sched/fair: Fix negative energy delta in find_energy_efficient_cpu()
PATCH 1/1 sched/fair: Fix negative energy delta in find_energy_efficient_cpu()
From: Pierre Gondois <[email protected]>
find_energy_efficient_cpu() (feec()) searches the best energy CPU to place a task on. To do so, compute_energy() estimates the energy impact of placing the task on a CPU, based on CPU and task utilization signals.
Utilization signals can be concurrently updated while evaluating a perf_domain. In some cases, this leads to having a 'negative delta', i.e. placing the task in the perf_domain is seen as an energy gain. Thus, any further energy comparison is biased.
In case of a 'negative delta', return prev_cpu since:
1. a 'negative delta' happens in less than 0.5% of feec() calls, on a Juno with 6 CPUs (4 little, 2 big)
2. it is unlikely to have two consecutive 'negative delta' for a task, so if the first call fails, feec() will correctly place the task in the next feec() call
3. EAS current behavior tends to select prev_cpu if the task doesn't raise the OPP of its current perf_domain. prev_cpu is EAS's generic decision
4. prev_cpu should be preferred to returning an error code. In the latter case, select_idle_sibling() would do the placement, selecting a big (and not energy efficient) CPU. As 3., the task would potentially reside on the big CPU for a long time
The patch also:
a. groups the compute_energy() calls to lower the chances of having
concurrent updates in between the calls
b. skips the base_energy_pd computation if no CPU is available in a
perf_domain
--- kernel/sched/fair.c | 69 +++++++++++++++++++++++++-------------------- 1 file changed, 39 insertions(+), 30 deletions(-)
kernel/sched/fair.c +39 -30
@@ -6594,8 +6594,8 @@ static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) {unsigned long prev_delta =ULONG_MAX , best_delta =ULONG_MAX ;struct root_domain *rd =cpu_rq (smp_processor_id ())->rd; +int cpu, best_energy_cpu = prev_cpu, target =-1 ;unsigned long cpu_cap, util, base_energy =0 ; -int cpu, best_energy_cpu = prev_cpu;struct sched_domain *sd;struct perf_domain *pd;
@@ -6614,19 +6614,18 @@ static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu)if (!sd) goto fail; + target = prev_cpu; +sync_entity_load_avg (&p->se);if (!task_util_est (p)) - goto unlock; + goto fail;for (; pd; pd = pd->next) {unsigned long cur_delta, spare_cap, max_spare_cap =0 ; +bool compute_prev_delta = false;unsigned long base_energy_pd;int max_spare_cap_cpu =-1 ; -/* Compute the 'base' energy of the pd, without @p */ - base_energy_pd =compute_energy (p,-1 , pd); - base_energy += base_energy_pd; -for_each_cpu_and (cpu,perf_domain_span (pd),sched_domain_span (sd)) {if (!cpumask_test_cpu (cpu, p->cpus_ptr))continue ;
@@ -6647,26 +6646,41 @@ static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu)if (!fits_capacity (util, cpu_cap))continue ; -/* Always use prev_cpu as a candidate. */ if (cpu == prev_cpu) { - prev_delta =compute_energy (p, prev_cpu, pd); - prev_delta -= base_energy_pd; - best_delta =min (best_delta, prev_delta); - } - -/* -* Find the CPU with the maximum spare capacity in -* the performance domain -*/ -if (spare_cap > max_spare_cap) { +/* Always use prev_cpu as a candidate. */ + compute_prev_delta = true; + }else if (spare_cap > max_spare_cap) { +/* +* Find the CPU with the maximum spare capacity +* in the performance domain. +*/ max_spare_cap = spare_cap; max_spare_cap_cpu = cpu; } } +if (max_spare_cap_cpu <0 && !compute_prev_delta) +continue ; + +/* Compute the 'base' energy of the pd, without @p */ + base_energy_pd =compute_energy (p,-1 , pd); + base_energy += base_energy_pd; + +if (compute_prev_delta) { + prev_delta =compute_energy (p, prev_cpu, pd); +/* Prevent negative deltas and select prev_cpu */ +if (prev_delta < base_energy_pd) + goto fail; + prev_delta -= base_energy_pd; + best_delta =min (best_delta, prev_delta); + } +/* Evaluate the energy impact of using this CPU. */ -if (max_spare_cap_cpu >=0 && max_spare_cap_cpu != prev_cpu) { +if (max_spare_cap_cpu >=0 ) { cur_delta =compute_energy (p, max_spare_cap_cpu, pd); +/* Prevent negative deltas and select prev_cpu */ +if (cur_delta < base_energy_pd) + goto fail; cur_delta -= base_energy_pd;if (cur_delta < best_delta) { best_delta = cur_delta;
