Skip to contentSkip to conversation

arm64: dts: rockchip: Add idle cooling devices

PATCH Applied Daniel Lezcano 2 participants 4 messages Oct 1, 2021 – Oct 20, 2021

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH 1/1 arm64: dts: rockchip: Add idle cooling devices

The thermal framework accepts now the cpu idle cooling device as an alternative when the cpufreq cooling device fails.

Add the node in the DT so the cooling devices will be present and the platforms can extend the thermal zone definition to add them.

---
 arch/arm64/boot/dts/rockchip/rk3399.dtsi | 10 ++++++++++
 1 file changed, 10 insertions(+)
arch/arm64/boot/dts/rockchip/rk3399.dtsi +10 -0
index 3871c7fd83b0..9ac232ffd284 100644
@@ -124,6 +124,11 @@ cpu_b0: cpu@100 {
 			#cooling-cells = <2>; /* min followed by max */
 			dynamic-power-coefficient = <436>;
 			cpu-idle-states = <&CPU_SLEEP &CLUSTER_SLEEP>;
+			thermal-idle {
+				#cooling-cells = <2>;
+				duration-us = <10000>;
+				exit-latency-us = <500>;
+			};
 		};
 
 		cpu_b1: cpu@101 {
@@ -136,6 +141,11 @@ cpu_b1: cpu@101 {
 			#cooling-cells = <2>; /* min followed by max */
 			dynamic-power-coefficient = <436>;
 			cpu-idle-states = <&CPU_SLEEP &CLUSTER_SLEEP>;
+			thermal-idle {
+				#cooling-cells = <2>;
+				duration-us = <10000>;
+				exit-latency-us = <500>;
+			};
 		};
 
 		idle-states {
Signature · 1 line
2.25.1
maintainer
#1 lore raw

Hi Daniel,

Am Freitag, 1. Oktober 2021, 18:17:28 CEST schrieb Daniel Lezcano:

Quoted 16 lines

The thermal framework accepts now the cpu idle cooling device as an alternative when the cpufreq cooling device fails.

Add the node in the DT so the cooling devices will be present and the platforms can extend the thermal zone definition to add them.

---
 arch/arm64/boot/dts/rockchip/rk3399.dtsi | 10 ++++++++++
 1 file changed, 10 insertions(+)
arch/arm64/boot/dts/rockchip/rk3399.dtsi +0 -0
index 3871c7fd83b0..9ac232ffd284 100644

arch/arm64/boot/dts/rockchip/rk3399.dtsi cpu_b0: cpu@100 { · line 131

Quoted 8 lines
arch/arm64/boot/dts/rockchip/rk3399.dtsi +5 -0
@@ -124,6 +124,11 @@ cpu_b0: cpu@100 {
 			#cooling-cells = <2>; /* min followed by max */
 			dynamic-power-coefficient = <436>;
 			cpu-idle-states = <&CPU_SLEEP &CLUSTER_SLEEP>;
+			thermal-idle {
+				#cooling-cells = <2>;
+				duration-us = <10000>;
+				exit-latency-us = <500>;
+			};

I guess the basic question would be where do the duration and exit-latency values come from. And also what happened to cpu_l0-l3 (aka the little cores)?

Heiko

Quoted 16 lines
arch/arm64/boot/dts/rockchip/rk3399.dtsi +5 -0
 		};
 
 		cpu_b1: cpu@101 {
@@ -136,6 +141,11 @@ cpu_b1: cpu@101 {
 			#cooling-cells = <2>; /* min followed by max */
 			dynamic-power-coefficient = <436>;
 			cpu-idle-states = <&CPU_SLEEP &CLUSTER_SLEEP>;
+			thermal-idle {
+				#cooling-cells = <2>;
+				duration-us = <10000>;
+				exit-latency-us = <500>;
+			};
 		};
 
 		idle-states {
#2 lore raw

Hi Heiko,

Quoted 23 lines · Heiko Stuebner

Hi Daniel,

Am Freitag, 1. Oktober 2021, 18:17:28 CEST schrieb Daniel Lezcano:

Quoted 20 lines

The thermal framework accepts now the cpu idle cooling device as an alternative when the cpufreq cooling device fails.

Add the node in the DT so the cooling devices will be present and the platforms can extend the thermal zone definition to add them.

---
 arch/arm64/boot/dts/rockchip/rk3399.dtsi | 10 ++++++++++
 1 file changed, 10 insertions(+)
arch/arm64/boot/dts/rockchip/rk3399.dtsi +1 -0
index 3871c7fd83b0..9ac232ffd284 100644
@@ -124,6 +124,11 @@ cpu_b0: cpu@100 {
 			#cooling-cells = <2>; /* min followed by max */
 			dynamic-power-coefficient = <436>;
 			cpu-idle-states = <&CPU_SLEEP &CLUSTER_SLEEP>;
+			thermal-idle {
Quoted 8 lines

arch/arm64/boot/dts/rockchip/rk3399.dtsi cpu_b0: cpu@100 { · line 131

Quoted 4 lines
arch/arm64/boot/dts/rockchip/rk3399.dtsi +4 -0
+				#cooling-cells = <2>;
+				duration-us = <10000>;
+				exit-latency-us = <500>;
+			};

I guess the basic question would be where do the duration and exit-latency values come from. And also what happened to cpu_l0-l3 (aka the little cores)?

The duration is an arbitrary value, I've done some testing [1] to cool down the CPU.

The exit-latency is a value to ignore idle states with greater exit latency. In our case, it discards the cluster power down state.

My experiments on this platform showed the little cluster does not contribute significantly to the heat, so having idle injection is not really useful.

Just to clarify that idle injection is not better than dvfs, it can be used in addition or as a backup solution if the dvfs fails. That is the reason why there is no setup for the thermal zones.

[1] https://www.linaro.org/blog/force-idle-when-a-cpu-is-overheating/

Quoted 20 lines
Quoted 16 lines
arch/arm64/boot/dts/rockchip/rk3399.dtsi +5 -0
 		};
 
 		cpu_b1: cpu@101 {
@@ -136,6 +141,11 @@ cpu_b1: cpu@101 {
 			#cooling-cells = <2>; /* min followed by max */
 			dynamic-power-coefficient = <436>;
 			cpu-idle-states = <&CPU_SLEEP &CLUSTER_SLEEP>;
+			thermal-idle {
+				#cooling-cells = <2>;
+				duration-us = <10000>;
+				exit-latency-us = <500>;
+			};
 		};
 
 		idle-states {
Signature · 5 lines
<http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs

Follow Linaro:  <http://www.facebook.com/pages/Linaro> Facebook |
<http://twitter.com/#!/linaroorg> Twitter |
<http://www.linaro.org/linaro-blog/> Blog
maintainer Applied
#3 lore raw
In reply to Daniel Lezcano
Quoted 5 lines · Daniel Lezcano

The thermal framework accepts now the cpu idle cooling device as an alternative when the cpufreq cooling device fails.

Add the node in the DT so the cooling devices will be present and the platforms can extend the thermal zone definition to add them.

Applied, thanks!

[1/1] arm64: dts: rockchip: Add idle cooling devices

      commit: 43f9699b0c12d4e50b66723213cef456c52254f3

Best regards,

Signature · 1 line
Heiko Stuebner <[email protected]>