python/machine.py: refactor shutdown
v4 cover python/machine.py: refactor shutdown
v4:
001/3:[----] [--] 'python/machine.py: consolidate _post_shutdown()' 002/3:[0010] [FC] 'python/machine.py: refactor shutdown' 003/3:[----] [--] 'python/machine.py: re-add sigkill warning suppression'
- Rebased
- Fixed exception handler to actually handle exception :(
v3:
- Split _post_shutdown refactor into own patch (now 1/3)
- Re-add sigkill warning squelch (now 3/3)
Applies straight to origin/master, ought to pass pylint and flake8:
Quoted 3 lines
cd ~/src/qemu/python/qemu
pylint *.py
flake8 *.py
John Snow (3):
python/machine.py: consolidate _post_shutdown() python/machine.py: refactor shutdown python/machine.py: re-add sigkill warning suppression
python/qemu/machine.py | 108 ++++++++++++++++++++++++++++++----------- 1 file changed, 79 insertions(+), 29 deletions(-)
Signature · 1 line
2.21.3
PATCH v4 1/3 python/machine.py: consolidate _post_shutdown()
Move more cleanup actions into _post_shutdown. As a change, if QEMU should so happen to be terminated during a call to wait(), that event will now be logged.
This is not likely to occur during normative use.
--- python/qemu/machine.py | 27 +++++++++++++-------------- 1 file changed, 13 insertions(+), 14 deletions(-)
python/qemu/machine.py +13 -14
@@ -283,6 +283,8 @@ def _post_launch(self): self._qmp.accept() def _post_shutdown(self): + self._load_io_log() + if self._qemu_log_file is not None: self._qemu_log_file.close() self._qemu_log_file = None
@@ -296,6 +298,17 @@ def _post_shutdown(self): while len(self._remove_files) > 0: self._remove_if_exists(self._remove_files.pop()) + exitcode = self.exitcode() + if exitcode is not None and exitcode < 0: + msg = 'qemu received signal %i; command: "%s"' + if self._qemu_full_args: + command = ' '.join(self._qemu_full_args) + else: + command = '' + LOG.warning(msg, -int(exitcode), command) + + self._launched = False + def launch(self): """ Launch the VM and make sure we cleanup and expose the
@@ -344,7 +357,6 @@ def wait(self): self._popen.wait() if self._qmp: self._qmp.close() - self._load_io_log() self._post_shutdown() def shutdown(self, has_quit=False, hard=False):
@@ -371,21 +383,8 @@ def shutdown(self, has_quit=False, hard=False): self._popen.kill() self._popen.wait() - self._load_io_log() self._post_shutdown() - exitcode = self.exitcode() - if exitcode is not None and exitcode < 0 and \ - not (exitcode == -9 and hard): - msg = 'qemu received signal %i: %s' - if self._qemu_full_args: - command = ' '.join(self._qemu_full_args) - else: - command = '' - LOG.warning(msg, -int(exitcode), command) - - self._launched = False - def kill(self): self.shutdown(hard=True)
Signature · 1 line
2.21.3
PATCH v4 2/3 python/machine.py: refactor shutdown
In reply to John SnowThis is done primarily to avoid the 'bare except' pattern, which suppresses ALL exceptions and not just ones that we are anticipating to see.
Replace this with a pattern that isolates the different kind of shutdown paradigms and a new fallback shutdown handler that gracefully attempts one before the other.
Ensure that the main shutdown() function ALWAYS calls the post_shutdown logic, no matter what kind of error we encountered. Subprocess wait timeouts are considered expected, everything else is unexpected.
In cases where we encounter an expected error in the graceful shutdown timeout, we will not re-raise an exception above shutdown(). Otherwise, after post_shutdown cleanup, we will.
I anticipate that this WILL lead to additional bug reports filed against this module, but that is unfortunately somewhat the point: This code shouldn't be hiding failures that exist elsewhere within the python code.