@@ -6674,25 +6688,20 @@ static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) } } } -unlock: -rcu_read_unlock ();/* -* Pick the best CPU if prev_cpu cannot be used, or if it saves at -* least 6% of the energy used by prev_cpu. +* Pick the best CPU if: +* - prev_cpu cannot be used, or +* - it saves at least 6% of the energy used by prev_cpu */ -if (prev_delta ==ULONG_MAX ) -return best_energy_cpu; - -if ((prev_delta - best_delta) > ((prev_delta + base_energy) >>4 )) -return best_energy_cpu; - -return prev_cpu; +if ((prev_delta ==ULONG_MAX ) || + (prev_delta - best_delta) > ((prev_delta + base_energy) >>4 )) + target = best_energy_cpu; fail:rcu_read_unlock (); -return -1 ; +return target; }/*
Signature · 1 line
2.17.1
Dietmar Eggemann
reviewerQuoted 26 lines · On 20/04/2021 14:56, [email protected] wrote:
From: Pierre Gondois <[email protected]>
find_energy_efficient_cpu()(feec()) searches the best energy CPU to place a task on. To do so,compute_energy()estimates the energy impact of placing the task on a CPU, based on CPU and task utilization signals.Utilization signals can be concurrently updated while evaluating a
perf_domain. In some cases, this leads to having a 'negative delta', i.e. placing the task in theperf_domainis seen as an energy gain. Thus, any further energy comparison is biased.In case of a 'negative delta', return
prev_cpusince:
1. a 'negative delta' happens in less than 0.5% offeec()calls, on a Juno with 6 CPUs (4 little, 2 big)
2. it is unlikely to have two consecutive 'negative delta' for a task, so if the first call fails,feec()will correctly place the task in the nextfeec()call
3. EAS current behavior tends to selectprev_cpuif the task doesn't raise the OPP of its currentperf_domain.prev_cpuis EAS's generic decision
4.prev_cpushould be preferred to returning an error code. In the latter case,select_idle_sibling()would do the placement, selecting a big (and not energy efficient) CPU. As 3., the task would potentially reside on the big CPU for a long time
Quoted 5 lines
The patch also:
a. groups thecompute_energy()calls to lower the chances of having
concurrent updates in between the calls
b. skips thebase_energy_pdcomputation if no CPU is available in a
perf_domain
Did you run some tests to make sure you didn't regress on energy consumption? You could run EAS' Energy tests w/ and w/o the patch depicted in:
https://lkml.kernel.org/r/[email protected]
Quoted 70 lines
Fixes eb92692b2544d sched/fair: Speed-up energy-aware wake-upReported-by Xuewen Yan <[email protected]>Suggested-by Xuewen Yan <[email protected]>Signed-off-by Pierre Gondois <[email protected]>--- kernel/sched/fair.c | 69 +++++++++++++++++++++++++-------------------- 1 file changed, 39 insertions(+), 30 deletions(-)kernel/sched/fair.c +12
-17@@ -6594,8 +6594,8 @@ static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) {unsigned long prev_delta =ULONG_MAX , best_delta =ULONG_MAX ;struct root_domain *rd =cpu_rq (smp_processor_id ())->rd; +int cpu, best_energy_cpu = prev_cpu, target =-1 ;unsigned long cpu_cap, util, base_energy =0 ; -int cpu, best_energy_cpu = prev_cpu;struct sched_domain *sd;struct perf_domain *pd;@@ -6614,19 +6614,18 @@ static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu)if (!sd) goto fail; + target = prev_cpu; +sync_entity_load_avg (&p->se);if (!task_util_est (p)) - goto unlock; + goto fail;for (; pd; pd = pd->next) {unsigned long cur_delta, spare_cap, max_spare_cap =0 ; +bool compute_prev_delta = false;unsigned long base_energy_pd;int max_spare_cap_cpu =-1 ; -/* Compute the 'base' energy of the pd, without @p */ - base_energy_pd =compute_energy (p,-1 , pd); - base_energy += base_energy_pd; -for_each_cpu_and (cpu,perf_domain_span (pd),sched_domain_span (sd)) {if (!cpumask_test_cpu (cpu, p->cpus_ptr))continue ;@@ -6647,26 +6646,41 @@ static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu)if (!fits_capacity (util, cpu_cap))continue ; -/* Always use prev_cpu as a candidate. */ if (cpu == prev_cpu) { - prev_delta =compute_energy (p, prev_cpu, pd); - prev_delta -= base_energy_pd; - best_delta =min (best_delta, prev_delta); - } - -/* -* Find the CPU with the maximum spare capacity in -* the performance domain -*/ -if (spare_cap > max_spare_cap) { +/* Always use prev_cpu as a candidate. */ + compute_prev_delta = true; + }else if (spare_cap > max_spare_cap) { +/* +* Find the CPU with the maximum spare capacity +* in the performance domain. +*/ max_spare_cap = spare_cap;
kernel/sched/fair.c static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) · line 6667
Quoted 10 lines
kernel/sched/fair.c +6
-0max_spare_cap_cpu = cpu; } } +if (max_spare_cap_cpu <0 && !compute_prev_delta) +continue ; + +/* Compute the 'base' energy of the pd, without @p */ + base_energy_pd =compute_energy (p,-1 , pd); + base_energy += base_energy_pd;
Maybe add a comment
/* Evaluate the energy impact of using prev_cpu. */
To be in sync with the if condition further below.
kernel/sched/fair.c static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) · line 6671
Quoted 3 lines
kernel/sched/fair.c +3
-0+if (compute_prev_delta) { + prev_delta =compute_energy (p, prev_cpu, pd); +/* Prevent negative deltas and select prev_cpu */
Not sure if this comment helps in understanding the code. We don't comment that we return prev_cpu if !task_util_est(p) or we're not entering the Pick the best CPU ... condition.
kernel/sched/fair.c static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) · line 6678
Quoted 7 lines
kernel/sched/fair.c +6
-0+if (prev_delta < base_energy_pd) + goto fail; + prev_delta -= base_energy_pd; + best_delta =min (best_delta, prev_delta); + } +/* Evaluate the energy impact of using this CPU. */
better
/* Evaluate the energy impact of using max_spare_cap_cpu. */
since this has lost its context.
kernel/sched/fair.c static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) · line 6681
Quoted 4 lines
kernel/sched/fair.c +2
-1-if (max_spare_cap_cpu >=0 && max_spare_cap_cpu != prev_cpu) { +if (max_spare_cap_cpu >=0 ) { cur_delta =compute_energy (p, max_spare_cap_cpu, pd); +/* Prevent negative deltas and select prev_cpu */
Not sure if this comment helps in understanding the code.
kernel/sched/fair.c static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) · line 6678
Quoted 11 lines
kernel/sched/fair.c +2
-2+if (cur_delta < base_energy_pd) + goto fail; cur_delta -= base_energy_pd;if (cur_delta < best_delta) { best_delta = cur_delta;@@ -6674,25 +6688,20 @@ static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) } } } -unlock: -rcu_read_unlock ();
You don't close the RCU read-side critical section here anymore but include the following if condition as well. Don't we always want to close them as quick as possible? We could still return target (prev_cpu) after the if condition below ...
kernel/sched/fair.c static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) · line 6696
Quoted 8 lines
kernel/sched/fair.c +3
-2/* -* Pick the best CPU if prev_cpu cannot be used, or if it saves at -* least 6% of the energy used by prev_cpu. +* Pick the best CPU if: +* - prev_cpu cannot be used, or +* - it saves at least 6% of the energy used by prev_cpu */
Why changing the layout of this comment?
