net/ice: add flow mark hint support
PATCH v4 1/1 net/ice: add flow mark hint support
Since not all data paths support flow mark, the driver needs a hint from application to select the correct data path if flow mark is required. The patch introduces a devarg "flow-mark-support" as a workaround solution, since a standard way is still ongoing.
---
v4:
- remove debug code, fix typos
v3:
- add "experimental notification" in ice.rst
v2:
- fix typos
doc/guides/nics/ice.rst | 12 ++++++++++++ drivers/net/ice/ice_ethdev.c | 12 +++++++++++- drivers/net/ice/ice_ethdev.h | 1 + drivers/net/ice/ice_rxtx_vec_common.h | 6 ++++++ 4 files changed, 30 insertions(+), 1 deletion(-)
doc/guides/nics/ice.rst +12 -0
@@ -98,6 +98,18 @@ Runtime Config Options -w 80:00.0,pipeline-mode-support=1 +- ``Flow Mark Support`` (default ``0``) + + This is a hint to the driver to select the data path that supports flow mark extraction + by default. + NOTE: This is an experimental devarg, it will be removed when any of below conditions + is ready. + 1) all data paths support flow mark (currently vPMD does not) + 2) a new offload like RTE_DEV_RX_OFFLOAD_FLOW_MARK be introduced as a standard way to hint. + Example:: + + -w 80:00.0,flow-mark-support=1 + - ``Protocol extraction for per queue`` Configure the RX queues to do protocol extraction into mbuf for protocol
drivers/net/ice/ice_ethdev.c +11 -1
@@ -23,11 +23,13 @@/* devargs */ #define ICE_SAFE_MODE_SUPPORT_ARG "safe-mode-support"#define ICE_PIPELINE_MODE_SUPPORT_ARG "pipeline-mode-support" +#define ICE_FLOW_MARK_SUPPORT_ARG "flow-mark-support"#define ICE_PROTO_XTR_ARG "proto_xtr"static const char *const ice_valid_args[] = {ICE_SAFE_MODE_SUPPORT_ARG ,ICE_PIPELINE_MODE_SUPPORT_ARG , +ICE_FLOW_MARK_SUPPORT_ARG ,ICE_PROTO_XTR_ARG ,NULL };
@@ -1987,6 +1989,13 @@ static int ice_parse_devargs(struct rte_eth_dev *dev) ret =rte_kvargs_process (kvlist,ICE_PIPELINE_MODE_SUPPORT_ARG , &parse_bool, &ad->devargs.pipe_mode_support); +if (ret) + goto bail; + + ret =rte_kvargs_process (kvlist,ICE_FLOW_MARK_SUPPORT_ARG , + &parse_bool, &ad->devargs.flow_mark_support); +if (ret) + goto bail; bail:rte_kvargs_free (kvlist);
@@ -4562,7 +4571,8 @@ RTE_PMD_REGISTER_KMOD_DEP(net_ice, "* igb_uio | uio_pci_generic | vfio-pci");RTE_PMD_REGISTER_PARAM_STRING (net_ice,ICE_PROTO_XTR_ARG "=[queue:]<vlan|ipv4|ipv6|ipv6_flow|tcp>" ICE_SAFE_MODE_SUPPORT_ARG "=<0|1>" -ICE_PIPELINE_MODE_SUPPORT_ARG "=<0|1>" ); +ICE_PIPELINE_MODE_SUPPORT_ARG "=<0|1>" +ICE_FLOW_MARK_SUPPORT_ARG "=<0|1>" );RTE_INIT (ice_init_log) {
drivers/net/ice/ice_ethdev.h +1 -0
@@ -391,6 +391,7 @@ struct ice_devargs {int safe_mode_support;uint8_t proto_xtr_dflt;int pipe_mode_support; +int flow_mark_support;uint8_t proto_xtr[ICE_MAX_QUEUE_NUM ]; };
drivers/net/ice/ice_rxtx_vec_common.h +6 -0
@@ -268,6 +268,12 @@ ice_rx_vec_dev_check_default(struct rte_eth_dev *dev) {int i;struct ice_rx_queue *rxq; +struct ice_adapter *ad = +ICE_DEV_PRIVATE_TO_ADAPTER (dev->data->dev_private); + +/* vPMD does not support flow mark. */ +if (ad->devargs.flow_mark_support) +return -1 ;for (i =0 ; i < dev->data->nb_rx_queues; i++) { rxq = dev->data->rx_queues[i];
Signature · 1 line
2.13.6
Ye Xiaolong
AppliedQuoted 122 lines · Qi Zhang
Since not all data paths support flow mark, the driver needs a hint from application to select the correct data path if flow mark is required. The patch introduces a devarg "flow-mark-support" as a workaround solution, since a standard way is still ongoing.
Signed-off-by Qi Zhang <[email protected]>Acked-by Qiming Yang <[email protected]>---
v4:
- remove debug code, fix typosv3:
- add "experimental notification" inice.rstv2:
- fix typosdoc/guides/nics/ice.rst | 12 ++++++++++++ drivers/net/ice/ice_ethdev.c | 12 +++++++++++- drivers/net/ice/ice_ethdev.h | 1 + drivers/net/ice/ice_rxtx_vec_common.h | 6 ++++++ 4 files changed, 30 insertions(+), 1 deletion(-)doc/guides/nics/ice.rst +12
-1@@ -98,6 +98,18 @@ Runtime Config Options -w 80:00.0,pipeline-mode-support=1 +- ``Flow Mark Support`` (default ``0``) + + This is a hint to the driver to select the data path that supports flow mark extraction + by default. + NOTE: This is an experimental devarg, it will be removed when any of below conditions + is ready. + 1) all data paths support flow mark (currently vPMD does not) + 2) a new offload like RTE_DEV_RX_OFFLOAD_FLOW_MARK be introduced as a standard way to hint. + Example:: + + -w 80:00.0,flow-mark-support=1 + - ``Protocol extraction for per queue`` Configure the RX queues to do protocol extraction into mbuf for protocoldrivers/net/ice/ice_ethdev.c +9
-0@@ -23,11 +23,13 @@/* devargs */ #define ICE_SAFE_MODE_SUPPORT_ARG "safe-mode-support"#define ICE_PIPELINE_MODE_SUPPORT_ARG "pipeline-mode-support" +#define ICE_FLOW_MARK_SUPPORT_ARG "flow-mark-support"#define ICE_PROTO_XTR_ARG "proto_xtr"static const char *const ice_valid_args[] = {ICE_SAFE_MODE_SUPPORT_ARG ,ICE_PIPELINE_MODE_SUPPORT_ARG , +ICE_FLOW_MARK_SUPPORT_ARG ,ICE_PROTO_XTR_ARG ,NULL };@@ -1987,6 +1989,13 @@ static int ice_parse_devargs(struct rte_eth_dev *dev) ret =rte_kvargs_process (kvlist,ICE_PIPELINE_MODE_SUPPORT_ARG , &parse_bool, &ad->devargs.pipe_mode_support); +if (ret) + goto bail; + + ret =rte_kvargs_process (kvlist,ICE_FLOW_MARK_SUPPORT_ARG , + &parse_bool, &ad->devargs.flow_mark_support); +if (ret) + goto bail;bail:
rte_kvargs_free(kvlist);drivers/net/ice/ice_ethdev.c +2
-1@@ -4562,7 +4571,8 @@ RTE_PMD_REGISTER_KMOD_DEP(net_ice, "* igb_uio | uio_pci_generic | vfio-pci");RTE_PMD_REGISTER_PARAM_STRING (net_ice,ICE_PROTO_XTR_ARG "=[queue:]<vlan|ipv4|ipv6|ipv6_flow|tcp>" ICE_SAFE_MODE_SUPPORT_ARG "=<0|1>" -ICE_PIPELINE_MODE_SUPPORT_ARG "=<0|1>" ); +ICE_PIPELINE_MODE_SUPPORT_ARG "=<0|1>" +ICE_FLOW_MARK_SUPPORT_ARG "=<0|1>" );RTE_INIT (ice_init_log) {drivers/net/ice/ice_ethdev.h +1
-0@@ -391,6 +391,7 @@ struct ice_devargs {int safe_mode_support;uint8_t proto_xtr_dflt;int pipe_mode_support; +int flow_mark_support;uint8_t proto_xtr[ICE_MAX_QUEUE_NUM ]; };drivers/net/ice/ice_rxtx_vec_common.h +6
-0@@ -268,6 +268,12 @@ ice_rx_vec_dev_check_default(struct rte_eth_dev *dev) {int i;struct ice_rx_queue *rxq; +struct ice_adapter *ad = +ICE_DEV_PRIVATE_TO_ADAPTER (dev->data->dev_private); + +/* vPMD does not support flow mark. */ +if (ad->devargs.flow_mark_support) +return -1 ;for (i =0 ; i < dev->data->nb_rx_queues; i++) { rxq = dev->data->rx_queues[i];Signature · 1 line
2.13.6
Applied to dpdk-next-net-intel, Thanks.
