Skip to contentSkip to conversation

cpuset: Enable cpuset controller in default hierarchy

PATCH Superseded Waiman Long 2 participants 16 messages Aug 27, 2018 – Oct 2, 2018

Subsystems (3)

v12 of 15 Superseded Latest is v15 →

lore
Share & tools
lore

Waiman Long

author maintainer
#0 lore raw

v12 cover cpuset: Enable cpuset controller in default hierarchy

v12:
- Take out the debugging patch to print partitions.
- Add a patch to force turning off partition flag if newly modified CPU list doesn't meet the requirement of being a partition root.
- Remove some unneeded checking code in update_reserved_cpumask().

v11:
- Change the "domain_root" name to "partition" as suggested by Peter and update the documentation and code accordingly.
- Remove the dying cgroup check in update_reserved_cpus() as the check may not be needed after all.
- Document the effect of losing CPU affinity after offling all the cpus in a partition.
- There is no other major code changes in this version.

v10:
- Remove the cpuset.sched.load_balance patch for now as it may not be that useful.
- Break the large patch 2 into smaller patches to make them a bit easier to review.
- Test and fix issues related to changing "cpuset.cpus" and cpu online/offline in a domain root.
- Rename isolated_cpus to reserved_cpus as this cpumask holds CPUs reserved for child sched domains.
- Rework the scheduling domain debug printing code in the last patch.
- Document update to the newly moved Documentation/admin-guide/cgroup-v2.rst.

v9:
- Rename cpuset.sched.domain to cpuset.sched.domain_root to better identify its purpose as the root of a new scheduling domain or partition.
- Clarify in the document about the purpose of domain_root and load_balance. Using domain_root is th only way to create new partition.
- Fix a lockdep warning in update_isolated_cpumask() function.
- Add a new patch to eliminate call to generate_sched_domains() for v2 when a change in cpu list does not touch a domain_root.

v9 patch: https://lkml.org/lkml/2018/5/29/507
v10 patch: https://lkml.org/lkml/2018/6/18/3
v11 patch: https://lkml.org/lkml/2018/6/24/30

The purpose of this patchset is to provide a basic set of cpuset control files for cgroup v2. This basic set includes the non-root "cpus", "mems" and "sched.partition". The "cpus.effective" and "mems.effective" will appear in all cpuset-enabled cgroups.

The new control file that is unique to v2 is "sched.partition". It is a boolean flag file that designates if a cgroup is the root of a new scheduling domain or partition with its own set of unique list of CPUs from scheduling perspective disjointed from other partitions. The root cgroup is always a partition root. Multiple levels of partitions are supported with some limitations. So a container partition root can behave like a real root.

When a partition root cgroup is removed, its list of exclusive CPUs will be returned to the parent's cpus.effective automatically.

A container root can be a partition root with sub-partitions created underneath it. One difference from the real root is that the "cpuset.sched.partition" flag isn't present in the real root, but is present in a container root. This is also true for other cpuset control files as well as those from the other controllers. This is a general issue that is not going to be addressed here in this patchset.

This patchset does not exclude the possibility of adding more features in the future after careful consideration.

Patch 1 enables cpuset in cgroup v2 with cpus, mems and their effective counterparts.

Patch 2 adds a new "sched.partition" control file for setting up multiple scheduling domains or partitions. A partition root implies cpu_exclusive.

Patch 3 handles the proper deletion of a partition root cgroup by turning off the partition flag automatically before deletion.

Patch 4 allows "cpuset.cpus" of a partition root cgroup to be changed subject to certain constraints.

Patch 5 makes the hotplug code deal with partition root properly.

Patch 6 updates the scheduling domain genaration code to work with the new domain root feature.

Patch 7 exposes cpus.effective and mems.effective to the root cgroup as enabling child scheduling domains will take CPUs away from the root cgroup. So it will be nice to monitor what CPUs are left there.

Patch 8 eliminates the need to rebuild sched domains for v2 if cpu list changes occur to non-domain root cpusets only.

Patch 9 enables the forced turnning off of partition flag if changes made to "cpuset.cpus" makes a partition root cpuset not qualified to be a partition root anymore. Forced clearing of the partition flag, though allowed, is not recommended and a warning will be printed.

With the addition of forced turning off of partition flag, any changes made to the "cpuset.cpus" allowable on a non-partition root cpuset can be made to a parition root with the exception that the implied cpu_exclusive nature of a partition root will forbid adding cpus that have been allocated to its siblings.

Waiman Long (9):
cpuset: Enable cpuset controller in default hierarchy
cpuset: Add new v2 cpuset.sched.partition flag
cpuset: Simulate auto-off of sched.partition at cgroup removal
cpuset: Allow changes to cpus in a partition root
cpuset: Make sure that partition flag work properly with CPU hotplug
cpuset: Make generate_sched_domains() recognize reserved_cpus
cpuset: Expose cpus.effective and mems.effective on cgroup v2 root
cpuset: Don't rebuild sched domains if cpu changes in non-partition
root
cpuset: Support forced turning off of partition flag

 Documentation/admin-guide/cgroup-v2.rst | 174 ++++++++++++-
 kernel/cgroup/cpuset.c                  | 441 ++++++++++++++++++++++++++++++--
 2 files changed, 593 insertions(+), 22 deletions(-)
Signature · 1 line
1.8.3.1
author maintainer
#1 lore raw

PATCH v12 1/9 cpuset: Enable cpuset controller in default hierarchy

Given the fact that thread mode had been merged into 4.14, it is now time to enable cpuset to be used in the default hierarchy (cgroup v2) as it is clearly threaded.

The cpuset controller had experienced feature creep since its introduction more than a decade ago. Besides the core cpus and mems control files to limit cpus and memory nodes, there are a bunch of additional features that can be controlled from the userspace. Some of the features are of doubtful usefulness and may not be actively used.

