Skip to contentSkip to conversation

Some fabrics fixes

PATCH New Sagi Grimberg 2 participants 10 messages Aug 2, 2016 – Aug 3, 2016

Subsystems (3)
lore
Share & tools
lore

Sagi Grimberg

author maintainer
#0 lore raw

v2 cover Some fabrics fixes

A set of fixes to the nvme-rdma host driver. First two patches relate to bug reports from Steve Wise on dervice removal handling (and go together with Steve's iwcm patch set).

Next two patches remove redundant calls to nvme_remove_namespaces which is called from nvme_uninit_ctrl.

The last patch fixes the host behavior that it never shutdown the controller (wrong check on the controller state). Christoph, we can either go with this and change the behavior incrementally (currently we never shutdown the controller) or I can just remove the patch altogether.

Changes from v1:
- rearranged nvme ctrl remove to avoid code duplication
- added some change log info to rdma and loop uninit and shutdown reordering.
- collected some review tags

Sagi Grimberg (5):
nvme-rdma: Fix device removal handling
nvme-rdma: Remove duplicate call to nvme_remove_namespaces
nvme-rdma: Free the I/O tags when we delete the controller
nvme-loop: Remove duplicate call to nvme_remove_namespaces
nvme-rdma: Make sure to shutdown the controller if we can

 drivers/nvme/host/rdma.c   | 72 +++++++++++++++++++++++++---------------------
 drivers/nvme/target/loop.c |  4 +--
 2 files changed, 40 insertions(+), 36 deletions(-)
Signature · 1 line
1.9.1
author maintainer
#1 lore raw

PATCH v2 1/5 nvme-rdma: Fix device removal handling

Device removal sequence may have crashed because the controller (and admin queue space) was freed before we destroyed the admin queue resources. Thus we want to destroy the admin queue and only then queue controller deletion and wait for it to complete.

More specifically we:
1. own the controller deletion (make sure we are not competing with another deletion).
2. get rid of inflight reconnects if exists (which also destroy and create queues).
3. destroy the queue.
4. safely queue controller deletion (and wait for it to complete).

Reported-by Steve Wise <swise at opengridcomputing.com>
Signed-off-by Sagi Grimberg <sagi at grimberg.me>
Reviewed-by Christoph Hellwig <hch at lst.de>
---
 drivers/nvme/host/rdma.c | 41 +++++++++++++++++++++--------------------
 1 file changed, 21 insertions(+), 20 deletions(-)
drivers/nvme/host/rdma.c +21 -20
index 21ecbf3f3603..f391d67e4ee0 100644
@@ -169,7 +169,6 @@ MODULE_PARM_DESC(register_always,
 static int nvme_rdma_cm_handler(struct rdma_cm_id *cm_id,
 		struct rdma_cm_event *event);
 static void nvme_rdma_recv_done(struct ib_cq *cq, struct ib_wc *wc);
-static int __nvme_rdma_del_ctrl(struct nvme_rdma_ctrl *ctrl);
 
 /* XXX: really should move to a generic header sooner or later.. */
 static inline void put_unaligned_le24(u32 val, u8 *p)
@@ -1318,37 +1317,39 @@ out_destroy_queue_ib:
  * that caught the event. Since we hold the callout until the controller
  * deletion is completed, we'll deadlock if the controller deletion will
  * call rdma_destroy_id on this queue's cm_id. Thus, we claim ownership
- * of destroying this queue before-hand, destroy the queue resources
- * after the controller deletion completed with the exception of destroying
- * the cm_id implicitely by returning a non-zero rc to the callout.
+ * of destroying this queue before-hand, destroy the queue resources,
+ * then queue the controller deletion which won't destroy this queue and
+ * we destroy the cm_id implicitely by returning a non-zero rc to the callout.
  */
 static int nvme_rdma_device_unplug(struct nvme_rdma_queue *queue)
 {
 	struct nvme_rdma_ctrl *ctrl = queue->ctrl;
-	int ret, ctrl_deleted = 0;
+	int ret;
 
