Raw PHY TDR data
Subsystems (6)
Andrew Lunn
maintainerv3 cover Raw PHY TDR data
Some ethernet PHYs allow access to raw TDR data in addition to summary diagnostics information. Add support for retrieving this data via netlink ethtool. The basic structure in the core is the same as for normal phy diagnostics, the PHY driver simply uses different helpers to fill the netlink message with different data.
There is a graphical tool under development, as well a ethtool(1) which can dump the data as text and JSON.
A patched ethtool(1) can be found in
https://github.com/lunn/ethtool.git feature/cable-test-v5
Thanks for Chris Healy for lots of testing.
v2:
See the individual patches but:
Pass distances in centimeters, not meters
Allow the PHY to round distances to what it supports and report what it actually used along with the results.
Make the Marvell PHY use steps a multiple of 0.805 meters, its native step size.
v3:
Move the TDR configuration into a structure
Add a range check on step
Use NL_SET_ERR_MSG_ATTR() when appropriate
Move TDR configuration into a nest
Document attributes in the request
Unsquash the last two patches
Andrew Lunn (7):
net: ethtool: Add attributes for cable test TDR data
net: ethtool: Add generic parts of cable test TDR
net: ethtool: Add helpers for cable test TDR data
net: phy: marvell: Add support for amplitude graph
net: ethtool: Allow PHY cable test TDR data to configured net : phy: marvell: Speedup TDR data retrieval by only changing page
once
net: phy: marvell: Configure TDR pulse based on measurement length
Documentation/networking/ethtool-netlink.rst | 97 +++++++ drivers/net/phy/marvell.c | 285 ++++++++++++++++++- drivers/net/phy/nxp-tja11xx.c | 2 +- drivers/net/phy/phy.c | 66 ++++- include/linux/ethtool_netlink.h | 25 +- include/linux/phy.h | 28 ++ include/uapi/linux/ethtool_netlink.h | 76 +++++ net/ethtool/cabletest.c | 246 +++++++++++++++- net/ethtool/netlink.c | 5 + net/ethtool/netlink.h | 1 + 10 files changed, 818 insertions(+), 13 deletions(-)
Signature · 1 line
2.27.0.rc0
Andrew Lunn
maintainerPATCH v3 1/7 net: ethtool: Add attributes for cable test TDR data
Some Ethernet PHYs can return the raw time domain reflectromatry data. Add the attributes to allow this data to be requested and returned via netlink ethtool.
v2:
m -> cm
Report what the PHY actually used for start/stop/step.
--- Documentation/networking/ethtool-netlink.rst | 81 ++++++++++++++++++++ include/uapi/linux/ethtool_netlink.h | 63 +++++++++++++++ 2 files changed, 144 insertions(+)
Documentation/networking/ethtool-netlink.rst +81 -0
@@ -205,6 +205,7 @@ Userspace to kernel: ``ETHTOOL_MSG_EEE_SET`` set EEE settings ``ETHTOOL_MSG_TSINFO_GET`` get timestamping info ``ETHTOOL_MSG_CABLE_TEST_ACT`` action start cable test + ``ETHTOOL_MSG_CABLE_TEST_TDR_ACT`` action start raw TDR cable test ===================================== ================================ Kernel to userspace:
@@ -237,6 +238,7 @@ Kernel to userspace: ``ETHTOOL_MSG_EEE_NTF`` EEE settings ``ETHTOOL_MSG_TSINFO_GET_REPLY`` timestamping info ``ETHTOOL_MSG_CABLE_TEST_NTF`` Cable test results + ``ETHTOOL_MSG_CABLE_TEST_TDR_NTF`` Cable test TDR results ===================================== ================================= ``GET`` requests are sent by userspace applications to retrieve device
@@ -1014,6 +1016,84 @@ information. | | | ``ETHTOOL_A_CABLE_FAULT_LENGTH_CM`` | u32 | length in cm | +-+-+-----------------------------------------+--------+---------------------+ +CABLE_TEST TDR +============== + +Start a cable test and report raw TDR data + +Request contents: + + ==================================== ====== ========================== + ``ETHTOOL_A_CABLE_TEST_TDR_HEADER`` nested request header + ==================================== ====== ========================== + +Notification contents: + +Raw TDR data is gathered by sending a pulse down the cable and +recording the amplitude of the reflected pulse for a given distance. + +It can take a number of seconds to collect TDR data, especial if the +full 100 meters is probed at 1 meter intervals. When the test is +started a notification will be sent containing just +ETHTOOL_A_CABLE_TEST_TDR_STATUS with the value +ETHTOOL_A_CABLE_TEST_NTF_STATUS_STARTED. + +When the test has completed a second notification will be sent +containing ETHTOOL_A_CABLE_TEST_TDR_STATUS with the value +ETHTOOL_A_CABLE_TEST_NTF_STATUS_COMPLETED and the TDR data. + +The message may optionally contain the amplitude of the pulse send +down the cable. This is measured in mV. A reflection should not be +bigger than transmitted pulse. + +Before the raw TDR data should be an ETHTOOL_A_CABLE_TDR_NEST_STEP +nest containing information about