Skip to contentSkip to conversation

Fix/Improve sync clock mode handling

PATCH Superseded Nuno Sá 3 participants 17 messages Jan 21, 2021 – Feb 9, 2021

Subsystems (5)

v1 of 2 Superseded Latest is v2 →

lore
Share & tools
lore

Nuno Sá

author maintainer
#0 lore raw

cover Fix/Improve sync clock mode handling

The first patch in this series is just a simple helper to lock/unlock the device. Having these helpers make the code slightly neater (IMHO).

The following patches introduces changes in the sampling frequency calculation when sync scale/pps modes are used. First, it's important to understand the purpose of this mode and how it should be used. Let's say our part has an internal rate of 4250 (e.g adis1649x family) and the user wants an output rate of 200SPS. Obviously, we can't use this sampling rate and divide back down to get 200 SPS with decimation on. Hence, we can use this mode to give an input clock of 1HZ, scale it to something like 4200 or 4000 SPS and then use the decimation filter to get the exact desired 200SPS. There are also some limits that should be taken into account when scaling:

* For the devices in the adis16475 driver:
- Input sync frequency range is 1 to 128 Hz
- Native sample rate: 2 kSPS. Optimal range: 1900-2100 sps

* For the adis1649x family (adis16480 driver):
- Input sync frequency range is 1 to 128 Hz
- Native sample rate: 4.25 kSPS. Optimal range: 4000-4250 sps

I'm not 100% convinced on how to handle the optimal minimum. For now, I'm just throwing a warning saying we might get into trouble if we get a value lower than that. I was also tempted to just return -EINVAL or clamp the value. However, I know that there are ADI customers that (for some reason) are using a sampling rate lower than the minimum advised.

That said, the patch for the adis16480 driver is a fix as this mode was being wrongly handled. There should not be a "separation" between using the sync_scale and the dec_rate registers. The way things were being done, we could easily get into a situation where the part could be running with an internal rate way lower than the optimal minimum.

For the adis16475 drivers, things were not really wrong. They were just not optimal as we were forcing users to specify the IMU scaled internal rate once in the devicetree. Calculating things at runtime gives much more flexibility to choose the output rate.

Nuno Sá (4):
iio: adis: add helpers for locking
iio: adis16480: fix pps mode sampling frequency math
iio: adis16475: improve sync scale mode handling
dt-bindings: adis16475: remove property

 .../bindings/iio/imu/adi,adis16475.yaml       |   9 --
 drivers/iio/imu/adis16475.c                   | 110 ++++++++++++----
 drivers/iio/imu/adis16480.c                   | 120 +++++++++++++-----
 include/linux/iio/imu/adis.h                  |  10 ++
 4 files changed, 178 insertions(+), 71 deletions(-)
Signature · 1 line
2.30.0
author maintainer
#1 lore raw

PATCH 1/4 iio: adis: add helpers for locking

Add some helpers to lock and unlock the device.

---
 include/linux/iio/imu/adis.h | 10 ++++++++++
 1 file changed, 10 insertions(+)
include/linux/iio/imu/adis.h +10 -0
index 04e96d688ba9..f9b728d490b1 100644
@@ -428,6 +428,16 @@ static inline int adis_initial_startup(struct adis *adis)
 	return ret;
 }
 
+static inline void adis_dev_lock(struct adis *adis)
+{
+	mutex_lock(&adis->state_lock);
+}
+
+static inline void adis_dev_unlock(struct adis *adis)
+{
+	mutex_unlock(&adis->state_lock);
+}
+
 int adis_single_conversion(struct iio_dev *indio_dev,
 	const struct iio_chan_spec *chan, unsigned int error_mask,
 	int *val);
Signature · 1 line
2.30.0
maintainer
#2 lore raw

Re: [PATCH 1/4] iio: adis: add helpers for locking

Quoted 3 lines · On Thu, 21 Jan 2021 12:49:51 +0100 Nuno Sá <[email protected]> wrote:

Add some helpers to lock and unlock the device.

Hi Nuno

For a patch like this I'd also expect to see it immediately used in all relevant places in the driver. I don't want a mixture going forwards of this vs direct access to the lock.

No need to separate that into two patches for such a simple case just introduce this and put it to use. There aren't that many call sites anyway from a quick grep.

Thanks,

Jonathan

Quoted 25 lines
---
 include/linux/iio/imu/adis.h | 10 ++++++++++
 1 file changed, 10 insertions(+)
include/linux/iio/imu/adis.h +10 -0
index 04e96d688ba9..f9b728d490b1 100644
@@ -428,6 +428,16 @@ static inline int adis_initial_startup(struct adis *adis)
 	return ret;
 }
 
+static inline void adis_dev_lock(struct adis *adis)
+{
+	mutex_lock(&adis->state_lock);
+}
+
+static inline void adis_dev_unlock(struct adis *adis)
+{
+	mutex_unlock(&adis->state_lock);
+}
+
 int adis_single_conversion(struct iio_dev *indio_dev,
 	const struct iio_chan_spec *chan, unsigned int error_mask,
 	int *val);
author maintainer
#3 lore raw

RE: [PATCH 1/4] iio: adis: add helpers for locking

Quoted 11 lines

From: Jonathan Cameron <[email protected]>
Sent: Sunday, January 24, 2021 2:30 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Rob Herring <[email protected]>; Peter Meerwald-Stadler <[email protected]>; Lars-Peter Clausen <[email protected]>; Hennerich, Michael <[email protected]>; Ardelean, Alexandru <[email protected]>
Subject: Re: [PATCH 1/4] iio: adis: add helpers for locking

Quoted 9 lines
Quoted 3 lines · On Thu, 21 Jan 2021 12:49:51 +0100 Nuno Sá <[email protected]> wrote:

Add some helpers to lock and unlock the device.

Hi Nuno

Hi Jonathan,

Quoted 3 lines

For a patch like this I'd also expect to see it immediately used in all relevant places in the driver. I don't want a mixture going forwards of this vs direct access to the lock.

Fully agreed...

Quoted 4 lines

No need to separate that into two patches for such a simple case just introduce this and put it to use. There aren't that many call sites anyway from a quick grep.

Ok, will do that in v2.

- Nuno Sá

author maintainer
#4 lore raw

PATCH 2/4 iio: adis16480: fix pps mode sampling frequency math

In reply to Nuno Sá

When using PPS mode, the input clock needs to be scaled so that we have an IMU sample rate between (optimally) 4000 and 4250. After this, we can use the decimation filter to lower the sampling rate in order to get what the user wants. Optimally, the user sample rate is a multiple of both the IMU sample rate and the input clock. Hence, calculating the sync_scale dynamically gives us better chances of achieving a perfect/integer value for DEC_RATE. The math here is:
1. lcm of the input clock and the desired output rate.
2. get the highest multiple of the previous result lower than the adis max rate.
3. The last result becomes the IMU sample rate. Use that to calculate SYNC_SCALE and DEC_RATE (to get the user output rate).

Fixes 326e2357553d3 ("iio: imu: adis16480: Add support for external clock")
---
 drivers/iio/imu/adis16480.c | 120 ++++++++++++++++++++++++++----------
 1 file changed, 86 insertions(+), 34 deletions(-)
drivers/iio/imu/adis16480.c +86 -34
index dfe86c589325..7620822f3350 100644
@@ -17,6 +17,7 @@
 #include <linux/slab.h>
 #include <linux/sysfs.h>
 #include <linux/module.h>
+#include <linux/lcm.h>
 
 #include <linux/iio/iio.h>
 #include <linux/iio/sysfs.h>
@@ -312,7 +313,8 @@ static int adis16480_debugfs_init(struct iio_dev *indio_dev)
 static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int val2)
 {
 	struct adis16480 *st = iio_priv(indio_dev);
-	unsigned int t, reg;
+	unsigned int t, sample_rate = st->clk_freq;
+	int ret;
 
 	if (val < 0 || val2 < 0)
 		return -EINVAL;
@@ -321,28 +323,63 @@ static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int val2)
 	if (t == 0)
 		return -EINVAL;
 
+	adis_dev_lock(&st->adis);
 	/*
-	 * When using PPS mode, the rate of data collection is equal to the
-	 * product of the external clock frequency and the scale factor in the
-	 * SYNC_SCALE register.
-	 * When using sync mode, or internal clock, the output data rate is
-	 * equal with  the clock frequency divided by DEC_RATE + 1.
+	 * When using PPS mode, the input clock needs to be scaled so that we have an IMU
+	 * sample rate between (optimally) 4000 and 4250. After this, we can use the
+	 * decimation filter to lower the sampling rate in order to get what the user wants.
+	 * Optimally, the user sample rate is a multiple of both the IMU sample rate and
+	 * the input clock. Hence, calculating the sync_scale dynamically gives us better
+	 * chances of achieving a perfect/integer value for DEC_RATE. The math here is:
+	 *	1. lcm of the input clock and the desired output rate.
+	 *	2. get the highest multiple of the previous result lower than the adis max rate.
+	 *	3. The last result becomes the IMU sample rate. Use that to calculate SYNC_SCALE
+	 *	   and DEC_RATE (to get the user output rate)
 	 */
 	if (st->clk_mode == ADIS16480_CLK_PPS) {
-		t = t / st->clk_freq;
-		reg = ADIS16495_REG_SYNC_SCALE;
-	} else {
-		t = st->clk_freq / t;
-		reg = ADIS16480_REG_DEC_RATE;
+		unsigned long scaled_rate = lcm(st->clk_freq, t);
+		int sync_scale;
+		struct device *dev = &st->adis.spi->dev;
+
+		/*
+		 * If lcm is bigger than the IMU maximum sampling rate there's no perfect
+		 * solution. In this case, we get the highest multiple of the input clock
+		 * lower that the IMU max sample rate.
+		 */
+		if (scaled_rate > st->chip_info->int_clk)
+			scaled_rate = st->chip_info->int_clk / st->clk_freq * st->clk_freq;
+		else
+			scaled_rate = st->chip_info->int_clk / scaled_rate * scaled_rate;
+
+		/*
+		 * This is not an hard requirement but it's not advised to run the IMU
+		 * with a sample rate lower than 4000Hz due to possible undersampling
+		 * issues so we will log a warning here. We could even force the rate
+		 * to 4000 but some users might really want this...
+		 */
+		if (scaled_rate < 4000000)
+			dev_warn(dev, "Possible undersampling issues due to sampling rate=%lu < 4000\n",
+				 scaled_rate / 1000);
+
+		sync_scale = scaled_rate / st->clk_freq;
+		ret = __adis_write_reg_16(&st->adis, ADIS16495_REG_SYNC_SCALE, sync_scale);
+		if (ret)
+			goto error;
+
+		sample_rate = scaled_rate;
 	}
 
+	t = DIV_ROUND_CLOSEST(sample_rate, t);
+	if (t)
+		t--;
+
 	if (t > st->chip_info->max_dec_rate)
 		t = st->chip_info->max_dec_rate;
 
-	if ((t != 0) && (st->clk_mode != ADIS16480_CLK_PPS))
-		t--;
-
-	return adis_write_reg_16(&st->adis, reg, t);
+	ret = __adis_write_reg_16(&st->adis, ADIS16480_REG_DEC_RATE, t);
+error:
+	adis_dev_unlock(&st->adis);
+	return ret;
 }
 
 static int adis16480_get_freq(struct iio_dev *indio_dev, int *val, int *val2)
@@ -350,34 +387,35 @@ static int adis16480_get_freq(struct iio_dev *indio_dev, int *val, int *val2)
 	struct adis16480 *st = iio_priv(indio_dev);
 	uint16_t t;
 	int ret;
-	unsigned int freq;
-	unsigned int reg;
+	unsigned int freq, sample_rate = st->clk_freq;
 
-	if (st->clk_mode == ADIS16480_CLK_PPS)
-		reg = ADIS16495_REG_SYNC_SCALE;
-	else
-		reg = ADIS16480_REG_DEC_RATE;
+	adis_dev_lock(&st->adis);
 
