Add allowed CPU capacity knowledge to EAS
Subsystems (5)
Lukasz Luba
maintainerv4 cover Add allowed CPU capacity knowledge to EAS
Hi all,
The patch set v4 aims to add knowledge about reduced CPU capacity into the Energy Model (EM) and Energy Aware Scheduler (EAS). Currently the issue is that SchedUtil CPU frequency and EM frequency are not aligned, when there is a CPU thermal capping. This causes an estimation error. This patch set provides the information about allowed CPU capacity into the EM (thanks to thermal pressure information). This improves the energy estimation. More info about this mechanism can be found in the patches description.
Changelog:
v4:
- removed local variable and improved description in patch 2/3
- added Reviewed-by from Vincent for patch 2/3
- added Acked-by from Viresh for patch 1/3
v3 [3]:
- switched to 'raw' per-cpu thermal pressure instead of thermal pressure geometric series signal, since it more suited for purpose of this use case: predicting SchedUtil frequency (Vincent, Dietmar)
- added more comment in the patch 2/3 header for use case when thermal capping might be applied even the CPUs are not over-utilized (Dietmar)
- added ACK tag from Rafael for SchedUtil part
- added a fix patch for offline CPUs in cpufreq_cooling and per-cpu thermal_pressure missing update
v2 [2]:
- clamp the returned value from effective_cpu_util() and avoid irq util scaling issues (Quentin)
v1 is available at [1]
Regards,
Lukasz
[1] https://lore.kernel.org/linux-pm/[email protected]/
[2] https://lore.kernel.org/lkml/[email protected]/
[3] https://lore.kernel.org/lkml/[email protected]/
Lukasz Luba (3):
thermal: cpufreq_cooling: Update also offline CPUs per-cpu
thermal_pressure
sched/fair: Take thermal pressure into account while estimating energy sched/cpufreq: Consider reduced CPU capacity in energy calculation
drivers/thermal/cpufreq_cooling.c | 2 +- include/linux/energy_model.h | 16 +++++++++++++--- include/linux/sched/cpufreq.h | 2 +- kernel/sched/cpufreq_schedutil.c | 1 + kernel/sched/fair.c | 13 +++++++++---- 5 files changed, 25 insertions(+), 9 deletions(-)
Signature · 1 line
2.17.1
Lukasz Luba
maintainerPATCH v4 1/3 thermal: cpufreq_cooling: Update also offline CPUs per-cpu thermal_pressure
The thermal pressure signal gives information to the scheduler about reduced CPU capacity due to thermal. It is based on a value stored in a per-cpu 'thermal_pressure' variable. The online CPUs will get the new value there, while the offline won't. Unfortunately, when the CPU is back online, the value read from per-cpu variable might be wrong (stale data). This might affect the scheduler decisions, since it sees the CPU capacity differently than what is actually available.
Fix it by making sure that all online+offline CPUs would get the proper value in their per-cpu variable when thermal framework sets capping.
--- drivers/thermal/cpufreq_cooling.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/thermal/cpufreq_cooling.c +1 -1
@@ -478,7 +478,7 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, ret =freq_qos_update_request (&cpufreq_cdev->qos_req, frequency);if (ret >=0 ) { cpufreq_cdev->cpufreq_state = state; - cpus = cpufreq_cdev->policy->cpus; + cpus = cpufreq_cdev->policy->related_cpus; max_capacity =arch_scale_cpu_capacity (cpumask_first (cpus)); capacity = frequency * max_capacity; capacity /= cpufreq_cdev->policy->cpuinfo.max_freq;
Signature · 1 line
2.17.1
[tip: sched/core] thermal/cpufreq_cooling: Update offline CPUs per-cpu thermal_pressure
The following commit has been merged into the sched/core branch of tip:
The following commit has been merged into the sched/core branch of tip:
Commit-ID: 2ad8ccc17d1e4270cf65a3f2a07a7534aa23e3fb Gitweb: https://git.kernel.org/tip/2ad8ccc17d1e4270cf65a3f2a07a7534aa23e3fb Author: Lukasz Luba <[email protected]> AuthorDate: Mon, 14 Jun 2021 20:10:30 +01:00 Committer: Peter Zijlstra <[email protected]> CommitterDate: Thu, 17 Jun 2021 14:11:43 +02:00
thermal/cpufreq_cooling: Update offline CPUs per-cpu thermal_pressure
The thermal pressure signal gives information to the scheduler about reduced CPU capacity due to thermal. It is based on a value stored in a per-cpu 'thermal_pressure' variable. The online CPUs will get the new value there, while the offline won't. Unfortunately, when the CPU is back online, the value read from per-cpu variable might be wrong (stale data). This might affect the scheduler decisions, since it sees the CPU capacity differently than what is actually available.
Fix it by making sure that all online+offline CPUs would get the proper value in their per-cpu variable when thermal framework sets capping.
--- drivers/thermal/cpufreq_cooling.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/thermal/cpufreq_cooling.c +1 -1
@@ -478,7 +478,7 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, ret =freq_qos_update_request (&cpufreq_cdev->qos_req, frequency);if (ret >=0 ) { cpufreq_cdev->cpufreq_state = state; - cpus = cpufreq_cdev->policy->cpus; + cpus = cpufreq_cdev->policy->related_cpus; max_capacity =arch_scale_cpu_capacity (cpumask_first (cpus)); capacity = frequency * max_capacity; capacity /= cpufreq_cdev->policy->cpuinfo.max_freq;
Lukasz Luba
maintainerPATCH v4 2/3 sched/fair: Take thermal pressure into account while estimating energy
In reply to Lukasz LubaEnergy Aware Scheduling (EAS) needs to be able to predict the frequency requests made by the SchedUtil governor to properly estimate energy used in the future. It has to take into account CPUs utilization and forecast Performance Domain (PD) frequency. There is a corner case when the max allowed frequency might be reduced due to thermal. SchedUtil is aware of that reduced frequency, so it should be taken into account also in EAS estimations.
SchedUtil, as a CPUFreq governor, knows the maximum allowed frequency of a CPU, thanks to cpufreq_driver_resolve_freq() and internal clamping to 'policy::max'. SchedUtil is responsible to respect that upper limit while setting the frequency through CPUFreq drivers. This effective frequency is stored internally in 'sugov_policy::next_freq' and EAS has to predict that value.
