sdhci: fix the fake timeout bug

PATCH In review Du, Alek 3 participants 14 messages Nov 30, 2018 – Dec 6, 2018

Subsystems (2)
lore
Share & tools
lore

Du, Alek

author
#0 lore raw

PATCH 1/1 sdhci: fix the fake timeout bug

Quoted 1 line

From b893df3a1a937bd5fe22d39ceae93454a2e5e0e4 Mon Sep 17 00:00:00 2001

From: Alek Du <[email protected]>
Date: Fri, 30 Nov 2018 14:02:28 +0800
Subject: [PATCH] sdhci: fix the fake timeout bug

We observed some fake timeouts on some devices, the log is like this:

[ 7586.290201] mmc1: Timeout waiting for hardware cmd interrupt.
[ 7586.290420] mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
...
[ 7586.291774] mmc1: sdhci: Wake-up:   0x00000000 | Clock:    0x00000203
Quoted 1 line

From the clock control register dump, we are pretty sure the clock was

stabilized.

In other cases, we also observed:

[ 7596.530171] mmc1: Timeout waiting for hardware cmd interrupt.

and

[ 1956.534634] mmc1: Reset 0x2 never completed.

But we are pretty sure the mmc controller is working perfectly under low system load.

After checking the sdhci code, we found the timeout check actually has a little window that the CPU can be scheduled out and when it comes back, the original time set or check is not valid.

---
 drivers/mmc/host/sdhci.c | 19 ++++++++++++++++---
 1 file changed, 16 insertions(+), 3 deletions(-)
drivers/mmc/host/sdhci.c +16 -3
index 99bdae53fa2e..f88c49fc574e 100644
@@ -218,12 +218,17 @@ void sdhci_reset(struct sdhci_host *host, u8 mask)
 	/* hw clears the bit when it's done */
 	while (sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask) {
 		if (ktime_after(ktime_get(), timeout)) {
+			/* check it again, since there is a window between
+			   bit check and time check */
+			if (!(sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask))
+				break;
 			pr_err("%s: Reset 0x%x never completed.\n",
 				mmc_hostname(host->mmc), (int)mask);
 			sdhci_dumpregs(host);
 			return;
+		} else {
+			udelay(10);
 		}
-		udelay(10);
 	}
 }
 EXPORT_SYMBOL_GPL(sdhci_reset);
@@ -1395,9 +1400,10 @@ void sdhci_send_command(struct sdhci_host *host, struct mmc_command *cmd)
 		timeout += DIV_ROUND_UP(cmd->busy_timeout, 1000) * HZ + HZ;
 	else
 		timeout += 10 * HZ;
-	sdhci_mod_timer(host, cmd->mrq, timeout);
 
 	sdhci_writew(host, SDHCI_MAKE_CMD(cmd->opcode, flags), SDHCI_COMMAND);
+	/* setup timer after command to avoid fake timeout */
+	sdhci_mod_timer(host, cmd->mrq, timeout);
 }
 EXPORT_SYMBOL_GPL(sdhci_send_command);
 
@@ -1611,12 +1617,19 @@ void sdhci_enable_clk(struct sdhci_host *host, u16 clk)
 	while (!((clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL))
 		& SDHCI_CLOCK_INT_STABLE)) {
 		if (ktime_after(ktime_get(), timeout)) {
+			/* check it again since there is a window between
+			   status check and time check */
+			if ((clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL))
+					& SDHCI_CLOCK_INT_STABLE)
+				break;
 			pr_err("%s: Internal clock never stabilised.\n",
 			       mmc_hostname(host->mmc));
 			sdhci_dumpregs(host);
 			return;
 		}
-		udelay(10);
+		else {
+			udelay(10);
+		}
 	}
 
 	clk |= SDHCI_CLOCK_CARD_EN;
Signature · 1 line
2.17.1
maintainer
#1 lore raw
Quoted 21 lines · Alek
Quoted 1 line

From b893df3a1a937bd5fe22d39ceae93454a2e5e0e4 Mon Sep 17 00:00:00 2001

From: Alek Du <[email protected]>
Date: Fri, 30 Nov 2018 14:02:28 +0800
Subject: [PATCH] sdhci: fix the fake timeout bug

We observed some fake timeouts on some devices, the log is like this:

[ 7586.290201] mmc1: Timeout waiting for hardware cmd interrupt.
[ 7586.290420] mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
...
[ 7586.291774] mmc1: sdhci: Wake-up:   0x00000000 | Clock:    0x00000203
Quoted 1 line

From the clock control register dump, we are pretty sure the clock was

stabilized.

In other cases, we also observed:

[ 7596.530171] mmc1: Timeout waiting for hardware cmd interrupt.

and

Quoted 8 lines
[ 1956.534634] mmc1: Reset 0x2 never completed.

But we are pretty sure the mmc controller is working perfectly under low system load.

After checking the sdhci code, we found the timeout check actually has a little window that the CPU can be scheduled out and when it comes back, the original time set or check is not valid.

Commands and resets are under spin lock, so no possibility for preemption, and certainly a few microseconds isn't going to make any difference to these timeouts, so I don't see how this patch could help.

I recently sent a patch for GLK laptops that had BIOS issues:

	https://marc.info/?l=linux-mmc&m=154270005901609

And also some improvements to error handling:

	https://marc.info/?l=linux-mmc&m=154229013900437

If those don't help, please share more details of the actual problem.

