Skip to contentSkip to conversation

i.MX7ULP: Fix system reset after a7 rtc alarm expired.

PATCH RESEND New sbabic at denx.de 1 participant 1 message Aug 5, 2019

lore
Share & tools
lore
#0 lore raw

PATCH RESEND 3/14 i.MX7ULP: Fix system reset after a7 rtc alarm expired.

Quoted 8 lines

From: Bai Ping <[email protected]>
The board will reboot if A7 core enter mem mode by rtc, then M4 core enter VLLS mode after the RTC alarm expired. Enable the dumb PMIC mode to fix this issue.
Since i.MX7ULP B0 moves the SNVS LP into M4 domain, A core can't access it. So check the CPU rev and not apply the settings for B0.

Applied to u-boot-imx, master, thanks !

Best regards,
Stefano Babic

Signature · 5 lines
=====================================================================
DENX Software Engineering GmbH,      Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: sbabic at denx.de
=====================================================================