New Driver for electrical energy measurement

DISCUSSION Greg KH 5 participants 8 messages Jul 12, 2017 – Jul 14, 2017 1 message not in the archive IIO

lore
Share & tools
lore

A message that is not in the archive (sent off-list or not yet received): 20170712141854.018293e7@xps13

Greg KH

author
#1 lore raw
Quoted 9 lines · Christian Gromm

Hi,

Microchip is planning to introduce a driver for a new companion chip series capable of electical energy measurement. However, we are not sure which location in the source tree is the most suitable. First thought was to put it into /drivers/powercap. But now we are in discussions whether it would make even more sense to introduce a new driver for electrical energy measuring or monitoring.

Why not just have it be an IIO device, I think they have energy sensors already (adding the iio mailing list to find out...)

Quoted 119 lines

Following is a rough overview of the part we want the driver for. Any input on this will be appreciated.

thanks,
Chris

=== Introduction

Following the recent focus on low-power systems, Microchip has designed a companion chip series capable of measuring the electrical energy flow of an electrical system. The series in question, EM Chip is capable of measuring the energy flow (in or out) of an electrical system by monitoring one or more power rails. The 1st chip of the series, EM Chip is able to measure the net energy flow over 4 different power rails. The chip itself is a small QFN16 (4mm x 4mm x 0.5mm) or WLCSP16 (2.25mm x 2.2mm) package.

=== Theory of Operation

In order to measure the amount of energy entering/exiting a system, a small shunt resistor is interleaved on a power rail. By measuring the small voltage drop across the shunt resistor (a known value), the electrical current is measured.

	I = U/R

Depending on whether the system is consuming or producing energy, the measured current value can be either a positive or negative number.

To get the instantaneous power figure we will have to measure the power rail’s voltage and multiply it with the measured value for the current

P = V * I = V * U_shunt/R

Knowing the instantaneous power and by making a high enough sample rate (for measuring the current and the power rail voltage), we can assume the measured value for power is equal to the average power figure for the amount of time between 2 sampling moments.

Now that we also know the average power for a given time interval (dt_x = time between 2 sampling moments; sampling speed is known), we can measure the energy amount entering or exiting the system between 2 sampling moments

E_partial_x = P * dt_x

Having the energy information available, we can continue to add the subsequent energy values for as long as the system is active. The amount of energy is the sum of all the partial energy values measured for each time interval E = Sum (E_partial_x), where x can take values from 0 till infinite.

=== Chip Operation

The EM Chip chip uses the same principles of operation as presented in the “Theory of Operation” and it does so for a number of 4 channels. 4 independent power rails can be energy monitored in the same time. The chip is controlled over I2C/SMBus by an I2C/SMBus master.

In order to reduce the amount of information traffic between the EM Chip and the entity asking for its information, the chip features large accumulator energy registers for the accumulated energy values. It can accumulate up to 2^24 power values. Depending on the selected chip’s sampling speed, such a number of samples are produced in about 4.5 hours (fastest sampling speed) up to 582.5 hours or more than 24 days (lowest sampling speed).

EM Chip measures the power as a 28-bits number. The 28-bits number is the multiplication result of the 16-bits number used to measure the power rail voltage and the 12-bits number used for measuring the voltage drop across the power rail shunt resistor.

If bidirectional energy flow is required, the power is measured as a 27-bits number and 1 bit for the sign. When no bidirectional flow is needed, the power value is measured as an unsigned 28-bits number.

Due to the relatively large size of the accumulated energy registers inside the chip (48 bits), in the worst case scenario (power values are full scale numbers), a number of 2^20 full-scale power values can be measured before energy register’s overflow. Using the fastest sampling speed, the accumulated energy registers overflows only after a bit over 17 minutes, while at the lowest sampling speed, it would overflow in over 36 hours.

Thus, the chip requires infrequent reads of the accumulated energy registers. Even in the worst case scenario, the time between 2 consecutive energy accumulator reads can be over 17 minutes !

In order to keep a longer history of energy measurements, an I2C/SMBus master (e.g. SoC) would read the accumulated energy register values and then use larger “soft” accumulated energy registers to extend the maximum overflow period.

The EM Chip chip can monitor rails up to 32V. It can monitor the energy amounts used by various sub-components of a system (e.g. CPU, GPU, memory, hard-drives, USB ports, backlight, wireless adapters, cameras, displays, …)

EM Chip is able to start operating immediately after power-up with no CPU intervention at all. Such a feature is useful, because it can show the amount of energy consumed by a system before the latter finished booting its operating system.

The chip’s own current draw is around 20uA (in low-power mode, lowest sampling speed - 8 samples/sec) to 675uA (for the highest sampling speed - 1024 samples/sec)

When operated in low-power mode, it can be used to monitor the stand-by energy draw of the system. As an example, such a mode is useful when a system is suspended to RAM or to measure the energy usage from the power on till the booting process is finished.

=== Linux Driver

While the chip is due to be publicly released in Q3 2017, a selected number of PC OEM manufacturers will include one or more EM Chip chips on their systems. We would like to include a driver for EM Chip chip and its follow-up products, such that Linux Kernel will be able to provide the energy information as soon as computing systems using this series of chips will become available.

Quoted 2 lines

By providing accurate energy measurements, the computing systems along with their operating systems will be able to run more efficiently.

Do you have any kernel code already to show how this will get hooked up to the device? Do you need device tree bindings for the sensors, or are they on a discoverable bus?

thanks,

greg k-h

#2 lore raw
Quoted 12 lines · On Wed, 12 Jul 2017 14:51:01 +0200 Greg KH <[email protected]> wrote:
Quoted 10 lines · Christian Gromm

Hi,

Microchip is planning to introduce a driver for a new companion chip series capable of electical energy measurement. However, we are not sure which location in the source tree is the most suitable. First thought was to put it into /drivers/powercap. But now we are in discussions whether it would make even more sense to introduce a new driver for electrical energy measuring or monitoring.

Quoted 2 lines

Why not just have it be an IIO device, I think they have energy sensors already (adding the iio mailing list to find out...)

We thought about hwmon, but not IIO.

Quoted 127 lines
Quoted 127 lines

Following is a rough overview of the part we want the driver for. Any input on this will be appreciated.

thanks,
Chris

=== Introduction

Following the recent focus on low-power systems, Microchip has designed a companion chip series capable of measuring the electrical energy flow of an electrical system. The series in question, EM Chip is capable of measuring the energy flow (in or out) of an electrical system by monitoring one or more power rails. The 1st chip of the series, EM Chip is able to measure the net energy flow over 4 different power rails. The chip itself is a small QFN16 (4mm x 4mm x 0.5mm) or WLCSP16 (2.25mm x 2.2mm) package.

=== Theory of Operation

In order to measure the amount of energy entering/exiting a system, a small shunt resistor is interleaved on a power rail. By measuring the small voltage drop across the shunt resistor (a known value), the electrical current is measured.