In the existing code the raw value of arch_scale_cpu_capacity() is used for clamping the returned CPU utilization from effective_cpu_util(). This patch fixes issue with too big single CPU utilization, by introducing clamping to the allowed CPU capacity. The allowed CPU capacity is a CPU capacity reduced by thermal pressure raw value.
Thanks to knowledge about allowed CPU capacity, we don't get too big value for a single CPU utilization, which is then added to the util sum. The util sum is used as a source of information for estimating whole PD energy. To avoid wrong energy estimation in EAS (due to capped frequency), make sure that the calculation of util sum is aware of allowed CPU capacity.
This thermal pressure might be visible in scenarios where the CPUs are not heavily loaded, but some other component (like GPU) drastically reduced available power budget and increased the SoC temperature. Thus, we still use EAS for task placement and CPUs are not over-utilized.
--- kernel/sched/fair.c | 11 ++++++++--- 1 file changed, 8 insertions(+), 3 deletions(-)
kernel/sched/fair.c +8 -3
@@ -6527,8 +6527,11 @@ compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd)struct cpumask *pd_mask =perf_domain_span (pd);unsigned long cpu_cap =arch_scale_cpu_capacity (cpumask_first (pd_mask));unsigned long max_util =0 , sum_util =0 ; +unsigned long _cpu_cap = cpu_cap;int cpu; + _cpu_cap -=arch_scale_thermal_pressure (cpumask_first (pd_mask)); +/* * The capacity state of CPUs of the current rd can be driven by CPUs * of another rd if they belong to the same pd. So, account for the
@@ -6564,8 +6567,10 @@ compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd)* is already enough to scale the EM reported power * consumption at the (eventually clamped) cpu_capacity. */ - sum_util +=effective_cpu_util (cpu, util_running, cpu_cap, -ENERGY_UTIL ,NULL ); + cpu_util =effective_cpu_util (cpu, util_running, cpu_cap, +ENERGY_UTIL ,NULL ); + + sum_util +=min (cpu_util, _cpu_cap);/* * Performance domain frequency: utilization clamping
@@ -6576,7 +6581,7 @@ compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd)*/ cpu_util =effective_cpu_util (cpu, util_freq, cpu_cap,FREQUENCY_UTIL , tsk); - max_util =max (max_util, cpu_util); + max_util =max (max_util,min (cpu_util, _cpu_cap)); }return em_cpu_energy (pd->em_pd, max_util, sum_util);
Signature · 1 line
2.17.1
Dietmar Eggemann
reviewerRe: [PATCH v4 2/3] sched/fair: Take thermal pressure into account while estimating energy
Quoted 7 lines · Lukasz Luba
Energy Aware Scheduling (EAS) needs to be able to predict the frequency requests made by the SchedUtil governor to properly estimate energy used in the future. It has to take into account CPUs utilization and forecast Performance Domain (PD) frequency. There is a corner case when the max allowed frequency might be reduced due to thermal. SchedUtil is aware of that reduced frequency, so it should be taken into account also in EAS estimations.
It's important to highlight that this will only fix this issue between schedutil and EAS when it's due to thermal pressure (today only via CPU cooling). There are other places which could restrict policy->max via freq_qos_update_request() and EAS will be unaware of it.
Quoted 19 lines
SchedUtil, as a CPUFreq governor, knows the maximum allowed frequency of a CPU, thanks to
cpufreq_driver_resolve_freq()and internal clamping to 'policy::max'. SchedUtil is responsible to respect that upper limit while setting the frequency through CPUFreq drivers. This effective frequency is stored internally in 'sugov_policy::next_freq' and EAS has to predict that value.In the existing code the raw value of
arch_scale_cpu_capacity()is used for clamping the returned CPU utilization fromeffective_cpu_util(). This patch fixes issue with too big single CPU utilization, by introducing clamping to the allowed CPU capacity. The allowed CPU capacity is a CPU capacity reduced by thermal pressure raw value.Thanks to knowledge about allowed CPU capacity, we don't get too big value for a single CPU utilization, which is then added to the util sum. The util sum is used as a source of information for estimating whole PD energy. To avoid wrong energy estimation in EAS (due to capped frequency), make sure that the calculation of util sum is aware of allowed CPU capacity.
Quoted 4 lines
This thermal pressure might be visible in scenarios where the CPUs are not heavily loaded, but some other component (like GPU) drastically reduced available power budget and increased the SoC temperature. Thus, we still use EAS for task placement and CPUs are not over-utilized.
IMHO, this means that this is catered for the IPA governor then. I'm not sure if this would be beneficial when another thermal governor is used?
The mechanical side of the code would allow for such benefits, I just don't know if their CPU cooling device + thermal zone setups would cater for this?
Quoted 11 lines
Reviewed-by Vincent Guittot <[email protected]>Signed-off-by Lukasz Luba <[email protected]>--- kernel/sched/fair.c | 11 ++++++++--- 1 file changed, 8 insertions(+), 3 deletions(-)kernel/sched/fair.c +0
-0
kernel/sched/fair.c compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd) · line 6534
Quoted 8 lines
kernel/sched/fair.c +3
-0@@ -6527,8 +6527,11 @@ compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd)struct cpumask *pd_mask =perf_domain_span (pd);unsigned long cpu_cap =arch_scale_cpu_capacity (cpumask_first (pd_mask));unsigned long max_util =0 , sum_util =0 ; +unsigned long _cpu_cap = cpu_cap;int cpu; + _cpu_cap -=arch_scale_thermal_pressure (cpumask_first (pd_mask)); +
Maybe shorter?
