Skip to contentSkip to conversation

e1000e: Add support for Alder Lake

PATCH Superseded Sasha Neftin 3 participants 3 messages Jan 19, 2020

Subsystems (2)

v2 of 3 Superseded Latest is v3 →

lore
Share & tools
lore
#0 lore raw

PATCH v2 1/1 e1000e: Add support for Alder Lake

Add devices ID's for the next LOM generations that will be available on the next Intel Client platform (Alder Lake) This patch provides the initial support for these devices

v1->v2:
Address comminuty comments

---
 drivers/net/ethernet/intel/e1000e/ethtool.c | 3 ++-
 drivers/net/ethernet/intel/e1000e/hw.h      | 5 +++++
 drivers/net/ethernet/intel/e1000e/ich8lan.c | 7 +++++++
 drivers/net/ethernet/intel/e1000e/netdev.c  | 7 ++++++-
 drivers/net/ethernet/intel/e1000e/ptp.c     | 1 +
 5 files changed, 21 insertions(+), 2 deletions(-)
drivers/net/ethernet/intel/e1000e/ethtool.c +2 -1
index adce7e319b9e..aac0b7fb6243 100644
@@ -895,8 +895,8 @@ static int e1000_reg_test(struct e1000_adapter *adapter, u64 *data)
 	case e1000_pch_lpt:
 	case e1000_pch_spt:
 	case e1000_pch_cnp:
-		/* fall through */
 	case e1000_pch_tgp:
+	case e1000_pch_adp:
 		mask |= BIT(18);
 		break;
 	default:
@@ -1561,6 +1561,7 @@ static void e1000_loopback_cleanup(struct e1000_adapter *adapter)
 	case e1000_pch_spt:
 	case e1000_pch_cnp:
 	case e1000_pch_tgp:
+	case e1000_pch_adp:
 		fext_nvm11 = er32(FEXTNVM11);
 		fext_nvm11 &= ~E1000_FEXTNVM11_DISABLE_MULR_FIX;
 		ew32(FEXTNVM11, fext_nvm11);
drivers/net/ethernet/intel/e1000e/hw.h +5 -0
index f556163481cb..a1dbf8df1c70 100644
@@ -97,6 +97,10 @@ struct e1000_hw;
 #define E1000_DEV_ID_PCH_TGP_I219_LM14		0x15F9
 #define E1000_DEV_ID_PCH_TGP_I219_V14		0x15FA
 #define E1000_DEV_ID_PCH_TGP_I219_LM15		0x15F4
+#define E1000_DEV_ID_PCH_ADP_1219_LM16		0x1A1E
+#define E1000_DEV_ID_PCH_ADP_1219_V16		0x1A1F
+#define E1000_DEV_ID_PCH_ADP_1219_LM17		0x1A1C
+#define E1000_DEV_ID_PCH_ADP_1219_V17		0x1A1D
 
 #define E1000_REVISION_4	4
 
@@ -121,6 +125,7 @@ enum e1000_mac_type {
 	e1000_pch_spt,
 	e1000_pch_cnp,
 	e1000_pch_tgp,
+	e1000_pch_adp,
 };
 
 enum e1000_media_type {
drivers/net/ethernet/intel/e1000e/ich8lan.c +7 -0
index b4135c50e905..735bf25952fc 100644
@@ -317,6 +317,7 @@ static s32 e1000_init_phy_workarounds_pchlan(struct e1000_hw *hw)
 	case e1000_pch_spt:
 	case e1000_pch_cnp:
 	case e1000_pch_tgp:
+	case e1000_pch_adp:
 		if (e1000_phy_is_accessible_pchlan(hw))
 			break;
 