	I = U/R

Depending on whether the system is consuming or producing energy, the measured current value can be either a positive or negative number.

To get the instantaneous power figure we will have to measure the power rail’s voltage and multiply it with the measured value for the current

P = V * I = V * U_shunt/R

Knowing the instantaneous power and by making a high enough sample rate (for measuring the current and the power rail voltage), we can assume the measured value for power is equal to the average power figure for the amount of time between 2 sampling moments.

Now that we also know the average power for a given time interval (dt_x = time between 2 sampling moments; sampling speed is known), we can measure the energy amount entering or exiting the system between 2 sampling moments

E_partial_x = P * dt_x

Having the energy information available, we can continue to add the subsequent energy values for as long as the system is active. The amount of energy is the sum of all the partial energy values measured for each time interval E = Sum (E_partial_x), where x can take values from 0 till infinite.

=== Chip Operation

The EM Chip chip uses the same principles of operation as presented in the “Theory of Operation” and it does so for a number of 4 channels. 4 independent power rails can be energy monitored in the same time. The chip is controlled over I2C/SMBus by an I2C/SMBus master.

In order to reduce the amount of information traffic between the EM Chip and the entity asking for its information, the chip features large accumulator energy registers for the accumulated energy values. It can accumulate up to 2^24 power values. Depending on the selected chip’s sampling speed, such a number of samples are produced in about 4.5 hours (fastest sampling speed) up to 582.5 hours or more than 24 days (lowest sampling speed).

EM Chip measures the power as a 28-bits number. The 28-bits number is the multiplication result of the 16-bits number used to measure the power rail voltage and the 12-bits number used for measuring the voltage drop across the power rail shunt resistor.

If bidirectional energy flow is required, the power is measured as a 27-bits number and 1 bit for the sign. When no bidirectional flow is needed, the power value is measured as an unsigned 28-bits number.

Due to the relatively large size of the accumulated energy registers inside the chip (48 bits), in the worst case scenario (power values are full scale numbers), a number of 2^20 full-scale power values can be measured before energy register’s overflow. Using the fastest sampling speed, the accumulated energy registers overflows only after a bit over 17 minutes, while at the lowest sampling speed, it would overflow in over 36 hours.

Thus, the chip requires infrequent reads of the accumulated energy registers. Even in the worst case scenario, the time between 2 consecutive energy accumulator reads can be over 17 minutes !

In order to keep a longer history of energy measurements, an I2C/SMBus master (e.g. SoC) would read the accumulated energy register values and then use larger “soft” accumulated energy registers to extend the maximum overflow period.

The EM Chip chip can monitor rails up to 32V. It can monitor the energy amounts used by various sub-components of a system (e.g. CPU, GPU, memory, hard-drives, USB ports, backlight, wireless adapters, cameras, displays, …)

EM Chip is able to start operating immediately after power-up with no CPU intervention at all. Such a feature is useful, because it can show the amount of energy consumed by a system before the latter finished booting its operating system.

The chip’s own current draw is around 20uA (in low-power mode, lowest sampling speed - 8 samples/sec) to 675uA (for the highest sampling speed - 1024 samples/sec)

When operated in low-power mode, it can be used to monitor the stand-by energy draw of the system. As an example, such a mode is useful when a system is suspended to RAM or to measure the energy usage from the power on till the booting process is finished.

=== Linux Driver

While the chip is due to be publicly released in Q3 2017, a selected number of PC OEM manufacturers will include one or more EM Chip chips on their systems. We would like to include a driver for EM Chip chip and its follow-up products, such that Linux Kernel will be able to provide the energy information as soon as computing systems using this series of chips will become available.

Quoted 8 lines
Quoted 3 lines

By providing accurate energy measurements, the computing systems along with their operating systems will be able to run more efficiently.

Do you have any kernel code already to show how this will get hooked up to the device? Do you need device tree bindings for the sensors, or are they on a discoverable bus?

No, I don't. I wanted to bring this up on the mailing list first, before I get started.
Sensors are attached via I2C.

thanks,
Chris

-

#3 lore raw
Quoted 152 lines · On Wed, 12 Jul 2017 15:19:40 +0200 Christian Gromm…
Quoted 12 lines · On Wed, 12 Jul 2017 14:51:01 +0200 Greg KH <[email protected]> wrote:
Quoted 10 lines · Christian Gromm

Hi,

Microchip is planning to introduce a driver for a new companion chip series capable of electical energy measurement. However, we are not sure which location in the source tree is the most suitable. First thought was to put it into /drivers/powercap. But now we are in discussions whether it would make even more sense to introduce a new driver for electrical energy measuring or monitoring.

Quoted 2 lines

Why not just have it be an IIO device, I think they have energy sensors already (adding the iio mailing list to find out...)

We thought about hwmon, but not IIO.

Quoted 132 lines
Quoted 130 lines

Following is a rough overview of the part we want the driver for. Any input on this will be appreciated.

thanks,
Chris

=== Introduction

Following the recent focus on low-power systems, Microchip has designed a companion chip series capable of measuring the electrical energy flow of an electrical system. The series in question, EM Chip is capable of measuring the energy flow (in or out) of an electrical system by monitoring one or more power rails. The 1st chip of the series, EM Chip is able to measure the net energy flow over 4 different power rails. The chip itself is a small QFN16 (4mm x 4mm x 0.5mm) or WLCSP16 (2.25mm x 2.2mm) package.

=== Theory of Operation

In order to measure the amount of energy entering/exiting a system, a small shunt resistor is interleaved on a power rail. By measuring the small voltage drop across the shunt resistor (a known value), the electrical current is measured.

	I = U/R

Depending on whether the system is consuming or producing energy, the measured current value can be either a positive or negative number.

To get the instantaneous power figure we will have to measure the power rail’s voltage and multiply it with the measured value for the current

P = V * I = V * U_shunt/R

Knowing the instantaneous power and by making a high enough sample rate (for measuring the current and the power rail voltage), we can assume the measured value for power is equal to the average power figure for the amount of time between 2 sampling moments.

Now that we also know the average power for a given time interval (dt_x = time between 2 sampling moments; sampling speed is known), we can measure the energy amount entering or exiting the system between 2 sampling moments

E_partial_x = P * dt_x

Having the energy information available, we can continue to add the subsequent energy values for as long as the system is active. The amount of energy is the sum of all the partial energy values measured for each time interval E = Sum (E_partial_x), where x can take values from 0 till infinite.

=== Chip Operation

The EM Chip chip uses the same principles of operation as presented in the “Theory of Operation” and it does so for a number of 4 channels. 4 independent power rails can be energy monitored in the same time. The chip is controlled over I2C/SMBus by an I2C/SMBus master.

