Meson8/Meson8b: introduce a HHI syscon node
Subsystems (4)
Martin Blumenstingl
reviewercover Meson8/Meson8b: introduce a HHI syscon node
The Meson8/Meson8b/Meson8m2 SoCs are suffering from a similar problem as the GXBB/GXL/GXM SoCs (see the GX series from Jerome: [0]):
There is a register area called "HHI" which is used for multiple IP blocks of the SoC:
- the system clock controller
- a few reset lines (there is a separate reset controller, these reset lines are not part of the other reset controller). this reset controller is currently implemented in the clock controller driver
- a HDMI controller
- temperature sensor calibration data (by "data" I really mean data, the ADC driver has four bits for the TSC data in it's own register space, however on Meson8b and Meson8m2 there is a fifth TSC bit which is stored in the HHI register area)
The first three could be implemented with a single node (either in one big driver, or using a MFD driver which would register function- specific drivers).
However, the TSC data is a big problem, because the ADC has it's own set of registers but needs to write one bit in the HHI register area.
NOTE: this series has multiple dependencies:
- the clock controller changes depend "meson8b: add the CPU_DIV16 clock for the ARM TWD" as well as "meson8b: register the clock controller early" [2]
- the dts changes depend on "fix clock controller register size on Meson8/Meson8b" [3]
[0] http://lists.infradead.org/pipermail/linux-amlogic/2018-March/006733.html
[1] http://lists.infradead.org/pipermail/linux-amlogic/2018-July/007890.html
[2] http://lists.infradead.org/pipermail/linux-amlogic/2018-July/007900.html
[3] http://lists.infradead.org/pipermail/linux-amlogic/2018-July/007897.html
Martin Blumenstingl (3):
dt-bindings: clock: meson8b: use the registers from the HHI syscon
clk: meson: meson8b: use the HHI syscon if available
ARM: dts: meson: switch the clock controller to the HHI register area
.../bindings/clock/amlogic,meson8b-clkc.txt | 13 ++++------ arch/arm/boot/dts/meson.dtsi | 5 ++++ arch/arm/boot/dts/meson8.dtsi | 15 ++++++------ arch/arm/boot/dts/meson8b.dtsi | 15 ++++++------ drivers/clk/meson/meson8b.c | 24 ++++++++++++------- 5 files changed, 41 insertions(+), 31 deletions(-)
Signature · 1 line
2.18.0
Martin Blumenstingl
reviewerPATCH 1/3 dt-bindings: clock: meson8b: use the registers from the HHI syscon
The clock controller on Meson8/Meson8m2 and Meson8b is part of a register region called "HHI". This register area contains more functionality than just a clock controller:
- the clock controller
- some reset controller bits
- temperature sensor calibration data (on Meson8b and Meson8m2 only)
- HDMI controller
The HHI register area may be accessed concurrently. Allow this by using a "system controller" as parent node.
--- .../bindings/clock/amlogic,meson8b-clkc.txt | 13 +++++-------- 1 file changed, 5 insertions(+), 8 deletions(-)
Documentation/devicetree/bindings/clock/amlogic,meson8b-clkc.txt +5 -8
@@ -9,15 +9,13 @@ Required Properties: - "amlogic,meson8-clkc" for Meson8 (S802) SoCs - "amlogic,meson8b-clkc" for Meson8 (S805) SoCs - "amlogic,meson8m2-clkc" for Meson8m2 (S812) SoCs -- reg: it must be composed by two tuples: - 0) physical base address of the xtal register and length of memory - mapped region. - 1) physical base address of the clock controller and length of memory - mapped region. - - #clock-cells: should be 1. - #reset-cells: should be 1. +Parent node should have the following properties : +- compatible: "syscon", "simple-mfd" +- reg: base address and size of the HHI system control register space. + Each clock is assigned an identifier and client nodes can use this identifier to specify the clock which they consume. All available clocks are defined as preprocessor macros in the dt-bindings/clock/meson8b-clkc.h header and can be
@@ -30,9 +28,8 @@ device tree sources). Example: Clock controller node: - clkc: clock-controller at c1104000 { + clkc: clock-controller { compatible = "amlogic,meson8b-clkc"; - reg = <0xc1108000 0x4>, <0xc1104000 0x460>; #clock-cells = <1>; #reset-cells = <1>; };
Signature · 1 line
2.18.0
Rob Herring
maintainerPATCH 1/3 dt-bindings: clock: meson8b: use the registers from the HHI syscon
Quoted 10 lines · Martin Blumenstingl
The clock controller on Meson8/Meson8m2 and Meson8b is part of a register region called "HHI". This register area contains more functionality than just a clock controller:
- the clock controller
- some reset controller bits
- temperature sensor calibration data (on Meson8b and Meson8m2 only)
- HDMI controllerThe HHI register area may be accessed concurrently. Allow this by using a "system controller" as parent node.
