Skip to contentSkip to conversation

nvme-cli: add missing endianness conversions for telemetry log page

PATCH New Akinobu Mita 2 participants 2 messages May 5, 2019 – May 6, 2019 NVMe

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 nvme-cli: add missing endianness conversions for telemetry log page

Add missing endianness conversions for data area last block fields of telemetry log page.

Cc Keith Busch <keith.busch at intel.com>
Cc Jens Axboe <axboe at fb.com>
Cc Christoph Hellwig <hch at lst.de>
Cc Sagi Grimberg <sagi at grimberg.me>
Signed-off-by Akinobu Mita <akinobu.mita at gmail.com>
---
 linux/nvme.h | 6 +++---
 nvme.c       | 6 +++---
 2 files changed, 6 insertions(+), 6 deletions(-)
linux/nvme.h +3 -3
index a1422a7..f6d7341 100644
@@ -433,9 +433,9 @@ struct nvme_telemetry_log_page_hdr {
 	__u8    lpi; /* Log page identifier */
 	__u8    rsvd[4];
 	__u8    iee_oui[3];
-	__u16   dalb1; /* Data area 1 last block */
-	__u16   dalb2; /* Data area 2 last block */
-	__u16   dalb3; /* Data area 3 last block */
+	__le16  dalb1; /* Data area 1 last block */
+	__le16  dalb2; /* Data area 2 last block */
+	__le16  dalb3; /* Data area 3 last block */
 	__u8    rsvd1[368]; /* TODO verify */
 	__u8    ctrlavail; /* Controller initiated data avail?*/
 	__u8    ctrldgn; /* Controller initiated telemetry Data Gen # */
nvme.c +3 -3
index f4c027b..220fb18 100644
@@ -376,13 +376,13 @@ static int get_telemetry_log(int argc, char **argv, struct command *cmd, struct
 
 	switch (cfg.data_area) {
 	case 1:
-		full_size = (hdr->dalb1 * bs) + offset;
+		full_size = (le16_to_cpu(hdr->dalb1) * bs) + offset;
 		break;
 	case 2:
-		full_size = (hdr->dalb2 * bs) + offset;
+		full_size = (le16_to_cpu(hdr->dalb2) * bs) + offset;
 		break;
 	case 3:
-		full_size = (hdr->dalb3 * bs) + offset;
+		full_size = (le16_to_cpu(hdr->dalb3) * bs) + offset;
 		break;
 	default:
 		fprintf(stderr, "Invalid data area requested");
Signature · 1 line
2.7.4
maintainer Applied
#1 lore raw

PATCH 1/1 nvme-cli: add missing endianness conversions for telemetry log page

Quoted 2 lines · Akinobu Mita

Add missing endianness conversions for data area last block fields of telemetry log page.

Applied, thank you.