19/11/2019 07:14, Qi Zhang:
Quoted 10 lines
Since not all data paths support flow mark, the driver needs a hint from application to select the correct data path if flow mark is required. The patch introduces a devarg "flow-mark-support" as a workaround solution, since a standard way is still ongoing.
Signed-off-by Qi Zhang <[email protected]>Acked-by Qiming Yang <[email protected]>---
Quoted 8 lines
v4:
- remove debug code, fix typosv3:
- add "experimental notification" inice.rstv2:
- fix typos
Please use --in-reply-to to help tracking all the versions together.
doc/guides/nics/ice.rst Runtime Config Options · line 108
Quoted 8 lines
+- ``Flow Mark Support`` (default ``0``)
doc/guides/nics/ice.rst +7
-0+ + This is a hint to the driver to select the data path that supports flow mark extraction + by default. + NOTE: This is an experimental devarg, it will be removed when any of below conditions + is ready. + 1) all data paths support flow mark (currently vPMD does not) + 2) a new offload like RTE_DEV_RX_OFFLOAD_FLOW_MARK be introduced as a standard way to hint.
When the data path is selected?
I suppose such decision should be done when starting the port, after everything is configured.
So you can check if a rte_flow rule was added for mark action. Why the user needs to use an explicit option?
Quoted 39 lines
-----Original Message-----
From: Thomas Monjalon <[email protected]>
Sent: Thursday, November 21, 2019 2:57 AM
To: Zhang, Qi Z <[email protected]>
Cc: [email protected]; Ye, Xiaolong <[email protected]>; Yigit, Ferruh <[email protected]>; [email protected]; [email protected]
Subject: Re: [dpdk-dev] [PATCH v4] net/ice: add flow mark hint support19/11/2019 07:14, Qi Zhang:
Quoted 9 lines
Since not all data paths support flow mark, the driver needs a hint from application to select the correct data path if flow mark is required. The patch introduces a devarg "flow-mark-support" as a workaround solution, since a standard way is still ongoing.
Signed-off-by Qi Zhang <[email protected]>Acked-by Qiming Yang <[email protected]>---
Quoted 8 lines
v4:
- remove debug code, fix typosv3:
- add "experimental notification" inice.rstv2:
- fix typosPlease use --in-reply-to to help tracking all the versions together.
Review
Quoted 8 lines
+- ``Flow Mark Support`` (default ``0``)
(quoted diff) +7
-0+ + This is a hint to the driver to select the data path that supports + flow mark extraction by default. + NOTE: This is an experimental devarg, it will be removed when any + of below conditions is ready. + 1) all data paths support flow mark (currently vPMD does not) + 2) a new offload like RTE_DEV_RX_OFFLOAD_FLOW_MARK be introduced
Quoted 3 lines
as a standard way to hint.
When the data path is selected?
dev_start
Quoted 4 lines
I suppose such decision should be done when starting the port, after everything is configured.
So you can check if arte_flowrule was added for mark action.
Why the user needs to use an explicit option?
