fw_printenv: Don't bail out directly after one env read error

PATCH In review Ioan-Adrian Ratiu 4 participants 9 messages Jun 26, 2018 – Jul 2, 2018

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 fw_printenv: Don't bail out directly after one env read error

From: Joe Hershberger <[email protected]>

When using a redundant environment a read error should simply mean to not use that copy instead of giving up completely. The other copy may be just fine.

---
 tools/env/fw_env.c | 24 +++++++++++++++---------
 1 file changed, 15 insertions(+), 9 deletions(-)
tools/env/fw_env.c +15 -9
index a5d75958e1..3a5ad026f0 100644
@@ -1427,14 +1427,21 @@ int fw_env_open(struct env_opts *opts)
 	}
 
 	dev_current = 0;
-	if (flash_io(O_RDONLY)) {
+
+	if (!flash_io(O_RDONLY)) {
+		crc0 = crc32(0, (uint8_t *)environment.data, ENV_SIZE);
+		crc0_ok = (crc0 == *environment.crc);
+	} else if (have_redund_env) {
+		/*
+		 * to give the redundant env a chance, maybe it's good:
+		 * mark env crc0 invalid then test below if crc1 is ok
+		 */
+		crc0_ok = 0;
+	} else {
 		ret = -EIO;
 		goto open_cleanup;
 	}
 
-	crc0 = crc32(0, (uint8_t *)environment.data, ENV_SIZE);
-
-	crc0_ok = (crc0 == *environment.crc);
 	if (!have_redund_env) {
 		if (!crc0_ok) {
 			fprintf(stderr,
@@ -1462,8 +1469,10 @@ int fw_env_open(struct env_opts *opts)
 		 */
 		environment.image = addr1;
 		if (flash_io(O_RDONLY)) {
-			ret = -EIO;
-			goto open_cleanup;
+			crc1_ok = 0;
+		} else {
+			crc1 = crc32(0, (uint8_t *)redundant->data, ENV_SIZE);
+			crc1_ok = (crc1 == redundant->crc);
 		}
 
 		/* Check flag scheme compatibility */
@@ -1489,9 +1498,6 @@ int fw_env_open(struct env_opts *opts)
 			goto open_cleanup;
 		}
 
-		crc1 = crc32(0, (uint8_t *)redundant->data, ENV_SIZE);
-
-		crc1_ok = (crc1 == redundant->crc);
 		flag1 = redundant->flags;
 
 		if (crc0_ok && !crc1_ok) {
Signature · 1 line
2.17.1
#1 lore raw

PATCH 1/1 fw_printenv: Don't bail out directly after one env read error

Quoted 8 lines · Ioan-Adrian Ratiu

From: Joe Hershberger <[email protected]>

When using a redundant environment a read error should simply mean to not use that copy instead of giving up completely. The other copy may be just fine.

Hey Tom, can you pull this in?

Thanks,
-Joe

Quoted 64 lines
---
 tools/env/fw_env.c | 24 +++++++++++++++---------
 1 file changed, 15 insertions(+), 9 deletions(-)
tools/env/fw_env.c +15 -10
index a5d75958e1..3a5ad026f0 100644
@@ -1427,14 +1427,21 @@ int fw_env_open(struct env_opts *opts)
        }
 
        dev_current = 0;
-       if (flash_io(O_RDONLY)) {
+
+       if (!flash_io(O_RDONLY)) {
+               crc0 = crc32(0, (uint8_t *)environment.data, ENV_SIZE);
+               crc0_ok = (crc0 == *environment.crc);
+       } else if (have_redund_env) {
+               /*
+                * to give the redundant env a chance, maybe it's good:
+                * mark env crc0 invalid then test below if crc1 is ok
+                */
+               crc0_ok = 0;
+       } else {
                ret = -EIO;
                goto open_cleanup;
        }
 
-       crc0 = crc32(0, (uint8_t *)environment.data, ENV_SIZE);
-
-       crc0_ok = (crc0 == *environment.crc);
        if (!have_redund_env) {
                if (!crc0_ok) {
                        fprintf(stderr,
@@ -1462,8 +1469,10 @@ int fw_env_open(struct env_opts *opts)
                 */
                environment.image = addr1;
                if (flash_io(O_RDONLY)) {
-                       ret = -EIO;
-                       goto open_cleanup;
+                       crc1_ok = 0;
+               } else {
+                       crc1 = crc32(0, (uint8_t *)redundant->data, ENV_SIZE);
+                       crc1_ok = (crc1 == redundant->crc);
                }
 
                /* Check flag scheme compatibility */
@@ -1489,9 +1498,6 @@ int fw_env_open(struct env_opts *opts)
                        goto open_cleanup;
                }
 
