station: move scan cancelation to __station_connect_network
PATCH v3 1/2 station: move scan cancelation to __station_connect_network
An earlier patch fixed a problem where a queued quick scan would be triggered and fail once already connected, resulting in a state transition from connected --> autoconnect_full. This fixed the Connect() path but this could also happen via autoconnect. Starting from a connected state, the sequence goes:
- DBus scan is triggered
- AP disconnects IWD
- State transition from disconnected --> autoconnect_quick
- Queue quick scan
- DBus scan results come in and used to autoconnect
- A connect work item is inserted ahead of all others, transition from autoconnect_quick --> connecting.
- Connect completes, transition from connecting --> connected
- Quick scan can finally get triggered, which the kernel fails to do since IWD is connected, transition from connected --> autoconnect_full.
This can be fixed by checking for a pending quick scan in the autoconnect path.
--- src/station.c | 7 +++++++ 1 file changed, 7 insertions(+)
v3:
* Moved check into the autoconnect path rather than __station_connect_network
src/station.c +7 -0
@@ -196,6 +196,13 @@ static void station_autoconnect_next(struct station *station)if (!r) {station_enter_state (station,STATION_STATE_CONNECTING ); + +if (station->quick_scan_id) { +scan_cancel (netdev_get_wdev_id (station->netdev), + station->quick_scan_id); + station->quick_scan_id =0 ; + } +return ; } }
Signature · 1 line
2.26.2
PATCH v3 2/2 auto-t: fix wait_for_object_condition to work with any object
After recent changes fixing wait_for_object_condition it was accidentally made to only work with classes, not other types of objects. Instead create a minimal class to hold _wait_timed_out so it doesnt rely on 'obj' holding the boolean.
--- autotests/util/iwd.py | 15 +++++++++------ 1 file changed, 9 insertions(+), 6 deletions(-)
autotests/util/iwd.py +9 -6
@@ -1009,23 +1009,26 @@ class IWD(AsyncOpAbstract): @staticmethod def _wait_for_object_condition(obj, condition_str, max_wait = 50): - obj._wait_timed_out = False + class TimeoutData: + _wait_timed_out = False - def wait_timeout_cb(): - obj._wait_timed_out = True + data = TimeoutData() + + def wait_timeout_cb(data): + data._wait_timed_out = True return False try: - timeout = GLib.timeout_add_seconds(max_wait, wait_timeout_cb) + timeout = GLib.timeout_add_seconds(max_wait, wait_timeout_cb, data) context = ctx.mainloop.get_context() while not eval(condition_str): context.iteration(may_block=True) - if obj._wait_timed_out and ctx.args.gdb == None: + if data._wait_timed_out and ctx.args.gdb == None: raise TimeoutError('[' + condition_str + ']'\ ' condition was not met in '\ + str(max_wait) + ' sec') finally: - if not obj._wait_timed_out: + if not data._wait_timed_out: GLib.source_remove(timeout) def wait_for_object_condition(self, *args, **kwargs):
Signature · 1 line
2.26.2
Hi James,
Quoted 18 lines · James Prestwood
An earlier patch fixed a problem where a queued quick scan would be triggered and fail once already connected, resulting in a state transition from connected -->
autoconnect_full. This fixed theConnect()path but this could also happen via autoconnect. Starting from a connected state, the sequence goes:- DBus scan is triggered
- AP disconnects IWD
- State transition from disconnected -->autoconnect_quick
- Queue quick scan
- DBus scan results come in and used to autoconnect
- A connect work item is inserted ahead of all others, transitionfrom autoconnect_quick --> connecting. - Connect completes, transition from connecting --> connected - Quick scan can finally get triggered, which the kernel fails to do since IWD is connected, transition from connected --> autoconnect_full.
Quoted 5 lines
This can be fixed by checking for a pending quick scan in the autoconnect path.
--- src/station.c | 7 +++++++ 1 file changed, 7 insertions(+)
Both applied, thanks.
Regards,
-Denis