Quoted 20 lines
kernel/sched/fair.c +4
-8-if (prev_delta ==ULONG_MAX ) -return best_energy_cpu; - -if ((prev_delta - best_delta) > ((prev_delta + base_energy) >>4 )) -return best_energy_cpu; - -return prev_cpu; +if ((prev_delta ==ULONG_MAX ) || + (prev_delta - best_delta) > ((prev_delta + base_energy) >>4 )) + target = best_energy_cpu; fail:rcu_read_unlock (); -return -1 ; +return target; }/*
Hi Dietmar,
Thanks for the review,
Quoted 32 lines · Dietmar Eggemann
Quoted 26 lines · On 20/04/2021 14:56, [email protected] wrote:
From: Pierre Gondois <[email protected]>
find_energy_efficient_cpu()(feec()) searches the best energy CPU to place a task on. To do so,compute_energy()estimates the energy impact of placing the task on a CPU, based on CPU and task utilization signals.Utilization signals can be concurrently updated while evaluating a
perf_domain. In some cases, this leads to having a 'negative delta', i.e. placing the task in theperf_domainis seen as an energy gain. Thus, any further energy comparison is biased.In case of a 'negative delta', return
prev_cpusince:
1. a 'negative delta' happens in less than 0.5% offeec()calls, on a Juno with 6 CPUs (4 little, 2 big)
2. it is unlikely to have two consecutive 'negative delta' for a task, so if the first call fails,feec()will correctly place the task in the nextfeec()call
3. EAS current behavior tends to selectprev_cpuif the task doesn't raise the OPP of its currentperf_domain.prev_cpuis EAS's generic decision
4.prev_cpushould be preferred to returning an error code. In the latter case,select_idle_sibling()would do the placement, selecting a big (and not energy efficient) CPU. As 3., the task would potentially reside on the big CPU for a long timeQuoted 5 lines
The patch also:
a. groups thecompute_energy()calls to lower the chances of having
concurrent updates in between the calls
b. skips thebase_energy_pdcomputation if no CPU is available in a
perf_domain
Quoted 5 lines
Did you run some tests to make sure you didn't regress on energy consumption? You could run EAS' Energy tests w/ and w/o the patch depicted in:
I executed the energy test you pointed at using LISA on a Juno-r2 (2xA57 + 4xA53). The initial tests made by Quentin was on a Juno-r0 and a Hikey960.
To recall the test:
"10 iterations of between 10 and 50 periodic rt-app tasks (16ms period, 5% duty-cycle) for 30 seconds with energy measurement. Unit is Joules. The goal is to save energy, so lower is better." "Energy is measured with the onboard energy meter. Numbers include consumption of big and little CPUs."
+----------+-----------------+-------------------------+ | | Without patches | With patches | +----------+--------+--------+------------------+------+ | Tasks nb | Mean | CI* | Mean | CI* | +----------+--------+--------+------------------+------+ | 10 | 6.57 | 0.24 | 6.46 (-1.69%) | 0.16 | | 20 | 12.44 | 0.21 | 12.40 (-0.33%) | 0.11 | | 30 | 19.10 | 0.78 | 18.93 (-0.89%) | 0.46 | | 40 | 27.27 | 0.53 | 27.49 (+0.81% | 0.17 | | 50 | 36.55 | 0.42 | 37.21 (+1.80%) | 0.81 | +----------+-----------------+-------------------------+
CI: confidence interval
For each line, the intervals of values w/ wo/ the patches are overlapping (consider Mean +/- CI). Thus, the energy results shouldn't have been impacted.