Quoted 63 lines
---
 drivers/mmc/host/sdhci.c | 19 ++++++++++++++++---
 1 file changed, 16 insertions(+), 3 deletions(-)
drivers/mmc/host/sdhci.c +16 -3
index 99bdae53fa2e..f88c49fc574e 100644
@@ -218,12 +218,17 @@ void sdhci_reset(struct sdhci_host *host, u8 mask)
 	/* hw clears the bit when it's done */
 	while (sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask) {
 		if (ktime_after(ktime_get(), timeout)) {
+			/* check it again, since there is a window between
+			   bit check and time check */
+			if (!(sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask))
+				break;
 			pr_err("%s: Reset 0x%x never completed.\n",
 				mmc_hostname(host->mmc), (int)mask);
 			sdhci_dumpregs(host);
 			return;
+		} else {
+			udelay(10);
 		}
-		udelay(10);
 	}
 }
 EXPORT_SYMBOL_GPL(sdhci_reset);
@@ -1395,9 +1400,10 @@ void sdhci_send_command(struct sdhci_host *host, struct mmc_command *cmd)
 		timeout += DIV_ROUND_UP(cmd->busy_timeout, 1000) * HZ + HZ;
 	else
 		timeout += 10 * HZ;
-	sdhci_mod_timer(host, cmd->mrq, timeout);
 
 	sdhci_writew(host, SDHCI_MAKE_CMD(cmd->opcode, flags), SDHCI_COMMAND);
+	/* setup timer after command to avoid fake timeout */
+	sdhci_mod_timer(host, cmd->mrq, timeout);
 }
 EXPORT_SYMBOL_GPL(sdhci_send_command);
 
@@ -1611,12 +1617,19 @@ void sdhci_enable_clk(struct sdhci_host *host, u16 clk)
 	while (!((clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL))
 		& SDHCI_CLOCK_INT_STABLE)) {
 		if (ktime_after(ktime_get(), timeout)) {
+			/* check it again since there is a window between
+			   status check and time check */
+			if ((clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL))
+					& SDHCI_CLOCK_INT_STABLE)
+				break;
 			pr_err("%s: Internal clock never stabilised.\n",
 			       mmc_hostname(host->mmc));
 			sdhci_dumpregs(host);
 			return;
 		}
-		udelay(10);
+		else {
+			udelay(10);
+		}
 	}
 
 	clk |= SDHCI_CLOCK_CARD_EN;
author
#2 lore raw
Quoted 4 lines · On Fri, 30 Nov 2018 11:19:03 +0200 Adrian Hunter <[email protected]>…

Commands and resets are under spin lock, so no possibility for preemption, and certainly a few microseconds isn't going to make any difference to these timeouts, so I don't see how this patch could help.

Thanks for your review.

I believe my case the scheduling out delay sometime can reach 10~20 milliseconds... This may be due to the hypervisor...

Please look at the sdhci_enable_clk() below, there is a window in clock stabilization check. The first check is to check status register, the second check is to check if time passed. That's why I can capture a case that after time passed, the actually clock control register indicated that clock is stable. So the error handling is wrong...

Also the sdhci_send_command commands is not in spin lock There is a windows between mod_timer and real command send...

Thanks,
Alek

Quoted 10 lines

I recently sent a patch for GLK laptops that had BIOS issues:

	https://marc.info/?l=linux-mmc&m=154270005901609

And also some improvements to error handling:

	https://marc.info/?l=linux-mmc&m=154229013900437

If those don't help, please share more details of the actual problem.

Sorry, I can't see how this patches could fix my problem.

Quoted 70 lines
Quoted 69 lines
---
 drivers/mmc/host/sdhci.c | 19 ++++++++++++++++---
 1 file changed, 16 insertions(+), 3 deletions(-)
drivers/mmc/host/sdhci.c +0 -0
index 99bdae53fa2e..f88c49fc574e 100644
@@ -218,12 +218,17 @@ void sdhci_reset(struct sdhci_host *host, u8

mask) /* hw clears the bit when it's done */

drivers/mmc/host/sdhci.c +1 -0
 	while (sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask) {
 		if (ktime_after(ktime_get(), timeout)) {
+			/* check it again, since there is a window

between

drivers/mmc/host/sdhci.c +2 -0
+			   bit check and time check */
+			if (!(sdhci_readb(host,

SDHCI_SOFTWARE_RESET) & mask))

drivers/mmc/host/sdhci.c +1 -0
+				break;
 			pr_err("%s: Reset 0x%x never completed.\n",
 				mmc_hostname(host->mmc),

(int)mask); sdhci_dumpregs(host);

drivers/mmc/host/sdhci.c +2 -1
 			return;
+		} else {
+			udelay(10);
 		}
-		udelay(10);
 	}
 }
 EXPORT_SYMBOL_GPL(sdhci_reset);
@@ -1395,9 +1400,10 @@ void sdhci_send_command(struct sdhci_host
 *host, struct mmc_command *cmd) timeout +=

DIV_ROUND_UP(cmd->busy_timeout, 1000) * HZ + HZ; else

drivers/mmc/host/sdhci.c +0 -1
 		timeout += 10 * HZ;
-	sdhci_mod_timer(host, cmd->mrq, timeout);
 
 	sdhci_writew(host, SDHCI_MAKE_CMD(cmd->opcode, flags),

SDHCI_COMMAND);

drivers/mmc/host/sdhci.c +3 -0
+	/* setup timer after command to avoid fake timeout */
+	sdhci_mod_timer(host, cmd->mrq, timeout);
 }
 EXPORT_SYMBOL_GPL(sdhci_send_command);
@@ -1611,12 +1617,19 @@ void sdhci_enable_clk(struct sdhci_host
 *host, u16 clk) while (!((clk = sdhci_readw(host,
 SDHCI_CLOCK_CONTROL)) & SDHCI_CLOCK_INT_STABLE)) {
 		if (ktime_after(ktime_get(), timeout)) {
+			/* check it again since there is a window

between

drivers/mmc/host/sdhci.c +2 -0
+			   status check and time check */
+			if ((clk = sdhci_readw(host,

SDHCI_CLOCK_CONTROL))

drivers/mmc/host/sdhci.c +2 -0
+					& SDHCI_CLOCK_INT_STABLE)
+				break;
 			pr_err("%s: Internal clock never

stabilised.\n", mmc_hostname(host->mmc));

drivers/mmc/host/sdhci.c +3 -1
 			sdhci_dumpregs(host);
 			return;
 		}
-		udelay(10);
+		else {
+			udelay(10);
+		}
 	}
 
 	clk |= SDHCI_CLOCK_CARD_EN;
maintainer
#3 lore raw
Quoted 8 lines · Alek
Quoted 4 lines · On Fri, 30 Nov 2018 11:19:03 +0200 Adrian Hunter <[email protected]>…

Commands and resets are under spin lock, so no possibility for preemption, and certainly a few microseconds isn't going to make any difference to these timeouts, so I don't see how this patch could help.

