PATCH 1/3 dt-bindings: mfd: Document the RTC present on MAX77620
From: Thierry Reding <[email protected]>
The RTC present on MAX77620 can be used to generate an alarm at a given time, which in turn can be used as a wakeup source for the system if it is properly wired up.
Document how to enable the RTC to act as a wakeup source.
--- .../devicetree/bindings/mfd/max77620.txt | 15 +++++++++++++++ 1 file changed, 15 insertions(+)
Documentation/devicetree/bindings/mfd/max77620.txt +15 -0
@@ -125,6 +125,17 @@ MAX77663 supports 20, 40, 80, 160, 320, 640, 1280 and 2540 microseconds. control) then, GPIO1/nRST_IO goes LOW. this property is valid for max20024 only. +Realtime Clock +-------------- +The MAX77620 family of power management ICs contain a realtime clock block +that can be used to keep track of time even when the system is powered off. + +The realtime clock can also be programmed to trigger alerts, which can be +used to wake the system up from sleep. In order to configure the RTC to act +as a wakeup source, add an "rtc" child node and add the "wakeup-source" +property. + + For DT binding details of different sub modules like GPIO, pincontrol, regulator, power, please refer respective device-tree binding document under their respective sub-system directories.
@@ -159,4 +170,8 @@ max77620@3c { maxim,fps-event-source = <MAX77620_FPS_EVENT_SRC_SW>; }; }; + + rtc { + wakeup-source; + }; };
Signature · 1 line
2.24.1
PATCH 2/3 rtc: max77686: Make wakeup support configurable
From: Thierry Reding <[email protected]>
Use the standard "wakeup-source" device tree property to determine if the RTC can act as a wakeup source for the system. Note that the driver by default always assumes that the RTC can act as a wakeup source, but whether it can really do so or not always depends on how it is hooked up.
In order to preserve backwards compatibility with older device trees, only parse the "wakeup-source" property when a device tree node was associated with the RTC device. This doesn't typically happen because the top-level MFD driver doesn't list any compatible strings that can be used to map child nodes to child devices. As a fallback, check if a child node named "rtc" exists and use that instead.
---
Note that we could obviously add support to the MFD driver to match subdevices to their device tree nodes by compatible string, but there are side-effects, such as the driver core complaining about the lack of a DMA mask for these devices. That in turn could also be fixed but it ends up all being rather hacky, so just looking up a child node by name seems like a good compromise, especially since there are already such subnodes for some of the other subdevices of this PMIC.
--- drivers/rtc/rtc-max77686.c | 18 +++++++++++++++++- 1 file changed, 17 insertions(+), 1 deletion(-)
drivers/rtc/rtc-max77686.c +17 -1
@@ -722,6 +722,8 @@ static int max77686_rtc_probe(struct platform_device *pdev) {struct max77686_rtc_info *info;const struct platform_device_id *id =platform_get_device_id (pdev); +struct device_node *np =of_node_get (pdev->dev.of_node); +bool wakeup = true;int ret; info = devm_kzalloc(&pdev->dev, sizeof(struct max77686_rtc_info),
@@ -746,7 +748,21 @@ static int max77686_rtc_probe(struct platform_device *pdev) goto err_rtc; } -device_init_wakeup (&pdev->dev,1 ); +/* +* Only check for the wakeup-source property if there's an actual +* device tree node for the RTC. If no device tree node had been +* attached during device instantiation, try looking up the "rtc" +* child node of the parent's device tree node. +*/ +if (!np && pdev->dev.parent->of_node) + np =of_get_child_by_name (pdev->dev.parent->of_node,"rtc" ); + +if (np) { + wakeup =of_property_read_bool (np,"wakeup-source" ); +of_node_put (np); + } + +device_init_wakeup (&pdev->dev, wakeup); info->rtc_dev =devm_rtc_device_register (&pdev->dev, id->name, &max77686_rtc_ops,THIS_MODULE );
Signature · 1 line
2.24.1
Re: [PATCH 2/3] rtc: max77686: Make wakeup support configurable
Quoted 55 lines · Thierry Reding
From: Thierry Reding <[email protected]>
Use the standard "wakeup-source" device tree property to determine if the RTC can act as a wakeup source for the system. Note that the driver by default always assumes that the RTC can act as a wakeup source, but whether it can really do so or not always depends on how it is hooked up.
