Hi Andrew,

First of all, great work! As your cable diagnostic patches are in net-next now and can be used as base for the follow-up discussion.

Do you already have ethtool patches somewhere? :=) Can you please give a link for testing?

I continue to work on TJA11xx PHY and need to export some additional cable diagnostic/link stability information: Signal Quality Index (SQI). The PHY data sheet describes it as following [1]:
================================================================================
6.10.3 Link stability

The signal-to-noise ratio is the parameter used to estimate link stability. The PMA Receive function monitors the signal-to-noise ratio continuously. Once the signal-to-noise ratio falls below a configurable threshold (SQI_FAILLIMIT), the link status is set to FAIL and communication is interrupted. The TJA1100 allows for adjusting the sensitivity of the PMA Receive function by configuring this threshold. The microcontroller can always check the current value of the signal-to-noise ratio via the SMI, allowing it to track a possible degradation in link stability.
================================================================================

Since this functionality is present at least on TJA11xx PHYs and mandatory according to Open Alliance[2], I hope this functionality is present on other 100/1000Base-T1 PHYs. So may be some common abstraction is possible. What would be the best place to provide it for the user space? According to the [2] SQI, is the part of Dynamic Channel Quality (DCQ) together with Mean Square Error (MSE) and Peak MSE value (pMSE).

[1] https://www.nxp.com/docs/en/data-sheet/TJA1100.pdf
[2] http://www.opensig.org/download/document/218/Advanced_PHY_features_for_automotive_Ethernet_V1.0.pdf

    http://www.opensig.org/download/document/225/Open_Alliance_100BASE-T1_PMA_Test_Suite_v1.0-dec.pdf
Signature · 4 lines
Pengutronix e.K.                           |                             |
Steuerwalder Str. 21                       | http://www.pengutronix.de/  |
31137 Hildesheim, Germany                  | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |
#1 lore raw
Quoted 7 lines · Oleksij Rempel

Hi Andrew,

First of all, great work! As your cable diagnostic patches are in net-next now and can be used as base for the follow-up discussion.

Do you already have ethtool patches somewhere? :=) Can you please give a link for testing?

Hi Oleksij

It was mentioned in the cover note

https://github.com/lunn/ethtool/tree/feature/cable-test-v4

Quoted 3 lines

I continue to work on TJA11xx PHY and need to export some additional cable diagnostic/link stability information: Signal Quality Index (SQI).

Is this something you want to continually make available, or just as part of cable diagnostics. Additional nested attributes can be added to the cable test results structure, and the user space code just dumps whatever it finds. So it should be easy to have something like:

Pair A: OK
Pair A: Signal Quality Index class D

Are the classes part of the Open Alliance specification? Ideally we want to report something standardized, not something proprietary to NXP.

Andrew

#2 lore raw
Quoted 19 lines · Andrew Lunn
Quoted 7 lines · Oleksij Rempel

Hi Andrew,

First of all, great work! As your cable diagnostic patches are in net-next now and can be used as base for the follow-up discussion.

Do you already have ethtool patches somewhere? :=) Can you please give a link for testing?

Hi Oleksij

It was mentioned in the cover note

https://github.com/lunn/ethtool/tree/feature/cable-test-v4

Quoted 3 lines

I continue to work on TJA11xx PHY and need to export some additional cable diagnostic/link stability information: Signal Quality Index (SQI).

Quoted 7 lines

Is this something you want to continually make available, or just as part of cable diagnostics. Additional nested attributes can be added to the cable test results structure, and the user space code just dumps whatever it finds. So it should be easy to have something like:

Pair A: OK
Pair A: Signal Quality Index class D

At least for automotive, avionics, (rockets till it is deployed :D) etc... the cable integrity will probably not change, except we have some sudden water infiltration into the cable, etc :)

However the SQI will probably change on a much shorter timescales, e.g. crosstalk from other T1 links or EMI from motors, radio transceivers, etc... We could sample this information during cable test, but also provide an interface to sample this information later during normal operation.

The NXP phy additionally offers the possibility to specify a warning threshold for the SQI, to generate a warning interrupt. There is a configurable fault threshold, too. However the spec doesn't mention this. If needed (in the future), polling for SQI in the kernel would be easier to implement if the PHY doesn't support interrupts.

