 14 lines · Stefano Stabellini
Quoted 4 lines · Haozhong Zhang
Or, we can make a file system on
/dev/pmem0, create files on it, set the owner of those files to xen-qemuuser-domid$domid, and then pass those files to QEMU. In this way, non-root QEMU should be able to mmap those files.Maybe that would work. Worth adding it to the design, I would like to read more details on it.
Also note that QEMU initially runs as root but drops privileges to xen-qemuuser-domid$domid before the guest is started. Initially QEMU *could* mmap
/dev/pmem0while is still running as root, but then it wouldn't work for any devices that need to be mmap'ed at run time (hotplug scenario).
Quoted 5 lines
Quoted 3 lines
This is basically the same problem we have for a bunch of other things, right? Having xl open a file and then pass it via qmp to qemu should work in theory, right?
Is there one
/dev/pmem? per assignable region?
Yes.
BTW, I'm wondering whether and how non-root qemu works with xl disk configuration that is going to access a host block device, e.g.
disk = [ '/dev/sdb,,hda' ]
If that works with non-root qemu, I may take the similar solution for pmem.
Thanks,
Haozhong
Quoted 1 line
Otherwise it wouldn't be safe.
Quoted 24 lines · Haozhong Zhang
Quoted 17 lines · Stefano Stabellini
Quoted 16 lines · George Dunlap
Quoted 14 lines · Stefano Stabellini
Quoted 4 lines · Haozhong Zhang
Or, we can make a file system on
/dev/pmem0, create files on it, set the owner of those files to xen-qemuuser-domid$domid, and then pass those files to QEMU. In this way, non-root QEMU should be able to mmap those files.Maybe that would work. Worth adding it to the design, I would like to read more details on it.
Also note that QEMU initially runs as root but drops privileges to xen-qemuuser-domid$domid before the guest is started. Initially QEMU *could* mmap
/dev/pmem0while is still running as root, but then it wouldn't work for any devices that need to be mmap'ed at run time (hotplug scenario).Quoted 5 lines
Quoted 3 lines
This is basically the same problem we have for a bunch of other things, right? Having xl open a file and then pass it via qmp to qemu should work in theory, right?
Is there one
/dev/pmem? per assignable region?
Quoted 7 lines
Yes.
BTW, I'm wondering whether and how non-root qemu works with xl disk configuration that is going to access a host block device, e.g.
disk = [ '/dev/sdb,,hda' ]If that works with non-root qemu, I may take the similar solution for pmem.
Today the user is required to give the correct ownership and access mode to the block device, so that non-root QEMU can open it. However in the case of PCI passthrough, QEMU needs to mmap /dev/mem, as a consequence the feature doesn't work at all with non-root QEMU
(http://marc.info/?l=xen-devel&m=145261763600528).
If there is one /dev/pmem device per assignable region, then it would be conceivable to change its ownership so that non-root QEMU can open it. Or, better, the file descriptor could be passed by the toolstack via qmp.
Quoted 39 lines · Stefano Stabellini
Quoted 24 lines · Haozhong Zhang
Quoted 17 lines · Stefano Stabellini
Quoted 16 lines · George Dunlap
Quoted 14 lines · Stefano Stabellini
Quoted 4 lines · Haozhong Zhang
Or, we can make a file system on
/dev/pmem0, create files on it, set the owner of those files to xen-qemuuser-domid$domid, and then pass those files to QEMU. In this way, non-root QEMU should be able to mmap those files.Maybe that would work. Worth adding it to the design, I would like to read more details on it.
Also note that QEMU initially runs as root but drops privileges to xen-qemuuser-domid$domid before the guest is started. Initially QEMU *could* mmap
/dev/pmem0while is still running as root, but then it wouldn't work for any devices that need to be mmap'ed at run time (hotplug scenario).Quoted 5 lines
Quoted 3 lines
This is basically the same problem we have for a bunch of other things, right? Having xl open a file and then pass it via qmp to qemu should work in theory, right?
Is there one
/dev/pmem? per assignable region?Quoted 7 lines
Yes.
BTW, I'm wondering whether and how non-root qemu works with xl disk configuration that is going to access a host block device, e.g.
disk = [ '/dev/sdb,,hda' ]If that works with non-root qemu, I may take the similar solution for pmem.
Today the user is required to give the correct ownership and access mode to the block device, so that non-root QEMU can open it. However in the case of PCI passthrough, QEMU needs to mmap
/dev/mem, as a consequence the feature doesn't work at all with non-root QEMU
(http://marc.info/?l=xen-devel&m=145261763600528).
Quoted 4 lines
If there is one
/dev/pmemdevice per assignable region, then it would be conceivable to change its ownership so that non-root QEMU can open it. Or, better, the file descriptor could be passed by the toolstack via qmp.
Passing file descriptor via qmp is not enough.
Let me clarify where the requirement for root/privileged permissions comes from. The primary workflow in my design that maps a host pmem region or files in host pmem region to guest is shown as below:
(1) QEMU in Dom0 mmap the host pmem (the host /dev/pmem0 or files on /dev/pmem0) to its virtual address space, i.e. the guest virtual address space.
(2) QEMU asks Xen hypervisor to map the host physical address, i.e. SPA occupied by the host pmem to a DomU. This step requires the translation from the guest virtual address (where the host pmem is mmaped in (1)) to the host physical address. The translation can be done by either
(a) QEMU that parses its own /proc/self/pagemap,
or
(b) Xen hypervisor that does the translation by itself [1] (though this choice is not quite doable from Konrad's comments [2]).
[1] http://lists.xenproject.org/archives/html/xen-devel/2016-02/msg00434.html
[2] http://lists.xenproject.org/archives/html/xen-devel/2016-02/msg00606.html
For 2-a, reading /proc/self/pagemap requires CAP_SYS_ADMIN capability since linux kernel 4.0. Furthermore, if we don't mlock the mapped host pmem (by adding MAP_LOCKED flag to mmap or calling mlock after mmap), pagemap will not contain all mappings. However, mlock may require privileged permission to lock memory larger than RLIMIT_MEMLOCK. Because mlock operates on memory, the permission to open(2) the host pmem files does not solve the problem and therefore passing file descriptor via qmp does not help.
For 2-b, from Konrad's comments [2], mlock is also required and privileged permission may be required consequently.
Note that the mapping and the address translation are done before QEMU dropping privileged permissions, so non-root QEMU should be able to work with above design until we start considering vNVDIMM hotplug (which has not been supported by the current vNVDIMM implementation in QEMU). In the hotplug case, we may let Xen pass explicit flags to QEMU to keep it running with root permissions.
Haozhong
Quoted 78 lines · Haozhong
Quoted 39 lines · Stefano Stabellini
Quoted 24 lines · Haozhong Zhang
Quoted 17 lines · Stefano Stabellini
Quoted 16 lines · George Dunlap
Quoted 14 lines · Stefano Stabellini
Quoted 4 lines · Haozhong Zhang
Or, we can make a file system on
/dev/pmem0, create files on it, set the owner of those files to xen-qemuuser-domid$domid, and then pass those files to QEMU. In this way, non-root QEMU should be able to mmap those files.Maybe that would work. Worth adding it to the design, I would like to read more details on it.
Also note that QEMU initially runs as root but drops privileges to xen-qemuuser-domid$domid before the guest is started. Initially QEMU *could* mmap
/dev/pmem0while is still running as root, but then it wouldn't work for any devices that need to be mmap'ed at run time (hotplug scenario).Quoted 5 lines
Quoted 3 lines
This is basically the same problem we have for a bunch of other things, right? Having xl open a file and then pass it via qmp to qemu should work in theory, right?
Is there one
/dev/pmem? per assignable region?Quoted 7 lines
Yes.
BTW, I'm wondering whether and how non-root qemu works with xl disk configuration that is going to access a host block device, e.g.
disk = [ '/dev/sdb,,hda' ]If that works with non-root qemu, I may take the similar solution for pmem.
Today the user is required to give the correct ownership and access mode to the block device, so that non-root QEMU can open it. However in the case of PCI passthrough, QEMU needs to mmap
/dev/mem, as a consequence the feature doesn't work at all with non-root QEMU
(http://marc.info/?l=xen-devel&m=145261763600528).Quoted 4 lines
If there is one
/dev/pmemdevice per assignable region, then it would be conceivable to change its ownership so that non-root QEMU can open it. Or, better, the file descriptor could be passed by the toolstack via qmp.Passing file descriptor via qmp is not enough.
Let me clarify where the requirement for root/privileged permissions comes from. The primary workflow in my design that maps a host pmem region or files in host pmem region to guest is shown as below:
(1) QEMU in Dom0 mmap the host pmem (the host/dev/pmem0or files on/dev/pmem0) to its virtual address space, i.e. the guest virtual address space.
(2) QEMU asks Xen hypervisor to map the host physical address, i.e. SPA occupied by the host pmem to a DomU. This step requires the translation from the guest virtual address (where the host pmem is mmaped in (1)) to the host physical address. The translation can be done by either
(a) QEMU that parses its own/proc/self/pagemap,
or
(b) Xen hypervisor that does the translation by itself [1] (though this choice is not quite doable from Konrad's comments [2]).[1] http://lists.xenproject.org/archives/html/xen-devel/2016-02/msg00434.html
[2] http://lists.xenproject.org/archives/html/xen-devel/2016-02/msg00606.htmlFor 2-a, reading
/proc/self/pagemaprequiresCAP_SYS_ADMINcapability since linux kernel 4.0. Furthermore, if we don't mlock the mapped host pmem (by addingMAP_LOCKEDflag to mmap or calling mlock after mmap), pagemap will not contain all mappings. However, mlock may require privileged permission to lock memory larger thanRLIMIT_MEMLOCK. Because mlock operates on memory, the permission to open(2) the host pmem files does not solve the problem and therefore passing file descriptor via qmp does not help.For 2-b, from Konrad's comments [2], mlock is also required and privileged permission may be required consequently.
Quoted 6 lines
Note that the mapping and the address translation are done before QEMU dropping privileged permissions, so non-root QEMU should be able to work with above design until we start considering vNVDIMM hotplug (which has not been supported by the current vNVDIMM implementation in QEMU). In the hotplug case, we may let Xen pass explicit flags to QEMU to keep it running with root permissions.
Are we all good with the fact that vNVDIMM hotplug won't work (unless the user explicitly asks for it at domain creation time, which is very unlikely otherwise she could use coldplug)?
If so, the design is OK for me.
Quoted 87 lines
Quoted 1 line
Quoted 1 line · On 16.02.16 at 12:14, <[email protected]> wrote:
Quoted 78 lines · Haozhong
Quoted 39 lines · Stefano Stabellini
Quoted 24 lines · Haozhong Zhang
Quoted 17 lines · Stefano Stabellini
Quoted 16 lines · George Dunlap
Quoted 14 lines · Stefano Stabellini
Quoted 4 lines · Haozhong Zhang
Or, we can make a file system on
/dev/pmem0, create files on it, set the owner of those files to xen-qemuuser-domid$domid, and then pass those files to QEMU. In this way, non-root QEMU should be able to mmap those files.Maybe that would work. Worth adding it to the design, I would like to read more details on it.
Also note that QEMU initially runs as root but drops privileges to xen-qemuuser-domid$domid before the guest is started. Initially QEMU *could* mmap
/dev/pmem0while is still running as root, but then it wouldn't work for any devices that need to be mmap'ed at run time (hotplug scenario).Quoted 5 lines
Quoted 3 lines
This is basically the same problem we have for a bunch of other things, right? Having xl open a file and then pass it via qmp to qemu should work in theory, right?
Is there one
/dev/pmem? per assignable region?Quoted 7 lines
Yes.
BTW, I'm wondering whether and how non-root qemu works with xl disk configuration that is going to access a host block device, e.g.
disk = [ '/dev/sdb,,hda' ]If that works with non-root qemu, I may take the similar solution for pmem.
Today the user is required to give the correct ownership and access mode to the block device, so that non-root QEMU can open it. However in the case of PCI passthrough, QEMU needs to mmap
/dev/mem, as a consequence the feature doesn't work at all with non-root QEMU
(http://marc.info/?l=xen-devel&m=145261763600528).Quoted 4 lines
If there is one
/dev/pmemdevice per assignable region, then it would be conceivable to change its ownership so that non-root QEMU can open it. Or, better, the file descriptor could be passed by the toolstack via qmp.Passing file descriptor via qmp is not enough.
Let me clarify where the requirement for root/privileged permissions comes from. The primary workflow in my design that maps a host pmem region or files in host pmem region to guest is shown as below:
(1) QEMU in Dom0 mmap the host pmem (the host/dev/pmem0or files on/dev/pmem0) to its virtual address space, i.e. the guest virtual address space.
(2) QEMU asks Xen hypervisor to map the host physical address, i.e. SPA occupied by the host pmem to a DomU. This step requires the translation from the guest virtual address (where the host pmem is mmaped in (1)) to the host physical address. The translation can be done by either
(a) QEMU that parses its own/proc/self/pagemap,
or
(b) Xen hypervisor that does the translation by itself [1] (though this choice is not quite doable from Konrad's comments [2]).[1] http://lists.xenproject.org/archives/html/xen-devel/2016-02/msg00434.html
[2] http://lists.xenproject.org/archives/html/xen-devel/2016-02/msg00606.htmlFor 2-a, reading
/proc/self/pagemaprequiresCAP_SYS_ADMINcapability since linux kernel 4.0. Furthermore, if we don't mlock the mapped host pmem (by addingMAP_LOCKEDflag to mmap or calling mlock after mmap), pagemap will not contain all mappings. However, mlock may require privileged permission to lock memory larger thanRLIMIT_MEMLOCK. Because mlock operates on memory, the permission to open(2) the host pmem files does not solve the problem and therefore passing file descriptor via qmp does not help.For 2-b, from Konrad's comments [2], mlock is also required and privileged permission may be required consequently.
Quoted 6 lines
Note that the mapping and the address translation are done before QEMU dropping privileged permissions, so non-root QEMU should be able to work with above design until we start considering vNVDIMM hotplug (which has not been supported by the current vNVDIMM implementation in QEMU). In the hotplug case, we may let Xen pass explicit flags to QEMU to keep it running with root permissions.
Quoted 3 lines
Are we all good with the fact that vNVDIMM hotplug won't work (unless the user explicitly asks for it at domain creation time, which is very unlikely otherwise she could use coldplug)?
No, at least there needs to be a road towards hotplug, even if initially this may not be supported/implemented.
Jan
Quoted 87 lines · Jan Beulich
Quoted 87 lines
Quoted 1 line
Quoted 1 line · On 16.02.16 at 12:14, <[email protected]> wrote:
Quoted 84 lines · Haozhong
Quoted 39 lines · Stefano Stabellini
Quoted 24 lines · Haozhong Zhang
Quoted 17 lines · Stefano Stabellini
Quoted 16 lines · George Dunlap
Quoted 14 lines · Stefano Stabellini
Quoted 4 lines · Haozhong Zhang
Or, we can make a file system on
/dev/pmem0, create files on it, set the owner of those files to xen-qemuuser-domid$domid, and then pass those files to QEMU. In this way, non-root QEMU should be able to mmap those files.Maybe that would work. Worth adding it to the design, I would like to read more details on it.
Also note that QEMU initially runs as root but drops privileges to xen-qemuuser-domid$domid before the guest is started. Initially QEMU *could* mmap
/dev/pmem0while is still running as root, but then it wouldn't work for any devices that need to be mmap'ed at run time (hotplug scenario).Quoted 5 lines
Quoted 3 lines
This is basically the same problem we have for a bunch of other things, right? Having xl open a file and then pass it via qmp to qemu should work in theory, right?
Is there one
/dev/pmem? per assignable region?Quoted 7 lines
Yes.
BTW, I'm wondering whether and how non-root qemu works with xl disk configuration that is going to access a host block device, e.g.
disk = [ '/dev/sdb,,hda' ]If that works with non-root qemu, I may take the similar solution for pmem.
Today the user is required to give the correct ownership and access mode to the block device, so that non-root QEMU can open it. However in the case of PCI passthrough, QEMU needs to mmap
/dev/mem, as a consequence the feature doesn't work at all with non-root QEMU
(http://marc.info/?l=xen-devel&m=145261763600528).Quoted 4 lines
If there is one
/dev/pmemdevice per assignable region, then it would be conceivable to change its ownership so that non-root QEMU can open it. Or, better, the file descriptor could be passed by the toolstack via qmp.Passing file descriptor via qmp is not enough.
Let me clarify where the requirement for root/privileged permissions comes from. The primary workflow in my design that maps a host pmem region or files in host pmem region to guest is shown as below:
(1) QEMU in Dom0 mmap the host pmem (the host/dev/pmem0or files on/dev/pmem0) to its virtual address space, i.e. the guest virtual address space.
(2) QEMU asks Xen hypervisor to map the host physical address, i.e. SPA occupied by the host pmem to a DomU. This step requires the translation from the guest virtual address (where the host pmem is mmaped in (1)) to the host physical address. The translation can be done by either
(a) QEMU that parses its own/proc/self/pagemap,
or
(b) Xen hypervisor that does the translation by itself [1] (though this choice is not quite doable from Konrad's comments [2]).[1] http://lists.xenproject.org/archives/html/xen-devel/2016-02/msg00434.html
[2] http://lists.xenproject.org/archives/html/xen-devel/2016-02/msg00606.htmlFor 2-a, reading
/proc/self/pagemaprequiresCAP_SYS_ADMINcapability since linux kernel 4.0. Furthermore, if we don't mlock the mapped host pmem (by addingMAP_LOCKEDflag to mmap or calling mlock after mmap), pagemap will not contain all mappings. However, mlock may require privileged permission to lock memory larger thanRLIMIT_MEMLOCK. Because mlock operates on memory, the permission to open(2) the host pmem files does not solve the problem and therefore passing file descriptor via qmp does not help.For 2-b, from Konrad's comments [2], mlock is also required and privileged permission may be required consequently.
Note that the mapping and the address translation are done before QEMU dropping privileged permissions, so non-root QEMU should be able to work with above design until we start considering vNVDIMM hotplug (which has not been supported by the current vNVDIMM implementation in QEMU). In the hotplug case, we may let Xen pass explicit flags to QEMU to keep it running with root permissions.
Quoted 6 lines
Quoted 3 lines
Are we all good with the fact that vNVDIMM hotplug won't work (unless the user explicitly asks for it at domain creation time, which is very unlikely otherwise she could use coldplug)?
No, at least there needs to be a road towards hotplug, even if initially this may not be supported/implemented.
Guangrong: any plan or design for vNVDIMM hotplug in QEMU?
Haozhong
Quoted 87 lines · Jan Beulich
Quoted 87 lines
Quoted 1 line
Quoted 1 line · On 16.02.16 at 12:14, <[email protected]> wrote:
Quoted 84 lines · Haozhong
Quoted 39 lines · Stefano Stabellini
Quoted 24 lines · Haozhong Zhang
Quoted 17 lines · Stefano Stabellini
Quoted 16 lines · George Dunlap
Quoted 14 lines · Stefano Stabellini
Quoted 4 lines · Haozhong Zhang
Or, we can make a file system on
/dev/pmem0, create files on it, set the owner of those files to xen-qemuuser-domid$domid, and then pass those files to QEMU. In this way, non-root QEMU should be able to mmap those files.Maybe that would work. Worth adding it to the design, I would like to read more details on it.
Also note that QEMU initially runs as root but drops privileges to xen-qemuuser-domid$domid before the guest is started. Initially QEMU *could* mmap
/dev/pmem0while is still running as root, but then it wouldn't work for any devices that need to be mmap'ed at run time (hotplug scenario).Quoted 5 lines
Quoted 3 lines
This is basically the same problem we have for a bunch of other things, right? Having xl open a file and then pass it via qmp to qemu should work in theory, right?
Is there one
/dev/pmem? per assignable region?Quoted 7 lines
Yes.
BTW, I'm wondering whether and how non-root qemu works with xl disk configuration that is going to access a host block device, e.g.
disk = [ '/dev/sdb,,hda' ]If that works with non-root qemu, I may take the similar solution for pmem.
Today the user is required to give the correct ownership and access mode to the block device, so that non-root QEMU can open it. However in the case of PCI passthrough, QEMU needs to mmap
/dev/mem, as a consequence the feature doesn't work at all with non-root QEMU
(http://marc.info/?l=xen-devel&m=145261763600528).Quoted 4 lines
If there is one
/dev/pmemdevice per assignable region, then it would be conceivable to change its ownership so that non-root QEMU can open it. Or, better, the file descriptor could be passed by the toolstack via qmp.Passing file descriptor via qmp is not enough.
Let me clarify where the requirement for root/privileged permissions comes from. The primary workflow in my design that maps a host pmem region or files in host pmem region to guest is shown as below:
(1) QEMU in Dom0 mmap the host pmem (the host/dev/pmem0or files on/dev/pmem0) to its virtual address space, i.e. the guest virtual address space.
(2) QEMU asks Xen hypervisor to map the host physical address, i.e. SPA occupied by the host pmem to a DomU. This step requires the translation from the guest virtual address (where the host pmem is mmaped in (1)) to the host physical address. The translation can be done by either
(a) QEMU that parses its own/proc/self/pagemap,
or
(b) Xen hypervisor that does the translation by itself [1] (though this choice is not quite doable from Konrad's comments [2]).[1] http://lists.xenproject.org/archives/html/xen-devel/2016-02/msg00434.html
[2] http://lists.xenproject.org/archives/html/xen-devel/2016-02/msg00606.htmlFor 2-a, reading
/proc/self/pagemaprequiresCAP_SYS_ADMINcapability since linux kernel 4.0. Furthermore, if we don't mlock the mapped host pmem (by addingMAP_LOCKEDflag to mmap or calling mlock after mmap), pagemap will not contain all mappings. However, mlock may require privileged permission to lock memory larger thanRLIMIT_MEMLOCK. Because mlock operates on memory, the permission to open(2) the host pmem files does not solve the problem and therefore passing file descriptor via qmp does not help.For 2-b, from Konrad's comments [2], mlock is also required and privileged permission may be required consequently.
Note that the mapping and the address translation are done before QEMU dropping privileged permissions, so non-root QEMU should be able to work with above design until we start considering vNVDIMM hotplug (which has not been supported by the current vNVDIMM implementation in QEMU). In the hotplug case, we may let Xen pass explicit flags to QEMU to keep it running with root permissions.
Quoted 7 lines
Quoted 3 lines
Are we all good with the fact that vNVDIMM hotplug won't work (unless the user explicitly asks for it at domain creation time, which is very unlikely otherwise she could use coldplug)?
No, at least there needs to be a road towards hotplug, even if initially this may not be supported/implemented.
Suddenly realize it's unnecessary to let QEMU get SPA ranges of NVDIMM or files on NVDIMM. We can move that work to toolstack and pass SPA ranges got by toolstack to qemu. In this way, no privileged operations (mmap/mlock/...) are needed in QEMU and non-root QEMU should be able to work even with vNVDIMM hotplug in future.
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Hi Jan and Konrad,
Quoted 6 lines · Haozhong Zhang
Suddenly realize it's unnecessary to let QEMU get SPA ranges of NVDIMM or files on NVDIMM. We can move that work to toolstack and pass SPA ranges got by toolstack to qemu. In this way, no privileged operations (mmap/mlock/...) are needed in QEMU and non-root QEMU should be able to work even with vNVDIMM hotplug in future.
As I'm going to let toolstack to get NVDIMM SPA ranges. This can be done via dom0 kernel interface and xen hypercalls, and can be implemented in different ways. I'm wondering which of the following ones is preferred by xen.
1. Given
* a file descriptor of either a NVDIMM device or a file on NVDIMM, and
* domain id and guest MFN where vNVDIMM is going to be.
xen toolstack (1) gets it SPA ranges via dom0 kernel interface (e.g. sysfs and ioctl FIEMAP), and (2) calls a hypercall to map above SPA ranges to the given guest MFN of the given domain.
2. Or, given the same inputs, we may combine above two steps into a new dom0 system call that (1) gets the SPA ranges, (2) calls xen hypercall to map SPA ranges, and, one step further, (3) returns SPA ranges to userspace (because QEMU needs these addresses to build ACPI).
The first way does not need to modify dom0 linux kernel, while the second requires a new system call. I'm not sure whether xen toolstack as a userspace program is considered to be safe to pass the host physical address to hypervisor. If not, maybe the second one is better?
Thanks,
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 27 lines · Haozhong Zhang
Hi Jan and Konrad,
Quoted 6 lines · Haozhong Zhang
Suddenly realize it's unnecessary to let QEMU get SPA ranges of NVDIMM or files on NVDIMM. We can move that work to toolstack and pass SPA ranges got by toolstack to qemu. In this way, no privileged operations (mmap/mlock/...) are needed in QEMU and non-root QEMU should be able to work even with vNVDIMM hotplug in future.
As I'm going to let toolstack to get NVDIMM SPA ranges. This can be done via dom0 kernel interface and xen hypercalls, and can be implemented in different ways. I'm wondering which of the following ones is preferred by xen.
1. Given
* a file descriptor of either a NVDIMM device or a file on NVDIMM, and
* domain id and guest MFN where vNVDIMM is going to be.
xen toolstack (1) gets it SPA ranges via dom0 kernel interface (e.g. sysfs and ioctl FIEMAP), and (2) calls a hypercall to map above SPA ranges to the given guest MFN of the given domain.2. Or, given the same inputs, we may combine above two steps into a new dom0 system call that (1) gets the SPA ranges, (2) calls xen hypercall to map SPA ranges, and, one step further, (3) returns SPA ranges to userspace (because QEMU needs these addresses to build ACPI).
Quoted 4 lines
The first way does not need to modify dom0 linux kernel, while the second requires a new system call. I'm not sure whether xen toolstack as a userspace program is considered to be safe to pass the host physical address to hypervisor. If not, maybe the second one is better?
Well, the toolstack does it already. (for MMIO ranges of PCIe devices and such).
I would prefer 1) as it means less kernel code.
Quoted 3 lines
Thanks,
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 23 lines
Quoted 1 line
Quoted 1 line · On 16.03.16 at 13:55, <[email protected]> wrote:
Hi Jan and Konrad,
Quoted 6 lines · Haozhong Zhang
Suddenly realize it's unnecessary to let QEMU get SPA ranges of NVDIMM or files on NVDIMM. We can move that work to toolstack and pass SPA ranges got by toolstack to qemu. In this way, no privileged operations (mmap/mlock/...) are needed in QEMU and non-root QEMU should be able to work even with vNVDIMM hotplug in future.
As I'm going to let toolstack to get NVDIMM SPA ranges. This can be done via dom0 kernel interface and xen hypercalls, and can be implemented in different ways. I'm wondering which of the following ones is preferred by xen.
1. Given
* a file descriptor of either a NVDIMM device or a file on NVDIMM, and
* domain id and guest MFN where vNVDIMM is going to be.
xen toolstack (1) gets it SPA ranges via dom0 kernel interface (e.g. sysfs and ioctl FIEMAP), and (2) calls a hypercall to map above SPA ranges to the given guest MFN of the given domain.
Quoted 4 lines
2. Or, given the same inputs, we may combine above two steps into a new dom0 system call that (1) gets the SPA ranges, (2) calls xen hypercall to map SPA ranges, and, one step further, (3) returns SPA ranges to userspace (because QEMU needs these addresses to build ACPI).
DYM GPA here? Qemu should hardly have a need for SPA when wanting to build ACPI tables for the guest.
Quoted 4 lines
The first way does not need to modify dom0 linux kernel, while the second requires a new system call. I'm not sure whether xen toolstack as a userspace program is considered to be safe to pass the host physical address to hypervisor. If not, maybe the second one is better?
As long as the passing of physical addresses follows to model of MMIO for passed through PCI devices, I don't think there's problem with the tool stack bypassing the Dom0 kernel. So it really all depends on how you make sure that the guest won't get to see memory it has no permission to access.
Which reminds me: When considering a file on NVDIMM, how are you making sure the mapping of the file to disk (i.e. memory) blocks doesn't change while the guest has access to it, e.g. due to some defragmentation going on? And talking of fragmentation - how do you mean to track guest permissions for an unbounded number of address ranges?
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 23 lines · Jan Beulich
Quoted 23 lines
Quoted 1 line
Quoted 1 line · On 16.03.16 at 13:55, <[email protected]> wrote:
Hi Jan and Konrad,
Quoted 6 lines · Haozhong Zhang
Suddenly realize it's unnecessary to let QEMU get SPA ranges of NVDIMM or files on NVDIMM. We can move that work to toolstack and pass SPA ranges got by toolstack to qemu. In this way, no privileged operations (mmap/mlock/...) are needed in QEMU and non-root QEMU should be able to work even with vNVDIMM hotplug in future.
As I'm going to let toolstack to get NVDIMM SPA ranges. This can be done via dom0 kernel interface and xen hypercalls, and can be implemented in different ways. I'm wondering which of the following ones is preferred by xen.
1. Given
* a file descriptor of either a NVDIMM device or a file on NVDIMM, and
* domain id and guest MFN where vNVDIMM is going to be.
xen toolstack (1) gets it SPA ranges via dom0 kernel interface (e.g. sysfs and ioctl FIEMAP), and (2) calls a hypercall to map above SPA ranges to the given guest MFN of the given domain.
Quoted 8 lines
Quoted 4 lines
2. Or, given the same inputs, we may combine above two steps into a new dom0 system call that (1) gets the SPA ranges, (2) calls xen hypercall to map SPA ranges, and, one step further, (3) returns SPA ranges to userspace (because QEMU needs these addresses to build ACPI).
DYM GPA here? Qemu should hardly have a need for SPA when wanting to build ACPI tables for the guest.
Oh, it should be GPA for QEMU and (3) is not needed.
Quoted 11 lines
Quoted 4 lines
The first way does not need to modify dom0 linux kernel, while the second requires a new system call. I'm not sure whether xen toolstack as a userspace program is considered to be safe to pass the host physical address to hypervisor. If not, maybe the second one is better?
As long as the passing of physical addresses follows to model of MMIO for passed through PCI devices, I don't think there's problem with the tool stack bypassing the Dom0 kernel. So it really all depends on how you make sure that the guest won't get to see memory it has no permission to access.
So the toolstack should first use XEN_DOMCTL_iomem_permission to grant permissions to the guest and then call XEN_DOMCTL_memory_mapping for the mapping.
Quoted 4 lines
Which reminds me: When considering a file on NVDIMM, how are you making sure the mapping of the file to disk (i.e. memory) blocks doesn't change while the guest has access to it, e.g. due to some defragmentation going on?
The current linux kernel 4.5 has an experimental "raw device dax support" (enabled by removing "depends on BROKEN" from "config BLK_DEV_DAX") which can guarantee the consistent mapping. The driver developers are going to make it non-broken in linux kernel 4.6.
Quoted 4 lines
And
talking of fragmentation - how do you mean to track guest permissions for an unbounded number of address ranges?
In this case range structs in iomem_caps for NVDIMMs may consume a lot of memory, so I think they are another candidate that should be put in the reserved area on NVDIMM. If we only allow to grant access permissions to NVDIMM page by page (rather than byte), the number of range structs for each NVDIMM in the worst case is still decidable.
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 11 lines
Quoted 1 line
Quoted 1 line · On 16.03.16 at 14:55, <[email protected]> wrote:
Quoted 4 lines · Jan Beulich
Which reminds me: When considering a file on NVDIMM, how are you making sure the mapping of the file to disk (i.e. memory) blocks doesn't change while the guest has access to it, e.g. due to some defragmentation going on?
The current linux kernel 4.5 has an experimental "raw device dax support" (enabled by removing "depends on BROKEN" from "config
BLK_DEV_DAX") which can guarantee the consistent mapping. The driver developers are going to make it non-broken in linux kernel 4.6.
But there you talk about full devices, whereas my question was for files.
Quoted 10 lines
Quoted 4 lines
And
talking of fragmentation - how do you mean to track guest permissions for an unbounded number of address ranges?In this case range structs in
iomem_capsfor NVDIMMs may consume a lot of memory, so I think they are another candidate that should be put in the reserved area on NVDIMM. If we only allow to grant access permissions to NVDIMM page by page (rather than byte), the number of range structs for each NVDIMM in the worst case is still decidable.
Of course the permission granularity is going to by pages, not bytes (or else we couldn't allow the pages to be mapped into guest address space). And the limit on the per-domain range sets isn't going to be allowed to be bumped significantly, at least not for any of the existing ones (or else you'd have to prove such bumping can't be abused). Putting such control structures on NVDIMM is a nice idea, but following our isolation model for normal memory, any such memory used by Xen would then need to be (made) inaccessible to Dom0.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 7 lines · Jan Beulich
Quoted 7 lines
Quoted 1 line
Quoted 1 line · On 16.03.16 at 14:55, <[email protected]> wrote:
Quoted 4 lines · Jan Beulich
Which reminds me: When considering a file on NVDIMM, how are you making sure the mapping of the file to disk (i.e. memory) blocks doesn't change while the guest has access to it, e.g. due to some defragmentation going on?