-	ret = adis_read_reg_16(&st->adis, reg, &t);
+	if (st->clk_mode == ADIS16480_CLK_PPS) {
+		u16 sync_scale;
+
+		ret = __adis_read_reg_16(&st->adis, ADIS16495_REG_SYNC_SCALE, &sync_scale);
+		if (ret)
+			goto error;
+
+		sample_rate = st->clk_freq * sync_scale;
+	}
+
+	ret = __adis_read_reg_16(&st->adis, ADIS16480_REG_DEC_RATE, &t);
 	if (ret)
-		return ret;
+		goto error;
 
-	/*
-	 * When using PPS mode, the rate of data collection is equal to the
-	 * product of the external clock frequency and the scale factor in the
-	 * SYNC_SCALE register.
-	 * When using sync mode, or internal clock, the output data rate is
-	 * equal with  the clock frequency divided by DEC_RATE + 1.
-	 */
-	if (st->clk_mode == ADIS16480_CLK_PPS)
-		freq = st->clk_freq * t;
-	else
-		freq = st->clk_freq / (t + 1);
+	adis_dev_unlock(&st->adis);
+
+	freq = DIV_ROUND_CLOSEST(sample_rate, (t + 1));
 
 	*val = freq / 1000;
 	*val2 = (freq % 1000) * 1000;
 
 	return IIO_VAL_INT_PLUS_MICRO;
+error:
+	adis_dev_unlock(&st->adis);
+	return ret;
 }
 
 enum {
@@ -1278,6 +1316,20 @@ static int adis16480_probe(struct spi_device *spi)
 
 		st->clk_freq = clk_get_rate(st->ext_clk);
 		st->clk_freq *= 1000; /* micro */
+		if (st->clk_mode == ADIS16480_CLK_PPS) {
+			u16 sync_scale;
+
+			/*
+			 * In PPS mode, the IMU sample rate is the clk_freq * sync_scale. Hence,
+			 * default the IMU sample rate to the highest multiple of the input clock
+			 * lower than the IMU max sample rate. The internal sample rate is the
+			 * max...
+			 */
+			sync_scale = st->chip_info->int_clk / st->clk_freq;
+			ret = __adis_write_reg_16(&st->adis, ADIS16495_REG_SYNC_SCALE, sync_scale);
+			if (ret)
+				return ret;
+		}
 	} else {
 		st->clk_freq = st->chip_info->int_clk;
 	}
Signature · 1 line
2.30.0
maintainer
#5 lore raw

Re: [PATCH 2/4] iio: adis16480: fix pps mode sampling frequency math

Quoted 13 lines · On Thu, 21 Jan 2021 12:49:52 +0100 Nuno Sá <[email protected]> wrote:

When using PPS mode, the input clock needs to be scaled so that we have an IMU sample rate between (optimally) 4000 and 4250. After this, we can use the decimation filter to lower the sampling rate in order to get what the user wants. Optimally, the user sample rate is a multiple of both the IMU sample rate and the input clock. Hence, calculating the sync_scale dynamically gives us better chances of achieving a perfect/integer value for DEC_RATE. The math here is:
1. lcm of the input clock and the desired output rate.
2. get the highest multiple of the previous result lower than the adis max rate.
3. The last result becomes the IMU sample rate. Use that to calculate SYNC_SCALE and DEC_RATE (to get the user output rate).

Quoted 2 lines
Fixes 326e2357553d3 ("iio: imu: adis16480: Add support for external clock")

As this is a fix, please move the refactor of the lock to after this patch. We don't really want to need to backport that patch in order to apply this to older kernels.

I'll reply to the cover letter as to what might make sense to do for the case where we are potentially running the sensor too slow.

Otherwise, patch looks fine to me.

Jonathan

Quoted 180 lines
---
 drivers/iio/imu/adis16480.c | 120 ++++++++++++++++++++++++++----------
 1 file changed, 86 insertions(+), 34 deletions(-)
drivers/iio/imu/adis16480.c +86 -34
index dfe86c589325..7620822f3350 100644
@@ -17,6 +17,7 @@
 #include <linux/slab.h>
 #include <linux/sysfs.h>
 #include <linux/module.h>
+#include <linux/lcm.h>
 
 #include <linux/iio/iio.h>
 #include <linux/iio/sysfs.h>
@@ -312,7 +313,8 @@ static int adis16480_debugfs_init(struct iio_dev *indio_dev)
 static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int val2)
 {
 	struct adis16480 *st = iio_priv(indio_dev);
-	unsigned int t, reg;
+	unsigned int t, sample_rate = st->clk_freq;
+	int ret;
 
 	if (val < 0 || val2 < 0)
 		return -EINVAL;
@@ -321,28 +323,63 @@ static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int val2)
 	if (t == 0)
 		return -EINVAL;
 
+	adis_dev_lock(&st->adis);
 	/*
-	 * When using PPS mode, the rate of data collection is equal to the
-	 * product of the external clock frequency and the scale factor in the
-	 * SYNC_SCALE register.
-	 * When using sync mode, or internal clock, the output data rate is
-	 * equal with  the clock frequency divided by DEC_RATE + 1.
+	 * When using PPS mode, the input clock needs to be scaled so that we have an IMU
+	 * sample rate between (optimally) 4000 and 4250. After this, we can use the
+	 * decimation filter to lower the sampling rate in order to get what the user wants.
+	 * Optimally, the user sample rate is a multiple of both the IMU sample rate and
+	 * the input clock. Hence, calculating the sync_scale dynamically gives us better
+	 * chances of achieving a perfect/integer value for DEC_RATE. The math here is:
+	 *	1. lcm of the input clock and the desired output rate.
+	 *	2. get the highest multiple of the previous result lower than the adis max rate.
+	 *	3. The last result becomes the IMU sample rate. Use that to calculate SYNC_SCALE
+	 *	   and DEC_RATE (to get the user output rate)
 	 */
 	if (st->clk_mode == ADIS16480_CLK_PPS) {
-		t = t / st->clk_freq;
-		reg = ADIS16495_REG_SYNC_SCALE;
-	} else {
-		t = st->clk_freq / t;
-		reg = ADIS16480_REG_DEC_RATE;
+		unsigned long scaled_rate = lcm(st->clk_freq, t);
+		int sync_scale;
+		struct device *dev = &st->adis.spi->dev;
+
+		/*
+		 * If lcm is bigger than the IMU maximum sampling rate there's no perfect
+		 * solution. In this case, we get the highest multiple of the input clock
+		 * lower that the IMU max sample rate.
+		 */
+		if (scaled_rate > st->chip_info->int_clk)
+			scaled_rate = st->chip_info->int_clk / st->clk_freq * st->clk_freq;
+		else
+			scaled_rate = st->chip_info->int_clk / scaled_rate * scaled_rate;
+
+		/*
+		 * This is not an hard requirement but it's not advised to run the IMU
+		 * with a sample rate lower than 4000Hz due to possible undersampling
+		 * issues so we will log a warning here. We could even force the rate
+		 * to 4000 but some users might really want this...
+		 */
+		if (scaled_rate < 4000000)
+			dev_warn(dev, "Possible undersampling issues due to sampling rate=%lu < 4000\n",
+				 scaled_rate / 1000);
+
+		sync_scale = scaled_rate / st->clk_freq;
+		ret = __adis_write_reg_16(&st->adis, ADIS16495_REG_SYNC_SCALE, sync_scale);
+		if (ret)
+			goto error;
+
+		sample_rate = scaled_rate;
 	}
 
+	t = DIV_ROUND_CLOSEST(sample_rate, t);
+	if (t)
+		t--;
+
 	if (t > st->chip_info->max_dec_rate)
 		t = st->chip_info->max_dec_rate;
 
-	if ((t != 0) && (st->clk_mode != ADIS16480_CLK_PPS))
-		t--;
-
-	return adis_write_reg_16(&st->adis, reg, t);
+	ret = __adis_write_reg_16(&st->adis, ADIS16480_REG_DEC_RATE, t);
+error:
+	adis_dev_unlock(&st->adis);
+	return ret;
 }
 
 static int adis16480_get_freq(struct iio_dev *indio_dev, int *val, int *val2)
@@ -350,34 +387,35 @@ static int adis16480_get_freq(struct iio_dev *indio_dev, int *val, int *val2)
 	struct adis16480 *st = iio_priv(indio_dev);
 	uint16_t t;
 	int ret;
-	unsigned int freq;
-	unsigned int reg;
+	unsigned int freq, sample_rate = st->clk_freq;
 
-	if (st->clk_mode == ADIS16480_CLK_PPS)
-		reg = ADIS16495_REG_SYNC_SCALE;
-	else
-		reg = ADIS16480_REG_DEC_RATE;
+	adis_dev_lock(&st->adis);
 
-	ret = adis_read_reg_16(&st->adis, reg, &t);
+	if (st->clk_mode == ADIS16480_CLK_PPS) {
+		u16 sync_scale;
+
+		ret = __adis_read_reg_16(&st->adis, ADIS16495_REG_SYNC_SCALE, &sync_scale);
+		if (ret)
+			goto error;
+
+		sample_rate = st->clk_freq * sync_scale;
+	}
+
+	ret = __adis_read_reg_16(&st->adis, ADIS16480_REG_DEC_RATE, &t);
 	if (ret)
-		return ret;
+		goto error;
 
-	/*
-	 * When using PPS mode, the rate of data collection is equal to the
-	 * product of the external clock frequency and the scale factor in the
-	 * SYNC_SCALE register.
-	 * When using sync mode, or internal clock, the output data rate is
-	 * equal with  the clock frequency divided by DEC_RATE + 1.
-	 */
-	if (st->clk_mode == ADIS16480_CLK_PPS)
-		freq = st->clk_freq * t;
-	else
-		freq = st->clk_freq / (t + 1);
+	adis_dev_unlock(&st->adis);
+
+	freq = DIV_ROUND_CLOSEST(sample_rate, (t + 1));
 
 	*val = freq / 1000;
 	*val2 = (freq % 1000) * 1000;
 
 	return IIO_VAL_INT_PLUS_MICRO;
+error:
+	adis_dev_unlock(&st->adis);
+	return ret;
 }
 
 enum {
@@ -1278,6 +1316,20 @@ static int adis16480_probe(struct spi_device *spi)
 
 		st->clk_freq = clk_get_rate(st->ext_clk);
 		st->clk_freq *= 1000; /* micro */
+		if (st->clk_mode == ADIS16480_CLK_PPS) {
+			u16 sync_scale;
+
+			/*
+			 * In PPS mode, the IMU sample rate is the clk_freq * sync_scale. Hence,
+			 * default the IMU sample rate to the highest multiple of the input clock
+			 * lower than the IMU max sample rate. The internal sample rate is the
+			 * max...
+			 */
+			sync_scale = st->chip_info->int_clk / st->clk_freq;
+			ret = __adis_write_reg_16(&st->adis, ADIS16495_REG_SYNC_SCALE, sync_scale);
+			if (ret)
+				return ret;
+		}
 	} else {
 		st->clk_freq = st->chip_info->int_clk;
 	}
author maintainer
#6 lore raw

RE: [PATCH 2/4] iio: adis16480: fix pps mode sampling frequency math

Quoted 35 lines

From: Jonathan Cameron <[email protected]>
Sent: Sunday, January 24, 2021 2:43 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Rob Herring <[email protected]>; Peter Meerwald-Stadler <[email protected]>; Lars-Peter Clausen <[email protected]>; Hennerich, Michael <[email protected]>; Ardelean, Alexandru <[email protected]>
Subject: Re: [PATCH 2/4] iio: adis16480: fix pps mode sampling frequency math

[External]

Quoted 1 line · On Thu, 21 Jan 2021 12:49:52 +0100 Nuno Sá <[email protected]> wrote:

When using PPS mode, the input clock needs to be scaled so that we

have

Quoted 1 line

an IMU sample rate between (optimally) 4000 and 4250. After this,

we can

Quoted 1 line

use the decimation filter to lower the sampling rate in order to get

what

Quoted 1 line

the user wants. Optimally, the user sample rate is a multiple of both

the

Quoted 1 line

IMU sample rate and the input clock. Hence, calculating the

sync_scale

Quoted 1 line

dynamically gives us better chances of achieving a perfect/integer

value

Quoted 7 lines

for DEC_RATE. The math here is:
1. lcm of the input clock and the desired output rate.
2. get the highest multiple of the previous result lower than the adis max rate.
3. The last result becomes the IMU sample rate. Use that to calculate SYNC_SCALE and DEC_RATE (to get the user output rate).