In order to reduce the amount of information traffic between the EM Chip and the entity asking for its information, the chip features large accumulator energy registers for the accumulated energy values. It can accumulate up to 2^24 power values. Depending on the selected chip’s sampling speed, such a number of samples are produced in about 4.5 hours (fastest sampling speed) up to 582.5 hours or more than 24 days (lowest sampling speed).

EM Chip measures the power as a 28-bits number. The 28-bits number is the multiplication result of the 16-bits number used to measure the power rail voltage and the 12-bits number used for measuring the voltage drop across the power rail shunt resistor.

If bidirectional energy flow is required, the power is measured as a 27-bits number and 1 bit for the sign. When no bidirectional flow is needed, the power value is measured as an unsigned 28-bits number.

Due to the relatively large size of the accumulated energy registers inside the chip (48 bits), in the worst case scenario (power values are full scale numbers), a number of 2^20 full-scale power values can be measured before energy register’s overflow. Using the fastest sampling speed, the accumulated energy registers overflows only after a bit over 17 minutes, while at the lowest sampling speed, it would overflow in over 36 hours.

Thus, the chip requires infrequent reads of the accumulated energy registers. Even in the worst case scenario, the time between 2 consecutive energy accumulator reads can be over 17 minutes !

In order to keep a longer history of energy measurements, an I2C/SMBus master (e.g. SoC) would read the accumulated energy register values and then use larger “soft” accumulated energy registers to extend the maximum overflow period.

The EM Chip chip can monitor rails up to 32V. It can monitor the energy amounts used by various sub-components of a system (e.g. CPU, GPU, memory, hard-drives, USB ports, backlight, wireless adapters, cameras, displays, …)

EM Chip is able to start operating immediately after power-up with no CPU intervention at all. Such a feature is useful, because it can show the amount of energy consumed by a system before the latter finished booting its operating system.

The chip’s own current draw is around 20uA (in low-power mode, lowest sampling speed - 8 samples/sec) to 675uA (for the highest sampling speed - 1024 samples/sec)

When operated in low-power mode, it can be used to monitor the stand-by energy draw of the system. As an example, such a mode is useful when a system is suspended to RAM or to measure the energy usage from the power on till the booting process is finished.

=== Linux Driver

While the chip is due to be publicly released in Q3 2017, a selected number of PC OEM manufacturers will include one or more EM Chip chips on their systems. We would like to include a driver for EM Chip chip and its follow-up products, such that Linux Kernel will be able to provide the energy information as soon as computing systems using this series of chips will become available.

By providing accurate energy measurements, the computing systems along with their operating systems will be able to run more efficiently.

Quoted 7 lines
Quoted 3 lines

Do you have any kernel code already to show how this will get hooked up to the device? Do you need device tree bindings for the sensors, or are they on a discoverable bus?

No, I don't. I wanted to bring this up on the mailing list first, before I get started.
Sensors are attached via I2C.

Sure, I don't blame you having myself gone through several subsystems with a driver in the past!

As Greg mentioned there are existing IIO drivers doing similar power measurements. So yes, a driver for such a part would be welcome.

I can see we may be 'straining' some of the interfaces a bit for those 48 bit values, but we can probably do something simple using the two 32 bit values available from a raw read in IIO.

Going to get awkward the first time we get a 65+ bit device though. There goes my assumptions again :(

Anyhow, nice sounding part so looking forward to seeing some code when you are ready.

Note we do have additional energy drivers still in staging (dating back to the early days of IIO) but those are 3 phase units so not so relevant (and their interfaces need some work which is why they are still in staging).

The adc/ina2xx_adc.c driver is probably a better place to start.

Hmm. The only thing that makes me doubt IIO as the obvious place is that the focus is clearly on PC energy monitoring. Now you can bridge IIO to hwmon but I'd like a bit of input from Guenter on whether that is a sensible approach here.

By the sound of it the device will have much wider uses, but the initial focus you state makes this slightly more interesting than if we were guessing what it was for ;)

Jonathan

Quoted 11 lines

thanks,
Chris

-
--
To unsubscribe from this list: send the line "unsubscribe linux-iio" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

#4 lore raw
Quoted 184 lines · Jonathan Cameron
Quoted 152 lines · On Wed, 12 Jul 2017 15:19:40 +0200 Christian Gromm…
Quoted 12 lines · On Wed, 12 Jul 2017 14:51:01 +0200 Greg KH <[email protected]> wrote:
Quoted 10 lines · Christian Gromm

Hi,

Microchip is planning to introduce a driver for a new companion chip series capable of electical energy measurement. However, we are not sure which location in the source tree is the most suitable. First thought was to put it into /drivers/powercap. But now we are in discussions whether it would make even more sense to introduce a new driver for electrical energy measuring or monitoring.

Quoted 2 lines

Why not just have it be an IIO device, I think they have energy sensors already (adding the iio mailing list to find out...)

We thought about hwmon, but not IIO.

Quoted 132 lines
Quoted 130 lines

Following is a rough overview of the part we want the driver for. Any input on this will be appreciated.

thanks,
Chris

=== Introduction

Following the recent focus on low-power systems, Microchip has designed a companion chip series capable of measuring the electrical energy flow of an electrical system. The series in question, EM Chip is capable of measuring the energy flow (in or out) of an electrical system by monitoring one or more power rails. The 1st chip of the series, EM Chip is able to measure the net energy flow over 4 different power rails. The chip itself is a small QFN16 (4mm x 4mm x 0.5mm) or WLCSP16 (2.25mm x 2.2mm) package.

=== Theory of Operation

In order to measure the amount of energy entering/exiting a system, a small shunt resistor is interleaved on a power rail. By measuring the small voltage drop across the shunt resistor (a known value), the electrical current is measured.

	I = U/R

Depending on whether the system is consuming or producing energy, the measured current value can be either a positive or negative number.

To get the instantaneous power figure we will have to measure the power rail’s voltage and multiply it with the measured value for the current

P = V * I = V * U_shunt/R

Knowing the instantaneous power and by making a high enough sample rate (for measuring the current and the power rail voltage), we can assume the measured value for power is equal to the average power figure for the amount of time between 2 sampling moments.

Now that we also know the average power for a given time interval (dt_x = time between 2 sampling moments; sampling speed is known), we can measure the energy amount entering or exiting the system between 2 sampling moments

E_partial_x = P * dt_x

Having the energy information available, we can continue to add the subsequent energy values for as long as the system is active. The amount of energy is the sum of all the partial energy values measured for each time interval E = Sum (E_partial_x), where x can take values from 0 till infinite.

=== Chip Operation

The EM Chip chip uses the same principles of operation as presented in the “Theory of Operation” and it does so for a number of 4 channels. 4 independent power rails can be energy monitored in the same time. The chip is controlled over I2C/SMBus by an I2C/SMBus master.