According to the IEEE802.3bw paper we expect following noise sources:
================================================================================
a) Echo from the local transmitter on the same cable pair, is caused by the hybrid function for bidirectional data transmission in the BroadR-Reach duplex channel and by the impedance discontinuities in the link segment. Echo cancellation techniques, up to each PHY implementer, shall be used to achieve the objective BER level.

b) The typical background noise is mainly due to thermal noise. Thermal noise, with level roughly at -140 dBm/Hz, is not a critical contributor that would impact performance. BroadR- Reach signaling allows a robust margin over a 15m UTP channel to combat thermal noise.

c) There is no FEXT or NEXT as BroadR-Reach is a one pair solution. When multiple cable pairs are bundled, the alien XTALK (NEXT/FEXT) become interference sources. Since the transmitted symbols from the alien noise source in one cable are not available to another cable, cancellation cannot be done. When there are multiple pairs of UTP cables bundled together, where all pairs carry 100 Mb/s links, then each duplex link is disturbed by neighboring links, degrading the signal quality on the victim pair.
================================================================================

according to the "c", I would expect worst SQI as soon as communication will start on other bundled cable pairs.

When it comes to SQI the NXP data sheet and the opensig spec gives us:

https://www.nxp.com/docs/en/data-sheet/TJA1100.pdf

SQI=0 | worse then A | unstable link  |
SQI=1 | Class A      | unstable link  |
SQI=2 | Class B      | unstable link  |
SQI=3 | Class C      | good link      |
SQI=4 | Class D      | good link      | BER < 10^-10
SQI=5 | Class E      | good link      |
SQI=6 | Class F      | very good link |
SQI=7 | Class G      | very good link |

http://www.opensig.org/download/document/218/Advanced_PHY_features_for_automotive_Ethernet_V1.0.pdf

SQI=0 |             < 18dB | 
SQI=1 | 18dB <= SNR < 19dB | BER > 10^-10
SQI=2 | 19dB <= SNR < 20dB |
------+--------------------+--------------
SQI=3 | 20dB <= SNR < 21dB |
SQI=4 | 21dB <= SNR < 22dB | BER < 10^-10
SQI=5 | 22dB <= SNR < 23dB |
SQI=6 | 23dB <= SNR < 24dB |
SQI=7 | 24dB <= SNR        |

So I think we should pass raw SQI value to user space, at least in the first implementation.

What do you think about this?

Quoted 6 lines

Are the classes part of the Open Alliance specification? Ideally we want to report something standardized, not something proprietary to NXP.

Andrew

Signature · 4 lines
Pengutronix e.K.                           |                             |
Steuerwalder Str. 21                       | http://www.pengutronix.de/  |
31137 Hildesheim, Germany                  | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |
#3 lore raw
Quoted 6 lines · Oleksij Rempel
Quoted 2 lines

Pair A: OK
Pair A: Signal Quality Index class D

At least for automotive, avionics, (rockets till it is deployed :D) etc... the cable integrity will probably not change, except we have some sudden water infiltration into the cable, etc :)

As some of our applications are running on agricultural equipment, water in the cable is not completely implausible :-)

rsc

Signature · 4 lines
Pengutronix e.K.                           | Dipl.-Ing. Robert Schwebel  |
Steuerwalder Str. 21                       | https://www.pengutronix.de/ |
31137 Hildesheim, Germany                  | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-9    |
#4 lore raw
In reply to Oleksij Rempel
Quoted 4 lines · Oleksij Rempel

So I think we should pass raw SQI value to user space, at least in the first implementation.

What do you think about this?

Hi Oleksij,

I had a check about the background of this SQI thing. The table you reference with concrete SNR values is informative only and not a requirement. The requirements are rather loose.

