Python: delint python library
v2 cover Python: delint python library
gitlab CI: https://gitlab.com/jsnow/qemu/-/pipelines/304224309
branch: https://gitlab.com/jsnow/qemu/-/commits/python-package-pre-cleanup
This series serves as a pre-requisite for packaging the python series and getting the linters running via CI. The first patch fixes a linter error we've had for a while now; the subsequent ones fix a new warning that was recently added to pylint 2.8.x.
V2:
- iotest bits already handled, dropped here.
- Changed patch #3 based on feedback from Wainer.
John Snow (6):
python/console_socket: avoid one-letter variable python/machine: use subprocess.DEVNULL instead of
open(os.path.devnull)
python/machine: use subprocess.run instead of subprocess.Popen python/console_socket: Add a pylint ignore python/machine: Disable pylint warning for open() in _pre_launch python/machine: disable warning for Popen in _launch()
python/qemu/console_socket.py | 11 ++++++----- python/qemu/machine.py | 28 ++++++++++++++++++---------- 2 files changed, 24 insertions(+), 15 deletions(-)
Signature · 1 line
2.30.2
PATCH v2 1/6 python/console_socket: avoid one-letter variable
Fixes pylint warnings.
--- python/qemu/console_socket.py | 10 +++++----- 1 file changed, 5 insertions(+), 5 deletions(-)
python/qemu/console_socket.py +5 -5
@@ -46,11 +46,11 @@ def __init__(self, address: str, file: Optional[str] = None, self._drain_thread = self._thread_start() def __repr__(self) -> str: - s = super().__repr__() - s = s.rstrip(">") - s = "%s, logfile=%s, drain_thread=%s>" % (s, self._logfile, - self._drain_thread) - return s + tmp = super().__repr__() + tmp = tmp.rstrip(">") + tmp = "%s, logfile=%s, drain_thread=%s>" % (tmp, self._logfile, + self._drain_thread) + return tmp def _drain_fn(self) -> None: """Drains the socket and runs while the socket is open."""
Signature · 1 line
2.30.2
PATCH v2 2/6 python/machine: use subprocess.DEVNULL instead of open(os.path.devnull)
In reply to John SnowOne less file resource to manage, and it helps quiet some pylint >= 2.8.0 warnings about not using a with-context manager for the open call.
--- python/qemu/machine.py | 6 ++---- 1 file changed, 2 insertions(+), 4 deletions(-)
python/qemu/machine.py +2 -4
@@ -223,9 +223,8 @@ def send_fd_scm(self, fd: Optional[int] = None, assert fd is not None fd_param.append(str(fd)) - devnull = open(os.path.devnull, 'rb') proc = subprocess.Popen( - fd_param, stdin=devnull, stdout=subprocess.PIPE, + fd_param, stdin=subprocess.DEVNULL, stdout=subprocess.PIPE, stderr=subprocess.STDOUT, close_fds=False ) output = proc.communicate()[0]
@@ -393,7 +392,6 @@ def _launch(self) -> None: """ Launch the VM and establish a QMP connection """ - devnull = open(os.path.devnull, 'rb') self._pre_launch() self._qemu_full_args = tuple( chain(self._wrapper,
@@ -403,7 +401,7 @@ def _launch(self) -> None: ) LOG.debug('VM launch command: %r', ' '.join(self._qemu_full_args)) self._popen = subprocess.Popen(self._qemu_full_args, - stdin=devnull, + stdin=subprocess.DEVNULL, stdout=self._qemu_log_file, stderr=subprocess.STDOUT, shell=False,
Signature · 1 line
2.30.2
Re: [PATCH v2 2/6] python/machine: use subprocess.DEVNULL instead of open(os.path.devnull)
Quoted 9 lines · John Snow
One less file resource to manage, and it helps quiet some pylint >= 2.8.0 warnings about not using a with-context manager for the open call.
Signed-off-by John Snow <[email protected]>Reviewed-by Philippe Mathieu-Daudé <[email protected]>--- python/qemu/machine.py | 6 ++---- 1 file changed, 2 insertions(+), 4 deletions(-)
PATCH v2 3/6 python/machine: use subprocess.run instead of subprocess.Popen
In reply to John Snowuse run() instead of Popen() -- to assert to pylint that we are not forgetting to close a long-running program.
--- python/qemu/machine.py | 15 +++++++++------ 1 file changed, 9 insertions(+), 6 deletions(-)
python/qemu/machine.py +9 -6
@@ -223,13 +223,16 @@ def send_fd_scm(self, fd: Optional[int] = None, assert fd is not None fd_param.append(str(fd)) - proc = subprocess.Popen( - fd_param, stdin=subprocess.DEVNULL, stdout=subprocess.PIPE, - stderr=subprocess.STDOUT, close_fds=False + proc = subprocess.run( + fd_param, + stdin=subprocess.DEVNULL, + stdout=subprocess.PIPE, + stderr=subprocess.STDOUT, + check=False, + close_fds=False, ) - output = proc.communicate()[0] - if output: - LOG.debug(output) + if proc.stdout: + LOG.debug(proc.stdout) return proc.returncode
Signature · 1 line
2.30.2
Re: [PATCH v2 3/6] python/machine: use subprocess.run instead of subprocess.Popen
Quoted 8 lines · John Snow
use
run()instead ofPopen()-- to assert to pylint that we are not forgetting to close a long-running program.Signed-off-by John Snow <[email protected]>--- python/qemu/machine.py | 15 +++++++++------ 1 file changed, 9 insertions(+), 6 deletions(-)
qemu-iotests 045 and 147 are happy, so:
PATCH v2 4/6 python/console_socket: Add a pylint ignore
In reply to John SnowWe manage cleaning up this resource ourselves. Pylint should shush.