In order to reduce the amount of information traffic between the EM Chip and the entity asking for its information, the chip features large accumulator energy registers for the accumulated energy values. It can accumulate up to 2^24 power values. Depending on the selected chip’s sampling speed, such a number of samples are produced in about 4.5 hours (fastest sampling speed) up to 582.5 hours or more than 24 days (lowest sampling speed).

EM Chip measures the power as a 28-bits number. The 28-bits number is the multiplication result of the 16-bits number used to measure the power rail voltage and the 12-bits number used for measuring the voltage drop across the power rail shunt resistor.

If bidirectional energy flow is required, the power is measured as a 27-bits number and 1 bit for the sign. When no bidirectional flow is needed, the power value is measured as an unsigned 28-bits number.

Due to the relatively large size of the accumulated energy registers inside the chip (48 bits), in the worst case scenario (power values are full scale numbers), a number of 2^20 full-scale power values can be measured before energy register’s overflow. Using the fastest sampling speed, the accumulated energy registers overflows only after a bit over 17 minutes, while at the lowest sampling speed, it would overflow in over 36 hours.

Thus, the chip requires infrequent reads of the accumulated energy registers. Even in the worst case scenario, the time between 2 consecutive energy accumulator reads can be over 17 minutes !

In order to keep a longer history of energy measurements, an I2C/SMBus master (e.g. SoC) would read the accumulated energy register values and then use larger “soft” accumulated energy registers to extend the maximum overflow period.

The EM Chip chip can monitor rails up to 32V. It can monitor the energy amounts used by various sub-components of a system (e.g. CPU, GPU, memory, hard-drives, USB ports, backlight, wireless adapters, cameras, displays, …)

EM Chip is able to start operating immediately after power-up with no CPU intervention at all. Such a feature is useful, because it can show the amount of energy consumed by a system before the latter finished booting its operating system.

The chip’s own current draw is around 20uA (in low-power mode, lowest sampling speed - 8 samples/sec) to 675uA (for the highest sampling speed - 1024 samples/sec)

When operated in low-power mode, it can be used to monitor the stand-by energy draw of the system. As an example, such a mode is useful when a system is suspended to RAM or to measure the energy usage from the power on till the booting process is finished.

=== Linux Driver

While the chip is due to be publicly released in Q3 2017, a selected number of PC OEM manufacturers will include one or more EM Chip chips on their systems. We would like to include a driver for EM Chip chip and its follow-up products, such that Linux Kernel will be able to provide the energy information as soon as computing systems using this series of chips will become available.

By providing accurate energy measurements, the computing systems along with their operating systems will be able to run more efficiently.

Quoted 7 lines
Quoted 3 lines

Do you have any kernel code already to show how this will get hooked up to the device? Do you need device tree bindings for the sensors, or are they on a discoverable bus?

No, I don't. I wanted to bring this up on the mailing list first, before I get started.
Sensors are attached via I2C.

Sure, I don't blame you having myself gone through several subsystems with a driver in the past!

As Greg mentioned there are existing IIO drivers doing similar power measurements. So yes, a driver for such a part would be welcome.

I can see we may be 'straining' some of the interfaces a bit for those 48 bit values, but we can probably do something simple using the two 32 bit values available from a raw read in IIO.

Going to get awkward the first time we get a 65+ bit device though. There goes my assumptions again :(

Anyhow, nice sounding part so looking forward to seeing some code when you are ready.

Note we do have additional energy drivers still in staging (dating back to the early days of IIO) but those are 3 phase units so not so relevant (and their interfaces need some work which is why they are still in staging).

Quoted 7 lines

The adc/ina2xx_adc.c driver is probably a better place to start.

Hmm. The only thing that makes me doubt IIO as the obvious place is that the focus is clearly on PC energy monitoring. Now you can bridge IIO to hwmon but I'd like a bit of input from Guenter on whether that is a sensible approach here.

I don't think I have enough information for a sensible answer. What else besides raw energy measurement do the chips support ? Do they have limits / alarms ? Do they measure voltage and current as well ? If not, iio would be the better place. If the chips support PMBus (which would make sense, but it doesn't sound like it), hwmon would obviously be better, since it already has the necessary infrastructure.

Guenter

Quoted 19 lines

By the sound of it the device will have much wider uses, but the initial focus you state makes this slightly more interesting than if we were guessing what it was for ;)

Jonathan

Quoted 11 lines

thanks,
Chris

-
--
To unsubscribe from this list: send the line "unsubscribe linux-iio" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

#5 lore raw
Quoted 193 lines · Guenter Roeck
Quoted 184 lines · Jonathan Cameron
Quoted 152 lines · On Wed, 12 Jul 2017 15:19:40 +0200 Christian Gromm…
Quoted 12 lines · On Wed, 12 Jul 2017 14:51:01 +0200 Greg KH <[email protected]> wrote:
Quoted 10 lines · Christian Gromm

Hi,

Microchip is planning to introduce a driver for a new companion chip series capable of electical energy measurement. However, we are not sure which location in the source tree is the most suitable. First thought was to put it into /drivers/powercap. But now we are in discussions whether it would make even more sense to introduce a new driver for electrical energy measuring or monitoring.

Quoted 2 lines

Why not just have it be an IIO device, I think they have energy sensors already (adding the iio mailing list to find out...)

We thought about hwmon, but not IIO.

Quoted 132 lines
Quoted 130 lines

Following is a rough overview of the part we want the driver for. Any input on this will be appreciated.

thanks,
Chris

=== Introduction

Following the recent focus on low-power systems, Microchip has designed a companion chip series capable of measuring the electrical energy flow of an electrical system. The series in question, EM Chip is capable of measuring the energy flow (in or out) of an electrical system by monitoring one or more power rails. The 1st chip of the series, EM Chip is able to measure the net energy flow over 4 different power rails. The chip itself is a small QFN16 (4mm x 4mm x 0.5mm) or WLCSP16 (2.25mm x 2.2mm) package.

=== Theory of Operation

In order to measure the amount of energy entering/exiting a system, a small shunt resistor is interleaved on a power rail. By measuring the small voltage drop across the shunt resistor (a known value), the electrical current is measured.

    I = U/R

Depending on whether the system is consuming or producing energy, the measured current value can be either a positive or negative number.

To get the instantaneous power figure we will have to measure the power rail’s voltage and multiply it with the measured value for the current

P = V * I = V * U_shunt/R

Knowing the instantaneous power and by making a high enough sample rate (for measuring the current and the power rail voltage), we can assume the measured value for power is equal to the average power figure for the amount of time between 2 sampling moments.

Now that we also know the average power for a given time interval (dt_x = time between 2 sampling moments; sampling speed is known), we can measure the energy amount entering or exiting the system between 2 sampling moments

E_partial_x = P * dt_x

Having the energy information available, we can continue to add the subsequent energy values for as long as the system is active. The amount of energy is the sum of all the partial energy values measured for each time interval E = Sum (E_partial_x), where x can take values from 0 till infinite.