In order to preserve backwards compatibility with older device trees, only parse the "wakeup-source" property when a device tree node was associated with the RTC device. This doesn't typically happen because the top-level MFD driver doesn't list any compatible strings that can be used to map child nodes to child devices. As a fallback, check if a child node named "rtc" exists and use that instead.
Signed-off-by Thierry Reding <[email protected]>---
Note that we could obviously add support to the MFD driver to match subdevices to their device tree nodes by compatible string, but there are side-effects, such as the driver core complaining about the lack of a DMA mask for these devices. That in turn could also be fixed but it ends up all being rather hacky, so just looking up a child node by name seems like a good compromise, especially since there are already such subnodes for some of the other subdevices of this PMIC.--- drivers/rtc/rtc-max77686.c | 18 +++++++++++++++++- 1 file changed, 17 insertions(+), 1 deletion(-)drivers/rtc/rtc-max77686.c +10
-1@@ -722,6 +722,8 @@ static int max77686_rtc_probe(struct platform_device *pdev) {struct max77686_rtc_info *info;const struct platform_device_id *id =platform_get_device_id (pdev); +struct device_node *np =of_node_get (pdev->dev.of_node); +bool wakeup = true;int ret; info = devm_kzalloc(&pdev->dev, sizeof(struct max77686_rtc_info),@@ -746,7 +748,21 @@ static int max77686_rtc_probe(struct platform_device *pdev) goto err_rtc; } -device_init_wakeup (&pdev->dev,1 ); +/* +* Only check for the wakeup-source property if there's an actual +* device tree node for the RTC. If no device tree node had been +* attached during device instantiation, try looking up the "rtc" +* child node of the parent's device tree node. +*/ +if (!np && pdev->dev.parent->of_node) + np =of_get_child_by_name (pdev->dev.parent->of_node,"rtc" );
drivers/rtc/rtc-max77686.c static int max77686_rtc_probe(struct platform_device *pdev) · line 768
Quoted 10 lines
drivers/rtc/rtc-max77686.c +7
-0+ +if (np) { + wakeup =of_property_read_bool (np,"wakeup-source" ); +of_node_put (np); + } + +device_init_wakeup (&pdev->dev, wakeup); info->rtc_dev =devm_rtc_device_register (&pdev->dev, id->name, &max77686_rtc_ops,THIS_MODULE );
Cheers
Jon
Signature · 1 line
nvpublic
PATCH 3/3 rtc: max77686: Use single-byte writes on MAX77620
In reply to Thierry RedingFrom: Thierry Reding <[email protected]>
The MAX77620 doesn't support bulk writes, so make sure the regmap code breaks bulk writes into multiple single-byte writes.
--- drivers/rtc/rtc-max77686.c | 22 ++++++++++++++++------ 1 file changed, 16 insertions(+), 6 deletions(-)
drivers/rtc/rtc-max77686.c +16 -6
@@ -78,6 +78,8 @@ struct max77686_rtc_driver_data {int alarm_pending_status_reg;/* RTC IRQ CHIP for regmap */ const struct regmap_irq_chip *rtc_irq_chip; +/* regmap configuration for the chip */ +const struct regmap_config *regmap_config; };struct max77686_rtc_info {
@@ -182,6 +184,11 @@ static const struct regmap_irq_chip max77686_rtc_irq_chip = { .num_irqs = ARRAY_SIZE(max77686_rtc_irqs), }; +static const struct regmap_config max77686_rtc_regmap_config = { + .reg_bits =8 , + .val_bits =8 , +}; +static const struct max77686_rtc_driver_data max77686_drv_data = { .delay =16000 , .mask =0x7f ,
@@ -191,6 +198,13 @@ static const struct max77686_rtc_driver_data max77686_drv_data = { .alarm_pending_status_reg = MAX77686_REG_STATUS2, .rtc_i2c_addr = MAX77686_I2C_ADDR_RTC, .rtc_irq_chip = &max77686_rtc_irq_chip, + .regmap_config = &max77686_rtc_regmap_config, +}; + +static const struct regmap_config max77620_rtc_regmap_config = { + .reg_bits =8 , + .val_bits =8 , + .use_single_write = true, };static const struct max77686_rtc_driver_data max77620_drv_data = {
@@ -202,6 +216,7 @@ static const struct max77686_rtc_driver_data max77620_drv_data = { .alarm_pending_status_reg = MAX77686_INVALID_REG, .rtc_i2c_addr = MAX77620_I2C_ADDR_RTC, .rtc_irq_chip = &max77686_rtc_irq_chip, + .regmap_config = &max77620_rtc_regmap_config, };static const unsigned int max77802_map[REG_RTC_END ] = {
@@ -658,11 +673,6 @@ static int max77686_rtc_init_reg(struct max77686_rtc_info *info)return ret; } -static const struct regmap_config max77686_rtc_regmap_config = { - .reg_bits =8 , - .val_bits =8 , -}; -static int max77686_init_rtc_regmap (struct max77686_rtc_info *info) {struct device *parent = info->dev->parent;
@@ -698,7 +708,7 @@ static int max77686_init_rtc_regmap(struct max77686_rtc_info *info) } info->rtc_regmap =devm_regmap_init_i2c (info->rtc, - &max77686_rtc_regmap_config); + info->drv_data->regmap_config);if (IS_ERR (info->rtc_regmap)) { ret =PTR_ERR (info->rtc_regmap);dev_err (info->dev,"Failed to allocate RTC regmap: %d\n" , ret);
Signature · 1 line
2.24.1
Re: [PATCH 3/3] rtc: max77686: Use single-byte writes on MAX77620
Quoted 71 lines · Thierry Reding
From: Thierry Reding <[email protected]>
The MAX77620 doesn't support bulk writes, so make sure the regmap code breaks bulk writes into multiple single-byte writes.
Signed-off-by Thierry Reding <[email protected]>--- drivers/rtc/rtc-max77686.c | 22 ++++++++++++++++------ 1 file changed, 16 insertions(+), 6 deletions(-)drivers/rtc/rtc-max77686.c +15
-5@@ -78,6 +78,8 @@ struct max77686_rtc_driver_data {int alarm_pending_status_reg;/* RTC IRQ CHIP for regmap */ const struct regmap_irq_chip *rtc_irq_chip; +/* regmap configuration for the chip */ +const struct regmap_config *regmap_config; };struct max77686_rtc_info {@@ -182,6 +184,11 @@ static const struct regmap_irq_chip max77686_rtc_irq_chip = { .num_irqs = ARRAY_SIZE(max77686_rtc_irqs), }; +static const struct regmap_config max77686_rtc_regmap_config = { + .reg_bits =8 , + .val_bits =8 , +}; +static const struct max77686_rtc_driver_data max77686_drv_data = { .delay =16000 , .mask =0x7f ,@@ -191,6 +198,13 @@ static const struct max77686_rtc_driver_data max77686_drv_data = { .alarm_pending_status_reg = MAX77686_REG_STATUS2, .rtc_i2c_addr = MAX77686_I2C_ADDR_RTC, .rtc_irq_chip = &max77686_rtc_irq_chip, + .regmap_config = &max77686_rtc_regmap_config, +}; + +static const struct regmap_config max77620_rtc_regmap_config = { + .reg_bits =8 , + .val_bits =8 , + .use_single_write = true, };static const struct max77686_rtc_driver_data max77620_drv_data = {@@ -202,6 +216,7 @@ static const struct max77686_rtc_driver_data max77620_drv_data = { .alarm_pending_status_reg = MAX77686_INVALID_REG, .rtc_i2c_addr = MAX77620_I2C_ADDR_RTC, .rtc_irq_chip = &max77686_rtc_irq_chip, + .regmap_config = &max77620_rtc_regmap_config, };static const unsigned int max77802_map[REG_RTC_END ] = {@@ -658,11 +673,6 @@ static int max77686_rtc_init_reg(struct max77686_rtc_info *info)return ret; } -static const struct regmap_config max77686_rtc_regmap_config = { - .reg_bits =8 , - .val_bits =8 , -}; -static int max77686_init_rtc_regmap (struct max77686_rtc_info *info) {struct device *parent = info->dev->parent;
drivers/rtc/rtc-max77686.c static int max77686_init_rtc_regmap(struct max77686_rtc_info *info) · line 714
Quoted 8 lines
drivers/rtc/rtc-max77686.c +1
-1@@ -698,7 +708,7 @@ static int max77686_init_rtc_regmap(struct max77686_rtc_info *info) } info->rtc_regmap =devm_regmap_init_i2c (info->rtc, - &max77686_rtc_regmap_config); + info->drv_data->regmap_config);if (IS_ERR (info->rtc_regmap)) { ret =PTR_ERR (info->rtc_regmap);dev_err (info->dev,"Failed to allocate RTC regmap: %d\n" , ret);
Cheers
Jon
Signature · 1 line
nvpublic
Re: [PATCH 3/3] rtc: max77686: Use single-byte writes on MAX77620
In reply to Thierry RedingQuoted 10 lines · Thierry Reding
From: Thierry Reding <[email protected]>
The MAX77620 doesn't support bulk writes, so make sure the regmap code breaks bulk writes into multiple single-byte writes.
Signed-off-by Thierry Reding <[email protected]>--- drivers/rtc/rtc-max77686.c | 22 ++++++++++++++++------ 1 file changed, 16 insertions(+), 6 deletions(-)
Applied, thanks.
Signature · 3 lines
Alexandre Belloni, Bootlin Embedded Linux and Kernel engineering https://bootlin.com
Rob Herring
maintainerQuoted 36 lines · Thierry Reding
From: Thierry Reding <[email protected]>
The RTC present on MAX77620 can be used to generate an alarm at a given time, which in turn can be used as a wakeup source for the system if it is properly wired up.
Document how to enable the RTC to act as a wakeup source.
Signed-off-by Thierry Reding <[email protected]>--- .../devicetree/bindings/mfd/max77620.txt | 15 +++++++++++++++ 1 file changed, 15 insertions(+)Documentation/devicetree/bindings/mfd/max77620.txt +11
-0@@ -125,6 +125,17 @@ MAX77663 supports 20, 40, 80, 160, 320, 640, 1280 and 2540 microseconds. control) then, GPIO1/nRST_IO goes LOW. this property is valid for max20024 only. +Realtime Clock +-------------- +The MAX77620 family of power management ICs contain a realtime clock block +that can be used to keep track of time even when the system is powered off. + +The realtime clock can also be programmed to trigger alerts, which can be +used to wake the system up from sleep. In order to configure the RTC to act +as a wakeup source, add an "rtc" child node and add the "wakeup-source" +property. + + For DT binding details of different sub modules like GPIO, pincontrol, regulator, power, please refer respective device-tree binding document under their respective sub-system directories.
Documentation/devicetree/bindings/mfd/max77620.txt max77620@3c { · line 175
Quoted 6 lines
Documentation/devicetree/bindings/mfd/max77620.txt +3
-0@@ -159,4 +170,8 @@ max77620@3c { maxim,fps-event-source = <MAX77620_FPS_EVENT_SRC_SW>; }; }; + + rtc { + wakeup-source;
Is the RTC really the only thing that could wake the system in this PMIC?
I don't think it's really valid to have 'wakeup-source' without 'interrupts' unless the wakeup mechanism is somehow not an interrupt. So I think this belongs in the parent node.
Rob
Alexandre Belloni
maintainerQuoted 47 lines · Rob Herring
Quoted 36 lines · Thierry Reding
From: Thierry Reding <[email protected]>
The RTC present on MAX77620 can be used to generate an alarm at a given time, which in turn can be used as a wakeup source for the system if it is properly wired up.
Document how to enable the RTC to act as a wakeup source.
Signed-off-by Thierry Reding <[email protected]>--- .../devicetree/bindings/mfd/max77620.txt | 15 +++++++++++++++ 1 file changed, 15 insertions(+)Documentation/devicetree/bindings/mfd/max77620.txt +11
-0@@ -125,6 +125,17 @@ MAX77663 supports 20, 40, 80, 160, 320, 640, 1280 and 2540 microseconds. control) then, GPIO1/nRST_IO goes LOW. this property is valid for max20024 only. +Realtime Clock +-------------- +The MAX77620 family of power management ICs contain a realtime clock block +that can be used to keep track of time even when the system is powered off. + +The realtime clock can also be programmed to trigger alerts, which can be +used to wake the system up from sleep. In order to configure the RTC to act +as a wakeup source, add an "rtc" child node and add the "wakeup-source" +property. + + For DT binding details of different sub modules like GPIO, pincontrol, regulator, power, please refer respective device-tree binding document under their respective sub-system directories.Documentation/devicetree/bindings/mfd/max77620.txt max77620@3c { · line 175
Quoted 6 lines
Documentation/devicetree/bindings/mfd/max77620.txt +3
-0@@ -159,4 +170,8 @@ max77620@3c { maxim,fps-event-source = <MAX77620_FPS_EVENT_SRC_SW>; }; }; + + rtc { + wakeup-source;Is the RTC really the only thing that could wake the system in this PMIC?
Quoted 4 lines
I don't think it's really valid to have 'wakeup-source' without 'interrupts' unless the wakeup mechanism is somehow not an interrupt. So I think this belongs in the parent node.
I don't think this is true because in the case of a discrete RTC, its interrupt pin can be connected directly to a PMIC to power up a board instead of being connected to the SoC. In that case we don't have an interrupt property but the RTC is still a wakeup source. This is the usual use case for wakeup-source in the RTC subsystem. Else, if there is an interrupt, then we assume the RTC is a wakeup source and there is no need to have the wakeup-source property.
Signature · 3 lines
Alexandre Belloni, Bootlin Embedded Linux and Kernel engineering https://bootlin.com
Rob Herring
maintainerQuoted 54 lines · Alexandre Belloni
Quoted 47 lines · Rob Herring
Quoted 36 lines · Thierry Reding
From: Thierry Reding <[email protected]>
The RTC present on MAX77620 can be used to generate an alarm at a given time, which in turn can be used as a wakeup source for the system if it is properly wired up.
Document how to enable the RTC to act as a wakeup source.
Signed-off-by Thierry Reding <[email protected]>--- .../devicetree/bindings/mfd/max77620.txt | 15 +++++++++++++++ 1 file changed, 15 insertions(+)Documentation/devicetree/bindings/mfd/max77620.txt +11
-0@@ -125,6 +125,17 @@ MAX77663 supports 20, 40, 80, 160, 320, 640, 1280 and 2540 microseconds. control) then, GPIO1/nRST_IO goes LOW. this property is valid for max20024 only. +Realtime Clock +-------------- +The MAX77620 family of power management ICs contain a realtime clock block +that can be used to keep track of time even when the system is powered off. + +The realtime clock can also be programmed to trigger alerts, which can be +used to wake the system up from sleep. In order to configure the RTC to act +as a wakeup source, add an "rtc" child node and add the "wakeup-source" +property. + + For DT binding details of different sub modules like GPIO, pincontrol, regulator, power, please refer respective device-tree binding document under their respective sub-system directories.Documentation/devicetree/bindings/mfd/max77620.txt max77620@3c { · line 175
Quoted 6 lines
Documentation/devicetree/bindings/mfd/max77620.txt +3
-0@@ -159,4 +170,8 @@ max77620@3c { maxim,fps-event-source = <MAX77620_FPS_EVENT_SRC_SW>; }; }; + + rtc { + wakeup-source;Is the RTC really the only thing that could wake the system in this PMIC?
Quoted 4 lines
I don't think it's really valid to have 'wakeup-source' without 'interrupts' unless the wakeup mechanism is somehow not an interrupt. So I think this belongs in the parent node.
Quoted 7 lines
I don't think this is true because in the case of a discrete RTC, its interrupt pin can be connected directly to a PMIC to power up a board instead of being connected to the SoC. In that case we don't have an interrupt property but the RTC is still a wakeup source. This is the usual use case for wakeup-source in the RTC subsystem. Else, if there is an interrupt, then we assume the RTC is a wakeup source and there is no need to have the wakeup-source property.
Yes, that would be an example of "unless the wakeup mechanism is somehow not an interrupt". I guess I should add not an interrupt from the perspective of the OS.
So if the wakeup is self contained within the PMIC, why do we need a DT property? The capability is always there and enabling/disabling wakeup from it is userspace policy.
Rob
Alexandre Belloni
maintainerQuoted 8 lines · Rob Herring
Quoted 7 lines
I don't think this is true because in the case of a discrete RTC, its interrupt pin can be connected directly to a PMIC to power up a board instead of being connected to the SoC. In that case we don't have an interrupt property but the RTC is still a wakeup source. This is the usual use case for wakeup-source in the RTC subsystem. Else, if there is an interrupt, then we assume the RTC is a wakeup source and there is no need to have the wakeup-source property.
Quoted 8 lines
Yes, that would be an example of "unless the wakeup mechanism is somehow not an interrupt". I guess I should add not an interrupt from the perspective of the OS.
So if the wakeup is self contained within the PMIC, why do we need a DT property? The capability is always there and enabling/disabling wakeup from it is userspace policy.
Yes, for this particular case, I'm not sure wakeup-source is actually necessary. If the interrupt line is used to wakeup the SoC, then the presence of the interrupts property is enough to enable wakeup.
Signature · 3 lines
Alexandre Belloni, Bootlin Embedded Linux and Kernel engineering https://bootlin.com
Quoted 13 lines · Alexandre Belloni
Quoted 12 lines · Rob Herring
Quoted 7 lines
I don't think this is true because in the case of a discrete RTC, its interrupt pin can be connected directly to a PMIC to power up a board instead of being connected to the SoC. In that case we don't have an interrupt property but the RTC is still a wakeup source. This is the usual use case for wakeup-source in the RTC subsystem. Else, if there is an interrupt, then we assume the RTC is a wakeup source and there is no need to have the wakeup-source property.
Yes, that would be an example of "unless the wakeup mechanism is somehow not an interrupt". I guess I should add not an interrupt from the perspective of the OS.
Quoted 8 lines
Quoted 4 lines
So if the wakeup is self contained within the PMIC, why do we need a DT property? The capability is always there and enabling/disabling wakeup from it is userspace policy.
Yes, for this particular case, I'm not sure wakeup-source is actually necessary. If the interrupt line is used to wakeup the SoC, then the presence of the interrupts property is enough to enable wakeup.
So yes, the wakeup-source property isn't necessary. The goal of patches 1 and 2 was to allow the RTC to be actually disabled as a wakeup-source in case it didn't work as intended. But since the RTC is enabled as a wakeup source on these PMICs by default, the idea was to add a new sub- node for the RTC and required the wakeup-source in that subnode if that subnode was present.
That said, patch 3 actually does make the RTC work as a wakeup source on the particular board that I tested this, so patches 1 and 2 are no longer really required from my point of view.
Do you want me to send patch 3/3 again separately or can you pick it up from this series?
Thanks,
Thierry
Alexandre Belloni
maintainerHi,
Quoted 30 lines · Thierry Reding
Quoted 13 lines · Alexandre Belloni
Quoted 12 lines · Rob Herring
Quoted 7 lines
I don't think this is true because in the case of a discrete RTC, its interrupt pin can be connected directly to a PMIC to power up a board instead of being connected to the SoC. In that case we don't have an interrupt property but the RTC is still a wakeup source. This is the usual use case for wakeup-source in the RTC subsystem. Else, if there is an interrupt, then we assume the RTC is a wakeup source and there is no need to have the wakeup-source property.
Yes, that would be an example of "unless the wakeup mechanism is somehow not an interrupt". I guess I should add not an interrupt from the perspective of the OS.
Quoted 8 lines
Quoted 4 lines
So if the wakeup is self contained within the PMIC, why do we need a DT property? The capability is always there and enabling/disabling wakeup from it is userspace policy.
Yes, for this particular case, I'm not sure wakeup-source is actually necessary. If the interrupt line is used to wakeup the SoC, then the presence of the interrupts property is enough to enable wakeup.
So yes, the wakeup-source property isn't necessary. The goal of patches 1 and 2 was to allow the RTC to be actually disabled as a wakeup-source in case it didn't work as intended. But since the RTC is enabled as a wakeup source on these PMICs by default, the idea was to add a new sub- node for the RTC and required the wakeup-source in that subnode if that subnode was present.
Quoted 7 lines
That said, patch 3 actually does make the RTC work as a wakeup source on the particular board that I tested this, so patches 1 and 2 are no longer really required from my point of view.
Do you want me to send patch 3/3 again separately or can you pick it up from this series?
I applied it.