the distance along the cable for the +first reading, the last reading, and the step between each +reading. Distances are measured in centimeters. These should be the +exact values the PHY used. These may be different to what the user +requested, if the native measurement resolution is greater than 1 cm. + +For each step along the cable, a ETHTOOL_A_CABLE_TDR_NEST_AMPLITUDE is +used to report the amplitude of the reflection for a given pair. + + +---------------------------------------------+--------+----------------------+ + | ``ETHTOOL_A_CABLE_TEST_TDR_HEADER`` | nested | reply header | + +---------------------------------------------+--------+----------------------+ + | ``ETHTOOL_A_CABLE_TEST_TDR_STATUS`` | u8 | completed | + +---------------------------------------------+--------+----------------------+ + | ``ETHTOOL_A_CABLE_TEST_TDR_NTF_NEST`` | nested | all the results | + +-+-------------------------------------------+--------+----------------------+ + | | ``ETHTOOL_A_CABLE_TDR_NEST_PULSE`` | nested | TX Pulse amplitude | + +-+-+-----------------------------------------+--------+----------------------+ + | | | ``ETHTOOL_A_CABLE_PULSE_mV`` | s16 | Pulse amplitude | + +-+-+-----------------------------------------+--------+----------------------+ + | | ``ETHTOOL_A_CABLE_NEST_STEP`` | nested | TDR step info | + +-+-+-----------------------------------------+--------+----------------------+ + | | | ``ETHTOOL_A_CABLE_STEP_FIRST_DISTANCE ``| u32 | First data distance | + +-+-+-----------------------------------------+--------+----------------------+ + | | | ``ETHTOOL_A_CABLE_STEP_LAST_DISTANCE `` | u32 | Last data distance | + +-+-+-----------------------------------------+--------+----------------------+ + | | | ``ETHTOOL_A_CABLE_STEP_STEP_DISTANCE `` | u32 | distance of each step| + +-+-+-----------------------------------------+--------+----------------------+ + | | ``ETHTOOL_A_CABLE_TDR_NEST_AMPLITUDE`` | nested | Reflection amplitude | + +-+-+-----------------------------------------+--------+----------------------+ + | | | ``ETHTOOL_A_CABLE_RESULTS_PAIR`` | u8 | pair number | + +-+-+-----------------------------------------+--------+----------------------+ + | | | ``ETHTOOL_A_CABLE_AMPLITUDE_mV`` | s16 | Reflection amplitude | + +-+-+-----------------------------------------+--------+----------------------+ + | | ``ETHTOOL_A_CABLE_TDR_NEST_AMPLITUDE`` | nested | Reflection amplitude | + +-+-+-----------------------------------------+--------+----------------------+ + | | | ``ETHTOOL_A_CABLE_RESULTS_PAIR`` | u8 | pair number | + +-+-+-----------------------------------------+--------+----------------------+ + | | | ``ETHTOOL_A_CABLE_AMPLITUDE_mV`` | s16 | Reflection amplitude | + +-+-+-----------------------------------------+--------+----------------------+ + | | ``ETHTOOL_A_CABLE_TDR_NEST_AMPLITUDE`` | nested | Reflection amplitude | + +-+-+-----------------------------------------+--------+----------------------+ + | | | ``ETHTOOL_A_CABLE_RESULTS_PAIR`` | u8 | pair number | + +-+-+-----------------------------------------+--------+----------------------+ + | | | ``ETHTOOL_A_CABLE_AMPLITUDE_mV`` | s16 | Reflection amplitude | + +-+-+-----------------------------------------+--------+----------------------+ + Request translation ===================
@@ -1110,4 +1190,5 @@ are netlink only. ``ETHTOOL_GFECPARAM`` n/a ``ETHTOOL_SFECPARAM`` n/a n/a ''ETHTOOL_MSG_CABLE_TEST_ACT'' + n/a ''ETHTOOL_MSG_CABLE_TEST_TDR_ACT'' =================================== =====================================
include/uapi/linux/ethtool_netlink.h +63 -0
81 lines not on this page · raw message
Signature · 1 line
2.27.0.rc0
Andrew Lunn
maintainerPATCH v3 2/7 net: ethtool: Add generic parts of cable test TDR
In reply to Andrew LunnAdd the generic parts of the code used to trigger a cable test and return raw TDR data. Any PHY driver which support this must implement the new driver op.
v2
Update nxp-tja11xx for API change.
--- drivers/net/phy/nxp-tja11xx.c | 2 +- drivers/net/phy/phy.c | 65 ++++++++++++++++++++++++++++++++- include/linux/ethtool_netlink.h | 4 +- include/linux/phy.h | 13 +++++++ net/ethtool/cabletest.c | 65 ++++++++++++++++++++++++++++++--- net/ethtool/netlink.c | 5 +++ net/ethtool/netlink.h | 1 + 7 files changed, 145 insertions(+), 10 deletions(-)
drivers/net/phy/nxp-tja11xx.c +1 -1
@@ -194,7 +194,7 @@ static int tja11xx_config_aneg_cable_test(struct phy_device *phydev) !phydev->drv->cable_test_get_status)return 0 ; - ret =ethnl_cable_test_alloc (phydev); + ret =ethnl_cable_test_alloc (phydev,ETHTOOL_MSG_CABLE_TEST_NTF );if (ret)return ret;
drivers/net/phy/phy.c +64 -1
77 lines not on this page · raw message
