PATCH v2 1/1 mmc: dw_mmc: Allow lower TMOUT value than maximum

The TMOUT register is always set with a full value for every transfer, which (with a 200MHz clock) will give a full DRTO of ~84 milliseconds. Since the software dto_timer acts as a backup in cases when this timeout is not long enough, it is normally not a problem. But setting a full value makes it impossible to test shorter timeouts, when for example testing data read times on different SD cards.

Add a function to set any value smaller than the maximum of 0xFFFFFF.

---

v2:
- Calculate new value before checking boundaries
- Include CLKDIV register to get proper value

 drivers/mmc/host/dw_mmc.c | 32 +++++++++++++++++++++++++++++++-
 1 file changed, 31 insertions(+), 1 deletion(-)
drivers/mmc/host/dw_mmc.c +31 -1
index 6578cc64ae9e..6edd7a231448 100644
@@ -1283,6 +1283,36 @@ static void dw_mci_setup_bus(struct dw_mci_slot *slot, bool force_clkinit)
 	mci_writel(host, CTYPE, (slot->ctype << slot->id));
 }
 
+static void dw_mci_set_data_timeout(struct dw_mci *host,
+				    unsigned int timeout_ns)
+{
+	unsigned int clk_div, tmp, tmout;
+
+	clk_div = (mci_readl(host, CLKDIV) & 0xFF) * 2;
+	if (clk_div == 0)
+		clk_div = 1;
+
+	tmp = DIV_ROUND_UP_ULL((u64)timeout_ns * host->bus_hz,
+			       NSEC_PER_SEC * clk_div);
+
+	if (!tmp || tmp > 0xFFFFFF) {
+		/* Set maximum */
+		tmout = 0xFFFFFFFF;
+		goto tmout_done;
+	}
+
+	/* TMOUT[7:0] (RESPONSE_TIMEOUT) */
+	tmout = 0xFF; /* Set maximum */
+
+	/* TMOUT[31:8] (DATA_TIMEOUT) */
+	tmout |= (tmp & 0xFFFFFF) << 8;
+
+tmout_done:
+	mci_writel(host, TMOUT, tmout);
+	dev_dbg(host->dev, "timeout_ns: %u => TMOUT[31:8]: 0x%06x",
+		timeout_ns, tmout >> 8);
+}
+
 static void __dw_mci_start_request(struct dw_mci *host,
 				   struct dw_mci_slot *slot,
 				   struct mmc_command *cmd)
@@ -1303,7 +1333,7 @@ static void __dw_mci_start_request(struct dw_mci *host,
 
 	data = cmd->data;
 	if (data) {
-		mci_writel(host, TMOUT, 0xFFFFFFFF);
+		dw_mci_set_data_timeout(host, data->timeout_ns);
 		mci_writel(host, BYTCNT, data->blksz*data->blocks);
 		mci_writel(host, BLKSIZ, data->blksz);
 	}
Signature · 1 line
2.20.1
maintainer
#1 lore raw

Hi Marten,

Quoted 31 lines · Mårten Lindahl

The TMOUT register is always set with a full value for every transfer, which (with a 200MHz clock) will give a full DRTO of ~84 milliseconds. Since the software dto_timer acts as a backup in cases when this timeout is not long enough, it is normally not a problem. But setting a full value makes it impossible to test shorter timeouts, when for example testing data read times on different SD cards.

Add a function to set any value smaller than the maximum of 0xFFFFFF.

---

v2:
- Calculate new value before checking boundaries
- Include CLKDIV register to get proper value

 drivers/mmc/host/dw_mmc.c | 32 +++++++++++++++++++++++++++++++-
 1 file changed, 31 insertions(+), 1 deletion(-)
drivers/mmc/host/dw_mmc.c +4 -0
index 6578cc64ae9e..6edd7a231448 100644
@@ -1283,6 +1283,36 @@ static void dw_mci_setup_bus(struct dw_mci_slot *slot, bool force_clkinit)
 	mci_writel(host, CTYPE, (slot->ctype << slot->id));
 }
 
+static void dw_mci_set_data_timeout(struct dw_mci *host,
+				    unsigned int timeout_ns)
+{
+	unsigned int clk_div, tmp, tmout;

drivers/mmc/host/dw_mmc.c static void dw_mci_setup_bus(struct dw_mci_slot *slot, bool force_clkinit) · line 1299

Quoted 10 lines
drivers/mmc/host/dw_mmc.c +10 -0
+
+	clk_div = (mci_readl(host, CLKDIV) & 0xFF) * 2;
+	if (clk_div == 0)
+		clk_div = 1;
+
+	tmp = DIV_ROUND_UP_ULL((u64)timeout_ns * host->bus_hz,
+			       NSEC_PER_SEC * clk_div);
+
+	if (!tmp || tmp > 0xFFFFFF) {
+		/* Set maximum */