=== Chip Operation

The EM Chip chip uses the same principles of operation as presented in the “Theory of Operation” and it does so for a number of 4 channels. 4 independent power rails can be energy monitored in the same time. The chip is controlled over I2C/SMBus by an I2C/SMBus master.

In order to reduce the amount of information traffic between the EM Chip and the entity asking for its information, the chip features large accumulator energy registers for the accumulated energy values. It can accumulate up to 2^24 power values. Depending on the selected chip’s sampling speed, such a number of samples are produced in about 4.5 hours (fastest sampling speed) up to 582.5 hours or more than 24 days (lowest sampling speed).

EM Chip measures the power as a 28-bits number. The 28-bits number is the multiplication result of the 16-bits number used to measure the power rail voltage and the 12-bits number used for measuring the voltage drop across the power rail shunt resistor.

If bidirectional energy flow is required, the power is measured as a 27-bits number and 1 bit for the sign. When no bidirectional flow is needed, the power value is measured as an unsigned 28-bits number.

Due to the relatively large size of the accumulated energy registers inside the chip (48 bits), in the worst case scenario (power values are full scale numbers), a number of 2^20 full-scale power values can be measured before energy register’s overflow. Using the fastest sampling speed, the accumulated energy registers overflows only after a bit over 17 minutes, while at the lowest sampling speed, it would overflow in over 36 hours.

Thus, the chip requires infrequent reads of the accumulated energy registers. Even in the worst case scenario, the time between 2 consecutive energy accumulator reads can be over 17 minutes !

In order to keep a longer history of energy measurements, an I2C/SMBus master (e.g. SoC) would read the accumulated energy register values and then use larger “soft” accumulated energy registers to extend the maximum overflow period.

The EM Chip chip can monitor rails up to 32V. It can monitor the energy amounts used by various sub-components of a system (e.g. CPU, GPU, memory, hard-drives, USB ports, backlight, wireless adapters, cameras, displays, …)

EM Chip is able to start operating immediately after power-up with no CPU intervention at all. Such a feature is useful, because it can show the amount of energy consumed by a system before the latter finished booting its operating system.

The chip’s own current draw is around 20uA (in low-power mode, lowest sampling speed - 8 samples/sec) to 675uA (for the highest sampling speed - 1024 samples/sec)

When operated in low-power mode, it can be used to monitor the stand-by energy draw of the system. As an example, such a mode is useful when a system is suspended to RAM or to measure the energy usage from the power on till the booting process is finished.

=== Linux Driver

While the chip is due to be publicly released in Q3 2017, a selected number of PC OEM manufacturers will include one or more EM Chip chips on their systems. We would like to include a driver for EM Chip chip and its follow-up products, such that Linux Kernel will be able to provide the energy information as soon as computing systems using this series of chips will become available.

By providing accurate energy measurements, the computing systems along with their operating systems will be able to run more efficiently.

Quoted 7 lines
Quoted 3 lines

Do you have any kernel code already to show how this will get hooked up to the device? Do you need device tree bindings for the sensors, or are they on a discoverable bus?

No, I don't. I wanted to bring this up on the mailing list first, before I get started.
Sensors are attached via I2C.

Sure, I don't blame you having myself gone through several subsystems with a driver in the past!

As Greg mentioned there are existing IIO drivers doing similar power measurements. So yes, a driver for such a part would be welcome.

I can see we may be 'straining' some of the interfaces a bit for those 48 bit values, but we can probably do something simple using the two 32 bit values available from a raw read in IIO.

Going to get awkward the first time we get a 65+ bit device though. There goes my assumptions again :(

Anyhow, nice sounding part so looking forward to seeing some code when you are ready.

Note we do have additional energy drivers still in staging (dating back to the early days of IIO) but those are 3 phase units so not so relevant (and their interfaces need some work which is why they are still in staging).

Quoted 7 lines

The adc/ina2xx_adc.c driver is probably a better place to start.

Hmm. The only thing that makes me doubt IIO as the obvious place is that the focus is clearly on PC energy monitoring. Now you can bridge IIO to hwmon but I'd like a bit of input from Guenter on whether that is a sensible approach here.

Quoted 6 lines

I don't think I have enough information for a sensible answer. What else besides raw energy measurement do the chips support ? Do they have limits / alarms ? Do they measure voltage and current as well ? If not, iio would be the better place. If the chips support PMBus (which would make sense, but it doesn't sound like it), hwmon would obviously be better, since it already has the necessary infrastructure.

There is also some precedence for these kinds of devices in the power-supply framework. E.g. the LTC2941 and similar work in a similar way to whats described above
(https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/tree/drivers/power/supply/ltc2941-battery-gauge.c
http://cds.linear.com/docs/en/datasheet/2941fb.pdf). Isn't it lovely to have so much choice?

#6 lore raw
Quoted 201 lines · Lars-Peter Clausen
Quoted 193 lines · Guenter Roeck
Quoted 184 lines · Jonathan Cameron
Quoted 152 lines · On Wed, 12 Jul 2017 15:19:40 +0200 Christian Gromm…
Quoted 12 lines · On Wed, 12 Jul 2017 14:51:01 +0200 Greg KH <[email protected]> wrote:
Quoted 10 lines · Christian Gromm

Hi,

Microchip is planning to introduce a driver for a new companion chip series capable of electical energy measurement. However, we are not sure which location in the source tree is the most suitable. First thought was to put it into /drivers/powercap. But now we are in discussions whether it would make even more sense to introduce a new driver for electrical energy measuring or monitoring.

Quoted 2 lines

Why not just have it be an IIO device, I think they have energy sensors already (adding the iio mailing list to find out...)

We thought about hwmon, but not IIO.

Quoted 132 lines
Quoted 130 lines

Following is a rough overview of the part we want the driver for. Any input on this will be appreciated.

thanks,
Chris

=== Introduction

Following the recent focus on low-power systems, Microchip has designed a companion chip series capable of measuring the electrical energy flow of an electrical system. The series in question, EM Chip is capable of measuring the energy flow (in or out) of an electrical system by monitoring one or more power rails. The 1st chip of the series, EM Chip is able to measure the net energy flow over 4 different power rails. The chip itself is a small QFN16 (4mm x 4mm x 0.5mm) or WLCSP16 (2.25mm x 2.2mm) package.

=== Theory of Operation

In order to measure the amount of energy entering/exiting a system, a small shunt resistor is interleaved on a power rail. By measuring the small voltage drop across the shunt resistor (a known value), the electrical current is measured.

     I = U/R

Depending on whether the system is consuming or producing energy, the measured current value can be either a positive or negative number.

To get the instantaneous power figure we will have to measure the power rail’s voltage and multiply it with the measured value for the current

P = V * I = V * U_shunt/R

Knowing the instantaneous power and by making a high enough sample rate (for measuring the current and the power rail voltage), we can assume the measured value for power is equal to the average power figure for the amount of time between 2 sampling moments.

