fcntl: make F_GETOWN(EX) return 0 on dead owner task
Subsystems (2)
PATCH 1/1 fcntl: make F_GETOWN(EX) return 0 on dead owner task
Currently there is no way to differentiate the file with alive owner from the file with dead owner but pid of the owner reused. That's why CRIU can't actually know if it needs to restore file owner or not, because if it restores owner but actual owner was dead, this can introduce unexpected signals to the "false"-owner (which reused the pid).
Let's change the api, so that F_GETOWN(EX) returns 0 in case actual owner is dead already.
--- fs/fcntl.c | 19 +++++++++++++------ 1 file changed, 13 insertions(+), 6 deletions(-)
fs/fcntl.c +13 -6
@@ -148,11 +148,15 @@ void f_delown(struct file *filp)pid_t f_getown (struct file *filp) { -pid_t pid; +pid_t pid =0 ;read_lock (&filp->f_owner.lock); - pid =pid_vnr (filp->f_owner.pid); -if (filp->f_owner.pid_type ==PIDTYPE_PGID ) - pid = -pid; +rcu_read_lock (); +if (pid_task (filp->f_owner.pid, filp->f_owner.pid_type)) { + pid =pid_vnr (filp->f_owner.pid); +if (filp->f_owner.pid_type ==PIDTYPE_PGID ) + pid = -pid; + } +rcu_read_unlock ();read_unlock (&filp->f_owner.lock);return pid; }
@@ -200,11 +204,14 @@ static int f_setown_ex(struct file *filp, unsigned long arg)static int f_getown_ex (struct file *filp,unsigned long arg) {struct f_owner_ex __user *owner_p = (void __user *)arg; -struct f_owner_ex owner; +struct f_owner_ex owner = {};int ret =0 ;read_lock (&filp->f_owner.lock); - owner.pid =pid_vnr (filp->f_owner.pid); +rcu_read_lock (); +if (pid_task (filp->f_owner.pid, filp->f_owner.pid_type)) + owner.pid =pid_vnr (filp->f_owner.pid); +rcu_read_unlock ();switch (filp->f_owner.pid_type) {case PIDTYPE_PID : owner.type =F_OWNER_TID ;
Signature · 1 line
2.26.2
Quoted 6 lines · Pavel Tikhomirov
Currently there is no way to differentiate the file with alive owner from the file with dead owner but pid of the owner reused. That's why CRIU can't actually know if it needs to restore file owner or not, because if it restores owner but actual owner was dead, this can introduce unexpected signals to the "false"-owner (which reused the pid).
Hi! Thanks for the patch. You know I manage to forget the fowner internals. Could you please enlighten me -- when owner is set with some pid we do
f_setown_ex
__f_setown
f_modown
filp->f_owner.pid = get_pid(pid);Thus pid get refcount incremented. Then the owner exits but refcounter should be still up and running and pid should not be reused, no? Or I miss something obvious?
The patch itself looks ok on a first glance.
Quoted 11 lines · Cyrill Gorcunov
Quoted 6 lines · Pavel Tikhomirov
Currently there is no way to differentiate the file with alive owner from the file with dead owner but pid of the owner reused. That's why CRIU can't actually know if it needs to restore file owner or not, because if it restores owner but actual owner was dead, this can introduce unexpected signals to the "false"-owner (which reused the pid).
Hi! Thanks for the patch. You know I manage to forget the fowner internals. Could you please enlighten me -- when owner is set with some pid we do
Quoted 6 lines
f_setown_ex
__f_setownf_modown filp->f_owner.pid = get_pid(pid);Thus pid get refcount incremented.
Hi, and yes you are right about refcount is held.
Then the owner exits but refcounter
Quoted 2 lines
should be still up and running and pid should not be reused, no? Or I miss something obvious?
AFAICS if pid is held only by 1) fowner refcount and by 2) single process (without threads, group and session for simplicity), on process exit we go through:
do_exit
exit_notify
release_task
__exit_signal
__unhash_process
detach_pid
__change_pid
free_pid
idr_remove
So pid is removed from idr, and after that alloc_pid can reuse pid numbers even if old pid structure is still alive and is still held by fowner.