Quoted 83 lines
Quoted 70 lines
Fixes eb92692b2544d sched/fair: Speed-up energy-aware wake-upReported-by Xuewen Yan <[email protected]>Suggested-by Xuewen Yan <[email protected]>Signed-off-by Pierre Gondois <[email protected]>--- kernel/sched/fair.c | 69 +++++++++++++++++++++++++-------------------- 1 file changed, 39 insertions(+), 30 deletions(-)kernel/sched/fair.c +12
-17@@ -6594,8 +6594,8 @@ static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) {unsigned long prev_delta =ULONG_MAX , best_delta =ULONG_MAX ;struct root_domain *rd =cpu_rq (smp_processor_id ())->rd; +int cpu, best_energy_cpu = prev_cpu, target =-1 ;unsigned long cpu_cap, util, base_energy =0 ; -int cpu, best_energy_cpu = prev_cpu;struct sched_domain *sd;struct perf_domain *pd;@@ -6614,19 +6614,18 @@ static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu)if (!sd) goto fail; + target = prev_cpu; +sync_entity_load_avg (&p->se);if (!task_util_est (p)) - goto unlock; + goto fail;for (; pd; pd = pd->next) {unsigned long cur_delta, spare_cap, max_spare_cap =0 ; +bool compute_prev_delta = false;unsigned long base_energy_pd;int max_spare_cap_cpu =-1 ; -/* Compute the 'base' energy of the pd, without @p */ - base_energy_pd =compute_energy (p,-1 , pd); - base_energy += base_energy_pd; -for_each_cpu_and (cpu,perf_domain_span (pd),sched_domain_span (sd)) {if (!cpumask_test_cpu (cpu, p->cpus_ptr))continue ;@@ -6647,26 +6646,41 @@ static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu)if (!fits_capacity (util, cpu_cap))continue ; -/* Always use prev_cpu as a candidate. */ if (cpu == prev_cpu) { - prev_delta =compute_energy (p, prev_cpu, pd); - prev_delta -= base_energy_pd; - best_delta =min (best_delta, prev_delta); - } - -/* -* Find the CPU with the maximum spare capacity in -* the performance domain -*/ -if (spare_cap > max_spare_cap) { +/* Always use prev_cpu as a candidate. */ + compute_prev_delta = true; + }else if (spare_cap > max_spare_cap) { +/* +* Find the CPU with the maximum spare capacity +* in the performance domain. +*/ max_spare_cap = spare_cap;kernel/sched/fair.c static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) · line 6667
Quoted 10 lines
kernel/sched/fair.c +6
-0max_spare_cap_cpu = cpu; } } +if (max_spare_cap_cpu <0 && !compute_prev_delta) +continue ; + +/* Compute the 'base' energy of the pd, without @p */ + base_energy_pd =compute_energy (p,-1 , pd); + base_energy += base_energy_pd;Maybe add a comment
Quoted 3 lines
/* Evaluate the energy impact of using prev_cpu. */To be in sync with the if condition further below.
Ok
Quoted 7 lines
kernel/sched/fair.c static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) · line 6671
Quoted 4 lines
kernel/sched/fair.c +3
-0+if (compute_prev_delta) { + prev_delta =compute_energy (p, prev_cpu, pd); +/* Prevent negative deltas and select prev_cpu */ Not sure if this comment helps in understanding the code. We don't comment that we return
prev_cpuif !task_util_est(p) or we're not entering thePick the best CPU ...condition.
I thought it was not obvious how (prev_delta < base_energy_pd) could happen. I'm ok to remove the comment, but maybe a sentence should be added in the function header or somewhere else.
Quoted 10 lines
kernel/sched/fair.c static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) · line 6678
Quoted 8 lines
kernel/sched/fair.c +6
-0+if (prev_delta < base_energy_pd) + goto fail; + prev_delta -= base_energy_pd; + best_delta =min (best_delta, prev_delta); + } +/* Evaluate the energy impact of using this CPU. */ better
Quoted 3 lines
/* Evaluate the energy impact of using max_spare_cap_cpu. */since
thishas lost its context.
Ok
Quoted 6 lines
kernel/sched/fair.c static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) · line 6681
Quoted 5 lines
kernel/sched/fair.c +2
-1-if (max_spare_cap_cpu >=0 && max_spare_cap_cpu != prev_cpu) { +if (max_spare_cap_cpu >=0 ) { cur_delta =compute_energy (p, max_spare_cap_cpu, pd); +/* Prevent negative deltas and select prev_cpu */ Not sure if this comment helps in understanding the code.
Same comment: I'm ok to remove it, but we should explain what happens somewhere, maybe in the function header.
Quoted 16 lines
kernel/sched/fair.c static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) · line 6678
Quoted 12 lines
kernel/sched/fair.c +2
-2+if (cur_delta < base_energy_pd) + goto fail; cur_delta -= base_energy_pd;if (cur_delta < best_delta) { best_delta = cur_delta;@@ -6674,25 +6688,20 @@ static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) } } } -unlock: -rcu_read_unlock ();You don't close the RCU read-side critical section here anymore but include the following if condition as well. Don't we always want to close them as quick as possible? We could still return target (
prev_cpu) after the if condition below ...