-	/* First disable the queue so ctrl delete won't free it */
-	if (!test_and_clear_bit(NVME_RDMA_Q_CONNECTED, &queue->flags))
-		goto out;
+	/* Own the controller deletion */
+	if (!nvme_change_ctrl_state(&ctrl->ctrl, NVME_CTRL_DELETING))
+		return 0;
 
-	/* delete the controller */
-	ret = __nvme_rdma_del_ctrl(ctrl);
-	if (!ret) {
-		dev_warn(ctrl->ctrl.device,
-			"Got rdma device removal event, deleting ctrl\n");
-		flush_work(&ctrl->delete_work);
+	dev_warn(ctrl->ctrl.device,
+		"Got rdma device removal event, deleting ctrl\n");
 
-		/* Return non-zero so the cm_id will destroy implicitly */
-		ctrl_deleted = 1;
+	/* Get rid of reconnect work if its running */
+	cancel_delayed_work_sync(&ctrl->reconnect_work);
 
+	/* Disable the queue so ctrl delete won't free it */
+	if (test_and_clear_bit(NVME_RDMA_Q_CONNECTED, &queue->flags)) {
 		/* Free this queue ourselves */
-		rdma_disconnect(queue->cm_id);
-		ib_drain_qp(queue->qp);
+		nvme_rdma_stop_queue(queue);
 		nvme_rdma_destroy_queue_ib(queue);
+
+		/* Return non-zero so the cm_id will destroy implicitly */
+		ret = 1;
 	}
 
-out:
-	return ctrl_deleted;
+	/* Queue controller deletion */
+	queue_work(nvme_rdma_wq, &ctrl->delete_work);
+	flush_work(&ctrl->delete_work);
+	return ret;
 }
 
 static int nvme_rdma_cm_handler(struct rdma_cm_id *cm_id,
Signature · 1 line
1.9.1
author maintainer
#2 lore raw

PATCH v2 2/5 nvme-rdma: Remove duplicate call to nvme_remove_namespaces

In reply to Sagi Grimberg

nvme_uninit_ctrl already does that for us. Note that we reordered nvme_rdma_shutdown_ctrl and nvme_uninit_ctrl, this is perfectly fine because we actually want ctrl uninit (aen, scan cancellation and namespaces removal) to happen before we shutdown the rdma resources.

Also, centralize the deletion work and the dead controller removal work code duplication into __nvme_rdma_shutdown_ctrl that accepts a shutdown boolean.

Signed-off-by Sagi Grimberg <sagi at grimberg.me>
---
 drivers/nvme/host/rdma.c | 17 ++++++++++-------
 1 file changed, 10 insertions(+), 7 deletions(-)
drivers/nvme/host/rdma.c +10 -7
index f391d67e4ee0..39330bd295d4 100644
@@ -1658,15 +1658,20 @@ static void nvme_rdma_shutdown_ctrl(struct nvme_rdma_ctrl *ctrl)
 	nvme_rdma_destroy_admin_queue(ctrl);
 }
 
+static void __nvme_rdma_remove_ctrl(struct nvme_rdma_ctrl *ctrl, bool shutdown)
+{
+	nvme_uninit_ctrl(&ctrl->ctrl);
+	if (shutdown)
+		nvme_rdma_shutdown_ctrl(ctrl);
+	nvme_put_ctrl(&ctrl->ctrl);
+}
+
 static void nvme_rdma_del_ctrl_work(struct work_struct *work)
 {
 	struct nvme_rdma_ctrl *ctrl = container_of(work,
 				struct nvme_rdma_ctrl, delete_work);
 
-	nvme_remove_namespaces(&ctrl->ctrl);
-	nvme_rdma_shutdown_ctrl(ctrl);
-	nvme_uninit_ctrl(&ctrl->ctrl);
-	nvme_put_ctrl(&ctrl->ctrl);
+	__nvme_rdma_remove_ctrl(ctrl, true);
 }
 
 static int __nvme_rdma_del_ctrl(struct nvme_rdma_ctrl *ctrl)
@@ -1699,9 +1704,7 @@ static void nvme_rdma_remove_ctrl_work(struct work_struct *work)
 	struct nvme_rdma_ctrl *ctrl = container_of(work,
 				struct nvme_rdma_ctrl, delete_work);
 