Quoted 8 lines
Quoted 1 line
Fixes 326e2357553d3 ("iio: imu: adis16480: Add support for external

clock")

Quoted 1 line

As this is a fix, please move the refactor of the lock to after this patch. We don't really want to need to backport that patch in order to apply this
to older kernels.

Hmm, completely missed this... will do that.

- Nuno Sá

Quoted 225 lines

I'll reply to the cover letter as to what might make sense to do for the case where we are potentially running the sensor too slow.

Otherwise, patch looks fine to me.

Jonathan

Quoted 2 lines
---
 drivers/iio/imu/adis16480.c | 120 ++++++++++++++++++++++++++-

---------

drivers/iio/imu/adis16480.c static int adis16480_debugfs_init(struct

Quoted 15 lines
 1 file changed, 86 insertions(+), 34 deletions(-)
drivers/iio/imu/adis16480.c +1 -0
index dfe86c589325..7620822f3350 100644
@@ -17,6 +17,7 @@
 #include <linux/slab.h>
 #include <linux/sysfs.h>
 #include <linux/module.h>
+#include <linux/lcm.h>
 
 #include <linux/iio/iio.h>
 #include <linux/iio/sysfs.h>
@@ -312,7 +313,8 @@ static int adis16480_debugfs_init(struct

iio_dev *indio_dev)

drivers/iio/imu/adis16480.c static int adis16480_debugfs_init(struct · line 313

Quoted 1 line
drivers/iio/imu/adis16480.c +0 -0
 static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int

val2)

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev

Quoted 9 lines
drivers/iio/imu/adis16480.c +2 -1
 {
 	struct adis16480 *st = iio_priv(indio_dev);
-	unsigned int t, reg;
+	unsigned int t, sample_rate = st->clk_freq;
+	int ret;
 
 	if (val < 0 || val2 < 0)
 		return -EINVAL;
@@ -321,28 +323,63 @@ static int adis16480_set_freq(struct iio_dev

*indio_dev, int val, int val2)

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int val2)

Quoted 6 lines
drivers/iio/imu/adis16480.c +1 -1
 	if (t == 0)
 		return -EINVAL;
 
+	adis_dev_lock(&st->adis);
 	/*
-	 * When using PPS mode, the rate of data collection is equal to

the

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 326

Quoted 1 line
drivers/iio/imu/adis16480.c +0 -1
-	 * product of the external clock frequency and the scale factor

in the

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 328

Quoted 2 lines
drivers/iio/imu/adis16480.c +0 -2
-	 * SYNC_SCALE register.
-	 * When using sync mode, or internal clock, the output data

rate is

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 328

Quoted 2 lines
drivers/iio/imu/adis16480.c +1 -1
-	 * equal with  the clock frequency divided by DEC_RATE + 1.
+	 * When using PPS mode, the input clock needs to be scaled so

that we have an IMU

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 329

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+	 * sample rate between (optimally) 4000 and 4250. After this,

we can use the

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 330

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+	 * decimation filter to lower the sampling rate in order to get

what the user wants.

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 331

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+	 * Optimally, the user sample rate is a multiple of both the IMU

sample rate and

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 332

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+	 * the input clock. Hence, calculating the sync_scale dynamically

gives us better

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 333

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+	 * chances of achieving a perfect/integer value for DEC_RATE.

The math here is:

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 335

Quoted 2 lines
drivers/iio/imu/adis16480.c +2 -0
+	 *	1. lcm of the input clock and the desired output rate.
+	 *	2. get the highest multiple of the previous result lower

than the adis max rate.

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 336

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+	 *	3. The last result becomes the IMU sample rate. Use

that to calculate SYNC_SCALE

Quoted 4 lines
drivers/iio/imu/adis16480.c +1 -1
+	 *	   and DEC_RATE (to get the user output rate)
 	 */
 	if (st->clk_mode == ADIS16480_CLK_PPS) {
-		t = t / st->clk_freq;

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int val2)

Quoted 10 lines
drivers/iio/imu/adis16480.c +6 -4
-		reg = ADIS16495_REG_SYNC_SCALE;
-	} else {
-		t = st->clk_freq / t;
-		reg = ADIS16480_REG_DEC_RATE;
+		unsigned long scaled_rate = lcm(st->clk_freq, t);
+		int sync_scale;
+		struct device *dev = &st->adis.spi->dev;
+
+		/*
+		 * If lcm is bigger than the IMU maximum sampling rate

there's no perfect

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 346

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+		 * solution. In this case, we get the highest multiple of

the input clock

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int val2)

Quoted 7 lines
drivers/iio/imu/adis16480.c +6 -0
+		 * lower that the IMU max sample rate.
+		 */
+		if (scaled_rate > st->chip_info->int_clk)
+			scaled_rate = st->chip_info->int_clk / st-
 clk_freq * st->clk_freq;
+		else
+			scaled_rate = st->chip_info->int_clk /

scaled_rate * scaled_rate;

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int val2)

Quoted 3 lines
drivers/iio/imu/adis16480.c +3 -0
+
+		/*
+		 * This is not an hard requirement but it's not advised to

run the IMU

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 357

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+		 * with a sample rate lower than 4000Hz due to possible

undersampling

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 358

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+		 * issues so we will log a warning here. We could even

force the rate

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int val2)

Quoted 4 lines
drivers/iio/imu/adis16480.c +4 -0
+		 * to 4000 but some users might really want this...
+		 */
+		if (scaled_rate < 4000000)
+			dev_warn(dev, "Possible undersampling issues

due to sampling rate=%lu < 4000\n",

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int val2)

Quoted 4 lines
drivers/iio/imu/adis16480.c +4 -0
+				 scaled_rate / 1000);
+
+		sync_scale = scaled_rate / st->clk_freq;
+		ret = __adis_write_reg_16(&st->adis,

ADIS16495_REG_SYNC_SCALE, sync_scale);

Quoted 8 lines
drivers/iio/imu/adis16480.c +6 -0
+		if (ret)
+			goto error;
+
+		sample_rate = scaled_rate;
 	}
 
+	t = DIV_ROUND_CLOSEST(sample_rate, t);
+	if (t)

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int val2)

Quoted 10 lines
drivers/iio/imu/adis16480.c +3 -4
+		t--;
+
 	if (t > st->chip_info->max_dec_rate)
 		t = st->chip_info->max_dec_rate;
 
-	if ((t != 0) && (st->clk_mode != ADIS16480_CLK_PPS))
-		t--;
-
-	return adis_write_reg_16(&st->adis, reg, t);
+	ret = __adis_write_reg_16(&st->adis,

ADIS16480_REG_DEC_RATE, t);

Quoted 6 lines
drivers/iio/imu/adis16480.c +3 -0
+error:
+	adis_dev_unlock(&st->adis);
+	return ret;
 }
 

static int adis16480_get_freq(struct iio_dev *indio_dev, int *val, int

*val2)

drivers/iio/imu/adis16480.c static int adis16480_get_freq(struct iio_dev

Quoted 1 line
drivers/iio/imu/adis16480.c +0 -0
@@ -350,34 +387,35 @@ static int adis16480_get_freq(struct iio_dev

*indio_dev, int *val, int *val2)

Quoted 8 lines
drivers/iio/imu/adis16480.c +1 -3
 	struct adis16480 *st = iio_priv(indio_dev);
 	uint16_t t;
 	int ret;
-	unsigned int freq;
-	unsigned int reg;
+	unsigned int freq, sample_rate = st->clk_freq;
 
-	if (st->clk_mode == ADIS16480_CLK_PPS)

drivers/iio/imu/adis16480.c static int adis16480_get_freq(struct iio_dev *indio_dev, int *val, int *val2)

Quoted 10 lines
drivers/iio/imu/adis16480.c +5 -4
-		reg = ADIS16495_REG_SYNC_SCALE;
-	else
-		reg = ADIS16480_REG_DEC_RATE;
+	adis_dev_lock(&st->adis);
 
-	ret = adis_read_reg_16(&st->adis, reg, &t);
+	if (st->clk_mode == ADIS16480_CLK_PPS) {
+		u16 sync_scale;
+
+		ret = __adis_read_reg_16(&st->adis,

ADIS16495_REG_SYNC_SCALE, &sync_scale);

drivers/iio/imu/adis16480.c static int adis16480_get_freq(struct iio_dev *indio_dev, int *val, int *val2)

Quoted 7 lines
drivers/iio/imu/adis16480.c +7 -0
+		if (ret)
+			goto error;
+
+		sample_rate = st->clk_freq * sync_scale;
+	}
+
+	ret = __adis_read_reg_16(&st->adis,

ADIS16480_REG_DEC_RATE, &t);

drivers/iio/imu/adis16480.c static int adis16480_get_freq(struct iio_dev *indio_dev, int *val, int *val2)

Quoted 6 lines
drivers/iio/imu/adis16480.c +1 -3
 	if (ret)
-		return ret;
+		goto error;
 
-	/*
-	 * When using PPS mode, the rate of data collection is equal to

the

drivers/iio/imu/adis16480.c static int adis16480_get_freq(struct iio_dev · line 367

Quoted 1 line
drivers/iio/imu/adis16480.c +0 -1
-	 * product of the external clock frequency and the scale factor

in the

drivers/iio/imu/adis16480.c static int adis16480_get_freq(struct iio_dev · line 369

Quoted 2 lines
drivers/iio/imu/adis16480.c +0 -2
-	 * SYNC_SCALE register.
-	 * When using sync mode, or internal clock, the output data

rate is

drivers/iio/imu/adis16480.c static int adis16480_probe(struct

Quoted 21 lines
drivers/iio/imu/adis16480.c +6 -6
-	 * equal with  the clock frequency divided by DEC_RATE + 1.
-	 */
-	if (st->clk_mode == ADIS16480_CLK_PPS)
-		freq = st->clk_freq * t;
-	else
-		freq = st->clk_freq / (t + 1);
+	adis_dev_unlock(&st->adis);
+
+	freq = DIV_ROUND_CLOSEST(sample_rate, (t + 1));
 
 	*val = freq / 1000;
 	*val2 = (freq % 1000) * 1000;
 
 	return IIO_VAL_INT_PLUS_MICRO;
+error:
+	adis_dev_unlock(&st->adis);
+	return ret;
 }
 
 enum {
@@ -1278,6 +1316,20 @@ static int adis16480_probe(struct

spi_device *spi)

drivers/iio/imu/adis16480.c static int adis16480_probe(struct spi_device *spi)

Quoted 8 lines
drivers/iio/imu/adis16480.c +5 -0
 		st->clk_freq = clk_get_rate(st->ext_clk);
 		st->clk_freq *= 1000; /* micro */
+		if (st->clk_mode == ADIS16480_CLK_PPS) {
+			u16 sync_scale;
+
+			/*
+			 * In PPS mode, the IMU sample rate is the

clk_freq * sync_scale. Hence,

drivers/iio/imu/adis16480.c static int adis16480_probe(struct · line 1323

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+			 * default the IMU sample rate to the highest

multiple of the input clock

drivers/iio/imu/adis16480.c static int adis16480_probe(struct · line 1324

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+			 * lower than the IMU max sample rate. The

internal sample rate is the

drivers/iio/imu/adis16480.c static int adis16480_probe(struct · line 1329

Quoted 5 lines
drivers/iio/imu/adis16480.c +4 -0
+			 * max...
+			 */
+			sync_scale = st->chip_info->int_clk / st-
 clk_freq;
+			ret = __adis_write_reg_16(&st->adis,