The computation should not take that long and this would make less code.
Putting back the rcu_read_unlock() and returning faster instead of having a fall-through would also work for me.
Quoted 9 lines
kernel/sched/fair.c static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) · line 6696
Quoted 8 lines
kernel/sched/fair.c +3
-2/* -* Pick the best CPU if prev_cpu cannot be used, or if it saves at -* least 6% of the energy used by prev_cpu. +* Pick the best CPU if: +* - prev_cpu cannot be used, or +* - it saves at least 6% of the energy used by prev_cpu */ Why changing the layout of this comment?
I thought it was clearer to have bullet points. It can be reverted.
Quoted 20 lines
Quoted 20 lines
kernel/sched/fair.c +4
-8-if (prev_delta ==ULONG_MAX ) -return best_energy_cpu; - -if ((prev_delta - best_delta) > ((prev_delta + base_energy) >>4 )) -return best_energy_cpu; - -return prev_cpu; +if ((prev_delta ==ULONG_MAX ) || + (prev_delta - best_delta) > ((prev_delta + base_energy) >>4 )) + target = best_energy_cpu; fail:rcu_read_unlock (); -return -1 ; +return target; }/*
Dietmar Eggemann
reviewerQuoted 7 lines · Pierre Gondois
Hi Dietmar,
Thanks for the review,Quoted 2 lines · Dietmar Eggemann
Quoted 1 line · On 20/04/2021 14:56, [email protected] wrote:
From: Pierre Gondois <[email protected]>
[...]
Quoted 29 lines
Quoted 5 lines
Did you run some tests to make sure you didn't regress on energy consumption? You could run EAS' Energy tests w/ and w/o the patch depicted in:
I executed the energy test you pointed at using LISA on a Juno-r2 (2xA57
+ 4xA53). The initial tests made by Quentin was on a Juno-r0 and a Hikey960.To recall the test:
"10 iterations of between 10 and 50 periodic rt-app tasks (16ms period, 5% duty-cycle) for 30 seconds with energy measurement. Unit is Joules. The goal is to save energy, so lower is better."
"Energy is measured with the onboard energy meter. Numbers include consumption of big and little CPUs."+----------+-----------------+-------------------------+ | | Without patches | With patches | +----------+--------+--------+------------------+------+ | Tasks nb | Mean | CI* | Mean | CI* | +----------+--------+--------+------------------+------+ | 10 | 6.57 | 0.24 | 6.46 (-1.69%) | 0.16 | | 20 | 12.44 | 0.21 | 12.40 (-0.33%) | 0.11 | | 30 | 19.10 | 0.78 | 18.93 (-0.89%) | 0.46 | | 40 | 27.27 | 0.53 | 27.49 (+0.81% | 0.17 | | 50 | 36.55 | 0.42 | 37.21 (+1.80%) | 0.81 | +----------+-----------------+-------------------------+
Quoted 5 lines
CI: confidence interval
For each line, the intervals of values w/ wo/ the patches are overlapping (consider Mean +/- CI). Thus, the energy results shouldn't have been impacted.
Put this into the patch header so people see some testing has been done.
[...]
Quoted 9 lines
Quoted 6 lines
Quoted 3 lines
+ if (
compute_prev_delta) {
+prev_delta=compute_energy(p, prev_cpu, pd); + /* Prevent negative deltas and selectprev_cpu*/Not sure if this comment helps in understanding the code. We don't comment that we return
prev_cpuif !task_util_est(p) or we're not entering thePick the best CPU ...condition.I thought it was not obvious how (
prev_delta<base_energy_pd) could happen. I'm ok to remove the comment, but maybe a sentence should be added in the function header or somewhere else.
Agreed. Remove the commend and add text in the patch header to illustrate how you fix negative energy delta ....
[...]
Quoted 2 lines
Same comment: I'm ok to remove it, but we should explain what happens somewhere, maybe in the function header.
Same here.
[...]
Quoted 11 lines
Quoted 11 lines
kernel/sched/fair.c static int find_energy_efficient_cpu(struct · line 6679
Quoted 7 lines
kernel/sched/fair.c +0
-2@@ -6674,25 +6688,20 @@ static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) } } } -unlock: - rcu_read_unlock();You don't close the RCU read-side critical section here anymore but include the following if condition as well. Don't we always want to close them as quick as possible? We could still return target (
prev_cpu) after the if condition below ...