-               crc1 = crc32(0, (uint8_t *)redundant->data, ENV_SIZE);
-
-               crc1_ok = (crc1 == redundant->crc);
                flag1 = redundant->flags;
 
                if (crc0_ok && !crc1_ok) {
--

2.17.1

_______________________________________________
U-Boot mailing list
U-Boot at lists.denx.de
https://lists.denx.de/listinfo/u-boot

#2 lore raw

PATCH 1/1 fw_printenv: Don't bail out directly after one env read error

Dear Joe,

Quoted 9 lines · In message <CANr=Z=atFzdNO6gNhMgopCHaQ-KXPGMfaOz2+_KCVrKwkMOhuw@mail.gmail.com>…
Quoted 7 lines

When using a redundant environment a read error should simply mean to not use that copy instead of giving up completely. The other copy may be just fine.

Hey Tom, can you pull this in?

NO! Please don't!!

NAK!!

This patch can lead to reading incorrect (old, no longer valid) values without any way for the user to see what is happening.

This must not be done!

Best regards,

Wolfgang Denk

Signature · 7 lines
DENX Software Engineering GmbH,      Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de
"There is nothing  so  deadly  as  not  to  hold  up  to  people  the
opportunity to do great and wonderful things, if we wish to stimulate
them in an active way."
- Dr. Harold Urey, Nobel Laureate in chemistry
#3 lore raw

PATCH 1/1 fw_printenv: Don't bail out directly after one env read error

Quoted 13 lines · Wolfgang Denk

Dear Joe,

Quoted 9 lines · In message <CANr=Z=atFzdNO6gNhMgopCHaQ-KXPGMfaOz2+_KCVrKwkMOhuw@mail.gmail.com>…
Quoted 7 lines

When using a redundant environment a read error should simply mean to not use that copy instead of giving up completely. The other copy may be just fine.

Hey Tom, can you pull this in?

Quoted 8 lines

NO! Please don't!!

NAK!!

This patch can lead to reading incorrect (old, no longer valid) values without any way for the user to see what is happening.

This must not be done!

I'm not 100% sure, after reading all of the code, if there's a problem. What we indeed do not want to do is be silent in seeing that the first environment location we read from failed. But AFAICT if flash_io returns non-zero we also output something useful to stderr, so it should be visible to the user that something went wrong. The next question is, if half of the redundant environment has failed, is the other half considered valid (so long as the crc passes) or would only the built-in be valid? I would think the other half is the valid one.

Signature · 8 lines
Tom
-------------- next part --------------
A non-text attachment was scrubbed...
Name: signature.asc
Type: application/pgp-signature
Size: 819 bytes
Desc: not available
URL: <http://lists.denx.de/pipermail/u-boot/attachments/20180629/3108a903/attachment.sig>
#4 lore raw

PATCH 1/1 fw_printenv: Don't bail out directly after one env read error

Dear Tom,

Quoted 7 lines · In message <20180629181550.GG18596@bill-the-cat> you wrote:
Quoted 5 lines

This patch can lead to reading incorrect (old, no longer valid) values without any way for the user to see what is happening.

This must not be done!

I'm not 100% sure, after reading all of the code, if there's a problem.

There is.

Quoted 4 lines

What we indeed do not want to do is be silent in seeing that the first environment location we read from failed. But AFAICT if flash_io returns non-zero we also output something useful to stderr, so it should be visible to the user that something went wrong.

But there is no indication about the problem in the return code, so any tools using this have no way to determine there was a problem.

Quoted 4 lines

The next question is,
if half of the redundant environment has failed, is the other half considered valid (so long as the crc passes) or would only the built-in be valid? I would think the other half is the valid one.

It may be valid, but it is still not what we want.

redundant environment is used to provide a fall-back in case of poblems when _writing_ the environment, i. e. like a power-off while a "saveenv" is running. The purpose is to make sute that even then we will always have a valid environment, with correct checksum.

But as soon as the saveenv has succesfully completed, we do not have to equal, exchangable copies - instead, we have one which holds the current data (and only this is what represents the "correct" state), and another copy, which holds the old state, i. e. which is obsolete.

Sielntly swapping the current and the obsolete data is a serious bug, which must never happen. It may be OK as part of some recovery procedure to limit the damage, but it must never ever go unnoticed.

Assume you switch to another boot device / boot partion as part of a system update procedure. Then booting the wrong system is definitely not what you want.

Please revert!