Quoted 4 lines

Thanks for your review.

I believe my case the scheduling out delay sometime can reach 10~20 milliseconds... This may be due to the hypervisor...

So you are saying this only happens under virtualization?

Quoted 6 lines

Please look at the sdhci_enable_clk() below, there is a window in clock stabilization check. The first check is to check status register, the second check is to check if time passed. That's why I can capture a case that after time passed, the actually clock control register indicated that clock is stable. So the error handling is wrong...

Sure, but "Internal clock never stabilised." is not one of the errors you listed.

Quoted 3 lines

Also the sdhci_send_command commands is not in spin lock There is a windows between mod_timer and real command send...

What code path does not have a spin lock?

Quoted 91 lines

Thanks,
Alek

Quoted 10 lines

I recently sent a patch for GLK laptops that had BIOS issues:

	https://marc.info/?l=linux-mmc&m=154270005901609

And also some improvements to error handling:

	https://marc.info/?l=linux-mmc&m=154229013900437

If those don't help, please share more details of the actual problem.

Sorry, I can't see how this patches could fix my problem.

Quoted 70 lines
Quoted 69 lines
---
 drivers/mmc/host/sdhci.c | 19 ++++++++++++++++---
 1 file changed, 16 insertions(+), 3 deletions(-)
drivers/mmc/host/sdhci.c +0 -0
index 99bdae53fa2e..f88c49fc574e 100644
@@ -218,12 +218,17 @@ void sdhci_reset(struct sdhci_host *host, u8

mask) /* hw clears the bit when it's done */

drivers/mmc/host/sdhci.c +1 -0
 	while (sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask) {
 		if (ktime_after(ktime_get(), timeout)) {
+			/* check it again, since there is a window

between

drivers/mmc/host/sdhci.c +2 -0
+			   bit check and time check */
+			if (!(sdhci_readb(host,

SDHCI_SOFTWARE_RESET) & mask))

drivers/mmc/host/sdhci.c +1 -0
+				break;
 			pr_err("%s: Reset 0x%x never completed.\n",
 				mmc_hostname(host->mmc),

(int)mask); sdhci_dumpregs(host);

drivers/mmc/host/sdhci.c +2 -1
 			return;
+		} else {
+			udelay(10);
 		}
-		udelay(10);
 	}
 }
 EXPORT_SYMBOL_GPL(sdhci_reset);
@@ -1395,9 +1400,10 @@ void sdhci_send_command(struct sdhci_host
 *host, struct mmc_command *cmd) timeout +=

DIV_ROUND_UP(cmd->busy_timeout, 1000) * HZ + HZ; else

drivers/mmc/host/sdhci.c +0 -1
 		timeout += 10 * HZ;
-	sdhci_mod_timer(host, cmd->mrq, timeout);
 
 	sdhci_writew(host, SDHCI_MAKE_CMD(cmd->opcode, flags),

SDHCI_COMMAND);

drivers/mmc/host/sdhci.c +3 -0
+	/* setup timer after command to avoid fake timeout */
+	sdhci_mod_timer(host, cmd->mrq, timeout);
 }
 EXPORT_SYMBOL_GPL(sdhci_send_command);
@@ -1611,12 +1617,19 @@ void sdhci_enable_clk(struct sdhci_host
 *host, u16 clk) while (!((clk = sdhci_readw(host,
 SDHCI_CLOCK_CONTROL)) & SDHCI_CLOCK_INT_STABLE)) {
 		if (ktime_after(ktime_get(), timeout)) {
+			/* check it again since there is a window

between

drivers/mmc/host/sdhci.c +2 -0
+			   status check and time check */
+			if ((clk = sdhci_readw(host,

SDHCI_CLOCK_CONTROL))

drivers/mmc/host/sdhci.c +2 -0
+					& SDHCI_CLOCK_INT_STABLE)
+				break;
 			pr_err("%s: Internal clock never

stabilised.\n", mmc_hostname(host->mmc));

drivers/mmc/host/sdhci.c +3 -1
 			sdhci_dumpregs(host);
 			return;
 		}
-		udelay(10);
+		else {
+			udelay(10);
+		}
 	}
 
 	clk |= SDHCI_CLOCK_CARD_EN;
author
#4 lore raw
Quoted 2 lines · On Fri, 30 Nov 2018 16:40:04 +0200 Adrian Hunter <[email protected]>…

So you are saying this only happens under virtualization?

Yes, I saw the issue under ACRN virtualization Service OS (4.19 kernel). But theoretically it can happen in other case when scheduling is not that good. (due to bad driver or other high priority task)

Quoted 10 lines
Quoted 7 lines

Please look at the sdhci_enable_clk() below, there is a window in clock stabilization check. The first check is to check status register, the second check is to check if time passed. That's why I can capture a case that after time passed, the actually clock control register indicated that clock is stable. So the error handling is wrong...

Sure, but "Internal clock never stabilised." is not one of the errors you listed.