Quoted 8 lines
Quoted 4 lines
The current linux kernel 4.5 has an experimental "raw device dax support" (enabled by removing "depends on BROKEN" from "config
BLK_DEV_DAX") which can guarantee the consistent mapping. The driver developers are going to make it non-broken in linux kernel 4.6.But there you talk about full devices, whereas my question was for files.
the raw device dax support is for files on NVDIMM.
Quoted 11 lines
Quoted 10 lines
Quoted 4 lines
And
talking of fragmentation - how do you mean to track guest permissions for an unbounded number of address ranges?In this case range structs in
iomem_capsfor NVDIMMs may consume a lot of memory, so I think they are another candidate that should be put in the reserved area on NVDIMM. If we only allow to grant access permissions to NVDIMM page by page (rather than byte), the number of range structs for each NVDIMM in the worst case is still decidable.
Quoted 6 lines
Of course the permission granularity is going to by pages, not bytes (or else we couldn't allow the pages to be mapped into guest address space). And the limit on the per-domain range sets isn't going to be allowed to be bumped significantly, at least not for any of the existing ones (or else you'd have to prove such bumping can't be abused).
What is that limit? the total number of range structs in per-domain range sets? I must miss something when looking through 'case XEN_DOMCTL_iomem_permission' of do_domctl() and didn't find that limit, unless it means alloc_range() will fail when there are lots of range structs.
Quoted 5 lines
Putting such control
structures on NVDIMM is a nice idea, but following our isolation model for normal memory, any such memory used by Xen would then need to be (made) inaccessible to Dom0.
I'm not clear how this is done. By marking those inaccessible pages as unpresent in dom0's page table? Or any example I can follow?
Thanks,
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 14 lines
Quoted 1 line
Quoted 1 line · On 16.03.16 at 15:55, <[email protected]> wrote:
Quoted 12 lines · Jan Beulich
Quoted 11 lines
Quoted 1 line
Quoted 1 line · On 16.03.16 at 14:55, <[email protected]> wrote:
Quoted 4 lines · Jan Beulich
Which reminds me: When considering a file on NVDIMM, how are you making sure the mapping of the file to disk (i.e. memory) blocks doesn't change while the guest has access to it, e.g. due to some defragmentation going on?
The current linux kernel 4.5 has an experimental "raw device dax support" (enabled by removing "depends on BROKEN" from "config
BLK_DEV_DAX") which can guarantee the consistent mapping. The driver developers are going to make it non-broken in linux kernel 4.6.
Quoted 5 lines
Quoted 3 lines
But there you talk about full devices, whereas my question was for files.
the raw device dax support is for files on NVDIMM.
Okay, I can only trust you here. I thought FS_DAX is the file level thing.
Quoted 18 lines
Quoted 11 lines
Quoted 10 lines
Quoted 4 lines
And
talking of fragmentation - how do you mean to track guest permissions for an unbounded number of address ranges?In this case range structs in
iomem_capsfor NVDIMMs may consume a lot of memory, so I think they are another candidate that should be put in the reserved area on NVDIMM. If we only allow to grant access permissions to NVDIMM page by page (rather than byte), the number of range structs for each NVDIMM in the worst case is still decidable.Quoted 6 lines
Of course the permission granularity is going to by pages, not bytes (or else we couldn't allow the pages to be mapped into guest address space). And the limit on the per-domain range sets isn't going to be allowed to be bumped significantly, at least not for any of the existing ones (or else you'd have to prove such bumping can't be abused).
Quoted 5 lines
What is that limit? the total number of range structs in per-domain range sets? I must miss something when looking through 'case
XEN_DOMCTL_iomem_permission' ofdo_domctl()and didn't find that limit, unless it meansalloc_range()will fail when there are lots of range structs.
Oh, I'm sorry, that was a different set of range sets I was thinking about. But note that excessive creation of ranges through XEN_DOMCTL_iomem_permission is not a security issue just because of XSA-77, i.e. we'd still not knowingly allow a severe increase here.
Quoted 7 lines
Quoted 4 lines
Putting such control
structures on NVDIMM is a nice idea, but following our isolation model for normal memory, any such memory used by Xen would then need to be (made) inaccessible to Dom0.I'm not clear how this is done. By marking those inaccessible pages as unpresent in dom0's page table? Or any example I can follow?
That's the problem - so far we had no need to do so since Dom0 was only ever allowed access to memory Xen didn't use for itself or knows it wants to share. Whereas now you want such a resource controlled first by Dom0, and only then handed to Xen. So yes, Dom0 would need to zap any mappings of these pages (and Xen would need to verify that, which would come mostly without new code as long as struct page_info gets properly used for all this memory) before Xen could use it. Much like ballooning out a normal RAM page.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 47 lines · Jan Beulich
Quoted 14 lines
Quoted 1 line
Quoted 1 line · On 16.03.16 at 15:55, <[email protected]> wrote:
Quoted 12 lines · Jan Beulich
Quoted 11 lines
Quoted 1 line
Quoted 1 line · On 16.03.16 at 14:55, <[email protected]> wrote:
Quoted 4 lines · Jan Beulich
Which reminds me: When considering a file on NVDIMM, how are you making sure the mapping of the file to disk (i.e. memory) blocks doesn't change while the guest has access to it, e.g. due to some defragmentation going on?
The current linux kernel 4.5 has an experimental "raw device dax support" (enabled by removing "depends on BROKEN" from "config
BLK_DEV_DAX") which can guarantee the consistent mapping. The driver developers are going to make it non-broken in linux kernel 4.6.Quoted 5 lines
Quoted 3 lines
But there you talk about full devices, whereas my question was for files.
the raw device dax support is for files on NVDIMM.
Okay, I can only trust you here. I thought
FS_DAXis the file level thing.Quoted 18 lines
Quoted 11 lines
Quoted 10 lines
Quoted 4 lines
And
talking of fragmentation - how do you mean to track guest permissions for an unbounded number of address ranges?In this case range structs in
iomem_capsfor NVDIMMs may consume a lot of memory, so I think they are another candidate that should be put in the reserved area on NVDIMM. If we only allow to grant access permissions to NVDIMM page by page (rather than byte), the number of range structs for each NVDIMM in the worst case is still decidable.Quoted 6 lines
Of course the permission granularity is going to by pages, not bytes (or else we couldn't allow the pages to be mapped into guest address space). And the limit on the per-domain range sets isn't going to be allowed to be bumped significantly, at least not for any of the existing ones (or else you'd have to prove such bumping can't be abused).
Quoted 5 lines
What is that limit? the total number of range structs in per-domain range sets? I must miss something when looking through 'case
XEN_DOMCTL_iomem_permission' ofdo_domctl()and didn't find that limit, unless it meansalloc_range()will fail when there are lots of range structs.
Quoted 6 lines
Oh, I'm sorry, that was a different set of range sets I was thinking about. But note that excessive creation of ranges through
XEN_DOMCTL_iomem_permissionis not a security issue just because of XSA-77, i.e. we'd still not knowingly allow a severe increase here.
I didn't notice that multiple domains can all have access permission to an iomem range, i.e. there can be multiple range structs for a single iomem range. If range structs for NVDIMM are put on NVDIMM, then there would be still a huge amount of them on NVDIMM in the worst case (maximum number of domains * number of NVDIMM pages).
A workaround is to only allow a range of NVDIMM pages be accessed by a single domain. Whenever we add the access permission of NVDIMM pages to a domain, we also remove the permission from its current grantee. In this way, we only need to put 'number of NVDIMM pages' range structs on NVDIMM in the worst case.
Quoted 8 lines
Quoted 7 lines
Quoted 4 lines
Putting such control
structures on NVDIMM is a nice idea, but following our isolation model for normal memory, any such memory used by Xen would then need to be (made) inaccessible to Dom0.I'm not clear how this is done. By marking those inaccessible pages as unpresent in dom0's page table? Or any example I can follow?
Quoted 10 lines
That's the problem - so far we had no need to do so since Dom0 was only ever allowed access to memory Xen didn't use for itself or knows it wants to share. Whereas now you want such a resource controlled first by Dom0, and only then handed to Xen. So yes, Dom0 would need to zap any mappings of these pages (and Xen would need to verify that, which would come mostly without new code as long as struct
page_infogets properly used for all this memory) before Xen could use it. Much like ballooning out a normal RAM page.
Thanks, I'll look into this balloon approach.
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 43 lines
Quoted 1 line
Quoted 1 line · On 17.03.16 at 09:58, <[email protected]> wrote:
Quoted 28 lines · Jan Beulich
Quoted 22 lines
Quoted 1 line
Quoted 1 line · On 16.03.16 at 15:55, <[email protected]> wrote:
Quoted 13 lines · Jan Beulich
Quoted 7 lines
Quoted 1 line
Quoted 1 line · On 16.03.16 at 14:55, <[email protected]> wrote:
Quoted 4 lines · Jan Beulich
And
talking of fragmentation - how do you mean to track guest permissions for an unbounded number of address ranges?Quoted 5 lines
In this case range structs in
iomem_capsfor NVDIMMs may consume a lot of memory, so I think they are another candidate that should be put in the reserved area on NVDIMM. If we only allow to grant access permissions to NVDIMM page by page (rather than byte), the number of range structs for each NVDIMM in the worst case is still decidable.Quoted 6 lines
Of course the permission granularity is going to by pages, not bytes (or else we couldn't allow the pages to be mapped into guest address space). And the limit on the per-domain range sets isn't going to be allowed to be bumped significantly, at least not for any of the existing ones (or else you'd have to prove such bumping can't be abused).
Quoted 5 lines
What is that limit? the total number of range structs in per-domain range sets? I must miss something when looking through 'case
XEN_DOMCTL_iomem_permission' ofdo_domctl()and didn't find that limit, unless it meansalloc_range()will fail when there are lots of range structs.Quoted 6 lines
Oh, I'm sorry, that was a different set of range sets I was thinking about. But note that excessive creation of ranges through
XEN_DOMCTL_iomem_permissionis not a security issue just because of XSA-77, i.e. we'd still not knowingly allow a severe increase here.I didn't notice that multiple domains can all have access permission to an iomem range, i.e. there can be multiple range structs for a single iomem range. If range structs for NVDIMM are put on NVDIMM, then there would be still a huge amount of them on NVDIMM in the worst case (maximum number of domains * number of NVDIMM pages).
Quoted 5 lines
A workaround is to only allow a range of NVDIMM pages be accessed by a single domain. Whenever we add the access permission of NVDIMM pages to a domain, we also remove the permission from its current grantee. In this way, we only need to put 'number of NVDIMM pages' range structs on NVDIMM in the worst case.
But will this work? There's a reason multiple domains are permitted
access: The domain running qemu for the guest, for example, needs to be able to access guest memory.
No matter how much you and others are opposed to this, I can't help myself thinking that PMEM regions should be treated like RAM (and hence be under full control of Xen), whereas PBLK regions could indeed be treated like MMIO (and hence partly be under the control of Dom0).
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 49 lines · Jan Beulich
Quoted 43 lines
Quoted 1 line
Quoted 1 line · On 17.03.16 at 09:58, <[email protected]> wrote:
Quoted 28 lines · Jan Beulich
Quoted 22 lines
Quoted 1 line
Quoted 1 line · On 16.03.16 at 15:55, <[email protected]> wrote:
Quoted 13 lines · Jan Beulich
Quoted 7 lines
Quoted 1 line
Quoted 1 line · On 16.03.16 at 14:55, <[email protected]> wrote:
Quoted 4 lines · Jan Beulich
And
talking of fragmentation - how do you mean to track guest permissions for an unbounded number of address ranges?Quoted 5 lines
In this case range structs in
iomem_capsfor NVDIMMs may consume a lot of memory, so I think they are another candidate that should be put in the reserved area on NVDIMM. If we only allow to grant access permissions to NVDIMM page by page (rather than byte), the number of range structs for each NVDIMM in the worst case is still decidable.Quoted 6 lines
Of course the permission granularity is going to by pages, not bytes (or else we couldn't allow the pages to be mapped into guest address space). And the limit on the per-domain range sets isn't going to be allowed to be bumped significantly, at least not for any of the existing ones (or else you'd have to prove such bumping can't be abused).
Quoted 5 lines
What is that limit? the total number of range structs in per-domain range sets? I must miss something when looking through 'case
XEN_DOMCTL_iomem_permission' ofdo_domctl()and didn't find that limit, unless it meansalloc_range()will fail when there are lots of range structs.Quoted 6 lines
Oh, I'm sorry, that was a different set of range sets I was thinking about. But note that excessive creation of ranges through
XEN_DOMCTL_iomem_permissionis not a security issue just because of XSA-77, i.e. we'd still not knowingly allow a severe increase here.I didn't notice that multiple domains can all have access permission to an iomem range, i.e. there can be multiple range structs for a single iomem range. If range structs for NVDIMM are put on NVDIMM, then there would be still a huge amount of them on NVDIMM in the worst case (maximum number of domains * number of NVDIMM pages).
Quoted 5 lines
A workaround is to only allow a range of NVDIMM pages be accessed by a single domain. Whenever we add the access permission of NVDIMM pages to a domain, we also remove the permission from its current grantee. In this way, we only need to put 'number of NVDIMM pages' range structs on NVDIMM in the worst case.
Quoted 4 lines
But will this work? There's a reason multiple domains are permitted
access: The domain running qemu for the guest, for example, needs to be able to access guest memory.
QEMU now only maintains ACPI tables and emulates _DSM for vNVDIMM which both do not need to access NVDIMM pages mapped to guest.
Quoted 6 lines
No matter how much you and others are opposed to this, I can't help myself thinking that PMEM regions should be treated like RAM (and hence be under full control of Xen), whereas PBLK regions could indeed be treated like MMIO (and hence partly be under the control of Dom0).
Hmm, making Xen has full control could at least make reserving space on NVDIMM easier. I guess full control does not include manipulating file systems on NVDIMM which can be still left to dom0?
Then there is another problem (which also exists in the current design): does Xen need to emulate NVDIMM _DSM for dom0? Take the _DSM that access label storage area (for namespace) for example:
The way Linux reserving space on pmem mode NVDIMM is to leave the reserved space at the beginning of pmem mode NVDIMM and create a pmem namespace which starts from the end of the reserved space. Because the reservation information is written in the namespace in the NVDIMM label storage area, every OS that follows the namespace spec would not mistakenly write files in the reserved area. I prefer to the same way if Xen is going to do the reservation. We definitely don't want dom0 to break the label storage area, so Xen seemingly needs to emulate the corresponding _DSM functions for dom0? If so, which part, the hypervisor or the toolstack, should do the emulation?
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 51 lines
Quoted 1 line
Quoted 1 line · On 17.03.16 at 13:44, <[email protected]> wrote:
Quoted 49 lines · Jan Beulich
Quoted 48 lines
Quoted 1 line
Quoted 1 line · On 17.03.16 at 09:58, <[email protected]> wrote:
Quoted 28 lines · Jan Beulich
Quoted 22 lines
Quoted 1 line
Quoted 1 line · On 16.03.16 at 15:55, <[email protected]> wrote:
Quoted 13 lines · Jan Beulich
Quoted 7 lines
Quoted 1 line
Quoted 1 line · On 16.03.16 at 14:55, <[email protected]> wrote:
Quoted 4 lines · Jan Beulich
And
talking of fragmentation - how do you mean to track guest permissions for an unbounded number of address ranges?Quoted 5 lines
In this case range structs in
iomem_capsfor NVDIMMs may consume a lot of memory, so I think they are another candidate that should be put in the reserved area on NVDIMM. If we only allow to grant access permissions to NVDIMM page by page (rather than byte), the number of range structs for each NVDIMM in the worst case is still decidable.Quoted 6 lines
Of course the permission granularity is going to by pages, not bytes (or else we couldn't allow the pages to be mapped into guest address space). And the limit on the per-domain range sets isn't going to be allowed to be bumped significantly, at least not for any of the existing ones (or else you'd have to prove such bumping can't be abused).
Quoted 5 lines
What is that limit? the total number of range structs in per-domain range sets? I must miss something when looking through 'case
XEN_DOMCTL_iomem_permission' ofdo_domctl()and didn't find that limit, unless it meansalloc_range()will fail when there are lots of range structs.Quoted 6 lines
Oh, I'm sorry, that was a different set of range sets I was thinking about. But note that excessive creation of ranges through
XEN_DOMCTL_iomem_permissionis not a security issue just because of XSA-77, i.e. we'd still not knowingly allow a severe increase here.I didn't notice that multiple domains can all have access permission to an iomem range, i.e. there can be multiple range structs for a single iomem range. If range structs for NVDIMM are put on NVDIMM, then there would be still a huge amount of them on NVDIMM in the worst case (maximum number of domains * number of NVDIMM pages).
A workaround is to only allow a range of NVDIMM pages be accessed by a single domain. Whenever we add the access permission of NVDIMM pages to a domain, we also remove the permission from its current grantee. In this way, we only need to put 'number of NVDIMM pages' range structs on NVDIMM in the worst case.
Quoted 7 lines
Quoted 4 lines
But will this work? There's a reason multiple domains are permitted
access: The domain running qemu for the guest, for example, needs to be able to access guest memory.QEMU now only maintains ACPI tables and emulates
_DSMfor vNVDIMM which both do not need to access NVDIMM pages mapped to guest.
For one - this was only an example. And then - iirc qemu keeps mappings of certain guest RAM ranges. If I'm remembering this right, then why would it be excluded that it also may need mappings of guest NVDIMM?
Quoted 15 lines
Quoted 6 lines
No matter how much you and others are opposed to this, I can't help myself thinking that PMEM regions should be treated like RAM (and hence be under full control of Xen), whereas PBLK regions could indeed be treated like MMIO (and hence partly be under the control of Dom0).
Hmm, making Xen has full control could at least make reserving space on NVDIMM easier. I guess full control does not include manipulating file systems on NVDIMM which can be still left to dom0?
Then there is another problem (which also exists in the current design): does Xen need to emulate NVDIMM
_DSMfor dom0? Take the_DSMthat access label storage area (for namespace) for example:
Quoted 10 lines
The way Linux reserving space on pmem mode NVDIMM is to leave the reserved space at the beginning of pmem mode NVDIMM and create a pmem namespace which starts from the end of the reserved space. Because the reservation information is written in the namespace in the NVDIMM label storage area, every OS that follows the namespace spec would not mistakenly write files in the reserved area. I prefer to the same way if Xen is going to do the reservation. We definitely don't want dom0 to break the label storage area, so Xen seemingly needs to emulate the corresponding
_DSMfunctions for dom0? If so, which part, the hypervisor or the toolstack, should do the emulation?
I don't think I can answer all but the very last point: Of course this can't be done in the tool stack, since afaict the Dom0 kernel will want to evaluate _DSM before the tool stack even runs.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 56 lines · Jan Beulich
Quoted 56 lines
Quoted 1 line
Quoted 1 line · On 17.03.16 at 13:44, <[email protected]> wrote:
Quoted 53 lines · Jan Beulich
Quoted 43 lines
Quoted 1 line
Quoted 1 line · On 17.03.16 at 09:58, <[email protected]> wrote:
Quoted 28 lines · Jan Beulich
Quoted 22 lines
Quoted 1 line
Quoted 1 line · On 16.03.16 at 15:55, <[email protected]> wrote:
Quoted 13 lines · Jan Beulich
Quoted 7 lines
Quoted 1 line
Quoted 1 line · On 16.03.16 at 14:55, <[email protected]> wrote:
Quoted 4 lines · Jan Beulich
And
talking of fragmentation - how do you mean to track guest permissions for an unbounded number of address ranges?Quoted 5 lines
In this case range structs in
iomem_capsfor NVDIMMs may consume a lot of memory, so I think they are another candidate that should be put in the reserved area on NVDIMM. If we only allow to grant access permissions to NVDIMM page by page (rather than byte), the number of range structs for each NVDIMM in the worst case is still decidable.Quoted 6 lines
Of course the permission granularity is going to by pages, not bytes (or else we couldn't allow the pages to be mapped into guest address space). And the limit on the per-domain range sets isn't going to be allowed to be bumped significantly, at least not for any of the existing ones (or else you'd have to prove such bumping can't be abused).
Quoted 5 lines
What is that limit? the total number of range structs in per-domain range sets? I must miss something when looking through 'case
XEN_DOMCTL_iomem_permission' ofdo_domctl()and didn't find that limit, unless it meansalloc_range()will fail when there are lots of range structs.Quoted 6 lines
Oh, I'm sorry, that was a different set of range sets I was thinking about. But note that excessive creation of ranges through
XEN_DOMCTL_iomem_permissionis not a security issue just because of XSA-77, i.e. we'd still not knowingly allow a severe increase here.I didn't notice that multiple domains can all have access permission to an iomem range, i.e. there can be multiple range structs for a single iomem range. If range structs for NVDIMM are put on NVDIMM, then there would be still a huge amount of them on NVDIMM in the worst case (maximum number of domains * number of NVDIMM pages).
Quoted 5 lines
A workaround is to only allow a range of NVDIMM pages be accessed by a single domain. Whenever we add the access permission of NVDIMM pages to a domain, we also remove the permission from its current grantee. In this way, we only need to put 'number of NVDIMM pages' range structs on NVDIMM in the worst case.
But will this work? There's a reason multiple domains are permitted
access: The domain running qemu for the guest, for example, needs to be able to access guest memory.
Quoted 8 lines
Quoted 2 lines
QEMU now only maintains ACPI tables and emulates
_DSMfor vNVDIMM which both do not need to access NVDIMM pages mapped to guest.For one - this was only an example. And then - iirc qemu keeps mappings of certain guest RAM ranges. If I'm remembering this right, then why would it be excluded that it also may need mappings of guest NVDIMM?
QEMU keeps mappings of guest memory because (1) that mapping is created by itself, and/or (2) certain device emulation needs to access the guest memory. But for vNVDIMM, I'm going to move the creation of its mappings out of qemu to toolstack and vNVDIMM in QEMU does not access vNVDIMM pages mapped to guest, so it's not necessary to let qemu keeps vNVDIMM mappings.
Quoted 26 lines
Quoted 15 lines
Quoted 6 lines
No matter how much you and others are opposed to this, I can't help myself thinking that PMEM regions should be treated like RAM (and hence be under full control of Xen), whereas PBLK regions could indeed be treated like MMIO (and hence partly be under the control of Dom0).
Hmm, making Xen has full control could at least make reserving space on NVDIMM easier. I guess full control does not include manipulating file systems on NVDIMM which can be still left to dom0?
Then there is another problem (which also exists in the current design): does Xen need to emulate NVDIMM
_DSMfor dom0? Take the_DSMthat access label storage area (for namespace) for example:Quoted 10 lines
The way Linux reserving space on pmem mode NVDIMM is to leave the reserved space at the beginning of pmem mode NVDIMM and create a pmem namespace which starts from the end of the reserved space. Because the reservation information is written in the namespace in the NVDIMM label storage area, every OS that follows the namespace spec would not mistakenly write files in the reserved area. I prefer to the same way if Xen is going to do the reservation. We definitely don't want dom0 to break the label storage area, so Xen seemingly needs to emulate the corresponding
_DSMfunctions for dom0? If so, which part, the hypervisor or the toolstack, should do the emulation?
Quoted 4 lines
I don't think I can answer all but the very last point: Of course this can't be done in the tool stack, since afaict the Dom0 kernel will want to evaluate
_DSMbefore the tool stack even runs.
Or, we could modify dom0 kernel to just use the label storage area as is and does not modify it. Can xen hypervisor trust dom0 kernel in this aspect?
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 22 lines
Quoted 1 line
Quoted 1 line · On 17.03.16 at 14:29, <[email protected]> wrote:
Quoted 20 lines · Jan Beulich
Quoted 19 lines
Quoted 1 line
Quoted 1 line · On 17.03.16 at 13:44, <[email protected]> wrote:
Hmm, making Xen has full control could at least make reserving space on NVDIMM easier. I guess full control does not include manipulating file systems on NVDIMM which can be still left to dom0?
Then there is another problem (which also exists in the current design): does Xen need to emulate NVDIMM
_DSMfor dom0? Take the_DSMthat access label storage area (for namespace) for example:The way Linux reserving space on pmem mode NVDIMM is to leave the reserved space at the beginning of pmem mode NVDIMM and create a pmem namespace which starts from the end of the reserved space. Because the reservation information is written in the namespace in the NVDIMM label storage area, every OS that follows the namespace spec would not mistakenly write files in the reserved area. I prefer to the same way if Xen is going to do the reservation. We definitely don't want dom0 to break the label storage area, so Xen seemingly needs to emulate the corresponding
_DSMfunctions for dom0? If so, which part, the hypervisor or the toolstack, should do the emulation?
Quoted 6 lines
Quoted 3 lines
I don't think I can answer all but the very last point: Of course this can't be done in the tool stack, since afaict the Dom0 kernel will want to evaluate
_DSMbefore the tool stack even runs.Or, we could modify dom0 kernel to just use the label storage area as is and does not modify it. Can xen hypervisor trust dom0 kernel in this aspect?
I think so, yes.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Haozhong Zhang writes ("Re: [Xen-devel] [RFC Design Doc] Add vNVDIMM support for Xen"):
Quoted 6 lines
QEMU keeps mappings of guest memory because (1) that mapping is created by itself, and/or (2) certain device emulation needs to access the guest memory. But for vNVDIMM, I'm going to move the creation of its mappings out of qemu to toolstack and vNVDIMM in QEMU does not access vNVDIMM pages mapped to guest, so it's not necessary to let qemu keeps vNVDIMM mappings.
I'm confused by this.
Suppose a guest uses an emulated device (or backend) provided by qemu, to do DMA to an vNVDIMM. Then qemu will need to map the real NVDIMM pages into its own address space, so that it can write to the memory (ie, do the virtual DMA).
That virtual DMA might well involve a direct mapping in the kernel underlying qemu: ie, qemu might use O_DIRECT to have its kernel write directly to the NVDIMM, and with luck the actual device backing the virtual device will be able to DMA to the NVDIMM.
All of this seems to me to mean that qemu needs to be able to map its guest's parts of NVDIMMs
There are probably other example: memory inspection systems used by virus scanners etc.; debuggers used to inspect a guest from outside; etc.
I haven't even got started on save/restore...
Ian.
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 20 lines · Ian Jackson
Haozhong Zhang writes ("Re: [Xen-devel] [RFC Design Doc] Add vNVDIMM support for Xen"):
Quoted 6 lines
QEMU keeps mappings of guest memory because (1) that mapping is created by itself, and/or (2) certain device emulation needs to access the guest memory. But for vNVDIMM, I'm going to move the creation of its mappings out of qemu to toolstack and vNVDIMM in QEMU does not access vNVDIMM pages mapped to guest, so it's not necessary to let qemu keeps vNVDIMM mappings.
I'm confused by this.
Suppose a guest uses an emulated device (or backend) provided by qemu, to do DMA to an vNVDIMM. Then qemu will need to map the real NVDIMM pages into its own address space, so that it can write to the memory (ie, do the virtual DMA).
That virtual DMA might well involve a direct mapping in the kernel underlying qemu: ie, qemu might use
O_DIRECTto have its kernel write directly to the NVDIMM, and with luck the actual device backing the virtual device will be able to DMA to the NVDIMM.
Quoted 9 lines
All of this seems to me to mean that qemu needs to be able to map its guest's parts of NVDIMMs
There are probably other example: memory inspection systems used by virus scanners etc.; debuggers used to inspect a guest from outside; etc.
I haven't even got started on save/restore...
Oops, so many cases I missed. Thanks Ian for pointing out all these! Now I need to reconsider how to manage guest permissions for NVDIMM pages.
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 28 lines · Haozhong Zhang
Quoted 27 lines · Ian Jackson
Haozhong Zhang writes ("Re: [Xen-devel] [RFC Design Doc] Add vNVDIMM support for Xen"):
Quoted 6 lines
QEMU keeps mappings of guest memory because (1) that mapping is created by itself, and/or (2) certain device emulation needs to access the guest memory. But for vNVDIMM, I'm going to move the creation of its mappings out of qemu to toolstack and vNVDIMM in QEMU does not access vNVDIMM pages mapped to guest, so it's not necessary to let qemu keeps vNVDIMM mappings.
I'm confused by this.
Suppose a guest uses an emulated device (or backend) provided by qemu, to do DMA to an vNVDIMM. Then qemu will need to map the real NVDIMM pages into its own address space, so that it can write to the memory (ie, do the virtual DMA).
That virtual DMA might well involve a direct mapping in the kernel underlying qemu: ie, qemu might use
O_DIRECTto have its kernel write directly to the NVDIMM, and with luck the actual device backing the virtual device will be able to DMA to the NVDIMM.All of this seems to me to mean that qemu needs to be able to map its guest's parts of NVDIMMs
There are probably other example: memory inspection systems used by virus scanners etc.; debuggers used to inspect a guest from outside; etc.
Quoted 6 lines
Quoted 2 lines
I haven't even got started on save/restore...
Oops, so many cases I missed. Thanks Ian for pointing out all these! Now I need to reconsider how to manage guest permissions for NVDIMM pages.
I still cannot find a neat approach to manage guest permissions for nvdimm pages. A possible one is to use a per-domain bitmap to track
permissions: each bit corresponding to an nvdimm page. The bitmap can save lots of spaces and even be stored in the normal ram, but operating it for a large nvdimm range, especially for a contiguous one, is slower than rangeset.
BTW, if I take the other way to map nvdimm pages to guest
(http://lists.xenproject.org/archives/html/xen-devel/2016-03/msg01972.html)
| 2. Or, given the same inputs, we may combine above two steps into a new | dom0 system call that (1) gets the SPA ranges, (2) calls xen | hypercall to map SPA ranges
and treat nvdimm as normal ram, then xen will not need to use rangeset or above bitmap to track guest permissions for nvdimm? But looking at how qemu currently populates guest memory via XENMEM_populate_physmap , and other hypercalls like XENMEM_[in|de]crease_reservation, it looks like that mapping a _dedicated_ piece of host ram to guest is not allowed out of the hypervisor (and not allowed even in dom0 kernel)? Is it for security concerns, e.g. avoiding a malfunctioned dom0 leaking guest memory?
Thanks,
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 37 lines
Quoted 1 line
Quoted 1 line · On 29.03.16 at 10:47, <[email protected]> wrote:
Quoted 28 lines · Haozhong Zhang
Quoted 27 lines · Ian Jackson
Haozhong Zhang writes ("Re: [Xen-devel] [RFC Design Doc] Add vNVDIMM support for Xen"):
Quoted 6 lines
QEMU keeps mappings of guest memory because (1) that mapping is created by itself, and/or (2) certain device emulation needs to access the guest memory. But for vNVDIMM, I'm going to move the creation of its mappings out of qemu to toolstack and vNVDIMM in QEMU does not access vNVDIMM pages mapped to guest, so it's not necessary to let qemu keeps vNVDIMM mappings.
I'm confused by this.
Suppose a guest uses an emulated device (or backend) provided by qemu, to do DMA to an vNVDIMM. Then qemu will need to map the real NVDIMM pages into its own address space, so that it can write to the memory (ie, do the virtual DMA).
That virtual DMA might well involve a direct mapping in the kernel underlying qemu: ie, qemu might use
O_DIRECTto have its kernel write directly to the NVDIMM, and with luck the actual device backing the virtual device will be able to DMA to the NVDIMM.All of this seems to me to mean that qemu needs to be able to map its guest's parts of NVDIMMs
There are probably other example: memory inspection systems used by virus scanners etc.; debuggers used to inspect a guest from outside; etc.
Quoted 6 lines
Quoted 2 lines
I haven't even got started on save/restore...
Oops, so many cases I missed. Thanks Ian for pointing out all these! Now I need to reconsider how to manage guest permissions for NVDIMM pages.
Quoted 6 lines
I still cannot find a neat approach to manage guest permissions for nvdimm pages. A possible one is to use a per-domain bitmap to track
permissions: each bit corresponding to an nvdimm page. The bitmap can save lots of spaces and even be stored in the normal ram, but operating it for a large nvdimm range, especially for a contiguous one, is slower than rangeset.
I don't follow: What would a single bit in that bitmap mean? Any guest may access the page? That surely wouldn't be what we need.
Quoted 5 lines
BTW, if I take the other way to map nvdimm pages to guest
(http://lists.xenproject.org/archives/html/xen-devel/2016-03/msg01972.html)| 2. Or, given the same inputs, we may combine above two steps into a new | dom0 system call that (1) gets the SPA ranges, (2) calls xen | hypercall to map SPA ranges
Quoted 8 lines
and treat nvdimm as normal ram, then xen will not need to use rangeset or above bitmap to track guest permissions for nvdimm? But looking at how qemu currently populates guest memory via
XENMEM_populate_physmap, and other hypercalls like XENMEM_[in|de]crease_reservation, it looks like that mapping a _dedicated_ piece of host ram to guest is not allowed out of the hypervisor (and not allowed even in dom0 kernel)? Is it for security concerns, e.g. avoiding a malfunctioned dom0 leaking guest memory?
