regulator: mt6311: Use linear instead of linear range for mt6311_buck_ops
Subsystems (2)
PATCH 1/1 regulator: mt6311: Use linear instead of linear range for mt6311_buck_ops
Current code already set .min_uV and .uV_step fields and it actually can use regulator_list_voltage_linear.
So remove buck_volt_range and use regulator_list_voltage_linear instead.
Signed-off-by Axel Lin <[email protected]>
--- drivers/regulator/mt6311-regulator.c | 10 ++-------- 1 file changed, 2 insertions(+), 8 deletions(-)
drivers/regulator/mt6311-regulator.c +2 -8
@@ -38,13 +38,9 @@ static const struct regmap_config mt6311_regmap_config = {#define MT6311_MAX_UV 1393750#define MT6311_STEP_UV 6250 -static const struct regulator_linear_range buck_volt_range[] = { -REGULATOR_LINEAR_RANGE (MT6311_MIN_UV ,0 ,0x7f ,MT6311_STEP_UV ), -}; -static const struct regulator_ops mt6311_buck_ops = { - .list_voltage = regulator_list_voltage_linear_range, - .map_voltage = regulator_map_voltage_linear_range, + .list_voltage = regulator_list_voltage_linear, + .map_voltage = regulator_map_voltage_linear, .set_voltage_sel = regulator_set_voltage_sel_regmap, .get_voltage_sel = regulator_get_voltage_sel_regmap, .set_voltage_time_sel = regulator_set_voltage_time_sel,
@@ -71,8 +67,6 @@ static const struct regulator_ops mt6311_ldo_ops = { .min_uV = MT6311_MIN_UV,\ .uV_step = MT6311_STEP_UV,\ .owner = THIS_MODULE,\ - .linear_ranges = buck_volt_range, \ - .n_linear_ranges = ARRAY_SIZE(buck_volt_range), \ .enable_reg = MT6311_VDVFS11_CON9,\ .enable_mask = MT6311_PMIC_VDVFS11_EN_MASK,\ .vsel_reg = MT6311_VDVFS11_CON12,\
Signature · 1 line
2.17.1