arm64: dts: renesas: r8a77995: draak: Enable CAN0, CAN1
Subsystems (2)
PATCH 1/1 arm64: dts: renesas: r8a77995: draak: Enable CAN0, CAN1
From: Marek Vasut <[email protected]>
Enable both CAN0 and CAN1 controllers on R8A77995 Draak board, since they are available on connectors CN43, CN44 respectively.
--- .../arm64/boot/dts/renesas/r8a77995-draak.dts | 22 +++++++++++++++++++ 1 file changed, 22 insertions(+)
arch/arm64/boot/dts/renesas/r8a77995-draak.dts +22 -0
@@ -179,6 +179,18 @@ }; }; +&can0 { + pinctrl-0 = <&can0_pins>; + pinctrl-names = "default"; + status = "okay"; +}; + +&can1 { + pinctrl-0 = <&can1_pins>; + pinctrl-names = "default"; + status = "okay"; +}; + &du { pinctrl-0 = <&du_pins>; pinctrl-names = "default";
@@ -375,6 +387,16 @@ }; }; + can0_pins: can0 { + groups = "can0_data_a"; + function = "can0"; + }; + + can1_pins: can1 { + groups = "can1_data_a"; + function = "can1"; + }; + du_pins: du { groups = "du_rgb888", "du_sync", "du_disp", "du_clk_out_0"; function = "du";
Signature · 1 line
2.20.1
Hi Marek,
Quoted 6 lines · On Sat, Mar 9, 2019 at 3:06 AM <[email protected]> wrote:
From: Marek Vasut <[email protected]>
Enable both CAN0 and CAN1 controllers on R8A77995 Draak board, since they are available on connectors CN43, CN44 respectively.
Signed-off-by Marek Vasut <[email protected]>
Thanks for your patch!
I assume you have tested this with your CAN-analyzer?
Gr{oetje,eeting}s,
Geert
Signature · 5 lines
Geert Uytterhoeven -- There's lots of Linux beyond ia32 -- [email protected] In personal conversations with technical people, I call myself a hacker. But when I'm talking to journalists I just say "programmer" or something like that. -- Linus Torvalds
Quoted 5 lines · Geert Uytterhoeven
Hi Marek,
Quoted 2 lines · On Sat, Mar 9, 2019 at 3:06 AM <[email protected]> wrote:
From: Marek Vasut <[email protected]>
Quoted 7 lines
Quoted 4 lines
Enable both CAN0 and CAN1 controllers on R8A77995 Draak board, since they are available on connectors CN43, CN44 respectively.
Signed-off-by Marek Vasut <[email protected]>Thanks for your patch!
I assume you have tested this with your CAN-analyzer?
Nope, only remotely between two CAN ports thus far.
Signature · 2 lines
Best regards, Marek Vasut
Simon Horman
AppliedQuoted 9 lines · Marek Vasut
Quoted 8 lines · Geert Uytterhoeven
Hi Marek,
Quoted 5 lines · On Sat, Mar 9, 2019 at 3:06 AM <[email protected]> wrote:
From: Marek Vasut <[email protected]>
Enable both CAN0 and CAN1 controllers on R8A77995 Draak board, since they are available on connectors CN43, CN44 respectively.
Quoted 6 lines
Quoted 4 lines
Quoted 1 line
Signed-off-by Marek Vasut <[email protected]>Thanks for your patch!
I assume you have tested this with your CAN-analyzer?Nope, only remotely between two CAN ports thus far.
Thanks, applied for v5.2.