Also I've added criu-zdtm test which reproduces the problem:
Hope this answers your question, Thanks!
Quoted 3 lines
The patch itself looks ok on a first glance.
Signature · 2 lines
Best regards, Tikhomirov Pavel Software Developer, Virtuozzo.
Quoted 17 lines · Pavel Tikhomirov
AFAICS if pid is held only by 1) fowner refcount and by 2) single process (without threads, group and session for simplicity), on process exit we go through:
do_exit
exit_notify
release_task
__exit_signal
__unhash_process
detach_pid
__change_pid
free_pid
idr_removeSo pid is removed from idr, and after that
alloc_pidcan reuse pid numbers even if old pid structure is still alive and is still held by fowner.
...
Quoted 1 line
Hope this answers your question, Thanks!
Yeah, indeed, thanks! So the change is sane still I'm a bit worried about backward compatibility, gimme some time I'll try to refresh my memory first, in a couple of days or weekend (though here are a number of experienced developers CC'ed maybe they reply even faster).
Jeff Layton
maintainerQuoted 18 lines · Cyrill Gorcunov
Quoted 15 lines · Pavel Tikhomirov
AFAICS if pid is held only by 1) fowner refcount and by 2) single process (without threads, group and session for simplicity), on process exit we go through:
do_exit
exit_notify
release_task
__exit_signal
__unhash_process
detach_pid
__change_pid
free_pid
idr_removeQuoted 2 lines
So pid is removed from idr, and after that
alloc_pidcan reuse pid numbers even if old pid structure is still alive and is still held by fowner.
Quoted 8 lines
...
Quoted 1 line
Hope this answers your question, Thanks!
Yeah, indeed, thanks! So the change is sane still I'm a bit worried about backward compatibility, gimme some time I'll try to refresh my memory first, in a couple of days or weekend (though here are a number of experienced developers CC'ed maybe they reply even faster).
I always find it helpful to refer to the POSIX spec [1] for this sort of thing. In this case, it says:
F_GETOWN
If fildes refers to a socket, get the process ID or process group ID
specified to receive SIGURG signals when out-of-band data is available. Positive values shall indicate a process ID; negative values, other than -1, shall indicate a process group ID; the value zero shall indicate that no SIGURG signals are to be sent. If fildes does not refer to a socket, the results are unspecified.
In the event that the PID is reused, the kernel won't send signals to the replacement task, correct? Assuming that's the case, then this patch looks fine to me too. I'll plan to pick it for linux-next later today, and we can hopefully get this into v5.12.
[1]: https://pubs.opengroup.org/onlinepubs/9699919799/functions/fcntl.html#tag_16_122
Signature · 1 line
Jeff Layton <[email protected]>
Quoted 39 lines · Jeff Layton
Quoted 18 lines · Cyrill Gorcunov
Quoted 15 lines · Pavel Tikhomirov
AFAICS if pid is held only by 1) fowner refcount and by 2) single process (without threads, group and session for simplicity), on process exit we go through:
do_exit
exit_notify
release_task
__exit_signal
__unhash_process
detach_pid
__change_pid
free_pid
idr_removeQuoted 2 lines
So pid is removed from idr, and after that
alloc_pidcan reuse pid numbers even if old pid structure is still alive and is still held by fowner.Quoted 8 lines
...
Quoted 1 line
Hope this answers your question, Thanks!
Yeah, indeed, thanks! So the change is sane still I'm a bit worried about backward compatibility, gimme some time I'll try to refresh my memory first, in a couple of days or weekend (though here are a number of experienced developers CC'ed maybe they reply even faster).
I always find it helpful to refer to the POSIX spec [1] for this sort of thing. In this case, it says:
F_GETOWN
If fildes refers to a socket, get the process ID or process group ID
specified to receive SIGURG signals when out-of-band data is available. Positive values shall indicate a process ID; negative values, other than -1, shall indicate a process group ID; the value zero shall indicate that no SIGURG signals are to be sent. If fildes does not refer to a socket, the results are unspecified.