struct cpumask *pd_mask = perf_domain_span(pd);
- unsigned long cpu_cap =
arch_scale_cpu_capacity(cpumask_first(pd_mask));
+ int cpu = cpumask_first(pd_mask);
+ unsigned long cpu_cap = arch_scale_cpu_capacity(cpu);
+ unsigned long _cpu_cap = cpu_cap - arch_scale_thermal_pressure(cpu);
unsigned long max_util = 0, sum_util = 0;- unsigned long _cpu_cap = cpu_cap;
- int cpu;
-
- _cpu_cap -= arch_scale_thermal_pressure(cpumask_first(pd_mask));
Quoted 17 lines
kernel/sched/fair.c +4
-2/* * The capacity state of CPUs of the current rd can be driven by CPUs * of another rd if they belong to the same pd. So, account for the @@ -6564,8 +6567,10 @@ compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd)* is already enough to scale the EM reported power * consumption at the (eventually clamped) cpu_capacity. */ - sum_util +=effective_cpu_util (cpu, util_running, cpu_cap, -ENERGY_UTIL ,NULL ); + cpu_util =effective_cpu_util (cpu, util_running, cpu_cap, +ENERGY_UTIL ,NULL ); + + sum_util +=min (cpu_util, _cpu_cap);/* * Performance domain frequency: utilization clamping
kernel/sched/fair.c compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd) · line 6587
Quoted 8 lines
kernel/sched/fair.c +1
-1@@ -6576,7 +6581,7 @@ compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd)*/ cpu_util =effective_cpu_util (cpu, util_freq, cpu_cap,FREQUENCY_UTIL , tsk); - max_util =max (max_util, cpu_util); + max_util =max (max_util,min (cpu_util, _cpu_cap)); }return em_cpu_energy (pd->em_pd, max_util, sum_util);
There is IPA specific code in cpufreq_set_cur_state() -> get_state_freq() which accesses the EM:
...
return cpufreq_cdev->em->table[idx].frequency;
...Has it been discussed that the per-PD max (allowed) CPU capacity (1) could be stored in the EM from there so that code like the EAS wakeup code (compute_energy()) could retrieve this information from the EM? And there wouldn't be any need to pass (1) into the EM (like now via em_cpu_energy()).
This would be signalling within the EM compared to external signalling via CPU cooling -> thermal pressure <- EAS wakeup -> EM.
Lukasz Luba
maintainerRe: [PATCH v4 2/3] sched/fair: Take thermal pressure into account while estimating energy
Quoted 9 lines · Dietmar Eggemann
Quoted 7 lines · Lukasz Luba
Energy Aware Scheduling (EAS) needs to be able to predict the frequency requests made by the SchedUtil governor to properly estimate energy used in the future. It has to take into account CPUs utilization and forecast Performance Domain (PD) frequency. There is a corner case when the max allowed frequency might be reduced due to thermal. SchedUtil is aware of that reduced frequency, so it should be taken into account also in EAS estimations.
Quoted 4 lines
It's important to highlight that this will only fix this issue between schedutil and EAS when it's due to
thermal pressure(today only via CPU cooling). There are other places which could restrictpolicy->maxviafreq_qos_update_request()and EAS will be unaware of it.
True, but for this I have some other plans.
Quoted 20 lines
Quoted 20 lines
SchedUtil, as a CPUFreq governor, knows the maximum allowed frequency of a CPU, thanks to
cpufreq_driver_resolve_freq()and internal clamping to 'policy::max'. SchedUtil is responsible to respect that upper limit while setting the frequency through CPUFreq drivers. This effective frequency is stored internally in 'sugov_policy::next_freq' and EAS has to predict that value.In the existing code the raw value of
arch_scale_cpu_capacity()is used for clamping the returned CPU utilization fromeffective_cpu_util(). This patch fixes issue with too big single CPU utilization, by introducing clamping to the allowed CPU capacity. The allowed CPU capacity is a CPU capacity reduced by thermal pressure raw value.Thanks to knowledge about allowed CPU capacity, we don't get too big value for a single CPU utilization, which is then added to the util sum. The util sum is used as a source of information for estimating whole PD energy. To avoid wrong energy estimation in EAS (due to capped frequency), make sure that the calculation of util sum is aware of allowed CPU capacity.
Quoted 7 lines
Quoted 4 lines
This thermal pressure might be visible in scenarios where the CPUs are not heavily loaded, but some other component (like GPU) drastically reduced available power budget and increased the SoC temperature. Thus, we still use EAS for task placement and CPUs are not over-utilized.
IMHO, this means that this is catered for the IPA governor then. I'm not sure if this would be beneficial when another thermal governor is used?
Yes, it will be, the cpufreq_set_cur_state() is called by thermal exported function:thermal_cdev_update()
__thermal_cdev_update()
thermal_cdev_set_cur_state()
cdev->ops->set_cur_state(cdev, target)So it can be called not only by IPA. All governors call it, because that's the default mechanism.
Quoted 4 lines
The mechanical side of the code would allow for such benefits, I just don't know if their CPU cooling device + thermal zone setups would cater for this?
Yes, it's possible. Even for custom vendor governors (modified clones of IPA)
Quoted 26 lines
Quoted 12 lines
Reviewed-by Vincent Guittot <[email protected]>Signed-off-by Lukasz Luba <[email protected]>--- kernel/sched/fair.c | 11 ++++++++--- 1 file changed, 8 insertions(+), 3 deletions(-)kernel/sched/fair.c +0
-0kernel/sched/fair.c compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd) · line 6534
Quoted 8 lines
kernel/sched/fair.c +3
-0@@ -6527,8 +6527,11 @@ compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd)struct cpumask *pd_mask =perf_domain_span (pd);unsigned long cpu_cap =arch_scale_cpu_capacity (cpumask_first (pd_mask));unsigned long max_util =0 , sum_util =0 ; +unsigned long _cpu_cap = cpu_cap;int cpu; + _cpu_cap -=arch_scale_thermal_pressure (cpumask_first (pd_mask)); +Maybe shorter?
struct cpumask *pd_mask = perf_domain_span(pd);- unsigned long
cpu_cap=
arch_scale_cpu_capacity(cpumask_first(pd_mask));
Review
Quoted 8 lines
(quoted diff) +3
-4+ int cpu = cpumask_first(pd_mask); + unsigned long cpu_cap = arch_scale_cpu_capacity(cpu); + unsigned long _cpu_cap = cpu_cap - arch_scale_thermal_pressure(cpu); unsigned long max_util = 0, sum_util = 0; - unsigned long _cpu_cap = cpu_cap; - int cpu; - - _cpu_cap -= arch_scale_thermal_pressure(cpumask_first(pd_mask));
Could be, but still, the definitions should be sorted from longest on top, to shortest at the bottom. I wanted to avoid modifying too many lines with this simple patch.
Quoted 30 lines
Quoted 18 lines
kernel/sched/fair.c +4
-2/* * The capacity state of CPUs of the current rd can be driven by CPUs * of another rd if they belong to the same pd. So, account for the @@ -6564,8 +6567,10 @@ compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd)* is already enough to scale the EM reported power * consumption at the (eventually clamped) cpu_capacity. */ - sum_util +=effective_cpu_util (cpu, util_running, cpu_cap, -ENERGY_UTIL ,NULL ); + cpu_util =effective_cpu_util (cpu, util_running, cpu_cap, +ENERGY_UTIL ,NULL ); + + sum_util +=min (cpu_util, _cpu_cap);/* * Performance domain frequency: utilization clamping kernel/sched/fair.c compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd) · line 6587
Quoted 8 lines
kernel/sched/fair.c +1
-1@@ -6576,7 +6581,7 @@ compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd)*/ cpu_util =effective_cpu_util (cpu, util_freq, cpu_cap,FREQUENCY_UTIL , tsk); - max_util =max (max_util, cpu_util); + max_util =max (max_util,min (cpu_util, _cpu_cap)); }return em_cpu_energy (pd->em_pd, max_util, sum_util);There is IPA specific code in
cpufreq_set_cur_state()->get_state_freq()which accesses the EM:
Quoted 7 lines
... return cpufreq_cdev->em->table[idx].frequency; ...Has it been discussed that the
per-PD max (allowed) CPU capacity(1) could be stored in the EM from there so that code like the EAS wakeup code (compute_energy()) could retrieve this information from the EM?
No, we haven't think about this approach in these patch sets. The EM structure given to the cpufreq_cooling device and stored in:cpufreq_cdev->em should not be modified. There are a few places which receive the EM, but they all should not touch it. For those clients it's a read-only data structure.
Quoted 5 lines
And there wouldn't be any need to pass (1) into the EM (like now via
em_cpu_energy()).
This would be signalling within the EM compared to external signalling viaCPU cooling -> thermal pressure <- EAS wakeup -> EM.
I see what you mean, but this might cause some issues in the design (per-cpu scmi cpu perf control). Let's use this EM pointer gently ;)
Re: [PATCH v4 2/3] sched/fair: Take thermal pressure into account while estimating energy
Quoted 3 lines · Lukasz Luba
Quoted 1 line · Dietmar Eggemann
On 14/06/2021 21:11, Lukasz Luba wrote:
[...]
Quoted 6 lines
Quoted 4 lines
It's important to highlight that this will only fix this issue between schedutil and EAS when it's due to
thermal pressure(today only via CPU cooling). There are other places which could restrictpolicy->maxviafreq_qos_update_request()and EAS will be unaware of it.True, but for this I have some other plans.
As long as people are aware of the fact that this was developed to be beneficial for EAS - IPA integration, I'm fine with this.
[...]
Quoted 10 lines
Quoted 2 lines
IMHO, this means that this is catered for the IPA governor then. I'm not sure if this would be beneficial when another thermal governor is used?
Yes, it will be, the
cpufreq_set_cur_state()is called by thermal exported function:thermal_cdev_update()
__thermal_cdev_update()thermal_cdev_set_cur_state()cdev->ops->set_cur_state(cdev, target)
Quoted 2 lines
So it can be called not only by IPA. All governors call it, because that's the default mechanism.
True, but I'm still not convinced that it is useful outside EAS - IPA.
Quoted 6 lines
Quoted 3 lines
The mechanical side of the code would allow for such benefits, I just don't know if their CPU cooling device + thermal zone setups would cater for this?
Yes, it's possible. Even for custom vendor governors (modified clones of IPA)
Let's stick to mainline here ;-) It's complicated enough ...
[...]
Quoted 15 lines
Quoted 14 lines
Maybe shorter?
struct cpumask
*pd_mask=perf_domain_span(pd);
- unsigned longcpu_cap= arch_scale_cpu_capacity(cpumask_first(pd_mask));
+ int cpu =cpumask_first(pd_mask);
+ unsigned longcpu_cap=arch_scale_cpu_capacity(cpu); + unsigned long_cpu_cap=cpu_cap-arch_scale_thermal_pressure(cpu);
unsigned longmax_util= 0,sum_util= 0;
- unsigned long_cpu_cap=cpu_cap;
- int cpu;
-
-_cpu_cap-= arch_scale_thermal_pressure(cpumask_first(pd_mask));
Quoted 3 lines
Could be, but still, the definitions should be sorted from longest on top, to shortest at the bottom. I wanted to avoid modifying too many lines with this simple patch.
Only if there are no dependencies, but here we have already cpu_cap -> pd_mask. OK, not a big deal.
[...]
Quoted 17 lines
Quoted 10 lines
There is IPA specific code in
cpufreq_set_cur_state()->get_state_freq()which accesses the EM:...
return cpufreq_cdev->em->table[idx].frequency;
...Has it been discussed that the
per-PD max (allowed) CPU capacity(1) could be stored in the EM from there so that code like the EAS wakeup code (compute_energy()) could retrieve this information from the EM?No, we haven't think about this approach in these patch sets. The EM structure given to the
cpufreq_coolingdevice and stored in:cpufreq_cdev->emshould not be modified. There are a few places which receive the EM, but they all should not touch it. For those clients it's a read-only data structure.
Quoted 7 lines
Quoted 4 lines
And there wouldn't be any need to pass (1) into the EM (like now via
em_cpu_energy()).
This would be signalling within the EM compared to external signalling viaCPU cooling -> thermal pressure <- EAS wakeup -> EM.I see what you mean, but this might cause some issues in the design (per-cpu scmi cpu perf control). Let's use this EM pointer gently ;)
OK, with the requirement that clients see the EM as ro:
Lukasz Luba
maintainerRe: [PATCH v4 2/3] sched/fair: Take thermal pressure into account while estimating energy
Quoted 12 lines · Dietmar Eggemann
Quoted 3 lines · Lukasz Luba
Quoted 1 line · Dietmar Eggemann
On 14/06/2021 21:11, Lukasz Luba wrote:
[...]
Quoted 5 lines
Quoted 4 lines
It's important to highlight that this will only fix this issue between schedutil and EAS when it's due to
thermal pressure(today only via CPU cooling). There are other places which could restrictpolicy->maxviafreq_qos_update_request()and EAS will be unaware of it.
Quoted 4 lines
Quoted 1 line
True, but for this I have some other plans.
