Skip to contentSkip to conversation

powerpc/mm: dump block address translation on book3s/32

bug report Dan Carpenter 2 participants 2 messages Feb 22, 2019

lore
Share & tools
lore
#0 lore raw

Hello Christophe Leroy,

The patch 7c91efce1608: "powerpc/mm: dump block address translation on book3s/32" from Dec 3, 2018, leads to the following static checker warning:

	arch/powerpc/mm/dump_bats.c:20 pp_601()
	warn: both sides of ternary the same: '"RWX"'

arch/powerpc/mm/dump_bats.c

    13 static char *pp_601(int k, int pp)
    14 {
    15 	if (pp == 0)
    16 		return k ? "NA" : "RWX";
    17 	if (pp == 1)
    18 		return k ? "ROX" : "RWX";
    19 	if (pp == 2)
--> 20 		return k ? "RWX" : "RWX";
                            ^^^     ^^^
    21 	return k ? "ROX" : "ROX";
                    ^^^     ^^^

Was something else intended here? Or we could make it simpler:

	if (pp == 2)
		return "RWX";
	return "ROX";


    22 }

regards,
dan carpenter

#1 lore raw

Hello Dan,

Le 22/02/2019 à 11:43, Dan Carpenter a écrit :

Quoted 22 lines

Hello Christophe Leroy,

The patch 7c91efce1608: "powerpc/mm: dump block address translation on book3s/32" from Dec 3, 2018, leads to the following static checker warning:

	arch/powerpc/mm/dump_bats.c:20 pp_601()
	warn: both sides of ternary the same: '"RWX"'

arch/powerpc/mm/dump_bats.c

     13 static char *pp_601(int k, int pp)
     14 {
     15 	if (pp == 0)
     16 		return k ? "NA" : "RWX";
     17 	if (pp == 1)
     18 		return k ? "ROX" : "RWX";
     19 	if (pp == 2)
--> 20 		return k ? "RWX" : "RWX";
                             ^^^     ^^^
     21 	return k ? "ROX" : "ROX";
                     ^^^     ^^^
Quoted 9 lines

Was something else intended here? Or we could make it simpler:

	if (pp == 2)
		return "RWX";
	return "ROX";


     22 }

The intention was to map the following table from the mpc601 user manual chapter 6.4:

Table 6-7. Access Protection Control with Key

Key(1)  PP(2)  Block or Page Type
0       00     Read/write
0       01     Read/write
0       10     Read/write
0       11     Read only
1       00     No access
1       01     Read only
1       10     Read/write
1       11     Read only

(1) Ks or Ku selected by state of MSR[PR]
(2) PP protection option bits in BAT array entry or PTE

So I have no objection for your proposed change

Regards
Christophe