ADIS16495_REG_SYNC_SCALE, sync_scale);

Quoted 6 lines
drivers/iio/imu/adis16480.c +3 -0
+			if (ret)
+				return ret;
+		}
 	} else {
 		st->clk_freq = st->chip_info->int_clk;
 	}
author maintainer
#7 lore raw

RE: [PATCH 2/4] iio: adis16480: fix pps mode sampling frequency math

In reply to Jonathan Cameron
Quoted 37 lines

-----Original Message-----
From: Jonathan Cameron <[email protected]>
Sent: Sunday, January 24, 2021 2:43 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Rob Herring <[email protected]>; Peter Meerwald-Stadler <[email protected]>; Lars-Peter Clausen <[email protected]>; Hennerich, Michael <[email protected]>; Ardelean, Alexandru <[email protected]>
Subject: Re: [PATCH 2/4] iio: adis16480: fix pps mode sampling frequency math

[External]

Quoted 1 line · On Thu, 21 Jan 2021 12:49:52 +0100 Nuno Sá <[email protected]> wrote:

When using PPS mode, the input clock needs to be scaled so that we

have

Quoted 1 line

an IMU sample rate between (optimally) 4000 and 4250. After this,

we can

Quoted 1 line

use the decimation filter to lower the sampling rate in order to get

what

Quoted 1 line

the user wants. Optimally, the user sample rate is a multiple of both

the

Quoted 1 line

IMU sample rate and the input clock. Hence, calculating the

sync_scale

Quoted 1 line

dynamically gives us better chances of achieving a perfect/integer

value

Quoted 7 lines

for DEC_RATE. The math here is:
1. lcm of the input clock and the desired output rate.
2. get the highest multiple of the previous result lower than the adis max rate.
3. The last result becomes the IMU sample rate. Use that to calculate SYNC_SCALE and DEC_RATE (to get the user output rate).

Quoted 8 lines
Quoted 1 line
Fixes 326e2357553d3 ("iio: imu: adis16480: Add support for external

clock")

Quoted 1 line

As this is a fix, please move the refactor of the lock to after this patch. We don't really want to need to backport that patch in order to apply this
to older kernels.

Hmm, completely missed this... will do that.

- Nuno Sá

Quoted 225 lines

I'll reply to the cover letter as to what might make sense to do for the case where we are potentially running the sensor too slow.

Otherwise, patch looks fine to me.

Jonathan

Quoted 2 lines
---
 drivers/iio/imu/adis16480.c | 120 ++++++++++++++++++++++++++-

---------

drivers/iio/imu/adis16480.c static int adis16480_debugfs_init(struct

Quoted 15 lines
 1 file changed, 86 insertions(+), 34 deletions(-)
drivers/iio/imu/adis16480.c +1 -0
index dfe86c589325..7620822f3350 100644
@@ -17,6 +17,7 @@
 #include <linux/slab.h>
 #include <linux/sysfs.h>
 #include <linux/module.h>
+#include <linux/lcm.h>
 
 #include <linux/iio/iio.h>
 #include <linux/iio/sysfs.h>
@@ -312,7 +313,8 @@ static int adis16480_debugfs_init(struct

iio_dev *indio_dev)

drivers/iio/imu/adis16480.c static int adis16480_debugfs_init(struct · line 313

Quoted 1 line
drivers/iio/imu/adis16480.c +0 -0
 static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int

val2)

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev

Quoted 9 lines
drivers/iio/imu/adis16480.c +2 -1
 {
 	struct adis16480 *st = iio_priv(indio_dev);
-	unsigned int t, reg;
+	unsigned int t, sample_rate = st->clk_freq;
+	int ret;
 
 	if (val < 0 || val2 < 0)
 		return -EINVAL;
@@ -321,28 +323,63 @@ static int adis16480_set_freq(struct iio_dev

*indio_dev, int val, int val2)

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int val2)

Quoted 6 lines
drivers/iio/imu/adis16480.c +1 -1
 	if (t == 0)
 		return -EINVAL;
 
+	adis_dev_lock(&st->adis);
 	/*
-	 * When using PPS mode, the rate of data collection is equal to

the

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 326

Quoted 1 line
drivers/iio/imu/adis16480.c +0 -1
-	 * product of the external clock frequency and the scale factor

in the

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 328

Quoted 2 lines
drivers/iio/imu/adis16480.c +0 -2
-	 * SYNC_SCALE register.
-	 * When using sync mode, or internal clock, the output data

rate is

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 328

Quoted 2 lines
drivers/iio/imu/adis16480.c +1 -1
-	 * equal with  the clock frequency divided by DEC_RATE + 1.
+	 * When using PPS mode, the input clock needs to be scaled so

that we have an IMU

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 329

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+	 * sample rate between (optimally) 4000 and 4250. After this,

we can use the

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 330

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+	 * decimation filter to lower the sampling rate in order to get

what the user wants.

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 331

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+	 * Optimally, the user sample rate is a multiple of both the IMU

sample rate and

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 332

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+	 * the input clock. Hence, calculating the sync_scale dynamically

gives us better

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 333

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+	 * chances of achieving a perfect/integer value for DEC_RATE.

The math here is:

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 335

Quoted 2 lines
drivers/iio/imu/adis16480.c +2 -0
+	 *	1. lcm of the input clock and the desired output rate.
+	 *	2. get the highest multiple of the previous result lower

than the adis max rate.

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 336

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+	 *	3. The last result becomes the IMU sample rate. Use

that to calculate SYNC_SCALE

Quoted 4 lines
drivers/iio/imu/adis16480.c +1 -1
+	 *	   and DEC_RATE (to get the user output rate)
 	 */
 	if (st->clk_mode == ADIS16480_CLK_PPS) {
-		t = t / st->clk_freq;

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int val2)

Quoted 10 lines
drivers/iio/imu/adis16480.c +6 -4
-		reg = ADIS16495_REG_SYNC_SCALE;
-	} else {
-		t = st->clk_freq / t;
-		reg = ADIS16480_REG_DEC_RATE;
+		unsigned long scaled_rate = lcm(st->clk_freq, t);
+		int sync_scale;
+		struct device *dev = &st->adis.spi->dev;
+
+		/*
+		 * If lcm is bigger than the IMU maximum sampling rate

there's no perfect

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 346

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+		 * solution. In this case, we get the highest multiple of

the input clock

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int val2)

Quoted 7 lines
drivers/iio/imu/adis16480.c +6 -0
+		 * lower that the IMU max sample rate.
+		 */
+		if (scaled_rate > st->chip_info->int_clk)
+			scaled_rate = st->chip_info->int_clk / st-
 clk_freq * st->clk_freq;
+		else
+			scaled_rate = st->chip_info->int_clk /

scaled_rate * scaled_rate;

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int val2)

Quoted 3 lines
drivers/iio/imu/adis16480.c +3 -0
+
+		/*
+		 * This is not an hard requirement but it's not advised to

run the IMU

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 357

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+		 * with a sample rate lower than 4000Hz due to possible

undersampling

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev · line 358

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+		 * issues so we will log a warning here. We could even

force the rate

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int val2)

Quoted 4 lines
drivers/iio/imu/adis16480.c +4 -0
+		 * to 4000 but some users might really want this...
+		 */
+		if (scaled_rate < 4000000)
+			dev_warn(dev, "Possible undersampling issues

due to sampling rate=%lu < 4000\n",

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int val2)

Quoted 4 lines
drivers/iio/imu/adis16480.c +4 -0
+				 scaled_rate / 1000);
+
+		sync_scale = scaled_rate / st->clk_freq;
+		ret = __adis_write_reg_16(&st->adis,

ADIS16495_REG_SYNC_SCALE, sync_scale);

Quoted 8 lines
drivers/iio/imu/adis16480.c +6 -0
+		if (ret)
+			goto error;
+
+		sample_rate = scaled_rate;
 	}
 
+	t = DIV_ROUND_CLOSEST(sample_rate, t);
+	if (t)

drivers/iio/imu/adis16480.c static int adis16480_set_freq(struct iio_dev *indio_dev, int val, int val2)

Quoted 10 lines
drivers/iio/imu/adis16480.c +3 -4
+		t--;
+
 	if (t > st->chip_info->max_dec_rate)
 		t = st->chip_info->max_dec_rate;
 
-	if ((t != 0) && (st->clk_mode != ADIS16480_CLK_PPS))
-		t--;
-
-	return adis_write_reg_16(&st->adis, reg, t);
+	ret = __adis_write_reg_16(&st->adis,

ADIS16480_REG_DEC_RATE, t);

Quoted 6 lines
drivers/iio/imu/adis16480.c +3 -0
+error:
+	adis_dev_unlock(&st->adis);
+	return ret;
 }
 

static int adis16480_get_freq(struct iio_dev *indio_dev, int *val, int

*val2)

drivers/iio/imu/adis16480.c static int adis16480_get_freq(struct iio_dev

Quoted 1 line
drivers/iio/imu/adis16480.c +0 -0
@@ -350,34 +387,35 @@ static int adis16480_get_freq(struct iio_dev

*indio_dev, int *val, int *val2)

Quoted 8 lines
drivers/iio/imu/adis16480.c +1 -3
 	struct adis16480 *st = iio_priv(indio_dev);
 	uint16_t t;
 	int ret;
-	unsigned int freq;
-	unsigned int reg;
+	unsigned int freq, sample_rate = st->clk_freq;
 
-	if (st->clk_mode == ADIS16480_CLK_PPS)

drivers/iio/imu/adis16480.c static int adis16480_get_freq(struct iio_dev *indio_dev, int *val, int *val2)

Quoted 10 lines
drivers/iio/imu/adis16480.c +5 -4
-		reg = ADIS16495_REG_SYNC_SCALE;
-	else
-		reg = ADIS16480_REG_DEC_RATE;
+	adis_dev_lock(&st->adis);
 
-	ret = adis_read_reg_16(&st->adis, reg, &t);
+	if (st->clk_mode == ADIS16480_CLK_PPS) {
+		u16 sync_scale;
+
+		ret = __adis_read_reg_16(&st->adis,

ADIS16495_REG_SYNC_SCALE, &sync_scale);

drivers/iio/imu/adis16480.c static int adis16480_get_freq(struct iio_dev *indio_dev, int *val, int *val2)

Quoted 7 lines
drivers/iio/imu/adis16480.c +7 -0
+		if (ret)
+			goto error;
+
+		sample_rate = st->clk_freq * sync_scale;
+	}
+
+	ret = __adis_read_reg_16(&st->adis,

ADIS16480_REG_DEC_RATE, &t);

drivers/iio/imu/adis16480.c static int adis16480_get_freq(struct iio_dev *indio_dev, int *val, int *val2)

Quoted 6 lines
drivers/iio/imu/adis16480.c +1 -3
 	if (ret)
-		return ret;
+		goto error;
 
-	/*
-	 * When using PPS mode, the rate of data collection is equal to

the

drivers/iio/imu/adis16480.c static int adis16480_get_freq(struct iio_dev · line 367

Quoted 1 line
drivers/iio/imu/adis16480.c +0 -1
-	 * product of the external clock frequency and the scale factor

in the

drivers/iio/imu/adis16480.c static int adis16480_get_freq(struct iio_dev · line 369

Quoted 2 lines
drivers/iio/imu/adis16480.c +0 -2
-	 * SYNC_SCALE register.
-	 * When using sync mode, or internal clock, the output data

rate is

drivers/iio/imu/adis16480.c static int adis16480_probe(struct

Quoted 21 lines
drivers/iio/imu/adis16480.c +6 -6
-	 * equal with  the clock frequency divided by DEC_RATE + 1.
-	 */
-	if (st->clk_mode == ADIS16480_CLK_PPS)
-		freq = st->clk_freq * t;
-	else
-		freq = st->clk_freq / (t + 1);
+	adis_dev_unlock(&st->adis);
+
+	freq = DIV_ROUND_CLOSEST(sample_rate, (t + 1));
 