Why? A single node can be a provider of multiple things. Maybe the HDMI should be a child since it will involve graph nodes, but the rest can be one node. There should be numerous examples of blocks that are clock and reset controllers.
Quoted 15 lines
Signed-off-by Martin Blumenstingl <[email protected]>--- .../bindings/clock/amlogic,meson8b-clkc.txt | 13 +++++-------- 1 file changed, 5 insertions(+), 8 deletions(-)Documentation/devicetree/bindings/clock/amlogic,meson8b-clkc.txt +0
-1@@ -9,15 +9,13 @@ Required Properties: - "amlogic,meson8-clkc" for Meson8 (S802) SoCs - "amlogic,meson8b-clkc" for Meson8 (S805) SoCs - "amlogic,meson8m2-clkc" for Meson8m2 (S812) SoCs -- reg: it must be composed by two tuples:
Documentation/devicetree/bindings/clock/amlogic,meson8b-clkc.txt Required Properties: · line 16
Quoted 10 lines
Documentation/devicetree/bindings/clock/amlogic,meson8b-clkc.txt +2
-5- 0) physical base address of the xtal register and length of memory - mapped region. - 1) physical base address of the clock controller and length of memory - mapped region. - - #clock-cells: should be 1. - #reset-cells: should be 1. +Parent node should have the following properties : +- compatible: "syscon", "simple-mfd"
These 2 compatibles alone are not valid.
Quoted 19 lines
Documentation/devicetree/bindings/clock/amlogic,meson8b-clkc.txt +3
-2+- reg: base address and size of the HHI system control register space. + Each clock is assigned an identifier and client nodes can use this identifier to specify the clock which they consume. All available clocks are defined as preprocessor macros in the dt-bindings/clock/meson8b-clkc.h header and can be@@ -30,9 +28,8 @@ device tree sources). Example: Clock controller node: - clkc: clock-controller at c1104000 { + clkc: clock-controller { compatible = "amlogic,meson8b-clkc"; - reg = <0xc1108000 0x4>, <0xc1104000 0x460>; #clock-cells = <1>; #reset-cells = <1>; };Signature · 1 line
2.18.0
Martin Blumenstingl
reviewerPATCH 1/3 dt-bindings: clock: meson8b: use the registers from the HHI syscon
Hi Rob,
Quoted 10 lines · Rob Herring
Quoted 8 lines · Martin Blumenstingl
The clock controller on Meson8/Meson8m2 and Meson8b is part of a register region called "HHI". This register area contains more functionality than just a clock controller:
- the clock controller
- some reset controller bits
- temperature sensor calibration data (on Meson8b and Meson8m2 only)
- HDMI controller
Quoted 7 lines
Quoted 2 lines
The HHI register area may be accessed concurrently. Allow this by using a "system controller" as parent node.
Why? A single node can be a provider of multiple things. Maybe the HDMI should be a child since it will involve graph nodes, but the rest can be one node. There should be numerous examples of blocks that are clock and reset controllers.