Sorry my bad not listing all the error log:

Case 1. clock stabilization timeout: (the below clock control dump shows clock is good)

[159525.255629] mmc1: Internal clock never stabilised.
[159525.255818] mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
[159525.256049] mmc1: sdhci: Sys addr:  0x00000000 | Version:  0x00001002
[159525.256277] mmc1: sdhci: Blk size:  0x00000000 | Blk cnt:  0x00000000
[159525.256523] mmc1: sdhci: Argument:  0x00000000 | Trn mode: 0x00000000
[159525.256752] mmc1: sdhci: Present:   0x1fff0000 | Host ctl: 0x00000000
[159525.256979] mmc1: sdhci: Power:     0x0000000b | Blk gap:  0x00000080
[159525.257205] mmc1: sdhci: Wake-up:   0x00000000 | Clock:    0x0000fa03

Case 2. Reset timeout: (the same check window in sdhci_reset())

[ 7639.968613] mmc1: Reset 0x4 never completed.

Case 3. Hardware interrupt timeout

[ 1049.561728] mmc1: Timeout waiting for hardware interrupt.
Quoted 6 lines
Quoted 4 lines

Also the sdhci_send_command commands is not in spin lock There is a windows between mod_timer and real command send...

What code path does not have a spin lock?

Ouch my bad, the sdhci_send_command are called either from spinlock or IRQ handler, so this part is good ...

I'll send a new patch to cover case 1 and case 2 if you agree.

Thanks,
Alek

author
#5 lore raw

PATCH v2 1/1 sdhci: fix the timeout check window for clock and reset

Quoted 1 line

From 87692fc090978bde8fe872f02d0023a57af6b492 Mon Sep 17 00:00:00 2001

From: Alek Du <[email protected]>
Date: Fri, 30 Nov 2018 14:02:28 +0800
Subject: [PATCH] sdhci: fix the timeout check window for clock and reset

We observed some fake timeouts on some devices, the log is like this:

case 1:

[159525.255629] mmc1: Internal clock never stabilised.
[159525.255818] mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
[159525.256049] mmc1: sdhci: Sys addr:  0x00000000 | Version:  0x00001002
[159525.256277] mmc1: sdhci: Blk size:  0x00000000 | Blk cnt:  0x00000000
[159525.256523] mmc1: sdhci: Argument:  0x00000000 | Trn mode: 0x00000000
[159525.256752] mmc1: sdhci: Present:   0x1fff0000 | Host ctl: 0x00000000
[159525.256979] mmc1: sdhci: Power:     0x0000000b | Blk gap:  0x00000080
[159525.257205] mmc1: sdhci: Wake-up:   0x00000000 | Clock:    0x0000fa03
Quoted 1 line

From the clock control register dump, we are pretty sure the clock was

stablized.

case 2:

[  914.550127] mmc1: Reset 0x2 never completed.
[  914.550321] mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
[  914.550608] mmc1: sdhci: Sys addr:  0x00000010 | Version:  0x00001002

After checking the sdhci code, we found the timeout check actually has a little window that the CPU can be scheduled out and when it comes back, the original time set or check is not valid.

---
 drivers/mmc/host/sdhci.c | 16 ++++++++++++++--
 1 file changed, 14 insertions(+), 2 deletions(-)
drivers/mmc/host/sdhci.c +14 -2
index 99bdae53fa2e..af01f7d16eae 100644
@@ -218,12 +218,17 @@ void sdhci_reset(struct sdhci_host *host, u8 mask)
 	/* hw clears the bit when it's done */
 	while (sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask) {
 		if (ktime_after(ktime_get(), timeout)) {
+			/* check it again, since there is a window between
+			   bit check and time check */
+			if (!(sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask))
+				break;
 			pr_err("%s: Reset 0x%x never completed.\n",
 				mmc_hostname(host->mmc), (int)mask);
 			sdhci_dumpregs(host);
 			return;
+		} else {
+			udelay(10);
 		}
-		udelay(10);
 	}
 }
 EXPORT_SYMBOL_GPL(sdhci_reset);
@@ -1611,12 +1616,19 @@ void sdhci_enable_clk(struct sdhci_host *host, u16 clk)
 	while (!((clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL))
 		& SDHCI_CLOCK_INT_STABLE)) {
 		if (ktime_after(ktime_get(), timeout)) {
+			/* check it again since there is a window between
+			   status check and time check */
+			if ((clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL))
+					& SDHCI_CLOCK_INT_STABLE)
+				break;
 			pr_err("%s: Internal clock never stabilised.\n",
 			       mmc_hostname(host->mmc));
 			sdhci_dumpregs(host);
 			return;
 		}
-		udelay(10);
+		else {
+			udelay(10);
+		}
 	}
 
 	clk |= SDHCI_CLOCK_CARD_EN;
Signature · 1 line
2.17.1
maintainer
#6 lore raw

Re: [PATCH V2] sdhci: fix the timeout check window for clock and reset

Quoted 6 lines · Alek
Quoted 1 line

From 87692fc090978bde8fe872f02d0023a57af6b492 Mon Sep 17 00:00:00 2001

From: Alek Du <[email protected]>
Date: Fri, 30 Nov 2018 14:02:28 +0800
Subject: [PATCH] sdhci: fix the timeout check window for clock and reset

We observed some fake timeouts on some devices, the log is like this:

Please change "fake timeouts" to "premature timeouts". Also I think it is worth mentioning that this was with a virtualized environment.

