dt-bindings: watchdog: sp-805: Convert to Json-schema

PATCH Applied Andre Przywara 3 participants 3 messages Sep 9, 2020 – Sep 15, 2020

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH v2 1/1 dt-bindings: watchdog: sp-805: Convert to Json-schema

Convert the ARM SP-805 watchdog IP DT binding over to Json-schema.

A straight-forward conversion, but the requirement for providing two clocks got strengthened from "should" to "must".

---
Hi,

this is just the bindings conversion patch, updated to address Rob's comments:
- Remove redundant primecell.yaml inclusion
- Reference watchdog.yaml
- Drop now redundant timeout-sec property
- Add unevaluatedProperties

The DT fixes are independent and now partly already queued, so I am posting this separately.

Cheers,
Andre

 .../bindings/watchdog/arm,sp805.txt           | 32 ---------
 .../bindings/watchdog/arm,sp805.yaml          | 71 +++++++++++++++++++
 2 files changed, 71 insertions(+), 32 deletions(-)
 delete mode 100644 Documentation/devicetree/bindings/watchdog/arm,sp805.txt
 create mode 100644 Documentation/devicetree/bindings/watchdog/arm,sp805.yaml
Documentation/devicetree/bindings/watchdog/arm,sp805.txt deleted +0 -32
deleted file mode 100644
index bee6f1f0e41b..000000000000
@@ -1,32 +0,0 @@
-ARM AMBA Primecell SP805 Watchdog
-
-SP805 WDT is a ARM Primecell Peripheral and has a standard-id register that
-can be used to identify the peripheral type, vendor, and revision.
-This value can be used for driver matching.
-
-As SP805 WDT is a primecell IP, it follows the base bindings specified in
-'arm/primecell.txt'
-
-Required properties:
-- compatible:  Should be "arm,sp805" & "arm,primecell"
-- reg:         Should contain location and length for watchdog timer register
-- clocks:      Clocks driving the watchdog timer hardware. This list should be
-               2 clocks. With 2 clocks, the order is wdog_clk, apb_pclk
-               wdog_clk can be equal to or be a sub-multiple of the apb_pclk
-               frequency
-- clock-names: Shall be "wdog_clk" for first clock and "apb_pclk" for the
-               second one
-
-Optional properties:
-- interrupts:  Should specify WDT interrupt number
-- timeout-sec: Should specify default WDT timeout in seconds. If unset, the
-               default timeout is determined by the driver
-
-Example:
-	watchdog@66090000 {
-		compatible = "arm,sp805", "arm,primecell";
-		reg = <0x66090000 0x1000>;
-		interrupts = <GIC_SPI 406 IRQ_TYPE_LEVEL_HIGH>;
-		clocks = <&wdt_clk>, <&apb_pclk>;
-		clock-names = "wdog_clk", "apb_pclk";
-	};
Documentation/devicetree/bindings/watchdog/arm,sp805.yaml new file +71 -0

71 lines not on this page · raw message

Signature · 1 line
2.17.1
Acked-by on v2 1/1
#1 lore raw
Quoted 133 lines · Andre Przywara

Convert the ARM SP-805 watchdog IP DT binding over to Json-schema.

A straight-forward conversion, but the requirement for providing two clocks got strengthened from "should" to "must".

---
Hi,

this is just the bindings conversion patch, updated to address Rob's comments:
- Remove redundant primecell.yaml inclusion
- Reference watchdog.yaml
- Drop now redundant timeout-sec property
- Add unevaluatedProperties

The DT fixes are independent and now partly already queued, so I am posting this separately.