I understand that a node can provide multiple "things" - currently it's a clock controller and a reset controller
the HDMI controller could also be integrated in a similar way
however, I do not know how to access the temperature sensor calibration data there is an ADC - one of it's channel has access to a temperature sensor this ADC is located at CBUS offset 0x8680 and we already have a driver for it (meson-saradc)
my problem is that the temperature sensor has to be calibrated - this is done by:
- read data from efuse
- write 4 bits of calibration data to some register in the ADC's register space
- write a 5th bit of calibration data to a (seemingly random) register in the HHI register space
(if one of the 5 bits is not written to it's correct location then the temperature sensor reads bogus values)
I am not sure how to handle this without passing the HHI region to the meson-saradc driver and letting that initialize all the temperature calibration data bits (in it's own register space as well as the HHI register space)
do you have any suggestion here?
Quoted 23 lines
Quoted 23 lines
Signed-off-by Martin Blumenstingl <[email protected]>--- .../bindings/clock/amlogic,meson8b-clkc.txt | 13 +++++-------- 1 file changed, 5 insertions(+), 8 deletions(-)Documentation/devicetree/bindings/clock/amlogic,meson8b-clkc.txt +0
-6@@ -9,15 +9,13 @@ Required Properties: - "amlogic,meson8-clkc" for Meson8 (S802) SoCs - "amlogic,meson8b-clkc" for Meson8 (S805) SoCs - "amlogic,meson8m2-clkc" for Meson8m2 (S812) SoCs -- reg: it must be composed by two tuples: - 0) physical base address of the xtal register and length of memory - mapped region. - 1) physical base address of the clock controller and length of memory - mapped region. - - #clock-cells: should be 1. - #reset-cells: should be 1.
Quoted 4 lines
Documentation/devicetree/bindings/clock/amlogic,meson8b-clkc.txt Required Properties: · line 16
Quoted 2 lines
Documentation/devicetree/bindings/clock/amlogic,meson8b-clkc.txt +2
-0+Parent node should have the following properties : +- compatible: "syscon", "simple-mfd"These 2 compatibles alone are not valid.
so I should add (for example) "amlogic,meson8b-hhi-sysctrl" as first compatible? so the result would be: compatible = "amlogic,meson8b-hhi-sysctrl", "syscon", "simple-mfd";
Regards
Martin
PATCH 1/3 dt-bindings: clock: meson8b: use the registers from the HHI syscon
Hi Rob, Martin,
Quoted 37 lines · Martin Blumenstingl
Hi Rob,
Quoted 10 lines · Rob Herring
Quoted 8 lines · Martin Blumenstingl
The clock controller on Meson8/Meson8m2 and Meson8b is part of a register region called "HHI". This register area contains more functionality than just a clock controller:
- the clock controller
- some reset controller bits
- temperature sensor calibration data (on Meson8b and Meson8m2 only)
- HDMI controllerQuoted 7 lines
Quoted 2 lines
The HHI register area may be accessed concurrently. Allow this by using a "system controller" as parent node.
Why? A single node can be a provider of multiple things. Maybe the HDMI should be a child since it will involve graph nodes, but the rest can be one node. There should be numerous examples of blocks that are clock and reset controllers.
I understand that a node can provide multiple "things" - currently it's a clock controller and a reset controller
the HDMI controller could also be integrated in a similar wayhowever, I do not know how to access the temperature sensor calibration data there is an ADC - one of it's channel has access to a temperature sensor this ADC is located at CBUS offset
0x8680and we already have a driver for it (meson-saradc)
my problem is that the temperature sensor has to be calibrated - this is done by:
- read data from efuse
- write 4 bits of calibration data to some register in the ADC's register space
- write a 5th bit of calibration data to a (seemingly random) register in the HHI register space
(if one of the 5 bits is not written to it's correct location then the temperature sensor reads bogus values)
Quoted 5 lines
I am not sure how to handle this without passing the HHI region to the meson-saradc driver and letting that initialize all the temperature calibration data bits (in it's own register space as well as the HHI register space)
do you have any suggestion here?
