mac80211: extend AQL aggregation estimation to HE and fix unit mismatch
PATCH 1/2 mac80211: extend AQL aggregation estimation to HE and fix unit mismatch
The unit of the return value of ieee80211_get_rate_duration is nanoseconds, not milliseconds. Adjust the duration checks to account for that.
For higher data rates, allow larger estimated aggregation sizes, and add some values for HE as well, which can use much larger aggregates.
Since small packets with high data rates can now lead to duration values too small for info->tx_time_est, return a minimum of 4us.
--- net/mac80211/airtime.c | 16 +++++++++++----- 1 file changed, 11 insertions(+), 5 deletions(-)
net/mac80211/airtime.c +11 -5
@@ -668,20 +668,26 @@ u32 ieee80211_calc_expected_tx_airtime(struct ieee80211_hw *hw,* This will not be very accurate, but much better than simply * assuming un-aggregated tx in all cases. */ -if (duration >400 )/* <= VHT20 MCS2 1S */ +if (duration >400 *1024 )/* <= VHT20 MCS2 1S */ agg_shift =1 ; -else if (duration >250 )/* <= VHT20 MCS3 1S or MCS1 2S */ +else if (duration >250 *1024 )/* <= VHT20 MCS3 1S or MCS1 2S */ agg_shift =2 ; -else if (duration >150 )/* <= VHT20 MCS5 1S or MCS3 2S */ +else if (duration >150 *1024 )/* <= VHT20 MCS5 1S or MCS2 2S */ agg_shift =3 ; -else +else if (duration >70 *1024 )/* <= VHT20 MCS5 2S */ agg_shift =4 ; +else if (stat.encoding !=RX_ENC_HE || + duration >20 *1024 )/* <= HE40 MCS6 2S */ + agg_shift =5 ; +else + agg_shift =6 ; duration *= len; duration /=AVG_PKT_SIZE ; duration /=1024 ; + duration += (overhead >> agg_shift); -return duration + (overhead >> agg_shift); +return max_t (u32, duration,4 ); }if (!conf)
Signature · 1 line
2.28.0
PATCH 2/2 mac80211: add AQL support for VHT160 tx rates
When converting from struct ieee80211_tx_rate to ieee80211_rx_status, there was one check missing to fill in the bandwidth for 160 MHz
--- net/mac80211/airtime.c | 4 +++- 1 file changed, 3 insertions(+), 1 deletion(-)
net/mac80211/airtime.c +3 -1
@@ -560,7 +560,9 @@ static int ieee80211_fill_rx_status(struct ieee80211_rx_status *stat,if (rate->idx <0 || !rate->count)return -1 ; -if (rate->flags &IEEE80211_TX_RC_80_MHZ_WIDTH ) +if (rate->flags &IEEE80211_TX_RC_160_MHZ_WIDTH ) + stat->bw =RATE_INFO_BW_160 ; +else if (rate->flags &IEEE80211_TX_RC_80_MHZ_WIDTH ) stat->bw =RATE_INFO_BW_80 ;else if (rate->flags &IEEE80211_TX_RC_40_MHZ_WIDTH ) stat->bw =RATE_INFO_BW_40 ;
Signature · 1 line
2.28.0
Quoted 2 lines · Felix Fietkau
The unit of the return value of
ieee80211_get_rate_durationis nanoseconds, not milliseconds.
s/milli/micro/ here, no?
Quoted 5 lines
Adjust the duration checks to account for that.
For higher data rates, allow larger estimated aggregation sizes, and add some values for HE as well, which can use much larger aggregates. Since small packets with high data rates can now lead to duration values too small forinfo->tx_time_est, return a minimum of 4us.
-Toke
Quoted 6 lines · Toke Høiland-Jørgensen
Quoted 2 lines · Felix Fietkau
The unit of the return value of
ieee80211_get_rate_durationis nanoseconds, not milliseconds.s/milli/micro/ here, no?
Right.
Quoted 7 lines
Quoted 5 lines
Adjust the duration checks to account for that.
For higher data rates, allow larger estimated aggregation sizes, and add some values for HE as well, which can use much larger aggregates. Since small packets with high data rates can now lead to duration values too small forinfo->tx_time_est, return a minimum of 4us.Fixes tag?
Will add it and send v2.
Thanks,
- Felix