As long as people are aware of the fact that this was developed to be beneficial for
EAS - IPAintegration, I'm fine with this.
Good. I had in mind that I will have to do some re-work on this thermal pressure code in the cpufreq cooling, to satisfy our roadmap goals...
Quoted 13 lines
[...]
Quoted 10 lines
Quoted 2 lines
IMHO, this means that this is catered for the IPA governor then. I'm not sure if this would be beneficial when another thermal governor is used?
Yes, it will be, the
cpufreq_set_cur_state()is called by thermal exported function:thermal_cdev_update()
__thermal_cdev_update()thermal_cdev_set_cur_state()cdev->ops->set_cur_state(cdev, target)
Quoted 4 lines
Quoted 2 lines
So it can be called not only by IPA. All governors call it, because that's the default mechanism.
True, but I'm still not convinced that it is useful outside
EAS - IPA.
It is. So in mainline thermal there is another governor: fair_share [1], which uses 'weights' to split the cooling effort across cooling devices in the thermal zone. That governor would manage CPUs and GPU and set throttling like IPA.
Quoted 9 lines
Quoted 7 lines
Quoted 4 lines
The mechanical side of the code would allow for such benefits, I just don't know if their CPU cooling device + thermal zone setups would cater for this?
Yes, it's possible. Even for custom vendor governors (modified clones of IPA)
Let's stick to mainline here ;-) It's complicated enough ...
I agree, so there isn't only IPA in mainline.
Quoted 18 lines
[...]
Quoted 15 lines
Quoted 14 lines
Maybe shorter?
struct cpumask
*pd_mask=perf_domain_span(pd);
- unsigned longcpu_cap= arch_scale_cpu_capacity(cpumask_first(pd_mask));
+ int cpu =cpumask_first(pd_mask);
+ unsigned longcpu_cap=arch_scale_cpu_capacity(cpu); + unsigned long_cpu_cap=cpu_cap-arch_scale_thermal_pressure(cpu);
unsigned longmax_util= 0,sum_util= 0;
- unsigned long_cpu_cap=cpu_cap;
- int cpu;
-
-_cpu_cap-= arch_scale_thermal_pressure(cpumask_first(pd_mask));
Quoted 6 lines
Quoted 3 lines
Could be, but still, the definitions should be sorted from longest on top, to shortest at the bottom. I wanted to avoid modifying too many lines with this simple patch.
Only if there are no dependencies, but here we have already
cpu_cap -> pd_mask. OK, not a big deal.
True, those dependencies are tricky to sort them properly, so I coded it this way.
[snip]
Quoted 7 lines
Quoted 2 lines
I see what you mean, but this might cause some issues in the design (per-cpu scmi cpu perf control). Let's use this EM pointer gently ;)
OK, with the requirement that clients see the EM as ro:
Reviewed-by Dietmar Eggemann <[email protected]>
Thank you Dietmar for the review!
Regards,
Lukasz
[1] https://elixir.bootlin.com/linux/v5.13-rc6/source/drivers/thermal/gov_fair_share.c#L111
Vincent Guittot
maintainerRe: [PATCH v4 2/3] sched/fair: Take thermal pressure into account while estimating energy
In reply to Dietmar EggemannQuoted 13 lines · Dietmar Eggemann
Quoted 3 lines · Lukasz Luba
Quoted 1 line · Dietmar Eggemann
On 14/06/2021 21:11, Lukasz Luba wrote:
[...]
Quoted 5 lines
Quoted 4 lines
It's important to highlight that this will only fix this issue between schedutil and EAS when it's due to
thermal pressure(today only via CPU cooling). There are other places which could restrictpolicy->maxviafreq_qos_update_request()and EAS will be unaware of it.
Quoted 4 lines
Quoted 1 line
True, but for this I have some other plans.
As long as people are aware of the fact that this was developed to be beneficial for
EAS - IPAintegration, I'm fine with this.
I don't think it's only for EAS - IPA. Thermal_pressure can be used by HW throttling like here:
https://lkml.org/lkml/2021/6/8/1791
EAS is involved but not IPA
Quoted 81 lines
[...]
Quoted 7 lines
Quoted 2 lines
IMHO, this means that this is catered for the IPA governor then. I'm not sure if this would be beneficial when another thermal governor is used?
Yes, it will be, the
cpufreq_set_cur_state()is called by thermal exported function:thermal_cdev_update()
__thermal_cdev_update()Quoted 5 lines
thermal_cdev_set_cur_state() cdev->ops->set_cur_state(cdev, target)So it can be called not only by IPA. All governors call it, because that's the default mechanism.
True, but I'm still not convinced that it is useful outside
EAS - IPA.Quoted 6 lines
Quoted 3 lines
The mechanical side of the code would allow for such benefits, I just don't know if their CPU cooling device + thermal zone setups would cater for this?
Yes, it's possible. Even for custom vendor governors (modified clones of IPA)
Let's stick to mainline here ;-) It's complicated enough ...
[...]
Quoted 15 lines
Quoted 10 lines
Maybe shorter?
struct cpumask *pd_mask = perf_domain_span(pd);- unsigned long
cpu_cap=
arch_scale_cpu_capacity(cpumask_first(pd_mask));(quoted diff) +3
-0+ int cpu = cpumask_first(pd_mask); + unsigned long cpu_cap = arch_scale_cpu_capacity(cpu); + unsigned long _cpu_cap = cpu_cap -arch_scale_thermal_pressure(cpu); unsigned long max_util = 0, sum_util = 0;Review
Quoted 4 lines
(quoted diff) +0
-4- unsigned long _cpu_cap = cpu_cap; - int cpu; - - _cpu_cap -= arch_scale_thermal_pressure(cpumask_first(pd_mask));Quoted 3 lines
Could be, but still, the definitions should be sorted from longest on top, to shortest at the bottom. I wanted to avoid modifying too many lines with this simple patch.
Only if there are no dependencies, but here we have already
cpu_cap -> pd_mask. OK, not a big deal.[...]