This patch enables cpuset controller in the default hierarchy with a minimal set of features, namely just the cpus and mems and their effective_* counterparts. We can certainly add more features to the default hierarchy in the future if there is a real user need for them later on.

Alternatively, with the unified hiearachy, it may make more sense to move some of those additional cpuset features, if desired, to memory controller or may be to the cpu controller instead of staying with cpuset.

---
 Documentation/admin-guide/cgroup-v2.rst | 109 ++++++++++++++++++++++++++++++--
 kernel/cgroup/cpuset.c                  |  48 +++++++++++++-
 2 files changed, 149 insertions(+), 8 deletions(-)
Documentation/admin-guide/cgroup-v2.rst +104 -5
index 1746131..a09b7f7 100644
@@ -56,11 +56,13 @@ v1 is available under Documentation/cgroup-v1/.
          5-3-3-2. IO Latency Interface Files
      5-4. PID
        5-4-1. PID Interface Files
-     5-5. Device
-     5-6. RDMA
-       5-6-1. RDMA Interface Files
-     5-7. Misc
-       5-7-1. perf_event
+     5-5. Cpuset
+       5.5-1. Cpuset Interface Files
+     5-6. Device
+     5-7. RDMA
+       5-7-1. RDMA Interface Files
+     5-8. Misc
+       5-8-1. perf_event
      5-N. Non-normative information
        5-N-1. CPU controller root cgroup process behaviour
        5-N-2. IO controller root cgroup process behaviour
@@ -1570,6 +1572,103 @@ through fork() or clone(). These will return -EAGAIN if the creation
 of a new process would cause a cgroup policy to be violated.
 
 
+Cpuset
+------
+
+The "cpuset" controller provides a mechanism for constraining
+the CPU and memory node placement of tasks to only the resources
+specified in the cpuset interface files in a task's current cgroup.
+This is especially valuable on large NUMA systems where placing jobs
+on properly sized subsets of the systems with careful processor and
+memory placement to reduce cross-node memory access and contention
+can improve overall system performance.
+
+The "cpuset" controller is hierarchical.  That means the controller
+cannot use CPUs or memory nodes not allowed in its parent.
+
+
+Cpuset Interface Files
+~~~~~~~~~~~~~~~~~~~~~~
+
+  cpuset.cpus
+	A read-write multiple values file which exists on non-root
+	cpuset-enabled cgroups.
+
+	It lists the requested CPUs to be used by tasks within this
+	cgroup.  The actual list of CPUs to be granted, however, is
+	subjected to constraints imposed by its parent and can differ
+	from the requested CPUs.
+
+	The CPU numbers are comma-separated numbers or ranges.
+	For example:
+
+	  # cat cpuset.cpus
+	  0-4,6,8-10
+
+	An empty value indicates that the cgroup is using the same
+	setting as the nearest cgroup ancestor with a non-empty
+	"cpuset.cpus" or all the available CPUs if none is found.
+
+	The value of "cpuset.cpus" stays constant until the next update
+	and won't be affected by any CPU hotplug events.
+
+  cpuset.cpus.effective
+	A read-only multiple values file which exists on non-root
+	cpuset-enabled cgroups.
+
+	It lists the onlined CPUs that are actually granted to this
+	cgroup by its parent.  These CPUs are allowed to be used by
+	tasks within the current cgroup.
+
+	If "cpuset.cpus" is empty, the "cpuset.cpus.effective" file shows
+	all the CPUs from the parent cgroup that can be available to
+	be used by this cgroup.  Otherwise, it should be a subset of
+	"cpuset.cpus" unless none of the CPUs listed in "cpuset.cpus"
+	can be granted.  In this case, it will be treated just like an
+	empty "cpuset.cpus".
+
+	Its value will be affected by CPU hotplug events.
+
+  cpuset.mems
+	A read-write multiple values file which exists on non-root
+	cpuset-enabled cgroups.
+
+	It lists the requested memory nodes to be used by tasks within
+	this cgroup.  The actual list of memory nodes granted, however,
+	is subjected to constraints imposed by its parent and can differ
+	from the requested memory nodes.
+
+	The memory node numbers are comma-separated numbers or ranges.
+	For example:
+
+	  # cat cpuset.mems
+	  0-1,3
+
+	An empty value indicates that the cgroup is using the same
+	setting as the nearest cgroup ancestor with a non-empty
+	"cpuset.mems" or all the available memory nodes if none
+	is found.
+
+	The value of "cpuset.mems" stays constant until the next update
+	and won't be affected by any memory nodes hotplug events.
+
+  cpuset.mems.effective
+	A read-only multiple values file which exists on non-root
+	cpuset-enabled cgroups.
+
+	It lists the onlined memory nodes that are actually granted to
+	this cgroup by its parent. These memory nodes are allowed to
+	be used by tasks within the current cgroup.
+
+	If "cpuset.mems" is empty, it shows all the memory nodes from the
+	parent cgroup that will be available to be used by this cgroup.
+	Otherwise, it should be a subset of "cpuset.mems" unless none of
+	the memory nodes listed in "cpuset.mems" can be granted.  In this
+	case, it will be treated just like an empty "cpuset.mems".
+
+	Its value will be affected by memory nodes hotplug events.
+
+
 Device controller
 -----------------
 
kernel/cgroup/cpuset.c +45 -3

71 lines not on this page · raw message

Signature · 1 line
1.8.3.1
author maintainer
#2 lore raw

PATCH v12 2/9 cpuset: Add new v2 cpuset.sched.partition flag

In reply to Waiman Long

A new cpuset.sched.partition boolean flag is added to cpuset v2. This new flag, if set, indicates that the cgroup is the root of a new scheduling domain or partition that includes itself and all its descendants except those that are scheduling domain roots themselves and their descendants.

With this new flag, one can directly create as many partitions as necessary without ever using the v1 trick of turning off load balancing in specific cpusets to create partitions as a side effect.

This new flag is owned by the parent and will cause the CPUs in the cpuset to be removed from the effective CPUs of its parent.