include/linux/ethtool_netlink.h +2 -2
@@ -17,13 +17,13 @@ enum ethtool_multicast_groups {struct phy_device ;#if IS_ENABLED (CONFIG_ETHTOOL_NETLINK ) -int ethnl_cable_test_alloc (struct phy_device *phydev); +int ethnl_cable_test_alloc (struct phy_device *phydev,u8 cmd);void ethnl_cable_test_free (struct phy_device *phydev);void ethnl_cable_test_finished (struct phy_device *phydev);int ethnl_cable_test_result (struct phy_device *phydev,u8 pair,u8 result);int ethnl_cable_test_fault_length (struct phy_device *phydev,u8 pair,u32 cm);#else -static inline int ethnl_cable_test_alloc (struct phy_device *phydev) +static inline int ethnl_cable_test_alloc (struct phy_device *phydev,u8 cmd) {return -EOPNOTSUPP ; }
include/linux/phy.h +13 -0
@@ -705,6 +705,10 @@ struct phy_driver {/* Start a cable test */ int (*cable_test_start)(struct phy_device *dev); + +/* Start a raw TDR cable test */ +int (*cable_test_tdr_start)(struct phy_device *dev); +/* Once per second, or on interrupt, request the status of the * test. */
@@ -1257,6 +1261,8 @@ int phy_reset_after_clk_enable(struct phy_device *phydev);#if IS_ENABLED (CONFIG_PHYLIB )int phy_start_cable_test (struct phy_device *phydev,struct netlink_ext_ack *extack); +int phy_start_cable_test_tdr (struct phy_device *phydev, +struct netlink_ext_ack *extack);#else static inline int phy_start_cable_test(struct phy_device *phydev,
@@ -1265,6 +1271,13 @@ int phy_start_cable_test(struct phy_device *phydev,NL_SET_ERR_MSG (extack,"Kernel not compiled with PHYLIB support" ); return -EOPNOTSUPP; } +static inline +int phy_start_cable_test_tdr (struct phy_device *phydev, +struct netlink_ext_ack *extack) +{ +NL_SET_ERR_MSG (extack,"Kernel not compiled with PHYLIB support" ); +return -EOPNOTSUPP ; +}#endif int phy_cable_test_result (struct phy_device *phydev,u8 pair,u16 result);
net/ethtool/cabletest.c +59 -6
98 lines not on this page · raw message
net/ethtool/netlink.c +5 -0
@@ -844,6 +844,11 @@ static const struct genl_ops ethtool_genl_ops[] = { .flags = GENL_UNS_ADMIN_PERM, .doit = ethnl_act_cable_test, }, + { + .cmd = ETHTOOL_MSG_CABLE_TEST_TDR_ACT, + .flags = GENL_UNS_ADMIN_PERM, + .doit = ethnl_act_cable_test_tdr, + }, };static const struct genl_multicast_group ethtool_nl_mcgrps[] = {
net/ethtool/netlink.h +1 -0
@@ -360,5 +360,6 @@ int ethnl_set_coalesce(struct sk_buff *skb, struct genl_info *info);int ethnl_set_pause (struct sk_buff *skb,struct genl_info *info);int ethnl_set_eee (struct sk_buff *skb,struct genl_info *info);int ethnl_act_cable_test (struct sk_buff *skb,struct genl_info *info); +int ethnl_act_cable_test_tdr (struct sk_buff *skb,struct genl_info *info);#endif /* _NET_ETHTOOL_NETLINK_H */
Signature · 1 line
2.27.0.rc0
Andrew Lunn
maintainerPATCH v3 3/7 net: ethtool: Add helpers for cable test TDR data
In reply to Andrew LunnAdd helpers for returning raw TDR helpers in netlink messages.
--- include/linux/ethtool_netlink.h | 21 +++++++++ net/ethtool/cabletest.c | 79 ++++++++++++++++++++++++++++++++- 2 files changed, 99 insertions(+), 1 deletion(-)
include/linux/ethtool_netlink.h +21 -0
@@ -22,6 +22,10 @@ void ethnl_cable_test_free(struct phy_device *phydev);void ethnl_cable_test_finished (struct phy_device *phydev);int ethnl_cable_test_result (struct phy_device *phydev,u8 pair,u8 result);int ethnl_cable_test_fault_length (struct phy_device *phydev,u8 pair,u32 cm); +int ethnl_cable_test_amplitude (struct phy_device *phydev,u8 pair,s16 mV); +int ethnl_cable_test_pulse (struct phy_device *phydev,u16 mV); +int ethnl_cable_test_step (struct phy_device *phydev,u32 first,u32 last, +u32 step);#else static inline int ethnl_cable_test_alloc (struct phy_device *phydev,u8 cmd) {
@@ -46,5 +50,22 @@ static inline int ethnl_cable_test_fault_length(struct phy_device *phydev, {return -EOPNOTSUPP ; } + +static inline int ethnl_cable_test_amplitude (struct phy_device *phydev, +u8 pair,s16 mV) +{ +return -EOPNOTSUPP ; +} + +static inline int ethnl_cable_test_pulse (struct phy_device *phydev,u16 mV) +{ +return -EOPNOTSUPP ; +} + +static inline int ethnl_cable_test_step (struct phy_device *phydev,u32 first, +u32 last,u32 step) +{ +return -EOPNOTSUPP ; +}#endif /* IS_ENABLED(ETHTOOL_NETLINK) */ #endif /* _LINUX_ETHTOOL_NETLINK_H_ */
net/ethtool/cabletest.c +78 -1
88 lines not on this page · raw message
Signature · 1 line
2.27.0.rc0
Andrew Lunn
maintainerPATCH v3 4/7 net: phy: marvell: Add support for amplitude graph
In reply to Andrew LunnThe Marvell PHYs can measure the amplitude of the returned signal for a given distance. Implement this option of the cable test infrastructure. When reporting the step, convert the distance into cm.
v2:
Step based on the measurement resolution, and convert this to cm.