--- python/qemu/machine.py | 76 +++++++++++++++++++++++++++++++++--------- 1 file changed, 61 insertions(+), 15 deletions(-)
python/qemu/machine.py +61 -15
@@ -359,9 +359,59 @@ def wait(self): self._qmp.close() self._post_shutdown() - def shutdown(self, has_quit=False, hard=False): + def _hard_shutdown(self) -> None: """ - Terminate the VM and clean up + Kill the VM if it is running. + """ + if not self.is_running(): + return + + self._popen.kill() + self._popen.wait(timeout=60) + + def _soft_shutdown(self, has_quit: bool = False, timeout: int = 3) -> None: + """ + Attempt to shutdown the VM gracefully if it is running. + + :param has_quit: When True, don't attempt to issue 'quit' QMP command + :param timeout: Timeout for graceful shutdown. Default 3 seconds. + """ + if not self.is_running(): + return + + if self._qmp is not None: + if not has_quit: + try: + self._qmp.cmd('quit') + except ConnectionResetError: + # QMP went away just before or just after sending 'quit'. + # Covers EPIPE, ECONNABORTED, ECONNREFUSED, and ECONNRESET. + if self.is_running(): + # Process is running, but the control channel is lost. + # No remaining way to shut it down 'gracefully'. + raise + self._qmp.close() + + self._popen.wait(timeout=timeout) + + def _do_shutdown(self, has_quit: bool = False, timeout: int = 3) -> None: + """ + Attempt to shutdown the VM gracefully; fallback to a hard shutdown. + + :param has_quit: When True, don't attempt to issue 'quit' QMP command + :param timeout: Timeout for graceful shutdown. Default 3 seconds. + """ + try: + self._soft_shutdown(has_quit, timeout) + except subprocess.TimeoutExpired: + self._hard_shutdown() + except: + self._hard_shutdown() + raise + + def shutdown(self, has_quit: bool = False, hard: bool = False) -> None: + """ + Terminate the VM (gracefully if possible) and perform cleanup. """ # If we keep the console socket open, we may deadlock waiting # for QEMU to exit, while QEMU is waiting for the socket to
@@ -370,22 +420,18 @@ def shutdown(self, has_quit=False, hard=False): self._console_socket.close() self._console_socket = None - if self.is_running(): + try: if hard: - self._popen.kill() - elif self._qmp: - try: - if not has_quit: - self._qmp.cmd('quit') - self._qmp.close() - self._popen.wait(timeout=3) - except: - self._popen.kill() - self._popen.wait() - - self._post_shutdown() + self._hard_shutdown() + else: + self._do_shutdown(has_quit) + finally: + self._post_shutdown() def kill(self): + """ + Terminate the VM forcefully and perform cleanup. + """ self.shutdown(hard=True) def set_qmp_monitor(self, enabled=True):
Signature · 1 line
2.21.3
PATCH v4 3/3 python/machine.py: re-add sigkill warning suppression
In reply to John SnowIf the user kills QEMU on purpose, we don't need to warn them about that having happened: they know already.
--- python/qemu/machine.py | 9 +++++++-- 1 file changed, 7 insertions(+), 2 deletions(-)
python/qemu/machine.py +7 -2
@@ -22,6 +22,7 @@ import os import subprocess import shutil +import signal import socket import tempfile from typing import Optional, Type
@@ -122,6 +123,7 @@ def __init__(self, binary, args=None, wrapper=None, name=None, self._console_address = None self._console_socket = None self._remove_files = [] + self._killed = False def __enter__(self): return self
@@ -282,7 +284,7 @@ def _post_launch(self): if self._qmp: self._qmp.accept() - def _post_shutdown(self): + def _post_shutdown(self) -> None: self._load_io_log() if self._qemu_log_file is not None:
@@ -299,7 +301,8 @@ def _post_shutdown(self): self._remove_if_exists(self._remove_files.pop()) exitcode = self.exitcode() - if exitcode is not None and exitcode < 0: + if (exitcode is not None and exitcode < 0 + and not (self._killed and exitcode == -signal.SIGKILL)): msg = 'qemu received signal %i; command: "%s"' if self._qemu_full_args: command = ' '.join(self._qemu_full_args)
@@ -307,6 +310,7 @@ def _post_shutdown(self): command = '' LOG.warning(msg, -int(exitcode), command) + self._killed = False self._launched = False def launch(self):
@@ -422,6 +426,7 @@ def shutdown(self, has_quit: bool = False, hard: bool = False) -> None: try: if hard: + self._killed = True self._hard_shutdown() else: self._do_shutdown(has_quit)
Signature · 1 line
2.21.3