The clock controller node was badly represented from the beginning, the HHI register zone *is* a "system control" zone with a lot of different registers controller the system, including all the EE clocks, *some* HDMI PHY settings, *some* Video DAC settings, *some* memory power control...
Thus, the clock controller *is* entirely in the HHI registers space, but the HHI register space should be used by other nodes for control some part of the SoCs. This is why we decided to model the HHI zone as a "syscon" to permit other node to have access to these registers and "simple-mfd" to expose the *big* feature of the HHI : the clock controller.
We are migrating the Meson8 because we already migrated the GX and because the AXG family was pushed like this (and acked like this), so it's common sense to align the 3 families because they share the same characteristics here.
Neil
Quoted 24 lines
Quoted 24 lines
Quoted 24 lines
Signed-off-by Martin Blumenstingl <[email protected]>--- .../bindings/clock/amlogic,meson8b-clkc.txt | 13 +++++-------- 1 file changed, 5 insertions(+), 8 deletions(-)Documentation/devicetree/bindings/clock/amlogic,meson8b-clkc.txt +0
-6@@ -9,15 +9,13 @@ Required Properties: - "amlogic,meson8-clkc" for Meson8 (S802) SoCs - "amlogic,meson8b-clkc" for Meson8 (S805) SoCs - "amlogic,meson8m2-clkc" for Meson8m2 (S812) SoCs -- reg: it must be composed by two tuples: - 0) physical base address of the xtal register and length of memory - mapped region. - 1) physical base address of the clock controller and length of memory - mapped region. - - #clock-cells: should be 1. - #reset-cells: should be 1.
Quoted 7 lines
Quoted 4 lines
Documentation/devicetree/bindings/clock/amlogic,meson8b-clkc.txt Required Properties: · line 16
Quoted 2 lines
Documentation/devicetree/bindings/clock/amlogic,meson8b-clkc.txt +2
-0+Parent node should have the following properties : +- compatible: "syscon", "simple-mfd"These 2 compatibles alone are not valid.
so I should add (for example) "amlogic,meson8b-hhi-sysctrl" as first compatible? so the result would be: compatible = "amlogic,meson8b-hhi-sysctrl", "syscon", "simple-mfd";
yes, we used a specific compatible for GX and AXG like this.
Question, what should be the order between "syscon" and "simple-mfd" ?
Quoted 5 lines
Regards
Martin
Martin Blumenstingl
reviewerPATCH 1/3 dt-bindings: clock: meson8b: use the registers from the HHI syscon
Hi Rob,
Quoted 52 lines · Neil Armstrong
Hi Rob, Martin,
Quoted 37 lines · Martin Blumenstingl
Hi Rob,
Quoted 10 lines · Rob Herring
Quoted 8 lines · Martin Blumenstingl
The clock controller on Meson8/Meson8m2 and Meson8b is part of a register region called "HHI". This register area contains more functionality than just a clock controller:
- the clock controller
- some reset controller bits
- temperature sensor calibration data (on Meson8b and Meson8m2 only)
- HDMI controllerQuoted 7 lines
Quoted 2 lines
The HHI register area may be accessed concurrently. Allow this by using a "system controller" as parent node.
Why? A single node can be a provider of multiple things. Maybe the HDMI should be a child since it will involve graph nodes, but the rest can be one node. There should be numerous examples of blocks that are clock and reset controllers.