-	nvme_remove_namespaces(&ctrl->ctrl);
-	nvme_uninit_ctrl(&ctrl->ctrl);
-	nvme_put_ctrl(&ctrl->ctrl);
+	__nvme_rdma_remove_ctrl(ctrl, false);
 }
 
 static void nvme_rdma_reset_ctrl_work(struct work_struct *work)
Signature · 1 line
1.9.1
#3 lore raw

PATCH v2 2/5 nvme-rdma: Remove duplicate call to nvme_remove_namespaces

Quoted 9 lines · Sagi Grimberg

nvme_uninit_ctrl already does that for us. Note that we reordered nvme_rdma_shutdown_ctrl and nvme_uninit_ctrl, this is perfectly fine because we actually want ctrl uninit (aen, scan cancellation and namespaces removal) to happen before we shutdown the rdma resources.

Also, centralize the deletion work and the dead controller removal work code duplication into __nvme_rdma_shutdown_ctrl that accepts a shutdown boolean.

Looks fine:

Reviewed-by Christoph Hellwig <hch at lst.de>
author maintainer
#4 lore raw

PATCH v2 3/5 nvme-rdma: Free the I/O tags when we delete the controller

In reply to Sagi Grimberg

If we wait until we free the controller (free_ctrl) we might lose our rdma device without any notification while we still have open resources (tags mrs and dma mappings).

Instead, destroy the tags with their rdma resources once we delete the device and not when freeing it.

Note that we don't do that in nvme_rdma_shutdown_ctrl because controller reset uses it as well and we want to give active I/O a chance to complete successfully.

Signed-off-by Sagi Grimberg <sagi at grimberg.me>
---
 drivers/nvme/host/rdma.c | 12 +++++++-----
 1 file changed, 7 insertions(+), 5 deletions(-)
drivers/nvme/host/rdma.c +7 -5
index 39330bd295d4..f31915696421 100644
@@ -686,11 +686,6 @@ static void nvme_rdma_free_ctrl(struct nvme_ctrl *nctrl)
 	list_del(&ctrl->list);
 	mutex_unlock(&nvme_rdma_ctrl_mutex);
 
-	if (ctrl->ctrl.tagset) {
-		blk_cleanup_queue(ctrl->ctrl.connect_q);
-		blk_mq_free_tag_set(&ctrl->tag_set);
-		nvme_rdma_dev_put(ctrl->device);
-	}
 	kfree(ctrl->queues);
 	nvmf_free_options(nctrl->opts);
 free_ctrl:
@@ -1663,6 +1658,13 @@ static void __nvme_rdma_remove_ctrl(struct nvme_rdma_ctrl *ctrl, bool shutdown)
 	nvme_uninit_ctrl(&ctrl->ctrl);
 	if (shutdown)
 		nvme_rdma_shutdown_ctrl(ctrl);
+
+	if (ctrl->ctrl.tagset) {
+		blk_cleanup_queue(ctrl->ctrl.connect_q);
+		blk_mq_free_tag_set(&ctrl->tag_set);
+		nvme_rdma_dev_put(ctrl->device);
+	}
+
 	nvme_put_ctrl(&ctrl->ctrl);
 }
 
Signature · 1 line
1.9.1
#5 lore raw

PATCH v2 3/5 nvme-rdma: Free the I/O tags when we delete the controller

Quoted 4 lines · Sagi Grimberg

If we wait until we free the controller (free_ctrl) we might lose our rdma device without any notification while we still have open resources (tags mrs and dma mappings).

Quoted 8 lines

Instead, destroy the tags with their rdma resources once we delete the device and not when freeing it.

Note that we don't do that in nvme_rdma_shutdown_ctrl because controller reset uses it as well and we want to give active I/O a chance to complete successfully.

