s390x: Fixup svc handling
A message that is not in the archive (sent off-list or not yet received): [email protected]
Cornelia Huck
Reviewed-byQuoted 26 lines · On Thu, 8 Nov 2018 10:27:04 +0100 Janosch Frank <[email protected]> wrote:
Let's use the svc psw instead of the mccheck psw for svc interrupts and name it supervisor call.
Signed-off-by Janosch Frank <[email protected]>--- lib/s390x/interrupt.c | 2 +- s390x/cstart64.S | 2 +- 2 files changed, 2 insertions(+), 2 deletions(-)lib/s390x/interrupt.c +1
-1@@ -137,6 +137,6 @@ void handle_io_int(void)void handle_svc_int (void ) { -report_abort ("Unexpected service call interrupt: at %#lx" , +report_abort ("Unexpected supervisor call interrupt: at %#lx" , lc->svc_old_psw.addr); }s390x/cstart64.S +0
-0
s390x/cstart64.S init_psw_cont: · line 36
Quoted 1 line
s390x/cstart64.S +0
-0@@ -36,7 +36,7 @@ init_psw_cont: larl %r1, ext_int_psw
Hm... shouldn't that be io_int_psw here? (The other psws look fine.)
s390x/cstart64.S init_psw_cont: · line 42
Quoted 7 lines
s390x/cstart64.S +1
-1mvc GEN_LC_IO_NEW_PSW(16), 0(%r1) /* setup svc interrupt handler */ - larl %r1, mcck_int_psw + larl %r1, svc_int_psw mvc GEN_LC_SVC_NEW_PSW(16), 0(%r1) /* setup cr0, enabling e.g. AFP-register control */ larl %r1, initial_cr0
Reviewed-by Cornelia Huck <[email protected]>