This is from OA:
- Only for SQI=0 a link loss shall occur.
- The indicated signal quality shall monotonic increasing /decreasing with noise level.
- It shall be indicated in the datasheet at which level a BER<10^-10 (better than 10^-10) is achieved (e.g. "from SQI=3 to SQI=7 the link has a BER<10^-10 (better than 10^-10)")

I.e. SQI does not need to have a direct correlation with SNR. The fundamental underlying metric is the BER.
You can report the raw SQI level and users would have to look up what it means in the respective data sheet. There is no guaranteed relation between SQI levels of different devices, i.e. SQI 5 can have lower BER than SQI 6 on another device. Alternatively, you could report BER < x for the different SQI levels. However, this requires the information to be available. While I could provide these for NXP, it might not be easily available for other vendors. If reporting raw SQI, at least the SQI level for BER<10^-10 should be presented to give any meaning to the value.

Regards,

Christian

#5 lore raw

Hi Christian,

Quoted 16 lines · Christian Herber
Quoted 4 lines · Oleksij Rempel

So I think we should pass raw SQI value to user space, at least in the first implementation.

What do you think about this?

Hi Oleksij,

I had a check about the background of this SQI thing. The table you reference with concrete SNR values is informative only and not a requirement. The requirements are rather loose.

This is from OA:
- Only for SQI=0 a link loss shall occur.
- The indicated signal quality shall monotonic increasing /decreasing with noise level.
- It shall be indicated in the datasheet at which level a BER<10^-10 (better than 10^-10) is achieved (e.g. "from SQI=3 to SQI=7 the link has a BER<10^-10 (better than 10^-10)")

Quoted 4 lines

I.e. SQI does not need to have a direct correlation with SNR. The fundamental underlying metric is the BER.
You can report the raw SQI level and users would have to look up what it means in the respective data sheet. There is no guaranteed relation between SQI levels of different devices, i.e. SQI 5 can have lower BER than SQI 6 on another device. Alternatively, you could report BER < x for the different SQI levels. However, this requires the information to be available. While I could provide these for NXP, it might not be easily available for other vendors. If reporting raw SQI, at least the SQI level for BER<10^-10 should be presented to give any meaning to the value.

So the question is, which values to provide via KAPI to user space?

- SQI
The PHY can probably measure the SNR quite fast and has some internal function or lookup table to deduct the SQI from the measured SNR.

If I understand you correctly, we can only compare SQI values of the same PHY, as different PHYs give different SQIs for the same link characteristics (=SNR).
- SNR range
We read the SQI from the PHY look up the SNR range for that value from the data sheet and provide that value to use space. This gives a better description of the quality of the link.
- "guestimated" BER
The manufacturer of the PHY has probably done some extensive testing that a measured SNR can be correlated to some BER. This value may be provided in the data sheet, too.

The SNR seems to be most universal value, when it comes to comparing different situations (different links and different PHYs). The resolution of BER is not that detailed, for the NXP PHY is says only "BER below 1e-10" or not.

Quoted 2 lines

While I could provide these for NXP, it might not be easily available for other vendors.

It will be great if you can provide this information. It may force other vendors to do the same :)

The actual procedure to measure the BER is the following testing strategy suggested by opensig[1]:
--------------------------------------------------------------------------------
Procedure:
1. Configure the DUT as MASTER.
2. Connect the packet monitoring station to the automotive cable.
3. Connect the DUT to the automotive cable.
4. Send 2,470,000 1,518-byte packets (for a 10 -10 BER) and the monitor will count the number of packet errors.
5. Repeat step 4 for the remaining automotive cables.
6. Repeat steps 4-5 with the DUT configured as SLAVE.
--------------------------------------------------------------------------------

[1] http://www.opensig.org/download/document/225/Open_Alliance_100BASE-T1_PMA_Test_Suite_v1.0-dec.pdf

Regards,
Oleksij & Marc

Signature · 4 lines
Pengutronix e.K.                           |                             |
Steuerwalder Str. 21                       | http://www.pengutronix.de/  |
31137 Hildesheim, Germany                  | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |
#6 lore raw
In reply to Oleksij Rempel
Quoted 18 lines · Oleksij Rempel

I continue to work on TJA11xx PHY and need to export some additional cable diagnostic/link stability information: Signal Quality Index (SQI). The PHY data sheet describes it as following [1]:
================================================================================
6.10.3 Link stability