@@ -460,6 +461,7 @@ static s32 e1000_init_phy_params_pchlan(struct e1000_hw *hw)
 		case e1000_pch_spt:
 		case e1000_pch_cnp:
 		case e1000_pch_tgp:
+		case e1000_pch_adp:
 			/* In case the PHY needs to be in mdio slow mode,
 			 * set slow mode and try to get the PHY id again.
 			 */
@@ -703,6 +705,7 @@ static s32 e1000_init_mac_params_ich8lan(struct e1000_hw *hw)
 	case e1000_pch_spt:
 	case e1000_pch_cnp:
 	case e1000_pch_tgp:
+	case e1000_pch_adp:
 	case e1000_pchlan:
 		/* check management mode */
 		mac->ops.check_mng_mode = e1000_check_mng_mode_pchlan;
@@ -1642,6 +1645,7 @@ static s32 e1000_get_variants_ich8lan(struct e1000_adapter *adapter)
 	case e1000_pch_spt:
 	case e1000_pch_cnp:
 	case e1000_pch_tgp:
+	case e1000_pch_adp:
 		rc = e1000_init_phy_params_pchlan(hw);
 		break;
 	default:
@@ -2095,6 +2099,7 @@ static s32 e1000_sw_lcd_config_ich8lan(struct e1000_hw *hw)
 	case e1000_pch_spt:
 	case e1000_pch_cnp:
 	case e1000_pch_tgp:
+	case e1000_pch_adp:
 		sw_cfg_mask = E1000_FEXTNVM_SW_CONFIG_ICH8M;
 		break;
 	default:
@@ -3133,6 +3138,7 @@ static s32 e1000_valid_nvm_bank_detect_ich8lan(struct e1000_hw *hw, u32 *bank)
 	case e1000_pch_spt:
 	case e1000_pch_cnp:
 	case e1000_pch_tgp:
+	case e1000_pch_adp:
 		bank1_offset = nvm->flash_bank_size;
 		act_offset = E1000_ICH_NVM_SIG_WORD;
 
@@ -4077,6 +4083,7 @@ static s32 e1000_validate_nvm_checksum_ich8lan(struct e1000_hw *hw)
 	case e1000_pch_spt:
 	case e1000_pch_cnp:
 	case e1000_pch_tgp:
+	case e1000_pch_adp:
 		word = NVM_COMPAT;
 		valid_csum_mask = NVM_COMPAT_VALID_CSUM;
 		break;
drivers/net/ethernet/intel/e1000e/netdev.c +6 -1
index 60df6f2663c0..54b1768b1807 100644
@@ -3539,6 +3539,7 @@ s32 e1000e_get_base_timinca(struct e1000_adapter *adapter, u32 *timinca)
 		break;
 	case e1000_pch_cnp:
 	case e1000_pch_tgp:
+	case e1000_pch_adp:
 		if (er32(TSYNCRXCTL) & E1000_TSYNCRXCTL_SYSCFI) {
 			/* Stable 24MHz frequency */
 			incperiod = INCPERIOD_24MHZ;
@@ -4050,8 +4051,8 @@ void e1000e_reset(struct e1000_adapter *adapter)
 	case e1000_pch_lpt:
 	case e1000_pch_spt:
 	case e1000_pch_cnp:
-		/* fall-through */
 	case e1000_pch_tgp:
+	case e1000_pch_adp:
 		fc->refresh_time = 0xFFFF;
 		fc->pause_time = 0xFFFF;
 
@@ -7764,6 +7765,10 @@ static const struct pci_device_id e1000_pci_tbl[] = {
 	{ PCI_VDEVICE(INTEL, E1000_DEV_ID_PCH_TGP_I219_LM14), board_pch_cnp },
 	{ PCI_VDEVICE(INTEL, E1000_DEV_ID_PCH_TGP_I219_V14), board_pch_cnp },
 	{ PCI_VDEVICE(INTEL, E1000_DEV_ID_PCH_TGP_I219_LM15), board_pch_cnp },
+	{ PCI_VDEVICE(INTEL, E1000_DEV_ID_PCH_ADP_1219_LM16), board_pch_cnp },
+	{ PCI_VDEVICE(INTEL, E1000_DEV_ID_PCH_ADP_1219_V16), board_pch_cnp },
+	{ PCI_VDEVICE(INTEL, E1000_DEV_ID_PCH_ADP_1219_LM17), board_pch_cnp },
+	{ PCI_VDEVICE(INTEL, E1000_DEV_ID_PCH_ADP_1219_V17), board_pch_cnp },
 