"Set maximum value about all Timeout"?

drivers/mmc/host/dw_mmc.c static void dw_mci_setup_bus(struct dw_mci_slot *slot, bool force_clkinit) · line 1302

Quoted 3 lines
drivers/mmc/host/dw_mmc.c +3 -0
+		tmout = 0xFFFFFFFF;
+		goto tmout_done;
+	}

It doesn't need to use "goto". Instead, if-else can be used.

drivers/mmc/host/dw_mmc.c static void dw_mci_setup_bus(struct dw_mci_slot *slot, bool force_clkinit) · line 1305

Quoted 3 lines
drivers/mmc/host/dw_mmc.c +3 -0
+
+	/* TMOUT[7:0] (RESPONSE_TIMEOUT) */
+	tmout = 0xFF; /* Set maximum */

To prevent a confusion, how about add "Set a maximum response timeout" And this line can be removed.

drivers/mmc/host/dw_mmc.c static void dw_mci_setup_bus(struct dw_mci_slot *slot, bool force_clkinit) · line 1308

Quoted 3 lines
drivers/mmc/host/dw_mmc.c +3 -0
+
+	/* TMOUT[31:8] (DATA_TIMEOUT) */
+	tmout |= (tmp & 0xFFFFFF) << 8;

tmout = (0xFF | ((tmp & 0xFFFFFF) << 8));

The entire code can be below

if (!tmp || ....)

	tmout = 0xFFFFFFFF;
else 
	tmout = (0xFF | ((tmp & 0xFFFFFF) << 8));

writel(TMOUT, ...)

How about this?

Best Regards,
Jaehoon Chung

Quoted 20 lines
drivers/mmc/host/dw_mmc.c +8 -1
+
+tmout_done:
+	mci_writel(host, TMOUT, tmout);
+	dev_dbg(host->dev, "timeout_ns: %u => TMOUT[31:8]: 0x%06x",
+		timeout_ns, tmout >> 8);
+}
+
 static void __dw_mci_start_request(struct dw_mci *host,
 				   struct dw_mci_slot *slot,
 				   struct mmc_command *cmd)
@@ -1303,7 +1333,7 @@ static void __dw_mci_start_request(struct dw_mci *host,
 
 	data = cmd->data;
 	if (data) {
-		mci_writel(host, TMOUT, 0xFFFFFFFF);
+		dw_mci_set_data_timeout(host, data->timeout_ns);
 		mci_writel(host, BYTCNT, data->blksz*data->blocks);
 		mci_writel(host, BLKSIZ, data->blksz);
 	}
#2 lore raw
Quoted 1 line · Jaehoon Chung

Hi Marten,

Hi Jaehoon!

Quoted 29 lines · Mårten Lindahl
Quoted 27 lines

The TMOUT register is always set with a full value for every transfer, which (with a 200MHz clock) will give a full DRTO of ~84 milliseconds. Since the software dto_timer acts as a backup in cases when this timeout is not long enough, it is normally not a problem. But setting a full value makes it impossible to test shorter timeouts, when for example testing data read times on different SD cards.

Add a function to set any value smaller than the maximum of 0xFFFFFF.

---

v2:
- Calculate new value before checking boundaries
- Include CLKDIV register to get proper value

 drivers/mmc/host/dw_mmc.c | 32 +++++++++++++++++++++++++++++++-
 1 file changed, 31 insertions(+), 1 deletion(-)
drivers/mmc/host/dw_mmc.c +0 -0
index 6578cc64ae9e..6edd7a231448 100644
@@ -1283,6 +1283,36 @@ static void dw_mci_setup_bus(struct dw_mci_slot *slot, bool force_clkinit)
 	mci_writel(host, CTYPE, (slot->ctype << slot->id));
 }
 
Quoted 16 lines
Quoted 4 lines
drivers/mmc/host/dw_mmc.c +4 -0
+static void dw_mci_set_data_timeout(struct dw_mci *host,
+				    unsigned int timeout_ns)
+{
+	unsigned int clk_div, tmp, tmout;

drivers/mmc/host/dw_mmc.c static void dw_mci_setup_bus(struct dw_mci_slot *slot, bool force_clkinit) · line 1299

Quoted 10 lines
drivers/mmc/host/dw_mmc.c +10 -0
+
+	clk_div = (mci_readl(host, CLKDIV) & 0xFF) * 2;
+	if (clk_div == 0)
+		clk_div = 1;
+
+	tmp = DIV_ROUND_UP_ULL((u64)timeout_ns * host->bus_hz,
+			       NSEC_PER_SEC * clk_div);
+
+	if (!tmp || tmp > 0xFFFFFF) {
+		/* Set maximum */

"Set maximum value about all Timeout"?

Do you mean just changing the comment here? Or do you wonder about the 0xFFFFFF check? 0xFFFFFF is the upper limit for this HW timer. If we want to support a longer timer than this, a software timer should be used, but in a separate patch.

Quoted 6 lines

drivers/mmc/host/dw_mmc.c static void dw_mci_setup_bus(struct dw_mci_slot *slot, bool force_clkinit) · line 1302

Quoted 4 lines
drivers/mmc/host/dw_mmc.c +3 -0
+		tmout = 0xFFFFFFFF;
+		goto tmout_done;
+	}

It doesn't need to use "goto". Instead, if-else can be used.

If you prefer it I can change goto to if-else

Quoted 7 lines

drivers/mmc/host/dw_mmc.c static void dw_mci_setup_bus(struct dw_mci_slot *slot, bool force_clkinit) · line 1305

Quoted 4 lines
drivers/mmc/host/dw_mmc.c +3 -0
+
+	/* TMOUT[7:0] (RESPONSE_TIMEOUT) */
+	tmout = 0xFF; /* Set maximum */

To prevent a confusion, how about add "Set a maximum response timeout" And this line can be removed.

But if removing the lines above, the comment will also be removed. I see your point, but couldn't there be more confusion by merging both fields into one line? My intention was to specify the TMOUT register fields separately to make it more clear.

Quoted 9 lines

drivers/mmc/host/dw_mmc.c static void dw_mci_setup_bus(struct dw_mci_slot *slot, bool force_clkinit) · line 1308

Quoted 4 lines
drivers/mmc/host/dw_mmc.c +3 -0
+
+	/* TMOUT[31:8] (DATA_TIMEOUT) */
+	tmout |= (tmp & 0xFFFFFF) << 8;

tmout = (0xFF | ((tmp & 0xFFFFFF) << 8));

The entire code can be below

Quoted 8 lines

if (!tmp || ....)

	tmout = 0xFFFFFFFF;
else 
	tmout = (0xFF | ((tmp & 0xFFFFFF) << 8));

writel(TMOUT, ...)

How about this?

I agree that this is smaller code, but as I said above it may not be clear that there are more than one field in the TMOUT register. Wouldn't it raise questions about the 0xFF?

Kind regards
Mårten

Quoted 25 lines

Best Regards,
Jaehoon Chung

Quoted 20 lines
drivers/mmc/host/dw_mmc.c +8 -1
+
+tmout_done:
+	mci_writel(host, TMOUT, tmout);
+	dev_dbg(host->dev, "timeout_ns: %u => TMOUT[31:8]: 0x%06x",
+		timeout_ns, tmout >> 8);
+}
+
 static void __dw_mci_start_request(struct dw_mci *host,
 				   struct dw_mci_slot *slot,
 				   struct mmc_command *cmd)
@@ -1303,7 +1333,7 @@ static void __dw_mci_start_request(struct dw_mci *host,
 
 	data = cmd->data;
 	if (data) {
-		mci_writel(host, TMOUT, 0xFFFFFFFF);
+		dw_mci_set_data_timeout(host, data->timeout_ns);
 		mci_writel(host, BYTCNT, data->blksz*data->blocks);
 		mci_writel(host, BLKSIZ, data->blksz);
 	}
maintainer
#3 lore raw
Quoted 51 lines · Marten Lindahl
Quoted 1 line · Jaehoon Chung

Hi Marten,

Hi Jaehoon!

Quoted 29 lines · Mårten Lindahl
Quoted 27 lines

The TMOUT register is always set with a full value for every transfer, which (with a 200MHz clock) will give a full DRTO of ~84 milliseconds. Since the software dto_timer acts as a backup in cases when this timeout is not long enough, it is normally not a problem. But setting a full value makes it impossible to test shorter timeouts, when for example testing data read times on different SD cards.

Add a function to set any value smaller than the maximum of 0xFFFFFF.

---

v2:
- Calculate new value before checking boundaries
- Include CLKDIV register to get proper value

 drivers/mmc/host/dw_mmc.c | 32 +++++++++++++++++++++++++++++++-
 1 file changed, 31 insertions(+), 1 deletion(-)
drivers/mmc/host/dw_mmc.c +0 -0
index 6578cc64ae9e..6edd7a231448 100644
@@ -1283,6 +1283,36 @@ static void dw_mci_setup_bus(struct dw_mci_slot *slot, bool force_clkinit)
 	mci_writel(host, CTYPE, (slot->ctype << slot->id));
 }
 
Quoted 16 lines
Quoted 4 lines
drivers/mmc/host/dw_mmc.c +4 -0
+static void dw_mci_set_data_timeout(struct dw_mci *host,
+				    unsigned int timeout_ns)
+{
+	unsigned int clk_div, tmp, tmout;

drivers/mmc/host/dw_mmc.c static void dw_mci_setup_bus(struct dw_mci_slot *slot, bool force_clkinit) · line 1299

Quoted 10 lines
drivers/mmc/host/dw_mmc.c +10 -0
+
+	clk_div = (mci_readl(host, CLKDIV) & 0xFF) * 2;
+	if (clk_div == 0)
+		clk_div = 1;
+
+	tmp = DIV_ROUND_UP_ULL((u64)timeout_ns * host->bus_hz,
+			       NSEC_PER_SEC * clk_div);
+
+	if (!tmp || tmp > 0xFFFFFF) {
+		/* Set maximum */

"Set maximum value about all Timeout"?

Quoted 4 lines

Do you mean just changing the comment here? Or do you wonder about the 0xFFFFFF check? 0xFFFFFF is the upper limit for this HW timer. If we want to support a longer timer than this, a software timer should be used, but in a separate patch.

My mean is how about changing the comment to clarify than now. At below, tmout is set to maximum value about data/response timeout.

Quoted 9 lines
Quoted 7 lines

drivers/mmc/host/dw_mmc.c static void dw_mci_setup_bus(struct dw_mci_slot *slot, bool force_clkinit) · line 1302

Quoted 5 lines
drivers/mmc/host/dw_mmc.c +3 -0
+		tmout = 0xFFFFFFFF;
+		goto tmout_done;
+	}

It doesn't need to use "goto". Instead, if-else can be used.

If you prefer it I can change goto to if-else

Well, it's just my preference. If you're ok, I hope that so.

Quoted 9 lines
Quoted 8 lines

drivers/mmc/host/dw_mmc.c static void dw_mci_setup_bus(struct dw_mci_slot *slot, bool force_clkinit) · line 1305

Quoted 5 lines
drivers/mmc/host/dw_mmc.c +3 -0
+
+	/* TMOUT[7:0] (RESPONSE_TIMEOUT) */
+	tmout = 0xFF; /* Set maximum */

To prevent a confusion, how about add "Set a maximum response timeout" And this line can be removed.

Quoted 4 lines

But if removing the lines above, the comment will also be removed. I see your point, but couldn't there be more confusion by merging both fields into one line? My intention was to specify the TMOUT register fields separately to make it more clear.

Agreed. It's more clear than my opinion.

Best Regards,
Jaehoon Chung

Quoted 52 lines
Quoted 10 lines

drivers/mmc/host/dw_mmc.c static void dw_mci_setup_bus(struct dw_mci_slot *slot, bool force_clkinit) · line 1308

Quoted 5 lines
drivers/mmc/host/dw_mmc.c +3 -0
+
+	/* TMOUT[31:8] (DATA_TIMEOUT) */
+	tmout |= (tmp & 0xFFFFFF) << 8;

tmout = (0xFF | ((tmp & 0xFFFFFF) << 8));

The entire code can be below

Quoted 8 lines

if (!tmp || ....)

	tmout = 0xFFFFFFFF;
else 
	tmout = (0xFF | ((tmp & 0xFFFFFF) << 8));

writel(TMOUT, ...)

How about this?

I agree that this is smaller code, but as I said above it may not be clear that there are more than one field in the TMOUT register. Wouldn't it raise questions about the 0xFF?

Kind regards
Mårten

Quoted 25 lines

Best Regards,
Jaehoon Chung

Quoted 20 lines
drivers/mmc/host/dw_mmc.c +8 -1
+
+tmout_done:
+	mci_writel(host, TMOUT, tmout);
+	dev_dbg(host->dev, "timeout_ns: %u => TMOUT[31:8]: 0x%06x",
+		timeout_ns, tmout >> 8);
+}
+
 static void __dw_mci_start_request(struct dw_mci *host,
 				   struct dw_mci_slot *slot,
 				   struct mmc_command *cmd)
@@ -1303,7 +1333,7 @@ static void __dw_mci_start_request(struct dw_mci *host,
 
 	data = cmd->data;
 	if (data) {
-		mci_writel(host, TMOUT, 0xFFFFFFFF);
+		dw_mci_set_data_timeout(host, data->timeout_ns);
 		mci_writel(host, BYTCNT, data->blksz*data->blocks);
 		mci_writel(host, BLKSIZ, data->blksz);
 	}