 	*val = freq / 1000;
 	*val2 = (freq % 1000) * 1000;
 
 	return IIO_VAL_INT_PLUS_MICRO;
+error:
+	adis_dev_unlock(&st->adis);
+	return ret;
 }
 
 enum {
@@ -1278,6 +1316,20 @@ static int adis16480_probe(struct

spi_device *spi)

drivers/iio/imu/adis16480.c static int adis16480_probe(struct spi_device *spi)

Quoted 8 lines
drivers/iio/imu/adis16480.c +5 -0
 		st->clk_freq = clk_get_rate(st->ext_clk);
 		st->clk_freq *= 1000; /* micro */
+		if (st->clk_mode == ADIS16480_CLK_PPS) {
+			u16 sync_scale;
+
+			/*
+			 * In PPS mode, the IMU sample rate is the

clk_freq * sync_scale. Hence,

drivers/iio/imu/adis16480.c static int adis16480_probe(struct · line 1323

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+			 * default the IMU sample rate to the highest

multiple of the input clock

drivers/iio/imu/adis16480.c static int adis16480_probe(struct · line 1324

Quoted 1 line
drivers/iio/imu/adis16480.c +1 -0
+			 * lower than the IMU max sample rate. The

internal sample rate is the

drivers/iio/imu/adis16480.c static int adis16480_probe(struct · line 1329

Quoted 5 lines
drivers/iio/imu/adis16480.c +4 -0
+			 * max...
+			 */
+			sync_scale = st->chip_info->int_clk / st-
 clk_freq;
+			ret = __adis_write_reg_16(&st->adis,

ADIS16495_REG_SYNC_SCALE, sync_scale);

Quoted 6 lines
drivers/iio/imu/adis16480.c +3 -0
+			if (ret)
+				return ret;
+		}
 	} else {
 		st->clk_freq = st->chip_info->int_clk;
 	}
author maintainer
#8 lore raw

PATCH 3/4 iio: adis16475: improve sync scale mode handling

In reply to Nuno Sá

With this patch, we don't force users to define the IMU scaled internal sampling rate once in the devicetree. Now it's dynamically calculated at runtime depending on the desired output rate given by users.

Calculating the sync_scale dynamically gives us better chances of achieving a perfect/integer value for DEC_RATE (thus giving more flexibility). The math is:
1. lcm of the input clock and the desired output rate.
2. get the highest multiple of the previous result lower than the adis max rate.
3. The last result becomes the IMU sample rate. Use that to calculate SYNC_SCALE and DEC_RATE (to get the user output rate).

---
 drivers/iio/imu/adis16475.c | 110 +++++++++++++++++++++++++++---------
 1 file changed, 82 insertions(+), 28 deletions(-)
drivers/iio/imu/adis16475.c +82 -28
index 197d48240991..cd44226d0672 100644
@@ -17,6 +17,7 @@
 #include <linux/iio/sysfs.h>
 #include <linux/iio/trigger_consumer.h>
 #include <linux/irq.h>
+#include <linux/lcm.h>
 #include <linux/module.h>
 #include <linux/mod_devicetable.h>
 #include <linux/property.h>
@@ -101,6 +102,7 @@ struct adis16475 {
 	u32 clk_freq;
 	bool burst32;
 	unsigned long lsb_flag;
+	u16 sync_mode;
 	/* Alignment needed for the timestamp */
 	__be16 data[ADIS16475_MAX_SCAN_DATA] __aligned(8);
 };
@@ -253,25 +255,90 @@ static int adis16475_get_freq(struct adis16475 *st, u32 *freq)
 {
 	int ret;
 	u16 dec;
+	u32 sample_rate = st->clk_freq;
+
+	adis_dev_lock(&st->adis);
+
+	if (st->sync_mode == ADIS16475_SYNC_SCALED) {
+		u16 sync_scale;
+
+		ret = __adis_read_reg_16(&st->adis, ADIS16475_REG_UP_SCALE, &sync_scale);
+		if (ret)
+			goto error;
+
+		sample_rate = st->clk_freq * sync_scale;
+	}
 
-	ret = adis_read_reg_16(&st->adis, ADIS16475_REG_DEC_RATE, &dec);
+	ret = __adis_read_reg_16(&st->adis, ADIS16475_REG_DEC_RATE, &dec);
 	if (ret)
-		return -EINVAL;
+		goto error;
+
+	adis_dev_unlock(&st->adis);
 
-	*freq = DIV_ROUND_CLOSEST(st->clk_freq, dec + 1);
+	*freq = DIV_ROUND_CLOSEST(sample_rate, dec + 1);
 
 	return 0;
+error:
+	adis_dev_unlock(&st->adis);
+	return ret;
 }
 
 static int adis16475_set_freq(struct adis16475 *st, const u32 freq)
 {
 	u16 dec;
 	int ret;
+	u32 sample_rate = st->clk_freq;
 
 	if (!freq)
 		return -EINVAL;
 
-	dec = DIV_ROUND_CLOSEST(st->clk_freq, freq);
+	adis_dev_lock(&st->adis);
+	/*
+	 * When using sync scaled mode, the input clock needs to be scaled so that we have
+	 * an IMU sample rate between (optimally) 1900 and 2100. After this, we can use the
+	 * decimation filter to lower the sampling rate in order to get what the user wants.
+	 * Optimally, the user sample rate is a multiple of both the IMU sample rate and
+	 * the input clock. Hence, calculating the sync_scale dynamically gives us better
+	 * chances of achieving a perfect/integer value for DEC_RATE. The math here is:
+	 *	1. lcm of the input clock and the desired output rate.
+	 *	2. get the highest multiple of the previous result lower than the adis max rate.
+	 *	3. The last result becomes the IMU sample rate. Use that to calculate SYNC_SCALE
+	 *	   and DEC_RATE (to get the user output rate)
+	 */
+	if (st->sync_mode == ADIS16475_SYNC_SCALED) {
+		unsigned long scaled_rate = lcm(st->clk_freq, freq);
+		int sync_scale;
+		struct device *dev = &st->adis.spi->dev;
+
+		/*
+		 * If lcm is bigger than the IMU maximum sampling rate there's no perfect
+		 * solution. In this case, we get the highest multiple of the input clock
+		 * lower that the IMU max sample rate.
+		 */
+		if (scaled_rate > 2100000)
+			scaled_rate = 2100000 / st->clk_freq * st->clk_freq;
+		else
+			scaled_rate = 2100000 / scaled_rate * scaled_rate;
+
+		/*
+		 * This is not an hard requirement but it's not advised to run the IMU
+		 * with a sample rate lower than 1900Hz due to possible undersampling
+		 * issues so we will log a warning here. We could even force the rate
+		 * to 1900 but some users might really want this...
+		 */
+		if (scaled_rate < 1900000)
+			dev_warn(dev, "Possible undersampling issues due to sampling rate=%lu < 1900\n",
+				 scaled_rate / 1000);
+
+		sync_scale = scaled_rate / st->clk_freq;
+		ret = __adis_write_reg_16(&st->adis, ADIS16475_REG_UP_SCALE, sync_scale);
+		if (ret)
+			goto error;
+
+		sample_rate = scaled_rate;
+	}
+
+	dec = DIV_ROUND_CLOSEST(sample_rate, freq);
 
 	if (dec)
 		dec--;
@@ -281,7 +348,7 @@ static int adis16475_set_freq(struct adis16475 *st, const u32 freq)
 
 	ret = adis_write_reg_16(&st->adis, ADIS16475_REG_DEC_RATE, dec);
 	if (ret)
-		return ret;
+		goto error;
 
 	/*
 	 * If decimation is used, then gyro and accel data will have meaningful
@@ -290,6 +357,9 @@ static int adis16475_set_freq(struct adis16475 *st, const u32 freq)
 	assign_bit(ADIS16475_LSB_DEC_MASK, &st->lsb_flag, dec);
 
 	return 0;
+error:
+	adis_dev_unlock(&st->adis);
+	return ret;
 }
 
 /* The values are approximated. */
@@ -1085,6 +1155,7 @@ static int adis16475_config_sync_mode(struct adis16475 *st)
 	}
 
 	sync = &st->info->sync[sync_mode];
+	st->sync_mode = sync->sync_mode;
 
 	/* All the other modes require external input signal */
 	if (sync->sync_mode != ADIS16475_SYNC_OUTPUT) {
@@ -1112,37 +1183,20 @@ static int adis16475_config_sync_mode(struct adis16475 *st)
 
 		if (sync->sync_mode == ADIS16475_SYNC_SCALED) {
 			u16 up_scale;
-			u32 scaled_out_freq = 0;
+
 			/*
-			 * If we are in scaled mode, we must have an up_scale.
-			 * In scaled mode the allowable input clock range is
-			 * 1 Hz to 128 Hz, and the allowable output range is
-			 * 1900 to 2100 Hz. Hence, a scale must be given to
-			 * get the allowable output.
+			 * In sync scaled mode, the IMU sample rate is the clk_freq * sync_scale.
+			 * Hence, default the IMU sample rate to the highest multiple of the input
+			 * clock lower than the IMU max sample rate. The optimal range is
+			 * 1900-2100 sps...
 			 */
-			ret = device_property_read_u32(dev,
-						       "adi,scaled-output-hz",
-						       &scaled_out_freq);
-			if (ret) {
-				dev_err(dev, "adi,scaled-output-hz must be given when in scaled sync mode");
-				return -EINVAL;
-			} else if (scaled_out_freq < 1900 ||
-				   scaled_out_freq > 2100) {
-				dev_err(dev, "Invalid value: %u for adi,scaled-output-hz",
-					scaled_out_freq);
-				return -EINVAL;
-			}
-
-			up_scale = DIV_ROUND_CLOSEST(scaled_out_freq,
-						     st->clk_freq);
+			up_scale = 2100 / st->clk_freq;
 
 			ret = __adis_write_reg_16(&st->adis,
 						  ADIS16475_REG_UP_SCALE,
 						  up_scale);
 			if (ret)
 				return ret;
-
-			st->clk_freq = scaled_out_freq;
 		}
 
 		st->clk_freq *= 1000;
Signature · 1 line
2.30.0
author maintainer
#9 lore raw

PATCH 4/4 dt-bindings: adis16475: remove property

In reply to Nuno Sá

adi,scaled-output-hz is no longer used by the driver.

---
 .../devicetree/bindings/iio/imu/adi,adis16475.yaml       | 9 ---------
 1 file changed, 9 deletions(-)
Documentation/devicetree/bindings/iio/imu/adi,adis16475.yaml +0 -9
index 79fba1508e89..a7574210175a 100644
@@ -71,15 +71,6 @@ properties:
     minimum: 0
     maximum: 3
 
-  adi,scaled-output-hz:
-    description:
-      This property must be present if the clock mode is scaled-sync through
-      clock-names property. In this mode, the input clock can have a range
-      of 1Hz to 128HZ which must be scaled to originate an allowable sample
-      rate. This property specifies that rate.
-    minimum: 1900
-    maximum: 2100
-
 required:
   - compatible
   - reg
Signature · 1 line
2.30.0
maintainer
#11 lore raw
In reply to Nuno Sá
Quoted 22 lines · On Thu, 21 Jan 2021 12:49:50 +0100 Nuno Sá <[email protected]> wrote:

The first patch in this series is just a simple helper to lock/unlock the device. Having these helpers make the code slightly neater (IMHO).

The following patches introduces changes in the sampling frequency calculation when sync scale/pps modes are used. First, it's important to understand the purpose of this mode and how it should be used. Let's say our part has an internal rate of 4250 (e.g adis1649x family) and the user wants an output rate of 200SPS. Obviously, we can't use this sampling rate and divide back down to get 200 SPS with decimation on. Hence, we can use this mode to give an input clock of 1HZ, scale it to something like 4200 or 4000 SPS and then use the decimation filter to get the exact desired 200SPS. There are also some limits that should be taken into account when scaling:

* For the devices in the adis16475 driver:
- Input sync frequency range is 1 to 128 Hz
- Native sample rate: 2 kSPS. Optimal range: 1900-2100 sps

* For the adis1649x family (adis16480 driver):
- Input sync frequency range is 1 to 128 Hz
- Native sample rate: 4.25 kSPS. Optimal range: 4000-4250 sps

Quoted 6 lines

I'm not 100% convinced on how to handle the optimal minimum. For now, I'm just throwing a warning saying we might get into trouble if we get a value lower than that. I was also tempted to just return -EINVAL or clamp the value. However, I know that there are ADI customers that (for some reason) are using a sampling rate lower than the minimum advised.