I understand that a node can provide multiple "things" - currently it's a clock controller and a reset controller
the HDMI controller could also be integrated in a similar wayhowever, I do not know how to access the temperature sensor calibration data there is an ADC - one of it's channel has access to a temperature sensor this ADC is located at CBUS offset
0x8680and we already have a driver for it (meson-saradc)
my problem is that the temperature sensor has to be calibrated - this is done by:
- read data from efuse
- write 4 bits of calibration data to some register in the ADC's register space
- write a 5th bit of calibration data to a (seemingly random) register in the HHI register space
(if one of the 5 bits is not written to it's correct location then the temperature sensor reads bogus values)Quoted 5 lines
I am not sure how to handle this without passing the HHI region to the meson-saradc driver and letting that initialize all the temperature calibration data bits (in it's own register space as well as the HHI register space)
do you have any suggestion here?The clock controller node was badly represented from the beginning, the HHI register zone *is* a "system control" zone with a lot of different registers controller the system, including all the EE clocks, *some* HDMI PHY settings, *some* Video DAC settings, *some* memory power control...
Quoted 5 lines
Thus, the clock controller *is* entirely in the HHI registers space, but the HHI register space should be used by other nodes for control some part of the SoCs. This is why we decided to model the HHI zone as a "syscon" to permit other node to have access to these registers and "simple-mfd" to expose the *big* feature of the HHI : the clock controller.
does our (Neil's and mine) explanation make sense to you? I understand your point that a DT node can provide multiple "things". this is the case on the Meson HHI region, but in addition to that the HHI region contains additional bits for other IP blocks. so my understanding is that using a syscon here is fine
Quoted 34 lines
We are migrating the Meson8 because we already migrated the GX and because the AXG family was pushed like this (and acked like this), so it's common sense to align the 3 families because they share the same characteristics here.
Neil
Quoted 28 lines
Quoted 28 lines
Quoted 16 lines
Signed-off-by Martin Blumenstingl <[email protected]>--- .../bindings/clock/amlogic,meson8b-clkc.txt | 13 +++++-------- 1 file changed, 5 insertions(+), 8 deletions(-)Documentation/devicetree/bindings/clock/amlogic,meson8b-clkc.txt +0
-1@@ -9,15 +9,13 @@ Required Properties: - "amlogic,meson8-clkc" for Meson8 (S802) SoCs - "amlogic,meson8b-clkc" for Meson8 (S805) SoCs - "amlogic,meson8m2-clkc" for Meson8m2 (S812) SoCs -- reg: it must be composed by two tuples:Documentation/devicetree/bindings/clock/amlogic,meson8b-clkc.txt Required Properties: · line 16
Quoted 10 lines
Documentation/devicetree/bindings/clock/amlogic,meson8b-clkc.txt +2
-5- 0) physical base address of the xtal register and length of memory - mapped region. - 1) physical base address of the clock controller and length of memory - mapped region. - - #clock-cells: should be 1. - #reset-cells: should be 1. +Parent node should have the following properties : +- compatible: "syscon", "simple-mfd"These 2 compatibles alone are not valid.
Quoted 7 lines
Quoted 3 lines
so I should add (for example) "amlogic,meson8b-hhi-sysctrl" as first compatible? so the result would be: compatible = "amlogic,meson8b-hhi-sysctrl", "syscon", "simple-mfd";
yes, we used a specific compatible for GX and AXG like this.
Question, what should be the order between "syscon" and "simple-mfd" ?
for consistency I will go with whatever the GX and AXG dt-bindings use
Regards
Martin
Stephen Boyd
maintainerPATCH 1/3 dt-bindings: clock: meson8b: use the registers from the HHI syscon
Quoting Martin Blumenstingl (2018-08-12 11:35:17)
Quoted 60 lines
Hi Rob,
Quoted 52 lines · Neil Armstrong
Hi Rob, Martin,
Quoted 37 lines · Martin Blumenstingl
Hi Rob,
Quoted 10 lines · Rob Herring
Quoted 8 lines · Martin Blumenstingl
The clock controller on Meson8/Meson8m2 and Meson8b is part of a register region called "HHI". This register area contains more functionality than just a clock controller:
- the clock controller
- some reset controller bits
- temperature sensor calibration data (on Meson8b and Meson8m2 only)
- HDMI controllerQuoted 7 lines
Quoted 2 lines
The HHI register area may be accessed concurrently. Allow this by using a "system controller" as parent node.