Quoted 3 lines
The computation should not take that long and this would make less code. Putting back the
rcu_read_unlock()and returning faster instead of having a fall-through would also work for me.
I see but I would stay on the save side and keep the RCU read-side critical section as short as possible.
Quoted 10 lines
Quoted 8 lines
kernel/sched/fair.c static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) · line 6696
Quoted 7 lines
kernel/sched/fair.c +3
-2/* -* Pick the best CPU if prev_cpu cannot be used, or if it saves at -* least 6% of the energy used by prev_cpu. +* Pick the best CPU if: +* - prev_cpu cannot be used, or +* - it saves at least 6% of the energy used by prev_cpu */ Why changing the layout of this comment?
I thought it was clearer to have bullet points. It can be reverted.
Please revert. Keep the changes as small as possible.
[...]
Hi Pierre,
Quoted 26 lines · On Tuesday 20 Apr 2021 at 13:56:04 (+0100), [email protected] wrote:
From: Pierre Gondois <[email protected]>
find_energy_efficient_cpu()(feec()) searches the best energy CPU to place a task on. To do so,compute_energy()estimates the energy impact of placing the task on a CPU, based on CPU and task utilization signals.Utilization signals can be concurrently updated while evaluating a
perf_domain. In some cases, this leads to having a 'negative delta', i.e. placing the task in theperf_domainis seen as an energy gain. Thus, any further energy comparison is biased.In case of a 'negative delta', return
prev_cpusince:
1. a 'negative delta' happens in less than 0.5% offeec()calls, on a Juno with 6 CPUs (4 little, 2 big)
2. it is unlikely to have two consecutive 'negative delta' for a task, so if the first call fails,feec()will correctly place the task in the nextfeec()call
3. EAS current behavior tends to selectprev_cpuif the task doesn't raise the OPP of its currentperf_domain.prev_cpuis EAS's generic decision
4.prev_cpushould be preferred to returning an error code. In the latter case,select_idle_sibling()would do the placement, selecting a big (and not energy efficient) CPU. As 3., the task would potentially reside on the big CPU for a long time
Quoted 5 lines
The patch also:
a. groups thecompute_energy()calls to lower the chances of having
concurrent updates in between the calls
b. skips thebase_energy_pdcomputation if no CPU is available in a
perf_domain
Should these be separate patches? That would make things a little easier to review.
Quoted 1 line
Fixes eb92692b2544d sched/fair: Speed-up energy-aware wake-up
Hmm, dunno if this really wants a Fixes: tag at all, but if it does I don't think that will be this commit. We had the same 'issue' even before this optimization no?
Quoted 22 lines
Reported-by Xuewen Yan <[email protected]>Suggested-by Xuewen Yan <[email protected]>Signed-off-by Pierre Gondois <[email protected]>--- kernel/sched/fair.c | 69 +++++++++++++++++++++++++-------------------- 1 file changed, 39 insertions(+), 30 deletions(-)kernel/sched/fair.c +1
-1@@ -6594,8 +6594,8 @@ static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) {unsigned long prev_delta =ULONG_MAX , best_delta =ULONG_MAX ;struct root_domain *rd =cpu_rq (smp_processor_id ())->rd; +int cpu, best_energy_cpu = prev_cpu, target =-1 ;unsigned long cpu_cap, util, base_energy =0 ; -int cpu, best_energy_cpu = prev_cpu;struct sched_domain *sd;struct perf_domain *pd;
kernel/sched/fair.c static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) · line 6621
Quoted 9 lines
kernel/sched/fair.c +3
-1@@ -6614,19 +6614,18 @@ static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu)if (!sd) goto fail; + target = prev_cpu; +sync_entity_load_avg (&p->se);if (!task_util_est (p)) - goto unlock; + goto fail;
Maybe s/fail/unlock/ or something? This is not a failure per se, just an optimization -- if the task util is 0, it's impact on the EM will always be 0, so we'll pick prev_cpu every time.
