PATCH 1/1 platform/x86: pmc_atom: Match all Beckhoff Automation baytrail boards with critclk_systems DMI table

From: Steffen Dirkwinkel <[email protected]>

pmc_plt_clk* clocks are used for ethernet controllers so need to stay turned on. This adds the affected board family to critclk_systems DMI table so the clocks are marked as CLK_CRITICAL and not turned off.

This replaces the previosly listed boards with a match for the whole device family. There are new affected boards that would otherwise need to be listed. There are only few unaffected boards in the family and having the clocks turned on is not an issue on those.

Fixes 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
---
 drivers/platform/x86/pmc_atom.c | 28 ++--------------------------
 1 file changed, 2 insertions(+), 26 deletions(-)
drivers/platform/x86/pmc_atom.c +2 -26
index ca684ed760d1..a9d2a4b98e57 100644
@@ -393,34 +393,10 @@ static const struct dmi_system_id critclk_systems[] = {
 	},
 	{
 		/* pmc_plt_clk* - are used for ethernet controllers */
-		.ident = "Beckhoff CB3163",
+		.ident = "Beckhoff Baytrail",
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
-			DMI_MATCH(DMI_BOARD_NAME, "CB3163"),
-		},
-	},
-	{
-		/* pmc_plt_clk* - are used for ethernet controllers */
-		.ident = "Beckhoff CB4063",
-		.matches = {
-			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
-			DMI_MATCH(DMI_BOARD_NAME, "CB4063"),
-		},
-	},
-	{
-		/* pmc_plt_clk* - are used for ethernet controllers */
-		.ident = "Beckhoff CB6263",
-		.matches = {
-			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
-			DMI_MATCH(DMI_BOARD_NAME, "CB6263"),
-		},
-	},
-	{
-		/* pmc_plt_clk* - are used for ethernet controllers */
-		.ident = "Beckhoff CB6363",
-		.matches = {
-			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
-			DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
+			DMI_MATCH(DMI_PRODUCT_FAMILY, "CBxx63"),
 		},
 	},
 	{
Signature · 1 line
2.31.1
#1 lore raw
Quoted 8 lines · Steffen Dirkwinkel

From: Steffen Dirkwinkel <[email protected]>

pmc_plt_clk* clocks are used for ethernet controllers so need to stay turned on. This adds the affected board family to critclk_systems DMI table so the clocks are marked as CLK_CRITICAL and not turned off.

This replaces the previosly listed boards with a match for the whole

"...previously..."

Quoted 2 lines

device family. There are new affected boards that would otherwise need to be listed. There are only few unaffected boards in the family and

"...only a few..."

Quoted 1 line

having the clocks turned on is not an issue on those.

"...not an issue."

Quoted 2 lines
Fixes 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")

I'm afraid it's a bit too much. Is there any guarantee all the boards based on x86 will be Baytrail only?

Signature · 2 lines
With Best Regards,
Andy Shevchenko
#2 lore raw
Quoted 6 lines · Andy Shevchenko
Quoted 3 lines · Steffen Dirkwinkel

From: Steffen Dirkwinkel <[email protected]>

Quoted 7 lines
Quoted 5 lines

pmc_plt_clk* clocks are used for ethernet controllers so need to stay turned on. This adds the affected board family to critclk_systems DMI table so the clocks are marked as CLK_CRITICAL and not turned off.

This replaces the previosly listed boards with a match for the whole

"...previously..."

thanks

Quoted 5 lines
Quoted 3 lines

device family. There are new affected boards that would otherwise need to be listed. There are only few unaffected boards in the family and

"...only a few..."

will drop the phrase

Quoted 4 lines
Quoted 2 lines

having the clocks turned on is not an issue on those.

"...not an issue."

Not an issue for these industrial PCs as sleep is an unusual use case. Having no ethernet after boot/sleep is worse.

Quoted 7 lines
Quoted 3 lines
Fixes 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")

I'm afraid it's a bit too much. Is there any guarantee all the boards based on x86 will be Baytrail only?

Sorry, I guess I should make this clearer in the message. All boards with "CBxx63" are Baytrail.