Quoted 17 lines
Quoted 10 lines
There is IPA specific code in
cpufreq_set_cur_state()->get_state_freq()which accesses the EM:... return cpufreq_cdev->em->table[idx].frequency; ...Has it been discussed that the
per-PD max (allowed) CPU capacity(1) could be stored in the EM from there so that code like the EAS wakeup code (compute_energy()) could retrieve this information from the EM?No, we haven't think about this approach in these patch sets. The EM structure given to the
cpufreq_coolingdevice and stored in:cpufreq_cdev->emshould not be modified. There are a few places which receive the EM, but they all should not touch it. For those clients it's a read-only data structure.Quoted 7 lines
Quoted 4 lines
And there wouldn't be any need to pass (1) into the EM (like now via
em_cpu_energy()).
This would be signalling within the EM compared to external signalling viaCPU cooling -> thermal pressure <- EAS wakeup -> EM.I see what you mean, but this might cause some issues in the design (per-cpu scmi cpu perf control). Let's use this EM pointer gently ;)
OK, with the requirement that clients see the EM as ro:
Reviewed-by Dietmar Eggemann <[email protected]>
Lukasz Luba
maintainerRe: [PATCH v4 2/3] sched/fair: Take thermal pressure into account while estimating energy
Quoted 16 lines · Vincent Guittot
Quoted 15 lines · Dietmar Eggemann
Quoted 3 lines · Lukasz Luba
Quoted 1 line · Dietmar Eggemann
On 14/06/2021 21:11, Lukasz Luba wrote:
[...]
Quoted 6 lines
Quoted 4 lines
It's important to highlight that this will only fix this issue between schedutil and EAS when it's due to
thermal pressure(today only via CPU cooling). There are other places which could restrictpolicy->maxviafreq_qos_update_request()and EAS will be unaware of it.True, but for this I have some other plans.
Quoted 8 lines
Quoted 2 lines
As long as people are aware of the fact that this was developed to be beneficial for
EAS - IPAintegration, I'm fine with this.I don't think it's only for EAS - IPA.
Thermal_pressurecan be used by HW throttling like here:
https://lkml.org/lkml/2021/6/8/1791EAS is involved but not IPA
Thank you Vincent for pointing to Thara's patches. Indeed, this is a good example. We will have to provide similar for our SCMI perf notifications - these are the plans that I've mentioned. In both new examples, the IPA (or other governors) won't be even involved.
[tip: sched/core] sched/fair: Take thermal pressure into account while estimating energy
In reply to Lukasz LubaThe following commit has been merged into the sched/core branch of tip:
The following commit has been merged into the sched/core branch of tip:
Commit-ID: 489f16459e0008c7a5c4c5af34bd80898aa82c2d Gitweb: https://git.kernel.org/tip/489f16459e0008c7a5c4c5af34bd80898aa82c2d Author: Lukasz Luba <[email protected]> AuthorDate: Mon, 14 Jun 2021 20:11:28 +01:00 Committer: Peter Zijlstra <[email protected]> CommitterDate: Thu, 17 Jun 2021 14:11:43 +02:00
sched/fair: Take thermal pressure into account while estimating energy
Energy Aware Scheduling (EAS) needs to be able to predict the frequency requests made by the SchedUtil governor to properly estimate energy used in the future. It has to take into account CPUs utilization and forecast Performance Domain (PD) frequency. There is a corner case when the max allowed frequency might be reduced due to thermal. SchedUtil is aware of that reduced frequency, so it should be taken into account also in EAS estimations.
SchedUtil, as a CPUFreq governor, knows the maximum allowed frequency of a CPU, thanks to cpufreq_driver_resolve_freq() and internal clamping to 'policy::max'. SchedUtil is responsible to respect that upper limit while setting the frequency through CPUFreq drivers. This effective frequency is stored internally in 'sugov_policy::next_freq' and EAS has to predict that value.
In the existing code the raw value of arch_scale_cpu_capacity() is used for clamping the returned CPU utilization from effective_cpu_util(). This patch fixes issue with too big single CPU utilization, by introducing clamping to the allowed CPU capacity. The allowed CPU capacity is a CPU capacity reduced by thermal pressure raw value.
Thanks to knowledge about allowed CPU capacity, we don't get too big value for a single CPU utilization, which is then added to the util sum. The util sum is used as a source of information for estimating whole PD energy. To avoid wrong energy estimation in EAS (due to capped frequency), make sure that the calculation of util sum is aware of allowed CPU capacity.
This thermal pressure might be visible in scenarios where the CPUs are not heavily loaded, but some other component (like GPU) drastically reduced available power budget and increased the SoC temperature. Thus, we still use EAS for task placement and CPUs are not over-utilized.
--- kernel/sched/fair.c | 11 ++++++++--- 1 file changed, 8 insertions(+), 3 deletions(-)
kernel/sched/fair.c +8 -3
@@ -6535,8 +6535,11 @@ compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd)struct cpumask *pd_mask =perf_domain_span (pd);unsigned long cpu_cap =arch_scale_cpu_capacity (cpumask_first (pd_mask));unsigned long max_util =0 , sum_util =0 ; +unsigned long _cpu_cap = cpu_cap;int cpu; + _cpu_cap -=arch_scale_thermal_pressure (cpumask_first (pd_mask)); +/* * The capacity state of CPUs of the current rd can be driven by CPUs * of another rd if they belong to the same pd. So, account for the
@@ -6572,8 +6575,10 @@ compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd)* is already enough to scale the EM reported power * consumption at the (eventually clamped) cpu_capacity. */ - sum_util +=effective_cpu_util (cpu, util_running, cpu_cap, -ENERGY_UTIL ,NULL ); + cpu_util =effective_cpu_util (cpu, util_running, cpu_cap, +ENERGY_UTIL ,NULL ); + + sum_util +=min (cpu_util, _cpu_cap);/* * Performance domain frequency: utilization clamping
@@ -6584,7 +6589,7 @@ compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd)*/ cpu_util =effective_cpu_util (cpu, util_freq, cpu_cap,FREQUENCY_UTIL , tsk); - max_util =max (max_util, cpu_util); + max_util =max (max_util,min (cpu_util, _cpu_cap)); }return em_cpu_energy (pd->em_pd, max_util, sum_util);
Lukasz Luba
maintainerPATCH v4 3/3 sched/cpufreq: Consider reduced CPU capacity in energy calculation
In reply to Lukasz LubaEnergy Aware Scheduling (EAS) needs to predict the decisions made by SchedUtil. The map_util_freq() exists to do that.