Signed-off-by Sagi Grimberg <sagi at grimberg.me>

Looks fine:

Reviewed-by Christoph Hellwig <hch at lst.de>
author maintainer
#6 lore raw

PATCH v2 4/5 nvme-loop: Remove duplicate call to nvme_remove_namespaces

In reply to Sagi Grimberg

nvme_uninit_ctrl already does that for us. Note that we reordered nvme_loop_shutdown_ctrl with nvme_uninit_ctrl but its safe because we want controller uninit to happen before we shutdown the transport resources.

Signed-off-by Sagi Grimberg <sagi at grimberg.me>
---
 drivers/nvme/target/loop.c | 4 +---
 1 file changed, 1 insertion(+), 3 deletions(-)
drivers/nvme/target/loop.c +1 -3
index 94e782987cc9..7affd40a6b33 100644
@@ -414,9 +414,8 @@ static void nvme_loop_del_ctrl_work(struct work_struct *work)
 	struct nvme_loop_ctrl *ctrl = container_of(work,
 				struct nvme_loop_ctrl, delete_work);
 
-	nvme_remove_namespaces(&ctrl->ctrl);
-	nvme_loop_shutdown_ctrl(ctrl);
 	nvme_uninit_ctrl(&ctrl->ctrl);
+	nvme_loop_shutdown_ctrl(ctrl);
 	nvme_put_ctrl(&ctrl->ctrl);
 }
 
@@ -501,7 +500,6 @@ out_free_queues:
 	nvme_loop_destroy_admin_queue(ctrl);
 out_disable:
 	dev_warn(ctrl->ctrl.device, "Removing after reset failure\n");
-	nvme_remove_namespaces(&ctrl->ctrl);
 	nvme_uninit_ctrl(&ctrl->ctrl);
 	nvme_put_ctrl(&ctrl->ctrl);
 }
Signature · 1 line
1.9.1
#7 lore raw

PATCH v2 4/5 nvme-loop: Remove duplicate call to nvme_remove_namespaces

Quoted 6 lines · Sagi Grimberg

nvme_uninit_ctrl already does that for us. Note that we reordered nvme_loop_shutdown_ctrl with nvme_uninit_ctrl but its safe because we want controller uninit to happen before we shutdown the transport resources.

Signed-off-by Sagi Grimberg <sagi at grimberg.me>

Looks fine,

Reviewed-by Christoph Hellwig <hch at lst.de>
author maintainer
#8 lore raw

PATCH v2 5/5 nvme-rdma: Make sure to shutdown the controller if we can

In reply to Sagi Grimberg

Relying on ctrl state in nvme_rdma_shutdown_ctrl is wrong because it will never be NVME_CTRL_LIVE (delete_ctrl or reset_ctrl invoked it).

Instead, check that the admin queue is connected. Note that it is safe because we can never see a copmeting thread trying to destroy the admin queue (reset or delete controller).

Signed-off-by Sagi Grimberg <sagi at grimberg.me>
---
 drivers/nvme/host/rdma.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/nvme/host/rdma.c +1 -1
index f31915696421..ef821592b791 100644
@@ -1644,7 +1644,7 @@ static void nvme_rdma_shutdown_ctrl(struct nvme_rdma_ctrl *ctrl)
 		nvme_rdma_free_io_queues(ctrl);
 	}
 
-	if (ctrl->ctrl.state == NVME_CTRL_LIVE)
+	if (test_bit(NVME_RDMA_Q_CONNECTED, &ctrl->queues[0].flags))
 		nvme_shutdown_ctrl(&ctrl->ctrl);
 
 	blk_mq_stop_hw_queues(ctrl->ctrl.admin_q);
Signature · 1 line
1.9.1
#9 lore raw

PATCH v2 5/5 nvme-rdma: Make sure to shutdown the controller if we can

Quoted 8 lines · Sagi Grimberg

Relying on ctrl state in nvme_rdma_shutdown_ctrl is wrong because it will never be NVME_CTRL_LIVE (delete_ctrl or reset_ctrl invoked it).

Instead, check that the admin queue is connected. Note that it is safe because we can never see a copmeting thread trying to destroy the admin queue (reset or delete controller).

Signed-off-by Sagi Grimberg <sagi at grimberg.me>

Looks fine,

Reviewed-by Christoph Hellwig <hch at lst.de>