Why? A single node can be a provider of multiple things. Maybe the HDMI should be a child since it will involve graph nodes, but the rest can be one node. There should be numerous examples of blocks that are clock and reset controllers.
I understand that a node can provide multiple "things" - currently it's a clock controller and a reset controller
the HDMI controller could also be integrated in a similar wayhowever, I do not know how to access the temperature sensor calibration data there is an ADC - one of it's channel has access to a temperature sensor this ADC is located at CBUS offset
0x8680and we already have a driver for it (meson-saradc)
my problem is that the temperature sensor has to be calibrated - this is done by:
- read data from efuse
- write 4 bits of calibration data to some register in the ADC's register space
- write a 5th bit of calibration data to a (seemingly random) register in the HHI register space
(if one of the 5 bits is not written to it's correct location then the temperature sensor reads bogus values)Quoted 5 lines
I am not sure how to handle this without passing the HHI region to the meson-saradc driver and letting that initialize all the temperature calibration data bits (in it's own register space as well as the HHI register space)
do you have any suggestion here?The clock controller node was badly represented from the beginning, the HHI register zone *is* a "system control" zone with a lot of different registers controller the system, including all the EE clocks, *some* HDMI PHY settings, *some* Video DAC settings, *some* memory power control...
Quoted 5 lines
Thus, the clock controller *is* entirely in the HHI registers space, but the HHI register space should be used by other nodes for control some part of the SoCs. This is why we decided to model the HHI zone as a "syscon" to permit other node to have access to these registers and "simple-mfd" to expose the *big* feature of the HHI : the clock controller.
Quoted 6 lines
does our (Neil's and mine) explanation make sense to you? I understand your point that a DT node can provide multiple "things". this is the case on the Meson HHI region, but in addition to that the HHI region contains additional bits for other IP blocks. so my understanding is that using a syscon here is fine
I'm dropping this from my review queue because nobody has replied in many weeks. I think Rob wants people to move away from syscon so if you can't do that then we need good reasons. I recommend putting those reasons in the commit text and resending this series.
Jerome Brunet
maintainerPATCH 1/3 dt-bindings: clock: meson8b: use the registers from the HHI syscon
Quoted 18 lines · Stephen Boyd
Quoted 11 lines
Quoted 10 lines
The clock controller node was badly represented from the beginning, the HHI register zone *is* a "system control" zone with a lot of different registers controller the system, including all the EE clocks, *some* HDMI PHY settings, *some* Video DAC settings, *some* memory power control...
Thus, the clock controller *is* entirely in the HHI registers space, but the HHI register space should be used by other nodes for control some part of the SoCs. This is why we decided to model the HHI zone as a "syscon" to permit other node to have access to these registers and "simple-mfd" to expose the *big* feature of the HHI : the clock controller.
Quoted 6 lines
does our (Neil's and mine) explanation make sense to you? I understand your point that a DT node can provide multiple "things". this is the case on the Meson HHI region, but in addition to that the HHI region contains additional bits for other IP blocks. so my understanding is that using a syscon here is fine
Quoted 4 lines
I'm dropping this from my review queue because nobody has replied in many weeks. I think Rob wants people to move away from syscon so if you can't do that then we need good reasons. I recommend putting those reasons in the commit text and resending this series.
Doubling down on what Neil and Martin already reported:
When this clock controller what initially added, It was thought that the HHI register space only contained clocks and resets, which we know how to handle in a single driver and does not mandate a 'syscon'
Since then, we learn that HHI has more than just clocks and reset. This is the case on every amlogic platform, which is why we already moved gxbb/gxl to syscon. axg arrived later and used this model directly. Meson8 did not mandate the change so far. We tried to avoid this mess as long as it was not absolutely necessary.
This particular platform (meson8) has an ADC block with is own registers space. The ADC comes with temperature sensor which has a few compensation values. 4 of these compensation values are in the ADC register space, the 5th is apparently in the HHI... HW is what it is ...
Bottom line is, HHI is a typical system controller which need to be access by several devices. We are not particularly fond of syscon either but there are still some situations were this is cleanest solution, AFAIK.
Jerome
Martin Blumenstingl
reviewerPATCH 2/3 clk: meson: meson8b: use the HHI syscon if available
In reply to Martin BlumenstinglThe clock controller is located in a register range (called "HHI") which contains more than just registers for the clock controller. Known consumers of the HHI register range are:
- the clock controller
- a reset controller
- temperature sensor calibration (TSC) data (Meson8b and Meson8m2 only)
- HDMI controller
Get the regmap from the parent (HHI syscon) node to support all functionality of the HHI register range. Backwards compatibility with old .dtbs is ensured by falling back to parsing the registers just like before this change.
--- drivers/clk/meson/meson8b.c | 24 +++++++++++++++--------- 1 file changed, 15 insertions(+), 9 deletions(-)
drivers/clk/meson/meson8b.c +15 -9
@@ -10,6 +10,7 @@#include <linux/clk.h> #include <linux/clk-provider.h> #include <linux/init.h> +#include <linux/mfd/syscon.h> #include <linux/of_address.h> #include <linux/reset-controller.h> #include <linux/slab.h>
@@ -1109,16 +1110,21 @@ static void __init meson8b_clkc_init(struct device_node *np)struct regmap *map;int i, ret; -/* Generic clocks, PLLs and some of the reset-bits */ - clk_base =of_iomap (np,1 ); -if (!clk_base) { -pr_err ("%s: Unable to map clk base\n" , __func__); -return ; - } + map =syscon_node_to_regmap (of_get_parent (np)); +if (IS_ERR (map)) { +pr_info ("failed to get HHI regmap - Trying obsolete regs\n" ); - map =regmap_init_mmio (NULL , clk_base, &clkc_regmap_config); -if (IS_ERR (map)) -return ; +/* Generic clocks, PLLs and some of the reset-bits */ + clk_base =of_iomap (np,1 ); +if (!clk_base) { +pr_err ("%s: Unable to map clk base\n" , __func__); +return ; + } + + map =regmap_init_mmio (NULL , clk_base, &clkc_regmap_config); +if (IS_ERR (map)) +return ; + } rstc =kzalloc (sizeof (*rstc),GFP_KERNEL );if (!rstc)
Signature · 1 line
2.18.0
Martin Blumenstingl
reviewerPATCH 3/3 ARM: dts: meson: switch the clock controller to the HHI register area
In reply to Martin BlumenstinglThe clock controller on Meson8/Meson8m2 and Meson8b is part of a register region called "HHI". This register area contains more functionality than just a clock controller:
- the clock controller
- some reset controller bits
- temperature sensor calibration data (on Meson8b and Meson8m2 only)
- HDMI controller
Allow access to this HHI register area as "system controller". Also migrate the Meson8 and Meson8b clock controllers to this new node.