The signal-to-noise ratio is the parameter used to estimate link stability. The PMA Receive function monitors the signal-to-noise ratio continuously. Once the signal-to-noise ratio falls below a configurable threshold (SQI_FAILLIMIT), the link status is set to FAIL and communication is interrupted. The TJA1100 allows for adjusting the sensitivity of the PMA Receive function by configuring this threshold. The microcontroller can always check the current value of the signal-to-noise ratio via the SMI, allowing it to track a possible degradation in link stability.
================================================================================

Quoted 6 lines

Since this functionality is present at least on TJA11xx PHYs and mandatory according to Open Alliance[2], I hope this functionality is present on other 100/1000Base-T1 PHYs. So may be some common abstraction is possible. What would be the best place to provide it for the user space? According to the [2] SQI, is the part of Dynamic Channel Quality (DCQ) together with Mean Square Error (MSE) and Peak MSE value (pMSE).

IIUC these would be read-only parameters describing current state of the link which can be queried at any time. If this is the case, adding them as attributes to ETHTOOL_MSG_LINKSTATE_GET_REPLY message seems most fitting.

As for getting / setting the threshold, perhaps ETHTOOL_MSG_LINKINFO_GET and ETHTOOL_MSG_LINKINFO_SET. Unless you expect more configurable parameters like this in which case we may want to consider adding new request type (e.g. link params or link management).

Michal

#7 lore raw
Quoted 26 lines · Michal Kubecek
Quoted 18 lines · Oleksij Rempel

I continue to work on TJA11xx PHY and need to export some additional cable diagnostic/link stability information: Signal Quality Index (SQI). The PHY data sheet describes it as following [1]:
================================================================================
6.10.3 Link stability

The signal-to-noise ratio is the parameter used to estimate link stability. The PMA Receive function monitors the signal-to-noise ratio continuously. Once the signal-to-noise ratio falls below a configurable threshold (SQI_FAILLIMIT), the link status is set to FAIL and communication is interrupted. The TJA1100 allows for adjusting the sensitivity of the PMA Receive function by configuring this threshold. The microcontroller can always check the current value of the signal-to-noise ratio via the SMI, allowing it to track a possible degradation in link stability.
================================================================================

Quoted 6 lines

Since this functionality is present at least on TJA11xx PHYs and mandatory according to Open Alliance[2], I hope this functionality is present on other 100/1000Base-T1 PHYs. So may be some common abstraction is possible. What would be the best place to provide it for the user space? According to the [2] SQI, is the part of Dynamic Channel Quality (DCQ) together with Mean Square Error (MSE) and Peak MSE value (pMSE).

Quoted 4 lines

IIUC these would be read-only parameters describing current state of the link which can be queried at any time. If this is the case, adding them as attributes to ETHTOOL_MSG_LINKSTATE_GET_REPLY message seems most fitting.

ok

Quoted 4 lines

As for getting / setting the threshold, perhaps ETHTOOL_MSG_LINKINFO_GET and ETHTOOL_MSG_LINKINFO_SET. Unless you expect more configurable parameters like this in which case we may want to consider adding new request type (e.g. link params or link management).

Currently in my short term todo are:
- SQI
- PHY undervoltage
- PHY overtemerature

So far, I have no idea for PHY health diagnostic.

If we consider at least the mandatory properties listed in the opensig, then we would get following list:

- DCQ (dynamic channel group)
- SQI (Signal Quality Index)
- HDD (Harness defect detection group)
- OS (Open/Short detection) ----------------- implemented, cable test request.
- LQ (Link Quality)
- LTT (Link-training time. The time of the last link training)
- LFL (Link Failures and Losses. Number of link losses since the last power cycle)
- COM (communication ready) ----------------- implemented?
- POL (Polarity detection & correction)
- DET (Polarity detect)

I personally would add RE_ERR counter in this list as well.

Probably some one, soon or later, will try to implement them.

If I see it correctly, some of this properties are already implemented within other request types. Is it worth to a add a new request type for the rest of them?

Regards,
Oleksij

Signature · 4 lines
Pengutronix e.K.                           |                             |
Steuerwalder Str. 21                       | http://www.pengutronix.de/  |
31137 Hildesheim, Germany                  | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |
#8 lore raw
Quoted 11 lines
Quoted 4 lines

As for getting / setting the threshold, perhaps ETHTOOL_MSG_LINKINFO_GET and ETHTOOL_MSG_LINKINFO_SET. Unless you expect more configurable parameters like this in which case we may want to consider adding new request type (e.g. link params or link management).

