regulator: core: Only propagate voltage changes to if it can change voltages

PATCH In review Mark Brown 2 participants 6 messages Apr 13, 2017 – Apr 14, 2017 Voltage and current regulator framework

lore
Share & tools
lore

Mark Brown

author maintainer
#0 lore raw

PATCH 1/2 regulator: core: Only propagate voltage changes to if it can change voltages

When we are propagating voltage changes to parent regulators don't bother if the parent does not have permission to change voltages. This simplifies error checking in the function for cases where the regulator lacks some of the voltage operations.

---

Untested.

 drivers/regulator/core.c | 6 ++++--
 1 file changed, 4 insertions(+), 2 deletions(-)
drivers/regulator/core.c +4 -2
index 82205cc5daa7..2b464a286451 100644
@@ -2959,8 +2959,10 @@ static int regulator_set_voltage_unlocked(struct regulator *regulator,
 	if (ret < 0)
 		goto out2;
 
-	if (rdev->supply && (rdev->desc->min_dropout_uV ||
-				!rdev->desc->ops->get_voltage)) {
+	if (rdev->supply &&
+	    regulator_ops_is_valid(rdev->supply->rdev,
+				   REGULATOR_CHANGE_VOLTAGE) &&
+	    (rdev->desc->min_dropout_uV || !rdev->desc->ops->get_voltage)) {
 		int current_supply_uV;
 		int selector;
 
Signature · 1 line
2.11.0
author maintainer
#1 lore raw

PATCH 2/2 regulator: core: Allow dummy regulators for supplies

Rather than just not resolving the supply when there is explicitly no supply mapping fall through and allow a dummy supply to be substituted.

---
 drivers/regulator/core.c | 8 --------
 1 file changed, 8 deletions(-)
drivers/regulator/core.c +0 -8
index 2b464a286451..047ada74aa4a 100644
@@ -1533,14 +1533,6 @@ static int regulator_resolve_supply(struct regulator_dev *rdev)
 	if (IS_ERR(r)) {
 		ret = PTR_ERR(r);
 
-		if (ret == -ENODEV) {
-			/*
-			 * No supply was specified for this regulator and
-			 * there will never be one.
-			 */
-			return 0;
-		}
-
 		/* Did the lookup explicitly defer for us? */
 		if (ret == -EPROBE_DEFER)
 			return ret;
Signature · 1 line
2.11.0
Tested-by Reviewed-by on v1 1/2
#3 lore raw
In reply to Mark Brown
Quoted 11 lines · Mark Brown

When we are propagating voltage changes to parent regulators don't bother if the parent does not have permission to change voltages. This simplifies error checking in the function for cases where the regulator lacks some of the voltage operations.

---

Untested.

Thanks for the fix.

Regards
Dong Aisheng

author maintainer
#4 lore raw

Applied "regulator: core: Only propagate voltage changes to if it can change voltages" to the regulator tree

In reply to Mark Brown

The patch

regulator: core: Only propagate voltage changes to if it can change voltages

has been applied to the regulator tree at

git://git.kernel.org/pub/scm/linux/kernel/git/broonie/regulator.git

All being well this means that it will be integrated into the linux-next tree (usually sometime in the next 24 hours) and sent to Linus during the next merge window (or sooner if it is a bug fix), however if problems are discovered then the patch may be dropped or reverted.

You may get further e-mails resulting from automated or manual testing and review of the tree, please engage with people reporting problems and send followup patches addressing any issues that are reported if needed.

If any updates are required or you are submitting further changes they should be sent as incremental updates against current git, existing patches will not be replaced.

Please add any relevant lists and maintainers to the CCs when replying to this mail.

Thanks,
Mark

Quoted 1 line

From c8b2a4b5f2ab769d921668c2e844a8b78ca0bcd4 Mon Sep 17 00:00:00 2001

From: Mark Brown <[email protected]>
Date: Thu, 13 Apr 2017 18:36:59 +0100
Subject: [PATCH] regulator: core: Only propagate voltage changes to if it can
change voltages

When we are propagating voltage changes to parent regulators don't bother if the parent does not have permission to change voltages. This simplifies error checking in the function for cases where the regulator lacks some of the voltage operations.

---
 drivers/regulator/core.c | 6 ++++--
 1 file changed, 4 insertions(+), 2 deletions(-)
drivers/regulator/core.c +4 -2
index 04baac9a165b..33776bf5d9b4 100644
@@ -2921,8 +2921,10 @@ static int regulator_set_voltage_unlocked(struct regulator *regulator,
 	if (ret < 0)
 		goto out2;
 
-	if (rdev->supply && (rdev->desc->min_dropout_uV ||
-				!rdev->desc->ops->get_voltage)) {
+	if (rdev->supply &&
+	    regulator_ops_is_valid(rdev->supply->rdev,
+				   REGULATOR_CHANGE_VOLTAGE) &&
+	    (rdev->desc->min_dropout_uV || !rdev->desc->ops->get_voltage)) {
 		int current_supply_uV;
 		int selector;
 
Signature · 1 line
2.11.0
author maintainer
#5 lore raw

Applied "regulator: core: Only propagate voltage changes to if it can change voltages" to the regulator tree

In reply to Mark Brown

The patch

regulator: core: Only propagate voltage changes to if it can change voltages

has been applied to the regulator tree at

git://git.kernel.org/pub/scm/linux/kernel/git/broonie/regulator.git

All being well this means that it will be integrated into the linux-next tree (usually sometime in the next 24 hours) and sent to Linus during the next merge window (or sooner if it is a bug fix), however if problems are discovered then the patch may be dropped or reverted.

You may get further e-mails resulting from automated or manual testing and review of the tree, please engage with people reporting problems and send followup patches addressing any issues that are reported if needed.

If any updates are required or you are submitting further changes they should be sent as incremental updates against current git, existing patches will not be replaced.

Please add any relevant lists and maintainers to the CCs when replying to this mail.

Thanks,
Mark

Quoted 1 line

From 43fc99f293cc802866bea904ca2f1f8573f236f7 Mon Sep 17 00:00:00 2001

From: Mark Brown <[email protected]>
Date: Thu, 13 Apr 2017 18:36:59 +0100
Subject: [PATCH] regulator: core: Only propagate voltage changes to if it can
change voltages

When we are propagating voltage changes to parent regulators don't bother if the parent does not have permission to change voltages. This simplifies error checking in the function for cases where the regulator lacks some of the voltage operations.

---
 drivers/regulator/core.c | 6 ++++--
 1 file changed, 4 insertions(+), 2 deletions(-)
drivers/regulator/core.c +4 -2
index aff302dfab5d..3f424ec4fc56 100644
@@ -2939,8 +2939,10 @@ static int regulator_set_voltage_unlocked(struct regulator *regulator,
 	if (ret < 0)
 		goto out2;
 
-	if (rdev->supply && (rdev->desc->min_dropout_uV ||
-				!rdev->desc->ops->get_voltage)) {
+	if (rdev->supply &&
+	    regulator_ops_is_valid(rdev->supply->rdev,
+				   REGULATOR_CHANGE_VOLTAGE) &&
+	    (rdev->desc->min_dropout_uV || !rdev->desc->ops->get_voltage)) {
 		int current_supply_uV;
 		int selector;
 
Signature · 1 line