So the opening question I'd have here is how critical is the actual
userspace sampling rate to your users? Often they don't mind
getting a little more data than they asked for (say 200.5Hz when asking for 200) and can always read back the attribute after writing it to discover this has happened.

As such, once you've discovered that value doesn't have an exact match, perhaps tweak the output data rate until it fits nicely? A bit of quick investigation suggests (by my wife who happened to be sat across the room) suggests that you have a hideous set of local minima so your best bet is to brute force search (not that bad and we don't expect to change this a lot!)

Quoted 24 lines

That said, the patch for the adis16480 driver is a fix as this mode was being wrongly handled. There should not be a "separation" between using the sync_scale and the dec_rate registers. The way things were being done, we could easily get into a situation where the part could be running with an internal rate way lower than the optimal minimum.

For the adis16475 drivers, things were not really wrong. They were just not optimal as we were forcing users to specify the IMU scaled internal rate once in the devicetree. Calculating things at runtime gives much more flexibility to choose the output rate.

Nuno Sá (4):
iio: adis: add helpers for locking
iio: adis16480: fix pps mode sampling frequency math
iio: adis16475: improve sync scale mode handling
dt-bindings: adis16475: remove property

 .../bindings/iio/imu/adi,adis16475.yaml       |   9 --
 drivers/iio/imu/adis16475.c                   | 110 ++++++++++++----
 drivers/iio/imu/adis16480.c                   | 120 +++++++++++++-----
 include/linux/iio/imu/adis.h                  |  10 ++
 4 files changed, 178 insertions(+), 71 deletions(-)
author maintainer
#12 lore raw
Quoted 53 lines

-----Original Message-----
From: Jonathan Cameron <[email protected]>
Sent: Sunday, January 24, 2021 3:21 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Rob Herring <[email protected]>; Peter Meerwald-Stadler <[email protected]>; Lars-Peter Clausen <[email protected]>; Hennerich, Michael <[email protected]>; Ardelean, Alexandru <[email protected]>
Subject: Re: [PATCH 0/4] Fix/Improve sync clock mode handling

Quoted 2 lines · On Thu, 21 Jan 2021 12:49:50 +0100 Nuno Sá <[email protected]> wrote:

The first patch in this series is just a simple helper to lock/unlock the device. Having these helpers make the code slightly neater

(IMHO).

Quoted 4 lines

The following patches introduces changes in the sampling frequency calculation when sync scale/pps modes are used. First, it's important to understand the purpose of this mode and how it should be used.

Let's

Quoted 1 line

say our part has an internal rate of 4250 (e.g adis1649x family) and

the

Quoted 2 lines

user wants an output rate of 200SPS. Obviously, we can't use this sampling rate and divide back down to get 200 SPS with decimation

on.

Quoted 2 lines

Hence, we can use this mode to give an input clock of 1HZ, scale it to something like 4200 or 4000 SPS and then use the decimation filter to

get

Quoted 7 lines

the exact desired 200SPS. There are also some limits that should be taken into account when scaling:

* For the devices in the adis16475 driver:
- Input sync frequency range is 1 to 128 Hz
- Native sample rate: 2 kSPS. Optimal range: 1900-2100 sps

Quoted 5 lines

* For the adis1649x family (adis16480 driver):
- Input sync frequency range is 1 to 128 Hz
- Native sample rate: 4.25 kSPS. Optimal range: 4000-4250 sps

I'm not 100% convinced on how to handle the optimal minimum. For

now,

Quoted 1 line

I'm just throwing a warning saying we might get into trouble if we get

a

Quoted 4 lines

value lower than that. I was also tempted to just return -EINVAL or clamp the value. However, I know that there are ADI customers that (for some reason) are using a sampling rate lower than the minimum advised.

Quoted 5 lines

So the opening question I'd have here is how critical is the actual
userspace sampling rate to your users? Often they don't mind
getting a little more data than they asked for (say 200.5Hz when asking for 200) and can always read back the attribute after writing it to discover this has happened.

Well, honestly I'm not really sure here. I can just say (from the info I got internally) that some users are really using these parts with a data rate lower than the advised. However, I'd say that this would depend on the use case. For some critical cases, I would expect that users really want to have an exact sample rate. Though I'd argue that in those cases, they should know what they are doing and provide an output rate that fits nicely (multiple of both the input clock and IMU internal sample rate). And as you said, they can always readback the value to check if they are getting something that is not really what they expect...

Quoted 2 lines

As such, once you've discovered that value doesn't have an exact match, perhaps tweak the output data rate until it fits nicely?

I did thought about this. The reason why I didn't went for it in this first version is because of those who seems to really want to run the part at lower rates. Let's assume we have an input clock of 1HZ and someone writes an output rate of 3000SPS. The only way to accomplish this is to set sync_scale at 3000 and let the IMU run at 3000SPS with decimation off (DEC_RATE=0). If we are going to tweak the output rate to fit nicely, we would have to force it to 4000SPS which is significantly different from the desired 3000SPS.

Quoted 4 lines

A bit of quick investigation suggests (by my wife who happened to be sat across the room) suggests that you have a hideous set of local minima so your best bet is to brute force search (not that bad and we don't expect to change this a lot!)

Hmm, not sure what do you have in mind here :)?

- Nuno Sá

Quoted 29 lines
Quoted 3 lines

That said, the patch for the adis16480 driver is a fix as this mode was being wrongly handled. There should not be a "separation" between

using

Quoted 1 line

the sync_scale and the dec_rate registers. The way things were

being done,

Quoted 1 line

we could easily get into a situation where the part could be running

with

Quoted 3 lines

an internal rate way lower than the optimal minimum.

For the adis16475 drivers, things were not really wrong. They were

just

Quoted 1 line

not optimal as we were forcing users to specify the IMU scaled

internal

Quoted 15 lines

rate once in the devicetree. Calculating things at runtime gives much more flexibility to choose the output rate.

Nuno Sá (4):
iio: adis: add helpers for locking
iio: adis16480: fix pps mode sampling frequency math
iio: adis16475: improve sync scale mode handling
dt-bindings: adis16475: remove property

 .../bindings/iio/imu/adi,adis16475.yaml       |   9 --
 drivers/iio/imu/adis16475.c                   | 110 ++++++++++++----
 drivers/iio/imu/adis16480.c                   | 120 +++++++++++++-----
 include/linux/iio/imu/adis.h                  |  10 ++
 4 files changed, 178 insertions(+), 71 deletions(-)
maintainer
#13 lore raw
Quoted 68 lines · Nuno
Quoted 51 lines

-----Original Message-----
From: Jonathan Cameron <[email protected]>
Sent: Sunday, January 24, 2021 3:21 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Rob Herring <[email protected]>; Peter Meerwald-Stadler <[email protected]>; Lars-Peter Clausen <[email protected]>; Hennerich, Michael <[email protected]>; Ardelean, Alexandru <[email protected]>
Subject: Re: [PATCH 0/4] Fix/Improve sync clock mode handling

Quoted 2 lines · On Thu, 21 Jan 2021 12:49:50 +0100 Nuno Sá <[email protected]> wrote:

The first patch in this series is just a simple helper to lock/unlock the device. Having these helpers make the code slightly neater

(IMHO).

Quoted 4 lines

The following patches introduces changes in the sampling frequency calculation when sync scale/pps modes are used. First, it's important to understand the purpose of this mode and how it should be used.

Let's

Quoted 1 line

say our part has an internal rate of 4250 (e.g adis1649x family) and

the

Quoted 2 lines

user wants an output rate of 200SPS. Obviously, we can't use this sampling rate and divide back down to get 200 SPS with decimation

on.

Quoted 2 lines

Hence, we can use this mode to give an input clock of 1HZ, scale it to something like 4200 or 4000 SPS and then use the decimation filter to

get

Quoted 7 lines

the exact desired 200SPS. There are also some limits that should be taken into account when scaling:

* For the devices in the adis16475 driver:
- Input sync frequency range is 1 to 128 Hz
- Native sample rate: 2 kSPS. Optimal range: 1900-2100 sps

Quoted 5 lines

* For the adis1649x family (adis16480 driver):
- Input sync frequency range is 1 to 128 Hz
- Native sample rate: 4.25 kSPS. Optimal range: 4000-4250 sps

I'm not 100% convinced on how to handle the optimal minimum. For

now,

Quoted 1 line

I'm just throwing a warning saying we might get into trouble if we get

a

Quoted 4 lines

value lower than that. I was also tempted to just return -EINVAL or clamp the value. However, I know that there are ADI customers that (for some reason) are using a sampling rate lower than the minimum advised.

Quoted 5 lines

So the opening question I'd have here is how critical is the actual
userspace sampling rate to your users? Often they don't mind
getting a little more data than they asked for (say 200.5Hz when asking for 200) and can always read back the attribute after writing it to discover this has happened.

Well, honestly I'm not really sure here. I can just say (from the info I got internally) that some users are really using these parts with a data rate lower than the advised. However, I'd say that this would depend on the use case. For some critical cases, I would expect that users really want to have an exact sample rate. Though I'd argue that in those cases, they should know what they are doing and provide an output rate that fits nicely (multiple of both the input clock and IMU internal sample rate). And as you said, they can always readback the value to check if they are getting something that is not really what they expect...

Quoted 2 lines

As such, once you've discovered that value doesn't have an exact match, perhaps tweak the output data rate until it fits nicely?

Quoted 6 lines

I did thought about this. The reason why I didn't went for it in this first version is because of those who seems to really want to run the part at lower rates. Let's assume we have an input clock of 1HZ and someone writes an output rate of 3000SPS. The only way to accomplish this is to set sync_scale at 3000 and let the IMU run at 3000SPS with decimation off (DEC_RATE=0). If we are going to tweak the output rate to fit nicely, we would have to force it to 4000SPS which is significantly different from the desired 3000SPS.

Good point. If someone wants to do that there isn't much we can do to make it work nicely. I'd argue they are wrong and move it to the nearest within the constraints, but that might be rather unexpected for them...

I wonder if we do something ugly like have an extra control to say 'really do what I say even if it's horrible'.
That would mean we'd get what 'most' users expect (I hope) in that it's within the documented range, but provide the control to those who want to do something horrible.. Not nice, what do you think?

Quoted 7 lines
Quoted 5 lines

A bit of quick investigation suggests (by my wife who happened to be sat across the room) suggests that you have a hideous set of local minima so your best bet is to brute force search (not that bad and we don't expect to change this a lot!)

Hmm, not sure what do you have in mind here :)?

You have two controllable parameters both of which are integers. As such there isn't a nice easy 'right' answer for what combination to use. For example, if we have a case where there is no right answer, you will have to search for every possible multiplier, find the best divisor and check how far that is above the desired frequency. Of those find the smallest one (best option given constraints).

Jonathan

Quoted 33 lines

- Nuno Sá

Quoted 29 lines
Quoted 3 lines

That said, the patch for the adis16480 driver is a fix as this mode was being wrongly handled. There should not be a "separation" between

using

Quoted 1 line

the sync_scale and the dec_rate registers. The way things were

being done,

Quoted 1 line

we could easily get into a situation where the part could be running

with

Quoted 3 lines

an internal rate way lower than the optimal minimum.

For the adis16475 drivers, things were not really wrong. They were

just

Quoted 1 line

not optimal as we were forcing users to specify the IMU scaled

internal

Quoted 15 lines

rate once in the devicetree. Calculating things at runtime gives much more flexibility to choose the output rate.