Best regards,

Wolfgang Denk

Signature · 4 lines
DENX Software Engineering GmbH,      Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de
It's not an optical illusion, it just looks like one.   -- Phil White
#5 lore raw

PATCH 1/1 fw_printenv: Don't bail out directly after one env read error

Quoted 13 lines · Wolfgang Denk

Dear Tom,

Quoted 7 lines · In message <20180629181550.GG18596@bill-the-cat> you wrote:
Quoted 5 lines

This patch can lead to reading incorrect (old, no longer valid) values without any way for the user to see what is happening.

This must not be done!

I'm not 100% sure, after reading all of the code, if there's a problem.

There is.

Quoted 7 lines
Quoted 4 lines

What we indeed do not want to do is be silent in seeing that the first environment location we read from failed. But AFAICT if flash_io returns non-zero we also output something useful to stderr, so it should be visible to the user that something went wrong.

But there is no indication about the problem in the return code, so any tools using this have no way to determine there was a problem.

Ah, true, thanks!

Quoted 22 lines
Quoted 4 lines

The next question is,
if half of the redundant environment has failed, is the other half considered valid (so long as the crc passes) or would only the built-in be valid? I would think the other half is the valid one.

It may be valid, but it is still not what we want.

redundant environment is used to provide a fall-back in case of poblems when _writing_ the environment, i. e. like a power-off while a "saveenv" is running. The purpose is to make sute that even then we will always have a valid environment, with correct checksum.

But as soon as the saveenv has succesfully completed, we do not have to equal, exchangable copies - instead, we have one which holds the current data (and only this is what represents the "correct" state), and another copy, which holds the old state, i. e. which is obsolete.

Sielntly swapping the current and the obsolete data is a serious bug, which must never happen. It may be OK as part of some recovery procedure to limit the damage, but it must never ever go unnoticed.

Quoted 5 lines

Assume you switch to another boot device / boot partion as part of a system update procedure. Then booting the wrong system is definitely not what you want.

Please revert!

Joe, Ioan-Adrian, I've reverted this. Please re-work the changes such that the use case you need to support is handled in some manner (likely a new flag being passed to fw_printenv/setenv) such that the current behavior is still the default, given Wolfgang's explanations above, thanks!

Signature · 8 lines
Tom
-------------- next part --------------
A non-text attachment was scrubbed...
Name: signature.asc
Type: application/pgp-signature
Size: 819 bytes
Desc: not available
URL: <http://lists.denx.de/pipermail/u-boot/attachments/20180702/735ee1aa/attachment.sig>
#6 lore raw
In reply to Ioan-Adrian Ratiu
Quoted 8 lines · Ioan-Adrian Ratiu

From: Joe Hershberger <[email protected]>

When using a redundant environment a read error should simply mean to not use that copy instead of giving up completely. The other copy may be just fine.

Applied to u-boot/master, thanks!

Signature · 8 lines
Tom
-------------- next part --------------
A non-text attachment was scrubbed...
Name: signature.asc
Type: application/pgp-signature
Size: 819 bytes
Desc: not available
URL: <http://lists.denx.de/pipermail/u-boot/attachments/20180627/67d8d7aa/attachment.sig>
#7 lore raw

Dear Tom,

Quoted 11 lines · In message <[email protected]> you wrote:
Quoted 9 lines

From: Joe Hershberger <[email protected]>
=20
When using a redundant environment a read error should simply mean to not use that copy instead of giving up completely. The other copy may be just fine.
=20

Applied to u-boot/master, thanks!

Please revert. This is introducing a source for nasty, almost impossible to detect bugs!

Read errors must never be ignored.

Best regards,

Wolfgang Denk

Signature · 5 lines
DENX Software Engineering GmbH,      Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de
What we anticipate seldom occurs;  what  we  least  expect  generally
happens.                                          - Bengamin Disraeli
#8 lore raw

PATCH 1/1 fw_printenv: Don't bail out directly after one env read error

In reply to Ioan-Adrian Ratiu

Dear Adrian,

Quoted 5 lines · In message <[email protected]> you wrote:

From: Joe Hershberger <[email protected]>

When using a redundant environment a read error should simply mean to not use that copy instead of giving up completely. The other copy may be just fine.

While the general idea is fine, I think we should NOT automatically read data from the backup copy, at least not without clearly letting the user know about this - and such notification should also work in automated scripts or cod calling these routines, so a plain warning message is NOT sufficient.

I suggest that the default remains as is: environment read errors cause an error return of this function.

But it would probably nice for recovery purposes or such to add an option to switch into some "permissive" mode - here the fall-back to the redundant copy would be permitted, and the return code should indicate what happened (read of primary env copy OK; read failed, but redundant copy could ne read; all read attemtps failed).

Thanks!

Best regards,

Wolfgang Denk