--- drivers/net/phy/marvell.c | 232 +++++++++++++++++++++++++++++++++++++- 1 file changed, 231 insertions(+), 1 deletion(-)
drivers/net/phy/marvell.c +231 -1
@@ -42,6 +42,7 @@#define MII_MARVELL_FIBER_PAGE 0x01#define MII_MARVELL_MSCR_PAGE 0x02#define MII_MARVELL_LED_PAGE 0x03 +#define MII_MARVELL_VCT5_PAGE 0x05#define MII_MARVELL_MISC_TEST_PAGE 0x06#define MII_MARVELL_VCT7_PAGE 0x07#define MII_MARVELL_WOL_PAGE 0x11
@@ -164,6 +165,54 @@#define MII_88E1510_GEN_CTRL_REG_1_MODE_SGMII 0x1/* SGMII to copper */ #define MII_88E1510_GEN_CTRL_REG_1_RESET 0x8000/* Soft reset */ +#define MII_VCT5_TX_RX_MDI0_COUPLING 0x10 +#define MII_VCT5_TX_RX_MDI1_COUPLING 0x11 +#define MII_VCT5_TX_RX_MDI2_COUPLING 0x12 +#define MII_VCT5_TX_RX_MDI3_COUPLING 0x13 +#define MII_VCT5_TX_RX_AMPLITUDE_MASK 0x7f00 +#define MII_VCT5_TX_RX_AMPLITUDE_SHIFT 8 +#define MII_VCT5_TX_RX_COUPLING_POSITIVE_REFLECTION BIT(15) + +#define MII_VCT5_CTRL 0x17 +#define MII_VCT5_CTRL_ENABLE BIT(15) +#define MII_VCT5_CTRL_COMPLETE BIT(14) +#define MII_VCT5_CTRL_TX_SAME_CHANNEL (0x0 << 11) +#define MII_VCT5_CTRL_TX0_CHANNEL (0x4 << 11) +#define MII_VCT5_CTRL_TX1_CHANNEL (0x5 << 11) +#define MII_VCT5_CTRL_TX2_CHANNEL (0x6 << 11) +#define MII_VCT5_CTRL_TX3_CHANNEL (0x7 << 11) +#define MII_VCT5_CTRL_SAMPLES_2 (0x0 << 8) +#define MII_VCT5_CTRL_SAMPLES_4 (0x1 << 8) +#define MII_VCT5_CTRL_SAMPLES_8 (0x2 << 8) +#define MII_VCT5_CTRL_SAMPLES_16 (0x3 << 8) +#define MII_VCT5_CTRL_SAMPLES_32 (0x4 << 8) +#define MII_VCT5_CTRL_SAMPLES_64 (0x5 << 8) +#define MII_VCT5_CTRL_SAMPLES_128 (0x6 << 8) +#define MII_VCT5_CTRL_SAMPLES_DEFAULT (0x6 << 8) +#define MII_VCT5_CTRL_SAMPLES_256 (0x7 << 8) +#define MII_VCT5_CTRL_SAMPLES_SHIFT 8 +#define MII_VCT5_CTRL_MODE_MAXIMUM_PEEK (0x0 << 6) +#define MII_VCT5_CTRL_MODE_FIRST_LAST_PEEK (0x1 << 6) +#define MII_VCT5_CTRL_MODE_OFFSET (0x2 << 6) +#define MII_VCT5_CTRL_SAMPLE_POINT (0x3 << 6) +#define MII_VCT5_CTRL_PEEK_HYST_DEFAULT 3 + +#define MII_VCT5_SAMPLE_POINT_DISTANCE 0x18 +#define MII_VCT5_TX_PULSE_CTRL 0x1c +#define MII_VCT5_TX_PULSE_CTRL_DONT_WAIT_LINK_DOWN BIT(12) +#define MII_VCT5_TX_PULSE_CTRL_PULSE_WIDTH_128nS (0x0 << 10) +#define MII_VCT5_TX_PULSE_CTRL_PULSE_WIDTH_96nS (0x1 << 10) +#define MII_VCT5_TX_PULSE_CTRL_PULSE_WIDTH_64nS (0x2 << 10) +#define MII_VCT5_TX_PULSE_CTRL_PULSE_WIDTH_32nS (0x3 << 10) +#define MII_VCT5_TX_PULSE_CTRL_PULSE_WIDTH_SHIFT 10 +#define MII_VCT5_TX_PULSE_CTRL_PULSE_AMPLITUDE_1000mV (0x0 << 8) +#define MII_VCT5_TX_PULSE_CTRL_PULSE_AMPLITUDE_750mV (0x1 << 8) +#define MII_VCT5_TX_PULSE_CTRL_PULSE_AMPLITUDE_500mV (0x2 << 8) +#define MII_VCT5_TX_PULSE_CTRL_PULSE_AMPLITUDE_250mV (0x3 << 8) +#define MII_VCT5_TX_PULSE_CTRL_PULSE_AMPLITUDE_SHIFT 8 +#define MII_VCT5_TX_PULSE_CTRL_MAX_AMP BIT(7) +#define MII_VCT5_TX_PULSE_CTRL_GT_140m_46_86mV (0x6 << 0) +#define MII_VCT7_PAIR_0_DISTANCE 0x10#define MII_VCT7_PAIR_1_DISTANCE 0x11#define MII_VCT7_PAIR_2_DISTANCE 0x12
@@ -220,6 +269,7 @@ struct marvell_priv {u64 stats[ARRAY_SIZE (marvell_hw_stats)];char *hwmon_name;struct device *hwmon_dev; +bool cable_test_tdr; };static int marvell_read_page (struct phy_device *phydev)
@@ -1690,7 +1740,119 @@ static void marvell_get_stats(struct phy_device *phydev, data[i] =marvell_get_stat (phydev, i); } -static int marvell_vct7_cable_test_start (struct phy_device *phydev) +static int marvell_vct5_wait_complete (struct phy_device *phydev) +{ +int i; +int val; + +for (i =0 ; i <32 ; i++) { + val =phy_read_paged (phydev,MII_MARVELL_VCT5_PAGE , +MII_VCT5_CTRL ); +if (val <0 ) +return val; + +if (val &MII_VCT5_CTRL_COMPLETE ) +return 0 ; + +usleep_range (1000 ,2000 ); + } + +phydev_err (phydev,"Timeout while waiting for cable test to finish\n" ); +return -ETIMEDOUT ; +} + +static int marvell_vct5_amplitude (struct phy_device *phydev,int pair) +{ +int amplitude; +int val; +int reg; + + reg =MII_VCT5_TX_RX_MDI0_COUPLING + pair; + val =phy_read_paged (phydev,MII_MARVELL_VCT5_PAGE , reg); + +if (val <0 ) +return 0 ; + + amplitude = (val &MII_VCT5_TX_RX_AMPLITUDE_MASK ) >> +MII_VCT5_TX_RX_AMPLITUDE_SHIFT ; + +if (!