Well, it's simply because RAM is a resource managed through allocation/freeing, instead of via reserving chunks for special purposes.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 44 lines · Jan Beulich
Quoted 37 lines
Quoted 1 line
Quoted 1 line · On 29.03.16 at 10:47, <[email protected]> wrote:
Quoted 28 lines · Haozhong Zhang
Quoted 27 lines · Ian Jackson
Haozhong Zhang writes ("Re: [Xen-devel] [RFC Design Doc] Add vNVDIMM support for Xen"):
Quoted 6 lines
QEMU keeps mappings of guest memory because (1) that mapping is created by itself, and/or (2) certain device emulation needs to access the guest memory. But for vNVDIMM, I'm going to move the creation of its mappings out of qemu to toolstack and vNVDIMM in QEMU does not access vNVDIMM pages mapped to guest, so it's not necessary to let qemu keeps vNVDIMM mappings.
I'm confused by this.
Suppose a guest uses an emulated device (or backend) provided by qemu, to do DMA to an vNVDIMM. Then qemu will need to map the real NVDIMM pages into its own address space, so that it can write to the memory (ie, do the virtual DMA).
That virtual DMA might well involve a direct mapping in the kernel underlying qemu: ie, qemu might use
O_DIRECTto have its kernel write directly to the NVDIMM, and with luck the actual device backing the virtual device will be able to DMA to the NVDIMM.All of this seems to me to mean that qemu needs to be able to map its guest's parts of NVDIMMs
There are probably other example: memory inspection systems used by virus scanners etc.; debuggers used to inspect a guest from outside; etc.
Quoted 6 lines
Quoted 2 lines
I haven't even got started on save/restore...
Oops, so many cases I missed. Thanks Ian for pointing out all these! Now I need to reconsider how to manage guest permissions for NVDIMM pages.
Quoted 6 lines
I still cannot find a neat approach to manage guest permissions for nvdimm pages. A possible one is to use a per-domain bitmap to track
permissions: each bit corresponding to an nvdimm page. The bitmap can save lots of spaces and even be stored in the normal ram, but operating it for a large nvdimm range, especially for a contiguous one, is slower than rangeset.
Quoted 4 lines
I don't follow: What would a single bit in that bitmap mean? Any guest may access the page? That surely wouldn't be what we need.
For a host having a N pages of nvdimm, each domain will have a N bits bitmap. If the m'th bit of a domain's bitmap is set, then that domain has the permission to access the m'th host nvdimm page.
Quoted 14 lines
Quoted 5 lines
BTW, if I take the other way to map nvdimm pages to guest
(http://lists.xenproject.org/archives/html/xen-devel/2016-03/msg01972.html)| 2. Or, given the same inputs, we may combine above two steps into a new | dom0 system call that (1) gets the SPA ranges, (2) calls xen | hypercall to map SPA rangesQuoted 8 lines
and treat nvdimm as normal ram, then xen will not need to use rangeset or above bitmap to track guest permissions for nvdimm? But looking at how qemu currently populates guest memory via
XENMEM_populate_physmap, and other hypercalls like XENMEM_[in|de]crease_reservation, it looks like that mapping a _dedicated_ piece of host ram to guest is not allowed out of the hypervisor (and not allowed even in dom0 kernel)? Is it for security concerns, e.g. avoiding a malfunctioned dom0 leaking guest memory?
Quoted 4 lines
Well, it's simply because RAM is a resource managed through allocation/freeing, instead of via reserving chunks for special purposes.
So that means xen can always ensure the ram assigned to a guest is what the guest is permitted to access, so no data structures like iomem_caps is needed for ram. If I have to introduce a hypercall that maps the dedicated host ram/nvdimm to guest, then the explicit permission management is still needed, regardless of who (dom0 kernel, qemu or toolstack) will use it. Right?
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 47 lines
Quoted 1 line
Quoted 1 line · On 29.03.16 at 12:10, <[email protected]> wrote:
Quoted 4 lines · Jan Beulich
Quoted 4 lines
Quoted 1 line
Quoted 1 line · On 29.03.16 at 10:47, <[email protected]> wrote:
Quoted 2 lines · Haozhong Zhang
Quoted 1 line · Ian Jackson
Haozhong Zhang writes ("Re: [Xen-devel] [RFC Design Doc] Add vNVDIMM
support for Xen"):
Quoted 40 lines
Quoted 39 lines
Quoted 26 lines
Quoted 26 lines
Quoted 6 lines
QEMU keeps mappings of guest memory because (1) that mapping is created by itself, and/or (2) certain device emulation needs to access the guest memory. But for vNVDIMM, I'm going to move the creation of its mappings out of qemu to toolstack and vNVDIMM in QEMU does not access vNVDIMM pages mapped to guest, so it's not necessary to let qemu keeps vNVDIMM mappings.
I'm confused by this.
Suppose a guest uses an emulated device (or backend) provided by qemu, to do DMA to an vNVDIMM. Then qemu will need to map the real NVDIMM pages into its own address space, so that it can write to the memory (ie, do the virtual DMA).
That virtual DMA might well involve a direct mapping in the kernel underlying qemu: ie, qemu might use
O_DIRECTto have its kernel write directly to the NVDIMM, and with luck the actual device backing the virtual device will be able to DMA to the NVDIMM.All of this seems to me to mean that qemu needs to be able to map its guest's parts of NVDIMMs
There are probably other example: memory inspection systems used by virus scanners etc.; debuggers used to inspect a guest from outside; etc.
Quoted 6 lines
Quoted 2 lines
I haven't even got started on save/restore...
Oops, so many cases I missed. Thanks Ian for pointing out all these! Now I need to reconsider how to manage guest permissions for NVDIMM pages.
I still cannot find a neat approach to manage guest permissions for nvdimm pages. A possible one is to use a per-domain bitmap to track
permissions: each bit corresponding to an nvdimm page. The bitmap can save lots of spaces and even be stored in the normal ram, but operating it for a large nvdimm range, especially for a contiguous one, is slower than rangeset.
Quoted 8 lines
Quoted 4 lines
I don't follow: What would a single bit in that bitmap mean? Any guest may access the page? That surely wouldn't be what we need.
For a host having a N pages of nvdimm, each domain will have a N bits bitmap. If the m'th bit of a domain's bitmap is set, then that domain has the permission to access the m'th host nvdimm page.
Which will be more overhead as soon as there are enough such domains in a system.
Quoted 19 lines
Quoted 14 lines
Quoted 5 lines
BTW, if I take the other way to map nvdimm pages to guest
(http://lists.xenproject.org/archives/html/xen-devel/2016-03/msg01972.html)| 2. Or, given the same inputs, we may combine above two steps into a new | dom0 system call that (1) gets the SPA ranges, (2) calls xen | hypercall to map SPA rangesQuoted 8 lines
and treat nvdimm as normal ram, then xen will not need to use rangeset or above bitmap to track guest permissions for nvdimm? But looking at how qemu currently populates guest memory via
XENMEM_populate_physmap, and other hypercalls like XENMEM_[in|de]crease_reservation, it looks like that mapping a _dedicated_ piece of host ram to guest is not allowed out of the hypervisor (and not allowed even in dom0 kernel)? Is it for security concerns, e.g. avoiding a malfunctioned dom0 leaking guest memory?Quoted 4 lines
Well, it's simply because RAM is a resource managed through allocation/freeing, instead of via reserving chunks for special purposes.
Quoted 6 lines
So that means xen can always ensure the ram assigned to a guest is what the guest is permitted to access, so no data structures like
iomem_capsis needed for ram. If I have to introduce a hypercall that maps the dedicated host ram/nvdimm to guest, then the explicit permission management is still needed, regardless of who (dom0 kernel, qemu or toolstack) will use it. Right?
Yes (if you really mean to go that route).
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 3 lines · Jan Beulich
Quoted 3 lines
Quoted 1 line
Quoted 1 line · On 29.03.16 at 12:10, <[email protected]> wrote:
Quoted 1 line · Jan Beulich
Quoted 1 line
Quoted 1 line
Quoted 1 line · On 29.03.16 at 10:47, <[email protected]> wrote:
[..]
Quoted 12 lines
Quoted 12 lines
Quoted 11 lines
Quoted 6 lines
I still cannot find a neat approach to manage guest permissions for nvdimm pages. A possible one is to use a per-domain bitmap to track
permissions: each bit corresponding to an nvdimm page. The bitmap can save lots of spaces and even be stored in the normal ram, but operating it for a large nvdimm range, especially for a contiguous one, is slower than rangeset.I don't follow: What would a single bit in that bitmap mean? Any guest may access the page? That surely wouldn't be what we need.
Quoted 7 lines
Quoted 3 lines
For a host having a N pages of nvdimm, each domain will have a N bits bitmap. If the m'th bit of a domain's bitmap is set, then that domain has the permission to access the m'th host nvdimm page.
Which will be more overhead as soon as there are enough such domains in a system.
Sorry for the late reply.
I think we can make some optimization to reduce the space consumed by the bitmap.
A per-domain bitmap covering the entire host NVDIMM address range is wasteful especially if the actual used ranges are congregated. We may take following ways to reduce its space.
1) Split the per-domain bitmap into multiple sub-bitmap and each sub-bitmap covers a smaller and contiguous sub host NVDIMM address range. In the beginning, no sub-bitmap is allocated for the domain. If the access permission to a host NVDIMM page in a sub host address range is added to a domain, only the sub-bitmap for that address range is allocated for the domain. If access permissions to all host NVDIMM pages in a sub range are removed from a domain, the corresponding sub-bitmap can be freed.
2) If a domain has access permissions to all host NVDIMM pages in a sub range, the corresponding sub-bitmap will be replaced by a range struct. If range structs are used to track adjacent ranges, they will be merged into one range struct. If access permissions to some pages in that sub range are removed from a domain, the range struct should be converted back to bitmap segment(s).
3) Because there might be lots of above bitmap segments and range structs per-domain, we can organize them in a balanced interval tree to quickly search/add/remove an individual structure.
In the worst case that each sub range has non-contiguous pages assigned to a domain, above solution will use all sub-bitmaps and consume more space than a single bitmap because of the extra space for organization. I assume that the sysadmin should be responsible to ensure the host nvdimm ranges assigned to each domain as contiguous and congregated as possible in order to avoid the worst case. However, if the worst case does happen, xen hypervisor should refuse to assign nvdimm to guest when it runs out of memory.
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 55 lines
Quoted 1 line
Quoted 1 line · On 08.04.16 at 07:02, <[email protected]> wrote:
Quoted 3 lines · Jan Beulich
Quoted 3 lines
Quoted 1 line
Quoted 1 line · On 29.03.16 at 12:10, <[email protected]> wrote:
Quoted 1 line · Jan Beulich
Quoted 1 line
Quoted 1 line
Quoted 1 line · On 29.03.16 at 10:47, <[email protected]> wrote:
[..]
Quoted 12 lines
Quoted 12 lines
Quoted 11 lines
Quoted 6 lines
I still cannot find a neat approach to manage guest permissions for nvdimm pages. A possible one is to use a per-domain bitmap to track
permissions: each bit corresponding to an nvdimm page. The bitmap can save lots of spaces and even be stored in the normal ram, but operating it for a large nvdimm range, especially for a contiguous one, is slower than rangeset.I don't follow: What would a single bit in that bitmap mean? Any guest may access the page? That surely wouldn't be what we need.
Quoted 7 lines
Quoted 3 lines
For a host having a N pages of nvdimm, each domain will have a N bits bitmap. If the m'th bit of a domain's bitmap is set, then that domain has the permission to access the m'th host nvdimm page.
Which will be more overhead as soon as there are enough such domains in a system.
Sorry for the late reply.
I think we can make some optimization to reduce the space consumed by the bitmap.
A per-domain bitmap covering the entire host NVDIMM address range is wasteful especially if the actual used ranges are congregated. We may take following ways to reduce its space.
1) Split the per-domain bitmap into multiple sub-bitmap and each sub-bitmap covers a smaller and contiguous sub host NVDIMM address range. In the beginning, no sub-bitmap is allocated for the domain. If the access permission to a host NVDIMM page in a sub host address range is added to a domain, only the sub-bitmap for that address range is allocated for the domain. If access permissions to all host NVDIMM pages in a sub range are removed from a domain, the corresponding sub-bitmap can be freed.
2) If a domain has access permissions to all host NVDIMM pages in a sub range, the corresponding sub-bitmap will be replaced by a range struct. If range structs are used to track adjacent ranges, they will be merged into one range struct. If access permissions to some pages in that sub range are removed from a domain, the range struct should be converted back to bitmap segment(s).
3) Because there might be lots of above bitmap segments and range structs per-domain, we can organize them in a balanced interval tree to quickly search/add/remove an individual structure.
Quoted 8 lines
In the worst case that each sub range has non-contiguous pages assigned to a domain, above solution will use all sub-bitmaps and consume more space than a single bitmap because of the extra space for organization. I assume that the sysadmin should be responsible to ensure the host nvdimm ranges assigned to each domain as contiguous and congregated as possible in order to avoid the worst case. However, if the worst case does happen, xen hypervisor should refuse to assign nvdimm to guest when it runs out of memory.
To be honest, this all sounds pretty unconvincing wrt not using existing code paths - a lot of special treatment, and hence a lot of things that can go (slightly) wrong.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 64 lines · Jan Beulich
Quoted 55 lines
Quoted 1 line
Quoted 1 line · On 08.04.16 at 07:02, <[email protected]> wrote:
Quoted 3 lines · Jan Beulich
Quoted 3 lines
Quoted 1 line
Quoted 1 line · On 29.03.16 at 12:10, <[email protected]> wrote:
Quoted 1 line · Jan Beulich
Quoted 1 line
Quoted 1 line
Quoted 1 line · On 29.03.16 at 10:47, <[email protected]> wrote:
[..]
Quoted 12 lines
Quoted 12 lines
Quoted 11 lines
Quoted 6 lines
I still cannot find a neat approach to manage guest permissions for nvdimm pages. A possible one is to use a per-domain bitmap to track
permissions: each bit corresponding to an nvdimm page. The bitmap can save lots of spaces and even be stored in the normal ram, but operating it for a large nvdimm range, especially for a contiguous one, is slower than rangeset.I don't follow: What would a single bit in that bitmap mean? Any guest may access the page? That surely wouldn't be what we need.
Quoted 7 lines
Quoted 3 lines
For a host having a N pages of nvdimm, each domain will have a N bits bitmap. If the m'th bit of a domain's bitmap is set, then that domain has the permission to access the m'th host nvdimm page.
Which will be more overhead as soon as there are enough such domains in a system.
Sorry for the late reply.
I think we can make some optimization to reduce the space consumed by the bitmap.
A per-domain bitmap covering the entire host NVDIMM address range is wasteful especially if the actual used ranges are congregated. We may take following ways to reduce its space.
1) Split the per-domain bitmap into multiple sub-bitmap and each sub-bitmap covers a smaller and contiguous sub host NVDIMM address range. In the beginning, no sub-bitmap is allocated for the domain. If the access permission to a host NVDIMM page in a sub host address range is added to a domain, only the sub-bitmap for that address range is allocated for the domain. If access permissions to all host NVDIMM pages in a sub range are removed from a domain, the corresponding sub-bitmap can be freed.
2) If a domain has access permissions to all host NVDIMM pages in a sub range, the corresponding sub-bitmap will be replaced by a range struct. If range structs are used to track adjacent ranges, they will be merged into one range struct. If access permissions to some pages in that sub range are removed from a domain, the range struct should be converted back to bitmap segment(s).
3) Because there might be lots of above bitmap segments and range structs per-domain, we can organize them in a balanced interval tree to quickly search/add/remove an individual structure.
Quoted 8 lines
In the worst case that each sub range has non-contiguous pages assigned to a domain, above solution will use all sub-bitmaps and consume more space than a single bitmap because of the extra space for organization. I assume that the sysadmin should be responsible to ensure the host nvdimm ranges assigned to each domain as contiguous and congregated as possible in order to avoid the worst case. However, if the worst case does happen, xen hypervisor should refuse to assign nvdimm to guest when it runs out of memory.
Quoted 4 lines
To be honest, this all sounds pretty unconvincing wrt not using existing code paths - a lot of special treatment, and hence a lot of things that can go (slightly) wrong.
Well, using existing range struct to manage guest access permissions to nvdimm could consume too much space which could not fit in either memory or nvdimm. If the above solution looks really error-prone, perhaps we can still come back to the existing one and restrict the number of range structs each domain could have for nvdimm (e.g. reserve one 4K-page per-domain for them) to make it work for nvdimm, though it may reject nvdimm mapping that is terribly fragmented.
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 70 lines · Haozhong Zhang
Quoted 64 lines · Jan Beulich
Quoted 55 lines
Quoted 1 line
Quoted 1 line · On 08.04.16 at 07:02, <[email protected]> wrote:
Quoted 3 lines · Jan Beulich
Quoted 3 lines
Quoted 1 line
Quoted 1 line · On 29.03.16 at 12:10, <[email protected]> wrote:
Quoted 1 line · Jan Beulich
Quoted 1 line
Quoted 1 line
Quoted 1 line · On 29.03.16 at 10:47, <[email protected]> wrote:
[..]
Quoted 12 lines
Quoted 12 lines
Quoted 11 lines
Quoted 6 lines
I still cannot find a neat approach to manage guest permissions for nvdimm pages. A possible one is to use a per-domain bitmap to track
permissions: each bit corresponding to an nvdimm page. The bitmap can save lots of spaces and even be stored in the normal ram, but operating it for a large nvdimm range, especially for a contiguous one, is slower than rangeset.I don't follow: What would a single bit in that bitmap mean? Any guest may access the page? That surely wouldn't be what we need.
Quoted 7 lines
Quoted 3 lines
For a host having a N pages of nvdimm, each domain will have a N bits bitmap. If the m'th bit of a domain's bitmap is set, then that domain has the permission to access the m'th host nvdimm page.
Which will be more overhead as soon as there are enough such domains in a system.
Sorry for the late reply.
I think we can make some optimization to reduce the space consumed by the bitmap.
A per-domain bitmap covering the entire host NVDIMM address range is wasteful especially if the actual used ranges are congregated. We may take following ways to reduce its space.
1) Split the per-domain bitmap into multiple sub-bitmap and each sub-bitmap covers a smaller and contiguous sub host NVDIMM address range. In the beginning, no sub-bitmap is allocated for the domain. If the access permission to a host NVDIMM page in a sub host address range is added to a domain, only the sub-bitmap for that address range is allocated for the domain. If access permissions to all host NVDIMM pages in a sub range are removed from a domain, the corresponding sub-bitmap can be freed.
2) If a domain has access permissions to all host NVDIMM pages in a sub range, the corresponding sub-bitmap will be replaced by a range struct. If range structs are used to track adjacent ranges, they will be merged into one range struct. If access permissions to some pages in that sub range are removed from a domain, the range struct should be converted back to bitmap segment(s).
3) Because there might be lots of above bitmap segments and range structs per-domain, we can organize them in a balanced interval tree to quickly search/add/remove an individual structure.
Quoted 8 lines
In the worst case that each sub range has non-contiguous pages assigned to a domain, above solution will use all sub-bitmaps and consume more space than a single bitmap because of the extra space for organization. I assume that the sysadmin should be responsible to ensure the host nvdimm ranges assigned to each domain as contiguous and congregated as possible in order to avoid the worst case. However, if the worst case does happen, xen hypervisor should refuse to assign nvdimm to guest when it runs out of memory.
Quoted 4 lines
To be honest, this all sounds pretty unconvincing wrt not using existing code paths - a lot of special treatment, and hence a lot of things that can go (slightly) wrong.
Quoted 8 lines
Well, using existing range struct to manage guest access permissions to nvdimm could consume too much space which could not fit in either memory or nvdimm. If the above solution looks really error-prone, perhaps we can still come back to the existing one and restrict the number of range structs each domain could have for nvdimm (e.g. reserve one 4K-page per-domain for them) to make it work for nvdimm, though it may reject nvdimm mapping that is terribly fragmented.
Hi Jan,
Any comments for this?
Thanks,
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 81 lines
Quoted 1 line
Quoted 1 line · On 21.04.16 at 07:09, <[email protected]> wrote:
Quoted 70 lines · Haozhong Zhang
Quoted 64 lines · Jan Beulich
Quoted 55 lines
Quoted 1 line
Quoted 1 line · On 08.04.16 at 07:02, <[email protected]> wrote:
Quoted 3 lines · Jan Beulich
Quoted 3 lines
Quoted 1 line
Quoted 1 line · On 29.03.16 at 12:10, <[email protected]> wrote:
Quoted 1 line · Jan Beulich
Quoted 1 line
Quoted 1 line
Quoted 1 line · On 29.03.16 at 10:47, <[email protected]> wrote:
[..]
Quoted 12 lines
Quoted 12 lines
Quoted 11 lines
Quoted 6 lines
I still cannot find a neat approach to manage guest permissions for nvdimm pages. A possible one is to use a per-domain bitmap to track
permissions: each bit corresponding to an nvdimm page. The bitmap can save lots of spaces and even be stored in the normal ram, but operating it for a large nvdimm range, especially for a contiguous one, is slower than rangeset.I don't follow: What would a single bit in that bitmap mean? Any guest may access the page? That surely wouldn't be what we need.
Quoted 7 lines
Quoted 3 lines
For a host having a N pages of nvdimm, each domain will have a N bits bitmap. If the m'th bit of a domain's bitmap is set, then that domain has the permission to access the m'th host nvdimm page.
Which will be more overhead as soon as there are enough such domains in a system.
Sorry for the late reply.
I think we can make some optimization to reduce the space consumed by the bitmap.
A per-domain bitmap covering the entire host NVDIMM address range is wasteful especially if the actual used ranges are congregated. We may take following ways to reduce its space.
1) Split the per-domain bitmap into multiple sub-bitmap and each sub-bitmap covers a smaller and contiguous sub host NVDIMM address range. In the beginning, no sub-bitmap is allocated for the domain. If the access permission to a host NVDIMM page in a sub host address range is added to a domain, only the sub-bitmap for that address range is allocated for the domain. If access permissions to all host NVDIMM pages in a sub range are removed from a domain, the corresponding sub-bitmap can be freed.
2) If a domain has access permissions to all host NVDIMM pages in a sub range, the corresponding sub-bitmap will be replaced by a range struct. If range structs are used to track adjacent ranges, they will be merged into one range struct. If access permissions to some pages in that sub range are removed from a domain, the range struct should be converted back to bitmap segment(s).
3) Because there might be lots of above bitmap segments and range structs per-domain, we can organize them in a balanced interval tree to quickly search/add/remove an individual structure.
Quoted 8 lines
In the worst case that each sub range has non-contiguous pages assigned to a domain, above solution will use all sub-bitmaps and consume more space than a single bitmap because of the extra space for organization. I assume that the sysadmin should be responsible to ensure the host nvdimm ranges assigned to each domain as contiguous and congregated as possible in order to avoid the worst case. However, if the worst case does happen, xen hypervisor should refuse to assign nvdimm to guest when it runs out of memory.
Quoted 4 lines
To be honest, this all sounds pretty unconvincing wrt not using existing code paths - a lot of special treatment, and hence a lot of things that can go (slightly) wrong.
Quoted 8 lines
Well, using existing range struct to manage guest access permissions to nvdimm could consume too much space which could not fit in either memory or nvdimm. If the above solution looks really error-prone, perhaps we can still come back to the existing one and restrict the number of range structs each domain could have for nvdimm (e.g. reserve one 4K-page per-domain for them) to make it work for nvdimm, though it may reject nvdimm mapping that is terribly fragmented.
Quoted 3 lines
Hi Jan,
Any comments for this?
Well, nothing new, i.e. my previous opinion on the old proposal didn't change. I'm really opposed to any artificial limitations here, as I am to any secondary (and hence error prone) code paths. IOW I continue to think that there's no reasonable alternative to re-using the existing memory management infrastructure for at least the PMEM case. The only open question remains to be where to place the control structures, and I think the thresholding proposal of yours was quite sensible.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 83 lines · Jan Beulich
Quoted 83 lines
Quoted 1 line
Quoted 1 line · On 21.04.16 at 07:09, <[email protected]> wrote:
Quoted 70 lines · Haozhong Zhang
Quoted 64 lines · Jan Beulich
Quoted 55 lines
Quoted 1 line
Quoted 1 line · On 08.04.16 at 07:02, <[email protected]> wrote:
Quoted 3 lines · Jan Beulich
Quoted 3 lines
Quoted 1 line
Quoted 1 line · On 29.03.16 at 12:10, <[email protected]> wrote:
Quoted 1 line · Jan Beulich
Quoted 1 line
Quoted 1 line
Quoted 1 line · On 29.03.16 at 10:47, <[email protected]> wrote:
[..]
Quoted 12 lines
Quoted 12 lines
Quoted 11 lines
Quoted 6 lines
I still cannot find a neat approach to manage guest permissions for nvdimm pages. A possible one is to use a per-domain bitmap to track
permissions: each bit corresponding to an nvdimm page. The bitmap can save lots of spaces and even be stored in the normal ram, but operating it for a large nvdimm range, especially for a contiguous one, is slower than rangeset.I don't follow: What would a single bit in that bitmap mean? Any guest may access the page? That surely wouldn't be what we need.
Quoted 7 lines
Quoted 3 lines
For a host having a N pages of nvdimm, each domain will have a N bits bitmap. If the m'th bit of a domain's bitmap is set, then that domain has the permission to access the m'th host nvdimm page.
Which will be more overhead as soon as there are enough such domains in a system.
Sorry for the late reply.
I think we can make some optimization to reduce the space consumed by the bitmap.
A per-domain bitmap covering the entire host NVDIMM address range is wasteful especially if the actual used ranges are congregated. We may take following ways to reduce its space.
1) Split the per-domain bitmap into multiple sub-bitmap and each sub-bitmap covers a smaller and contiguous sub host NVDIMM address range. In the beginning, no sub-bitmap is allocated for the domain. If the access permission to a host NVDIMM page in a sub host address range is added to a domain, only the sub-bitmap for that address range is allocated for the domain. If access permissions to all host NVDIMM pages in a sub range are removed from a domain, the corresponding sub-bitmap can be freed.
2) If a domain has access permissions to all host NVDIMM pages in a sub range, the corresponding sub-bitmap will be replaced by a range struct. If range structs are used to track adjacent ranges, they will be merged into one range struct. If access permissions to some pages in that sub range are removed from a domain, the range struct should be converted back to bitmap segment(s).
3) Because there might be lots of above bitmap segments and range structs per-domain, we can organize them in a balanced interval tree to quickly search/add/remove an individual structure.
Quoted 8 lines
In the worst case that each sub range has non-contiguous pages assigned to a domain, above solution will use all sub-bitmaps and consume more space than a single bitmap because of the extra space for organization. I assume that the sysadmin should be responsible to ensure the host nvdimm ranges assigned to each domain as contiguous and congregated as possible in order to avoid the worst case. However, if the worst case does happen, xen hypervisor should refuse to assign nvdimm to guest when it runs out of memory.
Quoted 4 lines
To be honest, this all sounds pretty unconvincing wrt not using existing code paths - a lot of special treatment, and hence a lot of things that can go (slightly) wrong.
Quoted 8 lines
Well, using existing range struct to manage guest access permissions to nvdimm could consume too much space which could not fit in either memory or nvdimm. If the above solution looks really error-prone, perhaps we can still come back to the existing one and restrict the number of range structs each domain could have for nvdimm (e.g. reserve one 4K-page per-domain for them) to make it work for nvdimm, though it may reject nvdimm mapping that is terribly fragmented.
Hi Jan,
Quoted 7 lines
Quoted 1 line
Any comments for this?
Well, nothing new, i.e. my previous opinion on the old proposal didn't change. I'm really opposed to any artificial limitations here, as I am to any secondary (and hence error prone) code paths. IOW I continue to think that there's no reasonable alternative to re-using the existing memory management infrastructure for at least the PMEM case.
By re-using the existing memory management infrastructure, do you mean re-using the existing model of MMIO for passthrough PCI devices to handle the permission of pmem?
Quoted 3 lines
The
only open question remains to be where to place the control structures, and I think the thresholding proposal of yours was quite sensible.
I'm little confused here. Is 'restrict the number of range structs' in my previous reply the 'thresholding proposal' you mean? Or it's one of 'artificial limitations'?
Thanks,
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 93 lines
Quoted 1 line
Quoted 1 line · On 22.04.16 at 04:36, <[email protected]> wrote:
Quoted 83 lines · Jan Beulich
Quoted 83 lines
Quoted 1 line
Quoted 1 line · On 21.04.16 at 07:09, <[email protected]> wrote:
Quoted 70 lines · Haozhong Zhang
Quoted 64 lines · Jan Beulich
Quoted 55 lines
Quoted 1 line
Quoted 1 line · On 08.04.16 at 07:02, <[email protected]> wrote:
Quoted 3 lines · Jan Beulich
Quoted 3 lines
Quoted 1 line
Quoted 1 line · On 29.03.16 at 12:10, <[email protected]> wrote:
Quoted 1 line · Jan Beulich
Quoted 1 line
Quoted 1 line
Quoted 1 line · On 29.03.16 at 10:47, <[email protected]> wrote:
[..]
Quoted 12 lines
Quoted 12 lines
Quoted 11 lines
Quoted 6 lines
I still cannot find a neat approach to manage guest permissions for nvdimm pages. A possible one is to use a per-domain bitmap to track
permissions: each bit corresponding to an nvdimm page. The bitmap can save lots of spaces and even be stored in the normal ram, but operating it for a large nvdimm range, especially for a contiguous one, is slower than rangeset.I don't follow: What would a single bit in that bitmap mean? Any guest may access the page? That surely wouldn't be what we need.
Quoted 7 lines
Quoted 3 lines
For a host having a N pages of nvdimm, each domain will have a N bits bitmap. If the m'th bit of a domain's bitmap is set, then that domain has the permission to access the m'th host nvdimm page.
Which will be more overhead as soon as there are enough such domains in a system.
Sorry for the late reply.
I think we can make some optimization to reduce the space consumed by the bitmap.
A per-domain bitmap covering the entire host NVDIMM address range is wasteful especially if the actual used ranges are congregated. We may take following ways to reduce its space.
1) Split the per-domain bitmap into multiple sub-bitmap and each sub-bitmap covers a smaller and contiguous sub host NVDIMM address range. In the beginning, no sub-bitmap is allocated for the domain. If the access permission to a host NVDIMM page in a sub host address range is added to a domain, only the sub-bitmap for that address range is allocated for the domain. If access permissions to all host NVDIMM pages in a sub range are removed from a domain, the corresponding sub-bitmap can be freed.
2) If a domain has access permissions to all host NVDIMM pages in a sub range, the corresponding sub-bitmap will be replaced by a range struct. If range structs are used to track adjacent ranges, they will be merged into one range struct. If access permissions to some pages in that sub range are removed from a domain, the range struct should be converted back to bitmap segment(s).
3) Because there might be lots of above bitmap segments and range structs per-domain, we can organize them in a balanced interval tree to quickly search/add/remove an individual structure.
Quoted 8 lines
In the worst case that each sub range has non-contiguous pages assigned to a domain, above solution will use all sub-bitmaps and consume more space than a single bitmap because of the extra space for organization. I assume that the sysadmin should be responsible to ensure the host nvdimm ranges assigned to each domain as contiguous and congregated as possible in order to avoid the worst case. However, if the worst case does happen, xen hypervisor should refuse to assign nvdimm to guest when it runs out of memory.
Quoted 4 lines
To be honest, this all sounds pretty unconvincing wrt not using existing code paths - a lot of special treatment, and hence a lot of things that can go (slightly) wrong.
Quoted 8 lines
Well, using existing range struct to manage guest access permissions to nvdimm could consume too much space which could not fit in either memory or nvdimm. If the above solution looks really error-prone, perhaps we can still come back to the existing one and restrict the number of range structs each domain could have for nvdimm (e.g. reserve one 4K-page per-domain for them) to make it work for nvdimm, though it may reject nvdimm mapping that is terribly fragmented.
Hi Jan,
Quoted 7 lines
Quoted 1 line
Any comments for this?
Well, nothing new, i.e. my previous opinion on the old proposal didn't change. I'm really opposed to any artificial limitations here, as I am to any secondary (and hence error prone) code paths. IOW I continue to think that there's no reasonable alternative to re-using the existing memory management infrastructure for at least the PMEM case.
Quoted 3 lines
By re-using the existing memory management infrastructure, do you mean re-using the existing model of MMIO for passthrough PCI devices to handle the permission of pmem?
No, re-using struct page_info.
Quoted 7 lines
Quoted 3 lines
The
only open question remains to be where to place the control structures, and I think the thresholding proposal of yours was quite sensible.I'm little confused here. Is 'restrict the number of range structs' in my previous reply the 'thresholding proposal' you mean? Or it's one of 'artificial limitations'?