Nuno Sá (4):
iio: adis: add helpers for locking
iio: adis16480: fix pps mode sampling frequency math
iio: adis16475: improve sync scale mode handling
dt-bindings: adis16475: remove property

 .../bindings/iio/imu/adi,adis16475.yaml       |   9 --
 drivers/iio/imu/adis16475.c                   | 110 ++++++++++++----
 drivers/iio/imu/adis16480.c                   | 120 +++++++++++++-----
 include/linux/iio/imu/adis.h                  |  10 ++
 4 files changed, 178 insertions(+), 71 deletions(-)
author maintainer
#14 lore raw
Quoted 122 lines

-----Original Message-----
From: Jonathan Cameron <[email protected]>
Sent: Sunday, January 31, 2021 12:36 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Rob Herring <[email protected]>; Peter Meerwald-Stadler <[email protected]>; Lars-Peter Clausen <[email protected]>; Hennerich, Michael <[email protected]>; Ardelean, Alexandru <[email protected]>
Subject: Re: [PATCH 0/4] Fix/Improve sync clock mode handling

Quoted 12 lines · Nuno
Quoted 12 lines

-----Original Message-----
From: Jonathan Cameron <[email protected]>
Sent: Sunday, January 24, 2021 3:21 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Rob Herring <[email protected]>; Peter Meerwald-Stadler <[email protected]>; Lars-Peter Clausen <[email protected]>; Hennerich, Michael <[email protected]>; Ardelean, Alexandru <[email protected]>
Subject: Re: [PATCH 0/4] Fix/Improve sync clock mode handling

Quoted 8 lines
Quoted 8 lines
Quoted 2 lines · On Thu, 21 Jan 2021 12:49:50 +0100 Nuno Sá <[email protected]> wrote:

The first patch in this series is just a simple helper to lock/unlock the device. Having these helpers make the code slightly neater

(IMHO).

Quoted 2 lines

The following patches introduces changes in the sampling

frequency

Quoted 1 line
Quoted 1 line
Quoted 1 line

calculation when sync scale/pps modes are used. First, it's

important

Quoted 1 line
Quoted 1 line
Quoted 1 line

to understand the purpose of this mode and how it should be

used.

Quoted 5 lines
Quoted 5 lines

Let's

Quoted 1 line

say our part has an internal rate of 4250 (e.g adis1649x family) and

the

Quoted 2 lines

user wants an output rate of 200SPS. Obviously, we can't use this sampling rate and divide back down to get 200 SPS with

decimation

Quoted 2 lines
Quoted 2 lines

on.

Quoted 1 line

Hence, we can use this mode to give an input clock of 1HZ, scale it

to

Quoted 1 line
Quoted 1 line
Quoted 1 line

something like 4200 or 4000 SPS and then use the decimation

filter to

Quoted 2 lines
Quoted 2 lines

get

Quoted 1 line

the exact desired 200SPS. There are also some limits that should

be

Quoted 11 lines
Quoted 11 lines
Quoted 11 lines

taken into account when scaling:

* For the devices in the adis16475 driver:
- Input sync frequency range is 1 to 128 Hz
- Native sample rate: 2 kSPS. Optimal range: 1900-2100 sps

* For the adis1649x family (adis16480 driver):
- Input sync frequency range is 1 to 128 Hz
- Native sample rate: 4.25 kSPS. Optimal range: 4000-4250 sps

I'm not 100% convinced on how to handle the optimal minimum.

For

Quoted 2 lines
Quoted 2 lines

now,

Quoted 1 line

I'm just throwing a warning saying we might get into trouble if we

get

Quoted 2 lines
Quoted 2 lines

a

Quoted 1 line

value lower than that. I was also tempted to just return -EINVAL

or

Quoted 1 line
Quoted 1 line
Quoted 1 line

clamp the value. However, I know that there are ADI customers

that

Quoted 1 line
Quoted 1 line
Quoted 1 line

(for some reason) are using a sampling rate lower than the

minimum

Quoted 5 lines
Quoted 5 lines
Quoted 1 line

advised.

So the opening question I'd have here is how critical is the actual
userspace sampling rate to your users? Often they don't mind
getting a little more data than they asked for (say 200.5Hz when

asking

Quoted 4 lines
Quoted 2 lines

for 200) and can always read back the attribute after writing it to discover this has happened.

Well, honestly I'm not really sure here. I can just say (from the info I

got internally) that some

Quoted 1 line

users are really using these parts with a data rate lower than the

advised. However, I'd say

Quoted 1 line

that this would depend on the use case. For some critical cases, I

would expect that users really

Quoted 1 line

want to have an exact sample rate. Though I'd argue that in those

cases, they should know what

Quoted 1 line

they are doing and provide an output rate that fits nicely (multiple of

both the input clock and IMU

Quoted 1 line

internal sample rate). And as you said, they can always readback the

value to check if they are

Quoted 6 lines

getting something that is not really what they expect...

Quoted 2 lines

As such, once you've discovered that value doesn't have an exact match, perhaps tweak the output data rate until it fits nicely?

I did thought about this. The reason why I didn't went for it in this

first version is because of those

Quoted 1 line

who seems to really want to run the part at lower rates. Let's assume

we have an input clock of

Quoted 1 line

1HZ and someone writes an output rate of 3000SPS. The only way to

accomplish this is to set

Quoted 1 line

sync_scale at 3000 and let the IMU run at 3000SPS with decimation

off (DEC_RATE=0). If we are

Quoted 1 line

going to tweak the output rate to fit nicely, we would have to force it

to 4000SPS which is

Quoted 1 line

significantly different from the desired 3000SPS.

Good point. If someone wants to do that there isn't much we can do to make it work nicely. I'd argue they are wrong and move it to the nearest within the constraints, but that might be rather unexpected
for them...

Quoted 5 lines

I wonder if we do something ugly like have an extra control to say 'really do what I say even if it's horrible'.
That would mean we'd get what 'most' users expect (I hope) in that it's within the documented range, but provide the control to those who want to do something horrible.. Not nice, what do you think?

You mean like a driver parameter? Not sure a runtime control would make much sense (either you want this or not). Yeah, it is definitely not pretty but I seems to be the only way to make everyone 'happy'.

Quoted 8 lines
Quoted 7 lines
Quoted 5 lines

A bit of quick investigation suggests (by my wife who happened to be sat across the room) suggests that you have a hideous set of local minima so your best bet is to brute force search (not that bad and we don't expect to change this a lot!)

Hmm, not sure what do you have in mind here :)?

Quoted 7 lines

You have two controllable parameters both of which are integers. As such
there isn't a nice easy 'right' answer for what combination to use. For example, if we have a case where there is no right answer, you will have to search for every possible multiplier, find the best divisor and check how far that is above the desired frequency. Of those find the smallest one (best option given constraints).

Hmm, I need to give it a thought and see what I can come up to v2. We continue from there.

But this opens one question... Do we want to tweak the output rate to fit
nicely only for 'if (imu_rate) < 4000' or should we also do it in the other cases? By other cases I mean 'if (lcm(output_rate, input_ckl) > max_imu_rate)' and in the generic case where we don't have external clock and the IMU runs
with it's internal rate (pretty much all the time the value does not fit nicely)? Note that DEC_RATE is an integer parameter and for things to fit nicely, the
rate given by the user should be a multiple of the IMU sampling rate. I'm bringing this up because if we are going into this much trouble to tweak the user rate to fit nicely and avoid 'possible' undersampling issues, we might do the same for the other cases... Otherwise, to avoid the oversampling case we could just force the IMU sample rate to the maximum multiple of the input clock lower than max_rate and calculate DEC_RATE with 'DIV_ROUND_CLOSEST()' which is what we are
already doing for the generic case. Naturally with this, the user won't get exactly what he might expect as DEC_RATE is an integer (but again, that is how things are now anyways)... We would still need the extra control for those who really want to stick to lower IMU rates.

- Nuno Sá

Quoted 40 lines

Jonathan

Quoted 5 lines

- Nuno Sá

Quoted 2 lines
Quoted 2 lines

That said, the patch for the adis16480 driver is a fix as this mode

was

Quoted 1 line
Quoted 1 line
Quoted 1 line

being wrongly handled. There should not be a "separation"

between

Quoted 4 lines
Quoted 4 lines

using

Quoted 1 line

the sync_scale and the dec_rate registers. The way things were

being done,

Quoted 1 line

we could easily get into a situation where the part could be

running

Quoted 4 lines
Quoted 4 lines

with

Quoted 3 lines

an internal rate way lower than the optimal minimum.

For the adis16475 drivers, things were not really wrong. They

were

Quoted 4 lines
Quoted 4 lines

just

Quoted 1 line

not optimal as we were forcing users to specify the IMU scaled

internal

Quoted 1 line

rate once in the devicetree. Calculating things at runtime gives

much

Quoted 15 lines
Quoted 14 lines
Quoted 14 lines

more flexibility to choose the output rate.

Nuno Sá (4):
iio: adis: add helpers for locking
iio: adis16480: fix pps mode sampling frequency math
iio: adis16475: improve sync scale mode handling
dt-bindings: adis16475: remove property

 .../bindings/iio/imu/adi,adis16475.yaml       |   9 --
 drivers/iio/imu/adis16475.c                   | 110 ++++++++++++----
 drivers/iio/imu/adis16480.c                   | 120 +++++++++++++-----
 include/linux/iio/imu/adis.h                  |  10 ++
 4 files changed, 178 insertions(+), 71 deletions(-)
maintainer
#15 lore raw
Quoted 126 lines · Nuno
Quoted 120 lines

-----Original Message-----
From: Jonathan Cameron <[email protected]>
Sent: Sunday, January 31, 2021 12:36 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Rob Herring <[email protected]>; Peter Meerwald-Stadler <[email protected]>; Lars-Peter Clausen <[email protected]>; Hennerich, Michael <[email protected]>; Ardelean, Alexandru <[email protected]>
Subject: Re: [PATCH 0/4] Fix/Improve sync clock mode handling

Quoted 12 lines · Nuno
Quoted 12 lines

-----Original Message-----
From: Jonathan Cameron <[email protected]>
Sent: Sunday, January 24, 2021 3:21 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Rob Herring <[email protected]>; Peter Meerwald-Stadler <[email protected]>; Lars-Peter Clausen <[email protected]>; Hennerich, Michael <[email protected]>; Ardelean, Alexandru <[email protected]>
Subject: Re: [PATCH 0/4] Fix/Improve sync clock mode handling

Quoted 8 lines
Quoted 8 lines
Quoted 2 lines · On Thu, 21 Jan 2021 12:49:50 +0100 Nuno Sá <[email protected]> wrote:

The first patch in this series is just a simple helper to lock/unlock the device. Having these helpers make the code slightly neater

(IMHO).

Quoted 2 lines

The following patches introduces changes in the sampling

frequency

Quoted 1 line
Quoted 1 line
Quoted 1 line

calculation when sync scale/pps modes are used. First, it's

important

Quoted 1 line
Quoted 1 line
Quoted 1 line

to understand the purpose of this mode and how it should be

used.

Quoted 5 lines
Quoted 5 lines

Let's

Quoted 1 line

say our part has an internal rate of 4250 (e.g adis1649x family) and

the

Quoted 2 lines

user wants an output rate of 200SPS. Obviously, we can't use this sampling rate and divide back down to get 200 SPS with

decimation

Quoted 2 lines
Quoted 2 lines

on.

Quoted 1 line

Hence, we can use this mode to give an input clock of 1HZ, scale it

to

Quoted 1 line
Quoted 1 line
Quoted 1 line

something like 4200 or 4000 SPS and then use the decimation

filter to

Quoted 2 lines
Quoted 2 lines

get

Quoted 1 line

the exact desired 200SPS. There are also some limits that should

be

Quoted 11 lines
Quoted 11 lines
Quoted 11 lines

taken into account when scaling:

* For the devices in the adis16475 driver:
- Input sync frequency range is 1 to 128 Hz
- Native sample rate: 2 kSPS. Optimal range: 1900-2100 sps

* For the adis1649x family (adis16480 driver):
- Input sync frequency range is 1 to 128 Hz
- Native sample rate: 4.25 kSPS. Optimal range: 4000-4250 sps

I'm not 100% convinced on how to handle the optimal minimum.