This is implemented internally by adding a new reserved_cpus mask that holds the CPUs belonging to child scheduling domain cpusets so that:

reserved_cpus | effective_cpus = cpus_allowed reserved_cpus & effective_cpus = 0

This new flag can only be turned on in a cpuset if its parent is a partition root itself. The state of this flag cannot be changed if the cpuset has children.

---
 Documentation/admin-guide/cgroup-v2.rst |  33 ++++++
 kernel/cgroup/cpuset.c                  | 184 +++++++++++++++++++++++++++++++-
 2 files changed, 214 insertions(+), 3 deletions(-)
Documentation/admin-guide/cgroup-v2.rst +33 -0
index a09b7f7..5e33d25 100644
@@ -1668,6 +1668,39 @@ Cpuset Interface Files
 
 	Its value will be affected by memory nodes hotplug events.
 
+  cpuset.sched.partition
+	A read-write single value file which exists on non-root
+	cpuset-enabled cgroups.  It is a binary value flag that accepts
+	either "0" (off) or "1" (on).  This flag is set and owned by the
+        parent cgroup.
+
+	If set, it indicates that the current cgroup is the root of a
+	new partition or scheduling domain that comprises itself and
+	all its descendants except those that are separate partition
+        roots themselves and their descendants.  The root cgroup is
+	always a partition root.
+
+	There are constraints on where this flag can be set.  It can
+	only be set in a cgroup if all the following conditions are true.
+
+	1) The "cpuset.cpus" is not empty and the list of CPUs are
+	   exclusive, i.e. they are not shared by any of its siblings.
+	2) The "cpuset.cpus" is also a proper subset of the parent's
+	   "cpuset.cpus.effective".
+	3) The parent cgroup is a partition root.
+	4) There is no child cgroups with cpuset enabled.  This is for
+	   eliminating corner cases that have to be handled if such a
+	   condition is allowed.
+
+	Setting this flag will take the CPUs away from the effective
+	CPUs of the parent cgroup.  That is why this flag has to be set
+	and owned by the parent.  Once it is set, this flag cannot be
+	cleared if there are any child cgroups with cpuset enabled.
+
+	A parent partition root cgroup cannot distribute all its CPUs to
+        its child partition root cgroups.  There must be at least one cpu
+        left in the parent partition root cgroup.
+
 
 Device controller
 -----------------
kernel/cgroup/cpuset.c +181 -3

284 lines not on this page · raw message

Signature · 1 line
1.8.3.1
author maintainer
#3 lore raw

PATCH v12 3/9 cpuset: Simulate auto-off of sched.partition at cgroup removal

In reply to Waiman Long

Making a cgroup a partition root will reserve cpu resource at its parent. So when a partition root cgroup is destroyed, we need to free the reserved cpus at its parent. This is now done by doing an auto-off of the sched.partition flag in the offlining phase when a partition root cgroup is being removed.

---
 kernel/cgroup/cpuset.c | 20 ++++++++++++++++++--
 1 file changed, 18 insertions(+), 2 deletions(-)
kernel/cgroup/cpuset.c +18 -2
index fdaa051..d9e821c 100644
@@ -2253,7 +2253,12 @@ static int cpuset_css_online(struct cgroup_subsys_state *css)
 /*
  * If the cpuset being removed has its flag 'sched_load_balance'
  * enabled, then simulate turning sched_load_balance off, which
- * will call rebuild_sched_domains_locked().
+ * will call rebuild_sched_domains_locked(). That is not needed
+ * in the default hierarchy where only changes in partition
+ * will cause repartitioning.
+ *
+ * If the cpuset has the 'sched.partition' flag enabled, simulate
+ * turning 'sched.partition" off.
  */
 
 static void cpuset_css_offline(struct cgroup_subsys_state *css)
@@ -2262,7 +2267,18 @@ static void cpuset_css_offline(struct cgroup_subsys_state *css)
 
 	mutex_lock(&cpuset_mutex);
 
-	if (is_sched_load_balance(cs))
+	/*
+	 * A WARN_ON_ONCE() check after calling update_flag() to make
+	 * sure that the operation succceeds without failure.
+	 */
+	if (is_partition_root(cs)) {
+		int ret = update_flag(CS_PARTITION_ROOT, cs, 0);
+
+		WARN_ON_ONCE(ret);
+	}
+
+	if (!cgroup_subsys_on_dfl(cpuset_cgrp_subsys) &&
+	    is_sched_load_balance(cs))
 		update_flag(CS_SCHED_LOAD_BALANCE, cs, 0);
 
 	cpuset_dec();
Signature · 1 line
1.8.3.1
author maintainer
#4 lore raw

PATCH v12 4/9 cpuset: Allow changes to cpus in a partition root

In reply to Waiman Long

The previous patch introduces a new partition flag, but won't allow changes made to "cpuset.cpus" once the flag is on. That may be too restrictive in some use cases. So this restiction is now relaxed to allow changes made to the "cpuset.cpus" file with some constraints:

1) The new set of cpus must still be exclusive.
2) Newly added cpus must be a subset of the parent effective_cpus.
3) None of the deleted cpus can be one of those allocated to a child partition roots, if present.

---
 Documentation/admin-guide/cgroup-v2.rst |  9 +++++
 kernel/cgroup/cpuset.c                  | 61 ++++++++++++++++++++++++++-------
 2 files changed, 58 insertions(+), 12 deletions(-)
Documentation/admin-guide/cgroup-v2.rst +9 -0
index 5e33d25..a5fc335 100644
@@ -1701,6 +1701,15 @@ Cpuset Interface Files
         its child partition root cgroups.  There must be at least one cpu
         left in the parent partition root cgroup.
 
