arm: dts: imx7: Fix error in coresight TPIU graph connection
Subsystems (2)
PATCH 1/1 arm: dts: imx7: Fix error in coresight TPIU graph connection
OF graph endpoint connections must be bidirectional and dtc warn if they are not. i.MX7 based DTs have an error and generate warnings:
arch/arm/dts/imx7d-sdb.dtb: Warning (graph_endpoint):
/replicator/ports/port at 0/endpoint: graph connection to node '/soc/tpiu at 30087000/port/endpoint' is not bidirectional arch/arm/dts/imx7d-sdb.dtb: Warning (graph_endpoint):
/soc/tpiu at 30087000/port/endpoint: graph connection to node '/replicator/ports/port at 1/endpoint' is not bidirectional
--- arch/arm/dts/imx7s.dtsi | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
arch/arm/dts/imx7s.dtsi +1 -1
@@ -323,7 +323,7 @@ port { tpiu_in_port: endpoint { slave-mode; - remote-endpoint = <&replicator_out_port1>; + remote-endpoint = <&replicator_out_port0>; }; }; };
Signature · 1 line
2.25.1
PATCH 1/1 arm: dts: imx7: Fix error in coresight TPIU graph connection
Quoted 10 lines
OF graph endpoint connections must be bidirectional and dtc warn if they are not. i.MX7 based DTs have an error and generate warnings:
arch/arm/dts/imx7d-sdb.dtb: Warning (graph_endpoint):
/replicator/ports/port at 0/endpoint: graph connection to node '/soc/tpiu at 30087000/port/endpoint' is not bidirectionalarch/arm/dts/imx7d-sdb.dtb: Warning (graph_endpoint):
/soc/tpiu at 30087000/port/endpoint: graph connection to node '/replicator/ports/port at 1/endpoint' is not bidirectionalSigned-off-by Ilko Iliev <[email protected]>
Applied to u-boot-imx, master, thanks !
Best regards,
Stefano Babic
Signature · 5 lines
===================================================================== DENX Software Engineering GmbH, Managing Director: Wolfgang Denk HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: sbabic at denx.de =====================================================================