Documentation/watchdog: Add documentation mlx-wdt driver
Subsystems (2)
PATCH v5 1/1 Documentation/watchdog: Add documentation mlx-wdt driver
From: Michael Shych <[email protected]>
Add documentation with details of Mellanox watchdog driver.
Signed-off-by Michael Shych <[email protected]>
---v1->v4
1. Remove sentence that now doesn't correspond to code.
2. Add explanations about nowayout and start_at_boot options.
---v5->v4
Fix typo in nowayout explanation.
--- Documentation/watchdog/mlx-wdt.txt | 52 ++++++++++++++++++++++++++++++++++++++ 1 file changed, 52 insertions(+) create mode 100644 Documentation/watchdog/mlx-wdt.txt
Documentation/watchdog/mlx-wdt.txt new file +52 -0
@@ -0,0 +1,52 @@ + Mellanox watchdog drivers + for x86 based system switches + +This driver provides watchdog functionality for various Mellanox +Ethernet and Infiniband switch systems. + +Mellanox watchdog device is implemented in a programmable logic device. + +There are 2 types of HW watchdog implementations. + +Type 1: +Actual HW timeout can be defined as a power of 2 msec. +e.g. timeout 20 sec will be rounded up to 32768 msec. +The maximum timeout period is 32 sec (32768 msec.), +Get time-left isn't supported + +Type 2: +Actual HW timeout is defined in sec. and it's the same as +a user-defined timeout. +Maximum timeout is 255 sec. +Get time-left is supported. + +Type 1 HW watchdog implementation exist in old systems and +all new systems have type 2 HW watchdog. +Two types of HW implementation have also different register map. + +Mellanox system can have 2 watchdogs: main and auxiliary. +Main and auxiliary watchdog devices can be enabled together +on the same system. +There are several actions that can be defined in the watchdog: +system reset, start fans on full speed and increase register counter. +The last 2 actions are performed without a system reset. +Actions without reset are provided for auxiliary watchdog device, +which is optional. +Watchdog can be started during a probe, in this case it will be +pinged by watchdog core before watchdog device will be opened by +user space application. +Watchdog can be initialised in nowayout way, i.e. oncse started +it can't be stopped. + +This mlx-wdt driver supports both HW watchdog implementations. + +Watchdog driver is probed from the common mlx_platform driver. +Mlx_platform driver provides an appropriate set of registers for +Mellanox watchdog device, identity name (mlx-wdt-main or mlx-wdt-aux), +initial timeout, performed action in expiration and configuration flags. +watchdog configuration flags: nowayout and start_at_boot, hw watchdog +version - type1 or type2. +The driver checks during initialization if the previous system reset +was done by the watchdog. If yes, it makes a notification about this event. + +Access to HW registers is performed through a generic regmap interface.
Signature · 1 line
2.11.0
Quoted 5 lines · On 2/24/19 9:26 AM, [email protected] wrote:
From: Michael Shych <[email protected]>
Add documentation with details of Mellanox watchdog driver.
Signed-off-by Michael Shych <[email protected]>
Reviewed-by Guenter Roeck <[email protected]>
Quoted 71 lines
---
v1->v4
1. Remove sentence that now doesn't correspond to code.
2. Add explanations about nowayout andstart_at_bootoptions.
---v5->v4
Fix typo in nowayout explanation.--- Documentation/watchdog/mlx-wdt.txt | 52 ++++++++++++++++++++++++++++++++++++++ 1 file changed, 52 insertions(+)create mode 100644
Documentation/watchdog/mlx-wdt.txtDocumentation/watchdog/mlx-wdt.txt new file +52
-0@@ -0,0 +1,52 @@ + Mellanox watchdog drivers + for x86 based system switches + +This driver provides watchdog functionality for various Mellanox +Ethernet and Infiniband switch systems. + +Mellanox watchdog device is implemented in a programmable logic device. + +There are 2 types of HW watchdog implementations. + +Type 1: +Actual HW timeout can be defined as a power of 2 msec. +e.g. timeout 20 sec will be rounded up to 32768 msec. +The maximum timeout period is 32 sec (32768 msec.), +Get time-left isn't supported + +Type 2: +Actual HW timeout is defined in sec. and it's the same as +a user-defined timeout. +Maximum timeout is 255 sec. +Get time-left is supported. + +Type 1 HW watchdog implementation exist in old systems and +all new systems have type 2 HW watchdog. +Two types of HW implementation have also different register map. + +Mellanox system can have 2 watchdogs: main and auxiliary. +Main and auxiliary watchdog devices can be enabled together +on the same system. +There are several actions that can be defined in the watchdog: +system reset, start fans on full speed and increase register counter. +The last 2 actions are performed without a system reset. +Actions without reset are provided for auxiliary watchdog device, +which is optional. +Watchdog can be started during a probe, in this case it will be +pinged by watchdog core before watchdog device will be opened by +user space application. +Watchdog can be initialised in nowayout way, i.e. oncse started +it can't be stopped. + +This mlx-wdt driver supports both HW watchdog implementations. + +Watchdog driver is probed from the common mlx_platform driver. +Mlx_platform driver provides an appropriate set of registers for +Mellanox watchdog device, identity name (mlx-wdt-main or mlx-wdt-aux), +initial timeout, performed action in expiration and configuration flags. +watchdog configuration flags: nowayout and start_at_boot, hw watchdog +version - type1 or type2. +The driver checks during initialization if the previous system reset +was done by the watchdog. If yes, it makes a notification about this event. + +Access to HW registers is performed through a generic regmap interface.