+	In a partition root, changes to "cpuset.cpus" is allowed as long
+	as the first condition above as well as the following two
+	additional conditions are true.
+
+	1) Any added CPUs must be a proper subset of the parent's
+	   "cpuset.cpus.effective".
+	2) No CPU that has been distributed to child partition roots is
+	   is deleted.
+
 
 Device controller
 -----------------
kernel/cgroup/cpuset.c +49 -12

135 lines not on this page · raw message

Signature · 1 line
1.8.3.1
author maintainer
#5 lore raw

PATCH v12 5/9 cpuset: Make sure that partition flag work properly with CPU hotplug

In reply to Waiman Long

When there is a cpu hotplug event (CPU online or offline), the partitions may need to be reconfigured and regenerated. So code is added to the hotplug functions to make them work with new reserved_cpus mask to compute the right effective_cpus for each of the affected cpusets.

---
 Documentation/admin-guide/cgroup-v2.rst | 10 ++++++++++
 kernel/cgroup/cpuset.c                  | 26 ++++++++++++++++++++++++--
 2 files changed, 34 insertions(+), 2 deletions(-)
Documentation/admin-guide/cgroup-v2.rst +10 -0
index a5fc335..234fb18 100644
@@ -1710,6 +1710,16 @@ Cpuset Interface Files
 	2) No CPU that has been distributed to child partition roots is
 	   is deleted.
 
+	When all the CPUs allocated to a partition are offlined, the
+	partition will be temporaily gone and all the tasks in it will
+	be migrated to another one that belongs to the parent of the
+	partition root.  This is a destructive operation and all the
+	existing CPU affinity that is narrower than the cpuset itself
+	will be lost.
+
+	When any of those offlined CPUs is onlined again, a new partition
+	will be re-created and the tasks will be migrated back.
+
 
 Device controller
 -----------------
kernel/cgroup/cpuset.c +24 -2
index 56e0931..5b1e64d 100644
@@ -900,7 +900,8 @@ static void update_tasks_cpumask(struct cpuset *cs)
  * @parent: the parent cpuset
  *
  * If the parent has reserved CPUs, include them in the list of allowable
- * CPUs in computing the new effective_cpus mask.
+ * CPUs in computing the new effective_cpus mask. The cpu_active_mask is
+ * used to mask off cpus that are to be offlined.
  */
 static void compute_effective_cpumask(struct cpumask *new_cpus,
 				      struct cpuset *cs, struct cpuset *parent)
@@ -909,6 +910,7 @@ static void compute_effective_cpumask(struct cpumask *new_cpus,
 		cpumask_or(new_cpus, parent->effective_cpus,
 			   parent->reserved_cpus);
 		cpumask_and(new_cpus, new_cpus, cs->cpus_allowed);
+		cpumask_and(new_cpus, new_cpus, cpu_active_mask);
 	} else {
 		cpumask_and(new_cpus, cs->cpus_allowed, parent->effective_cpus);
 	}
@@ -2528,9 +2530,17 @@ static void cpuset_hotplug_update_tasks(struct cpuset *cs)
 		goto retry;
 	}
 
-	cpumask_and(&new_cpus, cs->cpus_allowed, parent_cs(cs)->effective_cpus);
+	compute_effective_cpumask(&new_cpus, cs, parent_cs(cs));
 	nodes_and(new_mems, cs->mems_allowed, parent_cs(cs)->effective_mems);
 
+	if (cs->nr_reserved) {
+		/*
+		 * Some of the CPUs may have been distributed to child
+		 * partition roots. So we need skip those when computing the
+		 * real effective cpus.
+		 */
+		cpumask_andnot(&new_cpus, &new_cpus, cs->reserved_cpus);
+	}
 	cpus_updated = !cpumask_equal(&new_cpus, cs->effective_cpus);
 	mems_updated = !nodes_equal(new_mems, cs->effective_mems);
 
@@ -2580,6 +2590,11 @@ static void cpuset_hotplug_workfn(struct work_struct *work)
 	cpumask_copy(&new_cpus, cpu_active_mask);
 	new_mems = node_states[N_MEMORY];
 
+	/*
+	 * If reserved_cpus is populated, it is likely that the check below
+	 * will produce a false positive on cpus_updated when the cpu list
+	 * isn't changed. It is extra work, but it is better to be safe.
+	 */
 	cpus_updated = !cpumask_equal(top_cpuset.effective_cpus, &new_cpus);
 	mems_updated = !nodes_equal(top_cpuset.effective_mems, new_mems);
 
@@ -2588,6 +2603,13 @@ static void cpuset_hotplug_workfn(struct work_struct *work)
 		spin_lock_irq(&callback_lock);
 		if (!on_dfl)
 			cpumask_copy(top_cpuset.cpus_allowed, &new_cpus);
+		/*
+		 * Make sure that the reserved cpus aren't in the
+		 * effective cpus.
+		 */
+		if (top_cpuset.nr_reserved)
+			cpumask_andnot(&new_cpus, &new_cpus,
+					top_cpuset.reserved_cpus);
 		cpumask_copy(top_cpuset.effective_cpus, &new_cpus);
 		spin_unlock_irq(&callback_lock);
 		/* we don't mess with cpumasks of tasks in top_cpuset */
Signature · 1 line
1.8.3.1
author maintainer
#6 lore raw

PATCH v12 6/9 cpuset: Make generate_sched_domains() recognize reserved_cpus

In reply to Waiman Long

The generate_sched_domains() function is modified to make it work correctly with the newly introduced reserved_cpus mask for schedule domains generation.