(val &MII_VCT5_TX_RX_COUPLING_POSITIVE_REFLECTION )) + amplitude = -amplitude; + +return 1000 * amplitude /128 ; +} + +static u32 marvell_vct5_distance2cm (int distance) +{ +return distance *805 /10 ; +} + +static int marvell_vct5_amplitude_distance (struct phy_device *phydev, +int distance) +{ +int mV_pair0, mV_pair1, mV_pair2, mV_pair3; +u16 reg; +int err; + + err =phy_write_paged (phydev,MII_MARVELL_VCT5_PAGE , +MII_VCT5_SAMPLE_POINT_DISTANCE , + distance); +if (err) +return err; + + reg =MII_VCT5_CTRL_ENABLE | +MII_VCT5_CTRL_TX_SAME_CHANNEL | +MII_VCT5_CTRL_SAMPLES_DEFAULT | +MII_VCT5_CTRL_SAMPLE_POINT | +MII_VCT5_CTRL_PEEK_HYST_DEFAULT ; + err =phy_write_paged (phydev,MII_MARVELL_VCT5_PAGE , +MII_VCT5_CTRL , reg); +if (err) +return err; + + err =marvell_vct5_wait_complete (phydev); +if (err) +return err; + + mV_pair0 =marvell_vct5_amplitude (phydev,0 ); + mV_pair1 =marvell_vct5_amplitude (phydev,1 ); + mV_pair2 =marvell_vct5_amplitude (phydev,2 ); + mV_pair3 =marvell_vct5_amplitude (phydev,3 ); + +ethnl_cable_test_amplitude (phydev,ETHTOOL_A_CABLE_PAIR_A , mV_pair0); +ethnl_cable_test_amplitude (phydev,ETHTOOL_A_CABLE_PAIR_B , mV_pair1); +ethnl_cable_test_amplitude (phydev,ETHTOOL_A_CABLE_PAIR_C , mV_pair2); +ethnl_cable_test_amplitude (phydev,ETHTOOL_A_CABLE_PAIR_D , mV_pair3); + +return 0 ; +} + +static int marvell_vct5_amplitude_graph (struct phy_device *phydev) +{ +int distance; +int err; +u16 reg; + + reg = MII_VCT5_TX_PULSE_CTRL_GT_140m_46_86mV | +MII_VCT5_TX_PULSE_CTRL_DONT_WAIT_LINK_DOWN | +MII_VCT5_TX_PULSE_CTRL_MAX_AMP | + MII_VCT5_TX_PULSE_CTRL_PULSE_WIDTH_32nS; + + err =phy_write_paged (phydev,MII_MARVELL_VCT5_PAGE , +MII_VCT5_TX_PULSE_CTRL , reg); +if (err) +return err; + +for (distance =0 ; distance <=100 ; distance++) { + err =marvell_vct5_amplitude_distance (phydev, distance); +if (err) +return err; + } + +return 0 ; +} + +static int marvell_cable_test_start_common (struct phy_device *phydev) {int bmcr, bmsr, ret;
@@ -1719,12 +1881,69 @@ static int marvell_vct7_cable_test_start(struct phy_device *phydev)if (bmsr &BMSR_LSTATUS )msleep (1500 ); +return 0 ; +} + +static int marvell_vct7_cable_test_start (struct phy_device *phydev) +{ +struct marvell_priv *priv = phydev->priv; +int ret; + + ret =marvell_cable_test_start_common (phydev); +if (ret) +return ret; + + priv->cable_test_tdr = false; + +/* Reset the VCT5 API control to defaults, otherwise +* VCT7 does not work correctly. +*/ + ret =phy_write_paged (phydev,MII_MARVELL_VCT5_PAGE , +MII_VCT5_CTRL , +MII_VCT5_CTRL_TX_SAME_CHANNEL | +MII_VCT5_CTRL_SAMPLES_DEFAULT | +MII_VCT5_CTRL_MODE_MAXIMUM_PEEK | +MII_VCT5_CTRL_PEEK_HYST_DEFAULT ); +if (ret) +return ret; + + ret =phy_write_paged (phydev,MII_MARVELL_VCT5_PAGE , +MII_VCT5_SAMPLE_POINT_DISTANCE ,0 ); +if (ret) +return ret; +return phy_write_paged (phydev,MII_MARVELL_VCT7_PAGE ,MII_VCT7_CTRL ,MII_VCT7_CTRL_RUN_NOW |MII_VCT7_CTRL_CENTIMETERS ); } +static int marvell_vct5_cable_test_tdr_start (struct phy_device *phydev) +{ +struct marvell_priv *priv = phydev->priv; +int ret; + +/* Disable VCT7 */ + ret =phy_write_paged (phydev,MII_MARVELL_VCT7_PAGE , +MII_VCT7_CTRL ,0 ); +if (ret) +return ret; + + ret =marvell_cable_test_start_common (phydev); +if (ret) +return ret; + + priv->cable_test_tdr = true; + ret =ethnl_cable_test_pulse (phydev,1000 ); +if (ret) +return ret; + +return ethnl_cable_test_step (phydev, +marvell_vct5_distance2cm (0 ), +marvell_vct5_distance2cm (100 ), +marvell_vct5_distance2cm (1 )); +} +static int marvell_vct7_distance_to_length (int distance,bool meter) {if (meter)
