sbs-battery: make writes to ManufacturerAccess optional
PATCH 1/1 sbs-battery: make writes to ManufacturerAccess optional
According to the Smart Battery Data Specification, the use of ManufacturerAcess (register 0x0) is implementation-defined. It appears that some batteries use writes to this register in order to implement certain functionality, but others may simply NAK all writes to it. As a result, write failures to ManufacturerAccess should not be used as an indicator of battery presence, nor as a failure to enter sleep mode.
The failed write access was seen with SANYO AP13J3K.
--- drivers/power/sbs-battery.c | 29 +++++++++++++++-------------- 1 file changed, 15 insertions(+), 14 deletions(-)
drivers/power/sbs-battery.c +15 -14
@@ -313,21 +313,22 @@ static int sbs_get_battery_presence_and_health(return ret; } -/* Write to ManufacturerAccess with -* ManufacturerAccess command and then -* read the status */ - ret =sbs_write_word_data (client, sbs_data[REG_MANUFACTURER_DATA ].addr, -MANUFACTURER_ACCESS_STATUS ); +/* +* Write to ManufacturerAccess with ManufacturerAccess command +* and then read the status. Do not check for error on the write +* since not all batteries implement write access to this command, +* while others mandate it. +*/ +sbs_write_word_data (client, sbs_data[REG_MANUFACTURER_DATA ].addr, +MANUFACTURER_ACCESS_STATUS ); + + ret =sbs_read_word_data (client, sbs_data[REG_MANUFACTURER_DATA ].addr);if (ret <0 ) {if (psp ==POWER_SUPPLY_PROP_PRESENT ) val->intval =0 ;/* battery removed */ return ret; } - ret =sbs_read_word_data (client, sbs_data[REG_MANUFACTURER_DATA ].addr); -if (ret <0 ) -return ret; -if (ret < sbs_data[REG_MANUFACTURER_DATA ].min_value || ret > sbs_data[REG_MANUFACTURER_DATA ].max_value) { val->intval =0 ;
@@ -950,16 +951,16 @@ static int sbs_suspend(struct device *dev) {struct i2c_client *client =to_i2c_client (dev);struct sbs_info *chip =i2c_get_clientdata (client); -s32 ret;if (chip->poll_time >0 )cancel_delayed_work_sync (&chip->work); -/* write to manufacturer access with sleep command */ - ret =sbs_write_word_data (client, sbs_data[REG_MANUFACTURER_DATA ].addr, +/* +* Write to manufacturer access with sleep command. +* Support is manufacturer dependend, so ignore errors. +*/ +sbs_write_word_data (client, sbs_data[REG_MANUFACTURER_DATA ].addr,MANUFACTURER_ACCESS_SLEEP ); -if (chip->is_present && ret <0 ) -return ret;return 0 ; }
Signature · 1 line
2.5.0
Hi,
Quoted 8 lines · Guenter Roeck
According to the Smart Battery Data Specification, the use of ManufacturerAcess (register
0x0) is implementation-defined. It appears that some batteries use writes to this register in order to implement certain functionality, but others may simply NAK all writes to it. As a result, write failures to ManufacturerAccess should not be used as an indicator of battery presence, nor as a failure to enter sleep mode.
Quoted 4 lines
The failed write access was seen with SANYO AP13J3K.
Cc Brian Norris <[email protected]>Signed-off-by Guenter Roeck <[email protected]>
Thanks, queued.
-- Sebastian