---
 kernel/cgroup/cpuset.c | 24 ++++++++++++++++++++----
 1 file changed, 20 insertions(+), 4 deletions(-)
kernel/cgroup/cpuset.c +20 -4
index 5b1e64d..286b851 100644
@@ -672,13 +672,14 @@ static int generate_sched_domains(cpumask_var_t **domains,
 	int ndoms = 0;		/* number of sched domains in result */
 	int nslot;		/* next empty doms[] struct cpumask slot */
 	struct cgroup_subsys_state *pos_css;
+	bool root_load_balance = is_sched_load_balance(&top_cpuset);
 
 	doms = NULL;
 	dattr = NULL;
 	csa = NULL;
 
 	/* Special case for the 99% of systems with one, full, sched domain */
-	if (is_sched_load_balance(&top_cpuset)) {
+	if (root_load_balance && !top_cpuset.nr_reserved) {
 		ndoms = 1;
 		doms = alloc_sched_domains(ndoms);
 		if (!doms)
@@ -701,6 +702,8 @@ static int generate_sched_domains(cpumask_var_t **domains,
 	csn = 0;
 
 	rcu_read_lock();
+	if (root_load_balance)
+		csa[csn++] = &top_cpuset;
 	cpuset_for_each_descendant_pre(cp, pos_css, &top_cpuset) {
 		if (cp == &top_cpuset)
 			continue;
@@ -711,6 +714,9 @@ static int generate_sched_domains(cpumask_var_t **domains,
 		 * parent's cpus, so just skip them, and then we call
 		 * update_domain_attr_tree() to calc relax_domain_level of
 		 * the corresponding sched domain.
+		 *
+		 * If root is load-balancing, we can skip @cp if it
+		 * is a subset of the root's effective_cpus.
 		 */
 		if (!cpumask_empty(cp->cpus_allowed) &&
 		    !(is_sched_load_balance(cp) &&
@@ -718,11 +724,16 @@ static int generate_sched_domains(cpumask_var_t **domains,
 					 housekeeping_cpumask(HK_FLAG_DOMAIN))))
 			continue;
 
+		if (root_load_balance &&
+		    cpumask_subset(cp->cpus_allowed, top_cpuset.effective_cpus))
+			continue;
+
 		if (is_sched_load_balance(cp))
 			csa[csn++] = cp;
 
-		/* skip @cp's subtree */
-		pos_css = css_rightmost_descendant(pos_css);
+		/* skip @cp's subtree if not a partition root */
+		if (!is_partition_root(cp))
+			pos_css = css_rightmost_descendant(pos_css);
 	}
 	rcu_read_unlock();
 
@@ -850,7 +861,12 @@ static void rebuild_sched_domains_locked(void)
 	 * passing doms with offlined cpu to partition_sched_domains().
 	 * Anyways, hotplug work item will rebuild sched domains.
 	 */
-	if (!cpumask_equal(top_cpuset.effective_cpus, cpu_active_mask))
+	if (!top_cpuset.nr_reserved &&
+	    !cpumask_equal(top_cpuset.effective_cpus, cpu_active_mask))
+		goto out;
+
+	if (top_cpuset.nr_reserved &&
+	   !cpumask_subset(top_cpuset.effective_cpus, cpu_active_mask))
 		goto out;
 
 	/* Generate domain masks and attrs */
Signature · 1 line
1.8.3.1
author maintainer
#7 lore raw

PATCH v12 7/9 cpuset: Expose cpus.effective and mems.effective on cgroup v2 root

In reply to Waiman Long

Because of the fact that setting the "cpuset.sched.partition" in a direct child of root can remove CPUs from the root's effective CPU list, it makes sense to know what CPUs are left in the root cgroup for scheduling purpose. So the "cpuset.cpus.effective" control file is now exposed in the v2 cgroup root.

For consistency, the "cpuset.mems.effective" control file is exposed as well.

---
 Documentation/admin-guide/cgroup-v2.rst | 4 ++--
 kernel/cgroup/cpuset.c                  | 2 --
 2 files changed, 2 insertions(+), 4 deletions(-)
Documentation/admin-guide/cgroup-v2.rst +2 -2
index 234fb18..655e54e 100644
@@ -1613,7 +1613,7 @@ Cpuset Interface Files
 	and won't be affected by any CPU hotplug events.
 
   cpuset.cpus.effective
-	A read-only multiple values file which exists on non-root
+	A read-only multiple values file which exists on all
 	cpuset-enabled cgroups.
 
 	It lists the onlined CPUs that are actually granted to this
@@ -1653,7 +1653,7 @@ Cpuset Interface Files
 	and won't be affected by any memory nodes hotplug events.
 
   cpuset.mems.effective
-	A read-only multiple values file which exists on non-root
+	A read-only multiple values file which exists on all
 	cpuset-enabled cgroups.
 
 	It lists the onlined memory nodes that are actually granted to
kernel/cgroup/cpuset.c +0 -2
index 286b851..0e41b62 100644
@@ -2182,14 +2182,12 @@ static s64 cpuset_read_s64(struct cgroup_subsys_state *css, struct cftype *cft)
 		.name = "cpus.effective",
 		.seq_show = cpuset_common_seq_show,
 		.private = FILE_EFFECTIVE_CPULIST,
-		.flags = CFTYPE_NOT_ON_ROOT,
 	},
 
 	{
 		.name = "mems.effective",
 		.seq_show = cpuset_common_seq_show,
 		.private = FILE_EFFECTIVE_MEMLIST,
-		.flags = CFTYPE_NOT_ON_ROOT,
 	},
 
 	{
Signature · 1 line
1.8.3.1
author maintainer
#8 lore raw

PATCH v12 8/9 cpuset: Don't rebuild sched domains if cpu changes in non-partition root

In reply to Waiman Long

With the cpuset v1, any changes to the list of allowable CPUs in a cpuset may cause changes in the sched domain configuration depending on the load balancing states and the cpu lists of its parent and its children.

With cpuset v2 (on default hierarchy), there are more restrictions on how the load balancing state of a cpuset can change. As a result, only changes made in a partition root will cause possible changes to the corresponding sched domain. CPU changes to any of the non-partition root cpusets will not cause changes in the sched domain configuration. As a result, we don't need to call rebuild_sched_domains_locked() for changes in a non-partition root cpuset saving precious cpu cycles.