A rte_flow with mark can be issued at any time after dev_start when it is need, in that case, we have to reject the flow, this has been complained a lot base on previous feedback by users, since inconsistent behavior (sometimes mark works, some time it does not) is not expected Also this option is overwhelmed by option 1 if we plan to do a clean fix in driver.
Quoted 1 line
21/11/2019 02:19, Zhang, Qi Z:
Quoted 22 lines
From: Thomas Monjalon <[email protected]>
Quoted 17 lines
19/11/2019 07:14, Qi Zhang:
Quoted 9 lines
Since not all data paths support flow mark, the driver needs a hint from application to select the correct data path if flow mark is required. The patch introduces a devarg "flow-mark-support" as a workaround solution, since a standard way is still ongoing.
Signed-off-by Qi Zhang <[email protected]>Acked-by Qiming Yang <[email protected]>---
+- ``Flow Mark Support`` (default ``0``)Review
Quoted 7 lines
(quoted diff) +7
-0+ + This is a hint to the driver to select the data path that supports + flow mark extraction by default. + NOTE: This is an experimental devarg, it will be removed when any + of below conditions is ready. + 1) all data paths support flow mark (currently vPMD does not) + 2) a new offload like RTE_DEV_RX_OFFLOAD_FLOW_MARK be introducedQuoted 3 lines
as a standard way to hint.
When the data path is selected?
Quoted 8 lines
dev_startQuoted 4 lines
I suppose such decision should be done when starting the port, after everything is configured.
So you can check if arte_flowrule was added for mark action.
Why the user needs to use an explicit option?A
rte_flowwith mark can be issued at any time afterdev_startwhen it is need, in that case, we have to reject the flow, this has been complained a lot base on previous feedback by users, since inconsistent behavior (sometimes mark works, some time it does not) is not expected
OK so you confirm the problem is only when a configuration is changed at runtime without stopping the port.
Quoted 1 line
Also this option is overwhelmed by option 1 if we plan to do a clean fix in driver.
You want the application (or the user) to announce in advance which configuration could be applied during the runtime.
I think we should consider the problem for any runtime configuration. We never clearly defined which configuration is allowed at runtime.
Which other configs may be setup at runtime? MTU? VLAN? mirroring? tunneling checksum? promiscuous? supported packet types? IEEE1588?
Quoted 53 lines
-----Original Message-----
From: Thomas Monjalon <[email protected]>
Sent: Thursday, November 21, 2019 3:37 PM
To: Zhang, Qi Z <[email protected]>
Cc: [email protected]; Ye, Xiaolong <[email protected]>; Yigit, Ferruh <[email protected]>; [email protected]; [email protected]
Subject: Re: [dpdk-dev] [PATCH v4] net/ice: add flow mark hint support21/11/2019 02:19, Zhang, Qi Z:
Quoted 30 lines
From: Thomas Monjalon <[email protected]>
Quoted 18 lines
19/11/2019 07:14, Qi Zhang:
Quoted 9 lines
Since not all data paths support flow mark, the driver needs a hint from application to select the correct data path if flow mark is required. The patch introduces a devarg "flow-mark-support" as a workaround solution, since a standard way is still ongoing.
Signed-off-by Qi Zhang <[email protected]>Acked-by Qiming Yang <[email protected]>---
+- ``Flow Mark Support`` (default ``0``)Review
Quoted 8 lines
(quoted diff) +8
-0+ + This is a hint to the driver to select the data path that + supports flow mark extraction by default. + NOTE: This is an experimental devarg, it will be removed when + any of below conditions is ready. + 1) all data paths support flow mark (currently vPMD does not) + 2) a new offload like RTE_DEV_RX_OFFLOAD_FLOW_MARK be + introducedQuoted 3 lines
as a standard way to hint.
When the data path is selected?
dev_startQuoted 4 lines
I suppose such decision should be done when starting the port, after everything is configured.
So you can check if arte_flowrule was added for mark action. Why the user needs to use an explicit option?Quoted 5 lines
A
rte_flowwith mark can be issued at any time afterdev_startwhen it is need, in that case, we have to reject the flow, this has been complained a lot base on previous feedback by users, since inconsistent behavior (sometimes mark works, some time it does not) is not expectedOK so you confirm the problem is only when a configuration is changed at runtime without stopping the port.