Cheers,
Andre

 .../bindings/watchdog/arm,sp805.txt           | 32 ---------
 .../bindings/watchdog/arm,sp805.yaml          | 71 +++++++++++++++++++
 2 files changed, 71 insertions(+), 32 deletions(-)
 delete mode 100644 Documentation/devicetree/bindings/watchdog/arm,sp805.txt
 create mode 100644 Documentation/devicetree/bindings/watchdog/arm,sp805.yaml
Documentation/devicetree/bindings/watchdog/arm,sp805.txt deleted +0 -32
deleted file mode 100644
index bee6f1f0e41b..000000000000
@@ -1,32 +0,0 @@
-ARM AMBA Primecell SP805 Watchdog
-
-SP805 WDT is a ARM Primecell Peripheral and has a standard-id register that
-can be used to identify the peripheral type, vendor, and revision.
-This value can be used for driver matching.
-
-As SP805 WDT is a primecell IP, it follows the base bindings specified in
-'arm/primecell.txt'
-
-Required properties:
-- compatible:  Should be "arm,sp805" & "arm,primecell"
-- reg:         Should contain location and length for watchdog timer register
-- clocks:      Clocks driving the watchdog timer hardware. This list should be
-               2 clocks. With 2 clocks, the order is wdog_clk, apb_pclk
-               wdog_clk can be equal to or be a sub-multiple of the apb_pclk
-               frequency
-- clock-names: Shall be "wdog_clk" for first clock and "apb_pclk" for the
-               second one
-
-Optional properties:
-- interrupts:  Should specify WDT interrupt number
-- timeout-sec: Should specify default WDT timeout in seconds. If unset, the
-               default timeout is determined by the driver
-
-Example:
-	watchdog@66090000 {
-		compatible = "arm,sp805", "arm,primecell";
-		reg = <0x66090000 0x1000>;
-		interrupts = <GIC_SPI 406 IRQ_TYPE_LEVEL_HIGH>;
-		clocks = <&wdt_clk>, <&apb_pclk>;
-		clock-names = "wdog_clk", "apb_pclk";
-	};
Documentation/devicetree/bindings/watchdog/arm,sp805.yaml new file +61 -0
new file mode 100644
index 000000000000..a69cac8ec208
@@ -0,0 +1,71 @@
+# SPDX-License-Identifier: GPL-2.0
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/watchdog/arm,sp805.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: ARM AMBA Primecell SP805 Watchdog
+
+maintainers:
+  - Viresh Kumar <[email protected]>
+
+description: |+
+  The Arm SP805 IP implements a watchdog device, which triggers an interrupt
+  after a configurable time period. If that interrupt has not been serviced
+  when the next interrupt would be triggered, the reset signal is asserted.
+
+allOf:
+  - $ref: /schemas/watchdog/watchdog.yaml#
+
+# Need a custom select here or 'arm,primecell' will match on lots of nodes
+select:
+  properties:
+    compatible:
+      contains:
+        const: arm,sp805
+  required:
+    - compatible
+
+properties:
+  compatible:
+    items:
+      - const: arm,sp805
+      - const: arm,primecell
+
+  interrupts:
+    maxItems: 1
+
+  reg:
+    maxItems: 1
+
+  clocks:
+    description: |
+      Clocks driving the watchdog timer hardware. The first clock is used
+      for the actual watchdog counter. The second clock drives the register
+      interface.
+    minItems: 2
+    maxItems: 2
+
+  clock-names:
+    items:
+      - const: wdog_clk
+      - const: apb_pclk
+
+required:
+  - compatible
+  - reg
+  - clocks
+  - clock-names
+
+unevaluatedProperties: false
+

Documentation/devicetree/bindings/watchdog/arm,sp805.yaml line 71

Quoted 10 lines
Documentation/devicetree/bindings/watchdog/arm,sp805.yaml new file +10 -0
+examples:
+  - |
+    #include <dt-bindings/interrupt-controller/arm-gic.h>
+    watchdog@66090000 {
+        compatible = "arm,sp805", "arm,primecell";
+        reg = <0x66090000 0x1000>;
+        interrupts = <GIC_SPI 406 IRQ_TYPE_LEVEL_HIGH>;
+        clocks = <&wdt_clk>, <&apb_pclk>;
+        clock-names = "wdog_clk", "apb_pclk";
+    };
Signature · 1 line
viresh
maintainer Applied
#2 lore raw
In reply to Andre Przywara
Quoted 19 lines · Andre Przywara

Convert the ARM SP-805 watchdog IP DT binding over to Json-schema.

A straight-forward conversion, but the requirement for providing two clocks got strengthened from "should" to "must".

---
Hi,

this is just the bindings conversion patch, updated to address Rob's comments:
- Remove redundant primecell.yaml inclusion
- Reference watchdog.yaml
- Drop now redundant timeout-sec property
- Add unevaluatedProperties

The DT fixes are independent and now partly already queued, so I am posting this separately.

Quoted 9 lines

Cheers,
Andre

 .../bindings/watchdog/arm,sp805.txt           | 32 ---------
 .../bindings/watchdog/arm,sp805.yaml          | 71 +++++++++++++++++++
 2 files changed, 71 insertions(+), 32 deletions(-)
 delete mode 100644 Documentation/devicetree/bindings/watchdog/arm,sp805.txt
 create mode 100644 Documentation/devicetree/bindings/watchdog/arm,sp805.yaml

Applied, thanks!