--- python/qemu/console_socket.py | 1 + 1 file changed, 1 insertion(+)
python/qemu/console_socket.py +1 -0
@@ -39,6 +39,7 @@ def __init__(self, address: str, file: Optional[str] = None, self.connect(address) self._logfile = None if file: + # pylint: disable=consider-using-with self._logfile = open(file, "bw") self._open = True self._drain_thread = None
Signature · 1 line
2.30.2
Re: [PATCH v2 4/6] python/console_socket: Add a pylint ignore
Quoted 7 lines · John Snow
We manage cleaning up this resource ourselves. Pylint should shush.
Signed-off-by John Snow <[email protected]>--- python/qemu/console_socket.py | 1 + 1 file changed, 1 insertion(+)
PATCH v2 5/6 python/machine: Disable pylint warning for open() in _pre_launch
In reply to John SnowShift the open() call later so that the pylint pragma applies *only* to that one open() call. Add a note that suggests why this is safe: the resource is unconditionally cleaned up in _post_shutdown().
_post_shutdown is called after failed launches (see launch()), and unconditionally after every call to shutdown(), and therefore also on __exit__.
--- python/qemu/machine.py | 6 +++++- 1 file changed, 5 insertions(+), 1 deletion(-)
python/qemu/machine.py +5 -1
@@ -308,7 +308,6 @@ def _pre_launch(self) -> None: self._temp_dir = tempfile.mkdtemp(prefix="qemu-machine-", dir=self._test_dir) self._qemu_log_path = os.path.join(self._temp_dir, self._name + ".log") - self._qemu_log_file = open(self._qemu_log_path, 'wb') if self._console_set: self._remove_files.append(self._console_address)
@@ -323,6 +322,11 @@ def _pre_launch(self) -> None: nickname=self._name ) + # NOTE: Make sure any opened resources are *definitely* freed in + # _post_shutdown()! + # pylint: disable=consider-using-with + self._qemu_log_file = open(self._qemu_log_path, 'wb') + def _post_launch(self) -> None: if self._qmp_connection: self._qmp.accept()
Signature · 1 line
2.30.2
Re: [PATCH v2 5/6] python/machine: Disable pylint warning for open() in _pre_launch
Quoted 8 lines · John Snow
Shift the
open()call later so that the pylint pragma applies *only* to that oneopen()call. Add a note that suggests why this is safe: the resource is unconditionally cleaned up in_post_shutdown().
_post_shutdownis called after failed launches (seelaunch()), and unconditionally after every call toshutdown(), and therefore also on__exit__.
Quoted 6 lines
Signed-off-by John Snow <[email protected]>Reviewed-by Wainer dos Santos Moschetta <[email protected]>--- python/qemu/machine.py | 6 +++++- 1 file changed, 5 insertions(+), 1 deletion(-)
PATCH v2 6/6 python/machine: disable warning for Popen in _launch()
In reply to John SnowWe handle this resource rather meticulously in shutdown/kill/wait/__exit__ et al, through the laborious mechanisms in _do_shutdown().
Quiet this pylint warning here.
--- python/qemu/machine.py | 3 +++ 1 file changed, 3 insertions(+)
python/qemu/machine.py +3 -0
@@ -407,6 +407,9 @@ def _launch(self) -> None: self._args) ) LOG.debug('VM launch command: %r', ' '.join(self._qemu_full_args)) + + # Cleaning up of this subprocess is guaranteed by _do_shutdown. + # pylint: disable=consider-using-with self._popen = subprocess.Popen(self._qemu_full_args, stdin=subprocess.DEVNULL, stdout=self._qemu_log_file,
Signature · 1 line
2.30.2
Re: [PATCH v2 6/6] python/machine: disable warning for Popen in _launch()
Quoted 11 lines · John Snow
We handle this resource rather meticulously in shutdown/kill/wait/__exit__ et al, through the laborious mechanisms in
_do_shutdown().Quiet this pylint warning here.
Signed-off-by John Snow <[email protected]>--- python/qemu/machine.py | 3 +++ 1 file changed, 3 insertions(+)
Quoted 21 lines · John Snow
gitlab CI: https://gitlab.com/jsnow/qemu/-/pipelines/304224309
branch: https://gitlab.com/jsnow/qemu/-/commits/python-package-pre-cleanupThis series serves as a pre-requisite for packaging the python series and getting the linters running via CI. The first patch fixes a linter error we've had for a while now; the subsequent ones fix a new warning that was recently added to pylint 2.8.x.
V2:
- iotest bits already handled, dropped here.
- Changed patch #3 based on feedback from Wainer.John Snow (6):
python/console_socket: avoid one-letter variable python/machine: use subprocess.DEVNULL instead of
open(os.path.devnull)
python/machine: use subprocess.run instead of subprocess.Popen python/console_socket: Add a pylint ignore python/machine: Disable pylint warning foropen()in_pre_launchpython/machine: disable warning for Popen in_launch()
Quoted 4 lines
python/qemu/console_socket.py | 11 ++++++----- python/qemu/machine.py | 28 ++++++++++++++++++---------- 2 files changed, 24 insertions(+), 15 deletions(-)
Thank you for reviews! Staged to my Python branch.
--js