There are corner cases where the max allowed frequency might be reduced (due to thermal). SchedUtil as a CPUFreq governor, is aware of that but EAS is not. This patch aims to address it.
SchedUtil stores the maximum allowed frequency in 'sugov_policy::next_freq' field. EAS has to predict that value, which is the real used frequency. That value is made after a call to cpufreq_driver_resolve_freq() which clamps to the CPUFreq policy limits. In the existing code EAS is not able to predict that real frequency. This leads to energy estimation errors.
To avoid wrong energy estimation in EAS (due to frequency miss prediction) make sure that the step which calculates Performance Domain frequency, is also aware of the allowed CPU capacity.
Furthermore, modify map_util_freq() to not extend the frequency value. Instead, use map_util_perf() to extend the util value in both places:
SchedUtil and EAS, but for EAS clamp it to max allowed CPU capacity. In the end, we achieve the same desirable behavior for both subsystems and alignment in regards to the real CPU frequency.
--- include/linux/energy_model.h | 16 +++++++++++++--- include/linux/sched/cpufreq.h | 2 +- kernel/sched/cpufreq_schedutil.c | 1 + kernel/sched/fair.c | 2 +- 4 files changed, 16 insertions(+), 5 deletions(-)
include/linux/energy_model.h +13 -3
@@ -91,6 +91,8 @@ void em_dev_unregister_perf_domain(struct device *dev);* @pd : performance domain for which energy has to be estimated * @max_util : highest utilization among CPUs of the domain * @sum_util : sum of the utilization of all CPUs in the domain +* @allowed_cpu_cap : maximum allowed CPU capacity for the @pd, which +might reflect reduced frequency (due to thermal) * * This function must be used only for CPU devices. There is no validation, * i.e. if the EM is a CPU type and has cpumask allocated. It is called from
@@ -100,7 +102,8 @@ void em_dev_unregister_perf_domain(struct device *dev);* a capacity state satisfying the max utilization of the domain. */ static inline unsigned long em_cpu_energy (struct em_perf_domain *pd, -unsigned long max_util,unsigned long sum_util) +unsigned long max_util,unsigned long sum_util, +unsigned long allowed_cpu_cap) {unsigned long freq, scale_cpu;struct em_perf_state *ps;
@@ -112,11 +115,17 @@ static inline unsigned long em_cpu_energy(struct em_perf_domain *pd,/* * In order to predict the performance state, map the utilization of * the most utilized CPU of the performance domain to a requested -* frequency, like schedutil. +* frequency, like schedutil. Take also into account that the real +* frequency might be set lower (due to thermal capping). Thus, clamp +* max utilization to the allowed CPU capacity before calculating +* effective frequency. */ cpu =cpumask_first (to_cpumask (pd->cpus)); scale_cpu =arch_scale_cpu_capacity (cpu); ps = &pd->table[pd->nr_perf_states -1 ]; + + max_util =map_util_perf (max_util); + max_util =min (max_util, allowed_cpu_cap); freq =map_util_freq (max_util, ps->frequency, scale_cpu);/*
@@ -209,7 +218,8 @@ static inline struct em_perf_domain *em_pd_get(struct device *dev)return NULL ; }static inline unsigned long em_cpu_energy (struct em_perf_domain *pd, -unsigned long max_util,unsigned long sum_util) +unsigned long max_util,unsigned long sum_util, +unsigned long allowed_cpu_cap) {return 0 ; }
include/linux/sched/cpufreq.h +1 -1
@@ -26,7 +26,7 @@ bool cpufreq_this_cpu_can_update(struct cpufreq_policy *policy);static inline unsigned long map_util_freq (unsigned long util,unsigned long freq,unsigned long cap) { -return (freq + (freq >>2 )) * util / cap; +return freq * util / cap; }static inline unsigned long map_util_perf (unsigned long util)
kernel/sched/cpufreq_schedutil.c +1 -0
@@ -151,6 +151,7 @@ static unsigned int get_next_freq(struct sugov_policy *sg_policy,unsigned int freq =arch_scale_freq_invariant () ? policy->cpuinfo.max_freq : policy->cur; + util =map_util_perf (util); freq =map_util_freq (util, freq, max);if (freq == sg_policy->cached_raw_freq && !sg_policy->need_freq_update)
kernel/sched/fair.c +1 -1
@@ -6584,7 +6584,7 @@ compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd) max_util =max (max_util,min (cpu_util, _cpu_cap)); } -return em_cpu_energy (pd->em_pd, max_util, sum_util); +return em_cpu_energy (pd->em_pd, max_util, sum_util, _cpu_cap); }/*
Signature · 1 line
2.17.1
[tip: sched/core] sched/cpufreq: Consider reduced CPU capacity in energy calculation
The following commit has been merged into the sched/core branch of tip:
The following commit has been merged into the sched/core branch of tip:
Commit-ID: 8f1b971b4750e83e8fbd2f91a9efd4a38ad0ae51 Gitweb: https://git.kernel.org/tip/8f1b971b4750e83e8fbd2f91a9efd4a38ad0ae51 Author: Lukasz Luba <[email protected]> AuthorDate: Mon, 14 Jun 2021 20:12:38 +01:00 Committer: Peter Zijlstra <[email protected]> CommitterDate: Thu, 17 Jun 2021 14:11:43 +02:00
sched/cpufreq: Consider reduced CPU capacity in energy calculation
Energy Aware Scheduling (EAS) needs to predict the decisions made by SchedUtil. The map_util_freq() exists to do that.
There are corner cases where the max allowed frequency might be reduced (due to thermal). SchedUtil as a CPUFreq governor, is aware of that but EAS is not. This patch aims to address it.
SchedUtil stores the maximum allowed frequency in 'sugov_policy::next_freq' field. EAS has to predict that value, which is the real used frequency. That value is made after a call to cpufreq_driver_resolve_freq() which clamps to the CPUFreq policy limits. In the existing code EAS is not able to predict that real frequency. This leads to energy estimation errors.
To avoid wrong energy estimation in EAS (due to frequency miss prediction) make sure that the step which calculates Performance Domain frequency, is also aware of the allowed CPU capacity.
Furthermore, modify map_util_freq() to not extend the frequency value. Instead, use map_util_perf() to extend the util value in both places:
SchedUtil and EAS, but for EAS clamp it to max allowed CPU capacity. In the end, we achieve the same desirable behavior for both subsystems and alignment in regards to the real CPU frequency.