---
 kernel/cgroup/cpuset.c | 10 +++++++---
 1 file changed, 7 insertions(+), 3 deletions(-)
kernel/cgroup/cpuset.c +7 -3
index 0e41b62..d8970b4 100644
@@ -986,11 +986,15 @@ static void update_cpumasks_hier(struct cpuset *cs, struct cpumask *new_cpus)
 		update_tasks_cpumask(cp);
 
 		/*
-		 * If the effective cpumask of any non-empty cpuset is changed,
-		 * we need to rebuild sched domains.
+		 * On legacy hierarchy, if the effective cpumask of any non-
+		 * empty cpuset is changed, we need to rebuild sched domains.
+		 * On default hierarchy, the cpuset needs to be a partition
+		 * root as well.
 		 */
 		if (!cpumask_empty(cp->cpus_allowed) &&
-		    is_sched_load_balance(cp))
+		    is_sched_load_balance(cp) &&
+		   (!cgroup_subsys_on_dfl(cpuset_cgrp_subsys) ||
+		    is_partition_root(cp)))
 			need_rebuild_sched_domains = true;
 
 		rcu_read_lock();
Signature · 1 line
1.8.3.1
author maintainer
#9 lore raw

PATCH v12 9/9 cpuset: Support forced turning off of partition flag

In reply to Waiman Long

Cpuset allows arbitrary modification of cpu list in "cpuset.cpus" even if the requested CPUs won't be granted in "cpuset.cpus.effective" as restricted by its parent. However, the validate_change() function will inhibit removal of CPUs that have been used in child cpusets.

Being a partition root, however, limits the kind of cpu list modification that is allowed. Adding CPUs is not allowed if the new CPUs are not in the parent's effective cpu list that can be put into "cpuset.cpus.reserved". In addition, a child partition cannot exhaust all the parent's effective CPUs.

Because of the implicit cpu exclusive nature of the partition root, cpu changes that break that cpu exclusivity will not be allowed. Other changes that break the conditions of being a partition root is generally allowed. However, the partition flag of the cpuset as well those of the descendant partitions will be forcefully turned off.

Removing CPUs from a partition root is generally allowed as long as there is at least one CPU left with no conflicts with child cpusets, if present. If all the CPUs are removed, the partition flag will be forced off as well.

The partition flag clearing code is being extracted out from update_reserved_cpumask() into a new clear_partition_flag() function so that the new code can be called recursively in the case of forced turning off with minimal stack footprint.

Sched domains have to be rebuilt whenever a forced turning off of the partition flag happens.

---
 Documentation/admin-guide/cgroup-v2.rst |  45 +++++++----
 kernel/cgroup/cpuset.c                  | 136 +++++++++++++++++++++++++++-----
 2 files changed, 144 insertions(+), 37 deletions(-)
Documentation/admin-guide/cgroup-v2.rst +29 -16
index 655e54e..1f63ccf 100644
@@ -1695,27 +1695,40 @@ Cpuset Interface Files
 	Setting this flag will take the CPUs away from the effective
 	CPUs of the parent cgroup.  That is why this flag has to be set
 	and owned by the parent.  Once it is set, this flag cannot be
-	cleared if there are any child cgroups with cpuset enabled.
+	explicitly cleared if there are any child cgroups with cpuset
+	enabled.
 
 	A parent partition root cgroup cannot distribute all its CPUs to
         its child partition root cgroups.  There must be at least one cpu
         left in the parent partition root cgroup.
 
-	In a partition root, changes to "cpuset.cpus" is allowed as long
-	as the first condition above as well as the following two
-	additional conditions are true.
-
-	1) Any added CPUs must be a proper subset of the parent's
-	   "cpuset.cpus.effective".
-	2) No CPU that has been distributed to child partition roots is
-	   is deleted.
-
-	When all the CPUs allocated to a partition are offlined, the
-	partition will be temporaily gone and all the tasks in it will
-	be migrated to another one that belongs to the parent of the
-	partition root.  This is a destructive operation and all the
-	existing CPU affinity that is narrower than the cpuset itself
-	will be lost.
+	In a partition root, removing CPUs from "cpuset.cpus" is allowed
+	as long as none of the removed CPUs are used by any of the
+	child cpusets, if defined.  However, if the CPU removal cause
+	its effective CPU list to become empty, the kernel will have
+	no choice but to forcefully turn off the partition flag of the
+	current cpuset as well as any descendant partitions underneath it.
+	This is a destructive operation and the partition states will
+	not be restored even when the CPUs are added back later on.
+
+	Adding CPUs to "cpuset.cpus" of a partition root is generally
+	allowed.  Because of the cpu exclusivity nature of a partition
+	root, CPU changes that break the cpu exclusivity will not be
+	permitted.  For other CPU changes that break either one of the
+	first three conditions of being a partition root listed above,
+	it will cause the same forced turning off of the partition flag
+	as discussed before.
+
+	The act of forcefully clearing the partition flag by making
+	changes to "cpuset.cpus" is generally not recommended.	A warning
+	message will be printed when that happens.
+
+	CPU offlining is handled differently as it won't cause a forced
+	turning off the partition flag. When all the CPUs allocated to
+	a partition are offlined, the partition will be temporaily gone
+	and all the tasks in it will be migrated to the parent partition.
+	This is a destructive operation and all the existing CPU affinity
+	that is narrower than the cpuset itself will be lost.
 
 	When any of those offlined CPUs is onlined again, a new partition
 	will be re-created and the tasks will be migrated back.
kernel/cgroup/cpuset.c +115 -21

198 lines not on this page · raw message

Signature · 1 line
1.8.3.1
maintainer
#10 lore raw

Re: [PATCH v12 9/9] cpuset: Support forced turning off of partition flag

Hello, Waiman.

Quoted 11 lines · Waiman Long

Cpuset allows arbitrary modification of cpu list in "cpuset.cpus" even if the requested CPUs won't be granted in "cpuset.cpus.effective" as restricted by its parent. However, the validate_change() function will inhibit removal of CPUs that have been used in child cpusets.

