Skip to contentSkip to conversation

power: supply: axp20x_battery: properly report current when discharging

PATCH In review Evgeny Boger 2 participants 2 messages Jan 12, 2022 – Jan 13, 2022

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH v2 1/1 power: supply: axp20x_battery: properly report current when discharging

As stated in [1], negative current values are used for discharging batteries.

AXP PMICs internally have two different ADC channels for shunt current
measurement: one used during charging and one during discharging. The values reported by these ADCs are unsigned.
While the driver properly selects ADC channel to get the data from, it doesn't apply negative sign when reporting discharging current.

[1] Documentation/ABI/testing/sysfs-class-power

---
Changes from v1:
* fix formatting, no other changes

 drivers/power/supply/axp20x_battery.c | 13 ++++++-------
 1 file changed, 6 insertions(+), 7 deletions(-)
drivers/power/supply/axp20x_battery.c +6 -7
index 5d197141f476..9106077c0dbb 100644
@@ -186,7 +186,6 @@ static int axp20x_battery_get_prop(struct power_supply *psy,
 				   union power_supply_propval *val)
 {
 	struct axp20x_batt_ps *axp20x_batt = power_supply_get_drvdata(psy);
-	struct iio_channel *chan;
 	int ret = 0, reg, val1;
 
 	switch (psp) {
@@ -266,12 +265,12 @@ static int axp20x_battery_get_prop(struct power_supply *psy,
 		if (ret)
 			return ret;
 
-		if (reg & AXP20X_PWR_STATUS_BAT_CHARGING)
-			chan = axp20x_batt->batt_chrg_i;
-		else
-			chan = axp20x_batt->batt_dischrg_i;
-
-		ret = iio_read_channel_processed(chan, &val->intval);
+		if (reg & AXP20X_PWR_STATUS_BAT_CHARGING) {
+			ret = iio_read_channel_processed(axp20x_batt->batt_chrg_i, &val->intval);
+		} else {
+			ret = iio_read_channel_processed(axp20x_batt->batt_dischrg_i, &val1);
+			val->intval = -val1;
+		}
 		if (ret)
 			return ret;
 
Signature · 1 line
2.25.1
Acked-by on v2 1/1
#1 lore raw
Quoted 10 lines · Evgeny Boger

As stated in [1], negative current values are used for discharging batteries.

AXP PMICs internally have two different ADC channels for shunt current
measurement: one used during charging and one during discharging. The values reported by these ADCs are unsigned.
While the driver properly selects ADC channel to get the data from, it doesn't apply negative sign when reporting discharging current.

Quoted 3 lines

[1] Documentation/ABI/testing/sysfs-class-power