--- arch/arm/boot/dts/meson.dtsi | 5 +++++ arch/arm/boot/dts/meson8.dtsi | 15 ++++++++------- arch/arm/boot/dts/meson8b.dtsi | 15 ++++++++------- 3 files changed, 21 insertions(+), 14 deletions(-)
arch/arm/boot/dts/meson.dtsi +5 -0
@@ -80,6 +80,11 @@ #size-cells = <1>; ranges = <0x0 0xc1100000 0x200000>; + hhi: system-controller at 4000 { + compatible = "syscon", "simple-mfd"; + reg = <0x4000 0x400>; + }; + assist: assist at 7c00 { compatible = "amlogic,meson-mx-assist", "syscon"; reg = <0x7c00 0x200>;
arch/arm/boot/dts/meson8.dtsi +8 -7
@@ -190,13 +190,6 @@ }; &cbus { - clkc: clock-controller at 4000 { - #clock-cells = <1>; - #reset-cells = <1>; - compatible = "amlogic,meson8-clkc"; - reg = <0x8000 0x4>, <0x4000 0x400>; - }; - reset: reset-controller at 4404 { compatible = "amlogic,meson8b-reset"; reg = <0x4404 0x9c>;
@@ -323,6 +316,14 @@ status = "okay"; }; +&hhi { + clkc: clock-controller { + compatible = "amlogic,meson8-clkc"; + #clock-cells = <1>; + #reset-cells = <1>; + }; +}; + &hwrng { compatible = "amlogic,meson8-rng", "amlogic,meson-rng"; clocks = <&clkc CLKID_RNG0>;
arch/arm/boot/dts/meson8b.dtsi +8 -7
@@ -159,13 +159,6 @@ }; &cbus { - clkc: clock-controller at 4000 { - #clock-cells = <1>; - #reset-cells = <1>; - compatible = "amlogic,meson8b-clkc"; - reg = <0x8000 0x4>, <0x4000 0x400>; - }; - reset: reset-controller at 4404 { compatible = "amlogic,meson8b-reset"; reg = <0x4404 0x9c>;
@@ -268,6 +261,14 @@ status = "okay"; }; +&hhi { + clkc: clock-controller { + compatible = "amlogic,meson8-clkc"; + #clock-cells = <1>; + #reset-cells = <1>; + }; +}; + &hwrng { compatible = "amlogic,meson8b-rng", "amlogic,meson-rng"; clocks = <&clkc CLKID_RNG0>;
Signature · 1 line
2.18.0
cover Meson8/Meson8b: introduce a HHI syscon node
In reply to Martin BlumenstinglQuoted 39 lines · Martin Blumenstingl
The Meson8/Meson8b/Meson8m2 SoCs are suffering from a similar problem as the GXBB/GXL/GXM SoCs (see the GX series from Jerome: [0]):
There is a register area called "HHI" which is used for multiple IP blocks of the SoC:
- the system clock controller
- a few reset lines (there is a separate reset controller, these reset lines are not part of the other reset controller). this reset controller is currently implemented in the clock controller driver
- a HDMI controller
- temperature sensor calibration data (by "data" I really mean data, the ADC driver has four bits for the TSC data in it's own register space, however on Meson8b and Meson8m2 there is a fifth TSC bit which is stored in the HHI register area)The first three could be implemented with a single node (either in one big driver, or using a MFD driver which would register function- specific drivers).
However, the TSC data is a big problem, because the ADC has it's own set of registers but needs to write one bit in the HHI register area.NOTE: this series has multiple dependencies:
- the clock controller changes depend "meson8b: add theCPU_DIV16clock for the ARM TWD" as well as "meson8b: register the clock controller early" [2]
- the dts changes depend on "fix clock controller register size on Meson8/Meson8b" [3][0] http://lists.infradead.org/pipermail/linux-amlogic/2018-March/006733.html
[1] http://lists.infradead.org/pipermail/linux-amlogic/2018-July/007890.html
[2] http://lists.infradead.org/pipermail/linux-amlogic/2018-July/007900.html
[3] http://lists.infradead.org/pipermail/linux-amlogic/2018-July/007897.htmlMartin Blumenstingl (3):
dt-bindings: clock: meson8b: use the registers from the HHI syscon
clk: meson: meson8b: use the HHI syscon if available
ARM: dts: meson: switch the clock controller to the HHI register area
Quoted 7 lines
.../bindings/clock/amlogic,meson8b-clkc.txt | 13 ++++------ arch/arm/boot/dts/meson.dtsi | 5 ++++ arch/arm/boot/dts/meson8.dtsi | 15 ++++++------ arch/arm/boot/dts/meson8b.dtsi | 15 ++++++------ drivers/clk/meson/meson8b.c | 24 ++++++++++++------- 5 files changed, 41 insertions(+), 31 deletions(-)
For the whole serie, it follow the same switch as GX so :