@@ -1828,8 +2047,15 @@ static int marvell_vct7_cable_test_report(struct phy_device *phydev)static int marvell_vct7_cable_test_get_status (struct phy_device *phydev,bool *finished) { +struct marvell_priv *priv = phydev->priv;int ret; +if (priv->cable_test_tdr) { + ret =marvell_vct5_amplitude_graph (phydev); + *finished = true; +return ret; + } + *finished = false; ret = phy_read_paged(phydev, MII_MARVELL_VCT7_PAGE,
@@ -2563,6 +2789,7 @@ static struct phy_driver marvell_drivers[] = { .get_tunable = m88e1011_get_tunable, .set_tunable = m88e1011_set_tunable, .cable_test_start = marvell_vct7_cable_test_start, + .cable_test_tdr_start = marvell_vct5_cable_test_tdr_start, .cable_test_get_status = marvell_vct7_cable_test_get_status, }, {
@@ -2588,6 +2815,7 @@ static struct phy_driver marvell_drivers[] = { .get_tunable = m88e1540_get_tunable, .set_tunable = m88e1540_set_tunable, .cable_test_start = marvell_vct7_cable_test_start, + .cable_test_tdr_start = marvell_vct5_cable_test_tdr_start, .cable_test_get_status = marvell_vct7_cable_test_get_status, }, {
@@ -2613,6 +2841,7 @@ static struct phy_driver marvell_drivers[] = { .get_tunable = m88e1540_get_tunable, .set_tunable = m88e1540_set_tunable, .cable_test_start = marvell_vct7_cable_test_start, + .cable_test_tdr_start = marvell_vct5_cable_test_tdr_start, .cable_test_get_status = marvell_vct7_cable_test_get_status, }, {
@@ -2658,6 +2887,7 @@ static struct phy_driver marvell_drivers[] = { .get_tunable = m88e1540_get_tunable, .set_tunable = m88e1540_set_tunable, .cable_test_start = marvell_vct7_cable_test_start, + .cable_test_tdr_start = marvell_vct5_cable_test_tdr_start, .cable_test_get_status = marvell_vct7_cable_test_get_status, }, };
Signature · 1 line
2.27.0.rc0
Andrew Lunn
maintainerPATCH v3 5/7 net: ethtool: Allow PHY cable test TDR data to configured
In reply to Andrew LunnAllow the user to configure where on the cable the TDR data should be retrieved, in terms of first and last sample, and the step between samples. Also add the ability to ask for TDR data for just one pair.
If this configuration is not provided, it defaults to 1-150m at 1m intervals for all pairs.
v3:
Move the TDR configuration into a structure
Add a range check on step
Use NL_SET_ERR_MSG_ATTR() when appropriate
Move TDR configuration into a nest
Document attributes in the request
--- Documentation/networking/ethtool-netlink.rst | 22 +++- drivers/net/phy/marvell.c | 59 ++++++++--- drivers/net/phy/phy.c | 5 +- include/linux/phy.h | 21 +++- include/uapi/linux/ethtool_netlink.h | 13 +++ net/ethtool/cabletest.c | 104 ++++++++++++++++++- 6 files changed, 197 insertions(+), 27 deletions(-)
Documentation/networking/ethtool-netlink.rst +19 -3
@@ -1023,9 +1023,25 @@ Start a cable test and report raw TDR data Request contents: - ==================================== ====== ========================== - ``ETHTOOL_A_CABLE_TEST_TDR_HEADER`` nested request header - ==================================== ====== ========================== + +--------------------------------------------+--------+-----------------------+ + | ``ETHTOOL_A_CABLE_TEST_TDR_HEADER`` | nested | reply header | + +--------------------------------------------+--------+-----------------------+ + | ``ETHTOOL_A_CABLE_TEST_TDR_CFG`` | nested | test configuration | + +-+------------------------------------------+--------+-----------------------+ + | | ``ETHTOOL_A_CABLE_STEP_FIRST_DISTANCE `` | u32 | first data distance | + +-+-+----------------------------------------+--------+-----------------------+ + | | ``ETHTOOL_A_CABLE_STEP_LAST_DISTANCE `` | u32 | last data distance | + +-+-+----------------------------------------+--------+-----------------------+ + | | ``ETHTOOL_A_CABLE_STEP_STEP_DISTANCE `` | u32 | distance of each step | + +-+-+----------------------------------------+--------+-----------------------+ + | | ``ETHTOOL_A_CABLE_TEST_TDR_CFG_PAIR`` | u8 | pair to test | + +-+-+----------------------------------------+--------+-----------------------+ + +The ETHTOOL_A_CABLE_TEST_TDR_CFG is optional, as well as all members +of the nest. All distances are expressed in centimeters. The PHY takes +the distances as a guide, and rounds to the nearest distance it +actually supports. If a pair is passed, only that one pair will be +tested. Otherwise all pairs are tested. Notification contents:
drivers/net/phy/marvell.c +42 -17
121 lines not on this page · raw message
drivers/net/phy/phy.c +3 -2
@@ -553,7 +553,8 @@ int phy_start_cable_test(struct phy_device *phydev,EXPORT_SYMBOL (phy_start_cable_test);int phy_start_cable_test_tdr (struct phy_device *phydev, -struct netlink_ext_ack *extack) +struct netlink_ext_ack *extack, +const struct phy_tdr_config *config) {struct net_device *dev = phydev->attached_dev;int err = -ENOMEM ;
@@ -590,7 +591,7 @@ int phy_start_cable_test_tdr(struct phy_device *phydev,phy_link_down (phydev);netif_testing_on (dev); - err = phydev->drv->cable_test_tdr_start (phydev); + err = phydev->drv->cable_test_tdr_start (phydev, config);if (err) {netif_testing_off (dev);phy_link_up (phydev);
include/linux/phy.h +18 -3
@@ -554,6 +554,18 @@ struct phy_device {#define to_phy_device (d) container_of(to_mdio_device(d), \ struct phy_device, mdio) +/* A structure containing possible configuration parameters +* for a TDR cable test. The driver does not need to implement +* all the parameters, but should report what is actually used. +*/ +struct phy_tdr_config { +u32 first; +u32 last; +u32 step; +s8 pair; +}; +#define PHY_PAIR_ALL -1 +/* struct phy_driver: Driver structure for a particular PHY type * * driver_data: static driver data
@@ -707,7 +719,8 @@ struct phy_driver {int (*cable_test_start)(struct phy_device *dev);/* Start a raw TDR cable test */ -int (*cable_test_tdr_start)(struct phy_device *dev); +int (*cable_test_tdr_start)(struct phy_device *dev, +const struct phy_tdr_config *config);/* Once per second, or on interrupt, request the status of the * test.
@@ -1262,7 +1275,8 @@ int phy_reset_after_clk_enable(struct phy_device *phydev);int phy_start_cable_test (struct phy_device *phydev,struct netlink_ext_ack *extack);int phy_start_cable_test_tdr (struct phy_device *phydev, -struct netlink_ext_ack *extack); +struct netlink_ext_ack *extack, +const struct phy_tdr_config *config);#else static inline int phy_start_cable_test(struct phy_device *phydev,
@@ -1273,7 +1287,8 @@ int phy_start_cable_test(struct phy_device *phydev, }static inline int phy_start_cable_test_tdr (struct phy_device *phydev, -struct netlink_ext_ack *extack) +struct netlink_ext_ack *extack, +const struct phy_tdr_config *config) {NL_SET_ERR_MSG (extack,"Kernel not compiled with PHYLIB support" );return -EOPNOTSUPP ;
include/uapi/linux/ethtool_netlink.h +13 -0
@@ -482,9 +482,22 @@ enum {/* CABLE TEST TDR */ +enum { +ETHTOOL_A_CABLE_TEST_TDR_CFG_UNSPEC , +ETHTOOL_A_CABLE_TEST_TDR_CFG_FIRST ,/* u32 */ +ETHTOOL_A_CABLE_TEST_TDR_CFG_LAST ,/* u32 */ +ETHTOOL_A_CABLE_TEST_TDR_CFG_STEP ,/* u32 */ +ETHTOOL_A_CABLE_TEST_TDR_CFG_PAIR ,/* u8 */ + +/* add new constants above here */ + __ETHTOOL_A_CABLE_TEST_TDR_CFG_CNT, +ETHTOOL_A_CABLE_TEST_TDR_CFG_MAX = __ETHTOOL_A_CABLE_TEST_TDR_CFG_CNT -1 +}; +enum {ETHTOOL_A_CABLE_TEST_TDR_UNSPEC ,ETHTOOL_A_CABLE_TEST_TDR_HEADER ,/* nest - _A_HEADER_* */ +ETHTOOL_A_CABLE_TEST_TDR_CFG ,/* nest - *_TDR_CFG_* */ /* add new constants above here */ __ETHTOOL_A_CABLE_TEST_TDR_CNT,
net/ethtool/cabletest.c +102 -2
137 lines not on this page · raw message
Signature · 1 line
2.27.0.rc0
Andrew Lunn
maintainerPATCH v3 6/7 net : phy: marvell: Speedup TDR data retrieval by only changing page once
In reply to Andrew LunnGetting the TDR data requires a large number of MDIO bus transactions. The number can however be reduced if the page is only changed once. Add the needed locking to allow this, and make use of unlocked read/write methods where needed.