Neither. It's the decision on where to place the struct page_info arrays needed to manage the PMEM ranges.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
On 04/22/16 02:24, Jan Beulich wrote:
[..]
Quoted 29 lines
Quoted 19 lines
Quoted 11 lines
Quoted 11 lines
Quoted 8 lines
Well, using existing range struct to manage guest access permissions to nvdimm could consume too much space which could not fit in either memory or nvdimm. If the above solution looks really error-prone, perhaps we can still come back to the existing one and restrict the number of range structs each domain could have for nvdimm (e.g. reserve one 4K-page per-domain for them) to make it work for nvdimm, though it may reject nvdimm mapping that is terribly fragmented.
Hi Jan,
Quoted 7 lines
Quoted 1 line
Any comments for this?
Well, nothing new, i.e. my previous opinion on the old proposal didn't change. I'm really opposed to any artificial limitations here, as I am to any secondary (and hence error prone) code paths. IOW I continue to think that there's no reasonable alternative to re-using the existing memory management infrastructure for at least the PMEM case.
Quoted 3 lines
By re-using the existing memory management infrastructure, do you mean re-using the existing model of MMIO for passthrough PCI devices to handle the permission of pmem?
No, re-using struct
page_info.Quoted 4 lines
Quoted 3 lines
The
only open question remains to be where to place the control structures, and I think the thresholding proposal of yours was quite sensible.
Quoted 7 lines
Quoted 3 lines
I'm little confused here. Is 'restrict the number of range structs' in my previous reply the 'thresholding proposal' you mean? Or it's one of 'artificial limitations'?
Neither. It's the decision on where to place the struct
page_infoarrays needed to manage the PMEM ranges.
In [1][2], we have agreed to use struct page_info to manage mappings for pmem and place them in reserved area on pmem.
But I think the discussion in this thread is to decide the data structure which will be used to track access permission to host pmem. The discussion started from my question in [3]:
| I'm not sure whether xen toolstack as a userspace program is | considered to be safe to pass the host physical address (of host | NVDIMM) to hypervisor. In reply [4], you mentioned: | As long as the passing of physical addresses follows to model of | MMIO for passed through PCI devices, I don't think there's problem | with the tool stack bypassing the Dom0 kernel. So it really all | depends on how you make sure that the guest won't get to see memory | it has no permission to access.
I interpreted it as the same access permission control mechanism used for MMIO of passthrough pci devices (built around range struct) should be used for pmem as well, so that we can safely allow toolstack to pass the host physical address of nvdimm to hypervisor.
Was my understanding wrong from the beginning?
Thanks,
Haozhong
[1] http://lists.xenproject.org/archives/html/xen-devel/2016-03/msg01161.html
[2] http://lists.xenproject.org/archives/html/xen-devel/2016-03/msg01201.html
[3] http://lists.xenproject.org/archives/html/xen-devel/2016-03/msg01972.html
[4] http://lists.xenproject.org/archives/html/xen-devel/2016-03/msg01981.html
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 56 lines
Quoted 1 line
Quoted 1 line · On 22.04.16 at 12:16, <[email protected]> wrote:
On 04/22/16 02:24, Jan Beulich wrote:
[..]Quoted 29 lines
Quoted 19 lines
Quoted 11 lines
Quoted 11 lines
Quoted 8 lines
Well, using existing range struct to manage guest access permissions to nvdimm could consume too much space which could not fit in either memory or nvdimm. If the above solution looks really error-prone, perhaps we can still come back to the existing one and restrict the number of range structs each domain could have for nvdimm (e.g. reserve one 4K-page per-domain for them) to make it work for nvdimm, though it may reject nvdimm mapping that is terribly fragmented.
Hi Jan,
Quoted 7 lines
Quoted 1 line
Any comments for this?
Well, nothing new, i.e. my previous opinion on the old proposal didn't change. I'm really opposed to any artificial limitations here, as I am to any secondary (and hence error prone) code paths. IOW I continue to think that there's no reasonable alternative to re-using the existing memory management infrastructure for at least the PMEM case.
Quoted 3 lines
By re-using the existing memory management infrastructure, do you mean re-using the existing model of MMIO for passthrough PCI devices to handle the permission of pmem?
No, re-using struct
page_info.Quoted 4 lines
Quoted 3 lines
The
only open question remains to be where to place the control structures, and I think the thresholding proposal of yours was quite sensible.Quoted 7 lines
Quoted 3 lines
I'm little confused here. Is 'restrict the number of range structs' in my previous reply the 'thresholding proposal' you mean? Or it's one of 'artificial limitations'?
Neither. It's the decision on where to place the struct
page_infoarrays needed to manage the PMEM ranges.In [1][2], we have agreed to use struct
page_infoto manage mappings for pmem and place them in reserved area on pmem.But I think the discussion in this thread is to decide the data structure which will be used to track access permission to host pmem. The discussion started from my question in [3]:
| I'm not sure whether xen toolstack as a userspace program is | considered to be safe to pass the host physical address (of host | NVDIMM) to hypervisor. In reply [4], you mentioned: | As long as the passing of physical addresses follows to model of | MMIO for passed through PCI devices, I don't think there's problem | with the tool stack bypassing the Dom0 kernel. So it really all | depends on how you make sure that the guest won't get to see memory | it has no permission to access.
Quoted 5 lines
I interpreted it as the same access permission control mechanism used for MMIO of passthrough pci devices (built around range struct) should be used for pmem as well, so that we can safely allow toolstack to pass the host physical address of nvdimm to hypervisor.
Was my understanding wrong from the beginning?
Perhaps I have got confused by the back and forth. If we're to use struct page_info, then everything should be following a similar flow to what happens for normal RAM, i.e. normal page allocation, and normal assignment of pages to guests.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 62 lines · Jan Beulich
Quoted 56 lines
Quoted 1 line
Quoted 1 line · On 22.04.16 at 12:16, <[email protected]> wrote:
On 04/22/16 02:24, Jan Beulich wrote:
[..]Quoted 29 lines
Quoted 19 lines
Quoted 11 lines
Quoted 11 lines
Quoted 8 lines
Well, using existing range struct to manage guest access permissions to nvdimm could consume too much space which could not fit in either memory or nvdimm. If the above solution looks really error-prone, perhaps we can still come back to the existing one and restrict the number of range structs each domain could have for nvdimm (e.g. reserve one 4K-page per-domain for them) to make it work for nvdimm, though it may reject nvdimm mapping that is terribly fragmented.
Hi Jan,
Quoted 7 lines
Quoted 1 line
Any comments for this?
Well, nothing new, i.e. my previous opinion on the old proposal didn't change. I'm really opposed to any artificial limitations here, as I am to any secondary (and hence error prone) code paths. IOW I continue to think that there's no reasonable alternative to re-using the existing memory management infrastructure for at least the PMEM case.
Quoted 3 lines
By re-using the existing memory management infrastructure, do you mean re-using the existing model of MMIO for passthrough PCI devices to handle the permission of pmem?
No, re-using struct
page_info.Quoted 4 lines
Quoted 3 lines
The
only open question remains to be where to place the control structures, and I think the thresholding proposal of yours was quite sensible.Quoted 7 lines
Quoted 3 lines
I'm little confused here. Is 'restrict the number of range structs' in my previous reply the 'thresholding proposal' you mean? Or it's one of 'artificial limitations'?
Neither. It's the decision on where to place the struct
page_infoarrays needed to manage the PMEM ranges.In [1][2], we have agreed to use struct
page_infoto manage mappings for pmem and place them in reserved area on pmem.But I think the discussion in this thread is to decide the data structure which will be used to track access permission to host pmem. The discussion started from my question in [3]:
| I'm not sure whether xen toolstack as a userspace program is | considered to be safe to pass the host physical address (of host | NVDIMM) to hypervisor. In reply [4], you mentioned: | As long as the passing of physical addresses follows to model of | MMIO for passed through PCI devices, I don't think there's problem | with the tool stack bypassing the Dom0 kernel. So it really all | depends on how you make sure that the guest won't get to see memory | it has no permission to access.Quoted 5 lines
I interpreted it as the same access permission control mechanism used for MMIO of passthrough pci devices (built around range struct) should be used for pmem as well, so that we can safely allow toolstack to pass the host physical address of nvdimm to hypervisor.
Was my understanding wrong from the beginning?
Quoted 5 lines
Perhaps I have got confused by the back and forth. If we're to use struct
page_info, then everything should be following a similar flow to what happens for normal RAM, i.e. normal page allocation, and normal assignment of pages to guests.
I'll follow the normal assignment of pages to guests for pmem, but not the normal page allocation. Because allocation is difficult to always get the same pmem area for the same guest every time. It still needs input from others (e.g. toolstack) that can provide the exact address.
Because the address is now not decided by xen hypervisor, certain permission track is needed. For this part, we will re-use the existing one for MMIO. Directly using existing range struct for pmem may consume too much space, so I proposed to choose different data structures or put limitation on exiting range struct to avoid or mitigate this problem. The data structure change will be applied only to pmem, and only the code that manipulate the range structs (rangeset_*) will be changed for pmem. So for the permission tracking part, it will still follow the exiting one.
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 8 lines
Quoted 1 line
Quoted 1 line · On 22.04.16 at 14:26, <[email protected]> wrote:
Quoted 5 lines · Jan Beulich
Perhaps I have got confused by the back and forth. If we're to use struct
page_info, then everything should be following a similar flow to what happens for normal RAM, i.e. normal page allocation, and normal assignment of pages to guests.
Quoted 4 lines
I'll follow the normal assignment of pages to guests for pmem, but not the normal page allocation. Because allocation is difficult to always get the same pmem area for the same guest every time. It still needs input from others (e.g. toolstack) that can provide the exact address.
Understood.
Quoted 6 lines
Because the address is now not decided by xen hypervisor, certain permission track is needed. For this part, we will re-use the existing one for MMIO. Directly using existing range struct for pmem may consume too much space, so I proposed to choose different data structures or put limitation on exiting range struct to avoid or mitigate this problem.
Why would these consume too much space? I'd expect there to be just one or very few chunks, just like is the case for MMIO ranges on devices.
Jan
Quoted 6 lines
The data structure change will be applied only
to pmem, and only the code that manipulate the range structs (rangeset_*) will be changed for pmem. So for the permission tracking part, it will still follow the exiting one.Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 22 lines · Jan Beulich
Quoted 8 lines
Quoted 1 line
Quoted 1 line · On 22.04.16 at 14:26, <[email protected]> wrote:
Quoted 5 lines · Jan Beulich
Perhaps I have got confused by the back and forth. If we're to use struct
page_info, then everything should be following a similar flow to what happens for normal RAM, i.e. normal page allocation, and normal assignment of pages to guests.Quoted 4 lines
I'll follow the normal assignment of pages to guests for pmem, but not the normal page allocation. Because allocation is difficult to always get the same pmem area for the same guest every time. It still needs input from others (e.g. toolstack) that can provide the exact address.
Understood.
Quoted 6 lines
Because the address is now not decided by xen hypervisor, certain permission track is needed. For this part, we will re-use the existing one for MMIO. Directly using existing range struct for pmem may consume too much space, so I proposed to choose different data structures or put limitation on exiting range struct to avoid or mitigate this problem.
Quoted 4 lines
Why would these consume too much space? I'd expect there to be just one or very few chunks, just like is the case for MMIO ranges on devices.
As Ian Jackson indicated [1], there are several cases that a pmem page can be accessed from more than one domains. Then every domain involved needs a range struct to track its access permission to that pmem page. In a worst case, e.g. the first of every two contiguous pages on a pmem are assigned to a domain and are shared with all other domains, though the size of range struct for a single domain maybe acceptable, the total will still be very large.
Haozhong
[1] http://lists.xenproject.org/archives/html/xen-devel/2016-03/msg02309.html
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 28 lines
Quoted 1 line
Quoted 1 line · On 22.04.16 at 14:54, <[email protected]> wrote:
Quoted 22 lines · Jan Beulich
Quoted 8 lines
Quoted 1 line
Quoted 1 line · On 22.04.16 at 14:26, <[email protected]> wrote:
Quoted 5 lines · Jan Beulich
Perhaps I have got confused by the back and forth. If we're to use struct
page_info, then everything should be following a similar flow to what happens for normal RAM, i.e. normal page allocation, and normal assignment of pages to guests.Quoted 4 lines
I'll follow the normal assignment of pages to guests for pmem, but not the normal page allocation. Because allocation is difficult to always get the same pmem area for the same guest every time. It still needs input from others (e.g. toolstack) that can provide the exact address.
Understood.
Quoted 6 lines
Because the address is now not decided by xen hypervisor, certain permission track is needed. For this part, we will re-use the existing one for MMIO. Directly using existing range struct for pmem may consume too much space, so I proposed to choose different data structures or put limitation on exiting range struct to avoid or mitigate this problem.
Quoted 3 lines
Why would these consume too much space? I'd expect there to be just one or very few chunks, just like is the case for MMIO ranges on devices.
Quoted 7 lines
As Ian Jackson indicated [1], there are several cases that a pmem page can be accessed from more than one domains. Then every domain involved needs a range struct to track its access permission to that pmem page. In a worst case, e.g. the first of every two contiguous pages on a pmem are assigned to a domain and are shared with all other domains, though the size of range struct for a single domain maybe acceptable, the total will still be very large.
Everything Ian has mentioned there is what normal RAM pages also can get used for, yes as you have yourself said (still visible in context above) you mean to only do allocation differently. Hence the permission tracking you talk of should be necessary only for the owning domain (to get validated during allocation), everything else should follow the normal life cycle of a RAM page.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 3 lines
Then there is another problem (which also exists in the current design): does Xen need to emulate NVDIMM
_DSMfor dom0? Take the_DSMthat access label storage area (for namespace) for example:
No. And it really can't as each vendors _DSM is different - and there is no ACPI AML interpreter inside Xen hypervisor.
Quoted 11 lines
The way Linux reserving space on pmem mode NVDIMM is to leave the reserved space at the beginning of pmem mode NVDIMM and create a pmem namespace which starts from the end of the reserved space. Because the reservation information is written in the namespace in the NVDIMM label storage area, every OS that follows the namespace spec would not mistakenly write files in the reserved area. I prefer to the same way if Xen is going to do the reservation. We definitely don't want dom0 to break the label storage area, so Xen seemingly needs to emulate the corresponding
_DSMfunctions for dom0? If so, which part, the hypervisor or the toolstack, should do the emulation?
But we do not want Xen to do the reservation. The control guest (Dom0) is the one that will mount the NVDIMM, and extract the system ranges from the files on the NVDIMM - and glue them to a guest.
It is also the job of Dom0 to do the actually partition the NVDIMM as fit. Actually let me step back. It is the job of the guest who has the full NVDIMM in it. At bootup it is Dom0 - but you can very well 'unplug' the NVDIMM from Dom0 and assign it wholesale to a guest.
Granted at that point the _DSM operations have to go through QEMU which ends up calling the dom0 ioctls on PMEM to do the operation (like getting the SMART data).
Quoted 2 lines
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 6 lines
Quoted 6 lines
Quoted 6 lines
Quoted 5 lines
Open: It seems no system call/ioctl is provided by Linux kernel to
get the physical address from a virtual address. /proc/<qemu_pid>/pagemap provides information of mapping from VA to PA. Is it an acceptable solution to let QEMU parse this file to get the physical address?
Quoted 8 lines
Quoted 8 lines
Quoted 2 lines
Does it work in a non-root scenario?
Seemingly no, according to
Documentation/vm/pagemap.txtin Linux kernel:| Since Linux 4.0 only users with the CAP_SYS_ADMIN capability can get PFNs. | In 4.0 and 4.1 opens by unprivileged fail with -EPERM. Starting from | 4.2 the PFN field is zeroed if the user does not have CAP_SYS_ADMIN. | Reason: information about PFNs helps in exploiting Rowhammer vulnerability.
Ah right.
Quoted 6 lines
Quoted 4 lines
A possible alternative is to add a new hypercall similar to
XEN_DOMCTL_memory_mappingbut receiving virtual address as the address parameter and translating to machine address in the hypervisor.That might work.
That won't work.
This is a userspace VMA - which means the once the ioctl is done we swap to kernel virtual addresses. Now we may know that the prior cr3 has the userspace virtual address and walk it down - but what if the domain that is doing this is PVH? (or HVM) - the cr3 of userspace is tucked somewhere inside the kernel.
Which means this hypercall would need to know the Linux kernel task structure to find this.
May I propose another solution - an stacking driver (similar to loop). You setup it up (ioctl /dev/pmem0/guest.img, get some /dev/mapper/guest.img created). Then mmap the /dev/mapper/guest.img - all of the operations are the same - except it may have an extra ioctl - get_pfns - which would provide the data in similar form to pagemap.txt.
But folks will then ask - why don't you just use pagemap? Could the pagemap have an extra security capability check? One that can be set for QEMU?
Quoted 9 lines
Quoted 9 lines
Quoted 9 lines
Quoted 8 lines
Open: For a large pmem, mmap(2) is very possible to not map all SPA
occupied by pmem at the beginning, i.e. QEMU may not be able to get all SPA of pmem from buf (in virtual address space) when callingXEN_DOMCTL_memory_mapping.
Can mmap flagMAP_LOCKEDor mlock(2) be used to enforce the entire pmem being mmaped?
Quoted 7 lines
Quoted 7 lines
Quoted 2 lines
Ditto
No. If I take the above alternative for the first open, maybe the new hypercall above can inject page faults into dom0 for the unmapped virtual address so as to enforce dom0 Linux to create the page mapping.
Ugh. That sounds hacky. And you wouldn't neccessarily be safe. Imagine that the system admin decides to defrag the /dev/pmem filesystem. Or move the files (disk images) around. If they do that - we may still have the guest mapped to system addresses which may contain filesystem metadata now, or a different guest image. We MUST mlock or lock the file during the duration of the guest.
Quoted 25 lines · Konrad Rzeszutek Wilk
Quoted 6 lines
Quoted 6 lines
Quoted 6 lines
Quoted 5 lines
Open: It seems no system call/ioctl is provided by Linux kernel to
get the physical address from a virtual address. /proc/<qemu_pid>/pagemap provides information of mapping from VA to PA. Is it an acceptable solution to let QEMU parse this file to get the physical address?Quoted 8 lines
Quoted 8 lines
Quoted 2 lines
Does it work in a non-root scenario?
Seemingly no, according to
Documentation/vm/pagemap.txtin Linux kernel:| Since Linux 4.0 only users with the CAP_SYS_ADMIN capability can get PFNs. | In 4.0 and 4.1 opens by unprivileged fail with -EPERM. Starting from | 4.2 the PFN field is zeroed if the user does not have CAP_SYS_ADMIN. | Reason: information about PFNs helps in exploiting Rowhammer vulnerability.Ah right.
Quoted 6 lines
Quoted 4 lines
A possible alternative is to add a new hypercall similar to
XEN_DOMCTL_memory_mappingbut receiving virtual address as the address parameter and translating to machine address in the hypervisor.That might work.
That won't work.
Quoted 9 lines
This is a userspace VMA - which means the once the ioctl is done we swap to kernel virtual addresses. Now we may know that the prior cr3 has the userspace virtual address and walk it down - but what if the domain that is doing this is PVH? (or HVM) - the cr3 of userspace is tucked somewhere inside the kernel.
Which means this hypercall would need to know the Linux kernel task structure to find this.
Thanks for pointing out this. Really it's not a workable solution.
Quoted 6 lines
May I propose another solution - an stacking driver (similar to loop). You setup it up (ioctl
/dev/pmem0/guest.img, get some/dev/mapper/guest.imgcreated). Then mmap the/dev/mapper/guest.img- all of the operations are the same - except it may have an extra ioctl -get_pfns- which would provide the data in similar form to pagemap.txt.
I'll have a look at this, thanks!
Quoted 4 lines
But folks will then ask - why don't you just use pagemap? Could the pagemap have an extra security capability check? One that can be set for QEMU?
Basically for the concern on whether non-root QEMU could work as in Stefano's comments.
Quoted 17 lines
Quoted 9 lines
Quoted 9 lines
Quoted 9 lines
Quoted 8 lines
Open: For a large pmem, mmap(2) is very possible to not map all SPA
occupied by pmem at the beginning, i.e. QEMU may not be able to get all SPA of pmem from buf (in virtual address space) when callingXEN_DOMCTL_memory_mapping.
Can mmap flagMAP_LOCKEDor mlock(2) be used to enforce the entire pmem being mmaped?Quoted 7 lines
Quoted 7 lines
Quoted 2 lines
Ditto
No. If I take the above alternative for the first open, maybe the new hypercall above can inject page faults into dom0 for the unmapped virtual address so as to enforce dom0 Linux to create the page mapping.
Quoted 8 lines
Ugh. That sounds hacky. And you wouldn't neccessarily be safe. Imagine that the system admin decides to defrag the
/dev/pmemfilesystem. Or move the files (disk images) around. If they do that - we may still have the guest mapped to system addresses which may contain filesystem metadata now, or a different guest image. We MUST mlock or lock the file during the duration of the guest.
So mlocking or locking the mmaped file, or other ways to 'pin' the mmaped file on pmem is a necessity.
Thanks,
Haozhong
Quoted 31 lines · Konrad Rzeszutek Wilk
Quoted 6 lines
Quoted 6 lines
Quoted 6 lines
Quoted 5 lines
Open: It seems no system call/ioctl is provided by Linux kernel to
get the physical address from a virtual address. /proc/<qemu_pid>/pagemap provides information of mapping from VA to PA. Is it an acceptable solution to let QEMU parse this file to get the physical address?Quoted 8 lines
Quoted 8 lines
Quoted 2 lines
Does it work in a non-root scenario?
Seemingly no, according to
Documentation/vm/pagemap.txtin Linux kernel:| Since Linux 4.0 only users with the CAP_SYS_ADMIN capability can get PFNs. | In 4.0 and 4.1 opens by unprivileged fail with -EPERM. Starting from | 4.2 the PFN field is zeroed if the user does not have CAP_SYS_ADMIN. | Reason: information about PFNs helps in exploiting Rowhammer vulnerability.Ah right.
Quoted 6 lines
Quoted 4 lines
A possible alternative is to add a new hypercall similar to
XEN_DOMCTL_memory_mappingbut receiving virtual address as the address parameter and translating to machine address in the hypervisor.That might work.
That won't work.
This is a userspace VMA - which means the once the ioctl is done we swap to kernel virtual addresses. Now we may know that the prior cr3 has the userspace virtual address and walk it down - but what if the domain that is doing this is PVH? (or HVM) - the cr3 of userspace is tucked somewhere inside the kernel.
Quoted 9 lines
Which means this hypercall would need to know the Linux kernel task structure to find this.
May I propose another solution - an stacking driver (similar to loop). You setup it up (ioctl
/dev/pmem0/guest.img, get some/dev/mapper/guest.imgcreated). Then mmap the/dev/mapper/guest.img- all of the operations are the same - except it may have an extra ioctl -get_pfns- which would provide the data in similar form to pagemap.txt.
This stack driver approach seems still need privileged permission and more modifications in kernel, so ...
Quoted 4 lines
But folks will then ask - why don't you just use pagemap? Could the pagemap have an extra security capability check? One that can be set for QEMU?
... I would like to use pagemap and mlock.
Haozhong
Quoted 29 lines
Quoted 9 lines
Quoted 9 lines
Quoted 9 lines
Quoted 8 lines
Open: For a large pmem, mmap(2) is very possible to not map all SPA
occupied by pmem at the beginning, i.e. QEMU may not be able to get all SPA of pmem from buf (in virtual address space) when callingXEN_DOMCTL_memory_mapping.
Can mmap flagMAP_LOCKEDor mlock(2) be used to enforce the entire pmem being mmaped?Quoted 7 lines
Quoted 7 lines
Quoted 2 lines
Ditto
No. If I take the above alternative for the first open, maybe the new hypercall above can inject page faults into dom0 for the unmapped virtual address so as to enforce dom0 Linux to create the page mapping.
Ugh. That sounds hacky. And you wouldn't neccessarily be safe. Imagine that the system admin decides to defrag the
/dev/pmemfilesystem. Or move the files (disk images) around. If they do that - we may still have the guest mapped to system addresses which may contain filesystem metadata now, or a different guest image. We MUST mlock or lock the file during the duration of the guest._______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 1 line
3. Design of vNVDIMM in Xen
Thank you for this design!
Quoted 6 lines
Similarly to that in KVM/QEMU, enabling vNVDIMM in Xen is composed of three parts:
(1) Guest clwb/clflushopt/pcommit enabling,
(2) Memory mapping, and
(3) Guest ACPI emulation.
.. MCE? and vMCE?
Quoted 8 lines
The rest of this section present the design of each part respectively. The basic design principle to reuse existing code in Linux NVDIMM driver and QEMU as much as possible. As recent discussions in the both Xen and QEMU mailing lists for the v1 patch series, alternative designs are also listed below.
Quoted 5 lines
3.1 Guest clwb/clflushopt/pcommit Enabling
The instruction enabling is simple and we do the same work as in KVM/QEMU.
- All three instructions are exposed to guest via guest cpuid.
- L1 guest pcommit is never intercepted by Xen.
I wish there was some watermarks like the PLE has.
My fear is that an unfriendly guest can issue sfence all day long flushing out other guests MMC queue (the writes followed by pcommits). Which means that an guest may have degraded performance as their memory writes are being flushed out immediately as if they were being written to UC instead of WB memory.
In other words - the NVDIMM resource does not provide any resource isolation. However this may not be any different than what we had nowadays with CPU caches.
Quoted 1 line
- L1 hypervisor is allowed to intercept L2 guest pcommit.
clwb?
Quoted 46 lines
3.2 Address Mapping
3.2.1 My Design
The overview of this design is shown in the following figure.
Dom0 | DomU | | QEMU | +...+--------------------+...+-----+ | VA | | Label Storage Area | | buf | | +...+--------------------+...+-----+ | ^ ^ ^ | | | | | V | | | +-------+ +-------+ mmap(2) | | vACPI | | v_DSM | | | | +----+------------+ +-------+ +-------+ | | | SPA | | /dev/pmem0 | ^ ^ +------+ | | +----+------------+ --------|-----------|-----|------------|-- | ^ ^ | | | | | | | | +------+ +------------~-----~-------------+ | | | | | | XEN_DOMCTL_memory_mapping | | | +-----~--------------------------+ | | | | | | | +----+------------+ | Linux | | SPA | | /dev/pmem0 | | +------+ +------+ | | +----+------------+ | | ACPI | | _DSM | | | ^ | +------+ +------+ | | | | | | | | Dom0 Driver | hvmloader/xl | --------|----|-------------------|---------------------|----------|--------------- | +-------------------~---------------------~----------+ Xen | | | +------------------------~---------------------+ ---------------------------------|------------------------------------------------ +----------------+ | +-------------+ HW | NVDIMM | +-------------+
Quoted 1 line
This design treats host NVDIMM devices as ordinary MMIO devices:
Nice.
But it also means you need Xen to 'share' the ranges of an MMIO device.
That is you may need dom0 _DSM method to access certain ranges (the AML code may need to poke there) - and the guest may want to access those as well.
And keep in mind that this NVDIMM management may not need to be always in initial domain. As in you could have NVDIMM device drivers that would carve out the ranges to guests.
Quoted 66 lines
(1) Dom0 Linux NVDIMM driver is responsible to detect (through NFIT) and drive host NVDIMM devices (implementing block device interface). Namespaces and file systems on host NVDIMM devices are handled by Dom0 Linux as well.
(2) QEMU mmap(2) the pmem NVDIMM devices (
/dev/pmem0) into its virtual address space (buf).(3) QEMU gets the host physical address of buf, i.e. the host system physical address that is occupied by
/dev/pmem0, and calls Xen hypercallXEN_DOMCTL_memory_mappingto map it to a DomU.(ACPI part is described in Section 3.3 later)
Above (1)(2) have already been done in current QEMU. Only (3) is needed to implement in QEMU. No change is needed in Xen for address mapping in this design.
Open: It seems no system call/ioctl is provided by Linux kernel to
get the physical address from a virtual address. /proc/<qemu_pid>/pagemap provides information of mapping from VA to PA. Is it an acceptable solution to let QEMU parse this file to get the physical address?Open: For a large pmem, mmap(2) is very possible to not map all SPA
occupied by pmem at the beginning, i.e. QEMU may not be able to get all SPA of pmem from buf (in virtual address space) when callingXEN_DOMCTL_memory_mapping.
Can mmap flagMAP_LOCKEDor mlock(2) be used to enforce the entire pmem being mmaped?3.2.2 Alternative Design
Jan Beulich's comments [7] on my question "why must pmem resource management and partition be done in hypervisor":
| Because that's where memory management belongs. And PMEM, | other than PBLK, is just another form of RAM. | ... | The main issue is that this would imo be a layering violationGeorge Dunlap's comments [8]:
| This is not the case for PMEM. The whole point of PMEM (correct me if
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ used as fungible ram| I'm wrong) is to be used for long-term storage that survives over | reboot. It matters very much that a guest be given the same PRAM | after the host is rebooted that it was given before. It doesn't make | any sense to manage it the way Xen currently manages RAM (i.e., that | you request a page and get whatever Xen happens to give you). | | So if Xen is going to use PMEM, it will have to invent an entirely new | interface for guests, and it will have to keep track of those | resources across host reboots. In other words, it will have to | duplicate all the work that Linux already does. What do we gain from | that duplication? Why not just leverage what's already implemented in | dom0? and [9]: | Oh, right -- yes, if the usage model of PRAM is just "cheap slow RAM", | then you're right -- it is just another form of RAM, that should be | treated no differently than say, lowmem: a fungible resource that can be | requested by setting a flag.However, pmem is used more as persistent storage than fungible ram, and my design is for the former usage. I would like to leave the detection, driver and partition (either through namespace or file systems) of NVDIMM in Dom0 Linux kernel.
Quoted 5 lines
I notice that current
XEN_DOMCTL_memory_mappingdoes not make santiy check for the physical address and size passed from caller (QEMU). Can QEMU be always trusted? If not, we would need to make Xen aware of the SPA range of pmem so that it can refuse map physical address in neither the normal ram nor pmem.
/me nods.
Quoted 24 lines
Instead of duplicating the detection code (parsing NFIT and evaluating
_FIT) in Dom0 Linux kernel, we decide to patch Dom0 Linux kernel to pass parameters of host pmem NVDIMM devices to Xen hypervisor:
(1) Add a global
struct rangesetpmem_rangeset
in Xen hypervisor to record all SPA ranges of detected pmem devices. Each range inpmem_rangesetcorresponds to a pmem device.(2) Add a hypercall
XEN_SYSCTL_add_pmem_range
(should it be a sysctl or a platform op?)
that receives a pair of parameters (addr: starting SPA of pmem region, len: size of pmem region) and add a range (addr, addr + len - 1) innvdimm_rangset.(3) Add a hypercall
XEN_DOMCTL_pmem_mapping
that takes the same parameters asXEN_DOMCTL_memory_mappingand maps a given host pmem range to guest. It checks whether the given host pmem range is in thepmem_rangesetbefore making the actual mapping.
Quoted 5 lines
(4) Patch Linux NVDIMM driver to call
XEN_SYSCTL_add_pmem_rangewhenever it detects a pmem device.(5) Patch QEMU to use
XEN_DOMCTL_pmem_mappingfor mapping host pmem devices.
That is nice - as you can instrument this on existing hardware and create 'fake' starting SPA for real memory - which Xen may not see due to being booted with 'mem=X'.
Quoted 5 lines · Konrad Rzeszutek Wilk
Quoted 1 line
3. Design of vNVDIMM in Xen
Thank you for this design!
Quoted 1 line
Quoted 9 lines
Quoted 5 lines
Similarly to that in KVM/QEMU, enabling vNVDIMM in Xen is composed of three parts:
(1) Guest clwb/clflushopt/pcommit enabling,
(2) Memory mapping, and
(3) Guest ACPI emulation... MCE? and vMCE?
Specifications on my hand seem not mention much about MCE for NVDIMM, but I remember that NVDIMM driver in Linux kernel does have MCE code. I'll have a look at that code and add this part later.
Quoted 14 lines
Quoted 8 lines
The rest of this section present the design of each part respectively. The basic design principle to reuse existing code in Linux NVDIMM driver and QEMU as much as possible. As recent discussions in the both Xen and QEMU mailing lists for the v1 patch series, alternative designs are also listed below.
Quoted 5 lines
3.1 Guest clwb/clflushopt/pcommit Enabling
The instruction enabling is simple and we do the same work as in KVM/QEMU.
- All three instructions are exposed to guest via guest cpuid.
- L1 guest pcommit is never intercepted by Xen.
Quoted 8 lines
I wish there was some watermarks like the PLE has.