Currently in my short term todo are:
- SQI

- PHY undervoltage
- PHY overtemerature

Do you only have alarms? Or are current values available for voltage and temperature?

Both of these would fit hwmon. It even has the option to set the alarm thresholds. The advantage of hwmon is that they are then just more sensors. You could even include the temperature sensor into a thermal zone to influence cooling. There are a couple of PHYs which already do hwmon, so there is code you can copy.

Quoted 5 lines

So far, I have no idea for PHY health diagnostic.

If we consider at least the mandatory properties listed in the opensig, then we would get following list:

Quoted 12 lines

- DCQ (dynamic channel group)
- SQI (Signal Quality Index)
- HDD (Harness defect detection group)
- OS (Open/Short detection) ----------------- implemented, cable test request.
- LQ (Link Quality)
- LTT (Link-training time. The time of the last link training)
- LFL (Link Failures and Losses. Number of link losses since the last power cycle)
- COM (communication ready) ----------------- implemented?
- POL (Polarity detection & correction)
- DET (Polarity detect)

Voltage and temperature are about the package. These are about the link. So they better fit ETHTOOL_MSG_LINKINFO_SET or similar.

It sounds like LFL are statistic counters? PHYs can have their own counters, which ethtool -S will return.

Does POLL somehow map to MDI MDIX? I guess not, since this is a T1.

Andrew

#9 lore raw
Quoted 15 lines · Andrew Lunn
Quoted 11 lines
Quoted 4 lines

As for getting / setting the threshold, perhaps ETHTOOL_MSG_LINKINFO_GET and ETHTOOL_MSG_LINKINFO_SET. Unless you expect more configurable parameters like this in which case we may want to consider adding new request type (e.g. link params or link management).

Currently in my short term todo are:
- SQI

- PHY undervoltage
- PHY overtemerature

Do you only have alarms? Or are current values available for voltage and temperature?

Quoted 6 lines

Both of these would fit hwmon. It even has the option to set the alarm thresholds. The advantage of hwmon is that they are then just more

sensors. You could even include the temperature sensor into a thermal zone to influence cooling. There are a couple of PHYs which already do hwmon, so there is code you can copy.

Yes, hwmon can do a lot of stuff. OTOH figuring out "what hwmon device corresponds to what network device is going to be tricky, and Im not sure if we want utilities like mii-tool to start using hwmon interfaces...

Best regards,
Pavel

Signature · 2 lines
(english) http://www.livejournal.com/~pavelmachek
(cesky, pictures) http://atrey.karlin.mff.cuni.cz/~pavel/picture/horses/blog.html
#10 lore raw

PHYs with advanced cable diagnostic support

In reply to Andrew Lunn

Hi Andrew,

I was looking for PHYs with more advanced cable testing support and information how it should be done properly.

So far I found this links:

A general information with some interesting examples:
https://www.ti.com/lit/an/slyt755/slyt755.pdf

A PHY with the impulse amplitude and times storage, for multiple impulses:
http://www.ti.com/lit/ds/symlink/dp83867cr.pdf
--------------------------------------------------------------------------------
TDR measurement is allowed in the DP83867 in the following scenarios:
* While Link partner is disconnected - cable is unplugged at the other side
* Link partner is connected but remains quiet (for example,in power-down mode)
* TDR could be automatically activated when the link fails or is dropped by setting bit 7 of register 0x0009(CFG1). The results of the TDR run after the link fails are saved in the TDR registers.
--------------------------------------------------------------------------------

It has following configuration bits:
- TDR AUTO RUN: Automatic TDR on Link Down (can be done is software for all PHYs)
- TDR_AVG_NUM: number Of TDR Cycles (is it good to know, how many TDR cycle we do?)
- TDR_CYCLE_TIME: Set the time for each TDR cycle (is it needed to sample only nearest damage? Probably this well need an UAPI for this)

Making an automatic cable test on the link drop seems to be an interesting idea. May be we should do it for all PHY with cable test support?

Regards,
Oleksij