Now that we also know the average power for a given time interval (dt_x = time between 2 sampling moments; sampling speed is known), we can measure the energy amount entering or exiting the system between 2 sampling moments

E_partial_x = P * dt_x

Having the energy information available, we can continue to add the subsequent energy values for as long as the system is active. The amount of energy is the sum of all the partial energy values measured for each time interval E = Sum (E_partial_x), where x can take values from 0 till infinite.

=== Chip Operation

The EM Chip chip uses the same principles of operation as presented in the “Theory of Operation” and it does so for a number of 4 channels. 4 independent power rails can be energy monitored in the same time. The chip is controlled over I2C/SMBus by an I2C/SMBus master.

In order to reduce the amount of information traffic between the EM Chip and the entity asking for its information, the chip features large accumulator energy registers for the accumulated energy values. It can accumulate up to 2^24 power values. Depending on the selected chip’s sampling speed, such a number of samples are produced in about 4.5 hours (fastest sampling speed) up to 582.5 hours or more than 24 days (lowest sampling speed).

EM Chip measures the power as a 28-bits number. The 28-bits number is the multiplication result of the 16-bits number used to measure the power rail voltage and the 12-bits number used for measuring the voltage drop across the power rail shunt resistor.

If bidirectional energy flow is required, the power is measured as a 27-bits number and 1 bit for the sign. When no bidirectional flow is needed, the power value is measured as an unsigned 28-bits number.

Due to the relatively large size of the accumulated energy registers inside the chip (48 bits), in the worst case scenario (power values are full scale numbers), a number of 2^20 full-scale power values can be measured before energy register’s overflow. Using the fastest sampling speed, the accumulated energy registers overflows only after a bit over 17 minutes, while at the lowest sampling speed, it would overflow in over 36 hours.

Thus, the chip requires infrequent reads of the accumulated energy registers. Even in the worst case scenario, the time between 2 consecutive energy accumulator reads can be over 17 minutes !

In order to keep a longer history of energy measurements, an I2C/SMBus master (e.g. SoC) would read the accumulated energy register values and then use larger “soft” accumulated energy registers to extend the maximum overflow period.

The EM Chip chip can monitor rails up to 32V. It can monitor the energy amounts used by various sub-components of a system (e.g. CPU, GPU, memory, hard-drives, USB ports, backlight, wireless adapters, cameras, displays, …)

EM Chip is able to start operating immediately after power-up with no CPU intervention at all. Such a feature is useful, because it can show the amount of energy consumed by a system before the latter finished booting its operating system.

The chip’s own current draw is around 20uA (in low-power mode, lowest sampling speed - 8 samples/sec) to 675uA (for the highest sampling speed - 1024 samples/sec)

When operated in low-power mode, it can be used to monitor the stand-by energy draw of the system. As an example, such a mode is useful when a system is suspended to RAM or to measure the energy usage from the power on till the booting process is finished.

=== Linux Driver

While the chip is due to be publicly released in Q3 2017, a selected number of PC OEM manufacturers will include one or more EM Chip chips on their systems. We would like to include a driver for EM Chip chip and its follow-up products, such that Linux Kernel will be able to provide the energy information as soon as computing systems using this series of chips will become available.

By providing accurate energy measurements, the computing systems along with their operating systems will be able to run more efficiently.

Quoted 7 lines
Quoted 3 lines

Do you have any kernel code already to show how this will get hooked up to the device? Do you need device tree bindings for the sensors, or are they on a discoverable bus?

No, I don't. I wanted to bring this up on the mailing list first, before I get started.
Sensors are attached via I2C.

Sure, I don't blame you having myself gone through several subsystems with a driver in the past!

As Greg mentioned there are existing IIO drivers doing similar power measurements. So yes, a driver for such a part would be welcome.

I can see we may be 'straining' some of the interfaces a bit for those 48 bit values, but we can probably do something simple using the two 32 bit values available from a raw read in IIO.

Going to get awkward the first time we get a 65+ bit device though. There goes my assumptions again :(

Anyhow, nice sounding part so looking forward to seeing some code when you are ready.

Note we do have additional energy drivers still in staging (dating back to the early days of IIO) but those are 3 phase units so not so relevant (and their interfaces need some work which is why they are still in staging).

Quoted 7 lines

The adc/ina2xx_adc.c driver is probably a better place to start.

Hmm. The only thing that makes me doubt IIO as the obvious place is that the focus is clearly on PC energy monitoring. Now you can bridge IIO to hwmon but I'd like a bit of input from Guenter on whether that is a sensible approach here.

Quoted 6 lines

I don't think I have enough information for a sensible answer. What else besides raw energy measurement do the chips support ? Do they have limits / alarms ? Do they measure voltage and current as well ? If not, iio would be the better place. If the chips support PMBus (which would make sense, but it doesn't sound like it), hwmon would obviously be better, since it already has the necessary infrastructure.

Quoted 7 lines

There is also some precedence for these kinds of devices in the power-supply framework. E.g. the LTC2941 and similar work in a similar way to whats described above
(https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/tree/drivers/power/supply/ltc2941-battery-gauge.c
http://cds.linear.com/docs/en/datasheet/2941fb.pdf). Isn't it lovely to have so much choice?

We already know from customers that USB-C net energy measurement (in and out) is also an aimed target of operation for the chip.

So, we really don't know where it fits best.
And yes it is lovely to have so much choice and he who has a choice, has the doldrums.

thanks,
Chris

#7 lore raw
Quoted 213 lines · On Fri, 14 Jul 2017 12:33:02 +0200 Christian Gromm…
Quoted 201 lines · Lars-Peter Clausen
Quoted 193 lines · Guenter Roeck
Quoted 184 lines · Jonathan Cameron
Quoted 152 lines · On Wed, 12 Jul 2017 15:19:40 +0200 Christian Gromm…
Quoted 12 lines · On Wed, 12 Jul 2017 14:51:01 +0200 Greg KH <[email protected]> wrote:
Quoted 10 lines · Christian Gromm

Hi,

Microchip is planning to introduce a driver for a new companion chip series capable of electical energy measurement. However, we are not sure which location in the source tree is the most suitable. First thought was to put it into /drivers/powercap. But now we are in discussions whether it would make even more sense to introduce a new driver for electrical energy measuring or monitoring.

Quoted 2 lines

Why not just have it be an IIO device, I think they have energy sensors already (adding the iio mailing list to find out...)

We thought about hwmon, but not IIO.

Quoted 132 lines
Quoted 130 lines

Following is a rough overview of the part we want the driver for. Any input on this will be appreciated.

thanks,
Chris

=== Introduction

Following the recent focus on low-power systems, Microchip has designed a companion chip series capable of measuring the electrical energy flow of an electrical system. The series in question, EM Chip is capable of measuring the energy flow (in or out) of an electrical system by monitoring one or more power rails. The 1st chip of the series, EM Chip is able to measure the net energy flow over 4 different power rails. The chip itself is a small QFN16 (4mm x 4mm x 0.5mm) or WLCSP16 (2.25mm x 2.2mm) package.

