mfd: rn5t618: Fix caching of battery related registers
PATCH 1/1 mfd: rn5t618: Fix caching of battery related registers
Battery status changes dynamically, so the corresponding registers need to be considered volatile. Affected registers are:
- fuel gauge
- battery status
- battery interrupt
Signed-off-by Andreas Kemnade <[email protected]>
--- drivers/mfd/rn5t618.c | 3 +++ 1 file changed, 3 insertions(+)
drivers/mfd/rn5t618.c +3 -0
@@ -44,6 +44,9 @@ static bool rn5t618_volatile_reg(struct device *dev, unsigned int reg)case RN5T618_INTMON : case RN5T618_RTC_CTRL1 ... RN5T618_RTC_CTRL2: case RN5T618_RTC_SECONDS ... RN5T618_RTC_YEAR: +case RN5T618_CHGSTATE : + case RN5T618_CHGCTRL_IRR ... RN5T618_CHGERR_MONI: + case RN5T618_CONTROL ... RN5T618_CC_AVEREG0:return true;default :return false;
Signature · 1 line
2.20.1
Lee Jones
AppliedQuoted 10 lines · Andreas Kemnade
Battery status changes dynamically, so the corresponding registers need to be considered volatile. Affected registers are:
- fuel gauge
- battery status
- battery interruptSigned-off-by Andreas Kemnade <[email protected]>--- drivers/mfd/rn5t618.c | 3 +++ 1 file changed, 3 insertions(+)
Applied, thanks.
Signature · 4 lines
Lee Jones [李琼斯] Senior Technical Lead - Developer Services Linaro.org │ Open source software for Arm SoCs Follow Linaro: Facebook | Twitter | Blog