My fear is that an unfriendly guest can issue sfence all day long flushing out other guests MMC queue (the writes followed by pcommits). Which means that an guest may have degraded performance as their memory writes are being flushed out immediately as if they were being written to UC instead of WB memory.
pcommit takes no parameter and it seems hard to solve this problem from hardware for now. And the current VMX does not provide mechanism to limit the commit rate of pcommit like PLE for pause.
Quoted 4 lines
In other words - the NVDIMM resource does not provide any resource isolation. However this may not be any different than what we had nowadays with CPU caches.
Does Xen have any mechanism to isolate multiple guests' operations on CPU caches?
Quoted 5 lines
Quoted 2 lines
- L1 hypervisor is allowed to intercept L2 guest pcommit.
clwb?
VMX is not capable to intercept clwb. Any reason to intercept it?
Quoted 48 lines
Quoted 46 lines
3.2 Address Mapping
3.2.1 My Design
The overview of this design is shown in the following figure.
Dom0 | DomU | | QEMU | +...+--------------------+...+-----+ | VA | | Label Storage Area | | buf | | +...+--------------------+...+-----+ | ^ ^ ^ | | | | | V | | | +-------+ +-------+ mmap(2) | | vACPI | | v_DSM | | | | +----+------------+ +-------+ +-------+ | | | SPA | | /dev/pmem0 | ^ ^ +------+ | | +----+------------+ --------|-----------|-----|------------|-- | ^ ^ | | | | | | | | +------+ +------------~-----~-------------+ | | | | | | XEN_DOMCTL_memory_mapping | | | +-----~--------------------------+ | | | | | | | +----+------------+ | Linux | | SPA | | /dev/pmem0 | | +------+ +------+ | | +----+------------+ | | ACPI | | _DSM | | | ^ | +------+ +------+ | | | | | | | | Dom0 Driver | hvmloader/xl | --------|----|-------------------|---------------------|----------|--------------- | +-------------------~---------------------~----------+ Xen | | | +------------------------~---------------------+ ---------------------------------|------------------------------------------------ +----------------+ | +-------------+ HW | NVDIMM | +-------------+Quoted 1 line
This design treats host NVDIMM devices as ordinary MMIO devices:
Quoted 8 lines
Nice.
But it also means you need Xen to 'share' the ranges of an MMIO device.
That is you may need dom0
_DSMmethod to access certain ranges (the AML code may need to poke there) - and the guest may want to access those as well.
Currently, we are going to support _DSM that queries supported _DSM commands and accesses vNVDIMM's label storage area. Both are emulated by QEMU and not applied to host NVDIMM.
Quoted 2 lines
And keep in mind that this NVDIMM management may not need to be always in initial domain.
I guess you mean it can be in a dedicated driver domain,
Quoted 2 lines
As in you could have NVDIMM device drivers that would carve out the ranges to guests.
but I don't get what you mean here. More hints?
[...]
Quoted 69 lines
Quoted 35 lines
3.2.2 Alternative Design
Jan Beulich's comments [7] on my question "why must pmem resource management and partition be done in hypervisor":
| Because that's where memory management belongs. And PMEM, | other than PBLK, is just another form of RAM. | ... | The main issue is that this would imo be a layering violationGeorge Dunlap's comments [8]:
| This is not the case for PMEM. The whole point of PMEM (correct me if
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ used as fungible ram| I'm wrong) is to be used for long-term storage that survives over | reboot. It matters very much that a guest be given the same PRAM | after the host is rebooted that it was given before. It doesn't make | any sense to manage it the way Xen currently manages RAM (i.e., that | you request a page and get whatever Xen happens to give you). | | So if Xen is going to use PMEM, it will have to invent an entirely new | interface for guests, and it will have to keep track of those | resources across host reboots. In other words, it will have to | duplicate all the work that Linux already does. What do we gain from | that duplication? Why not just leverage what's already implemented in | dom0? and [9]: | Oh, right -- yes, if the usage model of PRAM is just "cheap slow RAM", | then you're right -- it is just another form of RAM, that should be | treated no differently than say, lowmem: a fungible resource that can be | requested by setting a flag.However, pmem is used more as persistent storage than fungible ram, and my design is for the former usage. I would like to leave the detection, driver and partition (either through namespace or file systems) of NVDIMM in Dom0 Linux kernel.
Quoted 5 lines
I notice that current
XEN_DOMCTL_memory_mappingdoes not make santiy check for the physical address and size passed from caller (QEMU). Can QEMU be always trusted? If not, we would need to make Xen aware of the SPA range of pmem so that it can refuse map physical address in neither the normal ram nor pmem./me nods.
Quoted 27 lines
Instead of duplicating the detection code (parsing NFIT and evaluating
_FIT) in Dom0 Linux kernel, we decide to patch Dom0 Linux kernel to pass parameters of host pmem NVDIMM devices to Xen hypervisor:
(1) Add a global
struct rangesetpmem_rangeset
in Xen hypervisor to record all SPA ranges of detected pmem devices. Each range inpmem_rangesetcorresponds to a pmem device.(2) Add a hypercall
XEN_SYSCTL_add_pmem_range
(should it be a sysctl or a platform op?)
that receives a pair of parameters (addr: starting SPA of pmem region, len: size of pmem region) and add a range (addr, addr + len - 1) innvdimm_rangset.(3) Add a hypercall
XEN_DOMCTL_pmem_mapping
that takes the same parameters asXEN_DOMCTL_memory_mappingand maps a given host pmem range to guest. It checks whether the given host pmem range is in thepmem_rangesetbefore making the actual mapping.(4) Patch Linux NVDIMM driver to call
XEN_SYSCTL_add_pmem_rangewhenever it detects a pmem device.
Quoted 7 lines
Quoted 2 lines
(5) Patch QEMU to use
XEN_DOMCTL_pmem_mappingfor mapping host pmem devices.That is nice - as you can instrument this on existing hardware and create 'fake' starting SPA for real memory - which Xen may not see due to being booted with 'mem=X'.
'mem=X' only limits the maximum address of normal ram. NVDIMM or other MMIO devices are limited by it as well or not?
Thanks,
Haozhong
Quoted 20 lines
Quoted 1 line
Quoted 1 line · On 03.02.16 at 09:28, <[email protected]> wrote:
Quoted 6 lines · Konrad Rzeszutek Wilk
Quoted 5 lines
3.1 Guest clwb/clflushopt/pcommit Enabling
The instruction enabling is simple and we do the same work as in KVM/QEMU.
- All three instructions are exposed to guest via guest cpuid.
- L1 guest pcommit is never intercepted by Xen.Quoted 7 lines
I wish there was some watermarks like the PLE has.
My fear is that an unfriendly guest can issue sfence all day long flushing out other guests MMC queue (the writes followed by pcommits). Which means that an guest may have degraded performance as their memory writes are being flushed out immediately as if they were being written to UC instead of WB memory.
pcommit takes no parameter and it seems hard to solve this problem from hardware for now. And the current VMX does not provide mechanism to limit the commit rate of pcommit like PLE for pause.
Quoted 7 lines
Quoted 4 lines
In other words - the NVDIMM resource does not provide any resource isolation. However this may not be any different than what we had nowadays with CPU caches.
Does Xen have any mechanism to isolate multiple guests' operations on CPU caches?
No. All it does is disallow wbinvd for guests not controlling any actual hardware. Perhaps pcommit should at least be limited in a similar way?
Quoted 5 lines
Quoted 3 lines
Quoted 1 line
- L1 hypervisor is allowed to intercept L2 guest pcommit.
clwb?
VMX is not capable to intercept clwb. Any reason to intercept it?
I don't think so - otherwise normal memory writes might also need intercepting. Bus bandwidth simply is shared (and CLWB operates on a guest virtual address, so can only cause bus traffic for cache lines the guest has managed to dirty).
Jan
Quoted 25 lines · Jan Beulich
Quoted 25 lines
Quoted 1 line
Quoted 1 line · On 03.02.16 at 09:28, <[email protected]> wrote:
Quoted 6 lines · Konrad Rzeszutek Wilk
Quoted 5 lines
3.1 Guest clwb/clflushopt/pcommit Enabling
The instruction enabling is simple and we do the same work as in KVM/QEMU.
- All three instructions are exposed to guest via guest cpuid.
- L1 guest pcommit is never intercepted by Xen.Quoted 7 lines
I wish there was some watermarks like the PLE has.
My fear is that an unfriendly guest can issue sfence all day long flushing out other guests MMC queue (the writes followed by pcommits). Which means that an guest may have degraded performance as their memory writes are being flushed out immediately as if they were being written to UC instead of WB memory.
pcommit takes no parameter and it seems hard to solve this problem from hardware for now. And the current VMX does not provide mechanism to limit the commit rate of pcommit like PLE for pause.
Quoted 4 lines
In other words - the NVDIMM resource does not provide any resource isolation. However this may not be any different than what we had nowadays with CPU caches.
Quoted 7 lines
Quoted 2 lines
Does Xen have any mechanism to isolate multiple guests' operations on CPU caches?
No. All it does is disallow wbinvd for guests not controlling any actual hardware. Perhaps pcommit should at least be limited in a similar way?
But pcommit is a must that makes writes be persistent on pmem. I'll look at how guest wbinvd is limited in Xen. Any functions suggested, vmx_wbinvd_intercept()?
Thanks,
Haozhong
Quoted 13 lines
Quoted 5 lines
Quoted 3 lines
Quoted 1 line
- L1 hypervisor is allowed to intercept L2 guest pcommit.
clwb?
VMX is not capable to intercept clwb. Any reason to intercept it?
I don't think so - otherwise normal memory writes might also need intercepting. Bus bandwidth simply is shared (and CLWB operates on a guest virtual address, so can only cause bus traffic for cache lines the guest has managed to dirty).
Jan
Quoted 31 lines
Quoted 1 line
Quoted 1 line · On 03.02.16 at 13:22, <[email protected]> wrote:
Quoted 5 lines · Jan Beulich
Quoted 5 lines
Quoted 1 line
Quoted 1 line · On 03.02.16 at 09:28, <[email protected]> wrote:
Quoted 3 lines · Konrad Rzeszutek Wilk
Quoted 3 lines
3.1 Guest clwb/clflushopt/pcommit Enabling
The instruction enabling is simple and we do the same work as in
KVM/QEMU.
Quoted 23 lines
Quoted 22 lines
Quoted 10 lines
Quoted 2 lines
- All three instructions are exposed to guest via guest cpuid.
- L1 guest pcommit is never intercepted by Xen.I wish there was some watermarks like the PLE has.
My fear is that an unfriendly guest can issue sfence all day long flushing out other guests MMC queue (the writes followed by pcommits). Which means that an guest may have degraded performance as their memory writes are being flushed out immediately as if they were being written to UC instead of WB memory.
pcommit takes no parameter and it seems hard to solve this problem from hardware for now. And the current VMX does not provide mechanism to limit the commit rate of pcommit like PLE for pause.
Quoted 4 lines
In other words - the NVDIMM resource does not provide any resource isolation. However this may not be any different than what we had nowadays with CPU caches.
Does Xen have any mechanism to isolate multiple guests' operations on CPU caches?
Quoted 7 lines
Quoted 4 lines
No. All it does is disallow wbinvd for guests not controlling any actual hardware. Perhaps pcommit should at least be limited in a similar way?
But pcommit is a must that makes writes be persistent on pmem. I'll look at how guest wbinvd is limited in Xen.
But we could intercept it on guests _not_ supposed to use it, in order to simply drop in on the floor.
Quoted 1 line
Any functions suggested,
vmx_wbinvd_intercept()?
A good example, yes.
Jan
Quoted 36 lines · Jan Beulich
Quoted 36 lines
Quoted 1 line
Quoted 1 line · On 03.02.16 at 13:22, <[email protected]> wrote:
Quoted 5 lines · Jan Beulich
Quoted 5 lines
Quoted 1 line
Quoted 1 line · On 03.02.16 at 09:28, <[email protected]> wrote:
Quoted 3 lines · Konrad Rzeszutek Wilk
Quoted 3 lines
3.1 Guest clwb/clflushopt/pcommit Enabling
The instruction enabling is simple and we do the same work as in
KVM/QEMU.
Quoted 27 lines
Quoted 15 lines
Quoted 10 lines
Quoted 2 lines
- All three instructions are exposed to guest via guest cpuid.
- L1 guest pcommit is never intercepted by Xen.I wish there was some watermarks like the PLE has.
My fear is that an unfriendly guest can issue sfence all day long flushing out other guests MMC queue (the writes followed by pcommits). Which means that an guest may have degraded performance as their memory writes are being flushed out immediately as if they were being written to UC instead of WB memory.
pcommit takes no parameter and it seems hard to solve this problem from hardware for now. And the current VMX does not provide mechanism to limit the commit rate of pcommit like PLE for pause.
Quoted 7 lines
Quoted 4 lines
In other words - the NVDIMM resource does not provide any resource isolation. However this may not be any different than what we had nowadays with CPU caches.
Does Xen have any mechanism to isolate multiple guests' operations on CPU caches?
No. All it does is disallow wbinvd for guests not controlling any actual hardware. Perhaps pcommit should at least be limited in a similar way?
Quoted 6 lines
Quoted 2 lines
But pcommit is a must that makes writes be persistent on pmem. I'll look at how guest wbinvd is limited in Xen.
But we could intercept it on guests _not_ supposed to use it, in order to simply drop in on the floor.
Oh yes! We can drop pcommit from domains not having access to host NVDIMM, just like vmx_wbinvd_intercept() dropping wbinvd from domains not accessing host iomem and ioport.
Quoted 6 lines
Quoted 1 line
Any functions suggested,
vmx_wbinvd_intercept()?A good example, yes.
Jan
Thanks,
Haozhong
Quoted 8 lines · Jan Beulich
Quoted 7 lines
Quoted 5 lines
In other words - the NVDIMM resource does not provide any resource isolation. However this may not be any different than what we had nowadays with CPU caches.
Does Xen have any mechanism to isolate multiple guests' operations on CPU caches?
No.
PSR Cache Allocation is supported in Xen 4.6 on supporting hardware, so the administrator can partition guests if necessary.
~Andrew
Quoted 7 lines
Quoted 1 line
Quoted 1 line · On 03.02.16 at 15:30, <[email protected]> wrote:
Quoted 5 lines · Jan Beulich
Quoted 5 lines
Quoted 5 lines
In other words - the NVDIMM resource does not provide any resource isolation. However this may not be any different than what we had nowadays with CPU caches.
Quoted 6 lines
Quoted 3 lines
Quoted 2 lines
Does Xen have any mechanism to isolate multiple guests' operations on CPU caches?
No.
PSR Cache Allocation is supported in Xen 4.6 on supporting hardware, so the administrator can partition guests if necessary.
And if the hardware supports it (which for a while might be more the exception than the rule).
Jan
Quoted 5 lines · Konrad Rzeszutek Wilk
Quoted 1 line
3. Design of vNVDIMM in Xen
Thank you for this design!
Quoted 1 line
Quoted 9 lines
Quoted 5 lines
Similarly to that in KVM/QEMU, enabling vNVDIMM in Xen is composed of three parts:
(1) Guest clwb/clflushopt/pcommit enabling,
(2) Memory mapping, and
(3) Guest ACPI emulation... MCE? and vMCE?
NVDIMM can generate UCR errors like normal ram. Xen may handle them in a way similar to what mc_memerr_dhandler() does, with some differences in the data structure and the broken page offline parts:
Broken NVDIMM pages should be marked as "offlined" so that Xen hypervisor can refuse further requests that map them to DomU.
The real problem here is what data structure will be used to record information of NVDIMM pages. Because the size of NVDIMM is usually much larger than normal ram, using struct page_info for NVDIMM pages would occupy too much memory.
Alternatively, we may use a range set to represent NVDIMM pages:
struct nvdimm_pages
{
unsigned long mfn; /* starting MFN of a range of NVDIMM pages */
unsigned long gfn; /* starting GFN where this range is mapped,
initially INVALID_GFN */
unsigned long len; /* length of this range in bytes */
int broken; /* 0: initial value,
1: this range of NVDIMM pages are broken and offlined */
struct domain *d; /* NULL: initial value,
Not NULL: which domain this range is mapped to */
/*
* Every nvdimm_pages structure is linked in the global
* xen_nvdimm_pages_list.
*
* If it is mapped to a domain d, it will be also linked in
* d->arch.nvdimm_pages_list.
*/
struct list_head *domain_list;
struct list_head *global_list;
}
struct list_head xen_nvdimm_pages_list;
/* in asm-x86/domain.h */
struct arch_domain
{
...
struct list_head nvdimm_pages_list;
}(1) Initially, Xen hypervisor creates a nvdimm_pages structure for each pmem region (starting SPA and size reported by Dom0 NVDIMM driver) and links all nvdimm_pages structures in xen_nvdimm_pages_list.
(2) If Xen hypervisor is then requested to map a range of NVDIMM pages [start_mfn, end_mfn] to gfn of domain d, it will
(a) Check whether the GFN range [gfn, gfn + end_mfn - start_mfn + 1] of domain d has been occupied (e.g. by normal ram, I/O or other vNVDIMM).
(b) Search xen_nvdimm_pages_list for one or multiple nvdimm_pages that [start_mfn, end_mfn] can fit in.
If a nvdimm_pages structure is entirely covered by [start_mfn, end_mfn], then link that nvdimm_pages structure to d->arch.nvdimm_pages_list.
If only a portion of a nvdimm_pages structure is covered by [start_mfn, end_mfn], then split that nvdimm_pages structure into multiple ones (the one entirely covered and at most two not covered), link the covered one to d->arch.nvdimm_pages_list and all of them to xen_nvdimm_pages_list as well.
gfn and d fields of nvdimm_pages structures linked to d->arch.nvdimm_pages_list are also set accordingly.
(3) When a domain d is shutdown/destroyed, merge its nvdimm_pages
structures (i.e. those in d->arch.nvdimm_pages_list) in
xen_nvdimm_pages_list.(4) When a MCE for host NVDIMM SPA range [start_mfn, end_mfn] happens,
(a) search xen_nvdimm_pages_list for affected nvdimm_pages structures,
(b) for each affected nvdimm_pages, if it belongs to a domain d and its broken field is already set, the domain d will be shutdown to prevent malicious guest accessing broken page (similarly to what offline_page() does).
(c) for each affected nvdimm_pages, set its broken field to 1, and
(d) for each affected nvdimm_pages, inject to domain d a vMCE that covers its GFN range if that nvdimm_pages belongs to domain d.
Comments, pls.
Thanks,
Haozhong
Quoted 16 lines
Quoted 1 line
Quoted 1 line · On 15.02.16 at 09:43, <[email protected]> wrote:
Quoted 9 lines · Konrad Rzeszutek Wilk
Quoted 5 lines
Similarly to that in KVM/QEMU, enabling vNVDIMM in Xen is composed of three parts:
(1) Guest clwb/clflushopt/pcommit enabling,
(2) Memory mapping, and
(3) Guest ACPI emulation... MCE? and vMCE?
NVDIMM can generate UCR errors like normal ram. Xen may handle them in a way similar to what
mc_memerr_dhandler()does, with some differences in the data structure and the broken page offline parts:
Quoted 7 lines
Broken NVDIMM pages should be marked as "offlined" so that Xen hypervisor can refuse further requests that map them to DomU.
The real problem here is what data structure will be used to record information of NVDIMM pages. Because the size of NVDIMM is usually much larger than normal ram, using struct
page_infofor NVDIMM pages would occupy too much memory.
I don't see how your alternative below would be less memory
hungry: Since guests have at least partial control of their GFN space, a malicious guest could punch holes into the contiguous GFN range that you appear to be thinking about, thus causing arbitrary splitting of the control structure.
Also - see how you all of the sudden came to think of using struct page_info here (implying hypervisor control of these NVDIMM ranges)?
Quoted 9 lines
(4) When a MCE for host NVDIMM SPA range [
start_mfn,end_mfn] happens,
(a) searchxen_nvdimm_pages_listfor affectednvdimm_pagesstructures,
(b) for each affectednvdimm_pages, if it belongs to a domain d and its broken field is already set, the domain d will be shutdown to prevent malicious guest accessing broken page (similarly to whatoffline_page()does).
(c) for each affectednvdimm_pages, set its broken field to 1, and
(d) for each affectednvdimm_pages, inject to domain d a vMCE that covers its GFN range if thatnvdimm_pagesbelongs to domain d.
I don't see why you'd want to mark the entire range bad: All that's known to be broken is a single page. Hence this would be another source of splits of the proposed control structures.
Jan
Quoted 24 lines · Jan Beulich
Quoted 16 lines
Quoted 1 line
Quoted 1 line · On 15.02.16 at 09:43, <[email protected]> wrote:
Quoted 9 lines · Konrad Rzeszutek Wilk
Quoted 5 lines
Similarly to that in KVM/QEMU, enabling vNVDIMM in Xen is composed of three parts:
(1) Guest clwb/clflushopt/pcommit enabling,
(2) Memory mapping, and
(3) Guest ACPI emulation... MCE? and vMCE?
NVDIMM can generate UCR errors like normal ram. Xen may handle them in a way similar to what
mc_memerr_dhandler()does, with some differences in the data structure and the broken page offline parts:Quoted 7 lines
Broken NVDIMM pages should be marked as "offlined" so that Xen hypervisor can refuse further requests that map them to DomU.
The real problem here is what data structure will be used to record information of NVDIMM pages. Because the size of NVDIMM is usually much larger than normal ram, using struct
page_infofor NVDIMM pages would occupy too much memory.
Quoted 6 lines
I don't see how your alternative below would be less memory
hungry: Since guests have at least partial control of their GFN space, a malicious guest could punch holes into the contiguous GFN range that you appear to be thinking about, thus causing arbitrary splitting of the control structure.
QEMU would always use MFN above guest normal ram and I/O holes for vNVDIMM. It would attempt to search in that space for a contiguous range that is large enough for that that vNVDIMM devices. Is guest able to punch holes in such GFN space?
Quoted 14 lines
Also - see how you all of the sudden came to think of using struct
page_infohere (implying hypervisor control of these NVDIMM ranges)?Quoted 9 lines
(4) When a MCE for host NVDIMM SPA range [
start_mfn,end_mfn] happens,
(a) searchxen_nvdimm_pages_listfor affectednvdimm_pagesstructures,
(b) for each affectednvdimm_pages, if it belongs to a domain d and its broken field is already set, the domain d will be shutdown to prevent malicious guest accessing broken page (similarly to whatoffline_page()does).
(c) for each affectednvdimm_pages, set its broken field to 1, and
(d) for each affectednvdimm_pages, inject to domain d a vMCE that covers its GFN range if thatnvdimm_pagesbelongs to domain d.
Quoted 4 lines
I don't see why you'd want to mark the entire range bad: All that's known to be broken is a single page. Hence this would be another source of splits of the proposed control structures.
Oh yes, I should split the whole range here. Such kind of splits is caused by hardware errors. Unless the host NVDIMM is terribly broken, there should not be a large amount of splits.
Haozhong
Quoted 33 lines
Quoted 1 line
Quoted 1 line · On 17.02.16 at 10:01, <[email protected]> wrote:
Quoted 24 lines · Jan Beulich
Quoted 16 lines
Quoted 1 line
Quoted 1 line · On 15.02.16 at 09:43, <[email protected]> wrote:
Quoted 9 lines · Konrad Rzeszutek Wilk
Quoted 5 lines
Similarly to that in KVM/QEMU, enabling vNVDIMM in Xen is composed of three parts:
(1) Guest clwb/clflushopt/pcommit enabling,
(2) Memory mapping, and
(3) Guest ACPI emulation... MCE? and vMCE?
NVDIMM can generate UCR errors like normal ram. Xen may handle them in a way similar to what
mc_memerr_dhandler()does, with some differences in the data structure and the broken page offline parts:Quoted 7 lines
Broken NVDIMM pages should be marked as "offlined" so that Xen hypervisor can refuse further requests that map them to DomU.
The real problem here is what data structure will be used to record information of NVDIMM pages. Because the size of NVDIMM is usually much larger than normal ram, using struct
page_infofor NVDIMM pages would occupy too much memory.Quoted 6 lines
I don't see how your alternative below would be less memory
hungry: Since guests have at least partial control of their GFN space, a malicious guest could punch holes into the contiguous GFN range that you appear to be thinking about, thus causing arbitrary splitting of the control structure.
Quoted 4 lines
QEMU would always use MFN above guest normal ram and I/O holes for vNVDIMM. It would attempt to search in that space for a contiguous range that is large enough for that that vNVDIMM devices. Is guest able to punch holes in such GFN space?
See XENMAPSPACE_* and their uses.
Jan
Quoted 33 lines · Jan Beulich
Quoted 33 lines
Quoted 1 line
Quoted 1 line · On 17.02.16 at 10:01, <[email protected]> wrote:
Quoted 30 lines · Jan Beulich
Quoted 16 lines
Quoted 1 line
Quoted 1 line · On 15.02.16 at 09:43, <[email protected]> wrote:
Quoted 9 lines · Konrad Rzeszutek Wilk
Quoted 5 lines
Similarly to that in KVM/QEMU, enabling vNVDIMM in Xen is composed of three parts:
(1) Guest clwb/clflushopt/pcommit enabling,
(2) Memory mapping, and
(3) Guest ACPI emulation... MCE? and vMCE?
NVDIMM can generate UCR errors like normal ram. Xen may handle them in a way similar to what
mc_memerr_dhandler()does, with some differences in the data structure and the broken page offline parts:Quoted 7 lines
Broken NVDIMM pages should be marked as "offlined" so that Xen hypervisor can refuse further requests that map them to DomU.
The real problem here is what data structure will be used to record information of NVDIMM pages. Because the size of NVDIMM is usually much larger than normal ram, using struct
page_infofor NVDIMM pages would occupy too much memory.I don't see how your alternative below would be less memory
hungry: Since guests have at least partial control of their GFN space, a malicious guest could punch holes into the contiguous GFN range that you appear to be thinking about, thus causing arbitrary splitting of the control structure.
Quoted 7 lines
Quoted 4 lines
QEMU would always use MFN above guest normal ram and I/O holes for vNVDIMM. It would attempt to search in that space for a contiguous range that is large enough for that that vNVDIMM devices. Is guest able to punch holes in such GFN space?
See XENMAPSPACE_* and their uses.
I think we can add following restrictions to avoid uses of XENMAPSPACE_* punching holes in GFNs of vNVDIMM:
(1) For XENMAPSPACE_shared_info and _grant_table, never map idx in them to GFNs occupied by vNVDIMM.
(2) For XENMAPSPACE_gmfn, _gmfn_range and _gmfn_foreign,
(a) never map idx in them to GFNs occupied by vNVDIMM, and
(b) never map idx corresponding to GFNs occupied by vNVDIMM
Haozhong
Quoted 5 lines
Quoted 5 lines
Quoted 4 lines
QEMU would always use MFN above guest normal ram and I/O holes for vNVDIMM. It would attempt to search in that space for a contiguous range that is large enough for that that vNVDIMM devices. Is guest able to punch holes in such GFN space?
Quoted 8 lines
Quoted 2 lines
See XENMAPSPACE_* and their uses.
I think we can add following restrictions to avoid uses of XENMAPSPACE_* punching holes in GFNs of vNVDIMM:
(1) For
XENMAPSPACE_shared_infoand_grant_table, never map idx in them to GFNs occupied by vNVDIMM.
OK, that sounds correct.
Quoted 4 lines
(2) For
XENMAPSPACE_gmfn,_gmfn_rangeand_gmfn_foreign,
(a) never map idx in them to GFNs occupied by vNVDIMM, and
(b) never map idx corresponding to GFNs occupied by vNVDIMM
Would that mean that guest xen-blkback or xen-netback wouldn't be able to fetch data from the GFNs? As in, what if the HVM guest that has the NVDIMM also serves as a device domain - that is it has xen-blkback running to service other guests?
Quoted 3 lines
Haozhong
Quoted 16 lines · Konrad Rzeszutek Wilk
Quoted 5 lines
Quoted 5 lines
Quoted 4 lines
QEMU would always use MFN above guest normal ram and I/O holes for vNVDIMM. It would attempt to search in that space for a contiguous range that is large enough for that that vNVDIMM devices. Is guest able to punch holes in such GFN space?
Quoted 8 lines
Quoted 2 lines
See XENMAPSPACE_* and their uses.
I think we can add following restrictions to avoid uses of XENMAPSPACE_* punching holes in GFNs of vNVDIMM:
(1) For
XENMAPSPACE_shared_infoand_grant_table, never map idx in them to GFNs occupied by vNVDIMM.OK, that sounds correct.
Quoted 1 line
Quoted 9 lines
Quoted 3 lines
(2) For
XENMAPSPACE_gmfn,_gmfn_rangeand_gmfn_foreign,
(a) never map idx in them to GFNs occupied by vNVDIMM, and
(b) never map idx corresponding to GFNs occupied by vNVDIMMWould that mean that guest xen-blkback or xen-netback wouldn't be able to fetch data from the GFNs? As in, what if the HVM guest that has the NVDIMM also serves as a device domain - that is it has xen-blkback running to service other guests?
I'm not familiar with xen-blkback and xen-netback, so following statements maybe wrong.
In my understanding, xen-blkback/-netback in a device domain maps the pages from other domains into its own domain, and copies data between those pages and vNVDIMM. The access to vNVDIMM is performed by NVDIMM driver in device domain. In which steps of this procedure that xen-blkback/-netback needs to map into GFNs of vNVDIMM?
Thanks,
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Haozhong Zhang writes ("Re: [Xen-devel] [RFC Design Doc] Add vNVDIMM support for Xen"):
Quoted 11 lines · Konrad Rzeszutek Wilk
Quoted 9 lines
[someone:]
Quoted 3 lines
(2) For
XENMAPSPACE_gmfn,_gmfn_rangeand_gmfn_foreign,
(a) never map idx in them to GFNs occupied by vNVDIMM, and
(b) never map idx corresponding to GFNs occupied by vNVDIMMWould that mean that guest xen-blkback or xen-netback wouldn't be able to fetch data from the GFNs? As in, what if the HVM guest that has the NVDIMM also serves as a device domain - that is it has xen-blkback running to service other guests?
Quoted 8 lines
I'm not familiar with xen-blkback and xen-netback, so following statements maybe wrong.
In my understanding, xen-blkback/-netback in a device domain maps the pages from other domains into its own domain, and copies data between those pages and vNVDIMM. The access to vNVDIMM is performed by NVDIMM driver in device domain. In which steps of this procedure that xen-blkback/-netback needs to map into GFNs of vNVDIMM?
I think I agree with what you are saying. I don't understand exactly what you are proposing above in XENMAPSPACE_gmfn but I don't see how anything about this would interfere with blkback.
blkback when talking to an nvdimm will just go through the block layer front door, and do a copy, I presume.
I don't see how netback comes into it at all.
But maybe I am just confused or ignorant! Please do explain :-).
Thanks,
Ian.
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 21 lines · Ian Jackson
Haozhong Zhang writes ("Re: [Xen-devel] [RFC Design Doc] Add vNVDIMM support for Xen"):
Quoted 11 lines · Konrad Rzeszutek Wilk
Quoted 9 lines
[someone:]
Quoted 3 lines
(2) For
XENMAPSPACE_gmfn,_gmfn_rangeand_gmfn_foreign,
(a) never map idx in them to GFNs occupied by vNVDIMM, and
(b) never map idx corresponding to GFNs occupied by vNVDIMMWould that mean that guest xen-blkback or xen-netback wouldn't be able to fetch data from the GFNs? As in, what if the HVM guest that has the NVDIMM also serves as a device domain - that is it has xen-blkback running to service other guests?
Quoted 8 lines
I'm not familiar with xen-blkback and xen-netback, so following statements maybe wrong.
In my understanding, xen-blkback/-netback in a device domain maps the pages from other domains into its own domain, and copies data between those pages and vNVDIMM. The access to vNVDIMM is performed by NVDIMM driver in device domain. In which steps of this procedure that xen-blkback/-netback needs to map into GFNs of vNVDIMM?
Quoted 6 lines
I think I agree with what you are saying. I don't understand exactly what you are proposing above in
XENMAPSPACE_gmfnbut I don't see how anything about this would interfere with blkback.blkback when talking to an nvdimm will just go through the block layer front door, and do a copy, I presume.
I believe you are right. The block layer, and then the fs would copy in.
Quoted 4 lines
I don't see how netback comes into it at all.
But maybe I am just confused or ignorant! Please do explain :-).
s/back/frontend/
My fear was refcounting.
Specifically where we do not do copying. For example, you could be sending data from the NVDIMM GFNs (scp?) to some other location (another host?). It would go over the xen-netback (in the dom0)
- which would then grant map it (dom0 would).
In effect Xen there are two guests (dom0 and domU) pointing in the P2M to the same GPFN. And that would mean:
Quoted 1 line
Quoted 1 line
Quoted 1 line
Quoted 1 line
(b) never map idx corresponding to GFNs occupied by vNVDIMM
Granted the XENMAPSPACE_gmfn happens _before_ the grant mapping is done so perhaps this is not an issue?