Quoted 2 lines
In the event that the PID is reused, the kernel won't send signals to the replacement task, correct?
Correct. Looks like only places to send signal to owner are send_sigio() and send_sigurg() (at least nobody else dereferences fown->pid_type). And in both places we lookup for task to send signal to with pid_task() or do_each_pid_task() (similar to what I do in patch) and will not find any task if pid was reused. Thus no signal would be sent.
Quoted 6 lines
Assuming that's the case, then this patch
looks fine to me too. I'll plan to pick it for linux-next later today, and we can hopefully get this into v5.12.[1]: https://pubs.opengroup.org/onlinepubs/9699919799/functions/fcntl.html#tag_16_122
Thanks for finding it!
Signature · 2 lines
Best regards, Tikhomirov Pavel Software Developer, Virtuozzo.
Jeff Layton
maintainerQuoted 41 lines · Pavel Tikhomirov
Quoted 39 lines · Jeff Layton
Quoted 18 lines · Cyrill Gorcunov
Quoted 15 lines · Pavel Tikhomirov
AFAICS if pid is held only by 1) fowner refcount and by 2) single process (without threads, group and session for simplicity), on process exit we go through:
do_exit
exit_notify
release_task
__exit_signal
__unhash_process
detach_pid
__change_pid
free_pid
idr_removeQuoted 2 lines
So pid is removed from idr, and after that
alloc_pidcan reuse pid numbers even if old pid structure is still alive and is still held by fowner.Quoted 8 lines
...
Quoted 1 line
Hope this answers your question, Thanks!
Yeah, indeed, thanks! So the change is sane still I'm a bit worried about backward compatibility, gimme some time I'll try to refresh my memory first, in a couple of days or weekend (though here are a number of experienced developers CC'ed maybe they reply even faster).
I always find it helpful to refer to the POSIX spec [1] for this sort of thing. In this case, it says:
F_GETOWN
If fildes refers to a socket, get the process ID or process group ID specified to receive SIGURG signals when out-of-band data is available. Positive values shall indicate a process ID; negative values, other than -1, shall indicate a process group ID; the value zero shall indicate that no SIGURG signals are to be sent. If fildes does not refer to a socket, the results are unspecified.
Quoted 9 lines
Quoted 2 lines
In the event that the PID is reused, the kernel won't send signals to the replacement task, correct?
Correct. Looks like only places to send signal to owner are
send_sigio()andsend_sigurg()(at least nobody else dereferencesfown->pid_type). And in both places we lookup for task to send signal to withpid_task()ordo_each_pid_task()(similar to what I do in patch) and will not find any task if pid was reused. Thus no signal would be sent.
Thanks for confirming it. I queued it up for linux-next (with a small amendment to the changelog), and it should be there later today or tomorrow. It might not hurt to roll up a manpage patch too if you have the cycles. It'd be nice to spell out what a 0 return means there.
Quoted 9 lines
Quoted 6 lines
Assuming that's the case, then this patch
looks fine to me too. I'll plan to pick it for linux-next later today, and we can hopefully get this into v5.12.[1]: https://pubs.opengroup.org/onlinepubs/9699919799/functions/fcntl.html#tag_16_122
Thanks for finding it!
No problem. That site is worth bookmarking for this sort of thing... ;)
Signature · 1 line
Jeff Layton <[email protected]>
Quoted 10 lines · Pavel Tikhomirov
Currently there is no way to differentiate the file with alive owner from the file with dead owner but pid of the owner reused. That's why CRIU can't actually know if it needs to restore file owner or not, because if it restores owner but actual owner was dead, this can introduce unexpected signals to the "false"-owner (which reused the pid).
Let's change the api, so that
F_GETOWN(EX)returns 0 in case actual owner is dead already.
Quoted 8 lines
Cc Jeff Layton <[email protected]>Cc "J. Bruce Fields" <[email protected]>Cc Alexander Viro <[email protected]>Cc Cyrill Gorcunov <[email protected]>Cc Andrei Vagin <[email protected]>Signed-off-by Pavel Tikhomirov <[email protected]>
I can't imagine a scenario where we could break some backward compatibility with this change, so