Being a partition root, however, limits the kind of cpu list modification that is allowed. Adding CPUs is not allowed if the new CPUs are not in the parent's effective cpu list that can be put into "cpuset.cpus.reserved". In addition, a child partition cannot exhaust all the parent's effective CPUs.

Quoted 5 lines

Because of the implicit cpu exclusive nature of the partition root, cpu changes that break that cpu exclusivity will not be allowed. Other changes that break the conditions of being a partition root is generally allowed. However, the partition flag of the cpuset as well those of the descendant partitions will be forcefully turned off.

First of all, thanks a lot for your persistence. I'm not necessarily against the flag being forced off but wonder whether the same config/effective approach can be used as in .cpus and .mems. Can you elaborate a bit on the choice here?

Thank you.

Signature · 1 line
tejun
author maintainer
#11 lore raw

Re: [PATCH v12 9/9] cpuset: Support forced turning off of partition flag

Quoted 19 lines · Tejun Heo

Hello, Waiman.

Quoted 11 lines · Waiman Long

Cpuset allows arbitrary modification of cpu list in "cpuset.cpus" even if the requested CPUs won't be granted in "cpuset.cpus.effective" as restricted by its parent. However, the validate_change() function will inhibit removal of CPUs that have been used in child cpusets.

Being a partition root, however, limits the kind of cpu list modification that is allowed. Adding CPUs is not allowed if the new CPUs are not in the parent's effective cpu list that can be put into "cpuset.cpus.reserved". In addition, a child partition cannot exhaust all the parent's effective CPUs.

Quoted 5 lines

Because of the implicit cpu exclusive nature of the partition root, cpu changes that break that cpu exclusivity will not be allowed. Other changes that break the conditions of being a partition root is generally allowed. However, the partition flag of the cpuset as well those of the descendant partitions will be forcefully turned off.

Quoted 6 lines

First of all, thanks a lot for your persistence. I'm not necessarily against the flag being forced off but wonder whether the same config/effective approach can be used as in .cpus and .mems. Can you elaborate a bit on the choice here?

Thank you.

My current code has explicitly assumed the following relationship for partition root.

cpus_allowed = effective_cpus + reserved_cpus

Also effective_cpus cannot be empty. Specifically, cpus_allowed has to be equal to effective_cpus before a cpuset can be made a partition root.

Any changes that break the above conditions will turn off the partition flag forcefully. The only exception is cpu offlining where cpus_allowed

Quoted 1 line

effective_cpus + reserved_cpus can happen.

One reason for doing so is because reserved_cpus is hidden. So the main way to infer that is to do cpus_allowed - effective_cpus.

It is probably doable to make cpus_allowed >= effective_cpus + reserved_cpus in general, but we may need to expose reserved_cpus as a read-only file, for instance. There may also be other complications that we will need to take care of if this is supported. My current preference is to not doing that unless there is compelling reason to do so.

Cheers,
Longman

author maintainer
#12 lore raw

Re: [PATCH v12 9/9] cpuset: Support forced turning off of partition flag

Quoted 40 lines · Waiman Long
Quoted 19 lines · Tejun Heo

Hello, Waiman.

Quoted 11 lines · Waiman Long

Cpuset allows arbitrary modification of cpu list in "cpuset.cpus" even if the requested CPUs won't be granted in "cpuset.cpus.effective" as restricted by its parent. However, the validate_change() function will inhibit removal of CPUs that have been used in child cpusets.

Being a partition root, however, limits the kind of cpu list modification that is allowed. Adding CPUs is not allowed if the new CPUs are not in the parent's effective cpu list that can be put into "cpuset.cpus.reserved". In addition, a child partition cannot exhaust all the parent's effective CPUs.

Quoted 5 lines

Because of the implicit cpu exclusive nature of the partition root, cpu changes that break that cpu exclusivity will not be allowed. Other changes that break the conditions of being a partition root is generally allowed. However, the partition flag of the cpuset as well those of the descendant partitions will be forcefully turned off.

Quoted 6 lines

First of all, thanks a lot for your persistence. I'm not necessarily against the flag being forced off but wonder whether the same config/effective approach can be used as in .cpus and .mems. Can you elaborate a bit on the choice here?

Thank you.

My current code has explicitly assumed the following relationship for partition root.

cpus_allowed = effective_cpus + reserved_cpus

Also effective_cpus cannot be empty. Specifically, cpus_allowed has to be equal to effective_cpus before a cpuset can be made a partition root.

Any changes that break the above conditions will turn off the partition flag forcefully. The only exception is cpu offlining where cpus_allowed

Quoted 1 line

effective_cpus + reserved_cpus can happen.

One reason for doing so is because reserved_cpus is hidden. So the main way to infer that is to do cpus_allowed - effective_cpus.

Quoted 8 lines

It is probably doable to make cpus_allowed >= effective_cpus + reserved_cpus in general, but we may need to expose reserved_cpus as a read-only file, for instance. There may also be other complications that we will need to take care of if this is supported. My current preference is to not doing that unless there is compelling reason to do so.

Cheers,
Longman

For the current patch, one of conditions to allow users to turn on the partition flag is cpus_allowed = effective_cpus. Once the partition flag is on, the twos have to be the same too except with cpu offlining. This patch is added to allow arbitrary modification to the cpuset.cpus file except those that have already been forbidden in the existing code. When the modification violates the rules of being a partition root, the flag will be turned off or we will have to deny the modification request.

I am admitting that it is an easy way out in term of programming effort as I am not sure how much effort is needed to enable arbitrary modification to cpuset.cpus without force disabling and whether such an effort is even worthwhile to do.

We can certainly relax the current restrictions in the future. Any suggestion to improve the patchset is welcome. I would really like to see this merged in 4.20 (or maybe 5.0) kernel.