The other situation I was envisioning - where the driver domain has the NVDIMM passed in, and as well SR-IOV network card and functions as an iSCSI target. That should work OK as we just need the IOMMU to have the NVDIMM GPFNs programmed in.
Quoted 3 lines
Thanks,
Ian.
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 35 lines · Konrad Rzeszutek Wilk
Quoted 21 lines · Ian Jackson
Haozhong Zhang writes ("Re: [Xen-devel] [RFC Design Doc] Add vNVDIMM support for Xen"):
Quoted 11 lines · Konrad Rzeszutek Wilk
Quoted 9 lines
[someone:]
Quoted 3 lines
(2) For
XENMAPSPACE_gmfn,_gmfn_rangeand_gmfn_foreign,
(a) never map idx in them to GFNs occupied by vNVDIMM, and
(b) never map idx corresponding to GFNs occupied by vNVDIMMWould that mean that guest xen-blkback or xen-netback wouldn't be able to fetch data from the GFNs? As in, what if the HVM guest that has the NVDIMM also serves as a device domain - that is it has xen-blkback running to service other guests?
Quoted 8 lines
I'm not familiar with xen-blkback and xen-netback, so following statements maybe wrong.
In my understanding, xen-blkback/-netback in a device domain maps the pages from other domains into its own domain, and copies data between those pages and vNVDIMM. The access to vNVDIMM is performed by NVDIMM driver in device domain. In which steps of this procedure that xen-blkback/-netback needs to map into GFNs of vNVDIMM?
Quoted 6 lines
I think I agree with what you are saying. I don't understand exactly what you are proposing above in
XENMAPSPACE_gmfnbut I don't see how anything about this would interfere with blkback.blkback when talking to an nvdimm will just go through the block layer front door, and do a copy, I presume.
I believe you are right. The block layer, and then the fs would copy in.
Quoted 4 lines
I don't see how netback comes into it at all.
But maybe I am just confused or ignorant! Please do explain :-).
Quoted 9 lines
s/back/frontend/
My fear was refcounting.
Specifically where we do not do copying. For example, you could be sending data from the NVDIMM GFNs (scp?) to some other location (another host?). It would go over the xen-netback (in the dom0)
- which would then grant map it (dom0 would).
Thanks for the explanation!
It means NVDIMM is very possibly mapped in page granularity, and hypervisor needs per-page data structures like page_info (rather than the range set style nvdimm_pages) to manage those mappings.
Then we will face the problem that the potentially huge number of per-page data structures may not fit in the normal ram. Linux kernel developers came across the same problem, and their solution is to reserve an area of NVDIMM and put the page structures in the reserved area (https://lwn.net/Articles/672457/). I think we may take the similar solution:
(1) Dom0 Linux kernel reserves an area on each NVDIMM for Xen usage (besides the one used by Linux kernel itself) and reports the address and size to Xen hypervisor.
Reasons to choose Linux kernel to make the reservation include:
(a) only Dom0 Linux kernel has the NVDIMM driver,
(b) make it flexible for Dom0 Linux kernel to handle all reservations (for itself and Xen).
(2) Then Xen hypervisor builds the page structures for NVDIMM pages and stores them in above reserved areas.
(3) The reserved area is used as volatile, i.e. above two steps must be done for every host boot.
Quoted 5 lines
In effect Xen there are two guests (dom0 and domU) pointing in the P2M to the same GPFN. And that would mean:
Quoted 1 line
Quoted 1 line
Quoted 1 line
Quoted 1 line
(b) never map idx corresponding to GFNs occupied by vNVDIMM
Quoted 8 lines
Granted the
XENMAPSPACE_gmfnhappens _before_ the grant mapping is done so perhaps this is not an issue?The other situation I was envisioning - where the driver domain has the NVDIMM passed in, and as well SR-IOV network card and functions as an iSCSI target. That should work OK as we just need the IOMMU to have the NVDIMM GPFNs programmed in.
For this IOMMU usage example and above granted pages example, there remains one question: who is responsible to perform NVDIMM flush (clwb/clflushopt/pcommit)?
For the granted page example, if a NVDIMM page is granted to xen-netback, does the hypervisor need to tell xen-netback it's a NVDIMM page so that xen-netback can perform proper flush when it writes to that page? Or we may keep the NVDIMM transparent to xen-netback, and let Xen perform the flush when xen-netback gives up the granted NVDIMM page?
For the IOMMU example, my understanding is that there is a piece of software in the driver domain that handles SCSI commands received from network card and drives the network card to read/write certain areas of NVDIMM. Then that software should be aware of the existence of NVDIMM and perform the flush properly. Is that right?
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 15 lines
Quoted 1 line
Quoted 1 line · On 02.03.16 at 08:14, <[email protected]> wrote:
It means NVDIMM is very possibly mapped in page granularity, and hypervisor needs per-page data structures like
page_info(rather than the range set stylenvdimm_pages) to manage those mappings.Then we will face the problem that the potentially huge number of per-page data structures may not fit in the normal ram. Linux kernel developers came across the same problem, and their solution is to reserve an area of NVDIMM and put the page structures in the reserved area (https://lwn.net/Articles/672457/). I think we may take the similar solution:
(1) Dom0 Linux kernel reserves an area on each NVDIMM for Xen usage (besides the one used by Linux kernel itself) and reports the address and size to Xen hypervisor.
Quoted 7 lines
Reasons to choose Linux kernel to make the reservation include:
(a) only Dom0 Linux kernel has the NVDIMM driver,
(b) make it flexible for Dom0 Linux kernel to handle all reservations (for itself and Xen).(2) Then Xen hypervisor builds the page structures for NVDIMM pages and stores them in above reserved areas.
Another argument against this being primarily Dom0-managed, I would say. Furthermore - why would Dom0 waste space creating per-page control structures for regions which are meant to be handed to guests anyway?
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 20 lines · Jan Beulich
Quoted 20 lines
Quoted 1 line
Quoted 1 line · On 02.03.16 at 08:14, <[email protected]> wrote:
It means NVDIMM is very possibly mapped in page granularity, and hypervisor needs per-page data structures like
page_info(rather than the range set stylenvdimm_pages) to manage those mappings.Then we will face the problem that the potentially huge number of per-page data structures may not fit in the normal ram. Linux kernel developers came across the same problem, and their solution is to reserve an area of NVDIMM and put the page structures in the reserved area (https://lwn.net/Articles/672457/). I think we may take the similar solution:
(1) Dom0 Linux kernel reserves an area on each NVDIMM for Xen usage (besides the one used by Linux kernel itself) and reports the address and size to Xen hypervisor.Reasons to choose Linux kernel to make the reservation include:
(a) only Dom0 Linux kernel has the NVDIMM driver,
(b) make it flexible for Dom0 Linux kernel to handle all reservations (for itself and Xen).
Quoted 5 lines
Quoted 2 lines
(2) Then Xen hypervisor builds the page structures for NVDIMM pages and stores them in above reserved areas.
Another argument against this being primarily Dom0-managed, I would say.
Yes, Xen should, at least, manage all address mappings for NVDIMM. Dom0 Linux and QEMU then provide a user-friendly interface to configure NVDIMM and vNVDIMM: like providing files (instead of address) as the abstract of SPA ranges in/of NVDIMM.
Quoted 4 lines
Furthermore - why would Dom0 waste space
creating per-page control structures for regions which are meant to be handed to guests anyway?
I found my description was not accurate after consulting with our driver developers. By default the linux kernel does not create page structures for NVDIMM which is called by kernel the "raw mode". We could enforce the Dom0 kernel to pin NVDIMM in "raw mode" so as to avoid waste.
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 24 lines · Haozhong Zhang
Quoted 23 lines · Jan Beulich
Quoted 22 lines
Quoted 1 line
Quoted 1 line · On 02.03.16 at 08:14, <[email protected]> wrote:
It means NVDIMM is very possibly mapped in page granularity, and hypervisor needs per-page data structures like
page_info(rather than the range set stylenvdimm_pages) to manage those mappings.Then we will face the problem that the potentially huge number of per-page data structures may not fit in the normal ram. Linux kernel developers came across the same problem, and their solution is to reserve an area of NVDIMM and put the page structures in the reserved area (https://lwn.net/Articles/672457/). I think we may take the similar solution:
(1) Dom0 Linux kernel reserves an area on each NVDIMM for Xen usage (besides the one used by Linux kernel itself) and reports the address and size to Xen hypervisor.Reasons to choose Linux kernel to make the reservation include:
(a) only Dom0 Linux kernel has the NVDIMM driver,
(b) make it flexible for Dom0 Linux kernel to handle all reservations (for itself and Xen).(2) Then Xen hypervisor builds the page structures for NVDIMM pages and stores them in above reserved areas.
[...]
Quoted 10 lines
Quoted 4 lines
Furthermore - why would Dom0 waste space
creating per-page control structures for regions which are meant to be handed to guests anyway?I found my description was not accurate after consulting with our driver developers. By default the linux kernel does not create page structures for NVDIMM which is called by kernel the "raw mode". We could enforce the Dom0 kernel to pin NVDIMM in "raw mode" so as to avoid waste.
More thoughts on reserving NVDIMM space for per-page structures
Currently, a per-page struct for managing mapping of NVDIMM pages may include following fields:
struct nvdimm_page
{
uint64_t mfn; /* MFN of SPA of this NVDIMM page */
uint64_t gfn; /* GFN where this NVDIMM page is mapped */
domid_t domain_id; /* which domain is this NVDIMM page mapped to */
int is_broken; /* Is this NVDIMM page broken? (for MCE) */}
Its size is 24 bytes (or 22 bytes if packed). For a 2 TB NVDIMM, nvdimm_page structures would occupy 12 GB space, which is too hard to fit in the normal ram on a small memory host. However, for smaller NVDIMMs and/or hosts with large ram, those structures may still be able to fit in the normal ram. In the latter circumstance, nvdimm_page structures are stored in the normal ram, so they can be accessed more quickly.
So we may add a boot parameter for Xen to allow users to configure which place, the normal ram or nvdimm, are used to store those structures. For the config of using normal ram, Xen could manage nvdimm_page structures more quickly (and hence start a domain with NVDIMM more quickly), but leaves less normal ram for VMs. For the config of using nvdimm, Xen would take more time to mange nvdimm_page structures, but leaves more normal ram for VMs.
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 14 lines
Quoted 1 line
Quoted 1 line · On 08.03.16 at 10:15, <[email protected]> wrote:
More thoughts on reserving NVDIMM space for per-page structures
Currently, a per-page struct for managing mapping of NVDIMM pages may include following fields:
struct
nvdimm_page
{uint64_t mfn; /* MFN of SPA of this NVDIMM page */ uint64_t gfn; /* GFN where this NVDIMM page is mapped */ domid_t domain_id; /* which domain is this NVDIMM page mapped to */ int is_broken; /* Is this NVDIMM page broken? (for MCE) */}
Quoted 7 lines
Its size is 24 bytes (or 22 bytes if packed). For a 2 TB NVDIMM,
nvdimm_pagestructures would occupy 12 GB space, which is too hard to fit in the normal ram on a small memory host. However, for smaller NVDIMMs and/or hosts with large ram, those structures may still be able to fit in the normal ram. In the latter circumstance,nvdimm_pagestructures are stored in the normal ram, so they can be accessed more quickly.
Not sure how you came to the above structure - it's the first time I see it, yet figuring out what information it needs to hold is what this design process should be about. For example, I don't see why it would need to duplicate M2P / P2M information. Nor do I see why per-page data needs to hold the address of a page (struct page_info also doesn't). And whether storing a domain ID (rather than a pointer to struct domain, as in struct page_info) is the correct think is also to be determined (rather than just stated).
Otoh you make no provisions at all for any kind of ref counting. What if a guest wants to put page tables into NVDIMM space?
Since all of your calculations are based upon that fixed assumption on the structure layout, I'm afraid they're not very meaningful without first settling on what data needs tracking in the first place.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 31 lines · Jan Beulich
Quoted 14 lines
Quoted 1 line
Quoted 1 line · On 08.03.16 at 10:15, <[email protected]> wrote:
More thoughts on reserving NVDIMM space for per-page structures
Currently, a per-page struct for managing mapping of NVDIMM pages may include following fields:
struct
nvdimm_page
{uint64_t mfn; /* MFN of SPA of this NVDIMM page */ uint64_t gfn; /* GFN where this NVDIMM page is mapped */ domid_t domain_id; /* which domain is this NVDIMM page mapped to */ int is_broken; /* Is this NVDIMM page broken? (for MCE) */}
Quoted 7 lines
Its size is 24 bytes (or 22 bytes if packed). For a 2 TB NVDIMM,
nvdimm_pagestructures would occupy 12 GB space, which is too hard to fit in the normal ram on a small memory host. However, for smaller NVDIMMs and/or hosts with large ram, those structures may still be able to fit in the normal ram. In the latter circumstance,nvdimm_pagestructures are stored in the normal ram, so they can be accessed more quickly.Not sure how you came to the above structure - it's the first time I see it, yet figuring out what information it needs to hold is what this design process should be about. For example, I don't see why it would need to duplicate M2P / P2M information. Nor do I see why per-page data needs to hold the address of a page (struct
page_infoalso doesn't). And whether storing a domain ID (rather than a pointer to struct domain, as in structpage_info) is the correct think is also to be determined (rather than just stated).
Quoted 9 lines
Otoh you make no provisions at all for any kind of ref counting. What if a guest wants to put page tables into NVDIMM space?
Since all of your calculations are based upon that fixed assumption on the structure layout, I'm afraid they're not very meaningful without first settling on what data needs tracking in the first place.
Jan
I should reexplain the choice of data structures and where to put them.
For handling MCE for NVDIMM, we need to track following data:
(1) SPA ranges of host NVDIMMs (one range per pmem interleave set), which are used to check whether a MCE is for NVDIMM.
(2) GFN to which a NVDIMM page is mapped, which is used to determine the address put in vMCE.
(3) the domain to which a NVDIMM page is mapped, which is used to determine whether a vMCE needs to be injected and where it will be injected.
(4) a flag to mark whether a NVDIMM page is broken, which is used to avoid mapping broken page to guests.
For granting NVDIMM pages (e.g. xen-blkback/netback),
(5) a reference counter is needed for each NVDIMM page
Above data can be organized as below:
* For (1) SPA ranges, we can record them in a global data structure, e.g. a list
struct list_head nvdimm_iset_list;
struct nvdimm_iset
{
uint64_t base; /* starting SPA of this interleave set */
uint64_t size; /* size of this interleave set */
struct nvdimm_page *pages;/* information for individual pages in this interleave set */
struct list_head list;
};* For (2) GFN, an intuitive place to get this information is from M2P table machine_to_phys_mapping[]. However, the address of NVDIMM is not required to be contiguous with normal ram, so, if NVDIMM starts from an address that is much higher than the end address of normal ram, it may result in a M2P table that maybe too large to fit in the normal ram. Therefore, we choose to not put GFNs of NVDIMM in M2P table.
Another possible solution is to extend page_info to include GFN for NVDIMM and use frame_table. A benefit of this solution is that other data (3)-(5) can be got from page_info as well. However, due to the same reason for machine_to_phys_mapping[] and the concern that the large number of page_info structures required for large NVDIMMs may consume lots of ram, page_info and frame_table seems not a good place either.
* At the end, we choose to introduce a new data structure for above per-page data (2)-(5)
struct nvdimm_page
{
struct domain *domain; /* for (3) */
uint64_t gfn; /* for (2) */
unsigned long count_info; /* for (4) and (5), same as page_info->count_info */
/* other fields if needed, e.g. lock */
}(MFN is not needed indeed)
On each NVDIMM interleave set, we could reserve an area to place an array of nvdimm_page structures for pages in that interleave set. In addition, the corresponding global nvdimm_iset structure is set to point to this array via its 'pages' field.
* One disadvantage of above solution is that accessing NVDIMM is slower than normal ram, so some usage scenarios that requires frequently accesses to nvdimm_page structures may suffer poor performance. Therefore, we may add a boot parameter to allow users to choose normal ram for above nvdimm_page arrays if their hosts have plenty ram.
One thing I have no idea is what percentage of ram used/reserved by Xen itself is considered as acceptable. If it exists and a boot parameter is given, we could let Xen choose the faster ram when the percentage has not been reached.
Any comments?
Thanks,
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 71 lines
Quoted 1 line
Quoted 1 line · On 09.03.16 at 13:22, <[email protected]> wrote:
Quoted 31 lines · Jan Beulich
Quoted 14 lines
Quoted 1 line
Quoted 1 line · On 08.03.16 at 10:15, <[email protected]> wrote:
More thoughts on reserving NVDIMM space for per-page structures
Currently, a per-page struct for managing mapping of NVDIMM pages may include following fields:
struct
nvdimm_page
{uint64_t mfn; /* MFN of SPA of this NVDIMM page */ uint64_t gfn; /* GFN where this NVDIMM page is mapped */ domid_t domain_id; /* which domain is this NVDIMM page mapped to */ int is_broken; /* Is this NVDIMM page broken? (for MCE) */}
Quoted 7 lines
Its size is 24 bytes (or 22 bytes if packed). For a 2 TB NVDIMM,
nvdimm_pagestructures would occupy 12 GB space, which is too hard to fit in the normal ram on a small memory host. However, for smaller NVDIMMs and/or hosts with large ram, those structures may still be able to fit in the normal ram. In the latter circumstance,nvdimm_pagestructures are stored in the normal ram, so they can be accessed more quickly.Not sure how you came to the above structure - it's the first time I see it, yet figuring out what information it needs to hold is what this design process should be about. For example, I don't see why it would need to duplicate M2P / P2M information. Nor do I see why per-page data needs to hold the address of a page (struct
page_infoalso doesn't). And whether storing a domain ID (rather than a pointer to struct domain, as in structpage_info) is the correct think is also to be determined (rather than just stated).Quoted 6 lines
Otoh you make no provisions at all for any kind of ref counting. What if a guest wants to put page tables into NVDIMM space?
Since all of your calculations are based upon that fixed assumption on the structure layout, I'm afraid they're not very meaningful without first settling on what data needs tracking in the first place.
I should reexplain the choice of data structures and where to put them.
For handling MCE for NVDIMM, we need to track following data:
(1) SPA ranges of host NVDIMMs (one range per pmem interleave set), which are used to check whether a MCE is for NVDIMM.
(2) GFN to which a NVDIMM page is mapped, which is used to determine the address put in vMCE.
(3) the domain to which a NVDIMM page is mapped, which is used to determine whether a vMCE needs to be injected and where it will be injected.
(4) a flag to mark whether a NVDIMM page is broken, which is used to avoid mapping broken page to guests.For granting NVDIMM pages (e.g. xen-blkback/netback),
(5) a reference counter is needed for each NVDIMM pageAbove data can be organized as below:
* For (1) SPA ranges, we can record them in a global data structure, e.g. a list
struct list_head nvdimm_iset_list; struct nvdimm_iset { uint64_t base; /* starting SPA of this interleave set */ uint64_t size; /* size of this interleave set */ struct nvdimm_page *pages;/* information for individual pages in this interleave set */ struct list_head list; };
Quoted 7 lines
* For (2) GFN, an intuitive place to get this information is from M2P table machine_to_phys_mapping[]. However, the address of NVDIMM is not required to be contiguous with normal ram, so, if NVDIMM starts from an address that is much higher than the end address of normal ram, it may result in a M2P table that maybe too large to fit in the normal ram. Therefore, we choose to not put GFNs of NVDIMM in M2P table.
Any page that _may_ be used by a guest as normal RAM page must have its mach->phys translation entered in the M2P. That's because a r/o variant of that table is part of the hypervisor ABI for PV guests. Size considerations simply don't apply here - the table may be sparse (guests are required to deal with accesses potentially faulting), and the 256Gb of virtual address space set aside for it cover all memory up to the 47-bit boundary (there's room for doubling this). Memory at addresses with bit 47 (or higher) set would need a complete overhaul of that mechanism, and whatever new mechanism we may pick would mean old guests won#t be able to benefit.
Quoted 7 lines
Another possible solution is to extend
page_infoto include GFN for NVDIMM and useframe_table. A benefit of this solution is that other data (3)-(5) can be got frompage_infoas well. However, due to the same reason for machine_to_phys_mapping[] and the concern that the large number ofpage_infostructures required for large NVDIMMs may consume lots of ram,page_infoandframe_tableseems not a good place either.
For this particular item struct page_info is the wrong place anyway, due to what I've said above. Also extension suggestions of struct page_info are quite problematic, as any such implies a measurable increase on the memory overhead the hypervisor incurs. Plus the structure right now is (with the exception of the bigmem configuration) a carefully arranged for power of two in size.
Quoted 10 lines
* At the end, we choose to introduce a new data structure for above per-page data (2)-(5)
struct nvdimm_page { struct domain *domain; /* for (3) */ uint64_t gfn; /* for (2) */ unsigned long count_info; /* for (4) and (5), same as page_info->count_info */ /* other fields if needed, e.g. lock */ }
So that again leaves unaddressed the question of what you imply to do when a guest elects to use such a page as page table. I'm afraid any attempt of yours to invent something that is not struct page_info will not be suitable for all possible needs.
Quoted 4 lines
On each NVDIMM interleave set, we could reserve an area to place an array of
nvdimm_pagestructures for pages in that interleave set. In addition, the corresponding globalnvdimm_isetstructure is set to point to this array via its 'pages' field.
And I see no problem doing exactly that, just for an array of struct page_info.
Quoted 4 lines
One thing I have no idea is what percentage of ram used/reserved by Xen itself is considered as acceptable. If it exists and a boot parameter is given, we could let Xen choose the faster ram when the percentage has not been reached.
I think a conservative default would be to always place the control structures in NVDIMM space, unless requested to be put in RAM via command line option.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 3 lines · Jan Beulich
Quoted 3 lines
Quoted 1 line
Quoted 1 line · On 09.03.16 at 13:22, <[email protected]> wrote:
Quoted 1 line · Jan Beulich
Quoted 1 line
Quoted 1 line
Quoted 1 line · On 08.03.16 at 10:15, <[email protected]> wrote:
[...]
Quoted 39 lines
Quoted 31 lines
I should reexplain the choice of data structures and where to put them.
For handling MCE for NVDIMM, we need to track following data:
(1) SPA ranges of host NVDIMMs (one range per pmem interleave set), which are used to check whether a MCE is for NVDIMM.
(2) GFN to which a NVDIMM page is mapped, which is used to determine the address put in vMCE.
(3) the domain to which a NVDIMM page is mapped, which is used to determine whether a vMCE needs to be injected and where it will be injected.
(4) a flag to mark whether a NVDIMM page is broken, which is used to avoid mapping broken page to guests.For granting NVDIMM pages (e.g. xen-blkback/netback),
(5) a reference counter is needed for each NVDIMM pageAbove data can be organized as below:
* For (1) SPA ranges, we can record them in a global data structure, e.g. a list
struct list_head nvdimm_iset_list; struct nvdimm_iset { uint64_t base; /* starting SPA of this interleave set */ uint64_t size; /* size of this interleave set */ struct nvdimm_page *pages;/* information for individual pages in this interleave set */ struct list_head list; };Quoted 7 lines
* For (2) GFN, an intuitive place to get this information is from M2P table machine_to_phys_mapping[]. However, the address of NVDIMM is not required to be contiguous with normal ram, so, if NVDIMM starts from an address that is much higher than the end address of normal ram, it may result in a M2P table that maybe too large to fit in the normal ram. Therefore, we choose to not put GFNs of NVDIMM in M2P table.
Quoted 12 lines
Any page that _may_ be used by a guest as normal RAM page must have its
mach->phystranslation entered in the M2P. That's because a r/o variant of that table is part of the hypervisor ABI for PV guests. Size considerations simply don't apply here - the table may be sparse (guests are required to deal with accesses potentially faulting), and the 256Gb of virtual address space set aside for it cover all memory up to the 47-bit boundary (there's room for doubling this). Memory at addresses with bit 47 (or higher) set would need a complete overhaul of that mechanism, and whatever new mechanism we may pick would mean old guests won#t be able to benefit.
OK, then we can use M2P to get PFNs of NVDIMM pages. And ...
Quoted 27 lines
Quoted 7 lines
Another possible solution is to extend
page_infoto include GFN for NVDIMM and useframe_table. A benefit of this solution is that other data (3)-(5) can be got frompage_infoas well. However, due to the same reason for machine_to_phys_mapping[] and the concern that the large number ofpage_infostructures required for large NVDIMMs may consume lots of ram,page_infoandframe_tableseems not a good place either.For this particular item struct
page_infois the wrong place anyway, due to what I've said above. Also extension suggestions of structpage_infoare quite problematic, as any such implies a measurable increase on the memory overhead the hypervisor incurs. Plus the structure right now is (with the exception of the bigmem configuration) a carefully arranged for power of two in size.Quoted 10 lines
* At the end, we choose to introduce a new data structure for above per-page data (2)-(5)
struct nvdimm_page { struct domain *domain; /* for (3) */ uint64_t gfn; /* for (2) */ unsigned long count_info; /* for (4) and (5), same as page_info->count_info */ /* other fields if needed, e.g. lock */ }
Quoted 5 lines
So that again leaves unaddressed the question of what you imply to do when a guest elects to use such a page as page table. I'm afraid any attempt of yours to invent something that is not struct
page_infowill not be suitable for all possible needs.
... we can use page_info struct rather than nvdimm_page struct for NVDIMM pages and can be able to benefit from whatever have been done with page_info.
Quoted 8 lines
Quoted 4 lines
On each NVDIMM interleave set, we could reserve an area to place an array of
nvdimm_pagestructures for pages in that interleave set. In addition, the corresponding globalnvdimm_isetstructure is set to point to this array via its 'pages' field.And I see no problem doing exactly that, just for an array of struct
page_info.
Yes, page_info arrays.
Because page_info structs for NVDIMM may be put in NVDIMM, existing code that gets page_info from frame_table needs to be adjusted for NVDIMM pages to use nvdimm_iset structs instead, including __mfn_to_page, __page_to_mfn, page_to_spage, spage_to_page, page_to_pdx, pdx_to_page, etc.
Quoted 9 lines
Quoted 4 lines
One thing I have no idea is what percentage of ram used/reserved by Xen itself is considered as acceptable. If it exists and a boot parameter is given, we could let Xen choose the faster ram when the percentage has not been reached.
I think a conservative default would be to always place the control structures in NVDIMM space, unless requested to be put in RAM via command line option.
For the first version, I plan to implement above that puts all page_info structs for NVDIMM either completely in NVDIMM or completely in normal ram. In the future, we may introduce some software cache mechanism that caches the most frequently used NVDIMM page_info in the normal ram.
Thanks,
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Jan Beulich writes ("Re: [Xen-devel] [RFC Design Doc] Add vNVDIMM support for Xen"):
Quoted 4 lines
So that again leaves unaddressed the question of what you imply to do when a guest elects to use such a page as page table. I'm afraid any attempt of yours to invent something that is not struct
page_infowill not be suitable for all possible needs.
It is not clear to me whether this is a realistic thing for a guest to want to do. Haozhong, maybe you want to consider this aspect.
If you can come up with an argument why it is OK to simply not permit this, then maybe the recordkeeping requirements can be relaxed ?
Ian.
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 9 lines · Ian Jackson
Jan Beulich writes ("Re: [Xen-devel] [RFC Design Doc] Add vNVDIMM support for Xen"):
Quoted 4 lines
So that again leaves unaddressed the question of what you imply to do when a guest elects to use such a page as page table. I'm afraid any attempt of yours to invent something that is not struct
page_infowill not be suitable for all possible needs.It is not clear to me whether this is a realistic thing for a guest to want to do. Haozhong, maybe you want to consider this aspect.
For HVM guests, it's themselves responsibility to not grant (e.g. in xen-blk/net drivers) a vNVDIMM page containing page tables to others.
For PV guests (if we add vNVDIMM support for them in future), as I'm going to use page_info struct for it, I suppose the current mechanism in Xen can handle this case. I'm not familiar with PV memory management and have to admit I didn't find the exact code that handles the case that a memory page contains the guest page table. Jan, could you indicate the code that I can follow to understand what xen does in this case?
Thanks,
Haozhong
Quoted 4 lines
If you can come up with an argument why it is OK to simply not permit this, then maybe the recordkeeping requirements can be relaxed ?
Ian.
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 16 lines
Quoted 1 line
Quoted 1 line · On 17.03.16 at 14:37, <[email protected]> wrote:
Quoted 1 line · Ian Jackson
Jan Beulich writes ("Re: [Xen-devel] [RFC Design Doc] Add vNVDIMM support for
Xen"):
Quoted 8 lines
Quoted 4 lines
So that again leaves unaddressed the question of what you imply to do when a guest elects to use such a page as page table. I'm afraid any attempt of yours to invent something that is not struct
page_infowill not be suitable for all possible needs.It is not clear to me whether this is a realistic thing for a guest to want to do. Haozhong, maybe you want to consider this aspect.
For HVM guests, it's themselves responsibility to not grant (e.g. in xen-blk/net drivers) a vNVDIMM page containing page tables to others.
Quoted 7 lines
For PV guests (if we add vNVDIMM support for them in future), as I'm going to use
page_infostruct for it, I suppose the current mechanism in Xen can handle this case. I'm not familiar with PV memory management and have to admit I didn't find the exact code that handles the case that a memory page contains the guest page table. Jan, could you indicate the code that I can follow to understand what xen does in this case?
xen/arch/x86/mm.c has functions like __get_page_type(), alloc_page_type(), alloc_l[1234]_table(), and mod_l[1234]_entry() which all participate in this.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 24 lines · Jan Beulich
Quoted 16 lines
Quoted 1 line
Quoted 1 line · On 17.03.16 at 14:37, <[email protected]> wrote:
Quoted 1 line · Ian Jackson
Jan Beulich writes ("Re: [Xen-devel] [RFC Design Doc] Add vNVDIMM support for
Xen"):
Quoted 8 lines
Quoted 4 lines
So that again leaves unaddressed the question of what you imply to do when a guest elects to use such a page as page table. I'm afraid any attempt of yours to invent something that is not struct
page_infowill not be suitable for all possible needs.It is not clear to me whether this is a realistic thing for a guest to want to do. Haozhong, maybe you want to consider this aspect.
For HVM guests, it's themselves responsibility to not grant (e.g. in xen-blk/net drivers) a vNVDIMM page containing page tables to others.
Quoted 7 lines
For PV guests (if we add vNVDIMM support for them in future), as I'm going to use
page_infostruct for it, I suppose the current mechanism in Xen can handle this case. I'm not familiar with PV memory management and have to admit I didn't find the exact code that handles the case that a memory page contains the guest page table. Jan, could you indicate the code that I can follow to understand what xen does in this case?
Quoted 4 lines
xen/arch/x86/mm.chas functions like__get_page_type(),alloc_page_type(), alloc_l[1234]_table(), and mod_l[1234]_entry() which all participate in this.
Thanks!
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 3 lines · Haozhong Zhang
For PV guests (if we add vNVDIMM support for them in future), as I'm going to use
page_infostruct for it, I suppose the current mechanism in Xen can handle this case. I'm not familiar with PV memory management
The below web may be helpful:
http://wiki.xen.org/wiki/X86_Paravirtualised_Memory_Management
:)
Quan
Quoted 4 lines
and have to admit I
didn't find the exact code that handles the case that a memory page contains the guest page table. Jan, could you indicate the code that I can follow to understand what xen does in this case?
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 11 lines · Quan
Quoted 3 lines · Haozhong Zhang
For PV guests (if we add vNVDIMM support for them in future), as I'm going to use
page_infostruct for it, I suppose the current mechanism in Xen can handle this case. I'm not familiar with PV memory managementThe below web may be helpful:
http://wiki.xen.org/wiki/X86_Paravirtualised_Memory_Management:)
Quan
Thanks!
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 46 lines · Haozhong Zhang
Quoted 35 lines · Konrad Rzeszutek Wilk
Quoted 21 lines · Ian Jackson
Haozhong Zhang writes ("Re: [Xen-devel] [RFC Design Doc] Add vNVDIMM support for Xen"):
Quoted 11 lines · Konrad Rzeszutek Wilk
Quoted 9 lines
[someone:]
Quoted 3 lines
(2) For
XENMAPSPACE_gmfn,_gmfn_rangeand_gmfn_foreign,
(a) never map idx in them to GFNs occupied by vNVDIMM, and
(b) never map idx corresponding to GFNs occupied by vNVDIMMWould that mean that guest xen-blkback or xen-netback wouldn't be able to fetch data from the GFNs? As in, what if the HVM guest that has the NVDIMM also serves as a device domain - that is it has xen-blkback running to service other guests?
Quoted 8 lines
I'm not familiar with xen-blkback and xen-netback, so following statements maybe wrong.
In my understanding, xen-blkback/-netback in a device domain maps the pages from other domains into its own domain, and copies data between those pages and vNVDIMM. The access to vNVDIMM is performed by NVDIMM driver in device domain. In which steps of this procedure that xen-blkback/-netback needs to map into GFNs of vNVDIMM?