Quoted 18 lines

case 1:

[159525.255629] mmc1: Internal clock never stabilised.
[159525.255818] mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
[159525.256049] mmc1: sdhci: Sys addr:  0x00000000 | Version:  0x00001002
[159525.256277] mmc1: sdhci: Blk size:  0x00000000 | Blk cnt:  0x00000000
[159525.256523] mmc1: sdhci: Argument:  0x00000000 | Trn mode: 0x00000000
[159525.256752] mmc1: sdhci: Present:   0x1fff0000 | Host ctl: 0x00000000
[159525.256979] mmc1: sdhci: Power:     0x0000000b | Blk gap:  0x00000080
[159525.257205] mmc1: sdhci: Wake-up:   0x00000000 | Clock:    0x0000fa03
Quoted 1 line

From the clock control register dump, we are pretty sure the clock was

stablized.

case 2:

[  914.550127] mmc1: Reset 0x2 never completed.
[  914.550321] mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
[  914.550608] mmc1: sdhci: Sys addr:  0x00000010 | Version:  0x00001002
Quoted 5 lines

After checking the sdhci code, we found the timeout check actually has a little window that the CPU can be scheduled out and when it comes back, the original time set or check is not valid.

Please add fixes tag:

Fixes 5a436cc0af62 ("mmc: sdhci: Optimize delay loops")

And also a stable tag:

Cc [email protected] # v4.12+
Quoted 9 lines
---
 drivers/mmc/host/sdhci.c | 16 ++++++++++++++--
 1 file changed, 14 insertions(+), 2 deletions(-)
drivers/mmc/host/sdhci.c +0 -0
index 99bdae53fa2e..af01f7d16eae 100644

drivers/mmc/host/sdhci.c void sdhci_reset(struct sdhci_host *host, u8 mask) · line 224

Quoted 7 lines
drivers/mmc/host/sdhci.c +4 -0
@@ -218,12 +218,17 @@ void sdhci_reset(struct sdhci_host *host, u8 mask)
 	/* hw clears the bit when it's done */
 	while (sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask) {
 		if (ktime_after(ktime_get(), timeout)) {
+			/* check it again, since there is a window between
+			   bit check and time check */
+			if (!(sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask))
+				break;

It would be neater like:

	while (1) {
		bool timedout = ktime_after(ktime_get(), timeout);

		if (!(sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask))
			break;
		if (timedout) {

drivers/mmc/host/sdhci.c void sdhci_reset(struct sdhci_host *host, u8 mask) · line 229

Quoted 5 lines
drivers/mmc/host/sdhci.c +1 -0
 			pr_err("%s: Reset 0x%x never completed.\n",
 				mmc_hostname(host->mmc), (int)mask);
 			sdhci_dumpregs(host);
 			return;
+		} else {

The if-clause does a 'return', so the 'else' is not needed

Quoted 7 lines
drivers/mmc/host/sdhci.c +1 -1
+			udelay(10);
 		}
-		udelay(10);
 	}
 }
 EXPORT_SYMBOL_GPL(sdhci_reset);

drivers/mmc/host/sdhci.c void sdhci_enable_clk(struct sdhci_host *host, u16 clk) · line 1623

Quoted 8 lines
drivers/mmc/host/sdhci.c +5 -0
@@ -1611,12 +1616,19 @@ void sdhci_enable_clk(struct sdhci_host *host, u16 clk)
 	while (!((clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL))
 		& SDHCI_CLOCK_INT_STABLE)) {
 		if (ktime_after(ktime_get(), timeout)) {
+			/* check it again since there is a window between
+			   status check and time check */
+			if ((clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL))
+					& SDHCI_CLOCK_INT_STABLE)
+				break;

Similarly:

	while (1) {
		bool timedout = ktime_after(ktime_get(), timeout);

		clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL);
		if (clk & SDHCI_CLOCK_INT_STABLE)
			break;
		if (timedout) {

drivers/mmc/host/sdhci.c void sdhci_enable_clk(struct sdhci_host *host, u16 clk) · line 1629

Quoted 7 lines
drivers/mmc/host/sdhci.c +1 -1
 			pr_err("%s: Internal clock never stabilised.\n",
 			       mmc_hostname(host->mmc));
 			sdhci_dumpregs(host);
 			return;
 		}
-		udelay(10);
+		else {

The if-clause does a 'return', so the 'else' is not needed

Quoted 6 lines
drivers/mmc/host/sdhci.c +2 -0
+			udelay(10);
+		}
 	}
 
 	clk |= SDHCI_CLOCK_CARD_EN;
author
#7 lore raw

PATCH v3 1/1 sdhci: fix the timeout check window for clock and reset

Quoted 1 line

From bcb38577961823b4f8f2cc0aec7dd450a81b6ddc Mon Sep 17 00:00:00 2001

From: Alek Du <[email protected]>
Date: Fri, 30 Nov 2018 14:02:28 +0800
Subject: [PATCH] sdhci: fix the timeout check window for clock and reset

We observed some premature timeouts on a virtualization platform, the log is like this:

case 1:

[159525.255629] mmc1: Internal clock never stabilised.
[159525.255818] mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
[159525.256049] mmc1: sdhci: Sys addr:  0x00000000 | Version:  0x00001002
...
[159525.257205] mmc1: sdhci: Wake-up:   0x00000000 | Clock:    0x0000fa03
Quoted 1 line

From the clock control register dump, we are pretty sure the clock was

stablized.

case 2:

[  914.550127] mmc1: Reset 0x2 never completed.
[  914.550321] mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
[  914.550608] mmc1: sdhci: Sys addr:  0x00000010 | Version:  0x00001002

After checking the sdhci code, we found the timeout check actually has a little window that the CPU can be scheduled out and when it comes back, the original time set or check is not valid.

