admin-cmd: Added smart-log command support.

PATCH New Chaitanya Kulkarni 4 participants 6 messages Sep 1, 2016 – Sep 20, 2016

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH 1/1 admin-cmd: Added smart-log command support.

This patch implements the support for smart-log command (NVM Express 1.2.1-section 5.10.1.2 SMART / Health Information (Log Identifier 02h)) on the target for NVMe over Fabric.

In current implementation host can retrieve following statistics:-
1. Data Units Read.
2. Data Units Written.
3. Host Read Commands.
4. Host Write Commands.

Signed-off-by Chaitanya Kulkarni <ckulkarnilinux at gmail.com>
---
 drivers/nvme/target/admin-cmd.c | 88 +++++++++++++++++++++++++++++++++++++++++
 1 file changed, 88 insertions(+)
drivers/nvme/target/admin-cmd.c +88 -0
index 47c564b..7ab9c93 100644
@@ -14,6 +14,7 @@
 #define pr_fmt(fmt) KBUILD_MODNAME ": " fmt
 #include <linux/module.h>
 #include <generated/utsrelease.h>
+#include <asm/unaligned.h>
 #include "nvmet.h"
 
 u32 nvmet_get_log_page_len(struct nvme_command *cmd)
@@ -29,8 +30,84 @@ u32 nvmet_get_log_page_len(struct nvme_command *cmd)
 	return len;
 }
 
+static u16 nvmet_get_smart_log_nsid(struct nvmet_req *req,
+		struct nvme_smart_log *slog)
+{
+	u16 status;
+	struct nvmet_ns *ns;
+	u64 host_reads, host_writes, data_units_read, data_units_written;
+
+	status = NVME_SC_SUCCESS;
+	ns = nvmet_find_namespace(req->sq->ctrl, req->cmd->get_log_page.nsid);
+	if (!ns) {
+		status = NVME_SC_INVALID_NS;
+		pr_err("nvmet : Counld not find namespace id : %d\n",
+				le32_to_cpu(req->cmd->get_log_page.nsid));
+		goto out;
+	}
+
+	host_reads = part_stat_read(ns->bdev->bd_part, ios[READ]);
+	data_units_read = part_stat_read(ns->bdev->bd_part, sectors[READ]);
+	host_writes = part_stat_read(ns->bdev->bd_part, ios[WRITE]);
+	data_units_written = part_stat_read(ns->bdev->bd_part, sectors[WRITE]);
+
+	put_unaligned_le64(host_reads, &slog->host_reads[0]);
+	put_unaligned_le64(data_units_read, &slog->data_units_read[0]);
+	put_unaligned_le64(host_writes, &slog->host_writes[0]);
+	put_unaligned_le64(data_units_written, &slog->data_units_written[0]);
+	nvmet_put_namespace(ns);
+out:
+	return status;
+}
+
+static u16 nvmet_get_smart_log_all(struct nvmet_req *req,
+		struct nvme_smart_log *slog)
+{
+	u16 status;
+	u64 host_reads = 0, host_writes = 0;
+	u64 data_units_read = 0, data_units_written = 0;
+	struct nvmet_ns *ns;
+	struct nvmet_ctrl *ctrl;
+
+	status = NVME_SC_SUCCESS;
+	ctrl = req->sq->ctrl;
+
+	rcu_read_lock();
+	list_for_each_entry_rcu(ns, &ctrl->subsys->namespaces, dev_link) {
+		host_reads += part_stat_read(ns->bdev->bd_part, ios[READ]);
+		data_units_read +=
+			part_stat_read(ns->bdev->bd_part, sectors[READ]);
+		host_writes += part_stat_read(ns->bdev->bd_part, ios[WRITE]);
+		data_units_written +=
+			part_stat_read(ns->bdev->bd_part, sectors[WRITE]);
+
+	}
+	rcu_read_unlock();
+
+	put_unaligned_le64(host_reads, &slog->host_reads[0]);
+	put_unaligned_le64(data_units_read, &slog->data_units_read[0]);
+	put_unaligned_le64(host_writes, &slog->host_writes[0]);
+	put_unaligned_le64(data_units_written, &slog->data_units_written[0]);
+
+	return status;
+}
+
+static u16 nvmet_get_smart_log(struct nvmet_req *req,
+		struct nvme_smart_log *slog)
+{
+	u16 status;
+
+	WARN_ON(req == NULL || slog == NULL);
+	if (req->cmd->get_log_page.nsid == 0xFFFFFFFF)
+		status = nvmet_get_smart_log_all(req, slog);
+	else
+		status = nvmet_get_smart_log_nsid(req, slog);
+	return status;
+}
+
 static void nvmet_execute_get_log_page(struct nvmet_req *req)
 {
+	struct nvme_smart_log *smart_log;
 	size_t data_len = nvmet_get_log_page_len(req->cmd);
 	void *buf;
 	u16 status = 0;
@@ -59,6 +136,16 @@ static void nvmet_execute_get_log_page(struct nvmet_req *req)
 		 * available (e.g. units or commands read/written) those aren't
 		 * persistent over power loss.
 		 */
+		if (data_len != sizeof(*smart_log)) {
+			status = NVME_SC_INTERNAL;
+			goto err;
+		}
+		smart_log = buf;
+		status = nvmet_get_smart_log(req, smart_log);
+		if (status) {
+			memset(buf, '\0', data_len);
+			goto err;
+		}
 		break;
 	case 0x03:
 		/*
@@ -73,6 +160,7 @@ static void nvmet_execute_get_log_page(struct nvmet_req *req)
 
 	status = nvmet_copy_to_sgl(req, 0, buf, data_len);
 
