PATCH 1/1 enetc: permit configuration of rx-vlan-filter with ethtool

From: Vladimir Oltean <[email protected]>

Each ENETC station interface (SI) has a VLAN filter list and a port flag (PSIPVMR) by which it can be put in "VLAN promiscuous" mode, which enables the reception of VLAN-tagged traffic even if it is not in the VLAN filtering list.

Currently the handling of this setting works like this: the port starts off as VLAN promiscuous, then it switches to enabling VLAN filtering as soon as the first VLAN is installed in its filter via .ndo_vlan_rx_add_vid. In practice that does not work out very well, because more often than not, the first VLAN to be installed is out of the control of the user: the 8021q module, if loaded, adds its rule for 802.1p (VID 0) traffic upon bringing the interface up.

What the user is currently seeing in ethtool is this:
ethtool -k eno2
rx-vlan-filter: on [fixed]

which doesn't match the intention of the code, but the practical reality of having the 8021q module install its VID which has the side-effect of turning on VLAN filtering in this driver. All in all, a slightly confusing experience.

So instead of letting this driver switch the VLAN filtering state by itself, just wire it up with the rx-vlan-filter feature from ethtool, and let it be user-configurable just through that knob, except for one case, see below.

In promiscuous mode, it is more intuitive that all traffic is received, including VLAN tagged traffic. It appears that it is necessary to set the flag in PSIPVMR for that to be the case, so VLAN promiscuous mode is also temporarily enabled. On exit from promiscuous mode, the setting made by ethtool is restored.

---
 .../net/ethernet/freescale/enetc/enetc_pf.c   | 44 +++++++------------
 1 file changed, 16 insertions(+), 28 deletions(-)
drivers/net/ethernet/freescale/enetc/enetc_pf.c +16 -28
index ebcc0e74915a..671bf63f964d 100644
@@ -50,21 +50,6 @@ static void enetc_set_vlan_promisc(struct enetc_hw *hw, char si_map)
 	enetc_port_wr(hw, ENETC_PSIPVMR, ENETC_PSIPVMR_SET_VP(si_map) | val);
 }
 
-static bool enetc_si_vlan_promisc_is_on(struct enetc_pf *pf, int si_idx)
-{
-	return pf->vlan_promisc_simap & BIT(si_idx);
-}
-
-static bool enetc_vlan_filter_is_on(struct enetc_pf *pf)
-{
-	int i;
-
-	for_each_set_bit(i, pf->active_vlans, VLAN_N_VID)
-		return true;
-
-	return false;
-}
-
 static void enetc_enable_si_vlan_promisc(struct enetc_pf *pf, int si_idx)
 {
 	pf->vlan_promisc_simap |= BIT(si_idx);
@@ -204,6 +189,7 @@ static void enetc_pf_set_rx_mode(struct net_device *ndev)
 {
 	struct enetc_ndev_priv *priv = netdev_priv(ndev);
 	struct enetc_pf *pf = enetc_si_priv(priv->si);
+	char vlan_promisc_simap = pf->vlan_promisc_simap;
 	struct enetc_hw *hw = &priv->si->hw;
 	bool uprom = false, mprom = false;
 	struct enetc_mac_filter *filter;
@@ -216,16 +202,16 @@ static void enetc_pf_set_rx_mode(struct net_device *ndev)
 		psipmr = ENETC_PSIPMR_SET_UP(0) | ENETC_PSIPMR_SET_MP(0);
 		uprom = true;
 		mprom = true;
-		/* enable VLAN promisc mode for SI0 */
-		if (!enetc_si_vlan_promisc_is_on(pf, 0))
-			enetc_enable_si_vlan_promisc(pf, 0);
-
+		/* Enable VLAN promiscuous mode for SI0 (PF) */
+		vlan_promisc_simap |= BIT(0);
 	} else if (ndev->flags & IFF_ALLMULTI) {
 		/* enable multi cast promisc mode for SI0 (PF) */
 		psipmr = ENETC_PSIPMR_SET_MP(0);
 		mprom = true;
 	}
 
+	enetc_set_vlan_promisc(&pf->si->hw, vlan_promisc_simap);
+
 	/* first 2 filter entries belong to PF */
 	if (!uprom) {
 		/* Update unicast filters */
@@ -306,9 +292,6 @@ static int enetc_vlan_rx_add_vid(struct net_device *ndev, __be16 prot, u16 vid)
 	struct enetc_pf *pf = enetc_si_priv(priv->si);
 	int idx;
 
-	if (enetc_si_vlan_promisc_is_on(pf, 0))
-		enetc_disable_si_vlan_promisc(pf, 0);
-
 	__set_bit(vid, pf->active_vlans);
 
 	idx = enetc_vid_hash_idx(vid);
@@ -326,9 +309,6 @@ static int enetc_vlan_rx_del_vid(struct net_device *ndev, __be16 prot, u16 vid)
 	__clear_bit(vid, pf->active_vlans);
 	enetc_sync_vlan_ht_filter(pf, true);
 
-	if (!enetc_vlan_filter_is_on(pf))
-		enetc_enable_si_vlan_promisc(pf, 0);
-
 	return 0;
 }
 
@@ -681,6 +661,15 @@ static int enetc_pf_set_features(struct net_device *ndev,
 		enetc_enable_txvlan(&priv->si->hw, 0,
 				    !!(features & NETIF_F_HW_VLAN_CTAG_TX));
 
+	if (changed & NETIF_F_HW_VLAN_CTAG_FILTER) {
+		struct enetc_pf *pf = enetc_si_priv(priv->si);
+
+		if (!!(features & NETIF_F_HW_VLAN_CTAG_FILTER))
+			enetc_disable_si_vlan_promisc(pf, 0);
+		else
+			enetc_enable_si_vlan_promisc(pf, 0);
+	}
+
 	if (changed & NETIF_F_LOOPBACK)
 		enetc_set_loopback(ndev, !!(features & NETIF_F_LOOPBACK));
 
@@ -723,12 +712,11 @@ static void enetc_pf_netdev_setup(struct enetc_si *si, struct net_device *ndev,
 
 	ndev->hw_features = NETIF_F_SG | NETIF_F_RXCSUM | NETIF_F_HW_CSUM |
 			    NETIF_F_HW_VLAN_CTAG_TX | NETIF_F_HW_VLAN_CTAG_RX |
-			    NETIF_F_LOOPBACK;
+			    NETIF_F_HW_VLAN_CTAG_FILTER | NETIF_F_LOOPBACK;
 	ndev->features = NETIF_F_HIGHDMA | NETIF_F_SG |
 			 NETIF_F_RXCSUM | NETIF_F_HW_CSUM |
 			 NETIF_F_HW_VLAN_CTAG_TX |
-			 NETIF_F_HW_VLAN_CTAG_RX |
-			 NETIF_F_HW_VLAN_CTAG_FILTER;
+			 NETIF_F_HW_VLAN_CTAG_RX;
 
 	if (si->num_rss)
 		ndev->hw_features |= NETIF_F_RXHASH;
Signature · 1 line
2.17.1
Reviewed-by on v1 1/1
#1 lore raw
Quoted 29 lines · Vladimir Oltean

From: Vladimir Oltean <[email protected]>

Each ENETC station interface (SI) has a VLAN filter list and a port flag (PSIPVMR) by which it can be put in "VLAN promiscuous" mode, which enables the reception of VLAN-tagged traffic even if it is not in the VLAN filtering list.

Currently the handling of this setting works like this: the port starts off as VLAN promiscuous, then it switches to enabling VLAN filtering as soon as the first VLAN is installed in its filter via .ndo_vlan_rx_add_vid. In practice that does not work out very well, because more often than not, the first VLAN to be installed is out of the control of the user: the 8021q module, if loaded, adds its rule for 802.1p (VID 0) traffic upon bringing the interface up.

What the user is currently seeing in ethtool is this:
ethtool -k eno2
rx-vlan-filter: on [fixed]

which doesn't match the intention of the code, but the practical reality of having the 8021q module install its VID which has the side-effect of turning on VLAN filtering in this driver. All in all, a slightly confusing experience.

So instead of letting this driver switch the VLAN filtering state by itself, just wire it up with the rx-vlan-filter feature from ethtool, and let it be user-configurable just through that knob, except for one case, see below.

Quoted 7 lines

In promiscuous mode, it is more intuitive that all traffic is received, including VLAN tagged traffic. It appears that it is necessary to set the flag in PSIPVMR for that to be the case, so VLAN promiscuous mode is also temporarily enabled. On exit from promiscuous mode, the setting made by ethtool is restored.

This patch is a good candidate for the net tree.

Thanks,
Claudiu

maintainer Applied
#2 lore raw
In reply to Vladimir Oltean

From: Vladimir Oltean <[email protected]>
Date: Fri, 17 Apr 2020 22:07:55 +0300

Quoted 29 lines

From: Vladimir Oltean <[email protected]>

Each ENETC station interface (SI) has a VLAN filter list and a port flag (PSIPVMR) by which it can be put in "VLAN promiscuous" mode, which enables the reception of VLAN-tagged traffic even if it is not in the VLAN filtering list.

Currently the handling of this setting works like this: the port starts off as VLAN promiscuous, then it switches to enabling VLAN filtering as soon as the first VLAN is installed in its filter via .ndo_vlan_rx_add_vid. In practice that does not work out very well, because more often than not, the first VLAN to be installed is out of the control of the user: the 8021q module, if loaded, adds its rule for 802.1p (VID 0) traffic upon bringing the interface up.

What the user is currently seeing in ethtool is this:
ethtool -k eno2
rx-vlan-filter: on [fixed]

which doesn't match the intention of the code, but the practical reality of having the 8021q module install its VID which has the side-effect of turning on VLAN filtering in this driver. All in all, a slightly confusing experience.

So instead of letting this driver switch the VLAN filtering state by itself, just wire it up with the rx-vlan-filter feature from ethtool, and let it be user-configurable just through that knob, except for one case, see below.

Quoted 7 lines

In promiscuous mode, it is more intuitive that all traffic is received, including VLAN tagged traffic. It appears that it is necessary to set the flag in PSIPVMR for that to be the case, so VLAN promiscuous mode is also temporarily enabled. On exit from promiscuous mode, the setting made by ethtool is restored.

Applied.