The issue happened randomly in runtime. The message "Link is Down" is popped but soon it recovered to "Link is Up".
The "Link is Down" results from the incorrect read data for reading the PHY register via MDIO bus. The correct sequence for reading the data shall be:
1. fire the command
2. wait for command done (this step was missing)
3. wait for data idle
4. read data from data register
---
v2: revise commit message
drivers/net/mdio/mdio-aspeed.c | 7 +++++++ 1 file changed, 7 insertions(+)
drivers/net/mdio/mdio-aspeed.c +7 -0
@@ -61,6 +61,13 @@ static int aspeed_mdio_read(struct mii_bus *bus, int addr, int regnum)iowrite32 (ctrl, ctx->base +ASPEED_MDIO_CTRL ); + rc =readl_poll_timeout (ctx->base +ASPEED_MDIO_CTRL , ctrl, + !(ctrl &ASPEED_MDIO_CTRL_FIRE ), +ASPEED_MDIO_INTERVAL_US , +ASPEED_MDIO_TIMEOUT_US ); +if (rc <0 ) +return rc; + rc = readl_poll_timeout(ctx->base + ASPEED_MDIO_DATA, data, data & ASPEED_MDIO_DATA_IDLE, ASPEED_MDIO_INTERVAL_US,
Signature · 1 line
2.25.1
Quoted 11 lines · Dylan Hung
The issue happened randomly in runtime. The message "Link is Down" is popped but soon it recovered to "Link is Up".
The "Link is Down" results from the incorrect read data for reading the PHY register via MDIO bus. The correct sequence for reading the data shall be:
1. fire the command
2. wait for command done (this step was missing)
3. wait for data idle
4. read data from data register
Quoted 4 lines
Fixes f160e99462c6 ("net: phy: Add mdio-aspeed")Reviewed-by Joel Stanley <[email protected]>Signed-off-by Dylan Hung <[email protected]>
_______________________________________________
linux-arm-kernel mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel
Quoted 11 lines · Dylan Hung
The issue happened randomly in runtime. The message "Link is Down" is popped but soon it recovered to "Link is Up".
The "Link is Down" results from the incorrect read data for reading the PHY register via MDIO bus. The correct sequence for reading the data shall be:
1. fire the command
2. wait for command done (this step was missing)
3. wait for data idle
4. read data from data register
Quoted 4 lines
Fixes f160e99462c6 ("net: phy: Add mdio-aspeed")Cc stable at vger.kernel.orgReviewed-by Joel Stanley <[email protected]>Signed-off-by Dylan Hung <[email protected]>
Andrew
Quoted 11 lines · Dylan Hung
The issue happened randomly in runtime. The message "Link is Down" is popped but soon it recovered to "Link is Up".
The "Link is Down" results from the incorrect read data for reading the PHY register via MDIO bus. The correct sequence for reading the data shall be:
1. fire the command
2. wait for command done (this step was missing)
3. wait for data idle
4. read data from data register
Quoted 4 lines
Fixes f160e99462c6 ("net: phy: Add mdio-aspeed")Cc stable at vger.kernel.orgReviewed-by Joel Stanley <[email protected]>Signed-off-by Dylan Hung <[email protected]>
Thanks.
Signature · 2 lines
RMK's Patch system: https://www.armlinux.org.uk/developer/patches/ FTTP is here! 40Mbps down 10Mbps up. Decent connectivity at last!
This patch was applied to netdev/net.git (master) by Jakub Kicinski <[email protected]>:
Hello:
This patch was applied to netdev/net.git (master)
by Jakub Kicinski <[email protected]>:
Quoted 11 lines · On Thu, 25 Nov 2021 10:44:32 +0800 you wrote:
The issue happened randomly in runtime. The message "Link is Down" is popped but soon it recovered to "Link is Up".
The "Link is Down" results from the incorrect read data for reading the PHY register via MDIO bus. The correct sequence for reading the data shall be:
1. fire the command
2. wait for command done (this step was missing)
3. wait for data idle
4. read data from data register
Quoted 1 line
[...]
Here is the summary with links:
- [v2] mdio: aspeed: Fix "Link is Down" issue
https://git.kernel.org/netdev/net/c/9dbe33cf371b
You are awesome, thank you!
Signature · 2 lines
Deet-doot-dot, I am a bot. https://korg.docs.kernel.org/patchwork/pwbot.html