Cheers,
Longman

author maintainer
#13 lore raw

Re: [PATCH v12 9/9] cpuset: Support forced turning off of partition flag

Quoted 62 lines · Waiman Long
Quoted 40 lines · Waiman Long
Quoted 19 lines · Tejun Heo

Hello, Waiman.

Quoted 11 lines · Waiman Long

Cpuset allows arbitrary modification of cpu list in "cpuset.cpus" even if the requested CPUs won't be granted in "cpuset.cpus.effective" as restricted by its parent. However, the validate_change() function will inhibit removal of CPUs that have been used in child cpusets.

Being a partition root, however, limits the kind of cpu list modification that is allowed. Adding CPUs is not allowed if the new CPUs are not in the parent's effective cpu list that can be put into "cpuset.cpus.reserved". In addition, a child partition cannot exhaust all the parent's effective CPUs.

Quoted 5 lines

Because of the implicit cpu exclusive nature of the partition root, cpu changes that break that cpu exclusivity will not be allowed. Other changes that break the conditions of being a partition root is generally allowed. However, the partition flag of the cpuset as well those of the descendant partitions will be forcefully turned off.

Quoted 6 lines

First of all, thanks a lot for your persistence. I'm not necessarily against the flag being forced off but wonder whether the same config/effective approach can be used as in .cpus and .mems. Can you elaborate a bit on the choice here?

Thank you.

My current code has explicitly assumed the following relationship for partition root.

cpus_allowed = effective_cpus + reserved_cpus

Also effective_cpus cannot be empty. Specifically, cpus_allowed has to be equal to effective_cpus before a cpuset can be made a partition root.

Any changes that break the above conditions will turn off the partition flag forcefully. The only exception is cpu offlining where cpus_allowed

Quoted 1 line

effective_cpus + reserved_cpus can happen.

One reason for doing so is because reserved_cpus is hidden. So the main way to infer that is to do cpus_allowed - effective_cpus.

Quoted 8 lines

It is probably doable to make cpus_allowed >= effective_cpus + reserved_cpus in general, but we may need to expose reserved_cpus as a read-only file, for instance. There may also be other complications that we will need to take care of if this is supported. My current preference is to not doing that unless there is compelling reason to do so.

Cheers,
Longman

For the current patch, one of conditions to allow users to turn on the partition flag is cpus_allowed = effective_cpus. Once the partition flag is on, the twos have to be the same too except with cpu offlining. This patch is added to allow arbitrary modification to the cpuset.cpus file except those that have already been forbidden in the existing code. When the modification violates the rules of being a partition root, the flag will be turned off or we will have to deny the modification request.

I am admitting that it is an easy way out in term of programming effort as I am not sure how much effort is needed to enable arbitrary modification to cpuset.cpus without force disabling and whether such an effort is even worthwhile to do.

Quoted 7 lines

We can certainly relax the current restrictions in the future. Any suggestion to improve the patchset is welcome. I would really like to see this merged in 4.20 (or maybe 5.0) kernel.

Cheers,
Longman

Tejun,

Sorry for bothering you again.

I would like to know your assessment of this patchset as to whether it is ready or not.

Thanks,
Longman

maintainer
#14 lore raw

Re: [PATCH v12 9/9] cpuset: Support forced turning off of partition flag

In reply to Waiman Long

Hello, Waiman.

My apologies for the delay.

Quoted 12 lines · Waiman Long

My current code has explicitly assumed the following relationship for partition root.

cpus_allowed = effective_cpus + reserved_cpus

Also effective_cpus cannot be empty. Specifically, cpus_allowed has to be equal to effective_cpus before a cpuset can be made a partition root.

Any changes that break the above conditions will turn off the partition flag forcefully. The only exception is cpu offlining where cpus_allowed

Quoted 1 line

effective_cpus + reserved_cpus can happen.

Quoted 8 lines

One reason for doing so is because reserved_cpus is hidden. So the main way to infer that is to do cpus_allowed - effective_cpus.

It is probably doable to make cpus_allowed >= effective_cpus + reserved_cpus in general, but we may need to expose reserved_cpus as a read-only file, for instance. There may also be other complications that we will need to take care of if this is supported. My current preference is to not doing that unless there is compelling reason to do so.

So, if we're gonna make this hierarchical, I think it probably would be better to go in all the way. It's kinda weird to mix the two approaches - the normal cpuset operation following the usual convention (it'd be really great to fix the removal part too) and parition code doing something else.

I think adding another interface file should be fine here.

Thanks.

Signature · 1 line
tejun
author maintainer
#15 lore raw

Re: [PATCH v12 9/9] cpuset: Support forced turning off of partition flag

Quoted 30 lines · Tejun Heo

Hello, Waiman.

My apologies for the delay.

Quoted 11 lines · Waiman Long

My current code has explicitly assumed the following relationship for partition root.

cpus_allowed = effective_cpus + reserved_cpus

Also effective_cpus cannot be empty. Specifically, cpus_allowed has to be equal to effective_cpus before a cpuset can be made a partition root.

Any changes that break the above conditions will turn off the partition flag forcefully. The only exception is cpu offlining where cpus_allowed

Quoted 1 line

effective_cpus + reserved_cpus can happen.

Quoted 8 lines

One reason for doing so is because reserved_cpus is hidden. So the main way to infer that is to do cpus_allowed - effective_cpus.

It is probably doable to make cpus_allowed >= effective_cpus + reserved_cpus in general, but we may need to expose reserved_cpus as a read-only file, for instance. There may also be other complications that we will need to take care of if this is supported. My current preference is to not doing that unless there is compelling reason to do so.

So, if we're gonna make this hierarchical, I think it probably would be better to go in all the way. It's kinda weird to mix the two approaches - the normal cpuset operation following the usual convention (it'd be really great to fix the removal part too) and parition code doing something else.

Quoted 4 lines

I think adding another interface file should be fine here.

Thanks.

OK, I will revise the patch to make it work without the removal part.

Thanks,
Longman