Skip to contentSkip to conversation

dt-bindings: iio: temperature: add MLX90632 device bindings

PATCH In review Crt Mori 2 participants 2 messages Jan 11, 2018 – Feb 4, 2018 1 message not in the archive

Subsystems (2)
lore
Share & tools
lore

Crt Mori

author
#0 lore raw

PATCH v13 2/3 dt-bindings: iio: temperature: add MLX90632 device bindings

Add device tree bindings for MLX90632 IR temperature sensor.

---
 .../bindings/iio/temperature/mlx90632.txt          | 28 ++++++++++++++++++++++
 1 file changed, 28 insertions(+)
 create mode 100644 Documentation/devicetree/bindings/iio/temperature/mlx90632.txt
Documentation/devicetree/bindings/iio/temperature/mlx90632.txt new file +28 -0
new file mode 100644
index 000000000000..0b05812001f8
@@ -0,0 +1,28 @@
+* Melexis MLX90632 contactless Infra Red temperature sensor
+
+Link to datasheet: https://www.melexis.com/en/documents/documentation/datasheets/datasheet-mlx90632
+
+There are various applications for the Infra Red contactless temperature sensor
+and MLX90632 is most suitable for consumer applications where measured object
+temperature is in range between -20 to 200 degrees Celsius with relative error
+of measurement below 1 degree Celsius in object temperature range for
+industrial applications. Since it can operate and measure ambient temperature
+in range of -20 to 85 degrees Celsius it is suitable also for outdoor use.
+
+Be aware that electronics surrounding the sensor can increase ambient
+temperature. MLX90632 can be calibrated to reduce the housing effect via
+already existing EEPROM parameters.
+
+Since measured object emissivity effects Infra Red energy emitted, emissivity
+should be set before requesting the object temperature.
+
+Required properties:
+  - compatible: should be "melexis,mlx90632"
+  - reg: the I2C address of the sensor (default 0x3a)
+
+Example:
+
+mlx90632@3a {
+	compatible = "melexis,mlx90632";
+	reg = <0x3a>;
+};
Signature · 1 line
2.15.0

A message that is not in the archive (sent off-list or not yet received): 20180111102010.27350-1-cmo-fc6wVz46lShBDgjK7y7TUQ@public.gmane.org

#2 lore raw
Quoted 4 lines · On Thu, 11 Jan 2018 11:20:10 +0100 Crt Mori…

Add device tree bindings for MLX90632 IR temperature sensor.

Applied to the togreg branch of iio.git and pushed out as testing for the autobuilders to play with it.

Jonathan

Quoted 39 lines
---
 .../bindings/iio/temperature/mlx90632.txt          | 28 ++++++++++++++++++++++
 1 file changed, 28 insertions(+)
 create mode 100644 Documentation/devicetree/bindings/iio/temperature/mlx90632.txt
Documentation/devicetree/bindings/iio/temperature/mlx90632.txt new file +28 -0
new file mode 100644
index 000000000000..0b05812001f8
@@ -0,0 +1,28 @@
+* Melexis MLX90632 contactless Infra Red temperature sensor
+
+Link to datasheet: https://www.melexis.com/en/documents/documentation/datasheets/datasheet-mlx90632
+
+There are various applications for the Infra Red contactless temperature sensor
+and MLX90632 is most suitable for consumer applications where measured object
+temperature is in range between -20 to 200 degrees Celsius with relative error
+of measurement below 1 degree Celsius in object temperature range for
+industrial applications. Since it can operate and measure ambient temperature
+in range of -20 to 85 degrees Celsius it is suitable also for outdoor use.
+
+Be aware that electronics surrounding the sensor can increase ambient
+temperature. MLX90632 can be calibrated to reduce the housing effect via
+already existing EEPROM parameters.
+
+Since measured object emissivity effects Infra Red energy emitted, emissivity
+should be set before requesting the object temperature.
+
+Required properties:
+  - compatible: should be "melexis,mlx90632"
+  - reg: the I2C address of the sensor (default 0x3a)
+
+Example:
+
+mlx90632@3a {
+	compatible = "melexis,mlx90632";
+	reg = <0x3a>;
+};