Fixes 5a436cc0af62 ("mmc: sdhci: Optimize delay loops")
Cc [email protected] # v4.12+
---
 drivers/mmc/host/sdhci.c | 18 +++++++++++++-----
 1 file changed, 13 insertions(+), 5 deletions(-)
drivers/mmc/host/sdhci.c +13 -5
index 99bdae53fa2e..451b08a818a9 100644
@@ -216,8 +216,12 @@ void sdhci_reset(struct sdhci_host *host, u8 mask)
 	timeout = ktime_add_ms(ktime_get(), 100);
 
 	/* hw clears the bit when it's done */
-	while (sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask) {
-		if (ktime_after(ktime_get(), timeout)) {
+	while (1) {
+		bool timedout = ktime_after(ktime_get(), timeout);
+
+		if (!(sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask))
+			break;
+		if (timedout) {
 			pr_err("%s: Reset 0x%x never completed.\n",
 				mmc_hostname(host->mmc), (int)mask);
 			sdhci_dumpregs(host);
@@ -1608,9 +1612,13 @@ void sdhci_enable_clk(struct sdhci_host *host, u16 clk)
 
 	/* Wait max 20 ms */
 	timeout = ktime_add_ms(ktime_get(), 20);
-	while (!((clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL))
-		& SDHCI_CLOCK_INT_STABLE)) {
-		if (ktime_after(ktime_get(), timeout)) {
+	while (1) {
+		bool timedout = ktime_after(ktime_get(), timeout);
+
+		clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL);
+		if (clk & SDHCI_CLOCK_INT_STABLE)
+			break;
+		if (timedout) {
 			pr_err("%s: Internal clock never stabilised.\n",
 			       mmc_hostname(host->mmc));
 			sdhci_dumpregs(host);
Signature · 1 line
2.17.1
maintainer Acked-by on v3 1/1
#8 lore raw

Re: [PATCH V3] sdhci: fix the timeout check window for clock and reset

Quoted 22 lines · Alek
Quoted 1 line

From bcb38577961823b4f8f2cc0aec7dd450a81b6ddc Mon Sep 17 00:00:00 2001

From: Alek Du <[email protected]>
Date: Fri, 30 Nov 2018 14:02:28 +0800
Subject: [PATCH] sdhci: fix the timeout check window for clock and reset

We observed some premature timeouts on a virtualization platform, the log is like this:

case 1:

[159525.255629] mmc1: Internal clock never stabilised.
[159525.255818] mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
[159525.256049] mmc1: sdhci: Sys addr:  0x00000000 | Version:  0x00001002
...
[159525.257205] mmc1: sdhci: Wake-up:   0x00000000 | Clock:    0x0000fa03
Quoted 1 line

From the clock control register dump, we are pretty sure the clock was

stablized.

case 2:

[  914.550127] mmc1: Reset 0x2 never completed.
[  914.550321] mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
[  914.550608] mmc1: sdhci: Sys addr:  0x00000010 | Version:  0x00001002
Quoted 7 lines

After checking the sdhci code, we found the timeout check actually has a little window that the CPU can be scheduled out and when it comes back, the original time set or check is not valid.

Fixes 5a436cc0af62 ("mmc: sdhci: Optimize delay loops")
Cc [email protected] # v4.12+
Quoted 41 lines
---
 drivers/mmc/host/sdhci.c | 18 +++++++++++++-----
 1 file changed, 13 insertions(+), 5 deletions(-)
drivers/mmc/host/sdhci.c +13 -5
index 99bdae53fa2e..451b08a818a9 100644
@@ -216,8 +216,12 @@ void sdhci_reset(struct sdhci_host *host, u8 mask)
 	timeout = ktime_add_ms(ktime_get(), 100);
 
 	/* hw clears the bit when it's done */
-	while (sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask) {
-		if (ktime_after(ktime_get(), timeout)) {
+	while (1) {
+		bool timedout = ktime_after(ktime_get(), timeout);
+
+		if (!(sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask))
+			break;
+		if (timedout) {
 			pr_err("%s: Reset 0x%x never completed.\n",
 				mmc_hostname(host->mmc), (int)mask);
 			sdhci_dumpregs(host);
@@ -1608,9 +1612,13 @@ void sdhci_enable_clk(struct sdhci_host *host, u16 clk)
 
 	/* Wait max 20 ms */
 	timeout = ktime_add_ms(ktime_get(), 20);
-	while (!((clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL))
-		& SDHCI_CLOCK_INT_STABLE)) {
-		if (ktime_after(ktime_get(), timeout)) {
+	while (1) {
+		bool timedout = ktime_after(ktime_get(), timeout);
+
+		clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL);
+		if (clk & SDHCI_CLOCK_INT_STABLE)
+			break;
+		if (timedout) {
 			pr_err("%s: Internal clock never stabilised.\n",
 			       mmc_hostname(host->mmc));
 			sdhci_dumpregs(host);
#9 lore raw

Re: [PATCH V3] sdhci: fix the timeout check window for clock and reset

In reply to Du, Alek
Quoted 5 lines · Alek

From bcb38577961823b4f8f2cc0aec7dd450a81b6ddc Mon Sep 17 00:00:00 2001
From: Alek Du <[email protected]>
Date: Fri, 30 Nov 2018 14:02:28 +0800
Subject: [PATCH] sdhci: fix the timeout check window for clock and reset

Please change the prefix to: "mmc: sdhci".

Quoted 18 lines

We observed some premature timeouts on a virtualization platform, the log is like this:

case 1:

[159525.255629] mmc1: Internal clock never stabilised.
[159525.255818] mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
[159525.256049] mmc1: sdhci: Sys addr:  0x00000000 | Version:  0x00001002
...
[159525.257205] mmc1: sdhci: Wake-up:   0x00000000 | Clock:    0x0000fa03

From the clock control register dump, we are pretty sure the clock was stablized.

case 2:

[  914.550127] mmc1: Reset 0x2 never completed.
[  914.550321] mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
[  914.550608] mmc1: sdhci: Sys addr:  0x00000010 | Version:  0x00001002
Quoted 7 lines

After checking the sdhci code, we found the timeout check actually has a little window that the CPU can be scheduled out and when it comes back, the original time set or check is not valid.

Fixes 5a436cc0af62 ("mmc: sdhci: Optimize delay loops")
Cc [email protected] # v4.12+

I intended to queue this up as fix, but couldn't apply it. Can you please re-base this on top of v4.20-rc5 or later?

Kind regards
Uffe

Quoted 42 lines
---
 drivers/mmc/host/sdhci.c | 18 +++++++++++++-----
 1 file changed, 13 insertions(+), 5 deletions(-)
drivers/mmc/host/sdhci.c +13 -6
index 99bdae53fa2e..451b08a818a9 100644
@@ -216,8 +216,12 @@ void sdhci_reset(struct sdhci_host *host, u8 mask)
        timeout = ktime_add_ms(ktime_get(), 100);
 
        /* hw clears the bit when it's done */
-       while (sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask) {
-               if (ktime_after(ktime_get(), timeout)) {
+       while (1) {
+               bool timedout = ktime_after(ktime_get(), timeout);
+
+               if (!(sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask))
+                       break;
+               if (timedout) {
                        pr_err("%s: Reset 0x%x never completed.\n",
                                mmc_hostname(host->mmc), (int)mask);
                        sdhci_dumpregs(host);
@@ -1608,9 +1612,13 @@ void sdhci_enable_clk(struct sdhci_host *host, u16 clk)
 
        /* Wait max 20 ms */
        timeout = ktime_add_ms(ktime_get(), 20);
-       while (!((clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL))
-               & SDHCI_CLOCK_INT_STABLE)) {
-               if (ktime_after(ktime_get(), timeout)) {
+       while (1) {
+               bool timedout = ktime_after(ktime_get(), timeout);
+
+               clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL);
+               if (clk & SDHCI_CLOCK_INT_STABLE)
+                       break;
+               if (timedout) {
                        pr_err("%s: Internal clock never stabilised.\n",
                               mmc_hostname(host->mmc));
                        sdhci_dumpregs(host);
--

2.17.1

author
#10 lore raw

PATCH v3 1/1 mmc: sdhci: fix the timeout check window for clock and reset

Quoted 1 line

From a081e783383adf1179c71bc37b4e199d087af643 Mon Sep 17 00:00:00 2001

From: Alek Du <[email protected]>
Date: Fri, 30 Nov 2018 14:02:28 +0800
Subject: [PATCH] mmc: sdhci: fix the timeout check window for clock and reset

We observed some premature timeouts on a virtualization platform, the log is like this:

case 1:

[159525.255629] mmc1: Internal clock never stabilised.
[159525.255818] mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
[159525.256049] mmc1: sdhci: Sys addr:  0x00000000 | Version:  0x00001002
...
[159525.257205] mmc1: sdhci: Wake-up:   0x00000000 | Clock:    0x0000fa03
Quoted 1 line

From the clock control register dump, we are pretty sure the clock was

stablized.

case 2:

[  914.550127] mmc1: Reset 0x2 never completed.
[  914.550321] mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
[  914.550608] mmc1: sdhci: Sys addr:  0x00000010 | Version:  0x00001002

After checking the sdhci code, we found the timeout check actually has a little window that the CPU can be scheduled out and when it comes back, the original time set or check is not valid.

Fixes 5a436cc0af62 ("mmc: sdhci: Optimize delay loops")
Cc [email protected] # v4.12+
---
 drivers/mmc/host/sdhci.c | 18 +++++++++++++-----
 1 file changed, 13 insertions(+), 5 deletions(-)
drivers/mmc/host/sdhci.c +13 -5
index 99bdae53fa2e..451b08a818a9 100644
@@ -216,8 +216,12 @@ void sdhci_reset(struct sdhci_host *host, u8 mask)
 	timeout = ktime_add_ms(ktime_get(), 100);
 
 	/* hw clears the bit when it's done */
-	while (sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask) {
-		if (ktime_after(ktime_get(), timeout)) {
+	while (1) {
+		bool timedout = ktime_after(ktime_get(), timeout);
+
+		if (!(sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask))
+			break;
+		if (timedout) {
 			pr_err("%s: Reset 0x%x never completed.\n",
 				mmc_hostname(host->mmc), (int)mask);
 			sdhci_dumpregs(host);
@@ -1608,9 +1612,13 @@ void sdhci_enable_clk(struct sdhci_host *host, u16 clk)
 
 	/* Wait max 20 ms */
 	timeout = ktime_add_ms(ktime_get(), 20);
-	while (!((clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL))
-		& SDHCI_CLOCK_INT_STABLE)) {
-		if (ktime_after(ktime_get(), timeout)) {
+	while (1) {
+		bool timedout = ktime_after(ktime_get(), timeout);
+
+		clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL);
+		if (clk & SDHCI_CLOCK_INT_STABLE)
+			break;
+		if (timedout) {
 			pr_err("%s: Internal clock never stabilised.\n",
 			       mmc_hostname(host->mmc));
 			sdhci_dumpregs(host);
Signature · 1 line
2.17.1
#11 lore raw

Re: [PATCH V3 rebase] mmc: sdhci: fix the timeout check window for clock and reset

Quoted 23 lines · Alek

From a081e783383adf1179c71bc37b4e199d087af643 Mon Sep 17 00:00:00 2001
From: Alek Du <[email protected]>
Date: Fri, 30 Nov 2018 14:02:28 +0800
Subject: [PATCH] mmc: sdhci: fix the timeout check window for clock and reset

We observed some premature timeouts on a virtualization platform, the log is like this:

case 1:

[159525.255629] mmc1: Internal clock never stabilised.
[159525.255818] mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
[159525.256049] mmc1: sdhci: Sys addr:  0x00000000 | Version:  0x00001002
...
[159525.257205] mmc1: sdhci: Wake-up:   0x00000000 | Clock:    0x0000fa03

From the clock control register dump, we are pretty sure the clock was stablized.

case 2:

[  914.550127] mmc1: Reset 0x2 never completed.
[  914.550321] mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
[  914.550608] mmc1: sdhci: Sys addr:  0x00000010 | Version:  0x00001002
Quoted 7 lines

After checking the sdhci code, we found the timeout check actually has a little window that the CPU can be scheduled out and when it comes back, the original time set or check is not valid.

