Skip to contentSkip to conversation

hwmon: (adt7462) Add settings for manual fan control.

PATCH In review Ashwin H 2 participants 2 messages May 17, 2021

Subsystems (2)
lore
Share & tools
lore

Ashwin H

author
#0 lore raw

PATCH 1/1 hwmon: (adt7462) Add settings for manual fan control.

ADT7462 can operate in manual mode for fan control. Currently if we want to read fan speed,
there is a check if TACH measurement is enabled for a fan. (In fan_enabled function).
There is no way to enable TACH measurement currently. This is addressed in this commit.

Along with the above support few more features are enabled
- Support for setting fan presence.
- Support for setting low and high frequency mode.
- Support for setting easy config option.
- Support for setting the duration of the fan startup timeout.
- Once the setting is done, there is a setup complete bit in cfg1 register. Settings this bit will start the monitoring of all selected channels. Added support for that.

Based on this, below is the flow to set/get fan speed (example:pwm1)

echo 1 > pwm1_enable            #Set to manual mode
echo 1 > pwm_freq_mode          #High freq mode (optional.newly added)
echo 1 > fan1_presence          #Set fan 1 as present(newly added)
echo 1 > fan1_tach_enable       #Start TACH measurement-fan1(newly added)
echo 1 > setup_complete         #Mark as setup complete (newly added)
cat fan1_input                  #Read Fan1 RPM.
echo 192 > pwm1                 #Change PWM1(has fan1) to 75%(192/255).

This is tested on x86 CPU which connects via PCIE to FGPA which has I2C Controller. ADT7462 is connected to the I2C controller(on FPGA).

---
 Documentation/hwmon/adt7462.rst |  22 ++-
 drivers/hwmon/adt7462.c         | 308 ++++++++++++++++++++++++++++++++
 2 files changed, 329 insertions(+), 1 deletion(-)
Documentation/hwmon/adt7462.rst +21 -1
index 139e19696188..a4418ed6f2fa 100644
@@ -56,7 +56,7 @@ Configuration Notes
 
 Besides standard interfaces driver adds the following:
 
-* PWM Control
+* PWM Auto Control
 
 * pwm#_auto_point1_pwm and temp#_auto_point1_temp and
 * pwm#_auto_point2_pwm and temp#_auto_point2_temp -
@@ -68,3 +68,23 @@ The ADT7462 will scale the pwm between the lower and higher pwm speed when
 the temperature is between the two temperature boundaries.  PWM values range
 from 0 (off) to 255 (full speed).  Fan speed will be set to maximum when the
 temperature sensor associated with the PWM control exceeds temp#_max.
+
+* PWM Manual Control
+The ADT7462 can operate in manual mode for PWM control.
+Below is the typical flow to contol PWM manually.
+(Example for PWM1 which controls fan1)
+
+  - Set PWM to manual mode
+    - echo 1 > pwm1_enable
+  - Enable High Freq Mode (optional)
+    -  echo 1 > pwm_freq_mode
+  - Set fan1 as present
+    - echo 1 > fan1_presence
+  - Start TACH measurement for fan1
+    - echo 1 > fan1_tach_enable
+  - Mark as setup complete. This will start monitoring of all enabled channels.
+    - echo 1 > setup_complete
+  - Read fan1 RPM
+    -  cat fan1_input
+  - Change PWM1 to 75% (192/255)
+    - echo 192 > pwm1
drivers/hwmon/adt7462.c +308 -0

400 lines not on this page · raw message

Signature · 1 line
2.31.1
maintainer
#1 lore raw
Quoted 16 lines · Ashwin H

ADT7462 can operate in manual mode for fan control. Currently if we want to read fan speed,
there is a check if TACH measurement is enabled for a fan. (In fan_enabled function).
There is no way to enable TACH measurement currently. This is addressed in this commit.

Along with the above support few more features are enabled
- Support for setting fan presence.
- Support for setting low and high frequency mode.
- Support for setting easy config option.
- Support for setting the duration of the fan startup timeout.
- Once the setting is done, there is a setup complete bit in cfg1 register. Settings this bit will start the monitoring of all selected channels. Added support for that.

Quoted 7 lines

Based on this, below is the flow to set/get fan speed (example:pwm1)

echo 1 > pwm1_enable            #Set to manual mode
echo 1 > pwm_freq_mode          #High freq mode (optional.newly added)
echo 1 > fan1_presence          #Set fan 1 as present(newly added)
echo 1 > fan1_tach_enable       #Start TACH measurement-fan1(newly added)
echo 1 > setup_complete         #Mark as setup complete (newly added)

Please refrain from adding non-standard attributes. Several of the above non-standard attributes can be expressed as standard attributes, which is even less acceptable.

Also, please follow Documentation/process/submitting-patches.rst, which clearly states

Separate each **logical change** into a separate patch.

Guenter