Hi All,

I'm confusing at the VLAN validation mechanism of RoCEv2.

Assuming that we have two nodes with an HCA that supports RoCE v2. And we add a VLAN (id = 1) on each nodes, but they are of different network segments. The IP and VLAN configuration are as follows:

NODE_A NODE_B

+--------+---------------+------+          +--------+---------------+------+
| device |     IP        | VLAN |          | device |     IP        | VLAN |
+--------+---------------+------+          +--------+---------------+------+
| eth0   | 192.168.97.1  |   0  |     /----| eth0   | 192.168.100.2 |   0  |
+--------+---------------+------+    /     +--------+---------------+------+
| eth0.1 | 192.168.100.3 |   1  |---/      | eth0.1 | 192.168.98.2  |   1  |
+--------+---------------+------+          +--------+---------------+------+

Now I try to ping eth0 on NODE_B from eth0.1 on NODE_A, of cource it fails becauce these devices are using different VLAN ID.

Then I do some tests on RoCE, the first one is a simple RC send test:

NODE_A: ib_send_bw -d mlx5_0 -x 5 (the sgid 5 belongs to eth0.1)
NODE_B: ib_send_bw -d mlx5_0 -x 3 <server ip> (the sgid 3 belongs to eth0)

The result is as expected, the RoCEv2 packet with unmatched VLAN ID was dropped. I think the reason is that for RC service, the VLAN information of a QP is recorded in QPC, and the HCA can check it when receiving a packet.

But when I run a simple UD send test:

NODE_A: ib_send_bw -d mlx5_0 -x 5 -c UD (the sgid 5 belongs to eth0.1)
NODE_B: ib_send_bw -d mlx5_0 -x 3 -c UD <server ip> (the sgid 3 belongs to eth0)

The test ends without error successfully. So the question is, RoCEv2 is based on Ethernet, shouldn't a RoCEv2 node check the VLAN ID of every incoming packets?

UD is connectionless-oriented, an UD QP won't record VLAN info in it's QPC, so how to achieve the checking mechanism? Or a UD QP should just ignore the unmatched VLAN ID?

I didn't find any info from the IB specification, I'd appreciate it if someone could help explain it.

Thanks
Weihang

maintainer
#1 lore raw
Quoted 3 lines · liweihang

UD is connectionless-oriented, an UD QP won't record VLAN info in it's QPC, so how to achieve the checking mechanism? Or a UD QP should just ignore the unmatched VLAN ID?

Right, UD QPs recieve all packets for the entire device that match the UD QPN

They indirectly report the incoming gid table index they were matched with in the completion and the first 40 bytes

If an app only wants to look at certain gid table entries then it is up to the app to filter

Jason

author
#2 lore raw
Quoted 9 lines · Jason Gunthorpe
Quoted 3 lines · liweihang

UD is connectionless-oriented, an UD QP won't record VLAN info in it's QPC, so how to achieve the checking mechanism? Or a UD QP should just ignore the unmatched VLAN ID?

Right, UD QPs recieve all packets for the entire device that match the UD QPN

Quoted 8 lines

They indirectly report the incoming gid table index they were matched with in the completion and the first 40 bytes

If an app only wants to look at certain gid table entries then it is up to the app to filter

Jason

Thank you, Jason. It's really helpful.

Weihang