Quoted 48 lines
kernel/sched/fair.c +14
-15for (; pd; pd = pd->next) {unsigned long cur_delta, spare_cap, max_spare_cap =0 ; +bool compute_prev_delta = false;unsigned long base_energy_pd;int max_spare_cap_cpu =-1 ; -/* Compute the 'base' energy of the pd, without @p */ - base_energy_pd =compute_energy (p,-1 , pd); - base_energy += base_energy_pd; -for_each_cpu_and (cpu,perf_domain_span (pd),sched_domain_span (sd)) {if (!cpumask_test_cpu (cpu, p->cpus_ptr))continue ;@@ -6647,26 +6646,41 @@ static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu)if (!fits_capacity (util, cpu_cap))continue ; -/* Always use prev_cpu as a candidate. */ if (cpu == prev_cpu) { - prev_delta =compute_energy (p, prev_cpu, pd); - prev_delta -= base_energy_pd; - best_delta =min (best_delta, prev_delta); - } - -/* -* Find the CPU with the maximum spare capacity in -* the performance domain -*/ -if (spare_cap > max_spare_cap) { +/* Always use prev_cpu as a candidate. */ + compute_prev_delta = true; + }else if (spare_cap > max_spare_cap) { +/* +* Find the CPU with the maximum spare capacity +* in the performance domain. +*/ max_spare_cap = spare_cap; max_spare_cap_cpu = cpu; } } +if (max_spare_cap_cpu <0 && !compute_prev_delta) +continue ; + +/* Compute the 'base' energy of the pd, without @p */ + base_energy_pd =compute_energy (p,-1 , pd); + base_energy += base_energy_pd;
kernel/sched/fair.c static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) · line 6677
Quoted 10 lines
kernel/sched/fair.c +10
-0+ +if (compute_prev_delta) { + prev_delta =compute_energy (p, prev_cpu, pd); +/* Prevent negative deltas and select prev_cpu */ +if (prev_delta < base_energy_pd) + goto fail; + prev_delta -= base_energy_pd; + best_delta =min (best_delta, prev_delta); + } +
Not that I disagree with the approach, just being curious: do we know how much this is helping in practice to reduce the window by moving the compute_energy() calls down here?
Quoted 31 lines
kernel/sched/fair.c +7
-12/* Evaluate the energy impact of using this CPU. */ -if (max_spare_cap_cpu >=0 && max_spare_cap_cpu != prev_cpu) { +if (max_spare_cap_cpu >=0 ) { cur_delta =compute_energy (p, max_spare_cap_cpu, pd); +/* Prevent negative deltas and select prev_cpu */ +if (cur_delta < base_energy_pd) + goto fail; cur_delta -= base_energy_pd;if (cur_delta < best_delta) { best_delta = cur_delta;@@ -6674,25 +6688,20 @@ static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) } } } -unlock: -rcu_read_unlock ();/* -* Pick the best CPU if prev_cpu cannot be used, or if it saves at -* least 6% of the energy used by prev_cpu. +* Pick the best CPU if: +* - prev_cpu cannot be used, or +* - it saves at least 6% of the energy used by prev_cpu */ -if (prev_delta ==ULONG_MAX ) -return best_energy_cpu; - -if ((prev_delta - best_delta) > ((prev_delta + base_energy) >>4 )) -return best_energy_cpu; - -return prev_cpu;
kernel/sched/fair.c static int find_energy_efficient_cpu(struct task_struct *p, int prev_cpu) · line 6705
Quoted 10 lines
kernel/sched/fair.c +4
-1+if ((prev_delta ==ULONG_MAX ) || + (prev_delta - best_delta) > ((prev_delta + base_energy) >>4 )) + target = best_energy_cpu; fail:rcu_read_unlock (); -return -1 ; +return target; }
Otherwise this looks pretty good to me.
Thanks,
Quentin
Hi Quentin,
I sent a v2 yesterday. This is just to answer your question:
Quoted 3 lines
Not that I disagree with the approach, just being curious: do we know how much this is helping in practice to reduce the window by moving the
compute_energy()calls down here?
I don't have any numbers. However, moving the computation of base_energy_pd
after looping over the CPUs of a performance domain allows to skip this computation
if no CPU is available in the performance domain. This should justify moving the
compute_energy() call.
Regards,
Pierre