Skip to contentSkip to conversation

kselftests: timers: freq-step: Update maximum acceptable precision and errors

PATCH New Miroslav Lichvar 1 participant 1 message Apr 10, 2018

Subsystems (3)
lore
Share & tools
lore

Miroslav Lichvar

author reviewer
#0 lore raw

PATCH 1/1 kselftests: timers: freq-step: Update maximum acceptable precision and errors

PTI has a significant impact on precision of the MONOTONIC_RAW clock, which prevents a lot of computers from running the freq-step test. Increase the maximum acceptable precision for the test to not be skipped to 500 nanoseconds.

After commit 78b98e3c5a66 ("timekeeping/ntp: Determine the multiplier directly from NTP tick length") the frequency and time errors should be much smaller. Reduce the maximum acceptable values for the test to pass to 0.02 ppm and 50 nanoseconds respectively.

Cc John Stultz <[email protected]>
Cc Thomas Gleixner <[email protected]>
Cc Prarit Bhargava <[email protected]>
Cc Richard Cochran <[email protected]>
Cc Stephen Boyd <[email protected]>
---
 tools/testing/selftests/timers/freq-step.c | 6 +++---
 1 file changed, 3 insertions(+), 3 deletions(-)
tools/testing/selftests/timers/freq-step.c +3 -3
index 14a2b77fd012..cd094b49819f 100644
@@ -29,9 +29,9 @@
 #define SAMPLE_READINGS 10
 #define MEAN_SAMPLE_INTERVAL 0.1
 #define STEP_INTERVAL 1.0
-#define MAX_PRECISION 100e-9
-#define MAX_FREQ_ERROR 10e-6
-#define MAX_STDDEV 1000e-9
+#define MAX_PRECISION 500e-9
+#define MAX_FREQ_ERROR 0.02e-6
+#define MAX_STDDEV 50e-9
 
 #ifndef ADJ_SETOFFSET
   #define ADJ_SETOFFSET 0x0100
Signature · 1 line
2.14.3