+err:
 	kfree(buf);
 out:
 	nvmet_req_complete(req, status);
Signature · 1 line
1.9.1
maintainer
#1 lore raw

PATCH 1/1 admin-cmd: Added smart-log command support.

Quoted 36 lines
drivers/nvme/target/admin-cmd.c +20 -0
index 47c564b..7ab9c93 100644
@@ -14,6 +14,7 @@
 #define pr_fmt(fmt) KBUILD_MODNAME ": " fmt
 #include <linux/module.h>
 #include <generated/utsrelease.h>
+#include <asm/unaligned.h>
 #include "nvmet.h"
 
 u32 nvmet_get_log_page_len(struct nvme_command *cmd)
@@ -29,8 +30,84 @@ u32 nvmet_get_log_page_len(struct nvme_command *cmd)
 	return len;
 }
 
+static u16 nvmet_get_smart_log_nsid(struct nvmet_req *req,
+		struct nvme_smart_log *slog)
+{
+	u16 status;
+	struct nvmet_ns *ns;
+	u64 host_reads, host_writes, data_units_read, data_units_written;
+
+	status = NVME_SC_SUCCESS;
+	ns = nvmet_find_namespace(req->sq->ctrl, req->cmd->get_log_page.nsid);
+	if (!ns) {
+		status = NVME_SC_INVALID_NS;
+		pr_err("nvmet : Counld not find namespace id : %d\n",
+				le32_to_cpu(req->cmd->get_log_page.nsid));
+		goto out;
+	}
+
+	host_reads = part_stat_read(ns->bdev->bd_part, ios[READ]);
+	data_units_read = part_stat_read(ns->bdev->bd_part, sectors[READ]);
+	host_writes = part_stat_read(ns->bdev->bd_part, ios[WRITE]);

drivers/nvme/target/admin-cmd.c u32 nvmet_get_log_page_len(struct nvme_command *cmd) · line 61

Quoted 10 lines
drivers/nvme/target/admin-cmd.c +10 -0
+	data_units_written = part_stat_read(ns->bdev->bd_part, sectors[WRITE]);
+
+	put_unaligned_le64(host_reads, &slog->host_reads[0]);
+	put_unaligned_le64(data_units_read, &slog->data_units_read[0]);
+	put_unaligned_le64(host_writes, &slog->host_writes[0]);
+	put_unaligned_le64(data_units_written, &slog->data_units_written[0]);
+	nvmet_put_namespace(ns);
+out:
+	return status;
+}

Given that we don't own the namespaces, I'm wandering if this is the correct way to do this... I'm not at all convinced that having something else reading/writing to the blkdevs other than nvmf is a valid/useful use-case but in this situation we won't get correct log information (or at least the semantics is wrong).

Should we maintain these statistics in the target stack instead?

#2 lore raw

PATCH 1/1 admin-cmd: Added smart-log command support.

Quoted 7 lines · Sagi Grimberg

Given that we don't own the namespaces, I'm wandering if this is the correct way to do this... I'm not at all convinced that having something else reading/writing to the blkdevs other than nvmf is a valid/useful use-case but in this situation we won't get correct log information (or at least the semantics is wrong).

Should we maintain these statistics in the target stack instead?

What's the problem with including possible local I/O? Having to maintain another set of counters, including atomics in the fast path or complex per-cpu infrastructure is something I'd rather avoid.

maintainer
#3 lore raw

PATCH 1/1 admin-cmd: Added smart-log command support.

Quoted 7 lines
Quoted 7 lines

Given that we don't own the namespaces, I'm wandering if this is the correct way to do this... I'm not at all convinced that having something else reading/writing to the blkdevs other than nvmf is a valid/useful use-case but in this situation we won't get correct log information (or at least the semantics is wrong).

Quoted 5 lines
Quoted 1 line

Should we maintain these statistics in the target stack instead?

What's the problem with including possible local I/O? Having to maintain another set of counters, including atomics in the fast path or complex per-cpu infrastructure is something I'd rather avoid.

I don't want it either. But I think that the semantics of the smart log info is different, the question is are we ok with it?

#5 lore raw

PATCH 1/1 admin-cmd: Added smart-log command support.

Quoted 3 lines · Sagi Grimberg

Queued this up for 4.9,

Christoph, can I get your reviewed-by?

sure:

Reviewed-by Christoph Hellwig <hch at lst.de>