Quoted 6 lines
I think I agree with what you are saying. I don't understand exactly what you are proposing above in
XENMAPSPACE_gmfnbut I don't see how anything about this would interfere with blkback.blkback when talking to an nvdimm will just go through the block layer front door, and do a copy, I presume.
I believe you are right. The block layer, and then the fs would copy in.
Quoted 4 lines
I don't see how netback comes into it at all.
But maybe I am just confused or ignorant! Please do explain :-).
Quoted 9 lines
s/back/frontend/
My fear was refcounting.
Specifically where we do not do copying. For example, you could be sending data from the NVDIMM GFNs (scp?) to some other location (another host?). It would go over the xen-netback (in the dom0)
- which would then grant map it (dom0 would).
Quoted 5 lines
Thanks for the explanation!
It means NVDIMM is very possibly mapped in page granularity, and hypervisor needs per-page data structures like
page_info(rather than the range set stylenvdimm_pages) to manage those mappings.
I do not know. I figured you need some accounting in the hypervisor as the pages can be grant mapped but I don't know the intricate details of the P2M code to tell you for certain.
[edit: Your later email seems to imply that you do not need all this information? Just ranges?]
Quoted 48 lines
Then we will face the problem that the potentially huge number of per-page data structures may not fit in the normal ram. Linux kernel developers came across the same problem, and their solution is to reserve an area of NVDIMM and put the page structures in the reserved area (https://lwn.net/Articles/672457/). I think we may take the similar solution:
(1) Dom0 Linux kernel reserves an area on each NVDIMM for Xen usage (besides the one used by Linux kernel itself) and reports the address and size to Xen hypervisor.Reasons to choose Linux kernel to make the reservation include:
(a) only Dom0 Linux kernel has the NVDIMM driver,
(b) make it flexible for Dom0 Linux kernel to handle all reservations (for itself and Xen).(2) Then Xen hypervisor builds the page structures for NVDIMM pages and stores them in above reserved areas.
(3) The reserved area is used as volatile, i.e. above two steps must be done for every host boot.
Quoted 5 lines
In effect Xen there are two guests (dom0 and domU) pointing in the P2M to the same GPFN. And that would mean:
Quoted 1 line
Quoted 1 line
Quoted 1 line
Quoted 1 line
(b) never map idx corresponding to GFNs occupied by vNVDIMM
Quoted 8 lines
Granted the
XENMAPSPACE_gmfnhappens _before_ the grant mapping is done so perhaps this is not an issue?The other situation I was envisioning - where the driver domain has the NVDIMM passed in, and as well SR-IOV network card and functions as an iSCSI target. That should work OK as we just need the IOMMU to have the NVDIMM GPFNs programmed in.
For this IOMMU usage example and above granted pages example, there remains one question: who is responsible to perform NVDIMM flush (clwb/clflushopt/pcommit)?
For the granted page example, if a NVDIMM page is granted to xen-netback, does the hypervisor need to tell xen-netback it's a NVDIMM page so that xen-netback can perform proper flush when it writes to that page? Or we may keep the NVDIMM transparent to xen-netback, and let Xen perform the flush when xen-netback gives up the granted NVDIMM page?
Quoted 5 lines
For the IOMMU example, my understanding is that there is a piece of software in the driver domain that handles SCSI commands received from network card and drives the network card to read/write certain areas of NVDIMM. Then that software should be aware of the existence of NVDIMM and perform the flush properly. Is that right?
I would imagine it is the same as any write on NVDIMM. The "owner" of the NVDIMM would perform the pcommit. ?
Quoted 2 lines
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 53 lines · Konrad Rzeszutek Wilk
Quoted 46 lines · Haozhong Zhang
Quoted 35 lines · Konrad Rzeszutek Wilk
Quoted 21 lines · Ian Jackson
Haozhong Zhang writes ("Re: [Xen-devel] [RFC Design Doc] Add vNVDIMM support for Xen"):
Quoted 11 lines · Konrad Rzeszutek Wilk
Quoted 9 lines
[someone:]
Quoted 3 lines
(2) For
XENMAPSPACE_gmfn,_gmfn_rangeand_gmfn_foreign,
(a) never map idx in them to GFNs occupied by vNVDIMM, and
(b) never map idx corresponding to GFNs occupied by vNVDIMMWould that mean that guest xen-blkback or xen-netback wouldn't be able to fetch data from the GFNs? As in, what if the HVM guest that has the NVDIMM also serves as a device domain - that is it has xen-blkback running to service other guests?
Quoted 8 lines
I'm not familiar with xen-blkback and xen-netback, so following statements maybe wrong.
In my understanding, xen-blkback/-netback in a device domain maps the pages from other domains into its own domain, and copies data between those pages and vNVDIMM. The access to vNVDIMM is performed by NVDIMM driver in device domain. In which steps of this procedure that xen-blkback/-netback needs to map into GFNs of vNVDIMM?
Quoted 6 lines
I think I agree with what you are saying. I don't understand exactly what you are proposing above in
XENMAPSPACE_gmfnbut I don't see how anything about this would interfere with blkback.blkback when talking to an nvdimm will just go through the block layer front door, and do a copy, I presume.
I believe you are right. The block layer, and then the fs would copy in.
Quoted 4 lines
I don't see how netback comes into it at all.
But maybe I am just confused or ignorant! Please do explain :-).
Quoted 9 lines
s/back/frontend/
My fear was refcounting.
Specifically where we do not do copying. For example, you could be sending data from the NVDIMM GFNs (scp?) to some other location (another host?). It would go over the xen-netback (in the dom0)
- which would then grant map it (dom0 would).Quoted 5 lines
Thanks for the explanation!
It means NVDIMM is very possibly mapped in page granularity, and hypervisor needs per-page data structures like
page_info(rather than the range set stylenvdimm_pages) to manage those mappings.
Quoted 6 lines
I do not know. I figured you need some accounting in the hypervisor as the pages can be grant mapped but I don't know the intricate details of the P2M code to tell you for certain.
[edit: Your later email seems to imply that you do not need all this information? Just ranges?]
Not quite sure which one do you mean. But at least in this example, NVDIMM can be granted in the unit of page, so I think Xen still needs per-page data structure to track this mapping information and range structure is not enough.
Quoted 48 lines
Quoted 48 lines
Then we will face the problem that the potentially huge number of per-page data structures may not fit in the normal ram. Linux kernel developers came across the same problem, and their solution is to reserve an area of NVDIMM and put the page structures in the reserved area (https://lwn.net/Articles/672457/). I think we may take the similar solution:
(1) Dom0 Linux kernel reserves an area on each NVDIMM for Xen usage (besides the one used by Linux kernel itself) and reports the address and size to Xen hypervisor.Reasons to choose Linux kernel to make the reservation include:
(a) only Dom0 Linux kernel has the NVDIMM driver,
(b) make it flexible for Dom0 Linux kernel to handle all reservations (for itself and Xen).(2) Then Xen hypervisor builds the page structures for NVDIMM pages and stores them in above reserved areas.
(3) The reserved area is used as volatile, i.e. above two steps must be done for every host boot.
Quoted 5 lines
In effect Xen there are two guests (dom0 and domU) pointing in the P2M to the same GPFN. And that would mean:
Quoted 1 line
Quoted 1 line
Quoted 1 line
Quoted 1 line
(b) never map idx corresponding to GFNs occupied by vNVDIMM
Quoted 8 lines
Granted the
XENMAPSPACE_gmfnhappens _before_ the grant mapping is done so perhaps this is not an issue?The other situation I was envisioning - where the driver domain has the NVDIMM passed in, and as well SR-IOV network card and functions as an iSCSI target. That should work OK as we just need the IOMMU to have the NVDIMM GPFNs programmed in.
For this IOMMU usage example and above granted pages example, there remains one question: who is responsible to perform NVDIMM flush (clwb/clflushopt/pcommit)?
For the granted page example, if a NVDIMM page is granted to xen-netback, does the hypervisor need to tell xen-netback it's a NVDIMM page so that xen-netback can perform proper flush when it writes to that page? Or we may keep the NVDIMM transparent to xen-netback, and let Xen perform the flush when xen-netback gives up the granted NVDIMM page?
Quoted 8 lines
Quoted 5 lines
For the IOMMU example, my understanding is that there is a piece of software in the driver domain that handles SCSI commands received from network card and drives the network card to read/write certain areas of NVDIMM. Then that software should be aware of the existence of NVDIMM and perform the flush properly. Is that right?
I would imagine it is the same as any write on NVDIMM. The "owner" of the NVDIMM would perform the pcommit. ?
Agree, software accessing NVDIMM is responsible to perform proper flush.
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 2 lines
Quoted 1 line
Quoted 1 line · On 01.02.16 at 06:44, <[email protected]> wrote:
This design treats host NVDIMM devices as ordinary MMIO devices:
Wrt the cachability note earlier on, I assume you're aware that with the XSA-154 changes we disallow any cachable mappings of MMIO by default.
Quoted 24 lines
(1) Dom0 Linux NVDIMM driver is responsible to detect (through NFIT) and drive host NVDIMM devices (implementing block device interface). Namespaces and file systems on host NVDIMM devices are handled by Dom0 Linux as well.
(2) QEMU mmap(2) the pmem NVDIMM devices (
/dev/pmem0) into its virtual address space (buf).(3) QEMU gets the host physical address of buf, i.e. the host system physical address that is occupied by
/dev/pmem0, and calls Xen hypercallXEN_DOMCTL_memory_mappingto map it to a DomU.(ACPI part is described in Section 3.3 later)
Above (1)(2) have already been done in current QEMU. Only (3) is needed to implement in QEMU. No change is needed in Xen for address mapping in this design.
Open: It seems no system call/ioctl is provided by Linux kernel to
get the physical address from a virtual address. /proc/<qemu_pid>/pagemap provides information of mapping from VA to PA. Is it an acceptable solution to let QEMU parse this file to get the physical address?
Quoted 6 lines
Open: For a large pmem, mmap(2) is very possible to not map all SPA
occupied by pmem at the beginning, i.e. QEMU may not be able to get all SPA of pmem from buf (in virtual address space) when callingXEN_DOMCTL_memory_mapping.
Can mmap flagMAP_LOCKEDor mlock(2) be used to enforce the entire pmem being mmaped?
A fundamental question I have here is: Why does qemu need to map this at all? It shouldn't itself need to access those ranges, since the guest is given direct access. It would seem quite a bit more natural if qemu simply inquired to underlying GFN range(s) and handed those to Xen for translation to MFNs and mapping into guest space.
Quoted 5 lines
I notice that current
XEN_DOMCTL_memory_mappingdoes not make santiy check for the physical address and size passed from caller (QEMU). Can QEMU be always trusted? If not, we would need to make Xen aware of the SPA range of pmem so that it can refuse map physical address in neither the normal ram nor pmem.
I'm not sure what missing sanity checks this is about: The handling involves two iomem_access_permitted() calls.
Quoted 26 lines
3.3 Guest ACPI Emulation
3.3.1 My Design
Guest ACPI emulation is composed of two parts: building guest NFIT and SSDT that defines ACPI namespace devices for NVDIMM, and emulating guest
_DSM.(1) Building Guest ACPI Tables
This design reuses and extends hvmloader's existing mechanism that loads passthrough ACPI tables from binary files to load NFIT and SSDT tables built by QEMU:
1) Because the current QEMU does not building any ACPI tables when it runs as the Xen device model, this design needs to patch QEMU to build NFIT and SSDT (so far only NFIT and SSDT) in this case.2) QEMU copies NFIT and SSDT to the end of guest memory below 4G. The guest address and size of those tables are written into xenstore (/local/domain/domid/hvmloader/dm-acpi/{address,length}).
3) hvmloader is patched to probe and load device model passthrough ACPI tables from above xenstore keys. The detected ACPI tables are then appended to the end of existing guest ACPI tables just like what current
construct_passthrough_tables()does.
Quoted 5 lines
Reasons for this design are listed below:
- NFIT and SSDT in question are quite self-contained, i.e. they do not refer to other ACPI tables and not conflict with existing guest ACPI tables in Xen. Therefore, it is safe to copy them from QEMU and append to existing guest ACPI tables.
How is this not conflicting being guaranteed? In particular I don't see how tables containing AML code and coming from different sources won't possibly cause ACPI name space collisions.
Quoted 19 lines
3.3.3 Alternative Design 2: keeping in Xen
Alternative to switching to QEMU, another design would be building NFIT and SSDT in hvmloader or toolstack.
The amount and parameters of sub-structures in guest NFIT vary according to different vNVDIMM configurations that can not be decided at compile-time. In contrast, current hvmloader and toolstack can only build static ACPI tables, i.e. their contents are decided statically at compile-time and independent from the guest configuration. In order to build guest NFIT at runtime, this design may take following steps:
(1) xl converts NVDIMM configurations in xl.cfg to corresponding QEMU options,(2) QEMU accepts above options, figures out the start SPA range address/size/NVDIMM device handles/..., and writes them in xenstore. No ACPI table is built by QEMU.
Quoted 6 lines
(3) Either xl or hvmloader reads above parameters from xenstore and builds the NFIT table.
For guest SSDT, it would take more work. The ACPI namespace devices are defined in SSDT by AML, so an AML builder would be needed to generate those definitions at runtime.
I'm not sure this last half sentence is true: We do some dynamic initialization of the pre-generated DSDT already, using the runtime populated block at ACPI_INFO_PHYSICAL_ADDRESS.
Jan
Quoted 7 lines · Jan Beulich
Quoted 2 lines
Quoted 1 line
Quoted 1 line · On 01.02.16 at 06:44, <[email protected]> wrote:
This design treats host NVDIMM devices as ordinary MMIO devices:
Wrt the cachability note earlier on, I assume you're aware that with the XSA-154 changes we disallow any cachable mappings of MMIO by default.
EPT entries that map the host NVDIMM SPAs to guest will be the only mapping used for NVDIMM. If the memory type in the last level entries is always set to the same type reported by NFIT and the ipat bit is always set as well, I think it would not suffer from the cache-type inconsistency problem in XSA-154?
Quoted 31 lines
Quoted 24 lines
(1) Dom0 Linux NVDIMM driver is responsible to detect (through NFIT) and drive host NVDIMM devices (implementing block device interface). Namespaces and file systems on host NVDIMM devices are handled by Dom0 Linux as well.
(2) QEMU mmap(2) the pmem NVDIMM devices (
/dev/pmem0) into its virtual address space (buf).(3) QEMU gets the host physical address of buf, i.e. the host system physical address that is occupied by
/dev/pmem0, and calls Xen hypercallXEN_DOMCTL_memory_mappingto map it to a DomU.(ACPI part is described in Section 3.3 later)
Above (1)(2) have already been done in current QEMU. Only (3) is needed to implement in QEMU. No change is needed in Xen for address mapping in this design.
Open: It seems no system call/ioctl is provided by Linux kernel to
get the physical address from a virtual address. /proc/<qemu_pid>/pagemap provides information of mapping from VA to PA. Is it an acceptable solution to let QEMU parse this file to get the physical address?Quoted 6 lines
Open: For a large pmem, mmap(2) is very possible to not map all SPA
occupied by pmem at the beginning, i.e. QEMU may not be able to get all SPA of pmem from buf (in virtual address space) when callingXEN_DOMCTL_memory_mapping.
Can mmap flagMAP_LOCKEDor mlock(2) be used to enforce the entire pmem being mmaped?
Quoted 7 lines
A fundamental question I have here is: Why does qemu need to map this at all? It shouldn't itself need to access those ranges, since the guest is given direct access. It would seem quite a bit more natural if qemu simply inquired to underlying GFN range(s) and handed those to Xen for translation to MFNs and mapping into guest space.
The above design is more like a hack on the existing QEMU implementation for KVM without modifying the Dom0 kernel.
Maybe it's better to let QEMU to get SPAs from Dom0 kernel (NVDIMM driver) and then pass them to Xen for the address mapping:
(1) QEMU passes fd of /dev/pmemN or file on /dev/pmemN to Dom0 kernel.
(2) Dom0 kernel finds and returns all SPAs occupied by /dev/pmemN or portions of /dev/pmemN where the file sits.
(3) QEMU passes above SPAs, and GMFN where they will be mapped to Xen which maps SPAs to GMFN.
Quoted 9 lines
Quoted 5 lines
I notice that current
XEN_DOMCTL_memory_mappingdoes not make santiy check for the physical address and size passed from caller (QEMU). Can QEMU be always trusted? If not, we would need to make Xen aware of the SPA range of pmem so that it can refuse map physical address in neither the normal ram nor pmem.I'm not sure what missing sanity checks this is about: The handling involves two
iomem_access_permitted()calls.
Oh, I missed iomem_access_permitted(). Seemingly it is what I need if the SPA ranges of host NVDIMMs are added to Dom0's iomem_cap initially.
Quoted 32 lines
Quoted 26 lines
3.3 Guest ACPI Emulation
3.3.1 My Design
Guest ACPI emulation is composed of two parts: building guest NFIT and SSDT that defines ACPI namespace devices for NVDIMM, and emulating guest
_DSM.(1) Building Guest ACPI Tables
This design reuses and extends hvmloader's existing mechanism that loads passthrough ACPI tables from binary files to load NFIT and SSDT tables built by QEMU:
1) Because the current QEMU does not building any ACPI tables when it runs as the Xen device model, this design needs to patch QEMU to build NFIT and SSDT (so far only NFIT and SSDT) in this case.2) QEMU copies NFIT and SSDT to the end of guest memory below 4G. The guest address and size of those tables are written into xenstore (/local/domain/domid/hvmloader/dm-acpi/{address,length}).
3) hvmloader is patched to probe and load device model passthrough ACPI tables from above xenstore keys. The detected ACPI tables are then appended to the end of existing guest ACPI tables just like what current
construct_passthrough_tables()does.Quoted 5 lines
Reasons for this design are listed below:
- NFIT and SSDT in question are quite self-contained, i.e. they do not refer to other ACPI tables and not conflict with existing guest ACPI tables in Xen. Therefore, it is safe to copy them from QEMU and append to existing guest ACPI tables.
Quoted 4 lines
How is this not conflicting being guaranteed? In particular I don't see how tables containing AML code and coming from different sources won't possibly cause ACPI name space collisions.
Really there is no effective mechanism to avoid ACPI name space collisions (and other kinds of conflicts) between ACPI tables loaded from QEMU and ACPI tables built by hvmloader. Because which ACPI tables are loaded is determined by developers, IMO it's developers' responsibility to avoid any collisions and conflicts with existing ACPI tables.
Quoted 22 lines
Quoted 22 lines
3.3.3 Alternative Design 2: keeping in Xen
Alternative to switching to QEMU, another design would be building NFIT and SSDT in hvmloader or toolstack.
The amount and parameters of sub-structures in guest NFIT vary according to different vNVDIMM configurations that can not be decided at compile-time. In contrast, current hvmloader and toolstack can only build static ACPI tables, i.e. their contents are decided statically at compile-time and independent from the guest configuration. In order to build guest NFIT at runtime, this design may take following steps:
(1) xl converts NVDIMM configurations in xl.cfg to corresponding QEMU options,(2) QEMU accepts above options, figures out the start SPA range address/size/NVDIMM device handles/..., and writes them in xenstore. No ACPI table is built by QEMU.
(3) Either xl or hvmloader reads above parameters from xenstore and builds the NFIT table.
Quoted 8 lines
Quoted 3 lines
For guest SSDT, it would take more work. The ACPI namespace devices are defined in SSDT by AML, so an AML builder would be needed to generate those definitions at runtime.
I'm not sure this last half sentence is true: We do some dynamic initialization of the pre-generated DSDT already, using the runtime populated block at
ACPI_INFO_PHYSICAL_ADDRESS.
IIUC, if an ACPI namespace device in guest DSDT needs to use an parameter that is not available at build time, it can refer to the corresponding field in the memory block at ACPI_INFO_PHYSICAL_ADDRESS that is filled at runtime.
But it does not work for vNVDIMM. An example of NVDIMM AML code looks like:
Scope (\_SB){
Device (NVDR) // Root device for all NVDIMM devices
{
Name (_HID, “ACPI0012”)
Method (_STA) {...}
Method (_FIT) {...}
Method (_DSM, ...) {
...
}
Device (NVD0) // 1st NVDIMM device
{
Name(_ADR, h) //where h is NFIT Device Handle for this NVDIMM
Method (_DSM, ...) {
...
}
}
Device (NVD1) // 2nd NVDIMM device
{
Name(_ADR, h) //where h is NFIT Device Handle for this NVDIMM
Method (_DSM, ...) {
...
}
}
... }
}
For each NVDIMM device defined in NFIT, there is a ACPI namespace device (e.g. NVD0, NVD1) under the root NVDIMM device (NVDR). Because the number of vNVDIMM devices are unknown at build time, we can not determine whether and how many NVDIMM ACPI namespace devices should be defined in the pre-generated SSDT.
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 188 lines · Haozhong Zhang
Quoted 7 lines · Jan Beulich
Quoted 2 lines
Quoted 1 line
Quoted 1 line · On 01.02.16 at 06:44, <[email protected]> wrote:
This design treats host NVDIMM devices as ordinary MMIO devices:
Wrt the cachability note earlier on, I assume you're aware that with the XSA-154 changes we disallow any cachable mappings of MMIO by default.
EPT entries that map the host NVDIMM SPAs to guest will be the only mapping used for NVDIMM. If the memory type in the last level entries is always set to the same type reported by NFIT and the ipat bit is always set as well, I think it would not suffer from the cache-type inconsistency problem in XSA-154?
Quoted 31 lines
Quoted 24 lines
(1) Dom0 Linux NVDIMM driver is responsible to detect (through NFIT) and drive host NVDIMM devices (implementing block device interface). Namespaces and file systems on host NVDIMM devices are handled by Dom0 Linux as well.
(2) QEMU mmap(2) the pmem NVDIMM devices (
/dev/pmem0) into its virtual address space (buf).(3) QEMU gets the host physical address of buf, i.e. the host system physical address that is occupied by
/dev/pmem0, and calls Xen hypercallXEN_DOMCTL_memory_mappingto map it to a DomU.(ACPI part is described in Section 3.3 later)
Above (1)(2) have already been done in current QEMU. Only (3) is needed to implement in QEMU. No change is needed in Xen for address mapping in this design.
Open: It seems no system call/ioctl is provided by Linux kernel to
get the physical address from a virtual address. /proc/<qemu_pid>/pagemap provides information of mapping from VA to PA. Is it an acceptable solution to let QEMU parse this file to get the physical address?Quoted 6 lines
Open: For a large pmem, mmap(2) is very possible to not map all SPA
occupied by pmem at the beginning, i.e. QEMU may not be able to get all SPA of pmem from buf (in virtual address space) when callingXEN_DOMCTL_memory_mapping.
Can mmap flagMAP_LOCKEDor mlock(2) be used to enforce the entire pmem being mmaped?Quoted 7 lines
A fundamental question I have here is: Why does qemu need to map this at all? It shouldn't itself need to access those ranges, since the guest is given direct access. It would seem quite a bit more natural if qemu simply inquired to underlying GFN range(s) and handed those to Xen for translation to MFNs and mapping into guest space.
The above design is more like a hack on the existing QEMU implementation for KVM without modifying the Dom0 kernel.
Maybe it's better to let QEMU to get SPAs from Dom0 kernel (NVDIMM driver) and then pass them to Xen for the address mapping:
(1) QEMU passes fd of/dev/pmemNor file on/dev/pmemNto Dom0 kernel.
(2) Dom0 kernel finds and returns all SPAs occupied by/dev/pmemNor portions of/dev/pmemNwhere the file sits.
(3) QEMU passes above SPAs, and GMFN where they will be mapped to Xen which maps SPAs to GMFN.Quoted 9 lines
Quoted 5 lines
I notice that current
XEN_DOMCTL_memory_mappingdoes not make santiy check for the physical address and size passed from caller (QEMU). Can QEMU be always trusted? If not, we would need to make Xen aware of the SPA range of pmem so that it can refuse map physical address in neither the normal ram nor pmem.I'm not sure what missing sanity checks this is about: The handling involves two
iomem_access_permitted()calls.Oh, I missed
iomem_access_permitted(). Seemingly it is what I need if the SPA ranges of host NVDIMMs are added to Dom0'siomem_capinitially.Quoted 32 lines
Quoted 26 lines
3.3 Guest ACPI Emulation
3.3.1 My Design
Guest ACPI emulation is composed of two parts: building guest NFIT and SSDT that defines ACPI namespace devices for NVDIMM, and emulating guest
_DSM.(1) Building Guest ACPI Tables
This design reuses and extends hvmloader's existing mechanism that loads passthrough ACPI tables from binary files to load NFIT and SSDT tables built by QEMU:
1) Because the current QEMU does not building any ACPI tables when it runs as the Xen device model, this design needs to patch QEMU to build NFIT and SSDT (so far only NFIT and SSDT) in this case.2) QEMU copies NFIT and SSDT to the end of guest memory below 4G. The guest address and size of those tables are written into xenstore (/local/domain/domid/hvmloader/dm-acpi/{address,length}).
3) hvmloader is patched to probe and load device model passthrough ACPI tables from above xenstore keys. The detected ACPI tables are then appended to the end of existing guest ACPI tables just like what current
construct_passthrough_tables()does.Quoted 5 lines
Reasons for this design are listed below:
- NFIT and SSDT in question are quite self-contained, i.e. they do not refer to other ACPI tables and not conflict with existing guest ACPI tables in Xen. Therefore, it is safe to copy them from QEMU and append to existing guest ACPI tables.Quoted 4 lines
How is this not conflicting being guaranteed? In particular I don't see how tables containing AML code and coming from different sources won't possibly cause ACPI name space collisions.
Really there is no effective mechanism to avoid ACPI name space collisions (and other kinds of conflicts) between ACPI tables loaded from QEMU and ACPI tables built by hvmloader. Because which ACPI tables are loaded is determined by developers, IMO it's developers' responsibility to avoid any collisions and conflicts with existing ACPI tables.
Quoted 22 lines
Quoted 22 lines
3.3.3 Alternative Design 2: keeping in Xen
Alternative to switching to QEMU, another design would be building NFIT and SSDT in hvmloader or toolstack.
The amount and parameters of sub-structures in guest NFIT vary according to different vNVDIMM configurations that can not be decided at compile-time. In contrast, current hvmloader and toolstack can only build static ACPI tables, i.e. their contents are decided statically at compile-time and independent from the guest configuration. In order to build guest NFIT at runtime, this design may take following steps:
(1) xl converts NVDIMM configurations in xl.cfg to corresponding QEMU options,(2) QEMU accepts above options, figures out the start SPA range address/size/NVDIMM device handles/..., and writes them in xenstore. No ACPI table is built by QEMU.
(3) Either xl or hvmloader reads above parameters from xenstore and builds the NFIT table.
Quoted 8 lines
Quoted 3 lines
For guest SSDT, it would take more work. The ACPI namespace devices are defined in SSDT by AML, so an AML builder would be needed to generate those definitions at runtime.
I'm not sure this last half sentence is true: We do some dynamic initialization of the pre-generated DSDT already, using the runtime populated block at
ACPI_INFO_PHYSICAL_ADDRESS.IIUC, if an ACPI namespace device in guest DSDT needs to use an parameter that is not available at build time, it can refer to the corresponding field in the memory block at
ACPI_INFO_PHYSICAL_ADDRESSthat is filled at runtime.But it does not work for vNVDIMM. An example of NVDIMM AML code looks like:
Scope (\_SB){ Device (NVDR) // Root device for all NVDIMM devices { Name (_HID, “ACPI0012”) Method (_STA) {...} Method (_FIT) {...} Method (_DSM, ...) { ... } Device (NVD0) // 1st NVDIMM device { Name(_ADR, h) //where h is NFIT Device Handle for this NVDIMM Method (_DSM, ...) { ... } } Device (NVD1) // 2nd NVDIMM device { Name(_ADR, h) //where h is NFIT Device Handle for this NVDIMM Method (_DSM, ...) { ... } } ...
Quoted 8 lines
}
}For each NVDIMM device defined in NFIT, there is a ACPI namespace device (e.g. NVD0, NVD1) under the root NVDIMM device (NVDR). Because the number of vNVDIMM devices are unknown at build time, we can not determine whether and how many NVDIMM ACPI namespace devices should be defined in the pre-generated SSDT.
We have dealt with the exact same issue in the past (though it concerned WMI ACPI devices). The layout and number of these devices and their methods was very platform dependent as this seems to be. Thus we generated an SSDT at runtime to reflect the underlying platform. At that time we had to write an AML generator but as noted earlier, SeaBIOS now seems to have a fairly complete one. This would allow you to do create the proper number of NVDx devices and set the desired addresses at runtime.
If you have to do it statically at build time you will have to pick a max number of possible NVDx devices and make some of them report they are not there (e.g. w/ the _STA methods possibly). In this case you could extend ACPI_INFO_PHYSICAL_ADDRESS or create your own IO/Memory OpRegion that you handle at runtime. I would personally go for the first option.
Quoted 8 lines
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Signature · 1 line
Ross Philipson
On 02/24/16 09:00, Ross Philipson wrote:
[...]
Quoted 6 lines
Quoted 5 lines
For each NVDIMM device defined in NFIT, there is a ACPI namespace device (e.g. NVD0, NVD1) under the root NVDIMM device (NVDR). Because the number of vNVDIMM devices are unknown at build time, we can not determine whether and how many NVDIMM ACPI namespace devices should be defined in the pre-generated SSDT.
Quoted 8 lines
We have dealt with the exact same issue in the past (though it concerned WMI ACPI devices). The layout and number of these devices and their methods was very platform dependent as this seems to be. Thus we generated an SSDT at runtime to reflect the underlying platform. At that time we had to write an AML generator but as noted earlier, SeaBIOS now seems to have a fairly complete one. This would allow you to do create the proper number of NVDx devices and set the desired addresses at runtime.
Thanks for the information. I just did a quick grep on SeaBIOS code and found some AML related code in scripts/acpi_extract.py. Is this the AML generator you mean?
Quoted 7 lines
If you have to do it statically at build time you will have to pick a max number of possible NVDx devices and make some of them report they are not there (e.g. w/ the
_STAmethods possibly). In this case you could extendACPI_INFO_PHYSICAL_ADDRESSor create your own IO/Memory OpRegion that you handle at runtime. I would personally go for the first option.
_STA does not work, because the individual NVDIMM ACPI namespace device (NVDx) does no provide _STA method. In addition, ACPI spec does not define any mechanism to check the presence of an individual NVDx.
Haozhong
Quoted 17 lines · Haozhong Zhang
On 02/24/16 09:00, Ross Philipson wrote:
[...]Quoted 6 lines
Quoted 5 lines
For each NVDIMM device defined in NFIT, there is a ACPI namespace device (e.g. NVD0, NVD1) under the root NVDIMM device (NVDR). Because the number of vNVDIMM devices are unknown at build time, we can not determine whether and how many NVDIMM ACPI namespace devices should be defined in the pre-generated SSDT.
Quoted 8 lines
We have dealt with the exact same issue in the past (though it concerned WMI ACPI devices). The layout and number of these devices and their methods was very platform dependent as this seems to be. Thus we generated an SSDT at runtime to reflect the underlying platform. At that time we had to write an AML generator but as noted earlier, SeaBIOS now seems to have a fairly complete one. This would allow you to do create the proper number of NVDx devices and set the desired addresses at runtime.
Quoted 3 lines
Thanks for the information. I just did a quick grep on SeaBIOS code and found some AML related code in
scripts/acpi_extract.py. Is this the AML generator you mean?
Oh terribly sorry - I am talking about QEMU. The code in hw/acpi/aml-build.c looks like it does a lot of what my library does. I don't know how complete it is. For example I had to do a lot of work to build resource packages and I have not found that yet. But it is a good starting place.
Quoted 15 lines
Quoted 8 lines
If you have to do it statically at build time you will have to pick a max number of possible NVDx devices and make some of them report they are not there (e.g. w/ the
_STAmethods possibly). In this case you could extendACPI_INFO_PHYSICAL_ADDRESSor create your own IO/Memory OpRegion that you handle at runtime. I would personally go for the first option.
_STAdoes not work, because the individual NVDIMM ACPI namespace device (NVDx) does no provide_STAmethod. In addition, ACPI spec does not define any mechanism to check the presence of an individual NVDx.Haozhong
Signature · 1 line
Ross Philipson
Quoted 10 lines
Quoted 1 line
Quoted 1 line · On 24.02.16 at 14:28, <[email protected]> wrote:
Quoted 7 lines · Jan Beulich
Quoted 2 lines
Quoted 1 line
Quoted 1 line · On 01.02.16 at 06:44, <[email protected]> wrote:
This design treats host NVDIMM devices as ordinary MMIO devices:
Wrt the cachability note earlier on, I assume you're aware that with the XSA-154 changes we disallow any cachable mappings of MMIO by default.