--- drivers/net/phy/marvell.c | 31 +++++++++++++++++++------------ 1 file changed, 19 insertions(+), 12 deletions(-)
drivers/net/phy/marvell.c +19 -12
@@ -1751,15 +1751,12 @@ static int marvell_vct5_wait_complete(struct phy_device *phydev)int val;for (i =0 ; i <32 ; i++) { - val =phy_read_paged (phydev,MII_MARVELL_VCT5_PAGE , -MII_VCT5_CTRL ); + val =__phy_read (phydev,MII_VCT5_CTRL );if (val <0 )return val;if (val &MII_VCT5_CTRL_COMPLETE )return 0 ; - -usleep_range (1000 ,2000 ); }phydev_err (phydev,"Timeout while waiting for cable test to finish\n" );
@@ -1773,7 +1770,7 @@ static int marvell_vct5_amplitude(struct phy_device *phydev, int pair)int reg; reg =MII_VCT5_TX_RX_MDI0_COUPLING + pair; - val =phy_read_paged (phydev,MII_MARVELL_VCT5_PAGE , reg); + val =__phy_read (phydev, reg);if (val <0 )return 0 ;
@@ -1805,9 +1802,8 @@ static int marvell_vct5_amplitude_distance(struct phy_device *phydev,int mV;int i; - err =phy_write_paged (phydev,MII_MARVELL_VCT5_PAGE , -MII_VCT5_SAMPLE_POINT_DISTANCE , - distance); + err =__phy_write (phydev,MII_VCT5_SAMPLE_POINT_DISTANCE , + distance);if (err)return err;
@@ -1816,8 +1812,7 @@ static int marvell_vct5_amplitude_distance(struct phy_device *phydev,MII_VCT5_CTRL_SAMPLES_DEFAULT |MII_VCT5_CTRL_SAMPLE_POINT |MII_VCT5_CTRL_PEEK_HYST_DEFAULT ; - err =phy_write_paged (phydev,MII_MARVELL_VCT5_PAGE , -MII_VCT5_CTRL , reg); + err =__phy_write (phydev,MII_VCT5_CTRL , reg);if (err)return err;
@@ -1840,6 +1835,7 @@ static int marvell_vct5_amplitude_graph(struct phy_device *phydev) {struct marvell_priv *priv = phydev->priv;int distance; +int page;int err;u16 reg;
@@ -1853,16 +1849,27 @@ static int marvell_vct5_amplitude_graph(struct phy_device *phydev)if (err)return err; +/* Reading the TDR data is very MDIO heavy. We need to optimize +* access to keep the time to a minimum. So lock the bus once, +* and don't release it until complete. We can then avoid having +* to change the page for every access, greatly speeding things +* up. +*/ + page =phy_select_page (phydev,MII_MARVELL_VCT5_PAGE ); +if (page <0 ) +return page; +for (distance = priv->first; distance <= priv->last; distance += priv->step) { err =marvell_vct5_amplitude_distance (phydev, distance, priv->pair);if (err) -return err; + goto restore_page; } -return 0 ; +restore_page: +return phy_restore_page (phydev, page, err); }static int marvell_cable_test_start_common (struct phy_device *phydev)
Signature · 1 line
2.27.0.rc0
Andrew Lunn
maintainerPATCH v3 7/7 net: phy: marvell: Configure TDR pulse based on measurement length
In reply to Andrew LunnWhen performing a TDR measurement for a short distance, the pulse width should be low, to help differentiate between the outgoing pulse and any reflection. For longer distances, the pulse should be wider, to help with attenuation.
--- drivers/net/phy/marvell.c | 25 +++++++++++++++++++++++-- 1 file changed, 23 insertions(+), 2 deletions(-)
drivers/net/phy/marvell.c +23 -2
@@ -214,6 +214,11 @@#define MII_VCT5_TX_PULSE_CTRL_MAX_AMP BIT(7)#define MII_VCT5_TX_PULSE_CTRL_GT_140m_46_86mV (0x6 << 0) +/* For TDR measurements less than 11 meters, a short pulse should be +* used. +*/ +#define TDR_SHORT_CABLE_LENGTH 11 +#define MII_VCT7_PAIR_0_DISTANCE 0x10#define MII_VCT7_PAIR_1_DISTANCE 0x11#define MII_VCT7_PAIR_2_DISTANCE 0x12
@@ -1835,14 +1840,19 @@ static int marvell_vct5_amplitude_graph(struct phy_device *phydev) {struct marvell_priv *priv = phydev->priv;int distance; +u16 width;int page;int err;u16 reg; +if (priv->first <=TDR_SHORT_CABLE_LENGTH ) + width = MII_VCT5_TX_PULSE_CTRL_PULSE_WIDTH_32nS; +else + width = MII_VCT5_TX_PULSE_CTRL_PULSE_WIDTH_128nS; + reg = MII_VCT5_TX_PULSE_CTRL_GT_140m_46_86mV |MII_VCT5_TX_PULSE_CTRL_DONT_WAIT_LINK_DOWN | -MII_VCT5_TX_PULSE_CTRL_MAX_AMP | - MII_VCT5_TX_PULSE_CTRL_PULSE_WIDTH_32nS; +MII_VCT5_TX_PULSE_CTRL_MAX_AMP | width; err =phy_write_paged (phydev,MII_MARVELL_VCT5_PAGE ,MII_VCT5_TX_PULSE_CTRL , reg);
@@ -1866,6 +1876,17 @@ static int marvell_vct5_amplitude_graph(struct phy_device *phydev) priv->pair);if (err) goto restore_page; + +if (distance >TDR_SHORT_CABLE_LENGTH && + width == MII_VCT5_TX_PULSE_CTRL_PULSE_WIDTH_32nS) { + width = MII_VCT5_TX_PULSE_CTRL_PULSE_WIDTH_128nS; + reg = MII_VCT5_TX_PULSE_CTRL_GT_140m_46_86mV | +MII_VCT5_TX_PULSE_CTRL_DONT_WAIT_LINK_DOWN | +MII_VCT5_TX_PULSE_CTRL_MAX_AMP | width; + err =__phy_write (phydev,MII_VCT5_TX_PULSE_CTRL , reg); +if (err) + goto restore_page; + } } restore_page:
Signature · 1 line
2.27.0.rc0
David Miller
maintainerFrom: Andrew Lunn <[email protected]>
Date: Wed, 27 May 2020 00:21:36 +0200
Quoted 8 lines
Some ethernet PHYs allow access to raw TDR data in addition to summary diagnostics information. Add support for retrieving this data via netlink ethtool. The basic structure in the core is the same as for normal phy diagnostics, the PHY driver simply uses different helpers to fill the netlink message with different data.
There is a graphical tool under development, as well a ethtool(1) which can dump the data as text and JSON.
...
Series applied, thanks Andrew.