For

Quoted 2 lines
Quoted 2 lines

now,

Quoted 1 line

I'm just throwing a warning saying we might get into trouble if we

get

Quoted 2 lines
Quoted 2 lines

a

Quoted 1 line

value lower than that. I was also tempted to just return -EINVAL

or

Quoted 1 line
Quoted 1 line
Quoted 1 line

clamp the value. However, I know that there are ADI customers

that

Quoted 1 line
Quoted 1 line
Quoted 1 line

(for some reason) are using a sampling rate lower than the

minimum

Quoted 5 lines
Quoted 5 lines
Quoted 1 line

advised.

So the opening question I'd have here is how critical is the actual
userspace sampling rate to your users? Often they don't mind
getting a little more data than they asked for (say 200.5Hz when

asking

Quoted 4 lines
Quoted 2 lines

for 200) and can always read back the attribute after writing it to discover this has happened.

Well, honestly I'm not really sure here. I can just say (from the info I

got internally) that some

Quoted 1 line

users are really using these parts with a data rate lower than the

advised. However, I'd say

Quoted 1 line

that this would depend on the use case. For some critical cases, I

would expect that users really

Quoted 1 line

want to have an exact sample rate. Though I'd argue that in those

cases, they should know what

Quoted 1 line

they are doing and provide an output rate that fits nicely (multiple of

both the input clock and IMU

Quoted 1 line

internal sample rate). And as you said, they can always readback the

value to check if they are

Quoted 6 lines

getting something that is not really what they expect...

Quoted 2 lines

As such, once you've discovered that value doesn't have an exact match, perhaps tweak the output data rate until it fits nicely?

I did thought about this. The reason why I didn't went for it in this

first version is because of those

Quoted 1 line

who seems to really want to run the part at lower rates. Let's assume

we have an input clock of

Quoted 1 line

1HZ and someone writes an output rate of 3000SPS. The only way to

accomplish this is to set

Quoted 1 line

sync_scale at 3000 and let the IMU run at 3000SPS with decimation

off (DEC_RATE=0). If we are

Quoted 1 line

going to tweak the output rate to fit nicely, we would have to force it

to 4000SPS which is

Quoted 1 line

significantly different from the desired 3000SPS.

Good point. If someone wants to do that there isn't much we can do to make it work nicely. I'd argue they are wrong and move it to the nearest within the constraints, but that might be rather unexpected
for them...

Quoted 5 lines

I wonder if we do something ugly like have an extra control to say 'really do what I say even if it's horrible'.
That would mean we'd get what 'most' users expect (I hope) in that it's within the documented range, but provide the control to those who want to do something horrible.. Not nice, what do you think?

Quoted 3 lines

You mean like a driver parameter? Not sure a runtime control would make much sense (either you want this or not). Yeah, it is definitely not pretty but I seems to be the only way to make everyone 'happy'.

Agreed. Would make more sense as a driver parameter than anything else.

Quoted 17 lines
Quoted 9 lines
Quoted 8 lines
Quoted 6 lines

A bit of quick investigation suggests (by my wife who happened to be sat across the room) suggests that you have a hideous set of local minima so your best bet is to brute force search (not that bad and we don't expect to change this a lot!)

Hmm, not sure what do you have in mind here :)?

Quoted 7 lines

You have two controllable parameters both of which are integers. As such
there isn't a nice easy 'right' answer for what combination to use. For example, if we have a case where there is no right answer, you will have to search for every possible multiplier, find the best divisor and check how far that is above the desired frequency. Of those find the smallest one (best option given constraints).

Quoted 6 lines

Hmm, I need to give it a thought and see what I can come up to v2. We continue from there.

But this opens one question... Do we want to tweak the output rate to fit nicely only for 'if (imu_rate) < 4000' or should we also do it in the other cases? By other cases I mean 'if (lcm(output_rate, input_ckl) > max_imu_rate)'

For that case, there will still be a 'best' value I think that gets us close to output rate (from above) as possible.

Quoted 2 lines

and in the generic case where we don't have external clock and the IMU runs with it's internal rate (pretty much all the time the value does not fit nicely)?

If it's running with internal rate then we will always have to do a best aproximation from above. Often people care about 'at least this rate and not "too much" more' where too much is very fuzzy as it's more a question of the system being able to cope with the extra load than any absolute rule.

If we are already doing closest as you say below, then it's probably close enough that no one has ever moaned about it and we should stick to that.

Quoted 10 lines

Note that DEC_RATE is an integer parameter and for things to fit nicely, the
rate given by the user should be a multiple of the IMU sampling rate. I'm bringing this up because if we are going into this much trouble to tweak the user rate to fit nicely and avoid 'possible' undersampling issues, we might do the same for the other cases... Otherwise, to avoid the oversampling case we could just force the IMU sample rate to the maximum multiple of the input clock lower than max_rate and calculate DEC_RATE with 'DIV_ROUND_CLOSEST()' which is what we are
already doing for the generic case. Naturally with this, the user won't get exactly what he might expect as DEC_RATE is an integer (but again, that is how things are now anyways)... We would still need the extra control for those who really want to stick to lower IMU rates.

Agreed, it makes sense to do the same whether it's an external clock or internal clock.

Jonathan

Quoted 44 lines

- Nuno Sá

Quoted 40 lines

Jonathan

Quoted 5 lines

- Nuno Sá

Quoted 2 lines
Quoted 2 lines

That said, the patch for the adis16480 driver is a fix as this mode

was

Quoted 1 line
Quoted 1 line
Quoted 1 line

being wrongly handled. There should not be a "separation"

between

Quoted 4 lines
Quoted 4 lines

using

Quoted 1 line

the sync_scale and the dec_rate registers. The way things were

being done,

Quoted 1 line

we could easily get into a situation where the part could be

running

Quoted 4 lines
Quoted 4 lines

with

Quoted 3 lines

an internal rate way lower than the optimal minimum.

For the adis16475 drivers, things were not really wrong. They

were

Quoted 4 lines
Quoted 4 lines

just

Quoted 1 line

not optimal as we were forcing users to specify the IMU scaled

internal

Quoted 1 line

rate once in the devicetree. Calculating things at runtime gives

much

Quoted 15 lines
Quoted 14 lines
Quoted 14 lines

more flexibility to choose the output rate.

Nuno Sá (4):
iio: adis: add helpers for locking
iio: adis16480: fix pps mode sampling frequency math
iio: adis16475: improve sync scale mode handling
dt-bindings: adis16475: remove property

 .../bindings/iio/imu/adi,adis16475.yaml       |   9 --
 drivers/iio/imu/adis16475.c                   | 110 ++++++++++++----
 drivers/iio/imu/adis16480.c                   | 120 +++++++++++++-----
 include/linux/iio/imu/adis.h                  |  10 ++
 4 files changed, 178 insertions(+), 71 deletions(-)
author maintainer
#16 lore raw
In reply to Jonathan Cameron
Quoted 52 lines

-----Original Message-----
From: Jonathan Cameron <[email protected]>
Sent: Sunday, January 24, 2021 3:21 PM
To: Sa, Nuno <[email protected]>
Cc: [email protected]; [email protected]; Rob Herring <[email protected]>; Peter Meerwald-Stadler <[email protected]>; Lars-Peter Clausen <[email protected]>; Hennerich, Michael <[email protected]>; Ardelean, Alexandru <[email protected]>
Subject: Re: [PATCH 0/4] Fix/Improve sync clock mode handling

Quoted 2 lines · On Thu, 21 Jan 2021 12:49:50 +0100 Nuno Sá <[email protected]> wrote:

The first patch in this series is just a simple helper to lock/unlock the device. Having these helpers make the code slightly neater

(IMHO).

Quoted 4 lines

The following patches introduces changes in the sampling frequency calculation when sync scale/pps modes are used. First, it's important to understand the purpose of this mode and how it should be used.

Let's

Quoted 1 line

say our part has an internal rate of 4250 (e.g adis1649x family) and

the

Quoted 2 lines

user wants an output rate of 200SPS. Obviously, we can't use this sampling rate and divide back down to get 200 SPS with decimation

on.

Quoted 2 lines

Hence, we can use this mode to give an input clock of 1HZ, scale it to something like 4200 or 4000 SPS and then use the decimation filter to

get

Quoted 7 lines

the exact desired 200SPS. There are also some limits that should be taken into account when scaling:

* For the devices in the adis16475 driver:
- Input sync frequency range is 1 to 128 Hz
- Native sample rate: 2 kSPS. Optimal range: 1900-2100 sps

Quoted 5 lines

* For the adis1649x family (adis16480 driver):
- Input sync frequency range is 1 to 128 Hz
- Native sample rate: 4.25 kSPS. Optimal range: 4000-4250 sps

I'm not 100% convinced on how to handle the optimal minimum. For

now,

Quoted 1 line

I'm just throwing a warning saying we might get into trouble if we get

a

Quoted 4 lines

value lower than that. I was also tempted to just return -EINVAL or clamp the value. However, I know that there are ADI customers that (for some reason) are using a sampling rate lower than the minimum advised.

Quoted 6 lines

So the opening question I'd have here is how critical is the actual
userspace sampling rate to your users? Often they don't mind
getting a little more data than they asked for (say 200.5Hz when asking for 200) and can always read back the attribute after writing it to discover this has happened.

Well, honestly I'm not really sure here. I can just say (from the info I got internally) that some users are really using these parts with a data rate lower than the advised. However, I'd say that this would depend on the use case. For some critical cases, I would expect that users really want to have an exact sample rate. Though I'd argue that in those cases, they should know what they are doing and provide an output rate that fits nicely (multiple of both the input clock and IMU internal sample rate). And as you said, they can always readback the value to check if they are getting something that is not really what they expect...

Quoted 2 lines

As such, once you've discovered that value doesn't have an exact match, perhaps tweak the output data rate until it fits nicely?

I did thought about this. The reason why I didn't went for it in this first version is because of those who seems to really want to run the part at lower rates. Let's assume we have an input clock of 1HZ and someone writes an output rate of 3000SPS. The only way to accomplish this is to set sync_scale at 3000 and let the IMU run at 3000SPS with decimation off (DEC_RATE=0). If we are going to tweak the output rate to fit nicely, we would have to force it to 4000SPS which is significantly different from the desired 3000SPS.

Quoted 4 lines

A bit of quick investigation suggests (by my wife who happened to be sat across the room) suggests that you have a hideous set of local minima so your best bet is to brute force search (not that bad and we don't expect to change this a lot!)

Hmm, not sure what do you have in mind here :)?

- Nuno Sa

Quoted 30 lines
Quoted 4 lines

That said, the patch for the adis16480 driver is a fix as this mode was being wrongly handled. There should not be a "separation" between

using

Quoted 1 line

the sync_scale and the dec_rate registers. The way things were

being done,

Quoted 1 line

we could easily get into a situation where the part could be running

with

Quoted 3 lines

an internal rate way lower than the optimal minimum.

For the adis16475 drivers, things were not really wrong. They were

just

Quoted 1 line

not optimal as we were forcing users to specify the IMU scaled

internal

Quoted 15 lines

rate once in the devicetree. Calculating things at runtime gives much more flexibility to choose the output rate.

Nuno Sá (4):
iio: adis: add helpers for locking
iio: adis16480: fix pps mode sampling frequency math
iio: adis16475: improve sync scale mode handling
dt-bindings: adis16475: remove property

 .../bindings/iio/imu/adi,adis16475.yaml       |   9 --
 drivers/iio/imu/adis16475.c                   | 110 ++++++++++++----
 drivers/iio/imu/adis16480.c                   | 120 +++++++++++++-----
 include/linux/iio/imu/adis.h                  |  10 ++
 4 files changed, 178 insertions(+), 71 deletions(-)