Quoted 4 lines

--
With Best Regards,
Andy Shevchenko

Beckhoff Automation GmbH & Co. KG | Managing Director: Dipl. Phys. Hans Beckhoff Registered office: Verl, Germany | Register court: Guetersloh HRA 7075

#3 lore raw
Quoted 3 lines · linux-kernel-dev
Quoted 2 lines · Andy Shevchenko

On Mon, Apr 12, 2021 at 12:29 PM Steffen Dirkwinkel <[email protected]> wrote:

...

Quoted 5 lines
Quoted 3 lines

I'm afraid it's a bit too much. Is there any guarantee all the boards based on x86 will be Baytrail only?

Sorry, I guess I should make this clearer in the message. All boards with "CBxx63" are Baytrail.

Exactly! And this supports my idea that this shouldn't be done like in this patch.
Are you guaranteeing that *all x86-based* boards produced by your company will be Baytrail only?
Above tells that the answer is rather "no". So, I think we can't apply this patch in its current form.

Signature · 2 lines
With Best Regards,
Andy Shevchenko
#4 lore raw
Quoted 17 lines · Andy Shevchenko

CAUTION: External Email!!

Quoted 3 lines · linux-kernel-dev
Quoted 2 lines · Andy Shevchenko

On Mon, Apr 12, 2021 at 12:29 PM Steffen Dirkwinkel <[email protected]> wrote:

...

Quoted 5 lines
Quoted 3 lines

I'm afraid it's a bit too much. Is there any guarantee all the boards based on x86 will be Baytrail only?

Sorry, I guess I should make this clearer in the message. All boards with "CBxx63" are Baytrail.

Quoted 6 lines

Exactly! And this supports my idea that this shouldn't be done like in this patch.
Are you guaranteeing that *all x86-based* boards produced by your company will be Baytrail only?
Above tells that the answer is rather "no". So, I think we can't apply this patch in its current form.

All boards with DMI_PRODUCT_FAMILY="CBxx63" are Baytrail boards. We do produce other x86 boards but the family is exclusive to Baytrail.
I might be misunderstanding how the matching works. Does this match anything other than CBxx63?

.matches = {
DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
DMI_MATCH(DMI_PRODUCT_FAMILY, "CBxx63"), },

I can switch it to DMI_EXACT_MATCH but even substring matching works.

Quoted 5 lines

--
With Best Regards,
Andy Shevchenko

Beckhoff Automation GmbH & Co. KG | Managing Director: Dipl. Phys. Hans Beckhoff Registered office: Verl, Germany | Register court: Guetersloh HRA 7075

Reviewed-by
#5 lore raw
Quoted 7 lines · linux-kernel-dev
Quoted 6 lines · Andy Shevchenko

CAUTION: External Email!!

Quoted 3 lines · linux-kernel-dev
Quoted 2 lines · Andy Shevchenko

On Mon, Apr 12, 2021 at 12:29 PM Steffen Dirkwinkel <[email protected]> wrote:

...

Quoted 17 lines
Quoted 6 lines
Quoted 5 lines
Quoted 3 lines

I'm afraid it's a bit too much. Is there any guarantee all the boards based on x86 will be Baytrail only?

Sorry, I guess I should make this clearer in the message. All boards with "CBxx63" are Baytrail.

Quoted 6 lines

Exactly! And this supports my idea that this shouldn't be done like in this patch.
Are you guaranteeing that *all x86-based* boards produced by your company will be Baytrail only?
Above tells that the answer is rather "no". So, I think we can't apply this patch in its current form.

All boards with DMI_PRODUCT_FAMILY="CBxx63" are Baytrail boards. We do produce other x86 boards but the family is exclusive to Baytrail.
I might be misunderstanding how the matching works. Does this match anything other than CBxx63?

Quoted 6 lines

.matches = {
DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
DMI_MATCH(DMI_PRODUCT_FAMILY, "CBxx63"), },

I can switch it to DMI_EXACT_MATCH but even substring matching works.

Sorry, I missed the second match line. Yes, looks correct to me now.

Signature · 2 lines
With Best Regards,
Andy Shevchenko
#6 lore raw

PATCH v2 1/1 platform/x86: pmc_atom: Match all Beckhoff Automation baytrail boards with critclk_systems DMI table

From: Steffen Dirkwinkel <[email protected]>

pmc_plt_clk* clocks are used for ethernet controllers, so need to stay turned on. This adds the affected board family to critclk_systems DMI table, so the clocks are marked as CLK_CRITICAL and not turned off.

This replaces the previously listed boards with a match for the whole device family CBxx63. CBxx63 matches only baytrail devices. There are new affected boards that would otherwise need to be listed. There are unaffected boards in the family, but having the clocks turned on is not an issue.

Fixes 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
---
 drivers/platform/x86/pmc_atom.c | 28 ++--------------------------
 1 file changed, 2 insertions(+), 26 deletions(-)
drivers/platform/x86/pmc_atom.c +2 -26
index ca684ed760d1..a9d2a4b98e57 100644
@@ -393,34 +393,10 @@ static const struct dmi_system_id critclk_systems[] = {
 	},
 	{
 		/* pmc_plt_clk* - are used for ethernet controllers */
-		.ident = "Beckhoff CB3163",
+		.ident = "Beckhoff Baytrail",
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
-			DMI_MATCH(DMI_BOARD_NAME, "CB3163"),
-		},
-	},
-	{
-		/* pmc_plt_clk* - are used for ethernet controllers */
-		.ident = "Beckhoff CB4063",
-		.matches = {
-			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
-			DMI_MATCH(DMI_BOARD_NAME, "CB4063"),
-		},
-	},
-	{
-		/* pmc_plt_clk* - are used for ethernet controllers */
-		.ident = "Beckhoff CB6263",
-		.matches = {
-			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
-			DMI_MATCH(DMI_BOARD_NAME, "CB6263"),
-		},
-	},
-	{
-		/* pmc_plt_clk* - are used for ethernet controllers */
-		.ident = "Beckhoff CB6363",
-		.matches = {
-			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
-			DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
+			DMI_MATCH(DMI_PRODUCT_FAMILY, "CBxx63"),
 		},
 	},
 	{
Signature · 1 line
2.31.1
#7 lore raw

Hi,

Quoted 12 lines · Steffen Dirkwinkel

From: Steffen Dirkwinkel <[email protected]>

pmc_plt_clk* clocks are used for ethernet controllers, so need to stay turned on. This adds the affected board family to critclk_systems DMI table, so the clocks are marked as CLK_CRITICAL and not turned off.

This replaces the previously listed boards with a match for the whole device family CBxx63. CBxx63 matches only baytrail devices. There are new affected boards that would otherwise need to be listed. There are unaffected boards in the family, but having the clocks turned on is not an issue.

Quoted 3 lines
Fixes 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")

Thank you for your patch, I've applied this patch to my review-hans branch:
https://git.kernel.org/pub/scm/linux/kernel/git/pdx86/platform-drivers-x86.git/log/?h=review-hans

Note it will show up in my review-hans branch once I've pushed my local branch there, which might take a while.

Once I've run some tests on this branch the patches there will be added to the platform-drivers-x86/for-next branch and eventually will be included in the pdx86 pull-request to Linus for the next merge-window.

Regards,

Hans

Quoted 46 lines
---
 drivers/platform/x86/pmc_atom.c | 28 ++--------------------------
 1 file changed, 2 insertions(+), 26 deletions(-)
drivers/platform/x86/pmc_atom.c +2 -26
index ca684ed760d1..a9d2a4b98e57 100644
@@ -393,34 +393,10 @@ static const struct dmi_system_id critclk_systems[] = {
 	},
 	{
 		/* pmc_plt_clk* - are used for ethernet controllers */
-		.ident = "Beckhoff CB3163",
+		.ident = "Beckhoff Baytrail",
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
-			DMI_MATCH(DMI_BOARD_NAME, "CB3163"),
-		},
-	},
-	{
-		/* pmc_plt_clk* - are used for ethernet controllers */
-		.ident = "Beckhoff CB4063",
-		.matches = {
-			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
-			DMI_MATCH(DMI_BOARD_NAME, "CB4063"),
-		},
-	},
-	{
-		/* pmc_plt_clk* - are used for ethernet controllers */
-		.ident = "Beckhoff CB6263",
-		.matches = {
-			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
-			DMI_MATCH(DMI_BOARD_NAME, "CB6263"),
-		},
-	},
-	{
-		/* pmc_plt_clk* - are used for ethernet controllers */
-		.ident = "Beckhoff CB6363",
-		.matches = {
-			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
-			DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
+			DMI_MATCH(DMI_PRODUCT_FAMILY, "CBxx63"),
 		},
 	},
 	{