Quoted 5 lines
EPT entries that map the host NVDIMM SPAs to guest will be the only mapping used for NVDIMM. If the memory type in the last level entries is always set to the same type reported by NFIT and the ipat bit is always set as well, I think it would not suffer from the cache-type inconsistency problem in XSA-154?
This assumes Xen knows the NVDIMM address ranges, which so far you meant to keep out of Xen iirc. But yes, things surely can be made work, I simply wanted to point out that there are some caveats.
Quoted 42 lines
Quoted 31 lines
Quoted 24 lines
(1) Dom0 Linux NVDIMM driver is responsible to detect (through NFIT) and drive host NVDIMM devices (implementing block device interface). Namespaces and file systems on host NVDIMM devices are handled by Dom0 Linux as well.
(2) QEMU mmap(2) the pmem NVDIMM devices (
/dev/pmem0) into its virtual address space (buf).(3) QEMU gets the host physical address of buf, i.e. the host system physical address that is occupied by
/dev/pmem0, and calls Xen hypercallXEN_DOMCTL_memory_mappingto map it to a DomU.(ACPI part is described in Section 3.3 later)
Above (1)(2) have already been done in current QEMU. Only (3) is needed to implement in QEMU. No change is needed in Xen for address mapping in this design.
Open: It seems no system call/ioctl is provided by Linux kernel to
get the physical address from a virtual address. /proc/<qemu_pid>/pagemap provides information of mapping from VA to PA. Is it an acceptable solution to let QEMU parse this file to get the physical address?Quoted 6 lines
Open: For a large pmem, mmap(2) is very possible to not map all SPA
occupied by pmem at the beginning, i.e. QEMU may not be able to get all SPA of pmem from buf (in virtual address space) when callingXEN_DOMCTL_memory_mapping.
Can mmap flagMAP_LOCKEDor mlock(2) be used to enforce the entire pmem being mmaped?Quoted 7 lines
A fundamental question I have here is: Why does qemu need to map this at all? It shouldn't itself need to access those ranges, since the guest is given direct access. It would seem quite a bit more natural if qemu simply inquired to underlying GFN range(s) and handed those to Xen for translation to MFNs and mapping into guest space.
The above design is more like a hack on the existing QEMU implementation for KVM without modifying the Dom0 kernel.
Quoted 7 lines
Maybe it's better to let QEMU to get SPAs from Dom0 kernel (NVDIMM driver) and then pass them to Xen for the address mapping:
(1) QEMU passes fd of/dev/pmemNor file on/dev/pmemNto Dom0 kernel.
(2) Dom0 kernel finds and returns all SPAs occupied by/dev/pmemNor portions of/dev/pmemNwhere the file sits.
(3) QEMU passes above SPAs, and GMFN where they will be mapped to Xen which maps SPAs to GMFN.
Indeed, and that would also eliminate the second of your Opens above.
Quoted 37 lines
Quoted 32 lines
Quoted 26 lines
3.3 Guest ACPI Emulation
3.3.1 My Design
Guest ACPI emulation is composed of two parts: building guest NFIT and SSDT that defines ACPI namespace devices for NVDIMM, and emulating guest
_DSM.(1) Building Guest ACPI Tables
This design reuses and extends hvmloader's existing mechanism that loads passthrough ACPI tables from binary files to load NFIT and SSDT tables built by QEMU:
1) Because the current QEMU does not building any ACPI tables when it runs as the Xen device model, this design needs to patch QEMU to build NFIT and SSDT (so far only NFIT and SSDT) in this case.2) QEMU copies NFIT and SSDT to the end of guest memory below 4G. The guest address and size of those tables are written into xenstore (/local/domain/domid/hvmloader/dm-acpi/{address,length}).
3) hvmloader is patched to probe and load device model passthrough ACPI tables from above xenstore keys. The detected ACPI tables are then appended to the end of existing guest ACPI tables just like what current
construct_passthrough_tables()does.Quoted 5 lines
Reasons for this design are listed below:
- NFIT and SSDT in question are quite self-contained, i.e. they do not refer to other ACPI tables and not conflict with existing guest ACPI tables in Xen. Therefore, it is safe to copy them from QEMU and append to existing guest ACPI tables.Quoted 4 lines
How is this not conflicting being guaranteed? In particular I don't see how tables containing AML code and coming from different sources won't possibly cause ACPI name space collisions.
Quoted 6 lines
Really there is no effective mechanism to avoid ACPI name space collisions (and other kinds of conflicts) between ACPI tables loaded from QEMU and ACPI tables built by hvmloader. Because which ACPI tables are loaded is determined by developers, IMO it's developers' responsibility to avoid any collisions and conflicts with existing ACPI tables.
Right, but this needs to be spelled out and settled on at design time (i.e. now), rather leaving things unspecified, awaiting the first clash.
Jan
Quoted 10 lines · Jan Beulich
Quoted 10 lines
Quoted 1 line
Quoted 1 line · On 24.02.16 at 14:28, <[email protected]> wrote:
Quoted 7 lines · Jan Beulich
Quoted 2 lines
Quoted 1 line
Quoted 1 line · On 01.02.16 at 06:44, <[email protected]> wrote:
This design treats host NVDIMM devices as ordinary MMIO devices:
Wrt the cachability note earlier on, I assume you're aware that with the XSA-154 changes we disallow any cachable mappings of MMIO by default.
Quoted 8 lines
Quoted 5 lines
EPT entries that map the host NVDIMM SPAs to guest will be the only mapping used for NVDIMM. If the memory type in the last level entries is always set to the same type reported by NFIT and the ipat bit is always set as well, I think it would not suffer from the cache-type inconsistency problem in XSA-154?
This assumes Xen knows the NVDIMM address ranges, which so far you meant to keep out of Xen iirc.
The original design did not consider and failed for some cases, such as XSA-154 and MCE handling. For those two cases, Xen really should track mapping for NVDIMM. (Yes, I changed my mind)
Quoted 54 lines
But yes, things surely can
be made work, I simply wanted to point out that there are some caveats.Quoted 42 lines
Quoted 31 lines
Quoted 24 lines
(1) Dom0 Linux NVDIMM driver is responsible to detect (through NFIT) and drive host NVDIMM devices (implementing block device interface). Namespaces and file systems on host NVDIMM devices are handled by Dom0 Linux as well.
(2) QEMU mmap(2) the pmem NVDIMM devices (
/dev/pmem0) into its virtual address space (buf).(3) QEMU gets the host physical address of buf, i.e. the host system physical address that is occupied by
/dev/pmem0, and calls Xen hypercallXEN_DOMCTL_memory_mappingto map it to a DomU.(ACPI part is described in Section 3.3 later)
Above (1)(2) have already been done in current QEMU. Only (3) is needed to implement in QEMU. No change is needed in Xen for address mapping in this design.
Open: It seems no system call/ioctl is provided by Linux kernel to
get the physical address from a virtual address. /proc/<qemu_pid>/pagemap provides information of mapping from VA to PA. Is it an acceptable solution to let QEMU parse this file to get the physical address?Quoted 6 lines
Open: For a large pmem, mmap(2) is very possible to not map all SPA
occupied by pmem at the beginning, i.e. QEMU may not be able to get all SPA of pmem from buf (in virtual address space) when callingXEN_DOMCTL_memory_mapping.
Can mmap flagMAP_LOCKEDor mlock(2) be used to enforce the entire pmem being mmaped?Quoted 7 lines
A fundamental question I have here is: Why does qemu need to map this at all? It shouldn't itself need to access those ranges, since the guest is given direct access. It would seem quite a bit more natural if qemu simply inquired to underlying GFN range(s) and handed those to Xen for translation to MFNs and mapping into guest space.
The above design is more like a hack on the existing QEMU implementation for KVM without modifying the Dom0 kernel.
Quoted 7 lines
Maybe it's better to let QEMU to get SPAs from Dom0 kernel (NVDIMM driver) and then pass them to Xen for the address mapping:
(1) QEMU passes fd of/dev/pmemNor file on/dev/pmemNto Dom0 kernel.
(2) Dom0 kernel finds and returns all SPAs occupied by/dev/pmemNor portions of/dev/pmemNwhere the file sits.
(3) QEMU passes above SPAs, and GMFN where they will be mapped to Xen which maps SPAs to GMFN.
Quoted 3 lines
Indeed, and that would also eliminate the second of your Opens above.
Yes.
Quoted 44 lines
Quoted 37 lines
Quoted 32 lines
Quoted 26 lines
3.3 Guest ACPI Emulation
3.3.1 My Design
Guest ACPI emulation is composed of two parts: building guest NFIT and SSDT that defines ACPI namespace devices for NVDIMM, and emulating guest
_DSM.(1) Building Guest ACPI Tables
This design reuses and extends hvmloader's existing mechanism that loads passthrough ACPI tables from binary files to load NFIT and SSDT tables built by QEMU:
1) Because the current QEMU does not building any ACPI tables when it runs as the Xen device model, this design needs to patch QEMU to build NFIT and SSDT (so far only NFIT and SSDT) in this case.2) QEMU copies NFIT and SSDT to the end of guest memory below 4G. The guest address and size of those tables are written into xenstore (/local/domain/domid/hvmloader/dm-acpi/{address,length}).
3) hvmloader is patched to probe and load device model passthrough ACPI tables from above xenstore keys. The detected ACPI tables are then appended to the end of existing guest ACPI tables just like what current
construct_passthrough_tables()does.Quoted 5 lines
Reasons for this design are listed below:
- NFIT and SSDT in question are quite self-contained, i.e. they do not refer to other ACPI tables and not conflict with existing guest ACPI tables in Xen. Therefore, it is safe to copy them from QEMU and append to existing guest ACPI tables.Quoted 4 lines
How is this not conflicting being guaranteed? In particular I don't see how tables containing AML code and coming from different sources won't possibly cause ACPI name space collisions.
Quoted 6 lines
Really there is no effective mechanism to avoid ACPI name space collisions (and other kinds of conflicts) between ACPI tables loaded from QEMU and ACPI tables built by hvmloader. Because which ACPI tables are loaded is determined by developers, IMO it's developers' responsibility to avoid any collisions and conflicts with existing ACPI tables.
Quoted 4 lines
Right, but this needs to be spelled out and settled on at design time (i.e. now), rather leaving things unspecified, awaiting the first clash.
So that means if no collision-proof mechanism is introduced, Xen should not trust any passed-in ACPI tables and should build them by itself?
Haozhong
Quoted 49 lines
Quoted 1 line
Quoted 1 line · On 24.02.16 at 16:48, <[email protected]> wrote:
Quoted 47 lines · Jan Beulich
Quoted 46 lines
Quoted 1 line
Quoted 1 line · On 24.02.16 at 14:28, <[email protected]> wrote:
Quoted 33 lines · Jan Beulich
Quoted 27 lines
Quoted 1 line
Quoted 1 line · On 01.02.16 at 06:44, <[email protected]> wrote:
3.3 Guest ACPI Emulation
3.3.1 My Design
Guest ACPI emulation is composed of two parts: building guest NFIT and SSDT that defines ACPI namespace devices for NVDIMM, and emulating guest
_DSM.(1) Building Guest ACPI Tables
This design reuses and extends hvmloader's existing mechanism that loads passthrough ACPI tables from binary files to load NFIT and SSDT tables built by QEMU:
1) Because the current QEMU does not building any ACPI tables when it runs as the Xen device model, this design needs to patch QEMU to build NFIT and SSDT (so far only NFIT and SSDT) in this case.2) QEMU copies NFIT and SSDT to the end of guest memory below 4G. The guest address and size of those tables are written into xenstore (/local/domain/domid/hvmloader/dm-acpi/{address,length}).
3) hvmloader is patched to probe and load device model passthrough ACPI tables from above xenstore keys. The detected ACPI tables are then appended to the end of existing guest ACPI tables just like what current
construct_passthrough_tables()does.Quoted 5 lines
Reasons for this design are listed below:
- NFIT and SSDT in question are quite self-contained, i.e. they do not refer to other ACPI tables and not conflict with existing guest ACPI tables in Xen. Therefore, it is safe to copy them from QEMU and append to existing guest ACPI tables.Quoted 4 lines
How is this not conflicting being guaranteed? In particular I don't see how tables containing AML code and coming from different sources won't possibly cause ACPI name space collisions.
Really there is no effective mechanism to avoid ACPI name space collisions (and other kinds of conflicts) between ACPI tables loaded from QEMU and ACPI tables built by hvmloader. Because which ACPI tables are loaded is determined by developers, IMO it's developers' responsibility to avoid any collisions and conflicts with existing ACPI tables.
Quoted 6 lines
Quoted 3 lines
Right, but this needs to be spelled out and settled on at design time (i.e. now), rather leaving things unspecified, awaiting the first clash.
So that means if no collision-proof mechanism is introduced, Xen should not trust any passed-in ACPI tables and should build them by itself?
Basically yes, albeit collision-proof may be too much to demand. Simply separating name spaces (for hvmloader and qemu to have their own sub-spaces) would be sufficient imo. We should trust ourselves to play by such a specification.
Jan
Quoted 53 lines · Jan Beulich
Quoted 53 lines
Quoted 1 line
Quoted 1 line · On 24.02.16 at 16:48, <[email protected]> wrote:
Quoted 50 lines · Jan Beulich
Quoted 40 lines
Quoted 1 line
Quoted 1 line · On 24.02.16 at 14:28, <[email protected]> wrote:
Quoted 33 lines · Jan Beulich
Quoted 27 lines
Quoted 1 line
Quoted 1 line · On 01.02.16 at 06:44, <[email protected]> wrote:
3.3 Guest ACPI Emulation
3.3.1 My Design
Guest ACPI emulation is composed of two parts: building guest NFIT and SSDT that defines ACPI namespace devices for NVDIMM, and emulating guest
_DSM.(1) Building Guest ACPI Tables
This design reuses and extends hvmloader's existing mechanism that loads passthrough ACPI tables from binary files to load NFIT and SSDT tables built by QEMU:
1) Because the current QEMU does not building any ACPI tables when it runs as the Xen device model, this design needs to patch QEMU to build NFIT and SSDT (so far only NFIT and SSDT) in this case.2) QEMU copies NFIT and SSDT to the end of guest memory below 4G. The guest address and size of those tables are written into xenstore (/local/domain/domid/hvmloader/dm-acpi/{address,length}).
3) hvmloader is patched to probe and load device model passthrough ACPI tables from above xenstore keys. The detected ACPI tables are then appended to the end of existing guest ACPI tables just like what current
construct_passthrough_tables()does.Quoted 5 lines
Reasons for this design are listed below:
- NFIT and SSDT in question are quite self-contained, i.e. they do not refer to other ACPI tables and not conflict with existing guest ACPI tables in Xen. Therefore, it is safe to copy them from QEMU and append to existing guest ACPI tables.Quoted 4 lines
How is this not conflicting being guaranteed? In particular I don't see how tables containing AML code and coming from different sources won't possibly cause ACPI name space collisions.
Quoted 6 lines
Really there is no effective mechanism to avoid ACPI name space collisions (and other kinds of conflicts) between ACPI tables loaded from QEMU and ACPI tables built by hvmloader. Because which ACPI tables are loaded is determined by developers, IMO it's developers' responsibility to avoid any collisions and conflicts with existing ACPI tables.
Right, but this needs to be spelled out and settled on at design time (i.e. now), rather leaving things unspecified, awaiting the first clash.
Quoted 8 lines
Quoted 2 lines
So that means if no collision-proof mechanism is introduced, Xen should not trust any passed-in ACPI tables and should build them by itself?
Basically yes, albeit collision-proof may be too much to demand. Simply separating name spaces (for hvmloader and qemu to have their own sub-spaces) would be sufficient imo. We should trust ourselves to play by such a specification.
I don't quite understand 'separating name spaces'. Do you mean, for example, if both hvmloader and qemu want to put a namespace device under \_SB, they could be put in different sub-scopes under \_SB? But it does not work for Linux at least.
Anyway, we may avoid some conflicts between ACPI tables/objects by restricting which tables and objects can be passed from QEMU to Xen:
(1) For ACPI tables, xen does not accept those built by itself, e.g. DSDT and SSDT.
(2) xen does not accept ACPI tables for devices that are not attached to a domain, e.g. if NFIT cannot be passed if a domain does not have vNVDIMM.
(3) For ACPI objects, xen only accepts namespace devices and requires their names does not conflict with existing ones provided by Xen.
In implementation, QEMU could put the passed-in ACPI tables and objects in a series of blobs in following format:
+------+------+--....--+ | type | size | data | +------+------+--....--+
where
(1) 'type' indicates which data are stored in this blob:
0 for ACPI table,
1 for ACPI namespace device,
(2) 'size' indicates this blob's size in bytes. The next blob (if exist) can be found by add 'size' to the base address of the current blob.
(3) 'data' is of variant-length and stores the actual passed content:
(a) for type 0 blob (ACPI table), a complete ACPI table including the table header is stored in 'data'
(b) for type 1 blob (ACPI namespace device), at the beginning of 'data' is a 4 bytes device name, and followed is AML code within that device, e.g. for a device
Device (DEV0) {
Name (_HID, "ACPI1234")
Method (_DSM) { ... }
}
"DEV0" is stored at the beginning of 'data', and then is AML code of
Name (_HID, "ACPI1234")
Method (_DSM) { ... }
The number and the starting guest address of all blobs are passed to Xen via xenstore. Xen toolstack/hvmloader can enumerate those blobs and check signatures or name in 'data' according to their types.
The acceptable ACPI tables will be appended to existing tables built by Xen. For acceptable ACPI namespace devices, hvmloader will recreate AML devices for them, and put those AML devices in a new SSDT. Only a small piece of code to build just AML device entry rather than a comprehensive AML builder is needed then.
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 64 lines
Quoted 1 line
Quoted 1 line · On 28.02.16 at 15:48, <[email protected]> wrote:
Quoted 53 lines · Jan Beulich
Quoted 53 lines
Quoted 1 line
Quoted 1 line · On 24.02.16 at 16:48, <[email protected]> wrote:
Quoted 50 lines · Jan Beulich
Quoted 40 lines
Quoted 1 line
Quoted 1 line · On 24.02.16 at 14:28, <[email protected]> wrote:
Quoted 33 lines · Jan Beulich
Quoted 27 lines
Quoted 1 line
Quoted 1 line · On 01.02.16 at 06:44, <[email protected]> wrote:
3.3 Guest ACPI Emulation
3.3.1 My Design
Guest ACPI emulation is composed of two parts: building guest NFIT and SSDT that defines ACPI namespace devices for NVDIMM, and emulating guest
_DSM.(1) Building Guest ACPI Tables
This design reuses and extends hvmloader's existing mechanism that loads passthrough ACPI tables from binary files to load NFIT and SSDT tables built by QEMU:
1) Because the current QEMU does not building any ACPI tables when it runs as the Xen device model, this design needs to patch QEMU to build NFIT and SSDT (so far only NFIT and SSDT) in this case.2) QEMU copies NFIT and SSDT to the end of guest memory below 4G. The guest address and size of those tables are written into xenstore (/local/domain/domid/hvmloader/dm-acpi/{address,length}).
3) hvmloader is patched to probe and load device model passthrough ACPI tables from above xenstore keys. The detected ACPI tables are then appended to the end of existing guest ACPI tables just like what current
construct_passthrough_tables()does.Quoted 5 lines
Reasons for this design are listed below:
- NFIT and SSDT in question are quite self-contained, i.e. they do not refer to other ACPI tables and not conflict with existing guest ACPI tables in Xen. Therefore, it is safe to copy them from QEMU and append to existing guest ACPI tables.Quoted 4 lines
How is this not conflicting being guaranteed? In particular I don't see how tables containing AML code and coming from different sources won't possibly cause ACPI name space collisions.
Quoted 6 lines
Really there is no effective mechanism to avoid ACPI name space collisions (and other kinds of conflicts) between ACPI tables loaded from QEMU and ACPI tables built by hvmloader. Because which ACPI tables are loaded is determined by developers, IMO it's developers' responsibility to avoid any collisions and conflicts with existing ACPI tables.
Right, but this needs to be spelled out and settled on at design time (i.e. now), rather leaving things unspecified, awaiting the first clash.
Quoted 8 lines
Quoted 2 lines
So that means if no collision-proof mechanism is introduced, Xen should not trust any passed-in ACPI tables and should build them by itself?
Basically yes, albeit collision-proof may be too much to demand. Simply separating name spaces (for hvmloader and qemu to have their own sub-spaces) would be sufficient imo. We should trust ourselves to play by such a specification.
Quoted 4 lines
I don't quite understand 'separating name spaces'. Do you mean, for example, if both hvmloader and qemu want to put a namespace device under \_SB, they could be put in different sub-scopes under \_SB? But it does not work for Linux at least.
Aiui just the leaf names matter for sufficient separation, i.e. recurring sub-scopes should not be a problem.
Quoted 9 lines
Anyway, we may avoid some conflicts between ACPI tables/objects by restricting which tables and objects can be passed from QEMU to Xen:
(1) For ACPI tables, xen does not accept those built by itself, e.g. DSDT and SSDT.
(2) xen does not accept ACPI tables for devices that are not attached to a domain, e.g. if NFIT cannot be passed if a domain does not have vNVDIMM.
(3) For ACPI objects, xen only accepts namespace devices and requires their names does not conflict with existing ones provided by Xen.
And how do you imagine to enforce this without parsing the handed AML? (Remember there's no AML parser in hvmloader.)
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 82 lines · Jan Beulich
Quoted 64 lines
Quoted 1 line
Quoted 1 line · On 28.02.16 at 15:48, <[email protected]> wrote:
Quoted 53 lines · Jan Beulich
Quoted 53 lines
Quoted 1 line
Quoted 1 line · On 24.02.16 at 16:48, <[email protected]> wrote:
Quoted 50 lines · Jan Beulich
Quoted 40 lines
Quoted 1 line
Quoted 1 line · On 24.02.16 at 14:28, <[email protected]> wrote:
Quoted 33 lines · Jan Beulich
Quoted 27 lines
Quoted 1 line
Quoted 1 line · On 01.02.16 at 06:44, <[email protected]> wrote:
3.3 Guest ACPI Emulation
3.3.1 My Design
Guest ACPI emulation is composed of two parts: building guest NFIT and SSDT that defines ACPI namespace devices for NVDIMM, and emulating guest
_DSM.(1) Building Guest ACPI Tables
This design reuses and extends hvmloader's existing mechanism that loads passthrough ACPI tables from binary files to load NFIT and SSDT tables built by QEMU:
1) Because the current QEMU does not building any ACPI tables when it runs as the Xen device model, this design needs to patch QEMU to build NFIT and SSDT (so far only NFIT and SSDT) in this case.2) QEMU copies NFIT and SSDT to the end of guest memory below 4G. The guest address and size of those tables are written into xenstore (/local/domain/domid/hvmloader/dm-acpi/{address,length}).
3) hvmloader is patched to probe and load device model passthrough ACPI tables from above xenstore keys. The detected ACPI tables are then appended to the end of existing guest ACPI tables just like what current
construct_passthrough_tables()does.Quoted 5 lines
Reasons for this design are listed below:
- NFIT and SSDT in question are quite self-contained, i.e. they do not refer to other ACPI tables and not conflict with existing guest ACPI tables in Xen. Therefore, it is safe to copy them from QEMU and append to existing guest ACPI tables.Quoted 4 lines
How is this not conflicting being guaranteed? In particular I don't see how tables containing AML code and coming from different sources won't possibly cause ACPI name space collisions.
Quoted 6 lines
Really there is no effective mechanism to avoid ACPI name space collisions (and other kinds of conflicts) between ACPI tables loaded from QEMU and ACPI tables built by hvmloader. Because which ACPI tables are loaded is determined by developers, IMO it's developers' responsibility to avoid any collisions and conflicts with existing ACPI tables.
Right, but this needs to be spelled out and settled on at design time (i.e. now), rather leaving things unspecified, awaiting the first clash.
Quoted 8 lines
Quoted 2 lines
So that means if no collision-proof mechanism is introduced, Xen should not trust any passed-in ACPI tables and should build them by itself?
Basically yes, albeit collision-proof may be too much to demand. Simply separating name spaces (for hvmloader and qemu to have their own sub-spaces) would be sufficient imo. We should trust ourselves to play by such a specification.
Quoted 4 lines
I don't quite understand 'separating name spaces'. Do you mean, for example, if both hvmloader and qemu want to put a namespace device under \_SB, they could be put in different sub-scopes under \_SB? But it does not work for Linux at least.
Aiui just the leaf names matter for sufficient separation, i.e. recurring sub-scopes should not be a problem.
Quoted 9 lines
Anyway, we may avoid some conflicts between ACPI tables/objects by restricting which tables and objects can be passed from QEMU to Xen:
(1) For ACPI tables, xen does not accept those built by itself, e.g. DSDT and SSDT.
(2) xen does not accept ACPI tables for devices that are not attached to a domain, e.g. if NFIT cannot be passed if a domain does not have vNVDIMM.
(3) For ACPI objects, xen only accepts namespace devices and requires their names does not conflict with existing ones provided by Xen.
Quoted 3 lines
And how do you imagine to enforce this without parsing the handed AML? (Remember there's no AML parser in hvmloader.)
As I proposed in last reply, instead of passing an entire ACPI object, QEMU passes the device name and the AML code under the AML device entry separately. Because the name is explicitly given, no AML parser is needed in hvmloader.
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 13 lines
Quoted 1 line
Quoted 1 line · On 29.02.16 at 10:45, <[email protected]> wrote:
Quoted 11 lines · Jan Beulich
Quoted 10 lines
Quoted 1 line
Quoted 1 line · On 28.02.16 at 15:48, <[email protected]> wrote:
Anyway, we may avoid some conflicts between ACPI tables/objects by restricting which tables and objects can be passed from QEMU to Xen:
(1) For ACPI tables, xen does not accept those built by itself, e.g. DSDT and SSDT.
(2) xen does not accept ACPI tables for devices that are not attached to a domain, e.g. if NFIT cannot be passed if a domain does not have vNVDIMM.
(3) For ACPI objects, xen only accepts namespace devices and requires their names does not conflict with existing ones provided by Xen.
Quoted 7 lines
Quoted 2 lines
And how do you imagine to enforce this without parsing the handed AML? (Remember there's no AML parser in hvmloader.)
As I proposed in last reply, instead of passing an entire ACPI object, QEMU passes the device name and the AML code under the AML device entry separately. Because the name is explicitly given, no AML parser is needed in hvmloader.
I must not only have missed that proposal, but I also don't see how you mean this to work: Are you suggesting for hvmloader to construct valid AML from the passed in blob? Or are you instead considering to pass redundant information (name once given explicitly and once embedded in the AML blob), allowing the two to be out of sync?
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 21 lines · Jan Beulich
Quoted 13 lines
Quoted 1 line
Quoted 1 line · On 29.02.16 at 10:45, <[email protected]> wrote:
Quoted 11 lines · Jan Beulich
Quoted 10 lines
Quoted 1 line
Quoted 1 line · On 28.02.16 at 15:48, <[email protected]> wrote:
Anyway, we may avoid some conflicts between ACPI tables/objects by restricting which tables and objects can be passed from QEMU to Xen:
(1) For ACPI tables, xen does not accept those built by itself, e.g. DSDT and SSDT.
(2) xen does not accept ACPI tables for devices that are not attached to a domain, e.g. if NFIT cannot be passed if a domain does not have vNVDIMM.
(3) For ACPI objects, xen only accepts namespace devices and requires their names does not conflict with existing ones provided by Xen.Quoted 7 lines
Quoted 2 lines
And how do you imagine to enforce this without parsing the handed AML? (Remember there's no AML parser in hvmloader.)
As I proposed in last reply, instead of passing an entire ACPI object, QEMU passes the device name and the AML code under the AML device entry separately. Because the name is explicitly given, no AML parser is needed in hvmloader.
Quoted 7 lines
I must not only have missed that proposal, but I also don't see how you mean this to work: Are you suggesting for hvmloader to construct valid AML from the passed in blob? Or are you instead considering to pass redundant information (name once given explicitly and once embedded in the AML blob), allowing the two to be out of sync?
I mean the former one.
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 23 lines
Quoted 1 line
Quoted 1 line · On 29.02.16 at 12:52, <[email protected]> wrote:
Quoted 21 lines · Jan Beulich
Quoted 20 lines
Quoted 1 line
Quoted 1 line · On 29.02.16 at 10:45, <[email protected]> wrote:
Quoted 11 lines · Jan Beulich
Quoted 10 lines
Quoted 1 line
Quoted 1 line · On 28.02.16 at 15:48, <[email protected]> wrote:
Anyway, we may avoid some conflicts between ACPI tables/objects by restricting which tables and objects can be passed from QEMU to Xen:
(1) For ACPI tables, xen does not accept those built by itself, e.g. DSDT and SSDT.
(2) xen does not accept ACPI tables for devices that are not attached to a domain, e.g. if NFIT cannot be passed if a domain does not have vNVDIMM.
(3) For ACPI objects, xen only accepts namespace devices and requires their names does not conflict with existing ones provided by Xen.Quoted 2 lines
And how do you imagine to enforce this without parsing the handed AML? (Remember there's no AML parser in hvmloader.)
As I proposed in last reply, instead of passing an entire ACPI object, QEMU passes the device name and the AML code under the AML device entry separately. Because the name is explicitly given, no AML parser is needed in hvmloader.
Quoted 8 lines
Quoted 6 lines
I must not only have missed that proposal, but I also don't see how you mean this to work: Are you suggesting for hvmloader to construct valid AML from the passed in blob? Or are you instead considering to pass redundant information (name once given explicitly and once embedded in the AML blob), allowing the two to be out of sync?
I mean the former one.
Which will involve adding how much new code to it?
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 30 lines · Jan Beulich
Quoted 30 lines
Quoted 1 line
Quoted 1 line · On 29.02.16 at 12:52, <[email protected]> wrote:
Quoted 27 lines · Jan Beulich
Quoted 13 lines
Quoted 1 line
Quoted 1 line · On 29.02.16 at 10:45, <[email protected]> wrote:
Quoted 11 lines · Jan Beulich
Quoted 10 lines
Quoted 1 line
Quoted 1 line · On 28.02.16 at 15:48, <[email protected]> wrote:
Anyway, we may avoid some conflicts between ACPI tables/objects by restricting which tables and objects can be passed from QEMU to Xen:
(1) For ACPI tables, xen does not accept those built by itself, e.g. DSDT and SSDT.
(2) xen does not accept ACPI tables for devices that are not attached to a domain, e.g. if NFIT cannot be passed if a domain does not have vNVDIMM.
(3) For ACPI objects, xen only accepts namespace devices and requires their names does not conflict with existing ones provided by Xen.Quoted 7 lines
Quoted 2 lines
And how do you imagine to enforce this without parsing the handed AML? (Remember there's no AML parser in hvmloader.)
As I proposed in last reply, instead of passing an entire ACPI object, QEMU passes the device name and the AML code under the AML device entry separately. Because the name is explicitly given, no AML parser is needed in hvmloader.
I must not only have missed that proposal, but I also don't see how you mean this to work: Are you suggesting for hvmloader to construct valid AML from the passed in blob? Or are you instead considering to pass redundant information (name once given explicitly and once embedded in the AML blob), allowing the two to be out of sync?
Quoted 4 lines
Quoted 1 line
I mean the former one.
Which will involve adding how much new code to it?
Because hvmloader only accepts AML device rather than arbitrary objects, only code that builds the outmost part of AML device is needed. In ACPI spec, an AML device is defined as
DefDevice := DeviceOp PkgLength NameString ObjectList
hvmloader only needs to build the first 3 terms, while the last one is passed from qemu.
Haozhong
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Haozhong Zhang writes ("Re: [RFC Design Doc] Add vNVDIMM support for Xen"):
Quoted 9 lines · Jan Beulich
Quoted 1 line
Which will involve adding how much new code to it?
Because hvmloader only accepts AML device rather than arbitrary objects, only code that builds the outmost part of AML device is needed. In ACPI spec, an AML device is defined as
DefDevice := DeviceOp PkgLength NameString ObjectList
hvmloader only needs to build the first 3 terms, while the last one is passed from qemu.
Jan, is this a satisfactory answer ?
Ian.
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 5 lines
Quoted 1 line
Quoted 1 line · On 01.03.16 at 14:51, <[email protected]> wrote:
Haozhong Zhang writes ("Re: [RFC Design Doc] Add vNVDIMM support for Xen"):
Quoted 3 lines · Jan Beulich
Quoted 1 line
Which will involve adding how much new code to it?
Quoted 8 lines
Quoted 6 lines
Because hvmloader only accepts AML device rather than arbitrary objects, only code that builds the outmost part of AML device is needed. In ACPI spec, an AML device is defined as
DefDevice := DeviceOp PkgLength NameString ObjectList
hvmloader only needs to build the first 3 terms, while the last one is passed from qemu.Jan, is this a satisfactory answer ?
Well, sort of yes, but subject to me seeing the actual code this converts to.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel