It looks like the sja1105 external timestamping input is not as generic as we thought. When fed a signal with 50% duty cycle, it will timestamp both the rising and the falling edge. When fed a short pulse signal, only the timestamp of the falling edge will be seen in the PTPSYNCTS register, because that of the rising edge had been overwritten. So the moral is: don't feed it short pulse inputs.
Luckily this is not a complete deal breaker, as we can still work with 1 Hz square waves. But the problem is that the extts polling period was not dimensioned enough for this input signal. If we leave the period at half a second, we risk losing timestamps due to jitter in the measuring process. So we need to increase it to 4 times per second.
Also, the very least we can do to inform the user is to deny any other flags combination than with PTP_RISING_EDGE and PTP_FALLING_EDGE both set.
--- drivers/net/dsa/sja1105/sja1105_ptp.c | 26 ++++++++++++++++++-------- 1 file changed, 18 insertions(+), 8 deletions(-)
drivers/net/dsa/sja1105/sja1105_ptp.c +18 -8
@@ -16,14 +16,15 @@/* PTPSYNCTS has no interrupt or update mechanism, because the intended * hardware use case is for the timestamp to be collected synchronously, -* immediately after the CAS_MASTER SJA1105 switch has triggered a CASSYNC -* pulse on the PTP_CLK pin. When used as a generic extts source, it needs -* polling and a comparison with the old value. The polling interval is just -* the Nyquist rate of a canonical PPS input (e.g. from a GPS module). -* Anything of higher frequency than 1 Hz will be lost, since there is no -* timestamp FIFO. +* immediately after the CAS_MASTER SJA1105 switch has performed a CASSYNC +* one-shot toggle (no return to level) on the PTP_CLK pin. When used as a +* generic extts source, the PTPSYNCTS register needs polling and a comparison +* with the old value. The polling interval is configured as the Nyquist rate +* of a signal with 50% duty cycle and 1Hz frequency, which is sadly all that +* this hardware can do (but may be enough for some setups). Anything of higher +* frequency than 1 Hz will be lost, since there is no timestamp FIFO. */ -#define SJA1105_EXTTS_INTERVAL (HZ / 2) +#define SJA1105_EXTTS_INTERVAL (HZ / 4)/* This range is actually +/- SJA1105_MAX_ADJ_PPB * divided by 1000 (ppb -> ppm) and with a 16-bit
@@ -754,7 +755,16 @@ static int sja1105_extts_enable(struct sja1105_private *priv,return -EOPNOTSUPP ;/* Reject requests with unsupported flags */ -if (extts->flags) +if (extts->flags & ~(PTP_ENABLE_FEATURE | +PTP_RISING_EDGE | +PTP_FALLING_EDGE | +PTP_STRICT_FLAGS )) +return -EOPNOTSUPP ; + +/* We can only enable time stamping on both edges, sadly. */ +if ((extts->flags &PTP_STRICT_FLAGS ) && + (extts->flags &PTP_ENABLE_FEATURE ) && + (extts->flags &PTP_EXTTS_EDGES ) !=PTP_EXTTS_EDGES )return -EOPNOTSUPP ; rc =sja1105_change_ptp_clk_pin_func (priv,PTP_PF_EXTTS );
Signature · 1 line
2.17.1
Quoted 15 lines · Vladimir Oltean
From: Vladimir Oltean <[email protected]>
It looks like the sja1105 external timestamping input is not as generic as we thought. When fed a signal with 50% duty cycle, it will timestamp both the rising and the falling edge. When fed a short pulse signal, only the timestamp of the falling edge will be seen in the PTPSYNCTS register, because that of the rising edge had been overwritten. So the moral is: don't feed it short pulse inputs.
Luckily this is not a complete deal breaker, as we can still work with 1 Hz square waves. But the problem is that the extts polling period was not dimensioned enough for this input signal. If we leave the period at half a second, we risk losing timestamps due to jitter in the measuring process. So we need to increase it to 4 times per second.
Quoted 6 lines
Also, the very least we can do to inform the user is to deny any other flags combination than with
PTP_RISING_EDGEandPTP_FALLING_EDGEboth set.Fixes 747e5eb31d59 ("net: dsa: sja1105: configure the PTP_CLK pin as EXT_TS or PER_OUT")Signed-off-by Vladimir Oltean <[email protected]>
From: Vladimir Oltean <[email protected]>
Date: Wed, 6 May 2020 20:48:13 +0300
Quoted 15 lines
From: Vladimir Oltean <[email protected]>
It looks like the sja1105 external timestamping input is not as generic as we thought. When fed a signal with 50% duty cycle, it will timestamp both the rising and the falling edge. When fed a short pulse signal, only the timestamp of the falling edge will be seen in the PTPSYNCTS register, because that of the rising edge had been overwritten. So the moral is: don't feed it short pulse inputs.
Luckily this is not a complete deal breaker, as we can still work with 1 Hz square waves. But the problem is that the extts polling period was not dimensioned enough for this input signal. If we leave the period at half a second, we risk losing timestamps due to jitter in the measuring process. So we need to increase it to 4 times per second.
Quoted 6 lines
Also, the very least we can do to inform the user is to deny any other flags combination than with
PTP_RISING_EDGEandPTP_FALLING_EDGEboth set.Fixes 747e5eb31d59 ("net: dsa: sja1105: configure the PTP_CLK pin as EXT_TS or PER_OUT")Signed-off-by Vladimir Oltean <[email protected]>