Fixes 5a436cc0af62 ("mmc: sdhci: Optimize delay loops")
Cc [email protected] # v4.12+

I am still not able to apply this, however the reason is not that a rebase is needed.

Instead it seems like the patch is malformed, exactly why I don't know. I am using patchwork to fetch the patch, but I even tried fetching it directly via my gmail client, no luck. In both case it can't be applied and checkpatch is also complaining.

Could you check at your side and see what can be wrong? If there is too much hazzle I can manually fixup the patch next week, as one time thing.

Kind regards
Uffe

Quoted 42 lines
---
 drivers/mmc/host/sdhci.c | 18 +++++++++++++-----
 1 file changed, 13 insertions(+), 5 deletions(-)
drivers/mmc/host/sdhci.c +13 -6
index 99bdae53fa2e..451b08a818a9 100644
@@ -216,8 +216,12 @@ void sdhci_reset(struct sdhci_host *host, u8 mask)
        timeout = ktime_add_ms(ktime_get(), 100);
 
        /* hw clears the bit when it's done */
-       while (sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask) {
-               if (ktime_after(ktime_get(), timeout)) {
+       while (1) {
+               bool timedout = ktime_after(ktime_get(), timeout);
+
+               if (!(sdhci_readb(host, SDHCI_SOFTWARE_RESET) & mask))
+                       break;
+               if (timedout) {
                        pr_err("%s: Reset 0x%x never completed.\n",
                                mmc_hostname(host->mmc), (int)mask);
                        sdhci_dumpregs(host);
@@ -1608,9 +1612,13 @@ void sdhci_enable_clk(struct sdhci_host *host, u16 clk)
 
        /* Wait max 20 ms */
        timeout = ktime_add_ms(ktime_get(), 20);
-       while (!((clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL))
-               & SDHCI_CLOCK_INT_STABLE)) {
-               if (ktime_after(ktime_get(), timeout)) {
+       while (1) {
+               bool timedout = ktime_after(ktime_get(), timeout);
+
+               clk = sdhci_readw(host, SDHCI_CLOCK_CONTROL);
+               if (clk & SDHCI_CLOCK_INT_STABLE)
+                       break;
+               if (timedout) {
                        pr_err("%s: Internal clock never stabilised.\n",
                               mmc_hostname(host->mmc));
                        sdhci_dumpregs(host);
--

2.17.1

author
#12 lore raw

Re: [PATCH V3 rebase] mmc: sdhci: fix the timeout check window for clock and reset

Quoted 3 lines · On Thu, 6 Dec 2018 08:55:04 +0100 Ulf Hansson <[email protected]> wrote:

Could you check at your side and see what can be wrong? If there is too much hazzle I can manually fixup the patch next week, as one time thing.

Sorry for the confusion, I just resent with git send-email to avoid any thing unexpected. Please try again.

Quoted 4 lines

Kind regards
Uffe

maintainer
#13 lore raw
In reply to Du, Alek
Quoted 42 lines · Alek
Quoted 2 lines · On Fri, 30 Nov 2018 16:40:04 +0200 Adrian Hunter <[email protected]>…

So you are saying this only happens under virtualization?

Yes, I saw the issue under ACRN virtualization Service OS (4.19 kernel). But theoretically it can happen in other case when scheduling is not that good. (due to bad driver or other high priority task)

Quoted 10 lines
Quoted 7 lines

Please look at the sdhci_enable_clk() below, there is a window in clock stabilization check. The first check is to check status register, the second check is to check if time passed. That's why I can capture a case that after time passed, the actually clock control register indicated that clock is stable. So the error handling is wrong...

Sure, but "Internal clock never stabilised." is not one of the errors you listed.

Sorry my bad not listing all the error log:

Case 1. clock stabilization timeout: (the below clock control dump shows clock is good)

[159525.255629] mmc1: Internal clock never stabilised.
[159525.255818] mmc1: sdhci: ============ SDHCI REGISTER DUMP ===========
[159525.256049] mmc1: sdhci: Sys addr:  0x00000000 | Version:  0x00001002
[159525.256277] mmc1: sdhci: Blk size:  0x00000000 | Blk cnt:  0x00000000
[159525.256523] mmc1: sdhci: Argument:  0x00000000 | Trn mode: 0x00000000
[159525.256752] mmc1: sdhci: Present:   0x1fff0000 | Host ctl: 0x00000000
[159525.256979] mmc1: sdhci: Power:     0x0000000b | Blk gap:  0x00000080
[159525.257205] mmc1: sdhci: Wake-up:   0x00000000 | Clock:    0x0000fa03

Case 2. Reset timeout: (the same check window in sdhci_reset())

[ 7639.968613] mmc1: Reset 0x4 never completed.

Case 3. Hardware interrupt timeout

[ 1049.561728] mmc1: Timeout waiting for hardware interrupt.
Quoted 2 lines
Quoted 2 lines
Quoted 8 lines
Quoted 4 lines
Quoted 2 lines

Also the sdhci_send_command commands is not in spin lock There is a windows between mod_timer and real command send...

What code path does not have a spin lock?

Ouch my bad, the sdhci_send_command are called either from spinlock or IRQ handler, so this part is good ...

I'll send a new patch to cover case 1 and case 2 if you agree.

Please do the mod_timer case also, but please make it a separate patch. Prior to v4.18 it was essentially a 10-second timer, without a preemptible gap afterwards, so extremely unlikely to timeout prematurely, hence:

Fixes fc1fa1b7db275 ("mmc: sdhci: Program a relatively accurate SW timeout value")
Cc [email protected] # v4.18+