x86: clarify shadow paging Dom0 support
PATCH 1/1 x86: clarify shadow paging Dom0 support
Classic PV shadow paging Dom0 has been broken for years, and can't possibly be configured after 4045953.
PVH shadow paging Dom0 should still be possible.
Change the code and documentation to clarify that.
---
Cc: Jan Beulich <[email protected]>
Cc: Andrew Cooper <[email protected]>
Cc: Tim Deegan <[email protected]>
Cc: George Dunlap <[email protected]>
Cc: Roger Pau Monné <[email protected]>
--- docs/misc/xen-command-line.markdown | 8 ++------ xen/arch/x86/dom0_build.c | 4 +++- xen/arch/x86/pv/dom0_build.c | 5 ----- 3 files changed, 5 insertions(+), 12 deletions(-)
docs/misc/xen-command-line.markdown +2 -6
@@ -652,11 +652,6 @@ restrictions set up here. Note that the values to be specified here are ACPI PXM ones, not Xen internal node numbers. `relaxed` sets up vCPU affinities to prefer but be not limited to the specified node(s). -### dom0\_shadow -> `= <boolean>` - -This option is deprecated, please use `dom0=shadow` instead. - ### dom0\_vcpus\_pin > `= <boolean>`
@@ -679,7 +674,8 @@ Flag that makes a dom0 boot in PVHv2 mode. > Default: `false` -Flag that makes a dom0 use shadow paging. +Flag that makes a dom0 use shadow paging. Only works when "pvh" is +enabled. ### dtuart (ARM) > `= path [:options]`
xen/arch/x86/dom0_build.c +3 -1
@@ -174,7 +174,6 @@ struct vcpu *__init alloc_dom0_vcpu0(struct domain *dom0)#ifdef CONFIG_SHADOW_PAGING bool __initdata opt_dom0_shadow; -boolean_param ("dom0_shadow" , opt_dom0_shadow);#endif bool __initdata dom0_pvh;
@@ -203,6 +202,9 @@ static void __init parse_dom0_param(char *s) s = ss +1 ; }while ( ss ); + +if ( opt_dom0_shadow && !dom0_pvh ) +panic ("Shadow paging Dom0 only works in PVH mode" ); }custom_param ("dom0" , parse_dom0_param);
xen/arch/x86/pv/dom0_build.c +0 -5
@@ -870,11 +870,6 @@ int __init dom0_construct_pv(struct domain *d, regs->rsi = vstartinfo_start; regs->eflags =X86_EFLAGS_IF ; -#ifdef CONFIG_SHADOW_PAGING -if ( opt_dom0_shadow &&paging_enable (d, PG_SH_enable) ==0 ) -paging_update_paging_modes (v); -#endif -if (test_bit (XENFEAT_supervisor_mode_kernel, parms.f_required) )panic ("Dom0 requires supervisor-mode execution" );
Signature · 7 lines
2.11.0 _______________________________________________ Xen-devel mailing list [email protected] https://lists.xen.org/xen-devel
Quoted 8 lines · Wei Liu
Classic PV shadow paging Dom0 has been broken for years, and can't possibly be configured after 4045953.
PVH shadow paging Dom0 should still be possible.
Change the code and documentation to clarify that.
Signed-off-by Wei Liu <[email protected]>
With one minor nit, AFAIK the need_paging check in dom0_compute_nr_pages can be simplified to:
need_paging = is_hvm_domain(d) && (!iommu_hap_pt_share || !paging_mode_hap(d));
Roger.
_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel
xen/arch/x86/dom0_build.c static void __init parse_dom0_param(char *s) · line 207
Quoted 8 lines
Quoted 1 line
Quoted 1 line · On 27.03.17 at 13:31, <[email protected]> wrote:
xen/arch/x86/dom0_build.c +3
-0@@ -203,6 +202,9 @@ static void __init parse_dom0_param(char *s) s = ss +1 ; }while ( ss ); + +if ( opt_dom0_shadow && !dom0_pvh ) +panic ("Shadow paging Dom0 only works in PVH mode" );
Tis is too early - option parsing happens before serial and video have been set up. This should be moved to somewhere early in Dom0 setup.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel