media: ite-cir: IR receiver stop working after receive overflow
Subsystems (3)
Sean Young
maintainerPATCH 1/1 media: ite-cir: IR receiver stop working after receive overflow
On an Intel NUC6iSYK, no IR is reported after a receive overflow.
When a receiver overflow occurs, this condition is only cleared by reading the fifo. Make sure we read anything in the fifo.
Fixes 28c7afb07ccf ("media: ite-cir: check for receive overflow")
Suggested-by Bryan Pass <[email protected]>
Tested-by Bryan Pass <[email protected]>
Signed-off-by Sean Young <[email protected]>
--- drivers/media/rc/ite-cir.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/media/rc/ite-cir.c +1 -1
@@ -242,7 +242,7 @@ static irqreturn_t ite_cir_isr(int irq, void *data) }/* check for the receive interrupt */ -if (iflags &ITE_IRQ_RX_FIFO ) { +if (iflags & (ITE_IRQ_RX_FIFO |ITE_IRQ_RX_FIFO_OVERRUN )) {/* read the FIFO bytes */ rx_bytes = dev->params->get_rx_bytes (dev, rx_buf,ITE_RX_FIFO_LEN );
Signature · 1 line