 	{ 0, 0, 0, 0, 0, 0, 0 }	/* terminate list */
 };
drivers/net/ethernet/intel/e1000e/ptp.c +1 -0
index eaa5a0fb99f0..439fda2f5368 100644
@@ -297,6 +297,7 @@ void e1000e_ptp_init(struct e1000_adapter *adapter)
 	case e1000_pch_cnp:
 		/* fall-through */
 	case e1000_pch_tgp:
+	case e1000_pch_adp:
 		if ((hw->mac.type < e1000_pch_lpt) ||
 		    (er32(TSYNCRXCTL) & E1000_TSYNCRXCTL_SYSCFI)) {
 			adapter->ptp_clock_info.max_adj = 24000000 - 1;
Signature · 1 line
2.11.0
#1 lore raw

PATCH v2 1/1 e1000e: Add support for Alder Lake

Dear Sasha,

Am 19.01.20 um 08:46 schrieb Sasha Neftin:

Quoted 6 lines

Add devices ID's for the next LOM generations that will be available on the next Intel Client platform (Alder Lake) This patch provides the initial support for these devices

v1->v2:
Address comminuty comments

community

Quoted 14 lines
---
  drivers/net/ethernet/intel/e1000e/ethtool.c | 3 ++-
  drivers/net/ethernet/intel/e1000e/hw.h      | 5 +++++
  drivers/net/ethernet/intel/e1000e/ich8lan.c | 7 +++++++
  drivers/net/ethernet/intel/e1000e/netdev.c  | 7 ++++++-
  drivers/net/ethernet/intel/e1000e/ptp.c     | 1 +
  5 files changed, 21 insertions(+), 2 deletions(-)
drivers/net/ethernet/intel/e1000e/ethtool.c +0 -0
index adce7e319b9e..aac0b7fb6243 100644

drivers/net/ethernet/intel/e1000e/ethtool.c static int e1000_reg_test(struct e1000_adapter *adapter, u64 *data) · line 898

Quoted 4 lines
drivers/net/ethernet/intel/e1000e/ethtool.c +0 -1
@@ -895,8 +895,8 @@ static int e1000_reg_test(struct e1000_adapter *adapter, u64 *data)
  	case e1000_pch_lpt:
  	case e1000_pch_spt:
  	case e1000_pch_cnp:
-		/* fall through */

Please split this out, or mention this in a commit message. Also, there are more instances. If you want, I can sent a clean-up commit for the unnecessary fall-through comments.

[?]

Kind regards,

Paul

#2 lore raw

PATCH v2 1/1 e1000e: Add support for Alder Lake

Quoted 4 lines · Paul Menzel

Dear Sasha,

Am 19.01.20 um 08:46 schrieb Sasha Neftin:

Quoted 8 lines
Quoted 6 lines

Add devices ID's for the next LOM generations that will be available on the next Intel Client platform (Alder Lake) This patch provides the initial support for these devices

v1->v2:
Address comminuty comments

community

thanks, will fix the typo in v3

Quoted 26 lines
Quoted 17 lines

---

? drivers/net/ethernet/intel/e1000e/ethtool.c | 3 ++-
? drivers/net/ethernet/intel/e1000e/hw.h????? | 5 +++++
? drivers/net/ethernet/intel/e1000e/ich8lan.c | 7 +++++++
? drivers/net/ethernet/intel/e1000e/netdev.c? | 7 ++++++-
? drivers/net/ethernet/intel/e1000e/ptp.c???? | 1 +

? 5 files changed, 21 insertions(+), 2 deletions(-)

drivers/net/ethernet/intel/e1000e/ethtool.c +0 -0
index adce7e319b9e..aac0b7fb6243 100644
@@ -895,8 +895,8 @@ static int e1000_reg_test(struct e1000_adapter 
 *adapter, u64 *data)
Quoted 4 lines

????? case e1000_pch_lpt:
????? case e1000_pch_spt:
????? case e1000_pch_cnp:
-??????? /* fall through */

Please split this out, or mention this in a commit message. Also, there are more instances. If you want, I can sent a clean-up commit for the unnecessary fall-through comments.

Quoted 1 line

[?]

This is unrelated statement to this patch. I think we should process separate patch to clean up unneeded "fall through" statements. You can do it if you want, otherwise we will do it later.

Quoted 5 lines

Kind regards,

Paul