=== Theory of Operation

In order to measure the amount of energy entering/exiting a system, a small shunt resistor is interleaved on a power rail. By measuring the small voltage drop across the shunt resistor (a known value), the electrical current is measured.

     I = U/R

Depending on whether the system is consuming or producing energy, the measured current value can be either a positive or negative number.

To get the instantaneous power figure we will have to measure the power rail’s voltage and multiply it with the measured value for the current

P = V * I = V * U_shunt/R

Knowing the instantaneous power and by making a high enough sample rate (for measuring the current and the power rail voltage), we can assume the measured value for power is equal to the average power figure for the amount of time between 2 sampling moments.

Now that we also know the average power for a given time interval (dt_x = time between 2 sampling moments; sampling speed is known), we can measure the energy amount entering or exiting the system between 2 sampling moments

E_partial_x = P * dt_x

Having the energy information available, we can continue to add the subsequent energy values for as long as the system is active. The amount of energy is the sum of all the partial energy values measured for each time interval E = Sum (E_partial_x), where x can take values from 0 till infinite.

=== Chip Operation

The EM Chip chip uses the same principles of operation as presented in the “Theory of Operation” and it does so for a number of 4 channels. 4 independent power rails can be energy monitored in the same time. The chip is controlled over I2C/SMBus by an I2C/SMBus master.

In order to reduce the amount of information traffic between the EM Chip and the entity asking for its information, the chip features large accumulator energy registers for the accumulated energy values. It can accumulate up to 2^24 power values. Depending on the selected chip’s sampling speed, such a number of samples are produced in about 4.5 hours (fastest sampling speed) up to 582.5 hours or more than 24 days (lowest sampling speed).

EM Chip measures the power as a 28-bits number. The 28-bits number is the multiplication result of the 16-bits number used to measure the power rail voltage and the 12-bits number used for measuring the voltage drop across the power rail shunt resistor.

If bidirectional energy flow is required, the power is measured as a 27-bits number and 1 bit for the sign. When no bidirectional flow is needed, the power value is measured as an unsigned 28-bits number.

Due to the relatively large size of the accumulated energy registers inside the chip (48 bits), in the worst case scenario (power values are full scale numbers), a number of 2^20 full-scale power values can be measured before energy register’s overflow. Using the fastest sampling speed, the accumulated energy registers overflows only after a bit over 17 minutes, while at the lowest sampling speed, it would overflow in over 36 hours.

Thus, the chip requires infrequent reads of the accumulated energy registers. Even in the worst case scenario, the time between 2 consecutive energy accumulator reads can be over 17 minutes !

In order to keep a longer history of energy measurements, an I2C/SMBus master (e.g. SoC) would read the accumulated energy register values and then use larger “soft” accumulated energy registers to extend the maximum overflow period.

The EM Chip chip can monitor rails up to 32V. It can monitor the energy amounts used by various sub-components of a system (e.g. CPU, GPU, memory, hard-drives, USB ports, backlight, wireless adapters, cameras, displays, …)

EM Chip is able to start operating immediately after power-up with no CPU intervention at all. Such a feature is useful, because it can show the amount of energy consumed by a system before the latter finished booting its operating system.

The chip’s own current draw is around 20uA (in low-power mode, lowest sampling speed - 8 samples/sec) to 675uA (for the highest sampling speed - 1024 samples/sec)

When operated in low-power mode, it can be used to monitor the stand-by energy draw of the system. As an example, such a mode is useful when a system is suspended to RAM or to measure the energy usage from the power on till the booting process is finished.

=== Linux Driver

While the chip is due to be publicly released in Q3 2017, a selected number of PC OEM manufacturers will include one or more EM Chip chips on their systems. We would like to include a driver for EM Chip chip and its follow-up products, such that Linux Kernel will be able to provide the energy information as soon as computing systems using this series of chips will become available.

By providing accurate energy measurements, the computing systems along with their operating systems will be able to run more efficiently.

Quoted 7 lines
Quoted 3 lines

Do you have any kernel code already to show how this will get hooked up to the device? Do you need device tree bindings for the sensors, or are they on a discoverable bus?

No, I don't. I wanted to bring this up on the mailing list first, before I get started.
Sensors are attached via I2C.

Sure, I don't blame you having myself gone through several subsystems with a driver in the past!

As Greg mentioned there are existing IIO drivers doing similar power measurements. So yes, a driver for such a part would be welcome.

I can see we may be 'straining' some of the interfaces a bit for those 48 bit values, but we can probably do something simple using the two 32 bit values available from a raw read in IIO.

Going to get awkward the first time we get a 65+ bit device though. There goes my assumptions again :(

Anyhow, nice sounding part so looking forward to seeing some code when you are ready.

Note we do have additional energy drivers still in staging (dating back to the early days of IIO) but those are 3 phase units so not so relevant (and their interfaces need some work which is why they are still in staging).

Quoted 7 lines

The adc/ina2xx_adc.c driver is probably a better place to start.

Hmm. The only thing that makes me doubt IIO as the obvious place is that the focus is clearly on PC energy monitoring. Now you can bridge IIO to hwmon but I'd like a bit of input from Guenter on whether that is a sensible approach here.

Quoted 6 lines

I don't think I have enough information for a sensible answer. What else besides raw energy measurement do the chips support ? Do they have limits / alarms ? Do they measure voltage and current as well ? If not, iio would be the better place. If the chips support PMBus (which would make sense, but it doesn't sound like it), hwmon would obviously be better, since it already has the necessary infrastructure.

Quoted 7 lines

There is also some precedence for these kinds of devices in the power-supply framework. E.g. the LTC2941 and similar work in a similar way to whats described above
(https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/tree/drivers/power/supply/ltc2941-battery-gauge.c
http://cds.linear.com/docs/en/datasheet/2941fb.pdf). Isn't it lovely to have so much choice?

We already know from customers that USB-C net energy measurement (in and out) is also an aimed target of operation for the chip.

Quoted 6 lines

So, we really don't know where it fits best.
And yes it is lovely to have so much choice and he who has a choice, has the doldrums.

thanks,
Chris

My gut feeling is IIO and bridge to other subsystems as needed.

J

#8 lore raw
In reply to Guenter Roeck
Quoted 192 lines · Guenter Roeck
Quoted 183 lines · Jonathan Cameron
Quoted 151 lines · On Wed, 12 Jul 2017 15:19:40 +0200 Christian Gromm…
Quoted 12 lines · On Wed, 12 Jul 2017 14:51:01 +0200 Greg KH <[email protected]> wrote:
Quoted 10 lines · Christian Gromm

Hi,

Microchip is planning to introduce a driver for a new companion chip series capable of electical energy measurement. However, we are not sure which location in the source tree is the most suitable. First thought was to put it into /drivers/powercap. But now we are in discussions whether it would make even more sense to introduce a new driver for electrical energy measuring or monitoring.

Quoted 2 lines

Why not just have it be an IIO device, I think they have energy sensors already (adding the iio mailing list to find out...)

We thought about hwmon, but not IIO.

Quoted 131 lines
Quoted 129 lines

Following is a rough overview of the part we want the driver for. Any input on this will be appreciated.

thanks,
Chris

=== Introduction

Following the recent focus on low-power systems, Microchip has designed a companion chip series capable of measuring the electrical energy flow of an electrical system. The series in question, EM Chip is capable of measuring the energy flow (in or out) of an electrical system by monitoring one or more power rails. The 1st chip of the series, EM Chip is able to measure the net energy flow over 4 different power rails. The chip itself is a small QFN16 (4mm x 4mm x 0.5mm) or WLCSP16 (2.25mm x 2.2mm) package.

=== Theory of Operation

In order to measure the amount of energy entering/exiting a system, a small shunt resistor is interleaved on a power rail. By measuring the small voltage drop across the shunt resistor (a known value), the electrical current is measured.

    I = U/R

Depending on whether the system is consuming or producing energy, the measured current value can be either a positive or negative number.

To get the instantaneous power figure we will have to measure the power rail’s voltage and multiply it with the measured value for the current

P = V * I = V * U_shunt/R

Knowing the instantaneous power and by making a high enough sample rate (for measuring the current and the power rail voltage), we can assume the measured value for power is equal to the average power figure for the amount of time between 2 sampling moments.

Now that we also know the average power for a given time interval (dt_x = time between 2 sampling moments; sampling speed is known), we can measure the energy amount entering or exiting the system between 2 sampling moments

E_partial_x = P * dt_x

Having the energy information available, we can continue to add the subsequent energy values for as long as the system is active. The amount of energy is the sum of all the partial energy values measured for each time interval E = Sum (E_partial_x), where x can take values from 0 till infinite.

=== Chip Operation

The EM Chip chip uses the same principles of operation as presented in the “Theory of Operation” and it does so for a number of 4 channels. 4 independent power rails can be energy monitored in the same time. The chip is controlled over I2C/SMBus by an I2C/SMBus master.

In order to reduce the amount of information traffic between the EM Chip and the entity asking for its information, the chip features large accumulator energy registers for the accumulated energy values. It can accumulate up to 2^24 power values. Depending on the selected chip’s sampling speed, such a number of samples are produced in about 4.5 hours (fastest sampling speed) up to 582.5 hours or more than 24 days (lowest sampling speed).

EM Chip measures the power as a 28-bits number. The 28-bits number is the multiplication result of the 16-bits number used to measure the power rail voltage and the 12-bits number used for measuring the voltage drop across the power rail shunt resistor.

If bidirectional energy flow is required, the power is measured as a 27-bits number and 1 bit for the sign. When no bidirectional flow is needed, the power value is measured as an unsigned 28-bits number.

Due to the relatively large size of the accumulated energy registers inside the chip (48 bits), in the worst case scenario (power values are full scale numbers), a number of 2^20 full-scale power values can be measured before energy register’s overflow. Using the fastest sampling speed, the accumulated energy registers overflows only after a bit over 17 minutes, while at the lowest sampling speed, it would overflow in over 36 hours.

Thus, the chip requires infrequent reads of the accumulated energy registers. Even in the worst case scenario, the time between 2 consecutive energy accumulator reads can be over 17 minutes !

In order to keep a longer history of energy measurements, an I2C/SMBus master (e.g. SoC) would read the accumulated energy register values and then use larger “soft” accumulated energy registers to extend the maximum overflow period.

The EM Chip chip can monitor rails up to 32V. It can monitor the energy amounts used by various sub-components of a system (e.g. CPU, GPU, memory, hard-drives, USB ports, backlight, wireless adapters, cameras, displays, …)

EM Chip is able to start operating immediately after power-up with no CPU intervention at all. Such a feature is useful, because it can show the amount of energy consumed by a system before the latter finished booting its operating system.

The chip’s own current draw is around 20uA (in low-power mode, lowest sampling speed - 8 samples/sec) to 675uA (for the highest sampling speed - 1024 samples/sec)

When operated in low-power mode, it can be used to monitor the stand-by energy draw of the system. As an example, such a mode is useful when a system is suspended to RAM or to measure the energy usage from the power on till the booting process is finished.

=== Linux Driver

While the chip is due to be publicly released in Q3 2017, a selected number of PC OEM manufacturers will include one or more EM Chip chips on their systems. We would like to include a driver for EM Chip chip and its follow-up products, such that Linux Kernel will be able to provide the energy information as soon as computing systems using this series of chips will become available.

By providing accurate energy measurements, the computing systems along with their operating systems will be able to run more efficiently.

Quoted 7 lines
Quoted 3 lines

Do you have any kernel code already to show how this will get hooked up to the device? Do you need device tree bindings for the sensors, or are they on a discoverable bus?

No, I don't. I wanted to bring this up on the mailing list first, before I get started.
Sensors are attached via I2C.

Sure, I don't blame you having myself gone through several subsystems with a driver in the past!

As Greg mentioned there are existing IIO drivers doing similar power measurements. So yes, a driver for such a part would be welcome.

I can see we may be 'straining' some of the interfaces a bit for those 48 bit values, but we can probably do something simple using the two 32 bit values available from a raw read in IIO.

Going to get awkward the first time we get a 65+ bit device though. There goes my assumptions again :(

Anyhow, nice sounding part so looking forward to seeing some code when you are ready.

Note we do have additional energy drivers still in staging (dating back to the early days of IIO) but those are 3 phase units so not so relevant (and their interfaces need some work which is why they are still in staging).

Quoted 7 lines

The adc/ina2xx_adc.c driver is probably a better place to start.

Hmm. The only thing that makes me doubt IIO as the obvious place is that the focus is clearly on PC energy monitoring. Now you can bridge IIO to hwmon but I'd like a bit of input from Guenter on whether that is a sensible approach here.

Quoted 6 lines

I don't think I have enough information for a sensible answer. What else besides raw energy measurement do the chips support ? Do they have limits / alarms ? Do they measure voltage and current as well ? If not, iio would be the better place. If the chips support PMBus (which would make sense, but it doesn't sound like it), hwmon would obviously be better, since it already has the necessary infrastructure.

Besides the energy measurement for all four rails, the chip also measures the voltage, current and power. And there is one pin for alert events, which are configurable.

PMBus is not supported.

Another feature to be mentioned is the relatively long time between two subsequent CPU polls over I2C (due to the large accumulator registers of the chip).

thanks,
Chris