--- include/linux/energy_model.h | 16 +++++++++++++--- include/linux/sched/cpufreq.h | 2 +- kernel/sched/cpufreq_schedutil.c | 1 + kernel/sched/fair.c | 2 +- 4 files changed, 16 insertions(+), 5 deletions(-)
include/linux/energy_model.h +13 -3
@@ -91,6 +91,8 @@ void em_dev_unregister_perf_domain(struct device *dev);* @pd : performance domain for which energy has to be estimated * @max_util : highest utilization among CPUs of the domain * @sum_util : sum of the utilization of all CPUs in the domain +* @allowed_cpu_cap : maximum allowed CPU capacity for the @pd, which +might reflect reduced frequency (due to thermal) * * This function must be used only for CPU devices. There is no validation, * i.e. if the EM is a CPU type and has cpumask allocated. It is called from
@@ -100,7 +102,8 @@ void em_dev_unregister_perf_domain(struct device *dev);* a capacity state satisfying the max utilization of the domain. */ static inline unsigned long em_cpu_energy (struct em_perf_domain *pd, -unsigned long max_util,unsigned long sum_util) +unsigned long max_util,unsigned long sum_util, +unsigned long allowed_cpu_cap) {unsigned long freq, scale_cpu;struct em_perf_state *ps;
@@ -112,11 +115,17 @@ static inline unsigned long em_cpu_energy(struct em_perf_domain *pd,/* * In order to predict the performance state, map the utilization of * the most utilized CPU of the performance domain to a requested -* frequency, like schedutil. +* frequency, like schedutil. Take also into account that the real +* frequency might be set lower (due to thermal capping). Thus, clamp +* max utilization to the allowed CPU capacity before calculating +* effective frequency. */ cpu =cpumask_first (to_cpumask (pd->cpus)); scale_cpu =arch_scale_cpu_capacity (cpu); ps = &pd->table[pd->nr_perf_states -1 ]; + + max_util =map_util_perf (max_util); + max_util =min (max_util, allowed_cpu_cap); freq =map_util_freq (max_util, ps->frequency, scale_cpu);/*
@@ -209,7 +218,8 @@ static inline struct em_perf_domain *em_pd_get(struct device *dev)return NULL ; }static inline unsigned long em_cpu_energy (struct em_perf_domain *pd, -unsigned long max_util,unsigned long sum_util) +unsigned long max_util,unsigned long sum_util, +unsigned long allowed_cpu_cap) {return 0 ; }
include/linux/sched/cpufreq.h +1 -1
@@ -26,7 +26,7 @@ bool cpufreq_this_cpu_can_update(struct cpufreq_policy *policy);static inline unsigned long map_util_freq (unsigned long util,unsigned long freq,unsigned long cap) { -return (freq + (freq >>2 )) * util / cap; +return freq * util / cap; }static inline unsigned long map_util_perf (unsigned long util)
kernel/sched/cpufreq_schedutil.c +1 -0
@@ -151,6 +151,7 @@ static unsigned int get_next_freq(struct sugov_policy *sg_policy,unsigned int freq =arch_scale_freq_invariant () ? policy->cpuinfo.max_freq : policy->cur; + util =map_util_perf (util); freq =map_util_freq (util, freq, max);if (freq == sg_policy->cached_raw_freq && !sg_policy->need_freq_update)
kernel/sched/fair.c +1 -1
@@ -6592,7 +6592,7 @@ compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd) max_util =max (max_util,min (cpu_util, _cpu_cap)); } -return em_cpu_energy (pd->em_pd, max_util, sum_util); +return em_cpu_energy (pd->em_pd, max_util, sum_util, _cpu_cap); }/*
Lukasz Luba
maintainerHi Peter,
Quoted 44 lines · Lukasz Luba
Hi all,
The patch set v4 aims to add knowledge about reduced CPU capacity into the Energy Model (EM) and Energy Aware Scheduler (EAS). Currently the issue is that SchedUtil CPU frequency and EM frequency are not aligned, when there is a CPU thermal capping. This causes an estimation error. This patch set provides the information about allowed CPU capacity into the EM (thanks to thermal pressure information). This improves the energy estimation. More info about this mechanism can be found in the patches description.
Changelog:
v4:
- removed local variable and improved description in patch 2/3
- added Reviewed-by from Vincent for patch 2/3
- added Acked-by from Viresh for patch 1/3
v3 [3]:
- switched to 'raw' per-cpu thermal pressure instead of thermal pressure geometric series signal, since it more suited for purpose of this use case: predicting SchedUtil frequency (Vincent, Dietmar)
- added more comment in the patch 2/3 header for use case when thermal capping might be applied even the CPUs are not over-utilized (Dietmar)
- added ACK tag from Rafael for SchedUtil part
- added a fix patch for offline CPUs incpufreq_coolingand per-cputhermal_pressuremissing update
v2 [2]:
- clamp the returned value fromeffective_cpu_util()and avoid irq util scaling issues (Quentin)
v1 is available at [1]Regards,
Lukasz[1] https://lore.kernel.org/linux-pm/[email protected]/
[2] https://lore.kernel.org/lkml/[email protected]/
[3] https://lore.kernel.org/lkml/[email protected]/Lukasz Luba (3):
thermal:cpufreq_cooling: Update also offline CPUs per-cpu
thermal_pressure
sched/fair: Take thermal pressure into account while estimating energy sched/cpufreq: Consider reduced CPU capacity in energy calculation
Quoted 7 lines
drivers/thermal/cpufreq_cooling.c | 2 +- include/linux/energy_model.h | 16 +++++++++++++--- include/linux/sched/cpufreq.h | 2 +- kernel/sched/cpufreq_schedutil.c | 1 + kernel/sched/fair.c | 13 +++++++++---- 5 files changed, 25 insertions(+), 9 deletions(-)
Could you take these 3 patches via your tree, please? I'm asking you because the fair.c has most changes (apart from energy_model.h) and the patches got ACKs from Rafael and Viresh. The patch which touches fair.c got Reviewed-by Vincent Guittot. I have address all the comment, thus, IMHO it could fly now.
Please let me know if you like me to re-base on top of some of your branches.
Regards,
Lukasz