numa: improve cpu hotplug error message with a wrong node-id
PATCH v4 1/1 numa: improve cpu hotplug error message with a wrong node-id
On pseries, core-ids are strongly binded to a node-id by the command line option. If an user tries to add a CPU to the wrong node, he has an error but it is not really helpful:
qemu-system-ppc64 ... -smp 1,maxcpus=64,cores=1,threads=1,sockets=1 \
-numa node,nodeid=0 -numa node,nodeid=1 ... (qemu) device_add power9_v2.0-spapr-cpu-core,core-id=30,node-id=1
Error: node-id=1 must match numa node specified with -numa option
This patch improves this error message by giving to the user the good node-id to use with the core-id he's providing
Error: invalid node-id, must be 0
---
Notes:
v4: simplify the message
v3: only add the topology to the existing message
As suggested by Igor replace
Error: core-id 30 can only be plugged into node-id 0
by
Error: node-id=1 must match numa node specified with -numa option 'node-id 0'
v2: display full topology in the error message
numa.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
numa.c +2 -2
@@ -470,8 +470,8 @@ void numa_cpu_pre_plug(const CPUArchId *slot, DeviceState *dev, Error **errp) "node-id", errp); } }else if (node_id != slot->props.node_id) { -error_setg (errp,"node-id=%d must match numa node specified " -"with -numa option" , node_id); +error_setg (errp,"invalid node-id, must be %" PRId64, + slot->props.node_id); } }
Signature · 1 line
2.20.1
Quoted 10 lines · On Wed, 29 May 2019 18:07:47 +0200 Laurent Vivier <[email protected]> wrote:
On pseries, core-ids are strongly binded to a node-id by the command line option. If an user tries to add a CPU to the wrong node, he has an error but it is not really helpful:
qemu-system-ppc64 ... -smp 1,maxcpus=64,cores=1,threads=1,sockets=1 \ -numa node,nodeid=0 -numa node,nodeid=1 ...(qemu)
device_addpower9_v2.0-spapr-cpu-core,core-id=30,node-id=1
Error: node-id=1 must match numa node specified with -numa option
Quoted 6 lines
This patch improves this error message by giving to the user the good node-id to use with the core-id he's providing
Error: invalid node-id, must be 0
Signed-off-by Laurent Vivier <[email protected]>
Quoted 31 lines
---
Notes:
v4: simplify the messagev3: only add the topology to the existing message
As suggested by Igor replace
Error: core-id 30 can only be plugged into node-id 0
by
Error: node-id=1 must match numa node specified with -numa option 'node-id 0'v2: display full topology in the error message
numa.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)numa.c +2
-2@@ -470,8 +470,8 @@ void numa_cpu_pre_plug(const CPUArchId *slot, DeviceState *dev, Error **errp) "node-id", errp); } }else if (node_id != slot->props.node_id) { -error_setg (errp,"node-id=%d must match numa node specified " -"with -numa option" , node_id); +error_setg (errp,"invalid node-id, must be %" PRId64, + slot->props.node_id); } }
Eduardo Habkost
AppliedQuoted 10 lines · Laurent Vivier
On pseries, core-ids are strongly binded to a node-id by the command line option. If an user tries to add a CPU to the wrong node, he has an error but it is not really helpful:
qemu-system-ppc64 ... -smp 1,maxcpus=64,cores=1,threads=1,sockets=1 \ -numa node,nodeid=0 -numa node,nodeid=1 ...(qemu)
device_addpower9_v2.0-spapr-cpu-core,core-id=30,node-id=1
Error: node-id=1 must match numa node specified with -numa option
Quoted 6 lines
This patch improves this error message by giving to the user the good node-id to use with the core-id he's providing
Error: invalid node-id, must be 0
Signed-off-by Laurent Vivier <[email protected]>
Queued, thanks.
Signature · 1 line
Eduardo