rombios/ata: Wait for BSY to clear after write

PATCH In review Ross Lagerwall 3 participants 3 messages Jun 13, 2017

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 rombios/ata: Wait for BSY to clear after write

After rombios transfers the data for a write, it checks the status and fails if BSY is set. qemu-trad doesn't set BSY for PIO writes, but QEMU upstream does, and this causes rombios to fail writes because they are marked as BSY. Instead, wait for BSY to clear after a write.

INT 13 writes are probably rarely used these days, but they are used by GRUB 2 to write to its environment file which happens by default on Ubuntu.

---
 tools/firmware/rombios/rombios.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
tools/firmware/rombios/rombios.c +1 -1
index 58ace9b..51558ee 100644
@@ -3226,7 +3226,7 @@ ASM_END
     current++;
     write_word(ebda_seg, &EbdaData->ata.trsfsectors,current);
     count--;
-    status = inb(iobase1 + ATA_CB_STAT);
+    status = await_ide(NOT_BSY, iobase1, IDE_TIMEOUT);
     if (count == 0) {
       if ( (status & (ATA_CB_STAT_BSY | ATA_CB_STAT_RDY | ATA_CB_STAT_DF | ATA_CB_STAT_DRQ | ATA_CB_STAT_ERR) )
           != ATA_CB_STAT_RDY ) {
Signature · 7 lines
2.9.4


_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel
Acked-by on v1 1/1
#1 lore raw
Quoted 10 lines · Ross Lagerwall

After rombios transfers the data for a write, it checks the status and fails if BSY is set. qemu-trad doesn't set BSY for PIO writes, but QEMU upstream does, and this causes rombios to fail writes because they are marked as BSY. Instead, wait for BSY to clear after a write.

INT 13 writes are probably rarely used these days, but they are used by GRUB 2 to write to its environment file which happens by default on Ubuntu.

Ian/Wei: RomBIOS should probably join hvmloader under x86 maintainership, if you don't object?

Quoted 9 lines
---
 tools/firmware/rombios/rombios.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
tools/firmware/rombios/rombios.c +0 -0
index 58ace9b..51558ee 100644

tools/firmware/rombios/rombios.c ASM_END · line 3232

Quoted 8 lines
tools/firmware/rombios/rombios.c +1 -1
@@ -3226,7 +3226,7 @@ ASM_END
     current++;
     write_word(ebda_seg, &EbdaData->ata.trsfsectors,current);
     count--;
-    status = inb(iobase1 + ATA_CB_STAT);
+    status = await_ide(NOT_BSY, iobase1, IDE_TIMEOUT);
     if (count == 0) {
       if ( (status & (ATA_CB_STAT_BSY | ATA_CB_STAT_RDY | ATA_CB_STAT_DF | ATA_CB_STAT_DRQ | ATA_CB_STAT_ERR) )
           != ATA_CB_STAT_RDY ) {

_______________________________________________
Xen-devel mailing list
[email protected]
https://lists.xen.org/xen-devel

#2 lore raw
Quoted 10 lines · Andrew Cooper
Quoted 9 lines · Ross Lagerwall

After rombios transfers the data for a write, it checks the status and fails if BSY is set. qemu-trad doesn't set BSY for PIO writes, but QEMU upstream does, and this causes rombios to fail writes because they are marked as BSY. Instead, wait for BSY to clear after a write.

INT 13 writes are probably rarely used these days, but they are used by GRUB 2 to write to its environment file which happens by default on Ubuntu.

Quoted 7 lines
Quoted 1 line

Ian/Wei: RomBIOS should probably join hvmloader under x86 maintainership, if you don't object?

No I don't.

_______________________________________________
Xen-devel mailing list
[email protected]