Quoted 1 line
Also this option is overwhelmed by option 1 if we plan to do a clean fix in
driver.
Quoted 7 lines
You want the application (or the user) to announce in advance which configuration could be applied during the runtime.
I think we should consider the problem for any runtime configuration. We never clearly defined which configuration is allowed at runtime.Which other configs may be setup at runtime? MTU? VLAN? mirroring? tunneling checksum? promiscuous? supported packet types? IEEE1588?
So far, in rte_eth API, we do dev_started check at dev_configure, queue_setup (if runtime queue setup is not supported by PMD).
All other control path API is case by case depends on hardware capability.
Take i40e as an example; we have to stop the port when setting MTU because we have to reconfigure the hardware queue context, which needs to stop queue that impacts data path. While for VLAN / promiscuous, since it is the case that a rule is added into the on-chip memory, so no need to stop the data path.
Maybe it's a good idea to define a rule that which control path is allowed at runtime, which should not be. But at least I think it's not necessary to prevent users from doing flow configure at runtime.;
Quoted 1 line
21/11/2019 13:40, Zhang, Qi Z:
Quoted 52 lines
From: Thomas Monjalon <[email protected]>
Quoted 43 lines
21/11/2019 02:19, Zhang, Qi Z:
Quoted 30 lines
From: Thomas Monjalon <[email protected]>
Quoted 18 lines
19/11/2019 07:14, Qi Zhang:
Quoted 9 lines
Since not all data paths support flow mark, the driver needs a hint from application to select the correct data path if flow mark is required. The patch introduces a devarg "flow-mark-support" as a workaround solution, since a standard way is still ongoing.
Signed-off-by Qi Zhang <[email protected]>Acked-by Qiming Yang <[email protected]>---
+- ``Flow Mark Support`` (default ``0``)Review
Quoted 8 lines
(quoted diff) +8
-0+ + This is a hint to the driver to select the data path that + supports flow mark extraction by default. + NOTE: This is an experimental devarg, it will be removed when + any of below conditions is ready. + 1) all data paths support flow mark (currently vPMD does not) + 2) a new offload like RTE_DEV_RX_OFFLOAD_FLOW_MARK be + introducedQuoted 3 lines
as a standard way to hint.
When the data path is selected?
dev_startQuoted 4 lines
I suppose such decision should be done when starting the port, after everything is configured.
So you can check if arte_flowrule was added for mark action. Why the user needs to use an explicit option?Quoted 5 lines
A
rte_flowwith mark can be issued at any time afterdev_startwhen it is need, in that case, we have to reject the flow, this has been complained a lot base on previous feedback by users, since inconsistent behavior (sometimes mark works, some time it does not) is not expectedOK so you confirm the problem is only when a configuration is changed at runtime without stopping the port.
Quoted 1 line
Also this option is overwhelmed by option 1 if we plan to do a clean fix in
driver.
Quoted 7 lines
You want the application (or the user) to announce in advance which configuration could be applied during the runtime.
I think we should consider the problem for any runtime configuration. We never clearly defined which configuration is allowed at runtime.Which other configs may be setup at runtime? MTU? VLAN? mirroring? tunneling checksum? promiscuous? supported packet types? IEEE1588?
Quoted 7 lines
So far, in
rte_ethAPI, we dodev_startedcheck atdev_configure,queue_setup(if runtime queue setup is not supported by PMD).
All other control path API is case by case depends on hardware capability.
Take i40e as an example; we have to stop the port when setting MTU because we have to reconfigure the hardware queue context, which needs to stop queue that impacts data path. While for VLAN / promiscuous, since it is the case that a rule is added into the on-chip memory, so no need to stop the data path.Maybe it's a good idea to define a rule that which control path is allowed at runtime, which should not be. But at least I think it's not necessary to prevent users from doing flow configure at runtime.;
Yes I agree.
Based on the list of allowed runtime config changes,
we could think about a global solution to allow datapath optimization taking application needs into account.